Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

Similar documents
4766 Research Dr. San Antonio, TX insightdentalsystems.com

Smarter Thinking. Simpler Design. STAGE-1. Surgical Manual

INTRODUCTION. General Information. Important Warning

Clinical Perspectives

The Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly.

Instructions for Use DENTAL IMPLANTS

INTERNAL HEX Implant System

IOS & The Sirona Connect System Clinician Procedure

SimpleLine II Surgical / Prosthesis Manual

Legacy Prosthetic Catalog

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

NARROW DIAMETER implant

Guided surgery manual

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

Instructions for Use for dental implant

NEODENT GUIDED SURGERY

Case Study. Case # 1 Author: Dr. Suheil Boutros (USA) 2013 Zimmer Dental, Inc. All rights reserved. 6557, Rev. 03/13.

GMI FRONTIER implant system. Surgical procedures guide

SURGICAL MANUAL. Step By Step Techniques

NARROW DIAMETER implant

GMI. MONOLITH implant system. Surgical procedures guide

NobelActive. Quick start page 5. Surgical procedures page 8. Prosthetic procedures page 28. Appendix IV cleaning and. sterilization page 66

Astra Tech Implant System. Manual and product catalog. Guided surgery. Computer guided implant treatment with the Astra Tech Implant System EV

- RESTORATIVE PRODUCT CATALOG

SwissPlant Prosthetic Catalog. SwissPlant

Conventus CAGE PH Surgical Techniques

Surgical Manual. Spline Implant System

Surgical Manual. Step By Step Techniques

Implant Mountless Package Handling. Instructions for Use

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Osseointegrated dental implant treatment generally

Zimmer Biomet Instrument Kit System

Smarter Thinking. Simpler Design. TILOBEMAXX TM. Product Catalog

Navigator System Model-Based Surgery Manual

Trefoil Procedure manual

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

Biomimetic Product catalogue

CONTENTS. Introduction to DASK. Crestal Approach. Lateral Approach

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

Zimmer Biomet Instrument Kit System

Immediate Loading with Flapless Implant Surgery for Rehabilitation of Single Bound Edentulous Space

Astra Tech Implant System. Surgical manual. OsseoSpeed TX

Hex-Lock Abutment System. Restorative Manual

C O N T E N T S. Introduction of DASK. Crestal Approach. Lateral Approach. Dentium - For Dentists By Dentists

PROSTHETIC COMPONENTS

Neoss Implant System Guidelines

High-end solution STEP-BY-STEP USER GUIDE

TRINON. Index. Index. Overview Page 4. Catalogue

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

Extraction with Immediate Implant Placement and Ridge Preservation in the Posterior

Instructions for Use DENTAL IMPLANTS

Basic Information on Straumann Guided Surgery. Straumann Dental Implant System

SuperLine & Implantium Surgical / Prosthesis Manual

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Including product catalog

Smarter Thinking. Simpler Design. Prima TM. Product Catalog

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

Astra Tech Implant System. Surgical manual. Astra Tech Implant System EV

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

DASK-0912 [Rev.3] Distributed by. DASK_rev3_1127: 레이아웃 오? 4:53 페이지 1. Specifications are subject to change without prior notice.

Replacement of missing teeth with

Neoss Implant System Guidelines

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

SURGICAL PROCEDURES FOR ROXOLID IMPLANTS

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Ankylos. Acuris conometric concept. Manual and product catalog

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

Product Catalog July 2017

Implant System MAKE IT SIMPLE

Surgical Manual July 2017

Where technology meets dentistry INNOVATION. at a GLANCE

27030 Malibu Hills Road, Calabasas Hills, CA USA voice, fax,

MINI IMPLANT SYSTEM English Instructions for Use MINI IMPLANTS

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

Restoring Straumann implants. with Locator abutments.

Fixed Restoration for Atrophic Ridges

Product Catalog August 2018

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL QUATTROCONE QUATTROCONE30. IPS Implant systems

SURGICAL TECHNIQUE GUIDE

EasyLineImplant. Guided Surgery

INTRODUCTION TO THE BICON SYSTEM

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

Straumann Dental Implant System. Fax Order Form Collection.*

Introduction of Dentium Implant. Help kit

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

SURGICAL MANUAL GRAND MORSE

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

SuperLine & Implantium Surgical / Prosthesis Manual

Guided surgery with NobelParallel Conical Connection Product overview

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Product Catalog. Since 1985» Simple. Predictable. Profitable.

Product Catalog. Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients.

Transcription:

Smarter Thinking. Simpler Design. Prima Plus Surgical Manual

TABLE OF CONTENTS PRIMA PLUS IMPLANT SURGICAL MANUAL SURGERY Prima Plus Characteristics 4 Surgical Considerations 5 Prima Plus Surgical Sequence 9 Depth Markings 11 Drilling Sequences 12 Product specifications are subject to change without notice. Items illustrated are not to scale. 2 3

PRIMA PLUS CHARACTERISTICS SURGICAL CONSIDERATIONS Design Features The Prima Plus dental implant features the Ti-Lobe connection. This internal 6-lobe connection combines the benefits of a platform switch, internal lobed design, and integrated pilot (self-alignment feature), providing a secure implant/abutment connection. This design allows for one screw for all platform diameters. 3.5 3.8 8.5 Taper 6-Lobe Connection Pilot 3.5 4.1 5.0 3.5 4.1 5.0 Dimensions The Ø3.5 mm Prima Plus implants can be restored with either 4.0 mm or 5.0 mm prosthetic components. The Ø4.1 mm Prima Plus implants can be restored with either 5.0 mm or 6.0 mm prosthetic components. The Ø5.0/6.0 Prima Plus implants share the same connection and can be restored with either a 6.0 mm prosthetic component or a Ø7.0 and Ø8.0 mm Healing Abutment. 3.5 4.1 3.5 4.1 5.0 3.5 4.1 5.0 6.0 The Ø3.5 mm Prima Plus implants are available in 8.0, 10.0, 11.5, 13, 15 mm lengths. The Ø4.1 mm Prima Plus implants are available in 8.0, 10.0, 11.5, 13, 15 mm lengths. The Ø5.0 mm Prima Plus implants are available in 8.0, 10.0, 11.5, 13, 15 mm lengths. The Ø6.0 mm Prima Plus implants are available in 8.0, 10.0, 11.5, and 13 mm lengths. Considerations INDICATIONS Keystone Dental Prima Plus implants are intended for use in partially or fully edentulous mandibles and maxillae, in support of single or multiple-unit restorations including cement-retained, screw-retained, or overdenture restorations, and terminal or intermediate abutment support for fixed bridgework. SPECIFIC INTENDED USES Prima Plus Internal Connection Implants are threaded, internal connection implants intended for immediate placement and can be restored with a temporary prosthesis in single- tooth and multiple- tooth applications with good quality bone. CONTRAINDICATIONS General contraindications associated with elective surgery should be observed Possible contraindications: chronic bleeding problems, psychological impairment, metabolic bone or connective tissue diseases, treatment with corticosteriods, certain cardiac and vascular diseases, tobacco usage, diabetes (uncontrolled), treatment with chemotherapeutic agents, chronic renal disease, poor patient oral hygiene, bruxing, alcoholism Temporary contraindications: systemic infection; local oral or respiratory infection Anatomical or pathological contraindications: insufficient alveolar bone width and height to surround the implant with at least one millimeter of bone, both buccally and lingually to the most superior aspect of the implant body; inadequate bone height where proper implant placement would encroach on the mandibular canal; malignancies For additional information, please consult the Keystone Dental Prima Plus Implant Instructions for Use. SOFT TISSUE HEALING AND TEMPORIZATION Following the placement of a Prima Plus implant, soft tissue can be contoured using a titanium Healing Abutment or a custom fabricated temporary abutment. A Temporary Abutment can be placed at this time for immediate temporization. The acrylic portion of the Temporary Abutment bonds with dental composite/acrylic allowing for custom esthetic contouring directly to the Temporary Abutment. PATIENT EVALUATION AND SELECTION Successful implant treatment requires the coordinated efforts of the implanting surgeon, the restorative dentist, and the dental laboratory technician. Proper patient selection is important for long-term function of a dental implant. The following factors should be considered prior to implant surgery: General medical history Oral hygiene Patient s expectations General dentistry and product indications and contraindications Anatomical landmarks related to implant positioning Inter-occlusal clearance (the space available between alveolar crest and opposing dentition) Ridge width in relation to the implant diameter Emergence profile of the restoration in relation to prosthetic platform diameters BONE QUALITY While one method of classifying bone density is shown in the images below, different combinations of cortical and trabecular bone in varying thicknesses and densities can occur. These typically differ by jaw location. The clinician is responsible for assessing bone density of the surgical site and choosing the appropriate protocol. D1 Bone Cortical bone D2 Bone Cortical bone/ trabecular D3 Bone Cortical bone/ trabecular D4 Bone Cortical bone/ trabecular 4 5

SURGICAL CONSIDERATIONS SURGICAL CONSIDERATIONS Surgical Guide Surgical Kit Drilling and Tapping Procedures Available planning software provides both clinicians and technicians the ability to plan implant placement three-dimensionally in conjunction with CT scans. A surgical guide could aid in the site preparation and placement of implants. Implant Selection Implant selection should be made with the final restorative result as the primary consideration. Selecting implants in this manner aids in maximizing biomechanical stability and proper contouring of the soft tissue. Choosing an implant with a slightly smaller platform than the emergence of the tooth being replaced will provide support of the soft tissue and optimize the esthetic result. Implant placement and healing abutment selections should be based on the following: Emergence profile of the restoration in relation to the prosthetic platform diameter Height and diameter of the crown as it emerges through the tissue Multiple-part instruments must be disassembled prior to cleaning and sterilization. Internal debris/residue of instruments must be removed with a soft brush. Instruments should be inspected, cleaned separately and discarded if damaged. PRINCIPAL CLEANING Best results are achieved if surgical instruments are cleaned by material type. Instruments and trays can be cleaned and disinfected in a dedicated dishwasher or alternatively by hand, followed by an ultrasonic bath with a detergent appropriate for surgical instruments. Instruments and trays must be rinsed and dried thoroughly. STERILIZATION The Surgical Kit must be cleaned and sterilized prior to use. For further information, please consult Keystone Dental s Instructions for Use. All surgical instruments are provided non-sterile. All Prima Plus drills are externally irrigated and require external irrigation when preparing the osteotomy. All drills must be inspected for signs of wear, damage or discoloration. The drills are labeled with a diameter to facilitate proper instrument selection. It is recommended to inspect the latch-lock shank after each use. The number of uses per drill will vary and depends on a variety of factors including bone density, proper handling and cleaning. It is recommended to replace drills after 20 osteotomies, as repeated sterilizations and use may affect cutting efficiency and depth marking appearance. Soft bone considerations: The end-cutting capabilities of Prima Plus TM allows it to be inserted into sites that have been prepared with a reduced diameter drill (see drilling protocol on page 12). When the implant is inserted, the end-cutting features will aid in guiding the implant to the final depth. Dense bone considerations: Utilizing the end-cutting feature to seat the implant should not be attempted in dense bone. Surgical taps should be used when the recommended surgical protocol (see drilling protocol on page 12) is not sufficient to fully seat the implant or insertion torques are higher than 70Ncm. It is recommended to avoid lateral pressure during drilling and tapping procedures as the resulting osteotomy may be oversized and/ or redirected. When using the Twist Step drills, it is recommended to use an in-andout technique when preparing the site. Recommended drill speeds are 1200-1500 rpm. When tapping, the top of the tap should correspond to the height of the implant platform, regardless of implant length. Instrument Care Instruments must be cleaned and sterilized prior to first and after each use based on established procedures. Proper instrument care is an important part of successful implant dentistry. PRE-CLEANING Used instruments should be soaked immediately in instrument cleaning solution to avoid the drying of blood, saliva and tissue residue. Used surgical trays including grommets must be cleaned with a suitable disinfectant. Instruments and tray should be autoclaved with a sufficient drying cycle to avoid instrument corrosion. Instruments should be placed in the tray and wrapped in sterilization paper or sterilization packs featuring indicating tape and date of sterilization. Steam Sterilization Gravity Cycle: 134 C (~273 F) 20 minute exposure / 40 minute dry time Steam Sterilization Pre Vacuum Cycle: 134 C (~273 F) 4 minute exposure / 40 minute dry time SURGICAL MOTOR AND HANDPIECE Cleaning and maintenance instructions for W&H handpieces and motors can be found on www.wh.com. (-) Denotes widening of the crestal bone is recommended. Ø4.1 x 11.5mm 6 7

SURGICAL PRIMA PLUSTM CONSIDERATIONS SURGICAL SEQUENCE Surgical Sequence Prima Plus Ø4.1 mm x 11.5 mm (For demonstration purposes) Implant Packaging Implant Delivery For additional drilling protocols by bone density please see page 12. Prima Plus implants are delivered to the osteotomy with an Implant Driver. Each Prima Plus implant is packaged in a vial, sealed in a tray with a Tyvek lid and gamma-sterilized. The flip-open lid on the vial contains a cover screw. The sealed tray contains a label identifying the implant type, diameter and length, as well as other important device information. Inside, pre-printed patient labels with product data and the lot number are provided. These are adhesive labels that should be affixed to the patient s chart. Soft Bone NOTE: Drill dimensions in brackets denote that widening of the crestal bone for insertion torques above 70Ncm is recommended. The Implant Driver is aligned with the implant. While pressure is applied, the Implant Driver is rotated at a speed less than 20 rpm until the lobes of the Implant Driver engage the implant lobes. A tactile and/or audible click may occur indicating the Implant Driver is engaged. The implant is lifted out of the vial and placed into the osteotomy. Opening instructions: NOTE: When correctly seated, the laser mark on the driver should be below the platform of the implant and not visible. 1. The Tyvek lid on the tray is peeled back and placed into the sterile field. 2. The patient labels are affixed to the patient s chart. 3. The implant lid is flipped open to gain access to the selected Prima Plus implant. 1.8 mm Initial Drill x 11.5 mm The implant may now be removed from the vial, delivered to the site and placed using one of the following options. Parallel Pin/Depth Gauge 11.5 mm 2.2/2.6 mm Twist Step Drill Medium Bone Disengaged (2.6/2.9) mm Twist Step Drill (It is not recommended to drill to full depth). Engaged The Implant Driver is pulled straight up to disengage the Implant Driver from the implant. Special care should be taken in very soft bone to not disrupt primary stability. 1.8 mm Initial Drill x 11.5 mm Implant Placement Parallel Pin/Depth Gauge 11.5 mm 2.2/2.6 mm Twist Step Drill Parallel Pin/Depth Gauge 11.5 mm 2.2/2.6 mm Twist Step Drill 2.9/3.3 mm Twist Step Drill Dense Bone The final implant position is at the discretion of the surgeon. Each case should be evaluated on the basis of placement, protocol and type of implant prior to osteotomy preparation. It is recommended to place a Prima Plus implant at bone level. 1.8 mm Initial Drill x 11.5 mm 8 9 2.9/3.3 mm Twist Step Drill (3.4/3.9 mm) Twist Step Drill (It is not recommended to drill to full depth).

PRIMA PLUSTM PRIMA PLUS SURGICAL SEQUENCE DEPTH MARKINGS PRIMA PLUSTM IMPLANT POSITIONING If the treatment plan includes using anatomically- shaped abutments such as the angled or straight Esthetic Contour Abutments, the rotational position of the implant can be adjusted at the time of placement to ensure optimal positioning of the final abutment. This will allow the restoring clinician to take full advantage of the anatomical abutment contours and minimize the need for abutment prepping. If the clinical situation allows, adjust the final position of the implant so that any one of the six internal connection lobes faces the buccal or facial aspect. Prima Plus Drilling Sequence - 4.1 x 11.5 mm in Medium Bone The Prima Plus Twist Step drills feature the following laser markings: Step 6 Handpiece Insertion - Prima PlusTM Ratchet Insertion - Prima PlusTM With the Implant Driver connected to the handpiece, the internal lobes are fully engaged by the Implant Driver and carefully removed from the vial. It is then carried to the osteotomy and inserted at 15-20 rpm. The Surgical Ratchet can be used in addition to or instead of a handpiece to finalize the insertion of the implant by engaging the Implant Driver into the Ratchet with the Ratchet Adapter. Laser mark represents implant length + over drill length Diameter and length of drill is identified on the shaft The actual drill tip is not included in the designated drill length and must be considered when preparing the osteotomy. Implant Length 15 mm 13 mm 11.5 mm 10 mm 8 mm Bone Level Over Dril Depth NOTE: Depending on bone quality and osteotomy preparation, the insertion torque may vary from 20-70 Ncm. 1.8 x 11.5 mm Initial Drill Parallel Pin/ Depth Gauge 2.2/2.6 x 11.5 mm Twist Step Drill 2.9/3.3 x 11.5 mm Twist Step Drill Prima Plus Implant TM Step 7 Single-Stage Surgery Two-Stage Surgery In a single-stage surgery, the healing abutment is placed with a Quad Driver to help contour the soft tissue during the healing phase. The flap margins are positioned around the Healing Abutment and sutured in a tension-free manner. A radiograph is recommended for use as a baseline of implant-to-bone contact for future diagnosis. In a two-stage surgery, the Cover Screw is placed with a Quad Driver and the flap margins are repositioned and sutured in a tension-free manner. A radiograph is recommended for use as a baseline of implant-to-bone contact for future diagnosis. 15 mm Bone Level 13 mm 11.5 mm 10 mm 8 mm Over Drill Depth 10 11 Twist Step Drills Over Drill Depth Ø3.5 mm 0.88 mm Ø4.1 mm 0.83 mm Ø5.0 mm 1.03 mm Ø6.0 mm 1.13 mm

PRIMA PLUS DRILLING SEQUENCE DRILL SEQUENCE Drill protocols are based on bone quality. Drill dimensions in brackets denote that widening of the crestal bone for insertion torques above 70Ncm is recommended. Implant Ø (mm) Soft Bone Type IV Medium Bone Type II - III Dense Bone Type I SD 3.5 RD 4.1 WD 5.0 WD 6.0 1.8 1.8 1.8 (2.2/2.6) 2.2/2.6 2.2/2.6 (2.6/2.9) 2.6/2.9 (2.9/3.3) 1.8 1.8 1.8 2.2/2.6 2.2/2.6 2.2/2.6 (2.6/2.9) 2.9/3.3 2.9/3.3 (3.4/3.9) 1.8 1.8 1.8 2.2/2.6 2.2/2.6 2.2/2.6 2.9/3.3 2.9/3.3 2.9/3.3 3.4/3.9 3.8/4.1 3.8/4.1 (4.4/4.8) 1.8 1.8 1.8 2.2/2.6 2.2/2.6 2.2/2.6 2.9/3.3 2.9/3.3 2.9/3.3 3.4/3.9 3.4/3.9 3.8/4.1 (4.6/5.3) 4.4/4.8 4.4/4.8 (4.6/5.3) 4.6/5.3 (5.3/5.7) Implant Ø (mm) Soft Bone Type IV Medium Bone Type II - III Dense Bone Type I SD 3.5 1+(2) 1+2+(3) 1+2+3+(4) RD 4.1 1+2+(3) 1+2+4 1+2+4+(5) WD 5.0 1+2+4+5 1+2+4+6 1+2+4+6+(7) WD 6.0 1+2+4+5+(8) 1+2+4+5+7+(8) 1+2+4+6+7+8+(9) 12 13

Smarter Thinking. Simpler Design. Keystone Dental, Inc. Global Headquarters 154 Middlesex Turnpike Burlington, MA 01803 USA General Inquiries: 781-328-3600 Customer Relations: 866-902-9272 or 781-328-3490 Fax: 866-903-9272 or 781-328-3400 Email: info@keystonedental.com Keystone Dental, Inc. 5 Holland, Building 209 Irvine, CA 92618 USA EMERGO Europe B.V. Prinsessgracht 20 2514 AP The Hague The Netherlands 0086 Caution, consult accompanying documents Trademark Acknowledgements Prima Plus TM, Smarter Thinking. Simpler Design. and TiLobe are trademarks and registered trademarks of Keystone Dental, Inc. 2017 Keystone Dental, Inc. 100045-EN01 REV A 11/2017