Dose escalation with external beam therapy for

Similar documents
Department of Radiotherapy & Nuclear Medicine, National Cancer Institute, Cairo University, Cairo, Egypt.

External Beam Radiation Therapy for Low/Intermediate Risk Prostate Cancer

CyberKnife SBRT for Prostate Cancer

Radiation Therapy for Prostate Cancer. Resident Dept of Urology General Surgery Grand Round November 24, 2008

New Technologies for the Radiotherapy of Prostate Cancer

Modern Dose Fractionation and Treatment Techniques for Definitive Prostate RT

PROSTATE CANCER, Radiotherapy ADVANCES in RADIOTHERAPY for PROSTATE CANCER

Subject: Image-Guided Radiation Therapy

An Update on Radiation Therapy for Prostate Cancer

Prostate Cancer. 3DCRT vs IMRT : Hasan Murshed

Future Directions in Prostate Cancer: The Case for Protons. John J. Coen, MD Helen & Harry Gray Cancer Center

High Risk Localized Prostate Cancer Treatment Should Start with RT

Would SBRT Hypofractionated Approach Be as Good? Then Why Bother With Brachytherapy?

Radiation treatment in prostate cancer : balancing between tumor control and toxicity Heemsbergen, W.D.

Clinical Commissioning Policy Proposition: Proton Beam Therapy for Cancer of the Prostate

Outcomes Following Negative Prostate Biopsy for Patients with Persistent Disease after Radiotherapy for Prostate Cancer

Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments

Does RT favor RP in long term Quality of Life? Juanita Crook MD FRCPC Professor of Radiation Oncology University of British Columbia

PROSTATE CANCER TREATMENT

INTRAFRACTION PROSTATE MOTION DURING IMRT FOR PROSTATE CANCER

Research Article Implant R100 Predicts Rectal Bleeding in Prostate Cancer Patients Treated with IG-IMRT to 45 Gy and Pd-103 Implant

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

Intrafractional prostate motion during external beam radiotherapy monitored by a real-time target localization system

Measuring and Predicting Prostate Cancer Related Quality of Life Changes Using EPIC for Clinical Practice

Computed tomography based evaluation of prostatic fiducial marker migration between the periods of insertion and simulation

PACE Study. Hypofractionation 17/12/2014. Traditional Model of Fractionation 200 Response. What s the fraction sensitivity of prostate cancer?

Michael J. Zelefsky MD a,, W. Robert Lee MD b, Anthony Zietman MD c, Najma Khalid MS d, Cheryl Crozier RN d, Jean Owen PhD d, J.

BRACHYTHERAPY FOR PROSTATE CANCER. Dr Brandon Nguyen MBBS(Hons), FRANZCR Radiation Oncologist, The Canberra Hospital

Linac Based SBRT for Low-intermediate Risk Prostate Cancer in 5 Fractions: Preliminary Report of a Phase II Study with FFF Delivery

The Non-Gaussian Nature of Prostate Motion Based on Real-Time Intrafraction Tracking

Radiation with oral hormonal manipulation for non-metastatic, intermediate or high risk prostate cancer in men 70 and older or with comorbidities

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Different approaches are used in the treatment of low-risk

Supported by M. D. Anderson Cancer Center physician investigator funds. We thank Gerald E. Hanks, MD, for help and guidance with this project.

2013 American College of Radiology /13/$36.00

UvA-DARE (Digital Academic Repository) Towards image-guided radiotherapy of prostate cancer Smitsmans, M.H.P. Link to publication

Intensity Modulated Radiotherapy (IMRT) of the Prostate

Prostate Cancer in comparison to Radiotherapy alone:

Prostate Cancer Dashboard

University of California, Los Angeles, Los Angeles, CA, 2 FROS Radiation Oncology and CyberKnife Center, Flushing, NY, 3

PSA bouncing after brachytherapy HDR and external beam radiation therapy: a study of 121 patients with minimum 5-years follow-up

2017 American Medical Association. All rights reserved.

Clinical Policy Bulletin: Intensity Modulated Radiation Therapy

Proton beam therapy for prostate cancer. 1. What is the clinical effectiveness of proton beam therapy in the treatment of prostate cancer?

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Radiation Dose Escalation for Localized Prostate Cancer

New research in prostate brachytherapy

Stereotactic ablative body radiation for prostate cancer SABR

Randomized phase II trial of urethral sparing intensity modulated radiation therapy in low-risk prostate cancer: implications for focal therapy

Radical Prostatectomy versus Intensity Modulated Radiation Therapy in the Management of Localized Prostate Cancer

Dosimetric effects of prone and supine positions on post-implant assessments for prostate brachytherapy

The sigmoid colon and bladder shielding in whole pelvic irradiation at prostate cancer (forward planned IMRT from Institute of Oncology Ljubljana)

Survivorship Beyond Convalescence: 48-Month Quality-of-Life Outcomes After Treatment for Localized Prostate Cancer

2/14/09. Why Discuss this topic? Managing Local Recurrences after Radiation Failure. PROSTATE CANCER Second Treatment

IMRT RTOG Definitive IMRT for Low Risk Prostate Cancer. All about dose and dose matters, probably Although hormones may matter

The Phoenix Definition of Biochemical Failure Predicts for Overall Survival in Patients With Prostate Cancer

Overview of Radiotherapy for Clinically Localized Prostate Cancer

PROSTATE CANCER BRACHYTHERAPY. Kazi S. Manir MD,DNB,PDCR RMO cum Clinical Tutor Department of Radiotherapy R. G. Kar Medical College

Particle (proton) Therapy Randomized trials vs. Prospective registry. Andrew K. Lee, MD, MPH Associate Professor Department of Radiation Oncology

A comparative study of radical prostatectomy and permanent seed brachytherapy for low- and intermediate-risk prostate cancer

Disclosures. Proton therapy advantages. Why are comparing therapies difficult? Proton Therapy for Low Risk Prostate Cancer

HIGH DOSE RADIATION DELIVERED BY INTENSITY MODULATED CONFORMAL RADIOTHERAPY IMPROVES THE OUTCOME OF LOCALIZED PROSTATE CANCER

EORTC radiation Oncology Group Intergroup collaboration with RTOG EORTC 1331-ROG; RTOG 0924

CLINICAL TRIALS Open clinical uro-oncology trials in Canada George Rodrigues, MD, Eric Winquist, MD

INTENSITY MODULATED RADIATION THERAPY: Next Generation 3-D CRT or Distinct Form of RT?

Pancreatic Cancer and Radiation Therapy

Intensity Modulated Radiation Therapy (IMRT)

Innovazioni tecnologiche in Radioterapia" Sergio Fersino Radioterapia Oncologica

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Quality of Life After Modern Treatment Options for Prostate Cancer Ronald Chen, MD, MPH

Evaluation of prognostic factors after radical prostatectomy in pt3b prostate cancer patients in Japanese population

Medical Policy. MP Hydrogel Spacer use During Radiotherapy for Prostate Cancer

Corporate Medical Policy

Acute toxicity profile in prostate cancer with conventional and hypofractionated treatment

MRI Applications in Radiation Oncology:

Prospective assessment of the quality of life before, during and after image guided intensity modulated radiotherapy for prostate cancer

Best Papers. F. Fusco

Introduction. Methods. Original Article: Clinical Investigation

Open clinical uro-oncology trials in Canada

The Use of Conformal Radiotherapy and the Selection of Radiation Dose in T1 or T2 Prostate Cancer

Quality of life after high-dose-rate brachytherapy monotherapy for prostate cancer

Three-year outcomes of 324 prostate carcinoma patients treated with combination high-dose-rate brachytherapy and intensity modulated radiation therapy

Subject Index. Androgen antiandrogen therapy, see Hormone ablation therapy, prostate cancer synthesis and metabolism 49

Jure Murgic 1, Matthew H Stenmark 1, Schuyler Halverson 1, Kevin Blas 1, Felix Y Feng 1,2 and Daniel A Hamstra 1,3*

Real-Time Intra-Fraction Motion Management during Radiation Therapy

Proton Therapy for Prostate Cancer. Andrew K. Lee, MD, MPH Director Proton Therapy Center

10th anniversary of 1st validated CaPspecific

1. CyberKnife Centers of San Diego, CA 2. Coast Urology La Jolla, CA 3. Sletten Cancer Center Great Falls, MT

A PRACTICAL METHOD TO ACHIEVE PROSTATE GLAND IMMOBILIZATION AND TARGET VERIFICATION FOR DAILY TREATMENT

CBCT of the patient in the treatment position has gained wider applications for setup verification during radiotherapy.

The Paul Evans Memorial Lecture Functional radiotherapy targeting using focused dose escalation. Roberto Alonzi Mount Vernon Cancer Centre

Open clinical uro-oncology trials in Canada Eric Winquist, MD, George Rodrigues, MD

Prostate Cancer Treatment for Economically Disadvantaged Men

Neoplasie prostatiche Radioterapia: le nuove strategie

IMAGE GUIDED RADIOTHERAPY BY CBCT BASED POSITION VERIFICATION IN HIGH RISK CARCINOMA PROSTATE- AN INDIAN EXPERIENCE AND REVIEW OF LITERATURE ABSTRACT

INTERNATIONAL JOURNAL OF ONCOLOGY 46: , 2015

Salvage HDR Brachytherapy. Amit Bahl Consultant Clinical Oncologist The Bristol Cancer Institute, UK

UPDATE OF DUTCH MULTICENTER DOSE-ESCALATION TRIAL OF RADIOTHERAPY FOR LOCALIZED PROSTATE CANCER

Transcription:

Rapid Communication Reduction in Patient-reported Acute Morbidity in Prostate Cancer Patients Treated With 81-Gy Intensity-modulated Radiotherapy Using Reduced Planning Target Volume Margins and Electromagnetic Tracking: Assessing the Impact of Margin Reduction Study Howard M. Sandler, Ping-Yu Liu, Rodney L. Dunn, David C. Khan, Scott E. Tropper, Martin G. Sanda, and Constantine A. Mantz OBJECTIVE METHODS RESULTS CONCLUSIONS To investigate whether patient-reported quality of life after high-dose external beam intensitymodulated radiotherapy for prostate cancer can be improved by decreasing planning target volume margins while using real-time tumor tracking. Study patients underwent radiotherapy with nominal 3-mm margins and electromagnetic real-time tracking. Morbidity was assessed before and at the end of radiotherapy using Expanded Prostate Cancer Index Composite (EPIC) questionnaires. Changes in scores were compared between the Assessing Impact of Margin Reduction (AIM) study cohort and the comparator Prostate Cancer Outcomes and Satisfaction with Treatment Quality Assessment (PROST-QA) cohort, treated with conventional margins. The 64 patients in the prospective AIM study had generally less favorable clinical characteristics than the 153 comparator patients. Study patients had similar or slightly poorer pretreatment EPIC scores than comparator patients in bowel, urinary, and sexual domains. AIM patients receiving radiotherapy had less bowel morbidity than the comparator group as measured by changes in mean bowel and/or rectal domain EPIC scores from pretreatment to 2 months after start of treatment ( 1.5 vs 16.0, P.001). Using a change in EPIC score 0.5 baseline standard deviation as the measure of clinical relevance, AIM study patients experienced meaningful decline in only 1 health-related quality of life domain (urinary) whereas decline in 3 health-related quality of life domains (urinary, sexual, and bowel/rectal) was observed in the PROST-QA comparator cohort. Prostate cancer patients treated with reduced margins and tumor tracking had less radiotherapyrelated morbidity than their counterparts treated with conventional margins. Highly contoured intensity-modulated radiotherapy shows promise as a successful strategy for reducing morbidity in prostate cancer treatment. UROLOGY 75: 1004 1008, 2010. 2010 Elsevier Inc. Supported by Calypso Medical Technologies, Inc. and NIH R01CA 95662. P-Y Liu, and R.L. Dunn, are paid statistical consultants for Calypso Medical Technologies, Inc. Presented at the 51st annual meeting of the American Society for Therapeutic Radiology and Oncology (ASTRO), November 1-4, 2009. From the Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California; Fred Hutchinson Cancer Research Center, Seattle, Washington; Department of Urology, University of Michigan, Ann Arbor, Michigan; 21st Century Oncology, Santa Monica, California; 21st Century Oncology, Scottsdale, Arizona; Department of Surgery, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts; and 21st Century Oncology, Cape Coral, Florida Reprint requests: Howard M. Sandler, M.D., M.S., Department of Radiation Oncology, Samuel Oschin Comprehensive Cancer Institute, Cedars-Sinai Medical Center, 8700 Beverly Blvd., Los Angeles, CA 90048. E-mail: howard.sandler@cshs.org Submitted: September 24, 2009, accepted (with revisions): October 25, 2009 Dose escalation with external beam therapy for early-stage prostate cancer results in lower rates of biochemical recurrence, 1-4 although higher doses may increase rates of radiotherapy-related morbidity. 2 Advances in treatment techniques, such as intensitymodulated radiotherapy (IMRT), permit dose escalation while constraining the dose delivered to the rectum and bladder. Rectal dose depends on the margin (ie, radial expansion) added to the clinical target volume (CTV) to create a planning target volume (PTV) that accounts for prostate motion, occurring between (interfraction) and during (intrafraction) daily treatments. Dosimetric modeling studies show that reducing the PTV margin predicts for less rectal toxicity. 5,6 1004 2010ElsevierInc. 0090-4295/10/$34.00 All Rights Reserved doi:10.1016/j.urology.2009.10.072

Strategies to manage target motion include daily inroom computed tomography, prostate ultrasound, gold fiducial imaging, rectal balloons, and electromagnetic tracking. We undertook a clinical study to determine whether reducing PTV margin results in clinical improvements in patient-reported health-related quality of life (HRQOL). 7 Electromagnetic localization has been assessed clinically, 8 but this is the first outcomes-based study evaluating the clinical effect of reduced treatment margins. We compared morbidity between enrolled patients and a similarly assessed, contemporary, well-studied cohort of patients (PROST-QA) who underwent prostate IMRT using conventional PTV margins. 9 MATERIALS AND METHODS Participants Patients with localized prostate cancer were enrolled in an institutional review board approved prospective multi-institutional study (Assessing the Impact of Margin Reduction [AIM]). There were no restrictions on Gleason score, T-stage, pretreatment prostate-specific antigen, or hormonal therapy. Patients underwent intraprostatic implantation of Beacon transponders (Calypso Medical Technologies Inc., Seattle, WA) and were treated with IMRT to a nominal dose of 81 Gy in 1.8-Gy fractions to the prostate and proximal seminal vesicles, using uniform 3-mm PTV margins with 95% PTV coverage by the prescription dose. Radiation Therapy Oncology Group standards were used for structure definition. Treatments were monitored with the Calypso System using a 2-mm intervention threshold. Delivery was paused and/or patients realigned when the threshold was exceeded. AIM patients ( neoadjuvant hormonal therapy, NHT) and non-nht comparator patients 9 completed Expanded Prostate Cancer Index Composite (EPIC) questionnaires before and at 2 months after start of radiation (pretreatment and post-treatment, respectively). The timing of the pretreatment assessment for the NHT comparator group differed, so that group was not used. The post-treatment questionnaire response rate was 89% for AIM and 97% for the comparator. Statistical Analysis The primary endpoint of the AIM study was patient-reported morbidity associated with radiotherapy. Patients completed the full EPIC questionnaire 7 in writing, at home or in the clinic, per Radiation Therapy Oncology Group guidelines. Reported analyses were restricted to the EPIC 26 subset of questions to permit comparison with the comparator study (questionnaires completed by telephone at home). 9,10 Differences between pretreatment and post-treatment EPIC scores were compared between AIM and comparator patients in a patient-level regression analysis, accounting for pretreatment score, age, race, education, body mass index, prostate volume, and cancer risk (based on prostate-specific antigen, Gleason score, and T-stage). P values.05 were considered statistically significant. Reported P values are 2-sided. As described in the comparator study, 9 a clinically relevant change in HRQOL was defined as a difference from pretreatment to post-treatment that exceeded half of the standard deviation of the pretreatment value. 11 We set target enrollment at a minimum of 50 patients. On the basis of prior experience, we assumed the standard deviation for within-patient pretreatment to post-treatment changes in the EPIC bowel domain score to be approximately 20. With 50 AIM patients and 150 non-nht comparator patients, the power to detect a difference of 10 between studies is approximately 0.85 with a 2-sample t test at a 0.05 significance level. RESULTS Patients AIM patients had generally less favorable clinical characteristics than comparator patients (Table 1). Radiotherapy A total of 61 AIM patients were treated supine and 3 prone. The median prescription dose was 81 Gy (79.8 1.7 Gy). Actual PTV margins were 3 mm uniform (52 patients); 3 mm posterior, 4 mm lateral, 5 mm superiorinferior (3 patients); 4 mm uniform (2 patients); 5 mm uniform (2 patients); and 5 mm uniform to 50.4 Gy followed by 3 mm uniform to 81 Gy (5 patients). Median (standard deviation [SD]) values were PTV maximum dose 87 Gy (2 Gy), rectalv70 10% (4%), rectalv50 27% (9%), bladderv70 10% (6%), and bladderv50 20% (13%). For the comparator group, radiotherapy was delivered according to each center s policies, using high doses of radiotherapy (75.6-79.2-Gy prescription doses in 1.8- to 2.0-Gy fractions) and conventional margins (5-10 mm) with 5- to 7-mm rectal margins (Personal communication with radiation oncologists from comparator centers). Patient-Reported Morbidity Table 2 shows the mean EPIC scores for AIM patients ( NHT and non-nht) and the non-nht comparator group. For each domain, the AIM cohort had similar or slightly lower pretreatment scores. The post-treatment change in scores for AIM patients was significantly smaller (indicating better HRQOL) than in the comparator group for the bowel and/or rectal domain. In that domain, the decrease in score was 1.5 in the AIM cohort, compared with 16.0 in the comparator cohort (P.001). The results for the non-nht group were similar to those for the NHT group. The post-treatment change in scores for AIM patients was similar to or better than in the comparator group for the other 3 domains. AIM patients had no clinically relevant treatmentrelated worsening of symptoms in 7 of 8 categories, whereas the comparator group showed clinically relevant declines in 3 of 4 categories (Table 2). Table 3 shows percentages of patients reporting specific bowel and/or rectal symptoms, to provide context for the EPIC scores in terms of patient symptoms. For example, the percentage of patients reporting rectal urgency increased from 3% to 22% in the comparator group but did not increase in the AIM group. Furthermore, the percentage of patients reporting an overall bowel prob- UROLOGY 75 (5), 2010 1005

Table 1. Patient characteristics of the AIM study and comparator study 9 participants Characteristic AIM Study (n 64*) Comparator Study (n 153 ) P Enrollment period September 2008-June 2009 March 2003-March 2006 Age Median (y) 69 69.35 Range (y) 55-86 47-83 Age group, no. (%).08 60 y 3 (5) 22 (14) 60-69 y 35 (55) 66 (43) 70 y 26 (41) 65 (42) Race, no. (%) White 35 (55) 121 (81).001 Black 19 (30) 27 (18) Other 10 (16) 2 (1) Not reported 0 3 College graduate or postgraduate education, 27 (43) 77 (50).37 no. (%) Mean body mass index ( SD) 28.1 4.6 28.5 5.4.75 Mean prostate volume, ml ( SD) 61.0 25.9 50.0 27.0.001 PSA Mean (ng/ml) 8.3 6.2 6.8 4.3 Median (ng/ml) 6.7 5.8.04 Range (ng/ml) 0.6-36.8 0.5-25.8 Group, no. (%).46 4 ng/ml 9 (14) 31 (20) 4-10 ng/ml 41 (64) 96 (63) 10 ng/ml 14 (22) 26 (17) Gleason score on biopsy, no. (%) 7 32 (50) 97 (63).001 7 26 (41) 56 (37) 7 6 (9) 0 (0) Clinical stage, no. (%) T1 32 (50) 123 (80).001 T2 31 (48) 30 (20) T3 1 (2) 0 (0) Overall cancer severity**, no. (%) Low-risk 15 (23) 61 (40).003 Intermediate-risk 41 (64) 88 (58) High-risk 8 (13) 4 (3) AIM, Assessing the impact of margin reduction; PSA, prostate-specific antigen. * Seventy-seven patients were enrolled and underwent transponder implantation before IMRT. Thirteen were excluded from analyses, 8 did not complete a post-treatment questionnaire, 1 had a questionnaire that was lost in the mail, 2 withdrew for personal reasons, and 2 received whole pelvic radiation. Analyses were based on 64 patients (43 treated without NHT). The comparator study included 292 patients treated with IMRT or highly conformal external beam therapy; 153 were treated with IMRT without NHT and formed the comparator group. None received electromagnetic localization. Wilcoxon s test. 2 test. Categories of race collected in the AIM study were White/Caucasian (not Latino/Hispanic), Black/African American (not Latino/ Hispanic), Latino/Hispanic/Mexican-American, Asian/Oriental/Pacific Islander, Native American/Native Alaskan, and other. Categories reported in the comparator study were White, Black, and other. Patients reporting race as Latino, Asian, Native American, and other in the AIM study were combined as other to permit comparison. Fisher exact test (AIM, n 63 for College or higher education; comparison was T1 vs T2/3 for Clinical Stage). ** Cancer severity was determined based on the following definition given in the comparator study: low-risk (PSA 10, Gleason score 7, and T1), high-risk (Gleason score 7 orpsa 20), and intermediate-risk (all patients who are not at low- or high-risk). lem increased from 4% to 20% in the comparator group but did not increase in the AIM group. COMMENT This is the first prospective prostate cancer radiotherapy study to report outcomes using reduced PTV margins enabled by real-time tracking. This allowed for continuous management of intrafraction prostate motion, which may be critical when using small margins. 12 This study was not randomized and used a recent, albeit historical, comparator. Variations in unmeasured characteristics could have influenced the findings. Comparator patients completed questionnaires through telephone, whereas some AIM patients completed questionnaires in the clinic. This could lead to a more favorable outcome for the latter, since patients may be less likely to report their outcome negatively if treating personnel are nearby. A prospective, concurrent trial comparing reduced margins with standard IMRT, using identical administration of EPIC, would address this limitation. Nonetheless, our comparison is strengthened by several factors. AIM patients had generally less favorable 1006 UROLOGY 75 (5), 2010

Table 2. Comparison of patient-reported morbidity between patients in the AIM study (n 64 for all patients and n 43 for patients treated only with radiotherapy) and patients in the comparator study 9 treated only with radiotherapy (n 153) EPIC Domain and Study (n) EPIC Score, Mean (SD)* Pretreatment Post-treatment (2 mon) Mean Difference Clinically Meaningful (95% CI) P Decline ( 0.5 SD) Bowel/rectal AIM NHT (63) 90.3 (19.3) 88.8 (17.3) 1.5 ( 7.6, 4.5).001 No AIM non-nht (41) 91.8 (19.2) 89.8 (17.6) 1.9 ( 9.0, 5.1).001 No Comparator (148) 94.4 (10.8) 78.5 (20.9) 16.0 ( 19.4, 12.5) Yes Urinary irritation/obstruction AIM NHT (58) 85.8 (17.3) 79.0 (24.2) 6.8 ( 12.2, 1.3).07 No AIM non-nht (38) 84.5 (18.0) 80.6 (23.0) 4.0 ( 10.0, 2.1).03 No Comparator (148) 86.6 (14.3) 70.1 (20.7) 16.5 ( 19.8, 13.3) Yes Urinary incontinence AIM NHT (61) 89.4 (14.7) 84.4 (21.8) 5.0 ( 9.5, 0.5).72 No AIM non-nht (43) 93.0 (12.5) 86.3 (21.0) 6.7 ( 12.1, 1.3).90 Yes Comparator (138) 92.5 (13.1) 84.6 (20.5) 7.9 ( 11.0, 4.8) Yes Sexual AIM NHT (62) 46.2 (33.5) 43.8 (30.3) 2.4 ( 9.6, 4.9).17 No AIM non-nht (43) 50.9 (32.1) 50.9 (26.9) 0.0 ( 8.6, 8.6).04 No Comparator (133) 63.5 (27.8) 51.5 (30.0) 12.0 ( 15.4, 8.5) No EPIC, Expanded Prostate Cancer Index Composite; CI, confidence interval; AIM, Assessing the Impact of Margin Reduction; NHT, neoadjuvant hormonal therapy. * Scores for each domain range from 0 to 100. Higher scores indicate better health-related quality of life. Calculated from within-patient differences. Regression P value comparing the pretreatment to post-treatment difference for AIM vs comparator, taking into account pretreatment EPIC score, age, race, college graduate or postgraduate education, body mass index, prostate volume, and cancer risk. Table 3. Rates of specific bowel and/or rectal clinical symptoms EPIC Item for Bowel Function AIM Study (n 64) Comparator Study 9 (n 153) Patient % Patient % Pretreatment Post-treatment (2 mo) Pretreatment Post-treatment (2 mo) Urgency 9 8 3 22 Frequency 3 8 2 22 Fecal incontinence 3 3 1 7 Bloody stools 3 2 2 5 Rectal pain 6 3 5 9 Overall bowel problem 9 6 4 20 EPIC, Expanded Prostate Cancer Index Composite; AIM, Assessing the Impact of Margin Reduction. clinical and tumor characteristics than comparator patients. Baseline factors known to predict treatment morbidity were taken into account. The radiation dose delivered to AIM patients was the same as or higher than that for comparator patients. Comparator patients were treated at centers of excellence using state-of-the-art IMRT techniques of those institutions and margin definitions that remain widely in use. The outcome metrics represent validated patient assessment tools rather than physician interpretation of complications. Minimizing dose to normal tissues is a central tenet of radiotherapy. Modeling studies estimate that reducing the PTV margin in prostate cancer radiotherapy from 7 to 3 mm should decrease rectal toxicity by 12%. 6 Our findings support these observations and are consistent with results from a randomized trial, wherein fewer late rectal toxicities were observed with more contoured plans. 13 Patients treated with reduced margins and a nominally higher prescription dose experienced fewer acute adverse HRQOL effects. Given the nature of the comparison, a detailed assessment of normal tissue dose exposure and PTV dose delivery was not done. Therefore, one must be cautious about the robustness of the dose comparison. Nevertheless, given the prescription dose of 81 Gy and the median maximum PTV dose of 87 Gy, it seems unlikely that AIM patients had PTV undertreatment vs comparator patients. As expected, this benefit is greatest for rectal adverse effects, where narrower margins directly reduce the volume of irradiated rectum. Improvement is somewhat less in the urinary irritation or obstruction domain, which reflects the combined effects of bladder irritability and prostatic obstruction. Bladder irritability may be reduced by margin reduction, but prostatic obstructive symptoms are unlikely to be affected as the entire prostate necessarily remains in-field. Urinary incontinence shows little difference as this is a late treatment effect. Sexual function scores for AIM patients show little or no post-treatment decline, in contrast to comparator patients. Sexual interest may UROLOGY 75 (5), 2010 1007

be better maintained in the absence of bowel and urinary toxicity. Acute normal tissue damage due to prostate radiotherapy has been shown to predict clinically significant late damage. 14,15 These experiences suggest that the reduction in acute morbidity observed in the AIM study may translate to a reduction in long-term morbidity with longer follow-up. In conclusion, reducing the PTV margin is an attractive option when prostate motion can be carefully managed during daily radiation treatment, as this reduction can result in decreased acute treatment-related adverse effects. Margin reduction is a logical step in the evolution of IMRT and may support radiotherapy strategies that contribute to better long-term outcomes. Acknowledgments. We gratefully acknowledge the contributions of Jeff M. Michalski, Arul Mahadevan, Deborah A. Kuban, Irving Kaplan, and Jay P. Ciezki, whose patients comprised the comparator group for this study and whose data were essential for carrying out this analysis. We are also grateful to John T. Wei for helpful conversations regarding the EPIC questionnaire. References 1. Zietman AL, DeSilvio ML, Slater JD, et al. Comparison of conventional-dose vs. high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate. JAMA. 2005;294: 1233-1239. 2. Kuban DA, Tucker SL, Dong L, et al. Long-term results of the M. D. Anderson randomized dose-escalation trial for prostate cancer. Int J Radiat Oncol Biol Phys. 2008;70:67-74. 3. Peeters ST, Heemsbergan WD, Koper PC, et al. Dose response in radiotherapy for localized prostate cancer: results of the Dutch multicenter randomized phase III trial comparing 68 Gy of radiotherapy with 78 Gy. J Clin Oncol. 2006;24:1990-1996. 4. Dearnaley DP, Sydes MR, Graham JD, et al. Escalated-dose versus standard-dose conformal radiotherapy in prostate cancer: first results from the MRC RT01 randomized controlled trial. Lancet Oncol. 2007;8:475-487. 5. Gauthier I, Carrier JF, Béliveau-Nadeau D, et al. Dosimetric impact and theoretical clinical benefits of fiducial markers for dose escalated prostate cancer radiation treatment. Int J Radiat Oncol Biol Phys. 2009;74:1128-1133. 6. Huang SH, Catton C, Jezioranski J, et al. The effect of changing technique, dose, and PTV margin on therapeutic ratio during prostate radiotherapy. Int J Radiat Oncol Biol Phys. 2008;71:1057-1064. 7. Wei JT, Dunn RL, Litwin MS, et al. Development and validation of the expanded prostate cancer index composite (EPIC) for comprehensive assessment of health-related quality of life in men with prostate cancer. Urology. 2000;56:899-905. 8. Kupelian P, Willoughby T, Mahadevan A, et al. Multi-institutional clinical experience with the Calypso system in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy. Int J Radiat Oncol Biol Phys. 2007;67:1088-1098. 9. Sanda MG, Dunn RL, Michalski J, et al. Quality of life and satisfaction with outcome among prostate-cancer survivors. N Engl J Med. 2008;358:1250-1261. 10. Scoring instructions for the expanded prostate cancer index composite (EPIC): University of Michigan. Available at: http:// roadrunner.cancer.med.umich.edu/epic/epic-scoring-2.2002.pdf. Accessed August 12, 2009. 11. Norman GR, Sloan JA, Wyrwich KW. Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation. Med Care. 2003;41:582-592. 12. Litzenberg DW, Balter JM, Hadley SW, et al. Influence of intrafraction motion on margins for prostate radiotherapy. Int J Radiat Oncol Biol Phys. 2006;65:548-553. 13. Dearnaley DP, Khoo VS, Norman AR, et al. Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trial. Lancet. 1999;353:267-272. 14. Heemsbergen WD, Peeters ST, Koper PC, et al. Acute and late gastrointestinal toxicity after radiotherapy in prostate cancer patients: consequential late damage. Int J Radiat Oncol Biol Phys. 2006;66:3-10. 15. Zelefsky MJ, Levin EJ, Hunt M, et al. Incidence of late rectal and urinary toxicities after three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for localized prostate cancer. Int J Radiat Oncol Biol Phys. 2008;70:1124-1129. 1008 UROLOGY 75 (5), 2010