Endoleak Visualized With Carbon Dioxide Angiography During Endovascular Aneurysm Repair Using the Endurant Stent-Graft

Similar documents
Nellix Endovascular System: Clinical Outcomes and Device Overview

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Abdominal and thoracic aneurysm repair

Management of Endoleaks

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Abdominal Aortic Aneurysm (AAA)

Intravascular Ultrasound in the Treatment of Complex Aortic Pathologies. Naixin Kang, M.D. Vascular Surgery Fellow April 26 th, 2018

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

Alma Mater Studiorum Bologna University. S.Orsola-Malpighi, Bologna, Italy Vascular Surgery. CO 2 angiography for. EVAR procedure. E.

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Endovascular aortic aneurysm repair with carbon dioxide-guided angiography in patients with renal insufficiency

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Management of Endoleaks. Michael Meuse, M.D Vascular and Interventional Radiology 12/14/09

LOWERING THE PROFILE RAISING THE BAR

From 1996 to 1999, a total of 1,193 patients with

The diagnostic and treatment challenge of type IIIb endoleaks

Technique and Tips for Complicated AAA Cases with Stent Graft

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Talent Abdominal Stent Graft

Management of Endoleaks

Hostile Proximal Neck: A New Conformable EVAR Device

Considerations for a Durable Repair

An endoleak is radiographic or ultrasonic evidence

TriVascular Ovation Prime Abdominal Stent Graft System

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

Percutaneous Approaches to Aortic Disease in 2018

Access More Patients. Customize Each Seal.

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Aortic stents, types, selection, tricks in deployment.

Description. Section: Surgery Effective Date: April 15, Subsection: Surgery Original Policy Date: December 6, 2012 Subject:

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

Type-II Endoleaks Following Endovascular AAA Repair: Preoperative Predictors and Long-term Effects

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Reimbursement Guide Zenith Fenestrated AAA Endovascular Graft

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Residual Dissection and False Lumen Aneurysm After TEVAR

Improving Endograft Durability with EndoAnchors

A New EVAR Device for Infrarenal AAAs

Abdominal Aortic Aneurysm 가천대길병원 이상준

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type 1b Endoleak following an EVAR for Ruptured AAA

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Experience of endovascular procedures on abdominal and thoracic aorta in CA region

Treatment options for endoleaks: stents, embolizations and conversions

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Right Choice for Right Angles

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

My personal experience with INCRAFT in standard and challenging cases

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Endovascular options of treating iliac aneurysms

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

Ultrasound Evaluation after EVAR: (Trying to) Let the CAT Scan Out of the Bag

Educational Exhibit Authors:

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

Type IIIb Endoleak Is an Important Cause of Failure Following Endovascular Aneurysm Repair

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

Case Report Late Type 3b Endoleak with an Endurant Endograft

Anatomical challenges in EVAR

Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN

Ancillary Components with Z-Trak Introduction System

BC Vascular Day. Contents. November 3, Abdominal Aortic Aneurysm 2 3. Peripheral Arterial Disease 4 6. Deep Venous Thrombosis 7 8

NEW INNOVATIONS IN ENDOLEAK MANAGEMENT

Acute dissections of the descending thoracic aorta (Debakey

3. Endoluminal Treatment of Infrarenal Abdominal Aortic Aneurysm

EVAR replaced standard repair in most cases. Why?

Challenging anatomies demand versatility.

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

P Paraplegia abdominal aortic aneurysm repair, 52 paraparesis, 52 pathophysiology, 51 rates and endografts, 51 two-stage approach, 129

Emergency Endovascular Treatment for Ruptured Type B Dissection in the Abdominal Aorta

Free Esophageal Perforation Following Hybrid Visceral Debranching and Distal Endograft Extension to Repair a Ruptured Thoracoabdominal Aortic

Patient selection in Hostile Necks and how. to prevent endoleaks a word of caution

Il trattamento endovascolare dell aorta sottorenale (EVAR) mediante anidride carbonica (AI-CO 2 )

Safety of coil embolization of the internal iliac artery in endovascular grafting of abdominal aortic aneurysms

Volume 3 (2017) Issue 1 ISSN Abstract. Keywords fenestrated after open repair; Pararenal abdominal aortic aneurysm.

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

Hostile Neck During EVAR, The Role Of Endoanchores

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU)

Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair

Tips for Delayed Open Conversion in Patients with a Type III Endoleak after Endovascular Aortic Aneurysm Repair

FROM THE EVERYDAY TO THE EXTRAORDINARY

Eccentric stent graft compression: An indicator of insecure proximal fixation of aortic stent graft

INCRAFT system: Update from the Pivotal INSPIRATION Study

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany

Ruptured Abdominal Aortic Aneurysm: Endovascular Repair is Feasible in 40% of Patients

Endoleak Sealing after AAA Endovascular Repair. When and How?

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study,

AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA. 2 nd -3 rd June 2016.

Endologix PowerWeb System EPW?

Transcription:

172 J ENDOVASC THER 2014;21:172 176 CASE REPORT Endoleak Visualized With Carbon Dioxide Angiography During Endovascular Aneurysm Repair Using the Endurant Stent-Graft Robert P. Garvin, MD; Evan J. Ryer, MD; J. Brian Kendrick, MD; and David P. Franklin, MD Geisinger Medical Center, Danville, Pennsylvania, USA. Purpose: To make interventionists aware of the potential for type IV endoleak on completion carbon dioxide (CO 2 ) angiography during endovascular aneurysm repair (EVAR) using the Endurant stent-graft. Case Report: A 74-year-old man with chronic kidney disease underwent EVAR with an Endurant stent-graft using CO 2 angiography to guide graft placement. Completion CO 2 angiography demonstrated immediate accumulation of CO 2 in the aneurysm sac suggestive of an endoleak, but confirmatory angiography with conventional iodinated contrast showed no evidence of an endoleak. We speculate that this is a type IV endoleak, and graft porosity may be responsible. Conclusion: Interventionists should be alerted to the possibility of visualizing these endoleaks through Endurant stent-grafts under CO 2 angiography. Further work should be done to elucidate the exact mechanism of the endoleak. J Endovasc Ther. 2014;21:172 176 Key words: endovascular aneurysm repair, stent-graft, endoleak, type IV endoleak, CO 2 angiography One of the recognized complications following endovascular aneurysm repair (EVAR) is progressive deterioration of renal function over time. 1,2 Patients with pre-existing renal impairment who undergo EVAR are at increased risk for developing postoperative deterioration of renal function and death. 3,4 There are several causes of renal dysfunction following EVAR, including atheroembolism, contrast-induced nephrotoxicity (CIN), suprarenal fixation, and graft malpositioning. 2 One strategy to mitigate the risk of CIN following EVAR is to use non-iodinated contrast material such as carbon dioxide (CO 2 ). Several authors have reported their experience with CO 2 during EVAR and have shown it to be safe and effective. 5 8 Interestingly, all of these authors reported endoleaks demonstrated during completion CO 2 angiography in their series, with two reports suggesting that CO 2 angiography is more sensitive than conventional angiography for the detection of endoleaks. 5,6 We report a case of an endoleak seen on completion CO 2 angiography during implantation of an Endurant stent-graft, and we postulate a mechanism for this endoleak that requires further study. CASE REPORT A 74-year-old man with stage IV chronic kidney disease presented with acute on Evan J. Ryer is a paid consultant to Cook Medical. The other authors declare no association with any individual, company, or organization having a vested interest in the subject matter/products mentioned in this article. Corresponding author: Robert P. Garvin, MD, Geisinger Medical Center, Department of Vascular and Endovascular Surgery, 100 North Academy Avenue, Danville,PA17822,USA.E-mail:rgarvinmd@yahoo.com; rpgarvin@geisinger. edu Q 2014 by the INTERNATIONAL SOCIETY OF ENDOVASCULAR SPECIALISTS Available at www.jevt.org

J ENDOVASC THER ENDOLEAK AND CO2 ANGIOGRAPHY 173 2014;21:172 176 Garvin et al. chronic renal failure [serum creatinine (SCr) 4.6 md/dl and estimated glomerular filtration rate (egfr) of 12.6 ml/min/1.73 m 2 ] characterized by decompensated congestive heart failure and dyspnea with oliguria. Non-contrast computed tomography (CT) of the abdomen and pelvis demonstrated an incidental asymptomatic 7.9-cm infrarenal abdominal aortic aneurysm (AAA). The patient was a candidate for EVAR, but the procedure was delayed for preoperative hemodialysis to optimize the volume and electrolyte status. The EVAR procedure was performed using intravascular ultrasound (IVUS) and CO 2 angiography to avoid nephrotoxic iodinated contrast. The right kidney was atrophic on the preoperative CT scan, so attention was given to preserving the left renal artery, which was marked with IVUS, along with the bilateral hypogastric arteries. The anatomy was confirmed using CO 2 angiography with planned selective catheterization of the left renal artery prior to graft deployment (Fig. 1A). With the patient under systemic anticoagulation with weight based heparin dosing (100 U/kg) to achieve an activated clotting time of.250 seconds, a bifurcated Endurant stentgraft (Medtronic CardioVascular, Santa Rosa, CA, USA) was successfully implanted through percutaneous access in both common femoral arteries, using CO 2 throughout the case to guide graft placement. Completion CO 2 angiography with 50 ml of compressed gas was performed after treating the seal zones and overlap zones with a Coda balloon in standard fashion. Immediately after CO 2 injection, the aneurysm sac was promptly seen to fill with CO 2 and continued to fill more intensely as the digital subtraction images were acquired (Fig. 1B,C). This immediate visualization of CO 2 in the aneurysm sac was uncharacteristic of a type II endoleak, and given the long 3-cm proximal neck and the favorable iliac landing zones, a type I endoleak on either end seemed rather unlikely. However, feeling compelled to rule out a type I or III endoleak in this patient with a large aneurysm, the decision was made, despite the renal failure, to perform a completion angiogram with iodinated contrast. While still under anticoagulation and without any repeat balloon dilation of the overlap zones, 20 ml of half strength Visipaque (320 mg I/mL, GE Healthcare Canada Inc, Mississauga, ON, Canada) was injected for the final angiogram, which demonstrated no evidence of an endoleak (Fig. 1D). Review of the timing of the images acquired during the procedure revealed that only 3 minutes had elapsed between the CO 2 angiogram and the conventional angiogram. With no endoleak noted on the conventional angiogram, the heparin was reversed, and the femoral access sites were closed. The patient had an uneventful postoperative course and was discharged to home on postoperative day 1 with plans to continue outpatient hemodialysis with regular monitoring of his renal function. At the 1-month followup appointment, the patient was recovering well from the aneurysm repair but had demonstrated no signs of renal recovery and was still requiring regular hemodialysis. Non-contrast CT demonstrated a stable position of the bifurcated stent-graft with a small residual pocket of trapped gas anteriorly inside the thrombus of the sac (Fig. 2A). Aortic duplex demonstrated patent graft limbs and no evidence of an endoleak at that time (Fig. 2B). At 13 months, a contrast-enhanced CT angiogram demonstrated stable position of the endograft, resolution of the gas pocket in the sac, no evidence of endoleak, and a decrease in sac size from 7.9 to 6.2 cm (Fig. 2C). DISCUSSION In 1982, Hawkins 9 first described the use of CO 2 as an alternative to iodinated contrast material in a series of 17 patients undergoing diagnostic arteriography. Since then, CO 2 has become well established not only in diagnostic angiography but also in therapeutic techniques. 10 Because of the risk of renal dysfunction associated with EVAR, several authors have used CO 2 during these procedures and have shown it to be safe and effective, 5 8 even for cases of ruptured AAA. 11 As endovascular specialists continue to implement efforts to reduce nephrotoxicity in their patients, CO 2 angiography may play a larger role in the management of patients with chronic kidney disease in the future. The recognized benefits of CO 2 as a contrast material include its ease of use, low cost, lack

174 ENDOLEAK AND CO2 ANGIOGRAPHY J ENDOVASC THER Garvin et al. 2014;21:172 176 Figure 1 (A) Initial CO 2 angiogram via a selective catheter in the left renal artery to mark the position of the artery prior to graft deployment. Note the preferential filling of non-dependent celiac and superior mesenteric arteries. Completion CO 2 angiograms demonstrating (B) early accumulation of CO 2 in the aneurysm sac (white arrows) immediately after injection and (C) progressive accumulation of gas in the sac (white arrows), which persisted after the remainder of the CO 2 washed out. (D) Final completion angiogram using iodinated contrast demonstrating no evidence of an endoleak. The left renal artery and both hypogastric arteries are patent. The right renal artery is chronically occluded. of renal toxicity and allergic reaction, low viscosity facilitating injection through smaller caliber catheters, and overall safety when introduced into the arterial system below the diaphragm. The use of CO 2 is not recommended above the diaphragm where it could theoretically disrupt the blood-brain barrier. Also, any gas introduced into the arterial system can theoretically create a vapor lock in small vessels, causing end organ ischemia, which in the cerebral circulation could lead to anoxic injury. The compressible gas is rapidly dissolved inside the arterial system and eliminated in the lungs during normal respiration. Because the gas is far more buoyant than blood, it rapidly displaces flowing blood within the vascular tree, tending to preferentially fill vessels that are situated in a non-dependent position, such as the celiac artery and superior mesenteric artery (SMA) in a supine patient (Fig. 1A). Some patients report the feeling of nausea immediately after injection in the abdominal aorta. Caution should be

J ENDOVASC THER ENDOLEAK AND CO2 ANGIOGRAPHY 175 2014;21:172 176 Garvin et al. Figure 2 (A) Non-contrast CT scan 1 month after surgery demonstrating a small residual collection of trapped gas anteriorly within the thrombus of the sac (arrow). (B) Duplex scan at 1 month after surgery demonstrating a patent aortic stent-graft without flow in the sac. (C) Contrast-enhanced CT scan at 13 months demonstrating patent graft limbs, no evidence of endoleak, resolution of the anterior gas pocket, and a significant decrease in sac size (arrow). used when attempting to visualize arteries in a dependent position (such as the renal arteries and lumbar arteries) because the CO 2 may not fill these vessels well. The previous reports of CO 2 angiography during EVAR all describe endoleaks in some of the patients following final graft deployment. 5 8 Two of the reports described exclusive use of the Cook Zenith device, 6,7 while the other studies employed multiple devices 5,8 (Guidant Ancure, Gore Excluder, Medtronic AneuRx, and Lombard Aorfix) without reporting the incidence of endoleak based on device type. None of these reports described experience with the Endurant stent-graft, which was used in our patient. Due to the low viscosity of CO 2, it could be postulated that the gas would track more easily between the graft material and the aortic wall (type I endoleak) or between graft components (type III endoleak). Indeed, Chao et al. 5 observed that the CO 2 seems to be more sensitive in detecting endoleaks, but they do not offer a hypothesis as to the exact mechanism to explain the phenomenon. Close scrutiny of the serial acquisition images from the digital subtraction CO 2 angiogram in our patient makes it seem as though the CO 2 passed through the graft fabric almost immediately after injection, causing a type IV endoleak that would not otherwise be detected with conventional angiography. This may be due to the lowviscosity CO 2 being able to permeate the graft fabric. It is unlikely that a type II endoleak would show up with CO 2 angiography because the CO 2 would preferentially fill nondependent arterial branches and not the dependently situated lumbar arteries, unless the CO 2 rapidly coursed through the SMA branches and filled the inferior mesenteric artery retrograde into the sac, which was not visualized on the angiogram. In our patient, the long proximal and distal landing zones would make a type I endoleak less likely, though not impossible. Because only 3 minutes had transpired between the final CO 2 angiogram and the confirmatory conventional angiogram, it is unlikely that the CO 2 angiogram was demonstrating a type I or III endoleak that spontaneously sealed within the intervening 3-minute time frame, thus a type IV endoleak directly through the graft material seemed most plausible. Lastly, the possibility of a type V endoleak needs to be considered, but type V endoleaks usually present in delayed fashion with an increase in sac size over time without another documented type of endoleak. We would not expect a type V endoleak to manifest intraoperatively; furthermore, the 13-month CT scan showed an appreciable decrease in sac size that would rule this out in our patient. The graft material on the Endurant device is a high density woven polyester fabric made from a multifilament yarn. The same multifilament yarn is also used to secure the graft fabric to the stent components without the use of additional suture material. The porosity of this fabric is reported to be

176 ENDOLEAK AND CO2 ANGIOGRAPHY J ENDOVASC THER Garvin et al. 2014;21:172 176 roughly 150 ml/cm 2 /min (direct correspondence with manufacturer). Whether or not this level of porosity would allow direct permeation by CO 2 is unknown, as no benchtop data are available regarding porosity testing using CO 2 with this device (direct correspondence with manufacturer). Since there was no endoleak of any type seen on the conventional angiogram only 3 minutes after the CO 2 angiogram, the final explanation for the CO 2 endoleak remains unresolved. We postulate that graft porosity coupled with the unique physical properties of CO 2 described above may account for this apparently unique type IV endoleak that is seen only with the low-viscosity CO 2.Obviously, this hypothesis needs further study to determine its merit. Conclusion To our knowledge, there are no prior reports of an endoleak using CO 2 during EVAR with the Endurant stent-graft. We are hopeful that further work can be done in this area to elucidate the exact mechanism of the endoleak. Investigating this endoleak caused us to use a small volume of iodinated contrast to confirm the findings, which could only have had a detrimental effect on the patient s renal recovery. Our hope is that as CO 2 use becomes more widely employed in EVAR, we can learn how to interpret CO 2 -related endoleaks and make appropriate clinical decisions that avoid potentially harmful nephrotoxic contrast agents in patients with preexisting renal dysfunction. REFERENCES 1. Greenberg RK, Chuter TA, Lawrence-Brown M, et al. Analysis of renal function after aneurysm repair with a device using suprarenal fixation (Zenith AAA Endovascular Graft) in contrast to open surgical repair. J Vasc Surg. 2004;39: 1219 1228. 2. Walsh SR, Tang TY, Boyle JR, et al. Renal consequences of endovascular abdominal aortic aneurysm repair. J Endovasc Ther. 2008;15: 73 82. 3. Walker SR, Yusuf SW, Wenham PW, et al. Renal complications following endovascular repair of abdominal aortic aneurysms. J Endovasc Surg. 1998;5:318 322. 4. Markovic JN, Rajgor DD, Shortell CK. The impact of diabetes mellitus and renal insufficiency on the outcome of endovascular abdominal aortic aneurysm repair. Perspect Vasc Surg Endovasc Ther. 2010;22:235 244. 5. Chao A, Major K, Kumar SR, et al. Carbon dioxide digital subtraction angiography-assisted endovascular aortic aneurysm repair in the azotemic patient. JVascSurg. 2007;45:451 460. 6. Criado E, Kabbani L, Cho K. Catheter-less angiography for endovascular aortic aneurysm repair: a new application of carbon dioxide as a contrast agent. J Vasc Surg. 2008;48:527 534. 7. Lee AD, Hall RG. An evaluation of the use of carbon dioxide angiography in endovascular aortic aneurysm repair. Vasc Endovasc Surg. 2010;44:341 344. 8. Criado E, Upchurch GR, Young K, et al. Endovascular aortic aneurysm repair with carbon dioxide-guided angiography in patients with renal insufficiency. J Vasc Surg. 2012;55: 1570 1575. 9. Hawkins IF. Carbon dioxide digital subtraction arteriography. AJR Am J Roentgenol. 1982;139: 19 24. 10. Shaw DR, Kessel DO. The current status of the use of carbon dioxide in diagnostic and interventional angiographic procedures. Cardiovasc Interv Radiol. 2006;29:323 331. 11. Knipp BS, Escobar GA, English S, et al. Endovascular repair of ruptured aortic aneurysms using carbon dioxide contrast angiography. Ann Vasc Surg. 2010;24:845 850.