5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany

Similar documents
Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

CVD Diamond X-ray Detectors for Radiotherapy Dosimetry

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

IMRT point dose measurements with a diamond detector

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

MEASUREMENT OF TMR AND PDD PROFILES IN SMALL FIELDS. SB Crowe, E Whittle, C Jones, T Kairn

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

DOSE MEASUREMENTS IN TELETHERAPY USING THERMOLUMINESCENT DOSIMETERS

Application(s) of Alanine

Online Care, Online Control, Online Confidence

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

Small field diode dosimetry

Comparison of microlion liquid filled ionisation chamber with Semiflex and Pinpoint air filled chambers

Medical- and Radiation Physics Research at Surrey

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

MAESTRO: Methods and Advanced Equipment for Simulation and Treatment in Radiation Oncology

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Dosimetric Characteristics of Standard and Micro MOSFET Dosimeters as In-vivo Dosimeter for Clinical Electron Beam

Diode calibration for dose determination in total body irradiation

Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose

COMPARISON OF RADIOBIOLOGICAL EFFECTS OF CARBON IONS TO PROTONS ON A RESISTANT HUMAN MELANOMA CELL LINE

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Ion recombination corrections of ionization chambers in flattening filter-free photon radiation

Dose Homogeneity of the Total Body Irradiation in vivo and in vitro confirmed with Thermoluminescent Dosimeter

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

LONG TERM STABILITY OF THE PERFORMANCE OF A CLINICAL LINEAR ACCELERATOR AND Z-SCORE ASSESSEMENT FOR ABSORBED DOSE TO WATER QUANTITY

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

Plastic scintillation detectors for dose monitoring in digital breast tomosynthesis

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 4, NUMBER 4, FALL 2003

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Neutron dose evaluation in radiotherapy

Neutron Measurements for Intensity Modulated Radiation Therapy

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Online in vivo dosimetry in conformal radiotherapies with MOSkin detectors

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

Imaging of Radiation Dose Using Cherenkov Light

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Volumetric Modulated Arc Therapy - Patient Specific QA

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

Small Field Dosimetry: Overview of AAPM TG-155 and the IAEA-AAPM Code of Practice (Therapy)

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

Basic dosimetric data for treatment planning system

The clinical use of OSLD

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

PMP. Use of Cylindrical Chambers as Substitutes for Parallel- Plate Chambers in Low-Energy Electron Dosimetry. Original Article.

Specific Aspects of Radiochromic Film Dosimetry AAPM Task Group 235 An Update to Task Group 55 (1998)

Stefan Gutiérrez Lores 1, Gonzalo Walwyn Salas 1, Daniel Molina Pérez 1, Raudel Campa Menéndez 2.

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

PROCEDURE FOR ABSORBED DOSE TO WATER DETERMINATION IN HIGH ENERGY PHOTON AND ELECTRON BEAMS BY FERROUS SULPHATE DOSIMETER AT INMRI-ENEA

Limits of Precision and Accuracy of Radiation Delivery Systems

The ANDANTE project: a multidisciplinary approach to neutron RBE

MEASUREMENT OF THE EQUIVALENT INDIVIDUAL DOSES FOR PATIENTS IN ANGIOGRAPHY PROCEDURE AND INTERVENTIONAL RADIOLOGY WITH THERMOLUMINESCENT SYSTEMS

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

Diode Dosimetric Characteristics Assessment for In-Vivo Dosimetry in Radiotherapy Treatment

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

Computed tomography Acceptance testing and dose measurements

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

TOTAL IONIZING DOSE RADIATION TEST REPORT RH3080

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Reference Photon Dosimetry Data for the Siemens Primus Linear Accelerator: Preliminary Results for Depth Dose and Output Factor

FETUS ABSORBED DOSE EVALUATION IN HEAD AND NECK RADIOTHERAPY PROCEDURES OF PREGNANT PATIENTS

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Small Field Dosimetry: Overview of AAPM TG-155 and the IAEA-AAPM Code of Practice (Therapy) What is a Small Field? Indra J. Das/ Small Fields (Page-1)

IORT with mobile linacs: the Italian experience

Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators

Out-of-field dosimetry in radiotherapy for input to epidemiological studies. Roger Harrison

Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams

Calibration of two 90 Sr+ 90 Y dermatological applicators

Neutrons. ρ σ. where. Neutrons act like photons in the sense that they are attenuated as. Unlike photons, neutrons interact via the strong interaction

Slide 1. Slide 2. Slide 3. Introduction of INTRABEAM IORT. Disclosure. Contents. I have nothing to disclose.

3-D dose verification by cone-beam optical CT scanning of PRESAGE dosimeter

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

IAEA-CN THE ESTRO-EQUAL RESULTS FOR PHOTON AND ELECTRON BEAMS CHECKS IN EUROPEAN RADIOTHERAPY BEAMS*

Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber



Radiochromic film dosimetry in water phantoms

Response evaluation of CaSO4:Dy; LiF:Mg,Ti and LiF:Mg,Ti microdosimeters using liquid water phantom for clinical photon beams dosimetry

Experimental Evaluation of Depth Dose by Exit Surface Diode Dosimeters for Off-Axis Wedged Fields in Radiation Therapy

Effect of scattered radiation in the total body irradiation technique: evaluation of the spoiler and wall dose component in the depthdose distribution

Radiologic Units: What You Need to Know

Transcription:

Evaluation of 3D diamond detectors for application in medical radiation dosimetry K. Kanxheri (1,2), L. Servoli (2), C. Zucchetti (5), A. C. Dipilato (5), M. Iacco (5), S. Lagomarsino (3,4), A. Morozzi (1,2), D. Passeri (1,2), S. Sciortino (3,4) (1) Università degli Studi di Perugia, Italy; (2) INFN Perugia, Italy (3) Università degli Studi di Firenze, Italy; (4) INFN Firenze, Italy (5) Santa Maria Della Misericordia Hospital, Perugia, Italy 5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany 1

Outline Radiotherapy basics. Diamond detectors for medical dosimetry. 3D diamond detector as a dosimeter Experimental setup and measurements Conclusions. 2

Radiotherapy Basics radiation in medicine Tumour cells are not isolated, healthy tissue will also receive a high dose 3

Diamond detectors for dosimetry An ideal dosimeter Stable Linear with dose Linear with dose rate Energy independent Direction independent Fast response Good S/N ratio Minimal correction High spatial resolution CVD Diamond detectors Near Tissue equivalent (Z=6) High sensitivity Low leakage current High collection efficiency Very high carrier drift velocity, faster response High resistance to radiation damage Small volume Use CVD diamond detectors for dosimetry 4

Diamond Dosimetry State of Art PTW 60019 synthetic single crystal diamond Specifications 5

3D diamond detector as a dosimeter 3D pcvd diamond detector was produced in collaboration with the National Institute of Nuclear Physics (INFN) and the European Laboratory for Nonlinear Spectroscopy (LENS) of Florence. The resulting structure has arrays of graphitic columns of about 10 μm in diameter forming cells of 114 x 70 μm with a thickness of 0.5 mm for a total of 275 cells with a single cell sensitive volume of 0.004 mm 3 and a total diamond sensitive volume of about 1.1 mm 3. 6

1. Experimental Setup The response of the diamond detector was studied irradiating it with 6 MV photons produced by a medical linear accelerator (Clinac DBX 600 Varian) with 10 10 cm 2 field at the Santa Maria della Misericordia Hospital of Perugia. Measurements in air 2. PMMA Encapsulated 3D diamond Detector The detector was biased with a Keithley source meter 2410 and the output current is obtained by reading in parallel all the collecting graphitic columns. 7

Measurements in air - improvement in the readout system Before After Current value fluctuations ±500pA Current value fluctuations ±90pA 8

Dose Rate Dependance in Air The detector was biased with -80V Current value distribution when the detector is irradiated with 6MV photon and a dose rate of 500MU/min: The output signal of the detector is an electric current so in principle it measures dose rates. 9

Dose Rate Dependance in Air The detector was biased with -80V. Each point of the first graph rappresents the mean value of the current distribution in correspondence of different dose rates when the 3D detector is beeing irradiated with 6MV photons. The deviation from linearity is within 4%. For low dose rates (100MU/min ) the photon beam becomes partially instable. 10

Dose Rate Dependance in Air The detector was biased with -80V. The fit was obtained excluding the point at 100 MU/min from the fit. The deviation from linearity is within 0.4% indicating negligible dose rate dependence. 11

Measurements with PMMA incapsulated detector In order to reach the response stability of most synthetic diamond detectors is often required a pre-irradiation time, which can vary with the characteristics of the diamond material. The dose necessary for pumping the diamond was about 820 MU. Using an ionization chamber Farmer FC65G which was placed in the same positions as the diamond sensor, the dose necessary for pumping was equal to 7.8 Gy Conversion factor: 1 MU = 0.96 cgy 12

Linearity with dose rate - PMMA The sensor was irradiated with 6 MV photon beam for 4.5 min with 6 different dose rates 13

Linearity with dose rate - PMMA The fit was obtained excluding the point at 0.96 Gy/min from the fit. The deviation from linearity is within 1%. 14

Linearity with dose PMMA The 3D detector measures currents so the amount of charge that corresponds to each dose value has been calculated by integrating in time the current reading for a given time interval. The deviation from linearity within 1.1% is an indicator of the good time stability of the detector response. 15

Linearity with dose rate AIR vs PMMA Comparison of current readings in correspondence of some dose rate values with and without PMMA: The detector response encapsulated in the PMMA block is higher compared to the detector response in air, as it includes the backscatter radiation. 16

Voltage scan - PMMA For each point measurements were done with costant dose rate = 5.76 Gy/min costant dose = 11.52 Gy The deviation from linearity is within 0.5%. 17

Normalized charge response PMMA The 3D detector charge response normalized to the dose rate was found calculating average current after the beam and detector stabilized at 5.76 Gy min -1 and represented as a function of the bias voltage. There are 275 3D single cells, each one with a 0.004 mm 3 sensitive volume and a spatial resolution of 0.008 mm 2. At -80V the sensitivity of each cell is about 0.52 nc/gy. The commercial PTW- 60019 has a sensitive volume of 0.004 mm 3 and a spatial resolution of 4 mm 2 with a nominal sensitivity of 1 nc/gy. 18

Conclusions Results demonstrate the feasibility of 3D diamond devices for dosimetry of clinical megavoltage photon beams, showing a linear dose response, a high sensitivity and time stability. An additional work on selecting the best bias voltage in order to ensure the highest sensitivity without losing the stability of the detector is in progress. Once the present fabrication technology has been optimized, we can expect that large sensitive area polycrystalline CVD diamond segmented dosimeters will be obtainable. Due to the simultaneous measurement of many points, a higher accuracy in measurements of very small size field profiles would be possible and the need of using many not standard correction factors will be greatly reduced. 19