Analyze Dietary Fatty Acids, Sterols, and Lignans with an Agilent J&W DB-5ms UI Column

Similar documents
Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column

Column Selection for the Analysis of Fatty Acid Methyl Esters Application

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench

Rapid Separation of Fatty Acid Methyl Esters

Improving the Analysis of 37 Fatty Acid Methyl Esters

A comparison study of the analysis of volatile organic acids and fatty acids

using the Agilent 7696A Sample Prep

Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path

Determination of Adulterants in Olive Oil Analysis of Waxes and Fatty Acid Methyl and Ethyl Esters with Capillary GC and Agilent OpenLAB Software

Interested in conducting your own webinar?

Forensic Analysis of Blood Alcohol Concentration

GC/MS Identification of Flavor and Fragrance Allergens in Some Common Snack Foods Using an Agilent J&W DB-17ms Capillary GC Column

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Highly Reproducible Detailed cis/trans FAMEs Analysis Ensured by New Optimized Rt-2560 Column Manufacturing and Application-Specific QC Test

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

Organophosphorus Pesticides Analysis Using an Agilent J&W DB-5ms Ultra Inert Capillary GC Column. Application Note. Environmental. Abstract.

FATTY ACIDS IN PLASMA BY GC/MS - Code GC75010

Determination of Allergens in Fragrance Products Using Agilent Deconvolution Reporting Software Application Brief

A Rapid Method for Detection of Drugs of Abuse in Blood Samples Using the Thermal Separation Probe and the 5975T LTM GC/MS

Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis Package

Rapid Generation of Fatty Acid Methyl Ester Profiles using (Direct Analysis in Real Time) DART- Mass Spectrometry

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Chromatography Vacuum Ultraviolet Spectroscopy

INTERNATIONAL OLIVE COUNCIL

Certificate of Analysis Standard Reference Material 3275

Comprehensive analysis of FAMEs, fatty acids, and triglycerides. Agilent J&W GC columns for food nutrition testing

Trans Fat Determination in the Industrially Processed Edible Oils By Transmission FT-IR Spectroscopy By

Determination of red blood cell fatty acid profiles in clinical research

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Rapid and Robust Detection of THC and Its Metabolites in Blood

Toxicology Screening of Whole Blood Extracts Using GC/Triple Quadrupole/MS

Analysis of FAMEs Using Cold EI GC/MS for Enhanced Molecular Ion Selectivity

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

AppNote 3/2013. Automated Determination of Total Fat, Saturated Fat, Monounsaturated Fat and Trans Fat Content in Food Samples KEYWORDS ABSTRACT

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Introduction to the Study of Lipids

Improving the Analysis of Fatty Acid Methyl Esters Using Automated Sample Preparation Techniques

Lipid Analysis. Andréina Laffargue, IRD CRYMCEPT Montpellier workshop, October 17th Introduction to lipid structures

NEW! 200 m GC Columns for Detailed Analysis of cis/trans FAME Isomers

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Application. Authors. Abstract. Introduction. Forensics

GC-µECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

Fatty acid profile analysis: Grape Seed Oil Sample Set Two ( )

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

THE EFFECT OF FROZEN STORAGE ON LIPIDS AND FATTY ACIDS CONTENT IN ATLANTIC SALMON. CASE STUDY

Fatty Acid Mass Spectrometry Protocol Updated 10/11/2007 By Daren Stephens

Application note. Enabling purifications of fatty acids with Contichrom

DETERMINATION OF COMPOSITION OF TRIACYLGLYCEROLS AND COMPOSITION AND CONTENT OF DI-ACYLGLYCEROLS BY CAPILLARY GAS CHROMATOGRAPHY, IN VEGETABLE OILS

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Forensic Chemistry: Differentiation of Olive Oil and Sunflower Oil by GCxGC-TOFMS and Determination of Fraudulent Material.

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

DRAFT TANZANIA STANDARD

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

Lutein Esters from Tagetes Erecta

Proficiency testing performance of Turkish laboratories on determination of relative composition of fatty acids in sunflower oil

New GCMS Applications

Successive optimisation of waste cooking oil transesterification in a continuous microwave assisted reactor

DETERMINATION OF FATTY ACIDS IN EDIBLE OILS BY CAPILARY GC

AS Application Note 1602

NUTRITIONAL COMPONENTS OF SUPERCRITICAL CARBON DIOXIDE EXTRACTED WHEAT GERM OIL

AOAC Official Method Determination of Labeled Fatty Acids Content in Milk Products and Infant Formula

Authors. Abstract. Introduction. Environmental

Supplementary information on testing by participating laboratories:

A Novel HILIC Column for High Speed N-linked Glycan Analysis

Direct Analysis of Lipophilic Antioxidants of Olive Oils using Bicontinuous Microemulsions

ANSC 619 PHYSIOLOGICAL CHEMISTRY OF LIVESTOCK SPECIES. Lipid Chemistry NO. OF CARBONS COMMON NAME GENEVA NAME STRUCTURE

Analysis of the fatty acids from Periploca sepium by GC-MS and GC-FID

A MODIFICATION OF GAS CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF FATTY ACID COMPOSITION OF MILK FAT

The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

Fast determination of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 1260 Infinity Analytical SFC System

Concentrating Alpha-tocopherol from Oil Byproduct with Supercritical Methanol and CO 2

Fatty Acid Methylation Kits

VOLUNTARY MONOGRAPH. Council for Responsible Nutrition March 2006

Organophosphorus Residues in Olive Oil by GC/FPD with Agilent J&W DB-35ms Ultra Inert

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Relative Measurement of Zeaxanthin Stereoisomers by Chiral HPLC

Application Note. Abstract. Authors. Pharmaceutical

2D-LC as an Automated Desalting Tool for MSD Analysis

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Time-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium. Application. Authors. Abstract.

Application Note. Authors. Abstract. Petrochemical

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Application Note. Author. Abstract. Introduction. Food Safety

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Why use Signal-To-Noise as a Measure of MS Performance When it is Often Meaningless?

A Rapid Method for Trans-Fatty Acid Determination Using a Single Capillary GC Seiichi Shirasawa, Akiko Sasaki, Yasue Saida and Chiemi Satoh

Supplementary Material. Biomimetic chemistry on the protection of cis phospholipid from the thiyl radical isomerization by common antioxidants

Column Chromatographic Isolation of Docosahexaenoic Acid from Fish Oil and its Assessment by Analytical Techniques

CORESTA Recommended Method No. 84

Direct determination of MCPD esters and glycidyl esters by LC-TOFMS

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System

Transcription:

Analyze Dietary Fatty Acids, Sterols, and Lignans with an Agilent J&W DB-ms UI Column Application Note Foods Testing & Agriculture Authors Pat Sasso and Ken Lynam Agilent Technologies, Inc. Abstract The introduction of Agilent J&W Ultra Inert (UI) capillary GC columns and the improved peak shape they afford suggested that it was possible to determine fatty acid profiles without the need to make the fatty acid methyl esters (FAMEs). The Agilent 7696A Prep WorkBench was, therefore, used to prepare canola and extravirgin olive oils for analysis of fatty acids as their hydrolysis products. Sterols and lignans were coextracted and assayed in their native form. Completion of the reaction was monitored on an Agilent J&W DB-ms UI GC column. Acceptable peak shape was demonstrated for unsaturated fatty acids up to docosanoic acid (C22). Resolution of oleic (C8:) from stearic (C8:0) acid in a typical sample was achieved. Introduction While good peak shape for methyl esters and improved volatility relative to free fatty acids is advantageous, the ability to use tools, such as negative mode electrospray, provides a viable detection technique for organic acids in HPLC. These compounds have low wavelength UV chromophores that would present challenges if common HPLC mobile phases or buffers were used to adjust resolution. Having the ability to prepare samples for either GC or HPLC offers greater flexibility to complete analytical tasks, saving time and resources. Many modern laboratories engaged in dietary nutritional labeling are equipped with gas and liquid chromatography, and the use of LC/MS has increased dramatically. While the fatty acid profile for all consumer animal and vegetable fats is well established [], the ability to hydrolyze these water-immiscible, highly viscous substrates presents a challenge for automated liquid handling systems. The 7696A Prep WorkBench performs all of the

steps in the sample preparation once the samples are weighed accurately and mixed in a : ratio with hexane. The hydrolysis technique that works best is saponification with NaOH in a : mole ratio, but this requires considerable time, at least 2 hours. This sample prep bottleneck is alleviated by batching as many as 20 to 0 samples and letting the automation run overnight unattended. Run times on the gas chromatography assay are approximately 0 minutes and permit the monitoring of unreacted vegetable oil triglycerides [2]. Materials and Methods An Agilent 7890A Series GC was coupled to an Agilent 97C Series GC/MSD System with the Inert EI 0 noncoated source. A similar setup using an FID detector was used for crude reaction monitoring. Conditions GC conditions Column: Agilent J&W DB-ms UI, 0 m 0.2 mm, 0.2 µm (p/n 22-2UI) Sample preparation Sample: Canola oil, extra-virgin olive oil saponified, and hexane extracted Carrier: MSD helium, FID hydrogen for reaction monitoring, both at.0 ml/min constant flow Oven: 20 C (hold min, to 2 C at 20 C/min (hold 20 min) Injection: Split/splitless, 00 ml/min split flow with gas saver on at min, ml/min purge flow Inlet temperature: 280 C Detector: FID for reaction monitoring at 2 C MSD transfer aux temperature: 2 C GC: Agilent 7890A Series GC Sampler: Agilent 769 Automatic Liquid Sampler, µl syringe 0. µl injection, split 20: MS conditions MS: Agilent 97C Series GC/MSD System with EI inert 0 source, tandem axis detector Solvent delay: min MS temperature: 00 C (source); 0 C (quad) Scan range: 0 to 0 Flow path supplies Vials: Amber screw cap (p/n 82-076) Caps: Blue screw cap (p/n 282-072) Vial inserts: 20 µl glass with polymer feet (p/n 8-270) Syringe: µl (p/n 8-27) Septum: Red Bleed Temp Optimized BTO (p/n 8-77) Inlet liner: Dual Taper Direct Connect (p/n G-80700) Magnifier: 20x (p/n 0-020) Standards preparation A six-component checkout mix at 0 ng/µl in hexane consisting of C2 through C22 was used to provide a column evaluation for peak shape up to the maximum allowable operating temperature of the column. The compounds can be purchased as pure standards in kit form from Grace (even carbon number p/n 8602) as 00 mg per compound. Pinoresinol was obtained from Sigma-Aldrich Corp. (catalog number SML-007-MG). Figure demonstrates that chromatographic peak shape was visually acceptable for all components in the standard mix. 2 2.00.00.00.00 6.00 7.00 6. Dodecanoic acid C2:0 2. Tetradecanoic acid C:0. n-hexadecanoic acid C6:0. Octadecanoic acid C8:0. Eicosanoic acid C20:0 6. Docosanic acid C22:0 8.00 9.00 0.00.00 Figure. TIC of six-component free fatty acids evaluation mix. 2

Sample preparation Vegetable oil samples for analysis were reacted/saponified and extracted using the 7696A Prep WorkBench, left to run overnight, and left unattended. Fish oil capsules high in omega- FAMEs were cut open with a razor. Their contents were washed with water, and hexane was extracted to remove glycerol from the formulation; no saponification was needed. Isolation of extra-virgin olive oil lignan markers was completed by multiple liquid/liquid extraction [] in two steps with hexane:methanol and hexane:acetonitrile. Figure 2 shows a screen capture of the 7696A Prep Workbench parameters. This system allows for numerous reaction condition variations. The main problem to overcome is that the reactant oils separate from the aqueous NaOH solution. The conversion to acids can be brought to approximately 90% completion, providing sufficient quantity of the acids to allow accurate profiling as compared to reported values []. Figure 2. Agilent 7696A Prep WorkBench reagents and temperatures for hydrolysis.

Figure shows the early crude reaction at 0% with elution of the unreacted mono-, di-, and triglycerides at the end of the chromatographic run. C8: Results and Discussion Table shows the peak width and tailing factor for the peaks shown in Figure, as calculated by Agilent ChemStation software. While the peak widths are considerably greater for the free acids than would be expected for the methyl esters, in the case of canola and olive oil, the separation of main constituent oleic acid (C8:) from a trace amount of stearic acid (C8:0) is readily demonstrated in Figure. Separation of cis and trans isomers would require cyano functional group stationary phases, which are available in both gas and liquid chromatography columns. For C8 isomers, separation of their methyl esters can be achieved by GC using the Agilent J&W Select FAME stationary phase (p/n CP72). Naturally occurring oils contain double bonds only in the cis configuration [] but can be isomerized during processing and purification. Recovery and separation of the plant sterols, including vitamin E (tocopherol), can be seen in the TIC trace in Figure. C8:0 0.0.20.0.0.0.60.70.80.90 6.00 6.0 6.20 6.0 6.0 Figure. Separation of critical pair oleic (C8:) from stearic (C8:0) acid. 0 6. n-hexadecanoic acid C6:0 2. 9-Octadecenoic acid, (Z)-C8:. Octadecanoic acid C8:0. 9,2-Octadecadienoic acid, (Z,Z)-C8:2. Oleic acid, -hydroxypropyl ester 6. 9,2,-Octadecatrienoic acid, (Z,Z,Z) C8: 7. Tocopherol 8. Stigmasterol 9. Campesterol 2 0. Sitosterol.00 0.00.00 20.00 Unreacted di-and triglyceride 2.779 26.0 2.00 0.00.00 Figure. Agilent 7696A Prep WorkBench reaction at approximately 0% completion using GC conditions to elute all reactants. Abundance 2.00.00.00.00 6.00 6 7 8 9 0 7.00 8.00 9.00 0.00.00 2.00 Figure. TIC trace of hydrolyzed canola oil showing all fatty acids and plant sterols. Table. Calculation of peak width and tailing factor. Component Peak width Tailing C 2 Dodecanoic acid 0.2 0. C Tetradecanoic acid 0.90 0. C 6 n-hexadecanoic acid 0.72 0.7 C 8 Octadecanoic acid 0.28 0.6 C 20 Eicosanoic acid 0.28 0.8 C 22 Docosanoic acid 0.9 0.7

The extra virgin olive oil lignan markers, pinoresinol and -acetoxyresinol, are shown as trace components in Figure 6, along with their EI spectra. These two compounds are not present in the recent NIST mass spectral library. Peak shape for the fish oil omega- esters of DHA (docosahexaenoic acid) and EPA (eicosapentaenoic acid) can be seen in Figure 7. 0Abundance 2.00 0.00.00 20.00 6 7 8. Palmitoleic acid 2. Palmitic acid. Oleic acid. Stearic acid. Glycerol -palmate 6. Glycerol -oleate 7. Squalene 8. Sitosterol 9. Pinoresinol 2.00 0.00.00 9 Figure 6. TIC trace of hydrolyzed extra virgin olive oil showing fatty acids and lignan markers with EI spectra. -Acetoxypinoresinol Pinoresinol 00 20 00 8 0 2 09 0 09 9 7 0 6 60 20 80 20 00 60 20 80 0 8 60 20 80 20 00 60 20 80 0Abundance 2 6. Ethyl oleate 2. Ethyl stearate. EPA ethyl ester. EPA isopropyl ester. DHA ethyl ester 6. DHA isopropyl ester 2.00.00 6.00 8.00 0.00 2.00.00 6.00 8.00 20.00 22.00 Figure 7. TIC trace of commercial fish oil omega- esters amenable to LC/MS with Atmospheric Pressure Chemical Ionization (APCI).

Conclusions The Agilent J&W DB-ms Ultra Inert GC column provides acceptable peak shape for free fatty acids. The ability to leverage both column chemistry and automated sample preparation permits flexibility to transfer the assay from GC/MS to LC/MS, with the potential to improve overall productivity and laboratory throughput by expanding instrumental resources beyond their typical application scope. In the normal evolution of analytical assays, sample preparation often becomes customized and provides numerous challenges. Removing obstacles such as cumbersome sample preparation always provides a step in the right direction toward increased laboratory productivity. For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. Acknowledgement The authors wish to thank Rebecca Veeneman for her generous donation of fatty acids to enable the chromatographic evaluations. References. S. Rossi. Does Canola Oil Have Omega-6 Fatty Acids? Livestong Foundation. http://www.livestrong.com/article/ 00-does-canola-oil-have-omega-6-fatty-acids/ 2. N. Helle, M. Bzduch, R. Veeneman. Determination of Fatty Acid Methyl Esters (FAMEs) in Salmon Oil Using Automated Sample Preparation. Application Note, Agilent Technologies, Inc. Publication Number 990-9799EN (202).. M. Brenes, F. J. Hidalgo, A. García, J. J. Rios, P. García, R. Zamora, A. Garrido. Pinoresinol and -acetoxypinoresinol, two new phenolic compounds identified in olive oil. J. Am. Oil Chem. Soc. 77, 7 (2000).. Fatty acids content in dietary fats. Wikipedia. http://en.wikipedia.org/wiki/fatty_acid. AOAC. AOAC Official Method 2000.0. AOAC International, Gaithersburg, MD, USA. http://www.aoac.org/vmeth/ E_methodEX2000.0.PDF www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 20 Printed in the USA January 0, 20 99-7EN