Noise Measurement. Solutions

Similar documents
Please recycle. Printed in Sweden. 3M All rights reserved.

3M Hearing Conservation. Make sure your workers are protected with the 3M 4-step approach

3M Occupational Health and Environmental Safety Division 3M NoisePro Personal Noise Dosimeter. NoisePro Series. Quick Start Guide

UltraFit 12. Click for Attenuation Ratings: UF

Model Safety Program

3M E-A-Rfit Validation System. FitTesting. for Hearing Protectors. Leading the Advancement of Hearing Conservation

Reliable, flexible & precise

CCS Administrative Procedure H Hearing Conservation

3M Personal Safety 3M Peltor X Series Ear Defenders. A new Standard. in Design, Comfort. Protection.

3M Center for Hearing Conservation

Before taking field measurements, it is important to determine the type of information required. The person making the measurement must understand:

Hearing Loss Prevention PM Session Ted Madison

North Dakota State University Noise/Hearing Conservation

HEARING PROTECTION PRESERVE & PROTECT

Hearing protection for the metal industry

Workplace hearing loss is preventable.

HEARING CONSERVATION PROCEDURE

Health, Safety, Security and Environment

Hearing Conservation Terminology Courtesy of Workplace Integra, Inc.

HEARING CONSERVATION PROGRAM

Hearing Solutions Catalog Winter Supplement January 2009

Hearing Conservation Program

Hearing Conservation Program Regulations and Recommendations Summary

TAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM

Conservation in the. Hearing. Oil & Gas Industry. The power to protect your world. SM. 3M Personal Safety Division Hearing Conservation Solutions

Hearing Conservation Program

Hearing Conservation Program April 27, 2018

OVER 100 YEARS EXPERIENCE IN EVERY STITCH

Santa Clarita Community College District HEARING CONSERVATION PROGRAM. Revised

Environmental Health & Safety Policy Manual

Workplace Noise Surveys: A Hands-On Measurement Workshop

Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003

CITY OF FORT BRAGG HEARING CONSERVATION PROGRAM

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017

11. Hearing Conservation Program Chapter , WAC

Solutions Made. Conservation in the. Hearing. Innovatively Easy. Hearing Protection. Oil & Gas Industry. The power to protect your world.

Six Components of Hearing Conservation Program. Helene R. Freed, Ed.M Public Relations Specialist Industrial Hearing Testing

Hearing Conservation Program

Environmental Health & Safety Programs

HEARING CONSERVATION PROGRAM Texas Christian University

Protect lives from the pain of hearing loss

UC Merced Hearing Conservation Program

Hearing Conservation Program

HEARING CONSERVATION PURPOSE

HEARING CONSERVATION PROGRAM

ACOUSTIC INFRASOUND AND LOW-FREQUENCY SOUND

Hearing Conservation Program

Delaware State University

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Hearing Conservation Program. Santa Clara University 500 El Camino Real Santa Clara, CA 95053

Hearing Conservation Program

Environment CAUTION HEARING PROTECTION REQUIRED. Occupational Noise Exposure Requirements for Photographic Processing Facilities

Hearing Protection Systems

ENDODONTICS ENDODONTICS

Craven Community College HEARING CONSERVATION PROGRAM

Purpose: To provide a process to protect employees from hearing loss caused by excessive occupational exposure to noise.

INDH 5131 Controls of Occupational Hazards. Noise & Hearing Conservation. Part II. V. Audiometric Testing

myaudiometer. It s familiar, and it s so much

This program is designed to prevent hearing loss for students, staff and employees while engaged in universitysponsored

ENDODONTICS ENDODONTICS

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Noise Monitoring. T. Renée Anthony, PhD, CIH, CSP University of Iowa, College of Public Health

But there is good news most hearing damage is preventable.

Contents. 1) Purpose ) Policy ) Definitions ) Procedure a) Requirements b) Noise standard... 4

Hearing Protection. Because we all are different. Electronic Earmuffs. left/right CutOff. left/right Dual. left/right FM Radio

Occupational Noise Exposure

Noise at Work Regulations. Mick Gray MRSC, LFOH, ROH. MWG Associates Ltd

Current Issues in Hearing Loss Prevention

Hearing Conservation Program

HEARING CONSERVATION PROGRAM

Standard. and Protection. A new. in Design, Comfort. The power to protect your world.

THE SOLUTION REVOLUTIONARY TO NOISE PROTECTION

Hearing Conservation Services Specifications

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

DISPOSABLE EARPLUGS. HIGH VISIBILITY COLOR A very bright orange plug color makes compliance checks easy and quick.

MA 25 Operating Manual

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

User Guide. For Jacoti Hearing Center Version 1.1. Manufacture Year 2016

INTERNATIONAL MODULE SYLLABUS W503 NOISE MEASUREMENT AND ITS EFFECTS

Safety Services Guidance. Hearing protection

Oscilla - excellence since 1960

ERO SCAN. Otoacoustic Emission Testing

CERTIFICATE OF COMPETENCE IN WORKPLACE NOISE RISK ASSESSMENT

! Caution (continued)

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

BEAUFORT COUNTY COMMUNITY COLLEGE OCCUPATIONAL NOISE

SOUTHERN UTAH UNIVERSITY S WRITTEN HEARING CONSERVATION PROGRAM December 2017

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

100% Preventable. HEARING. Hearing and Noise Reduction Overview

HEARING CONSERVATION PROGRAM

East Carolina University

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

HEARING LOSS PREVENTION PROGRAM AND PROCEDURES

Transcription:

Noise Measurement Solutions Occupational Health & Environmental Safety Division EMEA Region 3M United Kingdom plc Customer Technical Centre Easthampstead Road Bracknell, Berkshire RG12 1JE, England Phone: (44) 1344 866 458 Fax: (44) 1344 866 495 Internet: www.3m.eu/safety Please recycle. Printed in Sweden. 3M 2011. All rights reserved.

Noise Measurement Noise is one of the most prevalent occupational health hazards found in the workplace. It can cause permanent hearing loss, reduce worker concentration and inhibit communications, which may increase the risk of injury or even death. Occupational hearing loss is a serious problem, while it can be easily avoided. Therefore, accurate noise monitoring is an important component of a hearing conservation program. 3M noise meters provides users with easy, durable noise detection, helping identify where hearing protection may need to be worn. The meters range from basic and advanced sound level meters to noise dosimeters. Hearing Conservation 3M brings together the leading brands in hearing conservation. Quest, E-A-R, Peltor and 3M brands provide you with the most complete Hearing conservation programme to ensure detection of noise, protection for your employees and validation of their hearing protectors. All this for a single purpose : your safety. Detection, protection and validation - now you have easy, single source access to the most complete line of industry-leading hearing conservation products: Detection Protection Validation 2 3

3M Entry Level Sound Detection 3M Sound Detector SD-200 with Optime Alert System Linkage Easily Select hearing protection The Sound Detector SD-200 is a compact, lightweight sound level meter designed to accurately measure workplace noise levels. Green, yellow and red LEDs flash the colour that corresponds to the Optime Alert System, making it easy to select the appropriate level of hearing protection. 3M Sound Examiner NEW! 3M Sound Examiner Sound Level Meter SE-400 The Sound Examiner SE-400 series of sound meters are engineered (LEQ/LAVG) over the run time, helping you to more accurately assess to accurately measure noise levels in highly variable environments. occupational and environmental noise levels. These advanced instruments compute the average sound pressure level + + Integrating feature computes the average sound pressure level; allows for more accurate assessment of intermittent sound levels + + User-friendly interface; easy to operate + + Rechargeable lithium polymer battery helps lower Total Cost of Ownership compared to the use of replaceable batteries + + Average sound pressure level delivers steadier reading where noise levels are variable Flashing LEDs match Optime Alert System Easy to read screen: + + Sound Pressure Level (SPL), Average value (L EQ /L AVG ), Optime Alert (with Hearing Protection icon), Maximum value 5MAX), Minimum value (MIN), Run-Time, Overload 5OL), and Under-Range 5UR) + + 45 to 130dB (Dynamic Range) + + A or C Easy five button operation + + Available in Class 1 Precision or Class 2 General Purpose models + + Complies with IEC and ANSI Standards + + Integrating-averaging measurements + + All models ship ready-to-use, no setup necessary + + Use 3M Detection Management Software DMS for the analysis, management and measurement of data Integrating Measurements, Robust Capabilities + + Display Languages: English, Spanish, German, French, Italian, Portuguese Detection Management Software: One System supporting all these applications: + + Noise Dosimetry + + Octave Band Sound + + Analysis/Survey + + Thermal Comfort Monitoring + + Integrating Sound Level Meter + + Industrial and Community Sound Surveys + + Heat Stress Monitoring + + Indoor Air Quality Assessment + + Display SPL, LMAX, LMIN, Peak, Lavg/ Leq, Elapsed Time 3M Noise Indicator NI-100 The 3M Noise Indicator alerts users to potentially dangerous noise The Noise Indicator s small size and lightweight design make it ideal for levels, helping to identify areas where hearing protection may need to workers in a variety of industries. be worn. Users simply clip the Noise Indicator to a shirt or jacket; its LED light delivers a clear indication when noise levels exceed a potentially hazardous threshold. + + Clips to wearer s shirt or can be worn on a lanyard + + Small size and lightweight, durable design + + Easy to use, with a single button on/off switch + + Rechargeable battery, with up to 200 hours between charges + + Alerts users to potentially dangerous noise levels + + Helps identify where hearing protection may be needed Green Flashing LED: + + Noise levels are below 85dB(A) hearing protection may not be necessary. Red Flashing LED: + + Noise levels are above 85dB(A) hearing protection may be required. New DMS Software: Data Management Made Easy For Environmental Monitoring, Heat Stress and Sound Level Measurements, and Dosimetry. The new 3M Detection Management Software (DMS) makes it easy to export, report, and share data from the SE-400 series sound meters, and other 3M Quest instruments. The software will help improve both efficiency and reporting of environmental data + + Retrieve, download, share and save instrument data + + Generate charts and reports + + Export and share recorded data + + Perform advanced calculations + + Program, retrieve and view real-time data remotely via modem 4 5

3M SoundPro Sound Level Meters SE/DL 3M The Edge Cable Free Noise Dosimeters The 3M SoundPro SE/DL series provides advanced sound level Now there s a new, more innovative family of personal noise dosimeters. With The Edge there s no cable to interfere with your employees work, monitoring and comprehensive data analysis. Available in Class 1 and Available in three models, The Edge offers advanced technology and no heavy instrument loading them down. This innovative dosimeter Class 2 models, these instruments feature real-time frequency analysis, packaged in a cable-free, compact frame for a lighter, more ergonomic weighs a mere 3 ounces and features a thin, contoured shoulder mount. and data storing capabilities that make it easy to post-process and way to monitor noise levels. Users will barely notice it as they work; yet with easy downloading, evaluate workplace noise levels. simple. + + ANSI and IEC standards compliant + + Available in Class 1 Precision or Class 2 General Purpose models + + Concurrent A-weighted and C-weighted measurements + + A, C, Z and F (Flat) frequency weighting + + Fast, slow, and IEC impulse time response + + Selectable thresholds 10 db 140 db + + Optional downloads to 3M Detection Management Software DMS offer analysis, management and measurement of data + + Multilingual display in English, French, Spanish, German, Italian & Portuguese + + Display SPL, Dose, Lavg or Leq, TWA, Max, Min, Peak, Exposure, Run Time, and more Class 1 Precision and Class 2 General Purpose Models Available SPL Display Quasi-Analogue and Numeric Screen 1/1 Octave Band Bar Chart Measurement Screen + + Convenient cable-free design eliminates the microphone cable and potential to get in the way + + Thin, contoured mount hugs the shoulder + + Compact frame offers superior comfort small size and lightweight, durable design + + Rechargeable lithium battery gives The Edge its long battery life + + Downloads to 3M Detection Management Software DMS offer analysis, management and measurement of data + + Display SPL, Dose, Lavg or Leq, TWA, Max, Min, Peak, Exposure, Run Time and more + + The Edge eg5 has 3 independent dosimeters, is intrinsically safe and offers simultaneous C-weighted and A-weighted measurements. Two Affordable models: + + The Edge eg5 has 3 independent dosimeters and data logging. It stands apart as an intrinsically safe dosimeter that offers simultaneous C-weighted and A-weighted measurements. + + The Edge eg4 advanced model has dual dosimeters and data logging/time history. + + Large screen display enables real-time frequency analysis + + Easy to read back-lit display + + Menu driven, 4 soft keys 1/3 Octave Band Bar Chart Measurement Screen + + Displays SPL, Dose, Lavg or Leq, TWA, Max, Min, Peak, Exposure, Run Time and more + + 1 or 5 bay docking stations offer quick, easy recharge and data download to a PC SoundPro Outdoor Measuring System SP-OMS The SoundPro Outdoor Measuring System helps protect the instrument from exposure to wind, rain, snow, chemicals, particulates, animals, vandalism and theft. It is also used for extended battery life with up to one week of continuous monitoring (two weeks with optional second battery). Other Options: Full (1/1) octave band real-time analysis Third (1/3) octave band real-time analysis Acoustic spectral curves option Speech intelligibility option Audiometric calibration kit configurations GPS data incorporation Optional microphones in 1/4", 1/2" & 1" Reverberation Time (RT-60) 6 7

3M E-A-Rfit Validation System 3M Acoustic Calibrator AC 300 The AccoustiCal AC-300 is a precision solution particularly suited for calibration of Class/Type 1 microphone. It generates two settings with either 250 Hz or 1000 Hz at a sound pressure level of 114dB. The sound pressure level and combinations of frequency outputs conform to the requirements of the IEC standard 60942: 2003-1 for sound calibrators. Technology That Takes Hearing Conservation To The Next Level Stop guessing what protection levels your Workers are really getting from their earplugs. Start knowing each worker's personal protection level and Validate that they are getting the protection they need. Ear canal shapes are different. Fitting methods are different. That means protection levels may be different. With the E-A-Rfit validation system, you can : Validate protection levels achieved by each worker Document data for future reference + + Calibrates precision Class/Type 1 sound level meters and noise dosimeters + + Produces two signals: 250 Hz or 1000 Hz at a sound pressure level of 114.0 db + + Long battery life + + Low Battery indicator + + Conforms to the requirements of the IEC standard 60942: 2003-1 for sound calibrators + + Conforms to ANSI S1.40-1983 (R2006f): Specifications and verification procedures for sound level meters Innovation F-mire Process Is Quick, Simple and Accurate Unlike less reliable tone response tests, E-A-RFit is an F-MIRE (field-microphone-in-real-ear) test system. Key features to this innovative system are: Exclusive Probed Hearing Protectors Most Hearing protectors can be tested with this system. Dual Elements Microphone Measures sound inside and outside the ear. Advanced Algorithm Utlises transfer function measurement approach to acquire reliable data in less than eight seconds. Proprietary and Patented Application Software Provides enhanced metrics for guidance in the application of the measured insertion loss values. E-A-Rfit Compatible Earplugs The E-A-Rfit subject fits their own protector, the technician connects the microphone to the hearing protetor, leaving the other exposed so that noise levels are measured inside and outside the ear. Personal Attenuation Rating (PAR) For Each Worker In Minutes It only takes eight seconds to calculate data at seven standard (125Hz to 8000Hz) frequencies. You'll know exactly what level of protection each worker receives from each tested protector. No guesswork. Data Is Documented For Future Reference Each worker's PAR results will be automatically documented and stored by the technician. This information is valuable for comparison during subsequent tests. A copy of the results will also be provided to your company's Hearing Conservation Manager. 8 9

Test Compatible With A Variety Of Hearing Protectors 3M European Service Centre Protection levels can be validated with many differnt hearing protectors. This selection includes specially-probed versions of our 3M Quest Technologies instruments are warranted to be free from defects For Noise measurement instruments, the laboratory is working to 3M's most popular hearing products. in materials and workmanship for one year under normal conditions of use internationally developed and accredited procedures. and service. We recommend an annual calibration to ensure the proper 3M E-A-Rfit Compatible Earplugs Push-Ins 3M 1100/1110 36dB to national standards - all our calibrations are traceable. The team has many years experience in the support of a wide range of 3M and 3rd party scientific, laboratory, medical and industrial instruments. The 28dB E-A-Rsoft FX 3M has a dedicated service centre based in the UK which is fully equipped service, calibration and repair facilities. E-A-R Express E-A-Rsoft The service centre uses calibration equipment which is routinely calibrated to support all customers thoughout Europe, Middle East and Africa with 38dB 37dB performance and precision of your instruments. centre has achieved ISO9001, ISO17025 and UKAS accreditation. Ultrafit 39dB 32dB 3M Runcorn Classic 28dB Annual Calibrations Key Features: 5 Seymour Court, Manor Park, Runcorn, WA7 1UZ Ultrafit 14 ++ Factory product warranty extension for additional 12 months Tel: 00 44 1928 532590 14dB ++ Factory hardware and firmware updates Fax : 00 44 1928 597 769 automatically installed ++ Assurance intrinsic safety approvals are not voided E-mail: 3mruncorn@mmm.com by unapproved repairs or modifications Ultrafit 20 Classic Small ++ Calibration measurements are traceable 20dB 28dB Superfit 33 Tracer 33dB 32dB Classic Corded Tracer 20 29dB 20dB End to End Compliance Program from 3M Measurement Products Training Suport 10 Validation 11