THE LEVEL OF COMPLIANCE OF SELECTED NIGERIAN X-RAY DEPARTMENTS TO EUROPEAN GUIDELINES ON GOOD RADIOGRAPHIC TECHNIQUES

Similar documents
Radiation Doses to Patients Undergoing Selected Radiographic Examinations in Three Hospitals South-West, Nigeria

Patient dose in routine X-ray examinations in Yazd state

Radiation Protection Dosimetry Advance Access published April 22, 2008

A Standardised Approach to Optimisation

Survey of dose area product received by patients undergoing common radiological examinations in four centers in Nigeria

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA

Radiation exposure of the Yazd population from medical conventional X-ray examinations

Survey Effect of the Corrective Actions and Quality Control in Image Quality and Patient Dose in Radiography Examinations

A Survey of Radiation Exposure Techniques Factors Used for Common Diagnostics X- Ray Examinations in Akwa Ibom State, Nigeria

PATIENT ENTRANCE SKIN DOSES AT MINNA AND IBADAN FOR COMMON DIAGNOSTIC RADIOLOGICAL EXAMINATIONS

Research Article. Corresponding author H. Osman

Establishing a quality assurance baseline for radiological protection of patients undergoing diagnostic radiology

Receptor dose and Patient Dose in Radiographic exposures - a 15 year review

Doses Received by Patients during Thorax X-Ray Examinations

Impact of quality control on radiation doses received by patients undergoing abdomen X-ray examination in ten hospitals

Patient doses in radiographic examinations in Western and Eastern Azerbyjan provinces of Iran

Local reference dose evaluation in conventional radiography examinations in Iran

Assessing the standard dose to standard patients for x-ray investigations

ABSTRACT I. INTRODUCTION

An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan

Quality Assurance and Optimization of Radiation Protection of Patients in X-Ray Radiographic Examinations Using the Rejects Film Analysis

Evaluation of radiation dose and image quality following changes to tube potential (kvp) in conventional paediatric chest radiography

Iranian Journal of Medical Physics

Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, Iran

P T.Ishiguchi 1, S.Iwanami 2, S.Kawatsu 1, T.Ishigaki 1 and S.Koga 3

OPTIMISATION OF PATIENT PROTECTION AND IMAGE QUALITY IN DIAGNOSTIC RADIOLOGY

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

RADIATION DOSES TO PATIENTS UNDERGOING BARIUM MEAL AND BARIUM ENEMA EXAMINATIONS

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Patient doses in general radiography examinations

Radiation Protection Dosimetry Advance Access published September 13, 2006

International Journal of Radiation Research, January 2017

The impact of SID and collimation on backscatter in radiography

Entrance Surface Dose from Pediatric Diagnostic X-ray Examinations in a Developing World Setting: Are We ALARA Principle Compliant?

THE STUDY OF PATIENT DOSES IN DIAGNOSTIC RADIOLOGY FOR ESTABLISHMENT OF NATIONAL DIAGNOSTIC REFERENCE LEVELS

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Application of dose-area product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 6, 2016

Assessment of radiation risk to pediatric patients undergoing conventional X-ray examinations

Assessment of effective dose in paediatric CT examinations

A STUDY ON SOME PHYSICAL PARAMETERS RELATED TO IMAGE QUALITY AND RADIATION SAFETY IN DIAGNOSTIC RADIOLOGY

ICRP Symposium on the International System of Radiological Protection

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

EVALUATION OF EXPOSURE INDEX (lgm) IN ORTHOPAEDIC RADIOGRAPHY L. Lança 1, * and A. Silva 2

IAEA-TECDOC-796. Radiation doses in diagnostic radiology

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Patient dose measurement in common medical X-ray examinations in Iran

Establishment of local diagnostic reference levels for quality control in intraoral radiography

Measurement of Kidneys Dose in Three Hospitals during Chest and Abdomen Radiographic Examinations

Estimation of Radiation Absorbed Dose to Patients Undergoing Chest X-ray Examination in Four Government Own Hospitals in Nigeria

Shielding Calculation: Radiographic Room. Jerry Williams

IRMER Ionising Radiation Medical Exposure Regulations

Survey of patients CT radiation dose in Jiangsu Province

JMSCR Vol 06 Issue 12 Page December 2018

Doses to Patients arising from Dental X-ray Examinations in the UK, A Review of Dental X-ray Protection Service Data

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Evaluation and Optimization of Exposure Index in Lumbar Spine and Pelvis X-Ray

Diagnostic Reference Levels (DRLs)

Equivalent dose to organs and tissues in Hysterosalpingography calculated with the FAX (Female Adult voxel) phantom

The use of gonadal shielding in singular common diagnostic radiographic procedures

The checklist for the use of Ionising Radiation in Primary Dental Care. Not fully compliant

K E M Mohamadain 1,6,LARdaRosa 2, A C P Azevedo 1, M R N Guebel 3, M C B Boechat 4 and F Habani 5

Diagnostic reference levels as a quality assurance tool

MA 2030 Radiography Skills for Medical Assistants

Limited information related to: - Type and frequency of procedures; - Exposure levels involved.

INTER-AMERICAN UNIVERSITY OF PUERTO RICO

Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement

Trends in Patients Exposure Doses during Radiographic Examination in Japan

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Measurement of Absorbed Doses in Anatomical Phantoms

Population Dose from General X-ray and Nuclear Medicine: 2010

The Fluoroscopic Technique for Monitoring Distraction of a Non-Invasive Lengthening Device in Early Onset Scoliosis

Radiation Dose Assessment and Risk Estimation During Extracorporeal Shock Wave Lithotripsy

Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

Diagnostic reference levels in intraoral dental radiography in Korea

Evaluation of the doses delivered to premature babies in the Belgian Neonatal Intensive Care Units

Entrance Surface Air Kerma for Skull, Pelvis and Abdomen X-ray Examinations in Some Diagnostic Radiology Facilities in Akwa Ibom State, Nigeria

Introduction and Background

Dental Intraoral X-ray Systems

Information and Guidance

Olowookere, C.J. Dept of Physics Ajayi Crowther University, Oyo

Efficacy of Increasing Focus to Film Distance (FFD) for Patient s Dose and Image Quality in Pediatric Chest Radiography

HCTC/SKCTC Regional Radiography Program. IMG Course Descriptions and Student Learning Outcomes

Medical Physics and Informatics Original Research

Trends in examination frequency and population doses in Norway,

Iranian Journal of Medical Physics

Radiation Safety. - Orientation Session - Environmental Health, Safety & Risk Management Health Physics Services Unit

Ask EuroSafe Imaging Tips & Tricks. CT Working Group. On the use of Diagnostic Reference Levels in CT

Dental Extraoral X-ray Systems

1 Course Syllabus + Study Guide for Lecture and Laboratory

The effect of breast shielding during lumbar spine radiography

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Managing Patient Dose in Computed Tomography (CT)

Report. Surveying dose levels for computed radiography in the UK. KCARE King s College Hospital Denmark Hill London SE5 9RS

Evaluation of a Digital Measurement Tool to Estimate Working Length in Endodontics

PNRA-RG (Rev. 0) December, 2017 PROTECTION OF PATIENTS IN DIAGNOSTIC RADIOLOGY REGULATORY GUIDE PAKISTAN NUCLEAR REGULATORY AUTHORITY

ROMANIA MEDICAL EXPOSURE IN 2016 IN ROMANIAN RADIOLOGICAL DEPARTMENTS. Olga GIRJOABA and Alexandra CUCU

Transcription:

IJRRAS 9 (1) October 11 www.arpapress.com/volumes/vol9issue1/ijrras_9_1_16.pdf THE LEVEL OF COMPLIANCE OF SELECTED NIGERIAN X-RAY DEPARTMENTS TO EUROPEAN GUIDELINES ON GOOD RADIOGRAPHIC TECHNIQUES Bamidele L. 1 & Nworgu O.D. 2 1 Department of Mathematics & Statistics, Osun State College of Technology, Esa-Oke. 2 Department of Physics, University of Benin, Nigeria E-mail: bam7ng@yahoo.com ABSTRACT European directive (particularly the directive 97/43/EURATOM) and the various publications of Commission of European Communities (CEC) may be considered as landmarks of the new approach to the problems of dose reduction and quality in diagnostic radiology. The CEC publication includes examples of good radiographic technique for a number of common X-ray examinations, which if these are followed, compliance with dose and image quality criteria as specified in the document should be demonstrated. Studies in some countries have shown that a number of X-ray departments are not using optimum techniques. This study aimed at examining level of adherence of some selected hospitals in Nigeria to the CEC. Four hospitals were considered in the study, three of which are University Teaching Hospitals and Public Hospital. The following details on techniques and equipment were recorded for chest, abdomen, pelvis, skull and lumber spine examinations of standard sized patients: tube potential (kvp), focus-to-film distance (FFD), automatic exposure control (AEC), film-screen combination. From the study, varying level of adherence to were evident, with no hospitals demonstrating 1% compliance. 1. INTRODUCTION The radiation protections of patient undergoing medical X-ray examinations is governed by principle of justification and optimisation. It is concerned with the control of the manner in which sources of ionizing radiation are used so that in the use of the sources, members of the public are not irradiated above acceptable levels [1]. Hence, good radiographic technique is necessary to reduce level of exposure and risks from diagnostic procedure. In order to achieve appropriate radiographic techniques the Commission of European Communities issued the European Guidelines on Quality Criteria for Diagnostic Radiographic Images, a publication which includes examples of good radiographic techniques for a number of common X-ray examinations; that if adhered to, should demonstrate good compliance with image and dose criteria [2]. In Nigeria, to promote the optimization principles, it is necessary for X-ray Departments to examine their work practices, assess the level of adherence to CEC, identify areas where less than optimal techniques exist, and implement recommendations. Studies in Ireland, England, Germany, Greece and Sudan have shown that a number of X-ray Departments are not using optimum techniques [3],[4],[5],[6]. In the present study the radiographic techniques employed in six X-ray departments of four public hospitals in Nigeria were examined. Variations in techniques were recorded and compliance with CEC were examined. 2. MATERIALS AND METHOD The study was conducted in four public hospitals in southern part of Nigeria. They are Ladoke Akintola University of Technology Teaching Hospital (LAUTECHTH) Osogbo, Obafemi Awolowo University Teaching Hospital Complex (OAUTHC), Wesley Guild Ilesa, University of Benin Teaching Hospital (UBTH), Benin City and Central Hospital, Benin-City. A total of five hundred and eighty (5) patients comprising 319 males and 261 females referred to X-ray departments between September 8 and May 9 were investigated. For each patient and X-ray Unit, the following parameters were recorded: sex, age, weight, Focus-to-Film Distance (FFD), anatomical area examined, film-screen combination, tube potential (kvp), and product of tube current and time (mas). Four routine types of (7 projections) of X-ray examinations were studied, they are: Posterior-Anterior (PA) Chest, Anterior-Posterior (AP) Abdomen, AP/PA Skull, Lateral Skull, AP Pelvis/Hip, AP Lumbar Spine, LAT Lumber Spine. Six X-ray machines from six X-ray rooms were considered: they included a 3-phase Siemens machine (at OAUTHC Ilesa), a 3-phase Phillips machine and 3-phase Neo diagnomas (at LAUTECH, Osogbo), a 3-phase Toshiba machine and a 3-phase Watson Stylos machine (at UBTH Benin-City) and a 3-phase Siemens machine (at Central Hospital, Benin-City). 139

IJRRAS 9 (1) October 11 All six X-ray rooms in the four hospitals were equipped with the three-phase X-ray machines using equivalent total filtration of 2.5mmAl. Quality Assurance (QA) tests were performed on each X-ray machine to determine the linearity and reproducibility of X-ray tube output. The tests performed showed that the kvp were within the acceptable limit of 1%. 3. RESULTS The comparison for techniques employed in the four Nigerian hospitals with CEC Guidelines is shown in Table 1 below No hospital exhibited 1% compliance with CEC. Cases were observed in one hospital where FFD as low as 9cm was used for chest PA examination and also an FFD as low as cm was used for abdomen examinations. Table 1: Comparison of Techniques Employed with Commission of European Communities (CEC) Examination Total no. of Departments FFD Use of AEC Nominal Film Screen System Speed No. of No. of No. of Department Department CEC CEC Departments s not CEC s not Guideline in Guidelin not achieving achieving Guideline achieving (cm) e CEC CEC CEC Chest PA 6 1(1-) 2 Yes 6 6 Skull AP/PA 6 115(1-15) 2 Yes 6 6 Skull LAT 6 115(1-15) 2 Yes 6 6 Abdomen 6 115(1-15) 1 Yes 6 6 Pelvis/Hip 6 115(1-15) 1 Yes 6 6 AP Lumber Spine 6 115(1-15) 1 Yes 6 6 AP Lumber Spine LAT 6 115(1-15) 2 Yes 6 6 The figure in parenthesis indicate the minimum and maximum acceptable FFD distances. Key: FFD - Focus-to-Film Distance AEC - Automatic Exposure Control AP - Anterior-Posterior LAT - Lateral All the four hospitals used a nominal film-screen speed of for all examinations. These speeds were less than those suggested by the CEC. Examination of the Mean Tube Potential chosen demonstrated inadequate levels for some projections. All departments employed values lower than 125kVp recommended in the CEC for Chest examination. They employed lower tube voltages within the range of 52kVp to 94kVp. For Pelvis/Hip examination, one hospital used tube potential of 1kVp which is higher than the value recommended in CEC Guidelines. Also for Lumber Spine AP, Lumber Spine LAT and Abdomen, five departments employed Tube Potentials within the range recommended in CEC Guidelines but one of the departments used tube potentials of 13kVp, 17kVp and 12kVp respectively, which are much higher than the recommended values. The Tube Potential (kvp) selected for each projection across all departments compared with the Commission of European Communities Recommendations is shown in figures 1-7. 1

kvp SELECTED IJRRAS 9 (1) October 11 Fig. 1: 13 1 11 1 9 7 5 3 1 66 73 CHEST PA 52 73 Tube Potential (kvp) selected for Posterior-Anterior (PA) Chest Projection across all departments compared with the Commission of European Communities Recommendations in dotted lines. 85 94 1 PELVIS/HIP AP 1 9 85 87 7 5 3 1 73 76 76 I II III IV V IV Fig. 2: Tube Potential (kvp) selected for Anterior-Posterior (AP) Pelvis/Hip Projection across all departments compared with the Commission of European Communities Recommendations in dotted lines. 141

kvp SELECTED IJRRAS 9 (1) October 11 SKULL AP/PA 9 7 69 79 9 87 5 3 1 Fig. 3: Tube Potential (kvp) selected for Anterior-Posterior/Posterior-Anterior (AP/PA) Skull Projection across all departments compared with the Commission of European Communities Recommendations in dotted lines. SKULL LAT 9 7 72 64 78 83 83 5 3 1 Fig. 4: Tube Potential (kvp) selected for Lateral (LAT) Skull Projection across all departments compared with the Commission of European Communities Recommendations in dotted lines. 142

kvp SELECTED IJRRAS 9 (1) October 11 1 LUMBER SPINE AP 1 9 79 86 91 13 Fig. 5: Tube Potential (kvp) selected for Anterior-Posterior (AP) Lumber Spine Projection across all departments compared with the Commission of European Communities Recommendations in dotted lines. 1 LUMBER SPINE LAT 17 1 9 92 88 91 76 Fig. 6: Tube Potential (kvp) selected for Lateral (LAT) Lumber Spine Projection across all departments compared with the Commission of European Communities Recommendations in dotted lines. 143

IJRRAS 9 (1) October 11 ABDOMEN 1 13 1 7 81 83 71 Fig. 7: Tube Potential (kvp) selected for Abdomen Projection across all departments compared with the Commission of European Communities Recommendations in dotted lines. 4. DISCUSSION OF RESULTS The European and other international organizations are emphasizing the importance of appropriate Quality Assurance (QA) programme in diagnostics radiology in order to optimize the dose given to patients during X-ray diagnostics examinations. The Commission of European Communities described examples of good radiographic technique in its publication. Although, this publication is not intended to be a definitive set of instructions, are provided which, if adhered to should promote the optimization principle of producing images of good diagnostic efficacy at the lowest radiation dose. Previous studies have shown that adherence to CEC Guidelines have led to reductions in effective dose by up to 5% with no change in image quality. In this study, examination of the techniques employed, namely FFD, tube potentials (kvp), AEC usage and choice of film screen speed combination in the departments under consideration showed varying levels of compliance with the CEC. In the use of optimum FFD, all the departments showed varying levels of compliance with one department using FFD as low as 9cm for chest radiography and another department employed an FFD of cm which is lower than minimum level described in CEC Guidelines. The use of optimum FFD is considered very important, since a direct relationship between shorter FFD, higher patient s dose and decreased in geometric unsharpness is well established [7], [8]. The Tube Potentials (kvp) employed by the departments under consideration were inconsistent with the CEC Guidelines. All the departments employed tube potential below 125 kvp recommended in CEC Guidelines for Chest examination. Also one of the departments employed a high tube potential ( 1kVp) for Lumber Spine AP, Lumber Spine LAT and Abdomen respectively. The optimal tube potential in Chest radiography has received a considerable amount of discussion in the radiological literature [9], [1]. It has been shown that increasing the tube potential in Chest radiography from kvp to 9kVp will result in an Entrance Surface Dose (ESD) saving of % [11]. Also the use of high voltage technique for the Chest has been calculated to reduce effective dose equivalent by % [11], [12]. Therefore, the use of low tube potentials should be discouraged. In this survey, all the departments used nominal film-screen combination, this may be longest contributing factor for the higher ESD recorded in some departments since reduction in ESD with increasing speed of image receptor has been demonstrated in the UK [13], [1]. In the UK, the percentage of rooms with a mean speed greater than rose from 23% for the 1986 NRPB survey [11] to nearly % for the 1996 UK Survey [13]. The change to a faster film-screen combination was probably the main factor in reducing the ESD by 3%-%. It is worthy to note that none of the departments in the study complied with CEC Guideline in AEC usage as all departments employed manual selection of the exposures. These may be due to equipment limitations. The mean entrance surface dose for all the examination have been calculated using the recorded exposure factors. It was observed that dose values were within the recommended guidance level except in one hospital where a higher dose value of.4mgy was recorded for Chest AP, which is higher than the recommended value. 144

IJRRAS 9 (1) October 11 5. CONCLUSION AND RECOMMENDATION In this study, varying levels of compliance with the CEC Guidelines on good radiographic technique were observed in all departments for Chest PA, Skull AP/PA, Skull LAT, Abdomen, Pelvis/Hip AP, Lumber Spine AP and Lumber LAT. All departments demonstrated non-adherence for at least one CEC recommendation, with no hospital demonstrating 1% non-compliance. Complete compliance to CEC Guidelines should be aimed at by all the departments for dose-reduction, particularly by paying close attentions to choice of FFDs optimum tube potentials and total filtration. These would facilitate lower radiation dose without affecting image quality. 6. ACKNOWLEDGEMENT The authors would like to thank the hospitals used in this study and their staff for their assistance and cooperation during the study. 7. REFERENCES [1]. ICRP (1996) : Radiological Protection and Safety in Medicine (ICRP Publication 73) Ann. ICRP 26 (Oxford Pergamon). [2]. CEC (1996): Commission of European Communities: European Guidelines on Quality Criteria for Diagnostic Radiographic Images. EUR162EN. Brussels, Belgium. [3]. Brennan P.C. and Johnson D.A. (2): Reference Dose Levels for Patients Undergoing Common Diagnostic X-ray Examination in Irish Hospitals. Br. J. Radio. 73:396-2, Pontish Journal of Radiology. [4]. Saure D., Hagemann G. and Stender H.S. (1995): Image Quality and Patient Dose in Diagnostic Radiology. Radiat Prot Dosim 57: 445-8 (Abstract) [5]. McNeil E.A. Peach D.E. and Temperton D.H. (1995): Comprism of Entrance Surface Doses and Radiographic Techniques in the West Midlands (UK) with The CEC Criteria Specifically for Lateral Lumbar Spine Radiographs. Radiat Prot Dosim 57: 437- (Abstract) [6]. Suliman I.I., Abbas N. and Habbani F.I. (6): Entrance Surface Doses to Patients Undergoing Selected Diagnostic X-ray Examinations in Sudan: Radiat Prot. Dosim 123:2, 9-214. [7]. Vano E., Oliete S., Gonzalez L. Guibelade E., Velasco A. and Fernandez J.M. (1995): Image Quality and Dose in Lumber Spine Examinations: Result of a 5 year Quality Control Programme following the European Quality Criteria Trial Br. J. Radiol 68:1332-5. [8]. Brennan P.C. and Nash M. (1998): Increasing FFD: An Effective Dose-Reducing Tool for Lateral Lumber Spine Investigation. Radiography, 1998, 4:251-9. [9]. Buttler P.F., Conway B.J., Suleiman O.H., Koustenis G.H. and Showalter C.K. (1985): Chest Radiography: A Survey of Techniques and Exposure Levels Currently Used. Radiology 156, 533-6. [1]. Warren-Forward H.M. and Millar J.S. (1995): Optimization of Radiographic Technique for Chest Radiography. Br. J. Radiol; 156:1221-9. [11]. Shrimpton P.C., Wall B.F. Jone D.G. Fisher E.S., Hillier M.C. and Kendal G. M. (1986): A National Survey of Doses to Patients Undergoing a Selection of Routine X-ray Exposures in English Hospitals NRPB R London. BMSO. [12]. Martin C.J., Darragh C.L., McKenzie G.A., and Bayliss A.P. (1993): Implementation of a Programme for Reduction of Radiographic Doses and Results through Increase in Tube Potential. Br. J. Radiol. 66:228-33. Pontish journal of Radiology. [13]. Hart D., Hitler M.C., Wall B.F., Shrimpton P.C. and Bungay D. (1996): Doses to Patients from Medical X- ray Examinations in the UK- 1995 Review, NRPB 289. London HMSO. 145