SAMPLE. Glucose Monitoring in Settings Without Laboratory Support

Similar documents
SAMPLE. Clinical and Laboratory Standards Institute Advancing Quality in Health Care Testing

SAMPLE I/LA20. 3rd Edition

(Formerly NCCLS) Providing NCCLS standards and guidelines, ISO/TC 212 standards, and ISO/TC 76 standards

C30-A2 ISBN ISSN Point-of-Care Blood Glucose Testing in Acute and Chronic Care Facilities; Approved Guideline Second Edition

Using Blood Glucose Meters in the Hospital: Defining Critically Ill and Addressing Accreditation Issues

It s Just a Waived Glucose, Isn t It?

Compliance Issues in Off-Label Use of Blood Glucose Monitors

SAMPLE. Control of Preanalytical Variation in Trace Element Determinations; Approved Guideline

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

Bern Harrison, B.A., Cheryl Leazenby, B.S., and Solveig Halldorsdottir, Ph.D.

Quick Reference Guide

Quick Reference Guide

Management of Central Venous Access Devices. Blood Glucose Monitoring

System accuracy evaluation of FORA Test N Go Blood Glucose Monitoring System versus YSI 2300 STAT Plus glucose analyzer following ISO 15197:2013

Quick Reference Guide

SAMPLE. Design and Validation of Immunoassays for Assessment of Human Allergenicity of New Biotherapeutic Drugs; Approved Guideline

Multi User Model. Product Overview

Equivalent Accuracy Evaluation of FORA Premium V10 Blood Glucose Monitoring System as Compared to Fora V30 Blood Glucose Monitoring System

Blood Glucose Measurement. Omnitest 5 & Omnican Lance FAQ Frequently Asked Questions

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

8. Quality Assurance Guidelines (Includes Appendices A-G)

GB/T Translated English of Chinese Standard: GB/T

User s Manual Blood Glucose Meter

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

Point of Care Testing for INR using CoaguChek XS Plus

Precision Xtra Training

Dear HighQ Check System Owner :

HOME HEALTH FOUNDATION CLINICAL TEAM COMPETENCY Clinical Bag Technique. EMPLOYEE STAFF POSITION Date

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

SAMPLE. Laboratory Detection and Identification of Mycobacteria; Approved Guideline

Blood Glucose Monitoring System

Point of Care (POC) Glucose Testing Revised on: December, 2018 Reference: Policy LAB 23-A; Point of Care Nova Stat Strip Glucose Meter

Blood Glucose Monitoring System. User s Manual for Single Patient Use Only Blood Glucose Meter

Summary of Significant Changes at this Revision. Items Required

ISO IVD 13485: : :2015

System accuracy evaluation of FORA Test N Go Blood Glucose Monitoring System versus YSI 2300 STAT Plus glucose analyzer following ISO 15197:2013

Blood Glucose Monitoring System. User Guide

Important Safety Information. Intended Use WARNING. The Contour Next EZ blood glucose monitoring system is

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY ONLY TEMPLATE

User s Manual Blood Glucose Meter

Items in the package:

Point of Care Testing. Bedside Glucose Meter

User Manual second language

Aviva Combo. Aviva Combo. Standard Owner s Booklet for Self-Testing Only BLOOD GLUCOSE METER

Dear Prodigy System Owner:

GlucoCheck BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

BLOOD GLUCOSE MONITORING: CLINICAL NEED AND TECHNOLOGY

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

ANSI/ASNT CP-189 Inquiries

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

Relationship between glucose meter error and glycemic control efficacy

Blood Glucose Monitoring System. Owner s Booklet

PLUS One. Blood Glucose Monitoring System. Owner s Manual

METHOD VALIDATION: WHY, HOW AND WHEN?

Evaluation of Accuracy and User Performance of the TRUE METRIX Blood Glucose Monitoring System

Survey results - Analysis of higher tier studies submitted without testing proposals

Individual Quality Control Plans (IQCP) Risk Assessment

White Paper, Evaluation of WaveSense JAZZ Blood Glucose Monitoring System Analytical Performance to EN ISO 15197:2015 Standard

Control D. User Manual. Blood Glucose Monitor. Subscribe on MYCONTROL.life HAIDEN

Blood Glucose & Ketone Monitoring System

Title: Abbott Optium Xceed Glucose Meter Effective date: 16/05/2011. Summary of Significant Changes at this Revision. SOP updated.

INTRODUCTION: TRUE METRIX

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

SAMPLE. Reference and Selected Procedures for the Quantitative Determination of Hemoglobin in Blood; Approved Standard Third Edition

VOICE. Blood Glucose Monitoring System. Owner s Manual

Blood Glucose Monitoring System

Patient Safety: A Quality System Approach To POCT QC/QA

GlucoMen LX PLUS blood glucose and blood ketone meter. Accuracy Evaluation to New ISO 15197:2013, with Technical and Specification Data

Point of Care testing refers to all laboratory testing that is done outside of the walls of the clinical laboratory in the proximity of the patient.

DIABETES BLOOD GLUCOSE MONITORING AT HOME (ADULTS)

PRIMA. Blood Glucose Monitoring System. Owner s Manual

User Manual. For single user / home use only

User Manual. For single user / home use only

NJ RAPID HIV TESTING SUPPORT PROGRAM

Blood Glucose Monitoring System

Prodigy Talking Meter Owner s Manual. Dear Prodigy Owner:

Virginia Beach Department of Emergency Medical Services. CAAS # Index # Administration VACCINATION POLICY

Urgent Field Safety Notice

Blood Glucose and ß -Ketone Monitoring System. Owner s Manual

TITLE: Whole Blood Glucose Monitoring Using the Nova StatStrip Meter

EVENCARE G3 BLOOD GLUCOSE MONITORING SYSTEM USER S GUIDE

Your pet s diabetes is manageable

IMPORTANT SAFETY INFORMATION

Summary of Significant Changes at this Revision

DIABETES BLOOD GLUCOSE MONITORING AT HOME (ADULTS)

ISO INTERNATIONAL STANDARD

CHAPTER NINE INSULIN AND GLUCAGON ADMINISTRATION

Evaluation of Accuracy and User Performance of the TRUE METRIX Self-Monitoring Blood Glucose System

Quality Control for Point-of-Care Testing

The performance of Microdot Test Strips has been evaluated both in laboratory and in clinical tests.

Alere INRatio 2 METHOD AND SAMPLE COLLECTION

Clinical Accuracy and User Performance of the TRUE METRIX AIR Blood Glucose Monitoring System

INTRODUCTION: McKesson TRUE METRIX Self Monitoring Blood Glucose System

NEPHROCHECK Calibration Verification Kit Package Insert

SAMPLE. Protection of Laboratory Workers From Occupationally Acquired Infections; Approved Guideline Fourth Edition

Aviva Combo BLOOD GLUCOSE METER. Advanced Owner s Booklet for Self-Testing Only

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Precision ceedpro. Online Training for. Glucometer & Capillary Collection

Colgate University. Bloodborne Pathogens Exposure Control Plan

Transcription:

POCT13c Glucose Monitoring in Settings Without Laboratory Support This guideline focuses on performance of point-of-care glucose monitoring systems, with an emphasis on safety practices, quality control, training, and administrative responsibility. 3rd Edition A guideline for global application developed through the Clinical and Laboratory Standards Institute consensus process.

The Clinical and Laboratory Standards Institute consensus process, which is the mechanism for moving a document through two or more levels of review by the health care community, is an ongoing process. Users should expect revised editions of any given document. Because rapid changes in technology may affect the procedures, methods, and protocols in a standard or guideline, users should replace outdated editions with the current editions of CLSI documents. Current editions are listed in the CLSI catalog and posted on our website at www.clsi.org. If you or your organization is not a member and would like to become one, and to request a copy of the catalog, contact us at: P: 610.688.0100 F: 610.688.0700 E: customerservice@clsi.org W: www.clsi.org. POCT13c, 3rd ed. June 2018 Replaces POCT13-A2 and POCT13, 3rd ed. Glucose Monitoring in Settings Without Laboratory Support James R. Petisce, PhD Pamela Allweiss, MD Randy Byrd William L. Clarke, MD Karen W. Dyer, MT(ASCP), DLM Lynette Hall Bern Harrison Mark Hudgins Ellis Jacobs, PhD Mary M. Kimberly, PhD George Koumantakis, PhD Abstract Leslie Landree John J. Mahoney Peggy Mann, MS, MT(ASCP) Ronald H. Ng, PhD, DABCC, FACB Gene M. Pagnani Melissa K. Schaefer, MD Mitchell G. Scott, PhD Suzanne Snozyk, MLT, ART Halcyon St. Hill, EdD, MS, MT(ASCP) Nimalie Stone, MD, MS Clinical and Laboratory Standards Institute document POCT13 Glucose Monitoring in Settings Without Laboratory Support was developed for personnel monitoring glucose levels at sites other than a hospital laboratory. In a question and answer format, the document provides recommendations related to administrative structure, operator authorization, test system selection, QA, and test procedure. Samples of a written evaluation and QC logs are also included. Clinical and Laboratory Standards Institute (CLSI). Glucose Monitoring in Settings Without Laboratory Support. 3rd ed. CLSI guideline POCT13c (ISBN 978-1-68440-000-3 [Print]; 978-1-68440-001-0 [Electronic]). Clinical and Laboratory Standards Institute, 950 West Valley Road, Suite 2500, Wayne, Pennsylvania 19087 USA, 2018.

Copyright 2018 Clinical and Laboratory Standards Institute. Except as stated below, any reproduction of content from a CLSI copyrighted standard, guideline, derivative product, or other material requires express written consent from CLSI. All rights reserved. Interested parties may send permission requests to permissions@clsi.org. CLSI hereby grants permission to each individual member or purchaser to make a single reproduction of this publication for use in its laboratory procedures manual at a single site. To request permission to use this publication in any other manner, e-mail permissions@clsi.org. Suggested Citation* CLSI. Glucose Monitoring in Settings Without Laboratory Support. 3rd ed. CLSI guideline POCT13c. Wayne, PA: Clinical and Laboratory Standards Institute; 2018. Previous Editions: December 1996, June 1999, May 2005, June 2015 ISBN 978-1-68440-000-3 (Print) ISBN 978-1-68440-001-0 (Electronic) ISSN 1558-6502 (Print) ISSN 2162-2914 (Electronic) Volume 38, Number 11 * POCT13 was corrected in June 2018, and the code was revised to POCT13c. ii

Contents Abstract i Committee Membership Foreword Chapter 1: Introduction 1 1.1 Scope...2 1.2 Background...4 1.3 Standard Precautions...5 1.4 Terminology...5 Chapter 2: Infection Control Program 11 Chapter 3: Information for the Coordinator 15 3.1 Why Is a Coordinator Needed?...16 3.2 What Are the Responsibilities of a Coordinator?...16 3.3 Training Program for Operators...17 3.4 How Should the Competence of Operators Be Determined?...20 Chapter 4: What Considerations Should Guide the Choice of a Glucose Monitoring System? 23 4.1 Glucose Meter Performance...24 4.2 Intended Use...24 4.3 Reagents...25 4.4 Manufacturer Support...25 4.5 Testing...25 4.6 Maintenance and Service...26 Chapter 5: What Should the Coordinator Do to Start a Glucose Monitoring Program? 27 5.1 Important Safety Measures...28 5.2 What Is Needed to Perform Glucose Monitoring?...29 5.3 What Should Be Done Before Testing?...30 5.4 What Should Be Included in Recording Test Results?...31 5.5 What Are Appropriate Responses to Abnormal Blood Glucose Concentrations?...31 5.6 Why Is a Procedure Manual Needed and What Should it Contain?...31 5.7 What Are the Components of a Quality Assurance Program?...33 5.8 Information for the Operator...36 iii vii v

Contents (Continued) Chapter 6: Documentation of Quality Control Results and Meter Maintenance 39 Chapter 7: Proficiency Testing 41 Chapter 8: Conclusion.................................................................................. 43 Chapter 9: Supplemental Information 45 References...46 Appendix A. Quality Assurance: Meter Maintenance Log...48 Appendix B. Example of a Procedure Format...49 Appendix C. Blood Glucose Test Result Log (Units of Measure)...50 Appendix D. Example of a Potential Quality Assurance Record: Quality Control Log...51 Appendix E. Common Problems With the Use of Glucose Meters.............................................. 52 The Quality Management System Approach...56 Related CLSI Reference Materials...58 vi

Foreword This document contains guidelines for performance of point-of-care glucose monitoring systems that emphasize safety practices, QC, training, and administrative responsibility. This guideline was developed for personnel monitoring glucose levels at sites other than a hospital laboratory. Additionally, personnel must only perform tests that have been authorized by the site coordinator and must meet the personnel qualifications involved in performing point-of-care testing. In a question and answer format, the document provides recommendations related to administrative structure, operator authorization, test system selection, QA, and test procedure. Samples of a written evaluation and QC logs are also included. Overview of Changes This document replaces the second edition of the guideline, POCT13-A2, which was published in 2005. Several changes were made in this edition; chief among them include: Safety recommendations in Chapter 2 Training program recommendations in Subchapter 3.3 Information related to alternate site testing in Subchapter 5.3.2 Information related to glucose meter result variations in Subchapter 5.7.3 This document was corrected in 2018 and replaces the original third edition of the guideline, POCT13, 3rd ed., which was published in June 2015. Corrections were made as follows: In Subchapter 1.4.2, the definition of lancing device was expanded for clarification. In Chapter 2, recommendations regarding the use of lancing devices, lancets, and glucose meters to prevent transmission of bloodborne pathogens were strengthened. Recommendations regarding the use of devices for dispensing insulin were added. In Chapter 3, the glucose monitoring program coordinator s responsibilities for infection control were clarified, including training and oversight practices. In Chapter 4, the intended use of blood glucose meters (ie, individual vs multipatient use meters) was clarified. In Chapter 5, the safety recommendations to prevent the transmission of bloodborne pathogens were improved. important note: Personnel must only perform tests that have been authorized by the site coordinator and must meet the personnel qualifications involved in performing pointof-care testing. important note: Throughout POCT13, the use of the term must was evaluated by the document development committee and deemed appropriate because the uses are either 1) based on a requirement or 2) indicative of a necessary step to ensure patient safety or proper fulfillment of a procedure. vii

key words Authorization Blood glucose Coordinator Diabetes NOTE: Mandates are occasionally allowed in CLSI guidelines, in cases in which the document development committee feels strongly that a particular action is either required or prohibited, or when a guideline addresses provisions based on regulations. Throughout POCT13, the use of the term must was evaluated by the document development committee and deemed appropriate because the uses are either 1) based on a requirement or 2) indicative of a necessary step to ensure patient safety or proper fulfillment of a procedure. Glucose monitoring system Meter Operator Quality assurance Quality control Training viii

Chapter 1 Introduction This chapter includes: Document scope and applicable exclusions Background information pertinent to the document content Standard precautions information Note on Terminology that highlights particular use and/or variation in use of terms and/or definitions Terms and definitions used in the document Abbreviations and acronyms used in the document

Glucose Monitoring in Settings Without Laboratory Support note: It is assumed that authorized personnel have met the minimum personnel qualifications and training specified by the site coordinator. note: This guideline should be used in settings where there is no laboratory support, to be defined by each institution. All areas of use shall be staffed with personnel who are authorized by the institution to use BGMS. reminder: Operators monitoring glucose levels in acute and chronic care facilities with on-site laboratory support should refer to CLSI document POCT12. 1 1 Introduction 1.1 Scope 1.1.1 Who Should Use This Guideline? This guideline was developed for authorized personnel directly involved in the establishment, management, and implementation of a blood glucose (BG) monitoring (BGM) program at sites without support from hospital laboratories. For the purposes of this document, these authorized personnel are referred to as operators. In settings where there is more than one operator, one individual should be designated to coordinate the testing program. For the purposes of this document, this individual is referred to as the coordinator. It is assumed that authorized personnel have met the minimum personnel qualifications and training specified by the site coordinator. 1.1.2 Where Should This Guideline Be Used? This guideline should be used in settings where there is no laboratory support, such as those listed below, to be defined by each institution. All areas of use shall be staffed with personnel who are authorized by the institution to use BGM systems (BGMS). This guideline is not intended for use in acute and chronic care facilities with on-site laboratory support. Operators monitoring glucose levels in these types of settings should refer to CLSI document POCT12. 1 This guideline may be used in a variety of locations, which include but are not limited to: Physicians offices Camps attended by people with diabetes Mobile emergency medical facilities Free-standing dialysis facilities Home health care settings (not applicable to individuals with diabetes who do their own testing) Visiting nursing programs or home care agencies Public health facilities Mobile or free-standing clinics (eg, migrant worker clinics, other clinics in remote locations) Occupational health facilities Pharmacies Prisons 2 Clinical and Laboratory Standards Institute. All rights reserved.

reminder: 14 What Considerations Should Guide the Choice of a Glucose Monitoring System? Individuals responsible for sourcing and considering 4.1 Glucose Meter Performance a BGM device may also check publications in peerreviewed journals on system include trueness, precision, and diagnostic accuracy of the system, The performance characteristics of different BGMS available, which performance evaluations in within the critical BG ranges (eg, < 70 mg/dl [< 3.8 mmol/l], 70 to accordance with ISO 15197, 12 if 180 mg/dl [3.8 to 10 mmol/l], > 180mg/dL [> 10 mmol/l]) applicable. For information on device performance, see the product labeling. Individuals responsible for sourcing and considering a BGM device may also check publications in peer-reviewed journals on system performance evaluations in accordance with ISO 15197, note: 12 if applicable. Consider possible interferences Impact and number of interferences, assessed by the manufacturer when choosing a glucose (including medications, abnormal hematocrits, etc.), on the test monitoring system. For system example, the commonly For example, the commonly consumed medication consumed medication acetaminophen is a possible exogeneous interfering substance, acetaminophen is a possible which has caused falsely high glucose readings with some exogeneous interfering glucose meters. substance, which has caused Whether or not the manufacturer has relevant open compliance falsely high glucose readings issues as cited by regulatory agencies (eg, US Food and Drug with some glucose meters. Administration in the United States) 4.2 Intended Use note: Individual vs multipatient use meters: If a meter is to be used on more than one person, the meter must be specifically designated When the patient population by the manufacturer as appropriate for multipatient use, 25 and the needs the option of alternate manufacturer s instructions for cleaning and disinfection after each site testing, ensure that the use must be followed. BGMS instructions for use, Range of BG concentrations measured by the system, compared to from the manufacturer, ranges likely in the patient population specifically state that it is intended for that use. If the patient population needs the option of alternate site testing, ensuring that the BGMS is intended for that use Types of built-in fail-safes the system offers to prevent erroneous readings from being produced or recognized Other limitations for use 24 Clinical and Laboratory Standards Institute. All rights reserved.

Appendix E. Common Problems With the Use of Glucose Meters Causes of unreliable results may be individual/sample based or user/device based. Whenever a blood glucose test result is different than expected, ie, different from the person s clinical presentation, the test should be repeated with a fresh blood sample. If the result obtained remains different than expected, a QC solution measurement should be taken and compared to the acceptable range. If the QC solution value is unacceptable, the result should not be acted upon and the point-of-care glucose monitoring system instructions for use should be consulted for the manufacturer s recommended troubleshooting actions. Some common problems and their effects on meter glucose readings are listed in Table E1. Table E1. Common Problems With Glucose Meters and Recommended Actions Problem Results Recommendation Glucose test strips not fully inserted into meter Unreliable result or error code, or meter will not activate Always be sure glucose test strip is fully inserted in meter. Glucose test strip inserted upside down or wrong end inserted Unreliable result or error code, or meter will not activate Read instructions to learn correct insertion technique. Display read upside down Erroneous result (eg, 252 can read as Review meter use instructions. 525) Incorrectly coded meter Unreliable result Always confirm that the correct code has been entered. Sample site contaminated with sugar (eg, the fingertip) Unreliable result Always thoroughly clean and dry test site before sampling. Not enough blood applied to glucose test strip Unreliable result or error code Visually observe glucose test strip when filling to ensure proper filling. User adds additional sample during reaction Unreliable result Review instructions for proper use techniques. Batteries low on power Error code Change batteries and repeat sample collection. Glucose test strips/controls past expiration date Unreliable result Check expiration dates and use within date supplied. Glucose test strips/controls stored at temperature or humidity extremes Unreliable result Store kit and use strips according to manufacturer s directions. Person dehydrated Unreliable result Call for additional assistance. Person in shock Unreliable result Call for additional assistance. Sites other than fingertips used Unreliable result Results from alternate sites may not match fingerstick results (physiological lag). Use fingerstick blood for POCT. Presence of interfering medications or substances Unreliable result Check product insert for list of interfering substances, including disinfectant(s) not recommended by the manufacturer. 52 Clinical and Laboratory Standards Institute. All rights reserved.