Non-invasive diagnosis of hepatitis B virus-related cirrhosis

Similar documents
Non-Invasive Testing for Liver Fibrosis

PROPOSTA DI UN NUOVO ALGORIMO PER LA DIAGNOSI ECOGRAFICA DELLE MALATTIE CRONICHE DEL FEGATO

Transient elastography the state of the art

The role of non-invasivemethods in evaluating liver fibrosis of patients with non-alcoholic steatohepatitis

Noninvasive Diagnosis and Staging of Liver Disease. Naveen Gara, MD

Evaluation of liver and spleen stiffness using a ultrasound guided method: Accuracy of ARFI(R) measurements in liver disease patients

Transient elastography in chronic viral liver diseases

MR Elastography of Liver

iu22 Liver Shear Wave ElastPQ

The role of ARFI and APRI in diagnosis of liver fibrosis on patients with common chronic liver diseases

Medical Review Approaches to the Diagnosis of Liver Fibrosis

NONINVASIVE IMAGING METHODS FOR ASSESSMENT OF LIVER DAMAGE IN NASH

Evaluation of liver and spleen stiffness using a ultrasound guided method: Accuracy of ARFI(R) measurements in liver disease patients

Noninvasive Techniques for the Evaluation and Monitoring of Patients With Chronic Liver Disease

Noninvasive Techniques for the Evaluation and Monitoring of Patients With Chronic Liver Disease

In Search of New Biomarkers for Nonalcoholic Fatty Liver Disease

Invasive. Sampling error. Interobserver variability. Nondynamic evaluation of

Non-Invasive Assessment of Liver Fibrosis. Patricia Slev, PhD University of Utah Department of Pathology

Module 1 Introduction of hepatitis

Research Elastography: Liver

New Tools for Assessing Disease Sererity, progression and regression in HBV and HCV

Ultrasound Committee Activities

NONINVASIVE TECHNIQUES FOR EVALUATION AND MONITORING OF CHRONIC LIVER DISEASE

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Improved Hepatic Fibrosis Grading Using Point Shear Wave Elastography and Machine Learning

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Elastography in the. technically difficult patient. EPIQ ultrasound system. Ultrasound

MP Noninvasive Techniques for the Evaluation and Monitoring of Patients With Chronic Liver Disease

DISCLOSURES. This activity is jointly provided by Northwest Portland Area Indian Health Board and Cardea

shear wave elastography

Transient elastography in chronic liver diseases of other etiologies

Liver elastography ultrasound cpt code

Medical technologies guidance Published: 23 September 2015 nice.org.uk/guidance/mtg27

NON INVASIVE EVALUATION OF DISEASE PROGRESSION IN CHRONIC LIVER DISEASES

HEP DART 2017, Kona, Hawaii

Cirrhosis and Portal Hypertension Gastroenterology Teaching Project American Gastroenterological Association

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

Ultrasound elastography in abdominal imaging

5/2/2016. Arthur Y. Kim, MD Assistant Professor of Medicine Harvard Medical School Massachusetts General Hospital Boston, Massachusetts

Hepatic Imaging: What Every Practitioner Should Know

Management of Liver Diseases: A Nonhepatologist s Viewpoint

Learning Objectives. After attending this presentation, participants will be able to:

Assessment of Liver Stiffness by Transient Elastography in Diabetics with Fatty Liver A Single Center Cross Sectional observational Study

Faculty Disclosure. Objectives. Cirrhosis Management for the Family Physician 18/11/2014

New York State HCV Provider Webinar Series

Byung Ihn Choi, M.D. Department of Radiology Seoul National University Hospital

NON INVASIVE ASSESSMENT OF LIVER FIBROSIS : FIBROSCAN

Ge elastography cpt codes

JPGN Journal of Pediatric Gastroenterology and Nutrition Publish Ahead of Print

*APHP: Hôpital Beaujon Professor P Bedossa, Dr F Degos, Professor P Marcellin, Professor

Initial Evaluation for HCV Therapy. Hope McGratty PA-C, MPH

Medical Policy Non-invasive Tests for Hepatic Fibrosis

When to Treat: Staging Liver Disease David L. Thomas, MD, MPH

INHSU th International Symposium on Hepatitis Care In Substance Users

Simplifying liver assessment in internal medicine

Pretreatment Evaluation

Liver Ultrasound - Beyond the Basics. Pamela Parker Lead Sonographer

Clinical Policy Title: Liver elastography

Pretreatment Evaluation

LOGIQ S8 XDclear 2.0 Liver Procedures

The Liver for the Nonhepatologist

UNIVERSA MEDICINA. Forns index as a useful noninvasive predictor of esophageal varices in liver cirrhosis

Real-time elastography as a noninvasive assessment of liver fibrosis in chronic hepatitis C Egyptian patients: a prospective study

Update on Non-Alcoholic Fatty Liver Disease. Timothy R. Morgan, MD Chief, Hepatology, VA Long Beach Professor of Medicine, UCI

Original papers Med Ultrason 2013, Vol. 15, no. 2, Ioan Sporea, Iulia Raţiu, Simona Bota, Roxana Şirli, Ana Jurchiş

Radiology Update 2017

Non-invasive assessment of liver fibrosis in chronic hepatitis B

Alice Fung, MD Oregon Health and Science University

Xiao-Ling Chi, Mei-Jie Shi, Huan-Ming Xiao, Yu-Bao Xie, and Gao-Shu Cai. Correspondence should be addressed to Xiao-Ling Chi;

Management of Hepatitis C in Primary Care BABAFEMI ONABANJO, MD & BEN ALFRED, FNP UMASS FAMILY HEALTH CENTER WORCESTER

National Horizon Scanning Centre. Enhanced Liver Fibrosis Test (ELF) for evaluating liver fibrosis. June 2008

Diagnostic TRUS Elastography of the Prostate

Comparative study between two point Shear Wave Elastographic. Acoustic Radiation Force Impulse (ARFI) elastography

CONFOUNDING FACTORS affecting the performance of US elastography

Surveillance for Hepatocellular Carcinoma

Hepatocytes produce. Proteins Clotting factors Hormones. Bile Flow

Prediction of Hepatocellular Carcinoma Incidence Risk by Ultrasound Elastography

NAFLD and NASH: The Not-So-New Kids on the Block

Liver 102: Injury and Healing

Evaluation of Liver Fibrosis using ShearWave Elastography on Aixplorer

In response to an enquiry from the Scottish Clinical Biochemistry Managed Diagnostic Network

Hepatology For The Nonhepatologist

Hepatology for the Nonhepatologist

DISCLOSURES. This activity is jointly provided by Northwest Portland Area Indian Health Board and Cardea

Laboratory Tests and Diagnostic Procedures in Liver Disease: Adventures in Liverland

Bio Predictive. FibroTest/FibroSure Scientific Publications. Houot 2015 FibroTest, TE, FIB-4, APRI Meta-analysis

The Future is Here Now!

CIRROSI E IPERTENSIONE PORTALE NELLA DONNA

Pretreatment Evaluation

LOGIQ E9 Shear Wave Elastography

The New World of HCV Therapy

ABNORMAL LIVER FUNCTION TESTS. Dr Uthayanan Chelvaratnam Hepatology Consultant North Bristol NHS Trust

Hepatitis C Policy Discussion

CHAPTER 1. Alcoholic Liver Disease

ULTRASOUND IN CHRONIC LIVER DISEASE

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

NASH : Diagnosis and investigation. VII Workshop international, Curitiba, Brazil 29/08/2014

The Liver for the Nonhepatologist

Transcription:

Online Submissions: http://www.wjgnet.com/esps/ bpgoffice@wjgnet.com doi:10.3748/wjg.v20.i2.445 World J Gastroenterol 2014 January 14; 20(2): 445-459 ISSN 1007-9327 (print) ISSN 2219-2840 (online) 2014 Baishideng Publishing Group Co., Limited. All rights reserved. TOPIC BRIEF HIGHLIGHT ARTICLE WJG 20 th Anniversary Special Issues (9): Hepatitis B virus Non-invasive diagnosis of hepatitis B virus-related cirrhosis Sangheun Lee, Do Young Kim Sangheun Lee, Do Young Kim, Department of Internal Medicine, Yonsei University College of Medicine, Seoul 120-752, South Korea Do Young Kim, Liver Cirrhosis Clinical Research Center, Seoul 120-752, South Korea Author contributions: Lee S and Kim DY contributed to this work; Kim DY designed research; Lee S and Kim DY performed research; and Lee S wrote the paper. Supported by a grant of the South Korea Healthcare technology R and D project, Ministry of Health and Welfare, South Korea, No. HI10C2020 Correspondence to: Do Young Kim, MD, Department of Internal Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 120-752, South Korea. dyk1025@yuhs.ac Telephone: +82-2-22281992 Fax: +82-2-3936884 Received: October 25, 2013 Revised: November 25, 2013 Accepted: December 5, 2013 Published online: January 14, 2014 Abstract Chronic hepatitis B (CHB) infection is a major public health problem associated with significant morbidity and mortality worldwide. Twenty-three percent of patients with CHB progress naturally to liver cirrhosis, which was earlier thought to be irreversible. However, it is now known that cirrhosis can in fact be reversed by treatment with oral anti-nucleotide drugs. Thus, early and accurate diagnosis of cirrhosis is important to allow an appropriate treatment strategy to be chosen and to predict the prognosis of patients with CHB. Liver biopsy is the reference standard for assessment of liver fibrosis. However, the method is invasive, and is associated with pain and complications that can be fatal. In addition, intra- and inter-observer variability compromises the accuracy of liver biopsy data. Only small tissue samples are obtained and fibrosis is heterogeneous in such samples. This confounds the two types of observer variability mentioned above. Such limitations have encouraged development of non-invasive methods for assessment of fibrosis. These include measurements of serum biomarkers of fibrosis; and assessment of liver stiffness via transient elastography, acoustic radiation force impulse imaging, real-time elastography, or magnetic resonance elastography. Although significant advances have been made, most work to date has addressed the diagnostic utility of these techniques in the context of cirrhosis caused by chronic hepatitis C infection. In the present review, we examine the advantages afforded by use of non-invasive methods to diagnose cirrhosis in patients with CHB infections and the utility of such methods in clinical practice. 2014 Baishideng Publishing Group Co., Limited. All rights reserved. Key words: Chronic liver disease; Chronic hepatitis B; Hepatitis B virus; Cirrhosis; Liver stiffness measurement; Transient elastography; Acoustic radiation force impulse imaging; Real-time elastography; Magnetic resonance elastography; FibroTest; Aspartate aminotransferase to platelet ratio index Core tip: Chronic hepatitis B (CHB) infection is associated with significant morbidity and mortality because it can progress to cirrhosis or hepatocellular carcinoma. Early diagnosis of liver cirrhosis in CHB patients is important to prevent the disease progression. Noninvasive diagnosis has been developed remarkably and showed high diagnostic accuracy for cirrhosis. New methods and the combination of non-invasive diagnosis tools may contribute to the improvement to diagnose the cirrhosis with CHB. Lee S, Kim DY. Non-invasive diagnosis of hepatitis B virusrelated cirrhosis. World J Gastroenterol 2014; 20(2): 445-459 Available from: URL: http://www.wjgnet.com/1007-9327/full/ v20/i2/445.htm DOI: http://dx.doi.org/10.3748/wjg.v20.i2.445 INTRODUCTION Serologically, hundreds of millions of people are chronic 445 January 14, 2014 Volume 20 Issue 2

hepatitis B (CHB) virus surface antigen (HBsAg) carriers and it is estimated that over 200000 CHB patients die worldwide each year from cirrhosis [1,2]. The prognosis is worse in those infected by hepatitis B virus (HBV) in areas in which the virus is endemic. The annual rate of progression from chronic hepatitis to cirrhosis is 2%-5% in HBV e antigen-positive and 3%-10% in e antigennegative patients [3]. Early diagnosis of liver cirrhosis in CHB patients is important because cirrhosis per se is an independent predictor of mortality. The 1-year mortality rates vary from 1% in patients with early-stage cirrhosis to 57% in those with decompensated disease [4-6]. In addition, the 5-year cumulative risk that a cirrhotic patient will develop hepatocellular carcinoma is 10%-17% [3]. Diagnosis of cirrhosis in CHB patients may trigger early initiation of antiviral treatment, which improves clinical outcomes. Also, development of complications in such patients is monitored regularly [7,8]. Traditionally, cirrhosis has been diagnosed with the aid of clinical information, including laboratory and imaging data. However, such methods have their limitations, and a liver biopsy has usually been required to confirm a diagnosis of liver cirrhosis. Cirrhosis occurs in response to chronic liver injury and constitutes the final stage of progressive hepatic fibrosis characterized by distortion of hepatic architecture and formation of regenerative nodules [9]. If a liver biopsy sample is to be adequately diagnostic, the sample should be at least 2-3 cm in length and contain more than 11 complete portal tracts [10]. However, it is usually difficult to fulfill these requirements. Also, the evaluation of simultaneous biopsies taken from the left and right lobes yielded different fibrosis scores in 33% of patients [11]. Intra- and inter-observer variation contribute to test variability [12]. Biopsy is associated with a bleeding risk of 1% [13] and a mortality rate of approximately 0.01% [14]. Therefore, it is necessary to investigate the new diagnostic methods for improving the limitations and complications of liver biopsy. Non-invasive modalities, including transient elastography (TE), acoustic radiation force impulse imaging (ARFI), real-time elastography (RTE), and magnetic resonance elastography (MRE), have been developed to overcome the problems discussed above. Also, markers of cirrhosis have been sought in blood. Such non-invasive modalities have attracted much attention [15-22]. In the present review, we examine the roles played by non-invasive diagnostic modalities in terms of assessment of cirrhosis and prediction of the prognosis of CHB patients. CLASSICAL DIAGNOSIS OF LIVER CIRRHOSIS USING CLINICAL INFORMATION Clinicians usually take a clinical history, conduct a physical examination, and review laboratory and imaging data to diagnose liver cirrhosis in CHB patients. First, history-taking is a basic clinical approach. For example, a family or past history of HBV infection is an important clue to decide whether cirrhosis may or may not be caused by HBV. The histories of blood transfusion, needle injury, and sexual activity are important factors for the route of infection. Second, physical examination is both simple and essential. Spider angioma, splenomegaly, hepatomegaly, a distended abdomen, the presence of shifting fluid, and pitting edema suggestive of portal hypertension, all aid in the diagnosis of liver cirrhosis in CHB patients. Blood samples should be evaluated for the presence of HBV surface antigen, platelet count, albumin level, prothrombin time, and total bilirubin concentration. Simple blood test data do not afford great sensitivity in diagnosis of cirrhosis, but one meta-analysis found that the presence of ascites [likelihood ratio (LR) = 7.2], a platelet count < 160000/mm 3 (LR = 6.3), and spider nevi (LR = 4.3) were all usefully predictive of cirrhosis [23]. These simple blood tests, and data from physical examination, are necessary to evaluate the severity of cirrhosis, being parameters used to derive Child-Pugh or Model for End-Stage Liver Disease (MELD) scores for cirrhotic patients. Third, imaging modalities including ultrasound, abdominal computed tomography (CT), and magnetic resonance imaging (MRI), can aid in detection of cirrhosis or hepatocellular carcinoma in HBV patients. Liver cirrhosis is typically associated with splenomegaly, hepatomegaly, a coarse echo pattern of the liver parenchyma, nodularity of the liver surface, a blunt angle, ascites, and thrombus of the portal vein [24-27]. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of ultrasound used to predict the presence of HBV-related cirrhosis were 77.8%, 92.5%, 87.5%, 86.0%, and 86.6%, respectively, and were higher in CHB patients than in those with chronic hepatitis C (CHC) [27]. Such radiological findings are also important when abdominal CT or MRI is used to diagnose liver cirrhosis. Additionally, other radiological findings including the velocity of portal flow, the shape of the hepatic vein waveform (as revealed by Doppler testing), and the caudate lobe/right lobe ratio with use of the main or right portal vein to set the lateral boundary (as revealed on CT or MRI), are useful [24,28-30]. Of these parameters, a caudate lobe/right lobe ratio over 0.65 is suggestive of the presence of liver cirrhosis. The sensitivity, specificity, and accuracy of this measure were 84%, 100%, and 94%, respectively [30]. Liver surface nodularity, a platelet count less than 100000/mm 3, an albumin level less than 3.5 g/dl, and an international normalized prothrombin time ratio of 1.3 or more, are also associated with liver cirrhosis. Each of these findings is associated with a specificity and sensitivity of 90% and 61%, respectively, in terms of cirrhosis diagnosis [31]. An overview of clinical history, physical examination, and review of laboratory and imaging test data, combine to aid in the diagnosis of HBV-caused cirrhosis. The use 446 January 14, 2014 Volume 20 Issue 2

of clinical strategies that combine elements of these diagnostic modalities is crucial to diagnose cirrhosis in CHB patients and to plan suitable treatment. TRANSIENT ELASTOGRAPHY Measurement of liver stiffness TE is a representative noninvasive method used to diagnose cirrhosis or assess the extent of fibrosis using ultrasound elastography. The propagation velocity of transient shear waves of low amplitude and frequency (50 Hz) is affected by the elasticity of the liver parenchyma. If the waves propagate rapidly, the fibrotic burden is large [32]. The outcome is expressed as a pressure (thus in kilopascals; kpa) and ranges from 2.5 to 75 kpa (normal, 5 kpa) [33-35]. The reliability of the technique has been reported to be over 60% and the median interquartile range less than 30% [36-38]. The generator is placed over an interspace of the ribcage of the right upper quadrant. The test usually takes 5-10 min. Typically, 10 or more measurements are taken but three valid measurements suffice to reliably diagnose liver fibrosis in CHB patients [39]. Diagnostic performance Most studies have found that TE performs well when used to diagnose and measure the extent of liver fibrosis in patients with CHC infection or other liver conditions [40-42]. TE also afforded acceptable diagnostic accuracy in CHB patients [18-20]. Marcellin et al [20] reported that TE used to diagnose cirrhosis in CHB patients had a diagnostic accuracy of 94%, a sensitivity of 57%, a specificity of 97%, a PPV of 67%, and an NPV of 96%. When maximal sensitivity and specificity are required, the cutoff value falls to 11.0 kpa (sensitivity 93%, specificity 87%, PPV 38%, and NPV 99%). Chan et al [19] found that TE yielded a good diagnostic performance in clinical practice. The maximal diagnostic accuracy was associated with a cutoff of 13.4 kpa but this value was 12.0 kpa when the sum of sensitivity and specificity was maximized. A liver stiffness measurement (LSM) cutoff value can easily be determined for each particular clinical requirement. A highly sensitive cutoff is useful when screening for earlystage cirrhosis whereas a highly specific cutoff would aid in detection of significant fibrosis or cirrhosis. A cutoff affording a high diagnostic accuracy would be valuable to ensure correct diagnosis. Interestingly, the cutoffs obtained by maximizing the sum of sensitivity and specificity, the area under the receiver operating characteristic (AUROC) curve, and diagnostic accuracy, were slightly lower for CHB than CHC patients. This is because the extent of fibrosis is slightly less in the former patients [43]. Cirrhosis in CHB patients is more macronodular in nature than in patients with CHC or alcoholic liver disease. Kim et al [44] found that LSMs and biopsy data were not in agreement with measures of necro-inflammatory activity in CHB patients. LSMs were significantly higher in cirrhotic patients in whom such activity was maximal (grades 3-4; grade 4 is termed F4) than when the activity was less (grades 1-2) (median of 19.2 kpa in the former patients vs 11.9 kpa in the latter; P = 0.009). The results of liver biopsy and LSM differed in CHB patients with cirrhosis, principally when necro-inflammatory activity of grades 3-4 significantly increased the LSMs. In addition, serum levels of aminotransferases must be considered when interpreting TE data from hepatitis B patients because alanine aminotransferase (ALT) flares (which are frequent in CHB patients) cause TE values to be artificially inflated [45]. Thus, patients with higher ALT levels tend to have greater LSMs than do those with lower ALT levels, even when the stage of liver fibrosis is identical. Thus, TE values of CHB patients should be interpreted cautiously because it is possible that patients with low-grade fibrosis may score as false-negatives whereas those with high ALT levels may yield falsepositive values. In patients with normal ALT levels, the optimal cutoff values for reliable detection of cirrhosis ranged from 8.4 to 12.0 kpa. However, in patients with elevated ALT levels [> 1-5-fold the upper limit of normal (ULN)], the optimal cutoff values ranged from 8.4 to 13.4 kpa [19]. Kim et al [46] suggested that an appropriate LSM cutoff value in CHB patients with ALT ULN was 10.1 kpa, but 15.5 in those with ALT > ULN and ALT < 2 ULN. When only patients with ALT < ULN were studied, the cutoff values allowing discrimination of each stage of fibrosis were reduced, and the sum of LSM sensitivity and specificity increased. Both the total bilirubin level and the time of performance of LSM have been explored in terms of the ability to predict development of cirrhosis in CHB patients. The total bilirubin level was significantly associated with changes in LSMs. However, the LSM was not reduced when measured soon after the levels of ALT and total bilirubin normalized [47]. This suggests that normalization of the LSM may occur only after laboratory measurements on serum return to normal. Therefore, biochemical findings should be well-stabilized before LSMs can be considered reliable. LSM data did not differ when the detector was placed in the fifth, sixth, and seventh intercostal spaces [48]. All LSMs accurately predicted development of cirrhosis. It was not necessary that the site of LSM should correspond to the liver biopsy site in cirrhotic HBV patients. A meta-analysis of 50 studies found that the mean AUROC for reliable diagnosis of significant fibrosis and cirrhosis was 0.94, with an optimal cutoff LSM of 13.01 kpa [49]. TE diagnosed severe fibrosis or cirrhosis more reliably than less advanced fibrotic stages. The data suggest that TE is an excellent tool for use in clinical practice to confirm the presence of cirrhosis when other clinical data are not definitive. Another meta-analysis of the data of nine studies showed that use of TE to diagnose cirrhosis was associated with 87% sensitivity and 91% specificity [50]. TE affords good diagnostic accuracy when used to quantify the extent of liver fibrosis in patients with either CHB or CHC. Chon et al [51] performed a meta-analysis of 18 stud- 447 January 14, 2014 Volume 20 Issue 2

Diagnostic performance ARFI SWV diagnostic cutoff values of 1.75-2.00 m/s have been reported in patients with liver cirrhosis [62-67]. Chen et al [68] explored the association between spleen stiffness and advanced liver fibrosis. The optimal cutoff value was 3.32 m/s for detection of cirrhosis (80.0% sensitivity, 88.4% specificity, 55.5% PPV, 96.0% NPV). However, these data should be interpreted with caution because the proportion of HBV patients in the tested population was too small to allow the diagnostic performance of ARFI in cirrhotic HBV patients to be evaluated. ARFI has been used to examine patients with a variety of liver diseases, principally hepatitis C infection. Friedrich-Rust et al [69] were the first to use ARFI to assess the severity of liver fibrosis in HBV patients. In this prospective European multicenter study, the median SWV was 0.76-2.96 m/s in CHB patients. In terms of Metavir fibrosis scores, the median velocities were 1.10 m/s for F0 patients, 1.14 m/s for F1 patients, 1.23 m/s for F2 patients, 1.60 m/s for F3 patients, and 1.75 m/s for F4 patients. The accuracy of cirrhosis diagnosis was 0.97. The cutoff for diagnosis of significant fibrosis (F grade 2) was 1.39 m/s with a sensitivity of 50%, a specificity of 90%, a PPV of 67%, an NPV of 73%, a positive likelihood ratio of 5.125, and a negative likelihood ratio of 0.554. However, no optimal cutoff for diagnosis of cirrhosis in CHB patients was derived, because the number of patients with F3/F4 fibrosis was too small. The diagnostic accuracy of ARFI in HBV patients with different degrees of fibrosis was lower than reported in previous studies on CHC patients who had fibrosis ranging from mild to significant, or cirrhosis. The accuracy of ARFI when used to detect mild fibrosis was 66% in HBV patients compared to 73% in studies on patients with CHC and other liver diseases. The accuracy values were 73% and 82%-90% in patients with significant fibrosis, 94% and 90%-99% in those with severe fibrosis, and similar (97% and 87%-99%) in those with cirrhosis [62-72]. Further randomized prospective studies are required to determine whether ARFI data are influenced by underlying liver disease. One meta-analysis reviewed 36 reports on ARFI imies with 2772 patients and found that the cutoff value for detection of cirrhosis in Asian CHB patients was 11.7 kpa, with a sensitivity and specificity of 84.6% and 81.5%, respectively. The mean AUROC for diagnosis of cirrhosis was 0.929. Advantages and disadvantages of TE TE data are reproducible and the results have been validated in detail. The procedure time is less than 5 min. It is easy to evaluate patients either at the bedside or in the outpatient clinic. TE is useful when employed to followup disease progression and to predict hepatic events preceding cirrhosis [52]. However, it is difficult to obtain TE data from obese patients [those with a body mass index (BMI) above 28 kg/m 2 ] and patients with narrow intercostal spaces, ascites, space-occupying tissue abnormalities, extrahepatic cholestasis, or congestion [15,53,54]. The difficulty of reliably measuring liver stiffness in patients with ascites is a major disadvantage, because ascites is a typical sign of cirrhosis. Recently, an XL TE probe (as distinct from the standard M probe) has been used to gather data from obese patients. The XL probe afforded the best diagnostic performance of all probes tested and a relatively low level of measurement failure [55]. Compared to the M probe, the XL probe operates at a lower frequency (3.5 MHz vs 5 MHz), is longer (ultrasound transducer focal length of 50 mm vs 35 mm), yields vibration of greater amplitude (peak-to-peak 3 mm vs 2 mm), and has a greater depth of measurement (35-75 mm vs 25-65 mm). Failure of LSM using the M probe occurred in 29.1% of patients with BMIs of 30 kg/m 2 or more, but the failure rate was only 6.8% when the XL probe was employed. Interestingly, eating prior to performance of TE can compromise the accuracy of LSMs in both CHC patients and those with other conditions [56,57]. The impact of ingestion on liver stiffness values is proportional to the stage of fibrosis, being maximal in patients with cirrhosis. This is because liver stiffness increases as portal blood flow and the hepatic vein pressure gradient rise after a meal [58]. Therefore, it is necessary for a patient to fast for at least 2 h prior to performance of TE. ACOUSTIC RADIATION FORCE IMPULSE IMAGING Measurement of liver stiffness ARFI, which employs conventional B-mode sonography, is an alternative to TE. ARFI mechanically excites tissue for a brief period via delivery of a high-intensity acoustic pulse to a region of interest (ROI). Shear waves propagate and generate localized tissue displacement [59]. The shear-wave velocity (SWV) is recorded in m/s and quantified in a region smaller than that examined when TE is employed (10 mm long and 6 mm wide). The ROI can be chosen by the operator. The SWV increases with stiffness. Thus, the SWV is an intrinsic and reproducible property of tissue [59-61]. The probe is usually placed between the ribs on the right side (e.g., in segment 8) to reduce the effect of cardiac motion on measurement. Thus, the device is located approximately where a liver biopsy is usually performed 1 cm under the capsule. Minimal scanning pressure is applied and the patient is asked to stop breathing for a moment, to minimize motion [62-64]. Data can also be obtained from the left lobe, which always appears to be stiffer than the right lobe, although data from both lobes correlate well with the stage of fibrosis [65]. The difference in measurement may be explained by variation in the pressure with which the ultrasonographic probe is placed. The probe is not directly applied to the right lobe because the chest wall intervenes to prevent direct probe contact with the liver. 448 January 14, 2014 Volume 20 Issue 2

aging of CHB patients and those with other liver diseases. In terms of diagnosis of patients of F grade 3, the mean AUROCs of studies including and excluding HBV patients were 0.87 (95%CI: 0.85-0.90) and 0.92 (95%CI: 0.89-0.95), respectively [73]. Thus, AFRI afforded good diagnostic accuracy when used to detect cirrhosis. Advantages and disadvantages In contrast to TE, ARFI yields real-time information on the extent of liver stiffness during observation using B-mode ultrasonography. Also, liver tissue can be directly targeted, with exclusion of small non-parenchymatous areas (for example, blood vessels). If a patient has a large right-side tumor or ascites, it is difficult to measure LSM using TE. In such instances, ARFI can be employed to diagnose cirrhosis. As ARFI is performed using a conventional ultrasound instrument, ARFI and standard ultrasound examination may be performed using the same machine in the same session. This is convenient for CHB patients, who are usually examined ultrasonographically once or twice per year. The major disadvantage of ARFI is that no long-term follow-up validation studies have been performed. Also, ARFI values, in contrast to TE values, have a narrow range (0.5-4.4 m/s). This makes it difficult to define precise cutoff values that can be used to make decisions on patient management. Cassinotto et al [55] reported that ARFI was (like TE) less efficient in obese patients. This is because the ultrasound beam travels poorly through thick fatty soft tissue. Thus, ARFI cannot be used as a first-line examination modality for obese patients. An advantage of ARFI is the ability to measure LSM in both the right and left lobes of the liver. However, upon simultaneous liver biopsy of both lobes, a betweenlobe difference of at least one fibrosis stage was noted in only 33% of patients, and liver cirrhosis was evident in only one biopsy in 14.5% of cases [11]. Acute cellular infiltration, increased central venous pressure, and cholestasis, can cause the extent of liver fibrosis to be overestimated. These possibilities should be considered when interpreting elastography data [74-76]. As is true of TE measurements, food intake also increases ARFI-measured liver stiffness [77]. REAL-TIME ELASTOGRAPHY Measurement of liver stiffness RTE is a novel noninvasive ultrasound modality measuring liver elasticity, and has recently been used to quantitatively assess the extent of liver fibrosis [78-81]. As with ARFI, RTE uses a modified version of standard ultrasound equipment. RTE propagates a shear wave through the liver and echo signals are captured in real time. Friedrich-Rust et al [79] and Kanamoto et al [82] examined the utility of RTE in evaluation of liver fibrosis. No special skills are required. A patient is placed in a supine position with the right arm extended above the head to stretch the intercostal muscles. After B-mode examination, the elastographic mode is selected. It is easy to verify the position of the liver because the elastographic images may be superimposed on B-mode reference images. The probe pressure may be varied manually. A small compression plate is usually attached to the ultrasonic probe so that stable tissue compression is attained and the stress field transmitted more uniformly. Tissue elasticity is color-coded (red: soft; blue: hard) in terms of magnitude and superimposed on conventional two-dimensional (2D) images [83], allowing anatomical correspondence to be noted. Diagnostic performance Only a few reports on use of RTE to evaluate CHB patients have appeared. Xie et al [84] used RTE to calculate elastic strain ratios (elastic strain values of liver tissue in the ROI/strain values of intercostal muscle in the ROI) in patients with different degrees of liver fibrosis. The diagnostic cut-off ratios were 1.10 in patients with substantial liver fibrosis and 0.60 in those with cirrhosis. The detection sensitivities for substantial fibrosis and cirrhosis were 77.8% and 50.0%, respectively, and the specificities 80.0% and 96.7%. The positive predictive values were 80.0% and 71.4% and the negative predictive values 77.8% and 92.2%. Wang et al [85] described the diagnostic performance of an elasticity index obtained using RTE, and the aspartate aminotransferase (AST) to platelet ratio index (APRI) used to stage liver fibrosis in CHB patients. The AU- ROCs for detection of cirrhosis were 0.66 and 0.23, respectively. The diagnostic accuracies of both tests used to assess the stage of liver fibrosis (except cirrhosis) in CHB patients were high. In terms of elasticity index distribution by Metavir fibrosis stage, the cut-off value was 90.31 for cirrhosis. Advantages and disadvantages RTE reveals relative tissue strain in real time by measuring tissue displacement. RTE can be used (as can ARFI) to evaluate liver fibrosis patients with ascites or who are severely obese. Eleven stiffness parameters are measured, and changes in tissue stiffness are thus evaluated systematically and sensitively. However, RTE requires further clinical validation. Although strain images are usually clear, artifacts include multiple reflections at the surface of the liver; echo-free areas filled by thick blood vessels, ribs and lungs; and lack of wave penetration. Also, if the probe pressure is excessive, the elastic relationship will vary (elasticity is nonlinear). In addition, pressure is not uniformly transmitted to the liver because that tissue is slightly deformed by heartbeats. However, good images can be obtained simply by applying the probe lightly to right-side intercostal regions. New quantitative analysis systems can measure tissue compression caused by the rhythmic beats of the heart and blood vessels; no manual compression is required. This minimizes the capacity for human error. 449 January 14, 2014 Volume 20 Issue 2

MAGNETIC RESONANCE ELASTOGRAPHY Measurement of liver stiffness MRE is not yet widely available. The technique uses a modified phase-contrast method to image the propagative characteristics of a shear wave traversing the liver [86]. A probe is placed against the patient s back. Measurements are obtained from the anterior segment of the right lobe (the region of the liver that is usually biopsied). Liver stiffness is measured by delineating an ROI of at least 100 mm 2 in the liver parenchyma, avoiding the edges of the tissue, large vessels (> 3 mm in diameter), and fissures. Low-frequency vibrations are emitted and the MRI spin echo sequence is used to gather data. Mean liver stiffness is expressed in kpa using a formula deriving a shear modulus, which is one-third the modulus of Young used in TE evaluation [87]. Diagnostic performance From a clinical viewpoint, MRE affords excellent accuracy when used to differentiate significant fibrosis from mild fibrosis or absence of fibrosis, and cirrhosis from other stages of liver fibrosis [88,89]. MRE has a high negative predictive value (97%) when used to exclude the presence of fibrosis [90]. A meta-analysis reviewing five studies employing MRE showed that the technique performed well diagnostically when used to evaluate liver cirrhosis attributable to different causes. The sensitivity of the technique was 92% and the specificity 96% when used differentiate F0-2 fibrosis from fibrosis of grades F3-4 [91]. Venkatesh et al [92] found that MRE was an accurate non-invasive method when used to detect and stage fibrosis in CHB patients. The diagnostic performance of MRE was significantly higher than those of serum fibrosis markers. The optimally discriminatory cutoff MRE value was 4.33 kpa for diagnosis of cirrhosis in CHB patients, with a sensitivity of 100%, a specificity of 100%, a PPV of 91.3%, and an NPV of 100%. Use of MRE was associated with a 14.3% error rate. Therefore, MRE is a valuable non-invasive test when used to detect and stage liver fibrosis in CHB patients. Interestingly, the MRE cutoff value for diagnosis of cirrhosis in CHB patients (4.33 kpa) was lower than that reported for CHC patients (6.20 kpa) [93] but similar to that associated with diagnosis of advanced fibrosis in NASH patients (4.3 kpa) [94]. This suggests that the cutoff values of diagnostic MRE data differ for diseases that vary in etiology. However, such results require confirmation in large-scale studies. Advantages and disadvantages MRE affords a significantly higher accuracy and technical success rate than other non-invasive modalities. MRE scans the entire liver and thus does not select an acoustic window. MRE can be used to evaluate obese patients or those with ascites. MRE can be easily incorporated into routine liver MRI; clinicians can simultaneously assess structural disease, liver stiffness, and fat and iron levels. Serum ALT level is a known confounding factor when fibrosis is detected using TE; liver stiffness is positively correlated with serum ALT levels [95,96]. However, MRE has exhibited no such association [89], probably because MRE and TE assess different mechanical properties. However, MRE is quite expensive, and is not yet widely available. MRE cannot be used to evaluate patients who are claustrophobic or fitted with heart pacemakers. MRE is more time-consuming than are other ultrasoundbased elastographic methods. MRE cannot be performed on iron-overloaded livers because of signal-to-noise limitations. SERUM BIOMARKERS Measurement of liver stiffness Diagnostic serum biomarkers of liver fibrosis and cirrhosis have been well-validated. Although marker levels are highly reproducible, they are not specific for liver disease and do not allow easy discrimination of intermediate stages of fibrosis [95]. Score panels based on combined blood test data are also of limited utility in differentiating the stages of fibrosis. Biomarkers detect cirrhosis more readily than intermediate stages of fibrosis [97,98]. However, the clinical utility of markers in diagnosis of liver cirrhosis requires further verification. Diagnostic performance Several serum markers have been evaluated in terms of the ability to diagnose liver cirrhosis. These include the FibroTest, the APRI, the prothrombin index (PI), the AST/ALT ratio (the AAR), the Lok index, and the Goteborg University cirrhosis index (the GUCI) [99,100]. The FibroTest and biopsy data performed similarly when used to diagnosis significant fibrosis in CHC patients [98,101-104]. One large study (of 913 CHC and 284 HBV patients) prospectively compared the most popular patented tests (the FibroTest, the Fibrometre, and the Hepacore) with a nonpatented test (the APRI); the AUROC values for cirrhosis ranged from 0.77 to 0.86 and no significant among-test differences in scores were evident [105]. Although nonpatented tests such as the Forns index, the FIB-4, and the APRI may lack the performance of the patented tests, the former tests are inexpensive, easy to perform, and widely available. However, few serum biomarkers have been evaluated in terms of the ability to define the stage of liver cirrhosis in CHB patients. The results of studies on CHC patients cannot be directly applied to CHB patients because CHB infection is associated with a specific type of pathogenesis. Thus, dedicated validation of marker utility in CHB patients is required. The FibroTest has been studied extensively over the last 5 years and is currently the best-understood serum marker panel used to detect fibrosis [106]. Application of 450 January 14, 2014 Volume 20 Issue 2

the FibroTest to CHB patients was associated with AU- ROCs of 0.77-0.78 for detection of significant fibrosis and cirrhosis, with 85.0% sensitivity and 52.0% specificity [107,108]. The APRI is a simple test that combines AST level with platelet count to predict the occurrence of significant fibrosis and cirrhosis in CHC patients. Venkatesh et al [92] showed that serum AST levels differed significantly between patients with low-grade and advanced fibrosis, but ALT levels did not. The APRI was helpful for discriminating CHB patients with advanced fibrosis from those with mild-to-moderate conditions. When the APRI cutoff was set at 0.5 for CHB patients, the AUROC for prediction of significant fibrosis was 0.673 [109] and the PPV and NPV 30% and 87%, respectively. In other words, the APRI can reliably be used to exclude the presence of significant fibrosis. Hui et al [109] developed a predictive model based on body mass index (BMI) and the data of three routine laboratory tests, which had an AUROC of 0.79 when used to assess the fibrosis stage of CHB patients. The laboratory data were bilirubin, albumin, platelet, and ALP levels. The PPV was 38% when a cutoff of 0.15 was applied and 53% when the cutoff was 0.5. The results suggest that the model should be used primarily to identify patients lacking significant fibrosis. Sebastiani et al [110] reported that sequential use of the APRI, the FibroTest, and liver biopsy data, greatly improved diagnostic performance compared to use of a single non-invasive test in CHB patients. The sequential combination was developed to detect cirrhosis in HBV patients. The need for liver biopsy was reduced by 50%-80%. All of the FibroTest, the APRI, the AAR, and the GUCI were only 77.5%-86.1% accurate in terms of cirrhosis detection when used individually. The FibroTest showed the best PPV, NPV, and AUROC for cirrhosis detection (90%, 87.1%, and 0.76, respectively). However, the sequential combination afforded excellent accuracy (100%) in terms of detection. Stepwise combination algorithms featuring the APRI, the FibroTest, and biopsy, afforded excellent performance (0.95 AUROC and 98.3% NPV for cirrhosis). Montazeri et al [111] suggested that serum hyaluronate level might predict extensive liver fibrosis and inflammation in CHB patients. Zhang et al [112] suggested that use of the APRI test in combination with hyaluronic acid (HA) measurement could serve to detect moderate-to-severe fibrosis in CHB patients. When the APRI was used alone to this end, the sensitivity, specificity, PPV, and NPV were 44.7%, 84.3%, 41.3%, and 84.7%, respectively. The diagnostic performance of the APRI was low in terms of discrimination of fibrosis stages in such patients. However, when an APRI score of 1.5 was used in combination with an HA cutoff of > 300 ng/ml, moderate-to-severe fibrosis was accurately predicted in CHB patients (98.9% of specificity and 93.7% of PPV). Lebensztejn et al [113] reported that the AUROC of combined hyaluronan and laminin measurements was 0.84. Zeng et al [114] developed a non-invasive combination model including age and measurements of serum alpha- 2-macroglobulin, hyaluronan, and γ-glutamyl transpeptidase. The AUROCs were 0.77-0.84. The expected rate of misdiagnosis was around 20%, similar to that reported in hepatitis C patients. However, it may be inappropriate to apply the test in real clinical settings. Recently, proteome technology has been used to study liver fibrosis. A total of 30 features predictive of significant fibrosis and cirrhosis were identified in 46 CHB patients. The AUROCs were high, being 0.906 and 0.921 for detection of advanced fibrosis and cirrhosis, respectively [115]. However, the method is rather complicated and may not be applicable to large-scale testing. A meta-analysis [116] of data from 30 studies using the FibroTest and biopsy (3501 CHC and 1457 CHB patients) found that the mean standardized AUROC for diagnosis of significant fibrosis was 0.84, and did not differ significantly between patients with CHC (0.85) and CHB (0.80). Advantages and disadvantages The inter-laboratory reproducibilities of the FibroMeter, FibroTest, and APRI tests, and combinations thereof, are excellent [117]. The APRI test is inexpensive and widely available (being nonpatented). However, these tests perform less well than does TE in terms of cirrhosis diagnosis. Also, test results are not immediately available [95]. The tests are not specific for liver disease and do not discriminate among the intermediate stages of fibrosis. Test results can be influenced by comorbidities, and critical data interpretation is required. False-positive FibroTest and Hepascore results are yielded by patients with Gilbert s syndrome or hemolysis, because such patients exhibit hyperbilirubinemia [118]. Similarly, acute hepatitis can produce false-positive results in the APRI, Forns index, FIB-4, or Fibrometer tests. DIAGNOSIS OF DECOMPENSATED CIRRHOSIS Recently, noninvasive ultrasound- and MRI-based elastographic techniques have allowed the relationships between liver or spleen stiffness and portal pressure to be explored. Use of TE revealed a statistically significant association of these parameters with the hepatic venous pressure gradient of CHC patients [119,120], and a correlation with the grade of esophageal varices was evident [121]. Talwalkar et al [122] used MRE to show that splenomegaly, mean spleen stiffness, and serum platelet count were potentially associated with the presence of esophageal varices. Neither the mean liver stiffness value nor the mean spleen volume was significantly associated with the presence of esophageal varices. A cutoff spleen stiffness value of over 10.5 kpa identified all cirrhotic patients with esophageal varices. Ye et al [123] reported that the liver stiffness cutoff value of ARFI was 1.88 m/s for diagnosis of liver cirrhosis in 451 January 14, 2014 Volume 20 Issue 2

CHB patients (AUROC = 0.97; sensitivity, 95.7%; specificity, 91.8). Interestingly, spleen stiffness values were also determined in the cited study, to aid in diagnosis of cirrhosis and esophageal varices. The spleen stiffness cutoff value was 2.72 m/s for diagnosis of liver cirrhosis (AUROC = 0.96; sensitivity, 88.4%; specificity, 93.2%). The optimal spleen stiffness cutoff predicting varices was 3.16 m/s (AUROC = 0.83). In this report, portal hypertensions could not be graded according to liver stiffness, but a significant linear correlation was evident between spleen stiffness and varices grade. COMPARISONS OF MODALITIES USED TO DIAGNOSE CIRRHOSIS TE and ARFI Lupsor et al [66] found that both ARFI and TE data were strongly correlated with the stage of fibrosis, and TE was superior when used to predict early-stage disease in patients with chronic hepatitis C. However, Ebinuma et al [65] found that the diagnostic powers of the two techniques were almost identical. Neither mode detected low-grade fibrosis effectively, but diagnostic capacities rose as the stage of fibrosis advanced. ARFI and TE were compared in a meta-analysis of eight studies involving 518 patients. TE afforded a slightly higher diagnostic accuracy for cirrhosis (mean AUROC difference: 0.04) [124]. The mean AUROC of all published studies on the use of ARFI to detect cirrhosis in CHB patients was 0.90. However, most studies had small sample numbers and the study populations were heterogeneous. Friedrich-Rust et al [69] found that ARFI and TE performed similarly when used to diagnose liver fibrosis in CHB patients. ARFI afforded excellent performance when used to diagnose advanced fibrosis, but differentiation of mild fibrosis was in need of improvement. When a low cutoff of 1.03 m/s was used to exclude significant fibrosis, and a high cutoff of 1.39 m/s to confirm significant fibrosis, 38% of patients were correctly classified using ARFI. Cassinotto et al [55] compared the use of ARFI, TE with the M and XL probes, and the FibroTest, in evaluation of 321 patients (39 with HBV infections). In terms of cirrhosis diagnosis, no significant difference was evident between ARFI elastography and TE with the M or XL probes. However, the diagnostic performance of TE was significantly better than that of the FibroTest. Comparison of TE and MRE In a comparative study, MRE was superior to both TE and APRI when used to assess liver fibrosis, affording accuracies of over 98% in diagnosis of all categories of fibrosis [89]. The AUROC of MRE was 0.998 for diagnosis of liver cirrhosis and the technical success rate was higher than that associated with ultrasound elastography (AUROC = 0.930), APRI (AUROC = 0.820), and a combination of TE with APRI (AUROC = 0.944). Comparison of RTE and other elastographic modalities Colombo et al [125] compared the utility of TE, RTE, and ARFI in diagnosis of liver fibrosis. TE and ARFI exhibited high diagnostic accuracies (AUROCs 0.9) when used to diagnose cirrhosis. All three methods afforded fair (AUROC = 0.7) to good (AUROC = 0.8) diagnostic accuracy when used to diagnose all fibrosis (F1-4 Metavir grades) and significant fibrosis (F2-4 Metavir grades). Of the various modalities, TE exhibited the best diagnostic performance (AUROCs of 0.878 for fibrosis and 0.897 for significant fibrosis, respectively). TE and ARFI were highly accurate when used to diagnose cirrhosis. Friedrich-Rust et al [79] found that the AUROCs for diagnosis of significant fibrosis and cirrhosis using TE and RTE were 0.84 vs 0.69, and 0.97 vs 0.65, respectively. RTE was less accurate than TE when used to predict liver fibrosis. However, upon direct comparison of TE, RTE, and ARFI in 74 Korean patients, the cut-off values for diagnosis of cirrhosis were 8.60 kpa (AUROC = 0.786; sensitivity, 81.0%; specificity, 64.2%); 1.39 m/s (AUROC = 0.807; sensitivity, 90.5%; specificity, 66.0%); and 2.79 (AUROC = 0.767; sensitivity, 81.0%; specificity, 64.2%), respectively [126]. TE and ARFI, rather than RTE, are the best modalities for non-invasive assessment of liver fibrosis. However, all three methods reliably predict cirrhosis. Comparison of elastography and serum biomarker measurements In terms of detection of cirrhosis, AUROC analysis indicated that the APRI test was superior to the elastic strain ratio determined using real-time elastography, and the Forns index [84]. This suggests that the APRI should be used to diagnose cirrhosis in preference to calculation of the elastic strain ratio. When the AUROCs of spleen stiffness measurement and APRI were compared, the overall diagnostic performance of the former test in prediction of liver fibrosis stages was superior to that of the APRI [68]. The diagnostic accuracy of the FibroTest was comparable to those of elastographic methods. APRI scoring has been shown to be inferior to FibroTest- and TE-based evaluations [127,128]. Other methods for diagnosis of liver cirrhosis Hu et al [129] measured newly maximal accumulative respiration strain (MARS) values obtained from hepatic tissue image analysis of CHB patients. Each value represents the average strain of hepatic tissue in the ROI at different stages of the respiratory cycle. The MARS values were correlated with fibrotic stage. The diagnostic accuracy rate for cirrhosis had an AUROC of 0.75. However, the performance of MARS was inferior to that of TE. COMBINATION OF LSM WITH OTHER MODELS OF FIBROSIS PREDICTION The use of combination models has been proposed to 452 January 14, 2014 Volume 20 Issue 2

Table 1 Diagnostic performance of non-invasive diagnostic methods in predicting cirrhosis with chronic hepatitis B Ref. Year Modality Patients (n ) Cut-offs F4 Standard reference AUROC Se Sp Accuracy PPV NPV Myers et al [107] 2003 Biomarkers 209 0.2 1 Biopsy 0.780 85.0% 52.0% - 43.0 92.0 0.4 1 54.0% 80.0% - 53.0 81.0 0.8 1 18.0% 99.0% - 92.0 75.0 Hui et al [109] 2005 Biomarkers 235 > 0.15 1 Biopsy 0.791 88.0% 50.0% 93.0 38.0 92.0 > 0.5 1 0.791 37.0% 88.0% - 53.0 81.0 Zeng et al [114] 2005 Biomarkers 200 > 3.0 1 Biopsy 0.770 94.8% 44.1% - 70.1 86.1 > 8.7 1 0.770 35.3% 95.2% - 91.1 51.6 Marcellin et al [20] 2009 TE 173 18.2 kpa 2 Biopsy 0.930 57.0% 97.0% 94.0 67.0 96.0 11 kpa 2 Biopsy 0.930 93.0% 87.0% 38.0 38.0 99.0 Chan et al [19] 2009 TE 161 13.4 kpa 2 Biopsy 0.930 75.0% 93.0% 89.0 78.0 92.0 12 kpa 3 79.0% 92.0% - 76.0 93.0 Kim et al [18] 2009 TE 91 10.3 kpa Biopsy 0.803 59.0% 78.0% - 68.0 72.0 Kim et al [52] 2010 TE 104 10.1 kpa Biopsy 0.849 86.7% 88.1% - 87.5 77.1 TE 52 15.5 kpa 0.867 66.7% 100.0% - 100.0 72.9 Kim et al [138] 2010 LSPI 4 330 38 5 Biopsy 0.956 98.0% 69.2% - 82.9 95.7 62 5 85.9% 93.8% - 95.5 81.3 42 6 96.3% 67.4% - 73.3 95.1 94 6 67.5% 97.7% - 96.4 76.4 Hu et al [129] 2010 MARS 28 20.32% Biopsy 0.750 100.0% - - - - Ye et al [123] 2011 ARFI 264 1.88 m/s Biopsy 0.970 95.7% 91.8% - - - Spleen ARFI 2.72 m/s 0.960 88.4% 93.2% - - - Xie et al [84] 2012 RTE 7 71-0.6 Biopsy 0.797 50.0% 96.7% - 71.4 92.2 APRI 71 Biopsy 0.930 - - - - - Wang et al [85] 2012 RTE 75 90.31 Biopsy 0.660 71.4% 80.0% - 93.8 40.0 APRI 75 Biopsy 0.930 - - - - - Cassinotto et al [55] 2013 TE 8 285 14.1 kpa Biopsy 0.910 77.0% 92.0% 89.0 74.0 93.0 TE 9 254 10.1 kpa Biopsy 0.880 85.0% 82.0% 82.0 76.0 96.0 Friedrich-Rust et al [69] 2013 ARFI 92 Biopsy 0.970 - - - - - TE 92 Biopsy 0.930 - - - - - Venkatesh et al [92] 2013 MRE 64 4.33 kpa Biopsy 0.980 100.0% 95.2% - 91.3 100.0 1 cut-off value for significant fibrosis; 2 cut-off value with maximum of diagnosis accuracy; 3 cut off value with a maximum sum of sensitivity and specificity; 4 Liver stiffness measurement spleen diameter/platelet count; 5 cut-off value with normal alanine aminotransferase (ALT); 6 cut-off value with high ALT; 7 Elastic strand ratio; 8 M probe; 9 XL probe. LSPI: Liver stiffness measurement - spleen diameter to platelet ratio index; TE: Transient elastography; ARFI: Acoustic radiation force impulse imaging; RTE: Real-time elastography; MRE: Magnetic resonance elastography; MARS: Maximal accumulative respiration strain; Se: sensitivity; Sp: specificity; PPV: Positive predictive value; NPV: Negative predictive value; AUROC: Area under the receiver operating characteristic. increase the diagnostic performance of tests for liver cirrhosis, although elastography alone accurately predicts histological cirrhosis. The combined use of the Enhanced Liver Fibrosis (ELF) test with either ARFI or TE in patients with multi-origin cirrhosis increased the diagnostic accuracy of liver cirrhosis [130]. The PPV and NPV of ARFI-plus-ELF were 73% and 100%, and those of TE-plus-ELF 64% and 100%, respectively. The ultimate validation of liver fibrosis as a marker of liver injury is the prognostic value thereof in terms of morbidity and mortality. In recent studies on non-chb patients, the TE test and measures of serum fibrosis markers were prognostically more valuable than liver biopsy data [131-133]. However, long-term follow-up studies on ARFI are required. Chung et al [126] explored the efficacies of combinations of LSM modalities (TE, ARFI, and RTE) with platelet count in terms of increasing the diagnostic power for liver disease of varying etiology. Cutoff ratios of LSM/(platelet count) used to predict cirrhosis were no more effective than the LSM data alone. However, the ratios predicted significant fibrosis (grade F2) more effectively than did LSM data alone. The diagnostic performance of TE in CHB patients can be improved by combining test data with those of fibrosis serum marker levels derived using the APRI, Fib-4, Fibrometer and FibroTest [134-136]. Wong et al [137] reported that agreement between a high LSM and a high Forns index value improved diagnostic specificity (from 99% to 100% and from 87% to 98% in training and validation cohorts, respectively). Kim et al [138] derived optimal predictive threshold values of the LSM/spleen diameter to platelet ratio index (LSPI; LSM spleen diameter/ platelet count) for detection of cirrhosis in terms of ALT level. The AUROC was 0.956, thus slightly higher than the AUROC of 0.919 afforded by use of TE data alone. When used to diagnose cirrhosis in patients with normal ALT levels, use of an LSPI predictive threshold value of 38 was associated with 98.0% sensitivity and 69.2% specificity, whereas a threshold value of 62 was associated with 85.9% sensitivity and 93.8% specificity. Similarly, in a high-level ALT group, an LSPI predictive threshold value of 42 was associated with 96.3% sensitivity and 67.4% specificity, whereas a threshold of 94 was associated with 67.5% sensitivity and 97.7% specificity. Kim et al [46] found that optimal LSM cutoff values varied with ALT level, and use of an index (a ratio) combining data on age, spleen size, and platelet level, enhanced 453 January 14, 2014 Volume 20 Issue 2

LSM performance when used to diagnose cirrhosis in CHB patients (AUROCs = 0.917 in patients with ALT upper ULN; 0.909 in those with ALT 2 ULN; and 0.894 in all patients). Evaluation of hepatitis B patients using elastography increased the accuracy of these measures when used to diagnose cirrhosis. Increasing acceptance of the utility of combination modalities is expected to reduce the requirement for liver biopsy. The combination methods enhance diagnostic accuracy and reduce the number of liver biopsies needed to evaluate cirrhotic CHB patients. An optimal choice of diagnostic modality requires the conduct of large-scale validation studies in a variety of patient populations. Also, the cost-effectiveness of combination models requires future attention. CONCLUSION The last decade has seen significant progress in development of noninvasive liver disease assessment in CHB patients (Table 1). It has become accepted that liver biopsy has limitations when used to diagnose cirrhosis. TE, ARFI, RTE, and MRE are valuable for early diagnosis of cirrhosis in CHB patients because the AUROC values associated with use of these techniques are in excess of 0.8 [139]. Routine use of TE in management of hepatitis C patients has significantly reduced the need for liver biopsy [140], but reliable detection of mild fibrosis and accurate differentiation of fibrotic stages remain problematic [141-143]. In addition, accurate measurements may be difficult to obtain from obese patients, those with ascites, and those exhibiting severe hepatic atrophy. Acoustic radiation force impulse imaging is a novel form of ultrasound providing in vivo information on the local mechanical properties of tissue [144,145]. However, ARFI cannot be used to evaluate patients who are obese or cirrhotic patients with very stiff tissue because imaging results are automatically rejected if detection of low-frequency acoustic wave propagation is inadequate [63]. RTE does not have such limitations and can be used to image almost all patients, including those who cannot be assessed by TE or ARFI. MRE was more accurate than either ultrasoundbased elastography or measurement of serum markers of fibrosis [88,89,93]. However, most previous studies on RTE and MRE included patients with chronic liver disease of various etiologies. RTE and MRE should be validated in CHB cohorts (with macronodular cirrhosis) in particular. TE is the most widely used method for diagnosis of cirrhosis in CHB patients, but ARFI and MRE may be equally valuable. Novel techniques including supersonic shear imaging [146,147] or measurement of spleen stiffness [148] may also be valuable in diagnosis of liver cirrhosis. A combination of elastography and biomarker measurements may improve diagnostic performance during surveillance of CHB patients for development of liver cirrhosis. However, clinical benefit must be weighed against cost when a combined approach is planned. REFERENCES 1 Perz JF, Armstrong GL, Farrington LA, Hutin YJ, Bell BP. The contributions of hepatitis B virus and hepatitis C virus infections to cirrhosis and primary liver cancer worldwide. J Hepatol 2006; 45: 529-538 [PMID: 16879891 DOI: 10.1016/ j.jhep.2006.05.013] 2 European Association For The Study Of The Liver. EASL clinical practice guidelines: Management of chronic hepatitis B virus infection. J Hepatol 2012; 57: 167-185 [PMID: 22436845 DOI: 10.1016/j.jhep.2012.02.010] 3 Fattovich G, Bortolotti F, Donato F. Natural history of chronic hepatitis B: special emphasis on disease progression and prognostic factors. J Hepatol 2008; 48: 335-352 [PMID: 18096267 DOI: 10.1016/j.jhep.2007.11.011] 4 D Amico G, Garcia-Tsao G, Pagliaro L. Natural history and prognostic indicators of survival in cirrhosis: a systematic review of 118 studies. J Hepatol 2006; 44: 217-231 [PMID: 16298014 DOI: 10.1016/j.jhep.2005.10.013] 5 Arvaniti V, D Amico G, Fede G, Manousou P, Tsochatzis E, Pleguezuelo M, Burroughs AK. Infections in patients with cirrhosis increase mortality four-fold and should be used in determining prognosis. Gastroenterology 2010; 139: 1246-156, 1246-156, [PMID: 20558165 DOI: 10.1053/ j.gastro.2010.06.019] 6 Fede G, D Amico G, Arvaniti V, Tsochatzis E, Germani G, Georgiadis D, Morabito A, Burroughs AK. Renal failure and cirrhosis: a systematic review of mortality and prognosis. J Hepatol 2012; 56: 810-818 [PMID: 22173162 DOI: 10.1016/ j.jhep.2011.10.016] 7 Lok AS, McMahon BJ. Chronic hepatitis B: update 2009. Hepatology 2009; 50: 661-662 [PMID: 19714720 DOI: 10.1002/ hep.23190] 8 European Association For The Study Of The Liver. [EASL clinical practice guidelines. Management of chronic hepatitis B]. Gastroenterol Clin Biol 2009; 33: 539-554 [PMID: 19481389 DOI: 10.1016/j.gcb.2009.03.002] 9 Ishak K, Baptista A, Bianchi L, Callea F, De Groote J, Gudat F, Denk H, Desmet V, Korb G, MacSween RN. Histological grading and staging of chronic hepatitis. J Hepatol 1995; 22: 696-699 [PMID: 7560864] 10 Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD. Liver biopsy. Hepatology 2009; 49: 1017-1044 [PMID: 19243014 DOI: 10.1002/hep.22742] 11 Regev A, Berho M, Jeffers LJ, Milikowski C, Molina EG, Pyrsopoulos NT, Feng ZZ, Reddy KR, Schiff ER. Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection. Am J Gastroenterol 2002; 97: 2614-2618 [PMID: 12385448 DOI: 10.1111/j.1572-0241.2002.06038.x] 12 Intraobserver and interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C. The French METAVIR Cooperative Study Group. Hepatology 1994; 20: 15-20 [PMID: 8020885] 13 Weigand K, Weigand K. Percutaneous liver biopsy: retrospective study over 15 years comparing 287 inpatients with 428 outpatients. J Gastroenterol Hepatol 2009; 24: 792-799 [PMID: 19220661 DOI: 10.1111/j.1440-1746.2008.05718.x] 14 Bravo AA, Sheth SG, Chopra S. Liver biopsy. N Engl J Med 2001; 344: 495-500 [PMID: 11172192 DOI: 10.1056/ NEJM200102153440706] 15 Sandrin L, Fourquet B, Hasquenoph JM, Yon S, Fournier C, Mal F, Christidis C, Ziol M, Poulet B, Kazemi F, Beaugrand M, Palau R. Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. Ultrasound Med Biol 2003; 29: 1705-1713 [PMID: 14698338] 16 Seo YS. [Transient elastography, true or false?]. Korean J Hepatol 2009; 15: 431-437 [PMID: 20037261 DOI: 10.3350/ kjhep.2009.15.4.431] 17 Kim SG, Kim YS, Jung SW, Kim HK, Jang JY, Moon JH, Kim HS, Lee JS, Lee MS, Shim CS, Kim BS. [The usefulness 454 January 14, 2014 Volume 20 Issue 2

of transient elastography to diagnose cirrhosis in patients with alcoholic liver disease]. Korean J Hepatol 2009; 15: 42-51 [PMID: 19346784 DOI: 10.3350/kjhep.2009.15.1.42] 18 Kim do Y, Kim SU, Ahn SH, Park JY, Lee JM, Park YN, Yoon KT, Paik YH, Lee KS, Chon CY, Han KH. Usefulness of FibroScan for detection of early compensated liver cirrhosis in chronic hepatitis B. Dig Dis Sci 2009; 54: 1758-1763 [PMID: 19005758 DOI: 10.1007/s10620-008-0541-2] 19 Chan HL, Wong GL, Choi PC, Chan AW, Chim AM, Yiu KK, Chan FK, Sung JJ, Wong VW. Alanine aminotransferasebased algorithms of liver stiffness measurement by transient elastography (Fibroscan) for liver fibrosis in chronic hepatitis B. J Viral Hepat 2009; 16: 36-44 [PMID: 18673426 DOI: 10.1111/j.1365-2893.2008.01037.x] 20 Marcellin P, Ziol M, Bedossa P, Douvin C, Poupon R, de Lédinghen V, Beaugrand M. Non-invasive assessment of liver fibrosis by stiffness measurement in patients with chronic hepatitis B. Liver Int 2009; 29: 242-247 [PMID: 18637064 DOI: 10.1111/j.1478-3231.2008.01802.x] 21 Cho SW, Cheong JY. [Clinical application of non-invasive diagnosis for hepatic fibrosis]. Korean J Hepatol 2007; 13: 129-137 [PMID: 17585186] 22 Bae RC, Cho HJ, Oh JT, Lee EK, Heo J, Shin KY, Park SY, Jeong MK, Jeon SW, Cho CM, Tak WY, Kweon YO. [Clinical factors influencing liver stiffness as measured by transient elastography (Fibroscan) in patients with chronic liver disease]. Korean J Hepatol 2010; 16: 123-130 [PMID: 20606496 DOI: 10.3350/kjhep.2010.16.2.123] 23 Udell JA, Wang CS, Tinmouth J, FitzGerald JM, Ayas NT, Simel DL, Schulzer M, Mak E, Yoshida EM. Does this patient with liver disease have cirrhosis? JAMA 2012; 307: 832-842 [PMID: 22357834 DOI: 10.1001/jama.2012.186] 24 Aubé C, Oberti F, Korali N, Namour MA, Loisel D, Tanguy JY, Valsesia E, Pilette C, Rousselet MC, Bedossa P, Rifflet H, Maïga MY, Penneau-Fontbonne D, Caron C, Calès P. Ultrasonographic diagnosis of hepatic fibrosis or cirrhosis. J Hepatol 1999; 30: 472-478 [PMID: 10190731] 25 Colli A, Fraquelli M, Andreoletti M, Marino B, Zuccoli E, Conte D. Severe liver fibrosis or cirrhosis: accuracy of US for detection--analysis of 300 cases. Radiology 2003; 227: 89-94 [PMID: 12601199 DOI: 10.1148/radiol.2272020193] 26 Di Lelio A, Cestari C, Lomazzi A, Beretta L. Cirrhosis: diagnosis with sonographic study of the liver surface. Radiology 1989; 172: 389-392 [PMID: 2526349] 27 Hung CH, Lu SN, Wang JH, Lee CM, Chen TM, Tung HD, Chen CH, Huang WS, Changchien CS. Correlation between ultrasonographic and pathologic diagnoses of hepatitis B and C virus-related cirrhosis. J Gastroenterol 2003; 38: 153-157 [PMID: 12640529 DOI: 10.1007/s005350300025] 28 Baik SK, Kim JW, Kim HS, Kwon SO, Kim YJ, Park JW, Kim SH, Chang SJ, Lee DK, Han KH, Um SH, Lee SS. Recent variceal bleeding: Doppler US hepatic vein waveform in assessment of severity of portal hypertension and vasoactive drug response. Radiology 2006; 240: 574-580 [PMID: 16864678 DOI: 10.1148/radiol.2402051142] 29 Harbin WP, Robert NJ, Ferrucci JT. Diagnosis of cirrhosis based on regional changes in hepatic morphology: a radiological and pathological analysis. Radiology 1980; 135: 273-283 [PMID: 7367613] 30 Awaya H, Mitchell DG, Kamishima T, Holland G, Ito K, Matsumoto T. Cirrhosis: modified caudate-right lobe ratio. Radiology 2002; 224: 769-774 [PMID: 12202712 DOI: 10.1148/ radiol.2243011495] 31 Lee HS, Kim JK, Cheong JY, Han EJ, An SY, Song JH, Jung YJ, Jeon SC, Jung MW, Jang EJ, Cho SW. Prediction of compensated liver cirrhosis by ultrasonography and routine blood tests in patients with chronic viral hepatitis. Korean J Hepatol 2010; 16: 369-375 [PMID: 21415580 DOI: 10.3350/ kjhep.2010.16.4.369] 32 Yeh WC, Li PC, Jeng YM, Hsu HC, Kuo PL, Li ML, Yang PM, Lee PH. Elastic modulus measurements of human liver and correlation with pathology. Ultrasound Med Biol 2002; 28: 467-474 [PMID: 12049960 DOI: 10.1016/ S0301-5629(02)00489-1] 33 Roulot D, Czernichow S, Le Clésiau H, Costes JL, Vergnaud AC, Beaugrand M. Liver stiffness values in apparently healthy subjects: influence of gender and metabolic syndrome. J Hepatol 2008; 48: 606-613 [PMID: 18222014 DOI: 10.1016/j.jhep.2007.11.020] 34 Kim SU, Choi GH, Han WK, Kim BK, Park JY, Kim do Y, Choi JS, Yang SC, Choi EH, Ahn SH, Han KH, Chon CY. What are true normal liver stiffness values using FibroScan?: a prospective study in healthy living liver and kidney donors in South Korea. Liver Int 2010; 30: 268-274 [PMID: 19929903 DOI: 10.1111/j.1478-3231.2009.02172.x] 35 Colombo S, Belloli L, Zaccanelli M, Badia E, Jamoletti C, Buonocore M, Del Poggio P. Normal liver stiffness and its determinants in healthy blood donors. Dig Liver Dis 2011; 43: 231-236 [PMID: 20817625 DOI: 10.1016/j.dld.2010.07.008] 36 Castéra L, Foucher J, Bernard PH, Carvalho F, Allaix D, Merrouche W, Couzigou P, de Lédinghen V. Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations. Hepatology 2010; 51: 828-835 [PMID: 20063276 DOI: 10.1002/hep.23425] 37 Myers RP, Crotty P, Pomier-Layrargues G, Ma M, Urbanski SJ, Elkashab M. Prevalence, risk factors and causes of discordance in fibrosis staging by transient elastography and liver biopsy. Liver Int 2010; 30: 1471-1480 [PMID: 20807336 DOI: 10.1111/j.1478-3231.2010.02331.x] 38 Castera L, Forns X, Alberti A. Non-invasive evaluation of liver fibrosis using transient elastography. J Hepatol 2008; 48: 835-847 [PMID: 18334275 DOI: 10.1016/j.jhep.2008.02.008] 39 Jang HW, Kim SU, Park JY, Ahn SH, Han KH, Chon CY, Park YN, Choi EH, Kim do Y. How many valid measurements are necessary to assess liver fibrosis using FibroScan in patients with chronic viral hepatitis? An analysis of subjects with at least 10 valid measurements. Yonsei Med J 2012; 53: 337-345 [PMID: 22318821 DOI: 10.3349/ymj.2012.53.2.337] 40 Castéra L, Vergniol J, Foucher J, Le Bail B, Chanteloup E, Haaser M, Darriet M, Couzigou P, De Lédinghen V. Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C. Gastroenterology 2005; 128: 343-350 [PMID: 15685546 DOI: 10.1053/j.gastro.2004.11.018] 41 Ziol M, Handra-Luca A, Kettaneh A, Christidis C, Mal F, Kazemi F, de Lédinghen V, Marcellin P, Dhumeaux D, Trinchet JC, Beaugrand M. Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C. Hepatology 2005; 41: 48-54 [PMID: 15690481 DOI: 10.1002/hep.20506] 42 Lupşor M, Badea R, Stefănescu H, Grigorescu M, Sparchez Z, Serban A, Branda H, Iancu S, Maniu A. Analysis of histopathological changes that influence liver stiffness in chronic hepatitis C. Results from a cohort of 324 patients. J Gastrointestin Liver Dis 2008; 17: 155-163 [PMID: 18568136] 43 Gaia S, Carenzi S, Barilli AL, Bugianesi E, Smedile A, Brunello F, Marzano A, Rizzetto M. Reliability of transient elastography for the detection of fibrosis in non-alcoholic fatty liver disease and chronic viral hepatitis. J Hepatol 2011; 54: 64-71 [PMID: 20932598 DOI: 10.1016/j.jhep.2010.06.022] 44 Kim SU, Kim JK, Park YN, Han KH. Discordance between liver biopsy and Fibroscan in assessing liver fibrosis in chronic hepatitis b: risk factors and influence of necroinflammation. PLoS One 2012; 7: e32233 [PMID: 22384189 DOI: 10.1371/journal.pone.0032233] 45 Yuen MF, Yuan HJ, Hui CK, Wong DK, Wong WM, Chan AO, Wong BC, Lai CL. A large population study of spontaneous HBeAg seroconversion and acute exacerbation of chronic hepatitis B infection: implications for antiviral therapy. Gut 2003; 52: 416-419 [PMID: 12584226 DOI: 10.1136/ 455 January 14, 2014 Volume 20 Issue 2

gut.52.3.416] 46 Kim SU, Kim do Y, Park JY, Lee JH, Ahn SH, Kim JK, Paik YH, Lee KS, Chon CY, Choi EH, Song KJ, Park YN, Han KH. How can we enhance the performance of liver stiffness measurement using FibroScan in diagnosing liver cirrhosis in patients with chronic hepatitis B? J Clin Gastroenterol 2010; 44: 66-71 [PMID: 19609218 DOI: 10.1097/ MCG.0b013e3181a95c7f] 47 Kim SU, Han KH, Park JY, Ahn SH, Chung MJ, Chon CY, Choi EH, Kim do Y. Liver stiffness measurement using FibroScan is influenced by serum total bilirubin in acute hepatitis. Liver Int 2009; 29: 810-815 [PMID: 19018979 DOI: 10.1111/j.1478-3231.2008.01894.x] 48 Kim SU, Kim JK, Park JY, Ahn SH, Lee JM, Baatarkhuu O, Choi EH, Han KH, Chon CY, Kim do Y. Variability in liver stiffness values from different intercostal spaces. Liver Int 2009; 29: 760-766 [PMID: 19413672 DOI: 10.1111/ j.1478-3231.2009.02035.x] 49 Friedrich-Rust M, Ong MF, Martens S, Sarrazin C, Bojunga J, Zeuzem S, Herrmann E. Performance of transient elastography for the staging of liver fibrosis: a meta-analysis. Gastroenterology 2008; 134: 960-974 [PMID: 18395077 DOI: 10.1053/j.gastro.2008.01.034] 50 Talwalkar JA, Kurtz DM, Schoenleber SJ, West CP, Montori VM. Ultrasound-based transient elastography for the detection of hepatic fibrosis: systematic review and meta-analysis. Clin Gastroenterol Hepatol 2007; 5: 1214-1220 [PMID: 17916549 DOI: 10.1016/j.cgh.2007.07.020] 51 Chon YE, Choi EH, Song KJ, Park JY, Kim do Y, Han KH, Chon CY, Ahn SH, Kim SU. Performance of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B: a meta-analysis. PLoS One 2012; 7: e44930 [PMID: 23049764 DOI: 10.1371/journal.pone.0044930] 52 Kim SU, Han KH, Ahn SH. Non-invasive assessment of liver fibrosis: time to move from cross-sectional studies to longitudinal ones. J Gastroenterol Hepatol 2010; 25: 1472-1473 [PMID: 20796140 DOI: 10.1111/j.1440-1746.2010.06432.x] 53 Foucher J, Castéra L, Bernard PH, Adhoute X, Laharie D, Bertet J, Couzigou P, de Lédinghen V. Prevalence and factors associated with failure of liver stiffness measurement using FibroScan in a prospective study of 2114 examinations. Eur J Gastroenterol Hepatol 2006; 18: 411-412 [PMID: 16538113] 54 Castera L, Pinzani M. Biopsy and non-invasive methods for the diagnosis of liver fibrosis: does it take two to tango? Gut 2010; 59: 861-866 [PMID: 20581229 DOI: 10.1136/ gut.2010.214650] 55 Cassinotto C, Lapuyade B, Aït-Ali A, Vergniol J, Gaye D, Foucher J, Bailacq-Auder C, Chermak F, Le Bail B, de Lédinghen V. Liver fibrosis: noninvasive assessment with acoustic radiation force impulse elastography--comparison with FibroScan M and XL probes and FibroTest in patients with chronic liver disease. Radiology 2013; 269: 283-292 [PMID: 23630312 DOI: 10.1148/radiol.13122208] 56 Arena U, Lupsor Platon M, Stasi C, Moscarella S, Assarat A, Bedogni G, Piazzolla V, Badea R, Laffi G, Marra F, Mangia A, Pinzani M. Liver stiffness is influenced by a standardized meal in patients with chronic hepatitis C virus at different stages of fibrotic evolution. Hepatology 2013; 58: 65-72 [PMID: 23447459 DOI: 10.1002/hep.26343] 57 Mederacke I, Wursthorn K, Kirschner J, Rifai K, Manns MP, Wedemeyer H, Bahr MJ. Food intake increases liver stiffness in patients with chronic or resolved hepatitis C virus infection. Liver Int 2009; 29: 1500-1506 [PMID: 19732330 DOI: 10.1111/j.1478-3231.2009.02100.x] 58 Berzigotti A, De Gottardi A, Vukotic R, Siramolpiwat S, Abraldes JG, García-Pagan JC, Bosch J. Effect of meal ingestion on liver stiffness in patients with cirrhosis and portal hypertension. PLoS One 2013; 8: e58742 [PMID: 23520531 DOI: 10.1371/journal.pone.0058742] 59 Nightingale K, Soo MS, Nightingale R, Trahey G. Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility. Ultrasound Med Biol 2002; 28: 227-235 [PMID: 11937286 DOI: 10.1016/S0301-5629(01)00499-9] 60 Zhai L, Palmeri ML, Bouchard RR, Nightingale RW, Nightingale KR. An integrated indenter-arfi imaging system for tissue stiffness quantification. Ultrason Imaging 2008; 30: 95-111 [PMID: 18939611] 61 Mauldin FW, Zhu HT, Behler RH, Nichols TC, Gallippi CM. Robust principal component analysis and clustering methods for automated classification of tissue response to ARFI excitation. Ultrasound Med Biol 2008; 34: 309-325 [PMID: 17913334 DOI: 10.1016/j.ultrasmedbio.2007.07.019] 62 Friedrich-Rust M, Wunder K, Kriener S, Sotoudeh F, Richter S, Bojunga J, Herrmann E, Poynard T, Dietrich CF, Vermehren J, Zeuzem S, Sarrazin C. Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography. Radiology 2009; 252: 595-604 [PMID: 19703889 DOI: 10.1148/radiol.2523081928] 63 Goertz RS, Zopf Y, Jugl V, Heide R, Janson C, Strobel D, Bernatik T, Haendl T. Measurement of liver elasticity with acoustic radiation force impulse (ARFI) technology: an alternative noninvasive method for staging liver fibrosis in viral hepatitis. Ultraschall Med 2010; 31: 151-155 [PMID: 20306380 DOI: 10.1055/s-0029-1245244] 64 Sporea I, Sirli RL, Deleanu A, Popescu A, Focsa M, Danila M, Tudora A. Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies. Ultraschall Med 2011; 32 Suppl 1: S46-S52 [PMID: 20603783 DOI: 10.1055/ s-0029-1245360] 65 Ebinuma H, Saito H, Komuta M, Ojiro K, Wakabayashi K, Usui S, Chu PS, Umeda R, Ishibashi Y, Takayama T, Kikuchi M, Nakamoto N, Yamagishi Y, Kanai T, Ohkuma K, Sakamoto M, Hibi T. Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan( ). J Gastroenterol 2011; 46: 1238-1248 [PMID: 21779759 DOI: 10.1007/s00535-011-0437-3] 66 Lupsor M, Badea R, Stefanescu H, Sparchez Z, Branda H, Serban A, Maniu A. Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results. J Gastrointestin Liver Dis 2009; 18: 303-310 [PMID: 19795024] 67 Haque M, Robinson C, Owen D, Yoshida EM, Harris A. Comparison of acoustic radiation force impulse imaging (ARFI) to liver biopsy histologic scores in the evaluation of chronic liver disease: A pilot study. Ann Hepatol 2010; 9: 289-293 [PMID: 20720270] 68 Chen SH, Li YF, Lai HC, Kao JT, Peng CY, Chuang PH, Su WP, Chiang IP. Noninvasive assessment of liver fibrosis via spleen stiffness measurement using acoustic radiation force impulse sonoelastography in patients with chronic hepatitis B or C. J Viral Hepat 2012; 19: 654-663 [PMID: 22863270 DOI: 10.1111/j.1365-2893.2012.01588.x] 69 Friedrich-Rust M, Buggisch P, de Knegt RJ, Dries V, Shi Y, Matschenz K, Schneider MD, Herrmann E, Petersen J, Schulze F, Zeuzem S, Sarrazin C. Acoustic radiation force impulse imaging for non-invasive assessment of liver fibrosis in chronic hepatitis B. J Viral Hepat 2013; 20: 240-247 [PMID: 23490368 DOI: 10.1111/j.1365-2893.2012.01646.x] 70 Kircheis G, Sagir A, Vogt C, Vom Dahl S, Kubitz R, Häussinger D. Evaluation of acoustic radiation force impulse imaging for determination of liver stiffness using transient elastography as a reference. World J Gastroenterol 2012; 18: 1077-1084 [PMID: 22416182 DOI: 10.3748/wjg.v18.i10.1077] 71 Sporea I, Sirli R, Popescu A, Danilă M. Acoustic Radiation Force Impulse (ARFI)--a new modality for the evaluation of liver fibrosis. Med Ultrason 2010; 12: 26-31 [PMID: 21165451] 72 Fierbinteanu-Braticevici C, Andronescu D, Usvat R, Cretoiu 456 January 14, 2014 Volume 20 Issue 2

D, Baicus C, Marinoschi G. Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis. World J Gastroenterol 2009; 15: 5525-5532 [PMID: 19938190 DOI: 10.3748/wjg.15.5525] 73 Nierhoff J, Chávez Ortiz AA, Herrmann E, Zeuzem S, Friedrich-Rust M. The efficiency of acoustic radiation force impulse imaging for the staging of liver fibrosis: a metaanalysis. Eur Radiol 2013; 23: 3040-3053 [PMID: 23801420 DOI: 10.1007/s00330-013-2927-6] 74 Coco B, Oliveri F, Maina AM, Ciccorossi P, Sacco R, Colombatto P, Bonino F, Brunetto MR. Transient elastography: a new surrogate marker of liver fibrosis influenced by major changes of transaminases. J Viral Hepat 2007; 14: 360-369 [PMID: 17439526 DOI: 10.1111/j.1365-2893.2006.00811.x] 75 Millonig G, Reimann FM, Friedrich S, Fonouni H, Mehrabi A, Büchler MW, Seitz HK, Mueller S. Extrahepatic cholestasis increases liver stiffness (FibroScan) irrespective of fibrosis. Hepatology 2008; 48: 1718-1723 [PMID: 18836992 DOI: 10.1002/hep.22577] 76 Millonig G, Friedrich S, Adolf S, Fonouni H, Golriz M, Mehrabi A, Stiefel P, Pöschl G, Büchler MW, Seitz HK, Mueller S. Liver stiffness is directly influenced by central venous pressure. J Hepatol 2010; 52: 206-210 [PMID: 20022130 DOI: 10.1016/j.jhep.2009.11.018] 77 Goertz RS, Egger C, Neurath MF, Strobel D. Impact of food intake, ultrasound transducer, breathing maneuvers and body position on acoustic radiation force impulse (ARFI) elastometry of the liver. Ultraschall Med 2012; 33: 380-385 [PMID: 22723037 DOI: 10.1055/s-0032-1312816] 78 Morikawa H, Fukuda K, Kobayashi S, Fujii H, Iwai S, Enomoto M, Tamori A, Sakaguchi H, Kawada N. Real-time tissue elastography as a tool for the noninvasive assessment of liver stiffness in patients with chronic hepatitis C. J Gastroenterol 2011; 46: 350-358 [PMID: 20697747 DOI: 10.1007/s00535-010-0301-x] 79 Friedrich-Rust M, Schwarz A, Ong M, Dries V, Schirmacher P, Herrmann E, Samaras P, Bojunga J, Bohle RM, Zeuzem S, Sarrazin C. Real-time tissue elastography versus FibroScan for noninvasive assessment of liver fibrosis in chronic liver disease. Ultraschall Med 2009; 30: 478-484 [PMID: 19813157 DOI: 10.1055/s-0028-1109488] 80 Sãftoiu A, Gheonea DI, Ciurea T. Hue histogram analysis of real-time elastography images for noninvasive assessment of liver fibrosis. AJR Am J Roentgenol 2007; 189: W232-W233 [PMID: 17885039 DOI: 10.2214/AJR.07.2571] 81 Friedrich-Rust M, Ong MF, Herrmann E, Dries V, Samaras P, Zeuzem S, Sarrazin C. Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitis. AJR Am J Roentgenol 2007; 188: 758-764 [PMID: 17312065 DOI: 10.2214/AJR.06.0322] 82 Kanamoto M, Shimada M, Ikegami T, Uchiyama H, Imura S, Morine Y, Kanemura H, Arakawa Y, Nii A. Real time elastography for noninvasive diagnosis of liver fibrosis. J Hepatobiliary Pancreat Surg 2009; 16: 463-467 [PMID: 19322509 DOI: 10.1007/s00534-009-0075-9] 83 Frey H. [Realtime elastography. A new ultrasound procedure for the reconstruction of tissue elasticity]. Radiologe 2003; 43: 850-855 [PMID: 14605701 DOI: 10.1007/s00117-003-0943-2] 84 Xie L, Chen X, Guo Q, Dong Y, Guang Y, Zhang X. Real-time elastography for diagnosis of liver fibrosis in chronic hepatitis B. J Ultrasound Med 2012; 31: 1053-1060 [PMID: 22733854] 85 Wang J, Guo L, Shi X, Pan W, Bai Y, Ai H. Real-time elastography with a novel quantitative technology for assessment of liver fibrosis in chronic hepatitis B. Eur J Radiol 2012; 81: e31-e36 [PMID: 21216123 DOI: 10.1016/j.ejrad.2010.12.013] 86 Muthupillai R, Lomas DJ, Rossman PJ, Greenleaf JF, Manduca A, Ehman RL. Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. Science 1995; 269: 1854-1857 [PMID: 7569924] 87 Talwalkar JA, Yin M, Fidler JL, Sanderson SO, Kamath PS, Ehman RL. Magnetic resonance imaging of hepatic fibrosis: emerging clinical applications. Hepatology 2008; 47: 332-342 [PMID: 18161879 DOI: 10.1002/hep.21972] 88 Huwart L, Sempoux C, Salameh N, Jamart J, Annet L, Sinkus R, Peeters F, ter Beek LC, Horsmans Y, Van Beers BE. Liver fibrosis: noninvasive assessment with MR elastography versus aspartate aminotransferase-to-platelet ratio index. Radiology 2007; 245: 458-466 [PMID: 17940304 DOI: 10.1148/ radiol.2452061673] 89 Huwart L, Sempoux C, Vicaut E, Salameh N, Annet L, Danse E, Peeters F, ter Beek LC, Rahier J, Sinkus R, Horsmans Y, Van Beers BE. Magnetic resonance elastography for the noninvasive staging of liver fibrosis. Gastroenterology 2008; 135: 32-40 [PMID: 18471441 DOI: 10.1053/j.gastro.2008.03.076] 90 Yin M, Talwalkar JA, Glaser KJ, Manduca A, Grimm RC, Rossman PJ, Fidler JL, Ehman RL. Assessment of hepatic fibrosis with magnetic resonance elastography. Clin Gastroenterol Hepatol 2007; 5: 1207-1213.e2 [PMID: 17916548 DOI: 10.1016/j.cgh.2007.06.012] 91 Wang QB, Zhu H, Liu HL, Zhang B. Performance of magnetic resonance elastography and diffusion-weighted imaging for the staging of hepatic fibrosis: A meta-analysis. Hepatology 2012; 56: 239-247 [PMID: 22278368 DOI: 10.1002/ hep.25610] 92 Venkatesh SK, Wang G, Lim SG, Wee A. Magnetic resonance elastography for the detection and staging of liver fibrosis in chronic hepatitis B. Eur Radiol 2014; 24: 70-78 [PMID: 23928932 DOI: 10.1007/s00330-013-2978-8] 93 Ichikawa S, Motosugi U, Ichikawa T, Sano K, Morisaka H, Enomoto N, Matsuda M, Fujii H, Araki T. Magnetic resonance elastography for staging liver fibrosis in chronic hepatitis C. Magn Reson Med Sci 2012; 11: 291-297 [PMID: 23269016] 94 Bensamoun SF, Leclerc GE, Debernard L, Cheng X, Robert L, Charleux F, Rhein C, Latrive JP. Cutoff values for alcoholic liver fibrosis using magnetic resonance elastography technique. Alcohol Clin Exp Res 2013; 37: 811-817 [PMID: 23216352 DOI: 10.1111/acer.12025] 95 Castera L. Noninvasive methods to assess liver disease in patients with hepatitis B or C. Gastroenterology 2012; 142: 1293-1302.e4 [PMID: 22537436 DOI: 10.1053/ j.gastro.2012.02.017] 96 Fraquelli M, Rigamonti C, Casazza G, Donato MF, Ronchi G, Conte D, Rumi M, Lampertico P, Colombo M. Etiologyrelated determinants of liver stiffness values in chronic viral hepatitis B or C. J Hepatol 2011; 54: 621-628 [PMID: 21146243 DOI: 10.1016/j.jhep.2010.07.017] 97 Rockey DC, Bissell DM. Noninvasive measures of liver fibrosis. Hepatology 2006; 43: S113-S120 [PMID: 16447288 DOI: 10.1002/hep.21046] 98 Halfon P, Bacq Y, De Muret A, Penaranda G, Bourliere M, Ouzan D, Tran A, Botta D, Renou C, Bréchot MC, Degott C, Paradis V. Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C. J Hepatol 2007; 46: 395-402 [PMID: 17156890 DOI: 10.1016/j.jhep.2006.09.020] 99 Lok AS, Ghany MG, Goodman ZD, Wright EC, Everson GT, Sterling RK, Everhart JE, Lindsay KL, Bonkovsky HL, Di Bisceglie AM, Lee WM, Morgan TR, Dienstag JL, Morishima C. Predicting cirrhosis in patients with hepatitis C based on standard laboratory tests: results of the HALT-C cohort. Hepatology 2005; 42: 282-292 [PMID: 15986415 DOI: 10.1002/ hep.20772] 100 Koda M, Matunaga Y, Kawakami M, Kishimoto Y, Suou T, Murawaki Y. FibroIndex, a practical index for predicting significant fibrosis in patients with chronic hepatitis C. Hepatology 2007; 45: 297-306 [PMID: 17256741 DOI: 10.1002/ hep.21520] 101 Parkes J, Guha IN, Roderick P, Rosenberg W. Performance of serum marker panels for liver fibrosis in chronic hepatitis C. J Hepatol 2006; 44: 462-474 [PMID: 16427156 DOI: 10.1016/ 457 January 14, 2014 Volume 20 Issue 2

j.jhep.2005.10.019] 102 Leroy V, Hilleret MN, Sturm N, Trocme C, Renversez JC, Faure P, Morel F, Zarski JP. Prospective comparison of six non-invasive scores for the diagnosis of liver fibrosis in chronic hepatitis C. J Hepatol 2007; 46: 775-782 [PMID: 17321634 DOI: 10.1016/j.jhep.2006.12.013] 103 Calès P, de Ledinghen V, Halfon P, Bacq Y, Leroy V, Boursier J, Foucher J, Bourlière M, de Muret A, Sturm N, Hunault G, Oberti F. Evaluating the accuracy and increasing the reliable diagnosis rate of blood tests for liver fibrosis in chronic hepatitis C. Liver Int 2008; 28: 1352-1362 [PMID: 18492022 DOI: 10.1111/j.1478-3231.2008.01789.x] 104 Zarski JP, Sturm N, Guechot J, Paris A, Zafrani ES, Asselah T, Boisson RC, Bosson JL, Guyader D, Renversez JC, Bronowicki JP, Gelineau MC, Tran A, Trocme C, De Ledinghen V, Lasnier E, Poujol-Robert A, Ziegler F, Bourliere M, Voitot H, Larrey D, Rosenthal-Allieri MA, Fouchard Hubert I, Bailly F, Vaubourdolle M. Comparison of nine blood tests and transient elastography for liver fibrosis in chronic hepatitis C: the ANRS HCEP-23 study. J Hepatol 2012; 56: 55-62 [PMID: 21781944 DOI: 10.1016/j.jhep.2011.05.024] 105 Degos F, Perez P, Roche B, Mahmoudi A, Asselineau J, Voitot H, Bedossa P. Diagnostic accuracy of FibroScan and comparison to liver fibrosis biomarkers in chronic viral hepatitis: a multicenter prospective study (the FIBROSTIC study). J Hepatol 2010; 53: 1013-1021 [PMID: 20850886 DOI: 10.1016/ j.jhep.2010.05.035] 106 Poynard T, Ratziu V, Benhamou Y, Thabut D, Moussalli J. Biomarkers as a first-line estimate of injury in chronic liver diseases: time for a moratorium on liver biopsy? Gastroenterology 2005; 128: 1146-118; author reply 1148 [PMID: 15825108] 107 Myers RP, Tainturier MH, Ratziu V, Piton A, Thibault V, Imbert-Bismut F, Messous D, Charlotte F, Di Martino V, Benhamou Y, Poynard T. Prediction of liver histological lesions with biochemical markers in patients with chronic hepatitis B. J Hepatol 2003; 39: 222-230 [PMID: 12873819] 108 Poynard T, Zoulim F, Ratziu V, Degos F, Imbert-Bismut F, Deny P, Landais P, El Hasnaoui A, Slama A, Blin P, Thibault V, Parvaz P, Munteanu M, Trepo C. Longitudinal assessment of histology surrogate markers (FibroTest-ActiTest) during lamivudine therapy in patients with chronic hepatitis B infection. Am J Gastroenterol 2005; 100: 1970-1980 [PMID: 16128941 DOI: 10.1111/j.1572-0241.2005.41957.x] 109 Hui AY, Chan HL, Wong VW, Liew CT, Chim AM, Chan FK, Sung JJ. Identification of chronic hepatitis B patients without significant liver fibrosis by a simple noninvasive predictive model. Am J Gastroenterol 2005; 100: 616-623 [PMID: 15743360 DOI: 10.1111/j.1572-0241.2005.41289.x] 110 Sebastiani G, Vario A, Guido M, Alberti A. Sequential algorithms combining non-invasive markers and biopsy for the assessment of liver fibrosis in chronic hepatitis B. World J Gastroenterol 2007; 13: 525-531 [PMID: 17278217] 111 Montazeri G, Estakhri A, Mohamadnejad M, Nouri N, Montazeri F, Mohammadkani A, Derakhshan MH, Zamani F, Samiee S, Malekzadeh R. Serum hyaluronate as a non-invasive marker of hepatic fibrosis and inflammation in HBeAgnegative chronic hepatitis B. BMC Gastroenterol 2005; 5: 32 [PMID: 16221307 DOI: 10.1186/1471-230X-5-32] 112 Zhang YX, Wu WJ, Zhang YZ, Feng YL, Zhou XX, Pan Q. Noninvasive assessment of liver fibrosis with combined serum aminotransferase/platelet ratio index and hyaluronic acid in patients with chronic hepatitis B. World J Gastroenterol 2008; 14: 7117-7121 [PMID: 19084920] 113 Lebensztejn DM, Kaczmarski M, Sobaniec-Łotowska M, Bauer M, Voelker M, Schuppan D. Serum laminin-2 and hyaluronan predict severe liver fibrosis in children with chronic hepatitis B. Hepatology 2004; 39: 868-869 [PMID: 14999715 DOI: 10.1002/hep.20147] 114 Zeng MD, Lu LG, Mao YM, Qiu DK, Li JQ, Wan MB, Chen CW, Wang JY, Cai X, Gao CF, Zhou XQ. Prediction of significant fibrosis in HBeAg-positive patients with chronic hepatitis B by a noninvasive model. Hepatology 2005; 42: 1437-1445 [PMID: 16317674 DOI: 10.1002/hep.20960] 115 Poon TC, Hui AY, Chan HL, Ang IL, Chow SM, Wong N, Sung JJ. Prediction of liver fibrosis and cirrhosis in chronic hepatitis B infection by serum proteomic fingerprinting: a pilot study. Clin Chem 2005; 51: 328-335 [PMID: 15590748 DOI: 10.1373/clinchem.2004.041764] 116 Poynard T, Morra R, Halfon P, Castera L, Ratziu V, Imbert- Bismut F, Naveau S, Thabut D, Lebrec D, Zoulim F, Bourliere M, Cacoub P, Messous D, Munteanu M, de Ledinghen V. Meta-analyses of FibroTest diagnostic value in chronic liver disease. BMC Gastroenterol 2007; 7: 40 [PMID: 17937811 DOI: 10.1186/1471-230X-7-40] 117 Calès P, Veillon P, Konaté A, Mathieu E, Ternisien C, Chevailler A, Godon A, Gallois Y, Joubaud F, Hubert-Fouchard I, Oberti F, Réaud S, Hunault G, Mauriat F, Lunel-Fabiani F. Reproducibility of blood tests of liver fibrosis in clinical practice. Clin Biochem 2008; 41: 10-18 [PMID: 17988658 DOI: 10.1016/j.clinbiochem.2007.08.009] 118 Poynard T, Munteanu M, Imbert-Bismut F, Charlotte F, Thabut D, Le Calvez S, Messous D, Thibault V, Benhamou Y, Moussalli J, Ratziu V. Prospective analysis of discordant results between biochemical markers and biopsy in patients with chronic hepatitis C. Clin Chem 2004; 50: 1344-1355 [PMID: 15192028 DOI: 10.1373/clinchem.2004.032227] 119 Vizzutti F, Arena U, Romanelli RG, Rega L, Foschi M, Colagrande S, Petrarca A, Moscarella S, Belli G, Zignego AL, Marra F, Laffi G, Pinzani M. Liver stiffness measurement predicts severe portal hypertension in patients with HCVrelated cirrhosis. Hepatology 2007; 45: 1290-1297 [PMID: 17464971 DOI: 10.1002/hep.21665] 120 Carrión JA, Navasa M, Bosch J, Bruguera M, Gilabert R, Forns X. Transient elastography for diagnosis of advanced fibrosis and portal hypertension in patients with hepatitis C recurrence after liver transplantation. Liver Transpl 2006; 12: 1791-1798 [PMID: 16823833 DOI: 10.1002/lt.20857] 121 Kazemi F, Kettaneh A, N kontchou G, Pinto E, Ganne-Carrie N, Trinchet JC, Beaugrand M. Liver stiffness measurement selects patients with cirrhosis at risk of bearing large oesophageal varices. J Hepatol 2006; 45: 230-235 [PMID: 16797100 DOI: 10.1016/j.jhep.2006.04.006] 122 Talwalkar JA, Yin M, Venkatesh S, Rossman PJ, Grimm RC, Manduca A, Romano A, Kamath PS, Ehman RL. Feasibility of in vivo MR elastographic splenic stiffness measurements in the assessment of portal hypertension. AJR Am J Roentgenol 2009; 193: 122-127 [PMID: 19542403 DOI: 10.2214/ AJR.07.3504] 123 Ye XP, Ran HT, Cheng J, Zhu YF, Zhang DZ, Zhang P, Zheng YY. Liver and spleen stiffness measured by acoustic radiation force impulse elastography for noninvasive assessment of liver fibrosis and esophageal varices in patients with chronic hepatitis B. J Ultrasound Med 2012; 31: 1245-1253 [PMID: 22837289] 124 Friedrich-Rust M, Nierhoff J, Lupsor M, Sporea I, Fierbinteanu-Braticevici C, Strobel D, Takahashi H, Yoneda M, Suda T, Zeuzem S, Herrmann E. Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis. J Viral Hepat 2012; 19: e212-e219 [PMID: 22239521 DOI: 10.1111/j.1365-2893.2011.01537.x] 125 Colombo S, Buonocore M, Del Poggio A, Jamoletti C, Elia S, Mattiello M, Zabbialini D, Del Poggio P. Head-to-head comparison of transient elastography (TE), real-time tissue elastography (RTE), and acoustic radiation force impulse (ARFI) imaging in the diagnosis of liver fibrosis. J Gastroenterol 2012; 47: 461-469 [PMID: 22223175 DOI: 10.1007/ s00535-011-0509-4] 126 Chung JH, Ahn HS, Kim SG, Lee YN, Kim YS, Jeong SW, Jang JY, Lee SH, Kim HS, Kim BS. The usefulness of transient 458 January 14, 2014 Volume 20 Issue 2

elastography, acoustic-radiation-force impulse elastography, and real-time elastography for the evaluation of liver fibrosis. Clin Mol Hepatol 2013; 19: 156-164 [PMID: 23837140 DOI: 10.3350/cmh.2013.19.2.156] 127 Shaheen AA, Wan AF, Myers RP. FibroTest and FibroScan for the prediction of hepatitis C-related fibrosis: a systematic review of diagnostic test accuracy. Am J Gastroenterol 2007; 102: 2589-2600 [PMID: 17850410 DOI: 10.1111/ j.1572-0241.2007.01466.x] 128 Morra R, Lebray P, Ingiliz P, Ngo Y, Munteanu M, Ratziu V, Poynard T. FibroTest has better diagnostic and prognostic values than the aspartate aminotransferase-to-platelet ratio index in patients with chronic hepatitis C. Hepatology 2008; 47: 353-34; author reply 353-34; [PMID: 18161711 DOI: 10.1002/hep.22046] 129 Hu X, Shao J, Bai J, Wang J, Qian L. New noninvasive assessment of liver fibrosis in chronic hepatitis B: maximal accumulative respiration strain. J Ultrasound Med 2010; 29: 1213-1221 [PMID: 20660455] 130 Crespo G, Fernández-Varo G, Mariño Z, Casals G, Miquel R, Martínez SM, Gilabert R, Forns X, Jiménez W, Navasa M. ARFI, FibroScan, ELF, and their combinations in the assessment of liver fibrosis: a prospective study. J Hepatol 2012; 57: 281-287 [PMID: 22521355 DOI: 10.1016/j.jhep.2012.03.016] 131 Ngo Y, Munteanu M, Messous D, Charlotte F, Imbert-Bismut F, Thabut D, Lebray P, Thibault V, Benhamou Y, Moussalli J, Ratziu V, Poynard T. A prospective analysis of the prognostic value of biomarkers (FibroTest) in patients with chronic hepatitis C. Clin Chem 2006; 52: 1887-1896 [PMID: 16931569 DOI: 10.1373/clinchem.2006.070961] 132 Guha IN, Parkes J, Roderick P, Chattopadhyay D, Cross R, Harris S, Kaye P, Burt AD, Ryder SD, Aithal GP, Day CP, Rosenberg WM. Noninvasive markers of fibrosis in nonalcoholic fatty liver disease: Validating the European Liver Fibrosis Panel and exploring simple markers. Hepatology 2008; 47: 455-460 [PMID: 18038452 DOI: 10.1002/hep.21984] 133 Vergniol J, Foucher J, Mamou K, Castéra L, Bernard PH, Couzigou P, de Lédinghen V. Non-invasive evaluation of liver fibrosis using FibroScan in long-term sustained-virological responder patients after HCV treatment. Gastroenterol Clin Biol 2008; 32: 1061-1063 [PMID: 19019607 DOI: 10.1016/ j.gcb.2008.09.018] 134 Kim BK, Kim SU, Kim HS, Park JY, Ahn SH, Chon CY, Cho IR, Joh DH, Park YN, Han KH, Kim do Y. Prospective validation of FibroTest in comparison with liver stiffness for predicting liver fibrosis in Asian subjects with chronic hepatitis B. PLoS One 2012; 7: e35825 [PMID: 22536445 DOI: 10.1371/journal.pone.0035825] 135 Kim SU, Ahn SH, Park JY, Kang W, Kim do Y, Park YN, Chon CY, Han KH. Liver stiffness measurement in combination with noninvasive markers for the improved diagnosis of B-viral liver cirrhosis. J Clin Gastroenterol 2009; 43: 267-271 [PMID: 18987556 DOI: 10.1097/MCG.0b013e31816f212e] 136 Bonnard P, Sombié R, Lescure FX, Bougouma A, Guiard- Schmid JB, Poynard T, Calès P, Housset C, Callard P, Le Pendeven C, Drabo J, Carrat F, Pialoux G. Comparison of elastography, serum marker scores, and histology for the assessment of liver fibrosis in hepatitis B virus (HBV)-infected patients in Burkina Faso. Am J Trop Med Hyg 2010; 82: 454-458 [PMID: 20207872 DOI: 10.4269/ajtmh.2010.09-0088] 137 Wong GL, Wong VW, Choi PC, Chan AW, Chan HL. Development of a non-invasive algorithm with transient elastography (Fibroscan) and serum test formula for advanced liver fibrosis in chronic hepatitis B. Aliment Pharmacol Ther 2010; 31: 1095-1103 [PMID: 20180785 DOI: 10.1111/ j.1365-2036.2010.04276.x] 138 Kim BK, Han KH, Park JY, Ahn SH, Chon CY, Kim JK, Paik YH, Lee KS, Park YN, Kim do Y. A novel liver stiffness measurement-based prediction model for cirrhosis in hepatitis B patients. Liver Int 2010; 30: 1073-1081 [PMID: 20492510 DOI: 10.1111/j.1478-3231.2010.02269.x] 139 Swets JA. Measuring the accuracy of diagnostic systems. Science 1988; 240: 1285-1293 [PMID: 3287615] 140 Castera L, Denis J, Babany G, Roudot-Thoraval F. Evolving practices of non-invasive markers of liver fibrosis in patients with chronic hepatitis C in France: time for new guidelines? J Hepatol 2007; 46: 528-59; author reply 528-59; [PMID: 17239479 DOI: 10.1016/j.jhep.2006.12.002] 141 de Lédinghen V, Vergniol J. Transient elastography for the diagnosis of liver fibrosis. Expert Rev Med Devices 2010; 7: 811-823 [PMID: 21050091 DOI: 10.1586/erd.10.46] 142 Melodelima D, Bamber JC, Duck FA, Shipley JA. Transient elastography using impulsive ultrasound radiation force: a preliminary comparison with surface palpation elastography. Ultrasound Med Biol 2007; 33: 959-969 [PMID: 17445967 DOI: 10.1016/j.ultrasmedbio.2006.12.004] 143 Obara N, Ueno Y, Fukushima K, Nakagome Y, Kakazu E, Kimura O, Wakui Y, Kido O, Ninomiya M, Kogure T, Inoue J, Kondo Y, Shiina M, Iwasaki T, Yamamoto T, Shimosegawa T. Transient elastography for measurement of liver stiffness measurement can detect early significant hepatic fibrosis in Japanese patients with viral and nonviral liver diseases. J Gastroenterol 2008; 43: 720-728 [PMID: 18807134 DOI: 10.1007/s00535-008-2225-2] 144 Rizzo L, Calvaruso V, Cacopardo B, Alessi N, Attanasio M, Petta S, Fatuzzo F, Montineri A, Mazzola A, L abbate L, Nunnari G, Bronte F, Di Marco V, Craxì A, Cammà C. Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C. Am J Gastroenterol 2011; 106: 2112-2120 [PMID: 21971536 DOI: 10.1038/ajg.2011.341] 145 Motosugi U, Ichikawa T, Niitsuma Y, Araki T. Acoustic radiation force impulse elastography of the liver: can fat deposition in the liver affect the measurement of liver stiffness? Jpn J Radiol 2011; 29: 639-643 [PMID: 21956369 DOI: 10.1007/ s11604-011-0607-5] 146 Muller M, Gennisson JL, Deffieux T, Tanter M, Fink M. Quantitative viscoelasticity mapping of human liver using supersonic shear imaging: preliminary in vivo feasibility study. Ultrasound Med Biol 2009; 35: 219-229 [PMID: 19081665 DOI: 10.1016/j.ultrasmedbio.2008.08.018] 147 Bavu E, Gennisson JL, Couade M, Bercoff J, Mallet V, Fink M, Badel A, Vallet-Pichard A, Nalpas B, Tanter M, Pol S. Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients. Ultrasound Med Biol 2011; 37: 1361-1373 [PMID: 21775051 DOI: 10.1016/j.ultrasmedbio.2011.05.016] 148 Nedredal GI, Yin M, McKenzie T, Lillegard J, Luebke- Wheeler J, Talwalkar J, Ehman R, Nyberg SL. Portal hypertension correlates with splenic stiffness as measured with MR elastography. J Magn Reson Imaging 2011; 34: 79-87 [PMID: 21608066 DOI: 10.1002/jmri.22610] P- Reviewers: Senzolo M, Yoshida H S- Editor: Ma YJ L- Editor: A E- Editor: Zhang DN 459 January 14, 2014 Volume 20 Issue 2

Published by Baishideng Publishing Group Co., Limited Flat C, 23/F., Lucky Plaza, 315-321 Lockhart Road, Wan Chai, Hong Kong, China Fax: +852-65557188 Telephone: +852-31779906 E-mail: bpgoffice@wjgnet.com http://www.wjgnet.com I S S N 1 0 0 7-9 3 2 7 0 2 9 7 7 1 0 07 9 3 2 0 45 2014 Baishideng Publishing Group Co., Limited. All rights reserved.