Central Corneal Thickness and its Association with Ocular Parameters

Similar documents
MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer

International Journal of Health Sciences and Research ISSN:

Correlating central corneal thickness and intraocular pressure in ocular hypertension and glaucoma

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

INTRODUCTION MIKLOS SCHNEIDER 1, GABOR BORGULYA 2, ANDRAS SERES 1, ZOLTAN Z. NAGY 1, JANOS NEMETH 1

INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany

Central corneal thickness (CCT) measurement is a critical

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma

CLINICAL STUDY. AC-M Wong, C-C Wong, NS-Y Yuen and S-P Hui

Correspondence should be addressed to Fusako Fujimura;

Changes in Central Corneal Thickness over Time

Central corneal thickness and vascular risk factors in normal tension glaucoma

Cataract Surgery in the Patient with a History of LASIK or PRK

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a

도시초등학교 4 학년의굴절이상과안계측치변화

RECENT ADVANCES IN ANTERIOR SEGMENT IMAGING OF THE EYE. by Eszter Szalai, M.D. Supervisor: László Módis, M.D., Ph.D.

9/25/2017 CASE. 67 years old On 2 topical meds since 3 years. Rx: +3.0 RE LE

Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria

Interpretation of corneal tomography

Diabetes, Hyperglycemia, and Central Corneal Thickness

Management of Angle Closure Glaucoma Hospital Authority Convention 18 May 2015

Interest in central corneal thickness (CCT) and glaucoma was. Central Corneal Thickness and Glaucoma in East Asian People.

Ocular Rigidity Evaluation After Photorefractive Keratectomy: An Experimental Study

Accuracy and Repeatability of a New Portable Ultrasound Pachymeter

Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow

Central corneal thickness determined with optical coherence tomography in various types of glaucoma

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page

Central corneal thickness and normal tension glaucoma: A cross-sectional study

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS

Given that applanation tonometry estimates the intraocular

Glaucoma: Diagnostic Modalities

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy

Glaucoma is the leading cause of irreversible blindness in

Trabeculectomy is an effective method for lowering

Central Corneal Thickness in Primary Angle Closure and Open Angle Glaucoma

Paraxial Schematic Eye Models for 7- and 14-Year-Old Chinese Children

FEP Medical Policy Manual

Myopia and Glaucoma. Kazuhisa Sugiyama Nagahisa Yoshimura Editors

Ocular Biometric Measurements In Emmetropic And Myopic Malaysian Children - A Population-Based Study

NIH Public Access Author Manuscript Cornea. Author manuscript; available in PMC 2014 May 29.

Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis

Sheldon Herzig MD, FRCSC Herzig Eye Institute Toronto, Ontario

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

Myopia affects 1.6 billion people worldwide and 2.5 billion

Risk Factors for Open-Angle Glaucoma in a Japanese Population

INTRODUCTION J. DAWCZYNSKI, E. KOENIGSDOERFFER, R. AUGSTEN, J. STROBEL. Department of Ophthalmology, University Hospital Jena, Jena - Germany

Corneal densitometry using Pentacam based scheimpflug imaging system: Indian rural population

Corporate Medical Policy

Intro to Glaucoma/2006

December 2016, Volume: 8, Issue: 12, Pages: , DOI:

STUDY OF EFFECTIVENESS OF LENS EXTRACTION AND PCIOL IMPLANTATION IN PRIMARY ANGLE CLOSURE GLAUCOMA Sudhakar Rao P 1, K. Revathy 2, T.

Thickness Changes in the Fovea and Peripapillary Retinal Nerve Fiber Layer Depend on the Degree of Myopia

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Partial Coherence Interferometry as a Technique to Measure the Axial Length of the Eye Archived Medical Policy

CLINICAL SCIENCES. Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma

NIIOS. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece VASILIS S.

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

Relationship between central corneal thickness and parameters of optic nerve head topography in healthy subjects

Structural changes of the anterior chamber following cataract surgery during infancy

Scanning Laser Tomography to Evaluate Optic Discs of Normal Eyes

True IOP No Doubt Facts and Figures Figures. Ziemer Ophthalmic Systems AG a Ziemer Group Company Allmendstrasse 11 CH-2562 Port, Switzerland

Bilateral Microphthalmos Associated with Papillomacular Fold, Severe Hyperopia and Steep Cornea

Laser in situ keratomileusis (LASIK) has proven to be

CENTRAL CORNEAL THICKNESS STUDY CCTS

Optical coherence tomography (OCT) is a new noninvasive

The Role of the RNFL in the Diagnosis of Glaucoma

The Association of Central corneal thickness with Intra-ocular Pressure and Refractive Error in a Nigerian Population

IMPLANTATION OF AN INTRAOCUlar

Accuracy of Biometry for Intraocular Lens Implantation Using the New Partial Coherence Interferometer, AL-scan

M yopia is a growing public health problem with visual,

Pearls for the Refractive Technician Fadiah Alkhawaldeh, IMBA, COT, ROUB

Gender and wavefront higher order aberrations: Do the genders see the world differently?

Increased iris thickness and association with primary angle closure glaucoma

BY MICHAEL W. BELIN, MD

CLASS-y Laser Treats Glaucoma

Populations Interventions Comparators Outcomes Individuals: Who are being evaluated for angleclosure

Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma

Ever since the recognition that certain forms of blindness. Central corneal thickness, tonometry, and glaucoma risk a guide for the perplexed

Anterior segment imaging

Investigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure

Publication list of Dr. Alfred T S Leung

Morphological Study of Corneal Endothelium and Corneal Thickness in Pseudoexfoliation Syndrome

Comparison of Corneal Thickness with Online Optical Coherence Pachymetry and Ultrasound Pachymeter

CENTRAL CORNEAL THICKNESS; COMPARISON OF CENTRAL CORNEAL THICKNESS MEASUREMENTS BY PENTACAM AND ULTRASOUND PACHYMETRY, IN MYOPIC AND KERATOCONUS EYES.

Impact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients

3/23/2016. Diagnostic Services Taylor Pannell CRA, OCT-C. Services Available. Important info for the Tech to know. Visual Fields

Biometry and intraocular lens power calculation Alexander C. Lee, Mujtaba A. Qazi and Jay S. Pepose

4/06/2013. Medication Observation POAG. Proportion. Native American 0.1% 0.4%

Refractive Surgery Dilemma

Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Efficacy of latanoprost in management of chronic angle closure glaucoma. Kumar S 1, Malik A 2 Singh M 3, Sood S 4. Abstract

Recent concerns regarding the depth of tissue ablation with

Transcription:

Central Corneal Thickness and its Association with Ocular Parameters Authors: An-Fei Li 1,2 Mei-Ju Chen 1,2 Affiliations: 1 Department of Ophthalmology, Taipei Veterans General Hospital 2 National Yang-Ming University, School of Medicine Financial support and commercial relationships: none Correspondence to: Dr. Mei-Ju Chen Department of Ophthalmology, Taipei Veterans General Hospital, 201, Section 2, Shih-Pai Road, Taipei 112, Taiwan, R.O.C. Tel: +886-2-2875-7325 Fax: +886-2-2875-7133 E-mail: mj_chen@vghtpe.gov.tw Abstract Central corneal thickness (CCT) is an important indicator of cornea health. CCT is helpful to ensure sufficient corneal thickness for laser ablation on the era of laser refractive surgery. There has been increased interest in CCT because of its influence on intraocular pressure (IOP) measurement. CCT can affect the accuracy of IOP measurement for the diagnosis and management of glaucoma. Glaucoma is a progressive optic neuropathy with irreversible visual field change. Risk factors include age, race, high IOP and myopia. Myopic eyes are characterized with greater refractive error, flatter corneal curvature and longer axial length. Controversy remains regarding whether the impact of CCT on glaucoma is due to its effects on IOP measurement, or may be due to its associated biomechanical and structural changes. Here, we will review the relationship between CCT and ocular parameters such as refractive error, corneal curvature and axial length. Key Words: axial length, central corneal thickness, corneal curvature, glaucoma, myopia, refractive error

1. Introduction Central corneal thickness (CCT) is a valuable indicator of cornea status and is useful for the diagnosis and management of several corneal diseases, including corneal edema caused by different endothelial disorders and contact lens wearing (Rio-Cristobal et al. 2014). For eyes undergoing laser refractive surgery, CCT is helpful to ensure sufficient corneal thickness for laser ablation and to determine minimum stroma beneath the flap to prevent corneal ectasia (Chakrabarti et al. 2001). It is essential to measure CCT when evaluating patients of glaucoma suspect. Glaucoma is a progressive optic neuropathy with a risk factor for high intraocular pressure (IOP). CCT has long been known to affect the accuracy of IOP measurement. Previous studies have shown a positive correlation between CCT and IOP measured by applanation, which causes overestimation of true IOP in thicker corneas and the converse in thinner ones (Damji et al. 2003). A difference of the 10% on the CCT could result in a 3.4 ± 0.9 mmhg variation in IOP measurement (Doughty et al. 2000). It has been demonstrated that CCT is greater in patients with ocular hypertension compared to general population (Singh et al. 2001). A thin CCT is a risk factor for glaucoma (Gordon et al. 2002, Wang et al. 2014) and has been identified as a predictor of glaucoma progression (Leske et al. 2007, Miglior et al. 2007). In addition, myopic eyes are associated with increased risk for glaucoma (Mitchell et al. 1999). Eyes with more myopic refractive error tend to have greater axial lengths and flatter corneal curvatures (Goss et al. 1997, Chen et al. 2009). The eyeball elongates (Lin et al. 1999) with scleral thinning (Funata & Tokoro 1990) in the development of myopia. However, there is no general consensus with respect to how CCT varies with axial length, Page 2

refractive error and corneal curvature. Therefore, we aim to review the relationship between CCT and other associated ocular parameters. 2. CCT Measurements Ultrasound pachymetry is the most common method to evaluate CCT (Figure 1). Figure 1. Ultrasound pachymeter The advantages consist of ease of use, reliability and reasonable cost. When performing this technique, patients need to receive topical anesthesia because of the direct contact of the probe with the cornea. To place the ultrasound probe perpendicular to the cornea may also cause difficult repeatability. Several newer technologies have demonstrated better repeatability and reproducibility; including optical coherence tomography (Martin et al. 2007) (Figure 2), scanning slit topography (Martin et al. 2009) (Figure 3), rotating Scheimpflug camera (Bourges et al. 2009) and Scheimpflug imaging system (Oliveira et al. 2011). Page 3

Figure 2. Printout of CCT measurement by anterior segment optical coherence tomography Figure 3. Printout of CCT measurement by scanning slit topography Page 4

However, the ultrasound pachymetry technique remains the gold standard for corneal thickness assessment due to its fast and reliable measurement at low cost. Compared to the ultrasound pachymetry, optical coherence tomography and the scanning slit topography measurements tend to underestimate the corneal thickness in the previous literature (Thomas et al. 2006, Cheng et al. 2008). 3. Normal CCT values CCT varies between different ethnic groups. In Asia, Hong Kong Chinese have the greatest CCT of 574.5 μm (Cho & Lam 1999), followed by 556.2 μm of Chinese in the Beijing Eye Study (Zhang et al. 2008), 554 μm of Taiwanese Chinese (Chen et al. 2009), 541.2 μm of Singaporean Malays (Wu et al. 2011), 521 μm of Japanese (Tomidokoro et al. 2007) and 511.4 μm of South Indians a mean CCT of 579 μm (Brandt et al. 2001), while a mean CCT of 558.5 μm is noted in another Caucasian population (Wang et al. 2014). Caucasians usually have thicker corneas than that of Asians. Blacks have thinner corneas of 521 μm than other ethnic groups (Aghaian et al. 2004). Hispanics (550.4 μm, Wang et al. 2014) have CCT intermediate between Blacks and Caucasians. Glaucoma is a progressive optic neuropathy with several risk factors including Black race or Hispanic ethnicity. Variation in CCT explained almost 30% of the increased risk of glaucoma seen among Blacks and Hispanics compared to Caucasians, with adjustment for differences in IOP (Wang et al. 2014). It may be explained by some genetic risk factors for glaucoma co-inherited with CCT (Wang et al. 2014). CCT appears to be an important mediator of the relationship between glaucoma and race. (Vijaya et al. 2010). Caucasians in the ocular hypertension treatment study have Page 5

4. CCT and associated ocular parameters 4.1 CCT and refractive error The relationship between CCT and refractive error is controversial across earlier studies. For myopic populations, thinner corneas were reported in 216 young adults with an averaged refractive error of -4.17 diopters (Chang et al. 2001), whereas no correlation with the degree of myopia was found in 714 Singaporean Chinese with a mean refractive error of -5.3 diopters (Fam et al. 2006). For normal populations, a significant correlation between CCT and refraction was demonstrated in 3021 Japanese (Suzuki et al. 2005). In contrast, other studies failed to reveal a significant correlation between CCT and refraction in 4439 Chinese (Zhang et al. 2008), 500 Taiwanese Chinese (Chen et al. 2009), 652 Singaporean schoolchildren (Tong et al. 2004) and 3239 Singaporean Malays (Su et al. 2009), respectively. It seems that CCT was not correlated with refractive error in most of the studies mentioned above. 4.2 CCT and corneal curvature The relationship between CCT and corneal curvature was investigated in several earlier studies. CCT was positively correlated with corneal curvature in 1976 Americans (Shimmyo et al. 2003), 2868 Japanese (Sawada et al. 2008), 1190 Chinese (Wang et al. 2016) and 4711 Indians (Nangia et al. 2010), respectively. A weak correlation between CCT and corneal curvature was also demonstrated in other studies (Tong et al. 2004, Suzuki et al. 2005). In contrast, no correlation between CCT and corneal curvature was reported in 925 Caucasians (Eyesteinsson et al. 2002). Similar findings were also found in several investigations (Cho & Lam 1999, Chang et al. 2001, Fam et al. 2006, Chen et al. 2009). Because physiological variation in corneal curvature and index of refraction rarely influence CCT measurements (Olsen & Ehlers 1984), different methodologies might explain the Page 6

discrepancies in previous studies. The corneal curvature theoretically influences the oblique section of the cornea by using a split prism for optical pachymetry. Investigators attributed their correlation between CCT and corneal curvature to the specular microscopic device they used (Suzuki et al. 2005). 4.3 CCT and axial length There appears to be no consensus concerning the relationship between CCT and axial length. Significantly thinner CCT was noted in eyeballs with greater axial length (Chang et al 2001, Su et al. 2009). It was proposed that as the surface area of the cornea increased, the corneal stroma became thinner. Reduced corneal thickness could be expected as the eyeball elongated axially. However, no association between CCT and axial length was found in different population studied (Shimmyo & Orloff 2005, Oliveira et al. 2006, Chen et al. 2009, Nangia et al. 2010). During the development of myopia, the eyeball elongates and the sclera thins, with greater involvement of the posterior segment (Celorio & Pruett 1991). Although collagen is the main component of the sclera and cornea, glycosaminoglycan and elastin content, hydration and predominant collagen type may vary between them (McBrien & Gentle 2003). CCT may be unaffected by the scleral thinning that occurs during eyeball elongation. 5. Conclusion There was no consensus with respect to how CCT varied with refractive error, corneal curvature and axial length. The results may be affected by participants from different ethnic background and clinical setting. In addition, the methods used to measure ocular parameters may not have been uniform in previous studies. For example, ultrasound pachymetry vs. optical methods to measure the CCT and IOLMaster vs. A-scan to measure axial length were performed in these studies. These differences would confound the results of association between CCT and Page 7

ocular parameters, accounting for the lack of agreement demonstrated in the various studies. In summary, there is no obvious evidence suggesting association between CCT and other ocular parameter. CCT appears to be an independent biological corneal curvature and axial length. In the future, more studies may determine the physiologic mechanisms by which variation in CCT between individuals and its association with other ocular parameters. parameter unrelated to refractive error, Page 8

References Aghaian E, Choe JE, Lin S, et al. Central corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinic. Ophthalmology. 2004; 111(12):2211 2219. Bourges JL, Alfonsi N, Laliberté JF, et al. Average 3-dimensional models for the comparison of Orbscan II and Pentacam pachymetry maps in normal corneas. Ophthalmology. 2009; 116(11):2064 2071. Brandt JD, Beiser JA, Kass MA, et al. Central corneal thickness in the ocular hypertension treatment study (OHTS). Ophthalmology. 2001; 108(10):1779 1788. Celorio JM, Pruett RC. Prevalence of lattice degeneration and its relation to axial length in axial myopia. Am J Ophthalmol. 1991; 111(1):20 23. Chakrabarti HS, Craig JP, Brahma A, et Orbscan slit-scanning topography in normal and post-lasik eyes. J Cataract Refract Surg. 2001; 27(11):1823 1828. Chang SW, Tsai IL, Hu FR, et al. The cornea in young myopic adults. Br J Ophthalmol. 2001; 85(8):961 970. Chen MJ, Liu YT, Tsai CC, et al. Relationship between central corneal thickness, refractive error, corneal curvature, anterior chamber depth and axial length. J Chin Med Assoc. 2009; 72(3):133 137. Cheng AC, Rao SK, Lau S, et al. Central corneal thickness measurements by ultrasound, Orbscan II, and Visante OCT after LASIK for myopia. J Refrac Surg. 2008; 24(4):361 365. Cho P, Lam C. Factors affecting the central corneal thickness of Hong Kong-Chinese. Curr Eye Res. 1999; 18(5):368 374. al. Comparison of corneal thickness measurements using ultrasound and Page 9

Damji KF, Muni RH, Munger RM. Influence of corneal variables on accuracy of intraocular pressure measurement. J Glaucoma. 2003; 12(1): 69 80. Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000; 44(5):367 408. Eyesteinsson T, Jonasson F, Sasaki H, et al. Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study. Acta Ophthalmol Scand. 2002; 80(1):11 15. Fam HB, How AC, Baskaran M, Lim KY, et al. Central corneal thickness and its relationship to myopia in Chinese adults. Br J Ophthalmol. 2006; 90(12):1451 1453. Funata M, Tokoro T. Scleral change in experimentally myopic monkeys. Graefes Arch Clin Exp Ophthalmol. 1990; 228(2):174 179. Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002; 120(2):714 720. Goss DA, Van Veen HG, Rainey BB, Feng B. Ocular components measured by keratometry, phakometry, and ultrasonography in emmetropic and myopic optometry students. Optom Vis Sci. 1997; 74(7):489 495. Leske MC, Heijl A, Hyman L, et al. Predictors of long-term progression in the early manifest glaucoma trial. Ophthalmology. 2007; 114(11):1965 1972. Lin LL, Shih YF, Tsai CB, et al. Epidemiologic study of ocular refraction among schoolchildren in Page 10

Taiwan in 1995. Optom Vis Sci. 1999; 76(5):275 281. Martin R, de Juan V, Rodríguez G, et al. Measurement of corneal swelling variations without removal of the contact lens during extended wear. Invest Ophthalmol Vis Sci. 2007; 48(7):3043 3050. Martin R, de Juan V, Rodríguez G, et al. Contact lens-induced corneal peripheral swelling: Orbscan repeatability. Optom Vis Sci. 2009; 86(4):340 349. McBrien NA, Gentle A. Role of the sclera in the development and pathological complications of myopia. Prog Retin Eye Res. 2003; 22(3):307 338. Miglior S, Pfeiffer N, Torri V, et al. Predictive factors for open-angle glaucoma among patients with ocular hypertension in the European Glaucoma Prevention Study. Ophthalmology. 2007; 114(1):3 9. Mitchell P, Hourihan F, Sandbach J, glaucoma and myopia: the Blue Mountains Eye Study. Ophthalmology. 1999; 106(10):2010 2015. Nangia V, Jonas JB, Sinha A, et al. Central corneal thickness and its association with ocular and general parameters in Indians: the Central India Eye and Medical Study. Ophthalmology. 2010; 117(7):705 710. Oliveira C, Tello C, Liebmann J, Ritch R. Central corneal thickness is not related to anterior scleral thickness or axial length. J Glaucom. 2006; 15(3):190 194. Oliveira CM, Ribeiro C, Franco S. Corneal imaging with slit-scanning and Scheimpflug imaging techniques. Clin Exp Optom. 2011; 94(1):33 42. Olsen T, Ehlers N. The thickness of the human cornea as determined by a specular method. Acta Ophthalmol (Copenh). 1984; 62(6):859 871. Wang JJ. The relationship between Page 11

Rio-Cristobal A, Martin R. Corneal assessment technologies: current status. Surv Ophthalmol. 2014; 59(6):599 614. Sawada A, Tomidokoro A, Araie M, et al. Refractive errors in an elderly Japanese population: the Tajimi study. Ophthalmology. 2008; 115(2):363 370. Shimmyo M, Orloff PN. Cornea thickness and axial length. Am J Ophthalmol. 2005; 139(3):553 554. Shimmyo M, Ross AJ, Moy AJ, Mostafavi B. Intraocular pressure, Goldmann applanation tension, cornea thickness, and corneal curvature in Caucasians, Asians, Hispanics and African Americans. Am J Ophthalmol. 2003; 136(4):603 611. Singh RP, Goldberg I, Graham SL, et al. Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma. Su DH, Wong TY, Foster PJ, et al. Central corneal thickness and its associations with ocular and systemic factors: the Singapore Malay Eye Study. Am J Ophthalmol. 2009; 147(4):709 716. Suzuki S, Suzuki Y, Iwase A, et al. Corneal thickness in an ophthalmologically normal Japanese population. Ophthalmology. 2005; 112(8):1327 1336. Thomas J, Wang J, Rollons AM, et al. Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method. J Refrac Surg. 2006; 22(7):671 678. Tomidokoro A, Araie M, Iwase A. Corneal Thickness and Relating Factors in a Population-Based Study in Japan: The Tajimi Study. Am J Ophthalmol. 2007; 144(1):152 154. Tong L, Saw SM, Siak JK, et al. Corneal thickness determination and correlates in Singaporean 2001; 10(3):206 210. Page 12

schoolchildren. Invest Ophthalmol Vis Sci. 2004; 45(11):4004 4009. multiethnic population. J Glaucoma. 2014; 23(9):606 612. Vijaya L, George R, Arvind H, et al. Central corneal thickness in adult south Indians: the Chennai Glaucoma Study. Ophthalmology. 2010; 117(4):700 704. Wang Q, Liu W, Wu Y, et al. corneal thickness and its relationship to ocular parameters in young adult myopic eyes. Clin Exp Optom. 2016 Oct 18. Wang SY, Melles R, Lin SC. The impact of central corneal thickness on the Wu RY, Zheng YF, Wong TY, et al. Relationship of central corneal thickness with optic disc parameters: the Singapore Malay Eye Study. Invest Ophthalmol Vis Sci. 2011; 52(3):1320 1324. Zhang H, Xu L, Chen C, Jonas JB. Central corneal thickness in adult Chinese. Association with ocular and general parameters. The Beijing Eye Study. Graefes Arch Clin Exp Ophthalmol. 2008; 246(4):587 592. risk for glaucoma in a large Page 13