Device Technical File

Similar documents
INSTRUCTIONS FOR USE AND CARE

Essentials of. Dental Assisting. Edition 6. Debbie S. Robinson Doni L. Bird

IFURH0017.V04 NOV2017 INSTRUCTIONS FOR USE CLINICAL PROCEDURE

Stainless Steel Crowns

M. Molitor REMOVAL OF ORTHODONTIC BANDS AND CEMENT REMOVAL WITH A HAND INSTRUMENT

Efficient Bonding Protocol for the Insignia Custom Bracket System

POLYDENTIA S QUICKMAT DELUXE MATRIX SYSTEM FOR PERFECT CLASS II RESTORATIONS

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

CURVES. Anatomically Adaptable IPR strips. Brochure Instructions for use Processing instructions

TOOTH ISOLATION. the Rubber Dam. Dr. Ahmed Al-Jobory

For the Perfect Class V and All Cervical Area Gingival Margins when Placing Direct Composites, Create an Injection Molding Matrix

Syllabus for International Dental Assistants. Prepare and maintain the dental surgery, instruments, and equipment for clinical dental procedures

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Perfect contacts with zero flash. 3D XR delivers outstanding performance even on difficult dentition.

Indications The selection of amalgam as a restorative material for class V cavity should involve the following considerations:

Clinical report. Drs Paul and Alexandre MIARA and F. CONNOLLY COMPOSITE POSTERIOR FILLINGS. How to control. layering? 8 - Dentoscope n 124

THE. Curve THE CURVE STRIPPING TOOL

The fitting process of SomnoGuard AP. Hints to complement the user instructions

TASKS. 2. Apply a disclosing agent to make the plaque visible.

insafe System - Directions for Use

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Transbond PLUS Color Change Adhesive Lunch and Learn

Restorative. Design By Dentists. By DIRECTA

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

INSTRUCTION MANUAL. Orascoptic 3225 Deming Way, Suite 190 Middleton, WI USA T:

The fitting process of SomnoGuard

ÆLITE Composites. Bisco. Instructions for Use. Light- Cured. U.S. Patent: 6,709,271

Advancing the Art of Freehand Cosmetic Contouring

ProUltra ULTRASONIC SURGICAL TIPS

D.T. LIGHT-POST. Bisco. Instructions for Use. Radiopaque Translucent Fiber Post System. Double Taper

ORTHODONTIC BANDING AND CEMENTATION. Materials

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Press Release. Press Contact. The concept for Class II restoration Delicate preparation, rapid procedure and reliable results

BOCL-01: Bonding Materials Checklist

50 Shades of Teflon Part 1

The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau

RESINOMER Dual- Bisco. Instructions for Use. Cured Amalgam Bonding/Luting System

ProSomnus MicrO 2 Sleep and Snore Device

Filtek LS Low Shrink Posterior Restorative System Case 1: Cusp build-up

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE

Incognito Appliance System Bonding Protocols Step-by-Step Procedures

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Instructions for Use io-flex Probe

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

ProSomnus MicrO 2 Sleep and Snore Device

Brochure. Ivory Rubber Dam Clamps. The complete system for tooth isolation. Giving a hand to oral health.

IOS & The Sirona Connect System Clinician Procedure

ProUltra Ultrasonic Non Surgical Endo Tips

Initial placement 24FR Pull PEG kit REORDER NO:

Initial placement 20FR Guidewire PEG kit REORDER NO:

Calibra. Cements. The Simple Choice for Easy Cleanup

Quality. Elegance. Innovation.

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

1) INDICATIONS FOR USE These products have to be used only in hospital environments, clinics or dental offices by qualified dental personnel.

DUO-LINK UNIVERSAL KIT

Amalgam restoration of posterior proximal cavities with deep and concave gingival outlines

MemRx Orthodontic Appliances

Midwest E Motor. Directions For Use. Doc. No

ORTHODONTIC INSTRUMENTS

SELF LIGATING BRACKETS. 1. Commercial name: EasyClip EasyClip+ Lotus Self-ligating single buccal tubes

Archwire Insertion and Disengagement Instruments Technique Guide

Bisco UNIVERSAL PRIMER

OPERATING INSTRUCTIONS. Orascoptic DK

UNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Chapter 5: Checking and Maintaining Ultrasound Equipment

D.T. LIGHT-POST. Instructions for Use. Bisco 0459 D.T. LIGHT-POST X-RO. Radiopaque Translucent Fiber Post System ILLUSION

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

Radiographic Policy *ALL RADIOGRAPHS ARE TAKEN FOR DIAGNOSTIC PURPOSES ONLY

The Sof-Lex Finishing and Polishing System 3ESPE

values is of great interest.

Invisible Retainer with Multi-Tooth Pontic Fabrication Technique (Single-Tooth Pontic Procedure also available)

ASSIGNMENT 16. Book Assignment: Operative Dentistry, pages 16-1 to 16-33

MX SELECT OWNER S MANUAL. Revolutionising Strength Training REGISTER YOUR PRODUCT AT MXSelect. MX_Select.

M6-C Artificial Cervical Disc Surgical Instruments

Technique Guide. Rapid IMF Device. Temporary mandibular fixation device.

LOCATOR ROOT ATTACHMENT SYSTEM

Product Information Packet Table of Contents. Introduction. Pit Shark Attachment. Attachment for Pendulum Rack. Introduction...

A Step-by-Step Approach to

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

illustrated technique guide

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

A SIMPLIFIED INSTRUMENTATION APPROACH TO ULTRASONIC DEBRIDEMENT Hands On Workshop

Dental Chairside

Restorative Resin Cement for Bonding and Masking Tetracycline and Dark Stained Teeth for All Veneers

Velocity Orthopedics Instrument Cleaning and Sterilization

Patient/Carer instructions for the administration of Subcutaneous Cytarabine

Desara TV and Desara Blue TV

Restoring Straumann implants. with Locator abutments.

LOCATOR F-Tx SEATING AND REMOVAL TOOL PROCEDURES ADDENDUM

BLOOD COLLECTION GUIDELINES

Scope This policy applies to all personnel and departments that clean, prepare and/or sterilize items intended for patient care use.

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

Invisible Retainer with Single-Tooth Pontic Fabrication Technique (Multi-Tooth Pontic Procedure also available)

SelectTech 3.1 Bench Assembly / Owner s Manual

Brochure. Ivory Rubber Dam Clamps. The complete system for tooth isolation. Giving a hand to oral health.

FS MTS. Micro Periodontal Tissue Scissors

GLOVES. Getting a grip on infection control. a complete guide for every exposure level

GLUMA Comfort + Desensitizer

Transcription:

Device Technical File ContactPro Matrix System Instructions for Use 1.0 Product Description A. For placement of restorations in the posterior area of the oral cavity, the Microbrush ContactPro Sectional Matrix System includes: 1. ContactPro sectional matrix ring 2. Smartband matrix bands (coated or plain) 3. Wedges 4. Matrix ring forceps 5. Matrix band tweezers B. Matrix bands are suitable for use with all posterior restorative materials. C. Either one matrix ring may be used for the restoration, or multiple rings may be stacked together for performing MODs and multiple-tooth restorations. D. The advantages of the Microbrush ContactPro Sectional Matrix System include: 1. Consistent results with the ring made out of exclusively engineered memory metal 2. Easy to open with a strong grip around the tooth 3. Stackable 4. Wide visibility 5. Secure fit along the gingival margin for better overall adaptation 6. Adaptable tips 7. Better access for light curing 8. More comfort for the patient and practitioner. 1.1 System Components A. Sectional Matrix Ring 1. The Microbrush ContactPro matrix Ring is for use in the posterior region of the oral cavity. 2. It can be used either as a single ring or multiple rings stacked together for performing MODs and multiple-tooth restorations.

Page 2 of 8 B. Matrix Bands 1. The coated versions of the Microbrush Smartband matrix bands come in a variety of sizes, each with its own identifying color: a. 3.5 mm (White) b. 4.5 mm (Green) c. 5.5 mm (Blue) d. 6.5 mm (Red) e. 7.5 mm (Gray) 2. Uncoated sizes are the same as the coated sizes and have a natural silver appearance. 3. Microbrush Smartband matrix bands are suitable for use with all posterior restorative materials. C. Wood Wedges 1. Sizes: a. Extra small (Pink) b. Small (Blue) c. Medium (Green) d. Large (Yellow) 2. The wedges are anatomically shaped for optimum adaptation along the tooth cervical margin. 1.2 Materials A. Sectional matrix ring: nickel-titanium and silicone B. Matrix bands: polished stainless steel with or without non-stick coating C. Wedges: maple wood D. Matrix ring forceps: stainless steel E. Matrix band tweezers: stainless steel 1.3 Indications A. The Microbrush ContactPro Sectional Matrix System is indicated for Class II restorations to facilitate the direct placement of restorative materials. 1.4 Contraindications A. None known 2.0 General Safety Notes A. Be aware of the following safety notes in other chapters of these directions for use.

Page 3 of 8 B. Always visit www.microbrush.com for the latest Instructions for Use. Safety Alert Symbol This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury. 2.1 Warnings A. The Microbrush ContactPro Sectional Matrix System consists of small parts. As with all intra-oral devices, care must be exercised to ensure stable handling and placement. 1. Wear applicable protective eyewear and gloves. 2. Placement of a rubber dental dam is strongly recommended to prevent the potential for inhalation or ingestion of such parts. 3. To avoid inadvertent swallowing or aspiration of the ring should it unexpectedly come loose from its seated position, tying the ring to a previously placed rubber dam clamp with dental floss is recommended. 4. Aspiration: If aspiration of matrix band, wedge or retaining ring occurs, seek immediate medical attention. 5. Ingestion: If accidental swallowing occurs, encourage patient to seek medical assistance to locate swallowed part. If nausea or illness develops, seek medical attention immediately. 6. Laceration: Handling matrix bands with gloved hands and/or cotton dressing forceps or similar instrument is recommended. In the unlikely event a clean matrix band causes a skin laceration, employ usual first aid measures. Discard and properly dispose of matrix band. 7. Used matrix bands and accessories are to be considered contaminated. Follow proper exposure control plans. a. In the event of an accidental exposure, follow recommended postexposure procedures. b. Following the use of the Microbrush ContactPro Sectional Matrix System, proper handling and disposal techniques are required. c. Use precautions when handling or disposing contaminated items. B. Care should be taken to have good control of any instrument during use in order to protect patients from injury. 2.2 Precautions A. This product is intended to be used only as specifically outlined in the Instructions for Use. Any use of this product inconsistent with the Instructions for Use is at the discretion and sole responsibility of the practitioner. B. Care must be taken when placing the retaining ring. Ensure ring is fully seated in forceps.

Page 4 of 8 C. Excessive pressure on matrix, wedge, or retaining ring in an apical direction may result in injury to periodontal tissues. D. This product is provided in a non-sterile condition. E. Devices marked single use on the label are intended for single use only. Discard after use. Do not reuse in other patients in order to prevent crosscontamination. F. It is recommended that the tools supplied with the Microbrush ContactPro Sectional Matrix System be used with the matrix rings and bands to reduce chances of injury. 2.3 Adverse Reactions A. Product misuse may cause failure resulting in respiratory, digestive, eye, skin, or mucosa injury. (See Sections 1.4 Contraindications, 2.1 Warnings, and 2.2 Precautions) B. Failure to properly employ accepted handling and disposal techniques may present biohazard. (See Sections 2.1 Warnings and 2.2 Precautions) 2.4 Pre-operative Sterilization A. Matrix bands are supplied non-sterile and are for single use only. Prior to clinical use, they should be cleaned with a mild detergent and then steam autoclaved one time at 121 C for 15 minutes, followed by a 25 minute air drying time. B. The matrix ring, forceps, and tweezers are supplied non-sterile, and they should be steam autoclaved prior to first and each subsequent use. 3.0 Instructions 3.1 Isolation of the Area A. Isolation of the area helps to prevent contamination from blood and saliva. B. As with many dental procedures, aspiration of small parts is a valid concern. 1. Placement of a rubber dental dam is mandatory to prevent the potential for inhalation or ingestion of such parts. 2. To avoid inadvertent swallowing or aspiration of the ring (should it unexpectedly come loose from its seated position), tying the ring to a previously placed rubber dam clamp with dental floss is recommended. C. Pre-Operative Placement of Ring for Separation (Optional) 1. To effectively use a contoured matrix band, there must be enough interproximal space to position the matrix without force or distortion.

Page 5 of 8 2. When placed prior to and left on during cavity preparation, the matrix ring creates the interproximal space required for matrix band placement. 3.2 Cavity Preparation A. Complete preparation as usual. B. After preparation is complete, follow the matrix band placement (Step 3.3), wedge placement (Step 3.4) and matrix ring placement (Step 3.5) instructions. 3.3 Matrix Band Placement A. Select a matrix band that most closely approximates the occlusogingival height of the tooth. B. Using Microbrush ContactPro tweezers, grasp the tab at the top-center area of the matrix band. Over-approximate tooth curvature buccolingually by rolling the matrix band with your fingers. This will help keep the band ends from interfering with the ring placement. C. The matrix band should be oriented with the convex edge towards the gingival margin of the tooth, and the tab on top. 1. The matrix band s placement tab may be bent over the adjacent marginal ridge to facilitate restoration marginal ridge contour. 2. Ensure matrix band is apical to preparation margin with no gap. 3.4 Wedge Placement A. For optimal contour, gingival seal, and tooth separation, use Microbrush ContactPro wedges, which are available in 4 sizes ranging from extra small to extra large. B. Keep a finger on the matrix band placement tab to prevent the wedge from dislodging the matrix band during insertion. C. As a high viscosity resin packed into the preparation may displace the matrix band away from the tooth, firmly insert the wedge. 3.5 Matrix Ring Placement A. For secure gripping of the matrix ring tips to the surfaces, dry the teeth thoroughly before placement. B. Grasp the Microbrush ContactPro matrix ring near the tips of the ring with the dedicated matrix ring forceps supplied, being sure the ring rests within the channels on the forceps tips. C. Spread the matrix ring with the forceps only enough to clear tooth height of contour.

Page 6 of 8 1. Do not over-expand the matrix ring. Over-expansion may result in permanent ring deformation. 2. The locking slide on the forceps may be engaged to facilitate carrying and placement of the ring. D. To avoid hitting and possibly dislodging the matrix band when placing the ring, bring the matrix ring down at an angle over the adjacent tooth and then flatten out the ring as you place it into the interproximal space and over the top of the wedge. E. Place the matrix ring with the center of each tine in each interproximal space from buccal to lingual adjacent to the surface to be restored. 1. The direction the ring points, mesially or distally, does not matter. However, it may be easier to place it such that the ring points mesially because that side can be easier to access. 2. The matrix ring needs to sit along the gingiva so that the tips grip the tooth below the height of the tooth contour. F. After aligning the slots on the bottom of the matrix ring tips with the wedge, fit the ring over the wedge. G. With the tips properly positioned interproximally, release the locking slide on the forceps and slowly release the tension on the forceps. H. When the matrix ring is securely seated, release the forceps completely and withdraw them. I. To avoid inadvertent swallowing or aspiration of the ring (should it unexpectedly come loose from its seated position), tying the ring to a previously placed rubber dam clamp with dental floss is recommended. 3.6 Contouring to Adjacent Tooth A. To form proper contours, it is important to push the matrix band firmly into contact with the adjacent tooth in the desired contact area. B. The matrix band s placement tab may be bent over the adjacent marginal ridge to facilitate restoration marginal ridge contour. Small parts under tension 1. Be sure the matrix ring is securely seated in the forceps before introducing into the patient field. 2. Be sure the matrix ring is securely seated apically before withdrawing the forceps.

Page 7 of 8 3.7 Restorative Application A. Use your preferred etching, disinfecting and bonding technique following manufacturer's instructions. B. Apply your preferred restorative material following manufacturer's instructions. Light cure and/or allow material to reach initial set. C. Gross contouring may be accomplished with matrix band in place. 3.8 Removal A. Remove matrix ring using the supplied dedicated matrix ring forceps. B. Remove wedge and matrix band using the supplied matrix band tweezers or similar instrument. 3.9 Finishing A. Finish the contouring. B. Verify the proximal contact. C. Polish the restoration. 4.0 Hygiene 4.1 Cleaning: A. The Microbrush ContactPro ring placement forceps and ring may be cleaned by scrubbing with a disposable towel soaked with hot water and soap or detergent. 4.2 Sterilization: A. The Microbrush ContactPro matrix ring, ring forceps, and band tweezers should be steam autoclaved at 121 C for 15 minutes, followed by air drying for 25 minutes. B. Use of other sterilization procedures or methods is at the discretion and sole responsibility of the practitioner. C. It is not recommended to immerse components into disinfection or cold sterilization solutions. D. Microbrush ContactPro matrix bands and wedges are supplied non-sterile and are for single use only. Sterilize for use by steam autoclaving, 121 C for 15 minutes, followed by air drying for 25 minutes.

Page 8 of 8 4.3 Post Sterilization A. Allow matrix ring, ring forceps, and band tweezers to dry prior to storage. B. The forceps require no additional maintenance and should not be oiled or greased. Disposal of Single-use Components and Sterilization To prevent cross-contamination: 1. Do not reuse matrix bands or wedges in a different patient. 2. Do not attempt to sterilize used matrix bands or wedges. 3. Properly dispose of the used and/or contaminated matrix bands and/or wedges in accordance with local regulations. 5.0 Part identification 5.1 The following numbers should be quoted in all communications with Microbrush International: A. Kit or part number B. Lot number on the package CONTACT: Microbrush International 1376 Cheyenne Ave. Grafton, WI 53024 USA www.microbrush.com customerservice@microbrush.com (866) 866-8698 Young Microbrush LLC dba Emergo Europe Microbrush International Prinsessegracht 20 1376 Cheyenne Ave 2514 AP The Hague Grafton, WI 53024 USA The Netherlands