Left Ventricular Outflow Tract Obstruction Defined by Active Three-Dimensional Echocardiography Using Rotational Transthoracic Acquisition

Similar documents
Case 47 Clinical Presentation

Double outlet right ventricle: navigation of surgeon to chose best treatment strategy

cardiac imaging planes planning basic cardiac & aortic views for MR

Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septa1 Defect Closure

ULTRASOUND OF THE FETAL HEART

Most common fetal cardiac anomalies

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE)

LEFT VENTRICULAR OUTFLOW OBSTRUCTION WITH A VSD: OPTIONS FOR SURGICAL MANAGEMENT

Congenital Heart Disease

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING

Giovanni Di Salvo MD, PhD, FESC Second University of Naples Monaldi Hospital

ISUOG Basic Training. Obtaining & Interpreting Heart Views Correctly Alfred Abuhamad, USA. Basic training. Editable text here

Diagnostic approach to heart disease

Cardiac ultrasound protocols

PROSTHETIC VALVE BOARD REVIEW

Heart and Lungs. LUNG Coronal section demonstrates relationship of pulmonary parenchyma to heart and chest wall.

Atrial Septal Defects

Adult Echocardiography Examination Content Outline

Intro to Bedside Ultrasound. Cardiac Ultrasound

The background of the Cardiac Sonographer Network News masthead is a diagnostic image:

JOINT MEETING 2 Tricuspid club Chairpersons: G. Athanassopoulos, A. Avgeropoulou, M. Khoury, G. Stavridis

ECHOCARDIOGRAPHIC APPROACH TO CONGENITAL HEART DISEASE: THE UNOPERATED ADULT

Doppler-echocardiographic findings in a patient with persisting right ventricular sinusoids

Cardiology Fellowship Manual. Goals & Objectives -Cardiac Imaging- 1 P a g e

Techniques for repair of complete atrioventricular septal

Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Pediatric Echocardiography Examination Content Outline

Transposition of the Great Arteries Preoperative Diagnostic Considerations. John Simpson Evelina Children s Hospital London, UK

HISTORY. Question: What category of heart disease is suggested by this history? CHIEF COMPLAINT: Heart murmur present since early infancy.

14 Valvular Stenosis

Echocardiography in Adult Congenital Heart Disease

Fetal Tetralogy of Fallot

British Society of Echocardiography

Introduction to TEE using Heartworks Echocardiography Simulator

Adult Congenital Heart Disease: What All Echocardiographers Should Know Sharon L. Roble, MD, FACC Echo Hawaii 2016

Data Collected: June 17, Reported: June 30, Survey Dates 05/24/ /07/2010

VMS Quick Reference Guide

PRACTICAL GUIDE TO FETAL ECHOCARDIOGRAPHY IC Huggon and LD Allan

Tissue Doppler Imaging in Congenital Heart Disease

Revealing new insights. irotate electronic rotation and xplane adjustable biplane imaging. Ultrasound cardiology. irotate and xplane

Radiology of the respiratory/cardiac diseases (part 2)

In Vitro Two-Dimensional Echocardiographic Imaging of a Stented Porcine Bioprosthetic Valve: The Bent Strut Artifact

Congenital Heart Defects

TGA Surgical techniques: tips & tricks (Arterial switch operation)

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Heart and Soul Evaluation of the Fetal Heart

"Giancarlo Rastelli Lecture"

Part II: Fundamentals of 3D Echocardiography: Acquisition and Application

Echocardiography in Congenital Heart Disease

An intensive interactive course for 3D echocardiography: is crop till you drop an effective learning strategy?

HISTORY. Question: What type of heart disease is suggested by this history? CHIEF COMPLAINT: Decreasing exercise tolerance.

Cardiac MRI in ACHD What We. ACHD Patients

TEE Outside of the Cardiac OR

Conflict of Interests

echocardiography, three-dimensional echocardiography, three-dimensional reconstruction., ultrasound,

pulmonary valve on, 107 pulmonary valve vegetations on, 113

Breakout Session: Transesophageal Echocardiography

Hypoplastic Left Heart Syndrome: Echocardiographic Assessment

The modified Konno procedure, or subaortic ventriculoplasty,

How to Assess and Treat Obstructive Lesions

INTEGRATING ECHOCARDIOGRAPHY WITH CATHETER INTERVENTIONS FOR CONGENITAL HEART DISEASE. Krishna Kumar SevenHills Hospital, Mumbai, India

Little is known about the degree and time course of

Congenitally Corrected Transposition of the Great Arteries (cctga or l-loop TGA)

aortic regurgitation, vena contracta area, vena contracta width, live three-dimensional echocardiography

Chapter 3.14 Aortic arch interruption

PRACTICAL ECHOCARDIOGRAPHY IN THE ADULT with Doppler and color-doppler flow imaging

December 2018 Tracings

Cases in Adult Congenital Heart Disease

Index. radiologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

가천의대길병원소아심장과최덕영 PA C IVS THE EVALUATION AND PRINCIPLES OF TREATMENT STRATEGY

Making Sense of Cardiac Views and Imaging Characteristics for 13 Congenital Heart Defects (CHDs)

Journal of American Science 2014;10(9) Congenital Heart Disease in Pediatric with Down's Syndrome

Imaging Evaluation of the Ventricular Septum

Pulmonary arteriovenous fistula

ARTIFACTS: THEORY AND ILLUSTRATIVE EXAMPLES

MITRAL STENOSIS. Joanne Cusack

ECHOCARDIOGRAPHY DATA REPORT FORM

Imaging Guide Echocardiography

Systematic approach to Fetal Echocardiography. Objectives. Introduction 11/2/2015

When Does 3D Echo Make A Difference?

Distinguishing Right From Left: A Standardized Technique for Fetal Echocardiography

Aortic arch anomalies Coarctation of the Aorta Interrupted Aortic Arch Echocardiography

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

Left atrial function. Aliakbar Arvandi MD

(Ann Thorac Surg 2008;85:845 53)

Normal TTE/TEE Examinations

Recent technical advances and increasing experience

Transesophageal Echocardiography in Children: An Interactive Session on Common Congenital Cardiac Defects

Coexistence of asymmetric septal hypertrophy and aortic valve disease in adults

ASCeXAM / ReASCE. Practice Board Exam Questions Monday Morning

Cardiac Catheterization Cases Primary Cardiac Diagnoses Facility 12 month period from to PRIMARY DIAGNOSES (one per patient)

Doppler Basic & Hemodynamic Calculations

Atrioventricular Canal (Septal) Defects. Norman H Silverman MD. D Sc (Med),FACC, FAHA

Reoperation for Left Ventricular Outflow Tract Obstruction After Repair of Atrioventricular Septal Defect

Multimodality Imaging of Septal Defects

Anatomy of left ventricular outflow tract'

Fetal Echocardiography and the Routine Obstetric Sonogram

Reverse Doming of the Anterior Mitral Leaflet With Severe Aortic Regurgitation

Department of Cardiology, Heidelberg University, Im Neuenheimer Feld 410, Heidelberg, Germany 2

Transcription:

Left Ventricular Outflow Tract Obstruction Defined by Active Three-Dimensional Echocardiography Using Rotational Transthoracic Acquisition DEREK A. FYFE, M.D., PH.D., ACHI LUDOMIRSKY, M.D.,* SATINDER SANDHU, M.D.,*,** PRADIP K. DHAR, M.D., MICHAEL SILBERBACH, M.D.**, and DAVID J. SAHN, M.D.** South Carolina Children s Heart Center, Medical University of S.C., Charleston, South Carolina; *Department of Pediatrics (Cardiology), University of Michigan, Ann Arbor, Michigan; and **Center for Congenital Heart Disease, Oregon Health Sciences University, Portland, Oregon A rotational data acquisition system was used to create three-dimensional images from thoracic and subxiphoid echocardiographic windows in children with various types of subaortic stenosis. Thirteen patients, ranging in age from 2 days to 17 years, were examined. Subaortic obstruction was caused by a discrete fibrous ridge in six patients, hypertrophic cardiomyopathy in two patients, subaortic tunnel in two patients, and septa1 malalignment, restrictive VSD, and abnormal suture placement each in one patient. Unique views could be obtained equivalent to surgical or autopsy dissections, and allowed more complete understanding of morphology than conventional imaging techniques. (ECHOCARDIOGRAPHY, Volume 11, November 1994) three-dimensional echocardiography, ventricular outflow obstruction Subaortic stenosis may occur due to a variety of structural malformations. An accurate morphological understanding is critical to planning and pedorming surgical treatment. Up until recently, two-dimensional echocardiography or angiography were the preferred imaging techniques.= Wee-dimensional imaging has now become feasible for echocardiographic use. 7 Three-dimensional echocardiography of structural anomalies of the subaortic left ventricular outflow tract has recently been reported! The technique employed utilized a transducer designed for transesophageal use in which parallel echo scans or slices were sequentially obtained across the chest, as the transducer was mechanidy withdrawn within a carriage to obtain a dataset? Recently a rotational acquisition system has been developed in which a standard, commercially Address for correspondence and reprints: Derek A. Fyfe, M.D., Ph.D., The Children s Heart Center, 2040 Ridgewood Dr. NE, Atlanta, GA 30322. Fax: 404-248-5110. available, transthoracic echo transducer is placed in a rotating mechanical motorized holder, and sequential scans are obtained. Slices of these propeller-like scans are then analyzed, synthesized, and displayed. This technique has significant technical adva&ages over other techniques, as only a single echocardiographic window is required for all image acquisition. To evaluate the diagnostic utility of rotational acquisition, we performed three-dimensional imaging in a series of patients with a spectrum of obstructive lesions of the left ventricular outflow tract. Unique views obtained with three-dimensional reconstruction simulated those only obtainable during surgical exposure or anatomical dissection. Methods A prototype dynamic three-dimensional acquisition and processing system (Tomtec, Broomfield, CO, USA) was used, linked to commercially available Interspec Apogee (Ambler, Vol. 11, No. 6,1994 ECHOCARDIOGRAPHY: A Jrnl. of CV Ultrasound & Allied Tech. 607

FYFE, ET AL. PA, USA) or CX 200 echocardiography systems already in clinical use. Either 7.5, 5-, or 3.5-MHz probes were used, mounted in a cylindrical, motorized transducer holder. After a clear transthoracic or subxiphoid echo window, which included the region of interest, was located, the transducer was locked in this position with the use of a mounting arm. The probes were mechanically rotated 180" in 1"-2" increments by the stepper motor during data acquisition. The data collection was gated for both cardiac cycle and respiration using standard ECG connections. The image acquisition was monitored on the echocardiographic machine during rotation. Following image acquisition, the computer was disconnected from the echo machine and offline processing was performed by selection of critical regions of interest. Datasets were oriented and then cut in differing planes to obtain the optimal imaging orientation for display. Surface and volume rendering was then performed. Patient Preparation Infants and children were examined at the conclusion of standard echocardiography examinations, which were being performed as a clinical service. In some cases, sedation had been administered for the clinical exam, and patient monitoring adhered to established guidelines for pediatric sedation.'o Data collection usually required about 5-10 minutes to set the transducer holding arm in position, optimize the image, and calibrate the system. The actual scan time to acquire a complete dataset was 1-2 minutes for each echocardiographic window once the views were optimized. The patients were then dismissed from the laboratory and image analysis performed off line. Reconstruction to the first image following orientation and selection of thresholds, choice of pixel density, and application of surface shading techniques could be achieved in as short a time as 10 minutes. If higher pixel density was selected, computation was slightly longer. Examination Windows Standard subxiphoid, apical, and parasternal transthoracic echocardiographic windows were used for image acquisition, depending on which window provided the best access to imaging the relevant anatomy. Results Thirteen patients with subaortic obstruction were studied ranging in age from 2 days to 17 (median 1) years of age (Table I). Five patients required sedation for study. TABLE I Weight Patient Age kg Diagnosis 3-D Echo Window 1 3months 4 discrete membranous left parasternal 2 4 months 4.2 discrete membranous left parasternal 3 6months 6 IHSS right parasternal 4 2years 15 tunnel left parasternal 5 4years 25 IHSS left parasternal 6 4%years 30 discrete membranous left parasternal 7 lyear 8 recurrent discrete subxiphoid 8 4years 17 tunnel left parasternal 9 2days 3.0 malaligned septum, IAA subxiphoid 10 4months 7.2 DORV, restrictive VSD subxiphoid 11 6years 28 discrete membranous subxiphoid 12 8years 29 discrete membranous subxiphoid 13 17years 68 discrete membranous apical IHSS = idiopathic hypertrophic subaortic stenosis; IAA = interrupted aortic arch DORV = double outlet right ventricle; VSD = ventricular septa1 defect. 608 ECHOCARDIOGRAP~ A Jrnl. of CV Ultrasound & Allied Tech. Vol. 11, No. 6, 1994

THREE-DIMENSIONAL ECHOCARDIOGRAPHY LV OUTFLOW OBSTRUCTION Figure lk Three-dimensional reconstruction showing the full extent of a tunnel-like abnormality (arrows) shown in a long-axis cut. Figure 1B. Shows the subaortic tunnel in cross-section viewed from within the ventricle looking up at the aortic valve (AV). MV = rnitral valve. Vol. 11, No. 6,1994 ECHOCARDIOGRAPHY: A Jml. of CV Ultrasound & Allied Tech. 609

FYFE. ET AL. Figure 2. Three-dimensional view of subaortic septal malalignment from subxiphoid window. The malaligned subaortic septum can be seen as the obstructive lesion (S). The right ventricle (RV) is seen through the VSD, which is seen below and its septal margins spatially defined. VSD = VSD; LA = left atrium; LV = left ventricle; MV = mitral valve. Subaortic Obstruction Tunnel subaortic stenosis was examined in two cases (Fig. 1). The tubular nature of the obstruction is well displayed using views in which the outflow tract is cut longitudinally from apex to base and viewed from an anterior location. The diffuse distribution of the obstructive tissue is seen with circumferential narrowing due to the muscular obstruction, extending from aortic to mitral leaflets. Subaortic Septal Malalignment A patient of 2 days of age, weighing 3.0 kilograms, with normally related great vessels, ventricular septal defect (VSD), and interruption of the aortic arch type B is shown. The left ventricular (LV) outflow views are shown (Fig. 2). The dataset was cut from apex to base alongside the ventricular septum. The discontinuity and malalignment of the subaortic ventricular septum is clearly seen as is the crest of the large VSD. A second view was obtained in which the VSD and subaortic septum are examined en face, as if the observer is standing on the inside free wall of the left ventricle looking toward the septum (Fig. 3). The size and relations of the VSD are appreciated easily, and the posterior and anterior extension of subaortic septum is well seen. Iatragenic Septal Outflow Obstruction Following closure of a VSD, which was inadvertently created during resection of a subaortic membrane, a large partially obstructive pledgetted suture was placed in the left side of the septum in the outflow tract. The discrete nature of this lesion is clearly appreciable looking from the apex of the heart into the outflow tract toward the aortic valve (Fig. 4). Restrictive Ventricular Septal Defect Left ventricular outflow obstruction &r repair of double outlet right ventricle was also 610 ECHOCARDIOGRAPW: A Jrnl. of CV Ultrasound & Allied Tech. Vol. 11, No. 6, 1994

THREE-DIMENSIONAL ECHOCARDIOGRAPHY LV OUTFLOW OBSTRUCTION Figure 3. View of the LVOT in a child (also seen in Fig. 2) with subaortic septa1 malalignment looking en face at the septum IS) above and below the large muscular VSD viewed from LVfreewall. LVOT = left ventricular outflow tract; LV = left ventricle. Figure 4. Three-dimensional view from LV looking up at a pledget-suture protruding into the outflow tract below the aortic valve. Left and right panels shows alternative surface shading techniques. LV = left ventricle. Vol. 11, No. 6,1994 ECHOCARDIOGWm A Jrnl. of CV Ultrasound & Allied Tech. 611

FYF'E, ET AL. Figure 5. Long-axis views of a restrictive VSD and a portion of the left ventricle to aortic tunnel after double outlet right ventricle repair. The RVOT connection to the pulmonary artery is not seen. VSD = ventricular septal defect; RVOT = right ventricular outflow tract. defined in one patient (Fig. 5). The outflow obstruction was due to a restrictive VSD and the relation to the great arteries was well appreciated. Hypertrophic Cardiomyopathy Two patients with idiopathic subaortic stenosis were studied showing the dynamically changing septal thickening as the cause of obstruction. Discrete Fibrous Subaortic Stenosis This was the most frequent lesion examined (six patients). The complete extent of the subaortic membrane is seen crossing the outflow tract viewed in long axis (Figs. 6 and 7). This can be best appreciated from the ventricular side of the outflow tract looking toward the aortic valve. In a surgeon's eye view through the aortic valve, the position and severity of obstruction can likewise be clearly defined (Fig. 8). Discussion Subaortic stenosis may occur due to a spectrum of structural abn~rmalities.'-~ Two-dimensional echocardiography or contrast angiography have usually provided the diagnostic imaging, however, in both techniques, the cardiologist must create a mental three-dimensional image, and may need also to try to convey this structural information to a surgeon. Three-dimensional echocardiography in this study allowed a more lifelike spatial representation of the anatomical details of the various morphological causes of subaortic obstruction, which can help in understanding and in planning surgery. Long and short axial alignments through cut surfaces provided unique images in all cases. The rotational acquisition system utilized in this study is a new technique that avoids many previous problems with image location and registration, as the probe gathers the entire dataset from one location. F'revious reports have used 612 ECHOCARDIOGRAPW: A Jrnl. of CV Ultrasound & Allied Tech. Vol. 11, No. 6,1994

THREE-DIMENSIONAL ECHOCARDIOGRAPHY LV OUTFLOW OBSTRUCTION Figure 6. Three-dimensional view in a unique projection, looking from the inside of the left ventricle into the outflow tract. The membrane (M) is protruding into the outflow tract during systole. MV = mitral valve. Figure 7. Three-dimensional view of subaortic fibrous membrane in a similar orientation to a parasternal long-axis scan. An incomplete membrane (arrow) is seen below the aortic valve. The extent of the membranous obstruction is well seen. A 0 = aorta; LA = left atrium. Vol. 11, No. 6, 1994 ECHOCARDIOGRAPHY: A Jrnl. of CV Ultrasound & Allied Tech. 613

FYFE. ET AL. Figure 8. Long-axis views of a discrete membrane at an unusually long distance of the valve. parallel slicing techniques, which require the imaging transducer to slide over the chest, limiting to some extent the windows for data acquisiti~n.~ The rotational acquisition system has the advantage that a single window can optimally provide a site for data acquisition which is not limited by ribs, etc., as a sliding probe in a carriage may be. Subxiphoid windows are most easily utilized with little or no perception of movement of the probe by the patient. Subxiphoid windows may be potentially less likely to have problems of probe motion due to respiratory excursion of chest wall. Also, there is the potential for high resolution due to overlap of scan planes at the center of the dataset. Apical positions may be more difficult due to the chest wall movement interfening with the ability to hold the transducer in a stable position while maintaining constant contact. However, in this study, when stable contact was obtained, excellent clarity of images was achieved. The disadvantages of the rotational acquisition method are that it may have limited resolution in the far field due to the increasing separation of scan planes as the distance from center of dataset increases. This problem can be reduced or avoided by centering the primary region of interest in the screen during data acquisition. Rotational artifacts also occur due to the 180 scan set needed to maintain a perfect center of rotation during the acquisition in order to align data from opposite sides of the imaging fan following rotation. Currently, Doppler flow can be visualized, but only in a gray scale image superimposed upon the echocardiographic image. More research into quantitative aspects of color flow and three-dimensional reconstruction is necessary before clinical information can be assessed. In summary, unique new views of the heart in this study of the left ventricular outflow tract, equivalent to those which could be seen only by surgical or autopsy exposure, were accomplished. Lifelike views allow full appreciation of surgically important structures in real time. These surgical views have surfaces and, therefore, are unlike the shadows obtained by catheterization or two-dimensional echocardiography. The potential for image manipulation in virtual reality creates the possibility for experimental pseudo - 614 ECHOCARDIOGRAPHY: A Jrnl. of CV Ultrasound & AUied Tech. Vol. 11, No. 6,1994

THREE-DIMENSIONAL ECHOCARDIOGRAPHY LV OUTFLOW OBSTRUCTION surgical computer modeling prior to the actual performance of definitive surgical procedures, and may allow an accurate analysis of the likely surgical result. References 1. Edwards JE: Pathology of ler ventricular outflow tract obstruction. Circulation 1965;32:586-599. 2. Kandah T, Kimball TR, Daniels SR, et al: When is echocardiography unreliable in patients undergoing catheterization for pediatric cardiovascular disease? J Am SOC Echo 1991;4:51-56. 3. Wilcox WD, Seward JB, Hagler DJ, et al: Discrete subaortic stenosis: Two-dimensional echocardiographic features with angiographic and surgical correlation. Mayo Clin Proc 1980;55:425-432. 4. Vogel M, Freedom RM, Brand A, et al: Ventricular septal. defect and subaortic stenosis: An analysis of 41 patients. Am J Cardiol 1983;52:1258-1263. 5. Sheikh KH, Smith SW, von Ramm 0, et al: Real-time, three-dimensional echocardiography: Feasibility and initial use. Echocardio- 6. 7. 8. 9. 10. graphy 1991;8: 119-125. King DL, Harrison MR, King DL Jr, et al: Improved reproducibility of left atrial and left ventricular measurements by guided threedimensional echocardiography. JACC 1992; 20~1238-1245. Pandian NG, Nanda NC, Schwartz SL, et al: Three-dimensional and four-dimensional transesophageal echocardiographic imaging of the heart and aorta in humans using a computed tomographic imaging probe. Echocardiography 1992;9:677-687. Vogel M, Losch S, Buhlmeyer K. The application of transthoracic dynamic three-dimensional echocardiography by computer-controlled parallel slicing in patients with fixed subaortic obstruction. Cardiol Young 1994;4:7-14. Wollschlager H, Zeiher AM, Klein HP, et al: Transesophageal echo computer tomography: A new method for dynamic 3-D imaging of the heart (abstract). Circulation 1989;8O:II-569. Committee on Drugs: Guidelines for monitoring and management of pediatric patients during and arer sedation for diagnostic and therapeutic procedures. Pediatrics 1992;89: 1110-1115. Vol. 11, No. 6,1994 ECHOCARDIOGWHY: A Jml. of CV Ultrasound & Allied Tech. 615