HP Knee Extraction Instrumentation. Product Overview

Similar documents
HP KNEE EXTRACTION Instrumentation. Product Overview

28 Surgical Technique

SHOULDER EXTRACTION INSTRUMENTS

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

This publication is not intended for distribution in the USA.

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

TOTAL KNEE ARTHROPLASTY SYSTEM

INSTRUMENTS. Design Rationale

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

INSTRUMENTS. Product Rationale

Triathlon TS Knee System. Surgical Protocol

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Surgical Technique. Hinge Disassembly and Rebuild Technique

U2 PSA. Revision Knee. Surgical Protocol

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

MIS Cemented Tibial Component

RECLAIM REVISION SOLUTIONS

ANATOMIC SURGICAL TECHNIQUE. 5 in 1. Conventional instrumentation 07/11/2013

LAMINA SPREADER SURGICAL TECHNIQUE

Scorpio TS Single Axis Revision Knee System. Scorpio Total Stabilizer Revision Knee System Surgical Protocol

Distal Cut First Femoral Preparation

TRIAL COMPONENTS SURGICAL TECHNIQUE REAMING THE TIBIAL AND FEMORAL INTRAMEDULLARY CANAL

Zimmer NexGen Trabecular Metal Tibial Tray

Constrained Posterior Stabilized (CPS) Surgical Technique

EXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM

Intramedullary Tibial Preparation

Fixed and Variable Geometry Total Shoulder Arthroplasty

Optimum implant geometry

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Technique Guide. Epoca Revision Instrument Set. For extraction and revision of Epoca shoulder implants.

ELEOS Limb Salvage System

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

OSS Modular Arthrodesis System. Assembly Guide

Surgical Technique. Unisyn Hip System

TRK REVISION KNEE Surgical Technique

Mako. Total Knee with Triathlon. Surgical protocol

Ease of Use. Have the instrument you need when you need it.

Optimum implant geometry

Extramedullary Tibial Preparation

Unicondylar Surgical Technique

Resurfacing Distal Femur. Orthopaedic Salvage System

Constrained Posterior Stabilized (CPS)

Triathlon Knee System

ANATOMIC LOCKED PLATING SYSTEM

Proven Gen-Flex Revision Knee System. Surgical Protocol

The information contained in this document is intended for healthcare professionals only.

SCORE Revision. Revision Total Knee Arthroplasty Cemented. Surgical Technique With Conventional Instrumentation Primary cases

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Bone Preservation Stem

Aseptic Revision Total Knee Surgical Techniques. Andrew Ehmke, DO Chicago, IL May 5, 2018

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

ELEOS Limb Salvage System

NATURAL MOTION TECHNOLOGY SURGICAL TECHNIQUE. EMPOWR 3D Knee. EMPOWR PS Knee

NexGen Trabecular Metal Tibial Tray. Surgical Technique

Surgical Technique with Offsetting Instruments

Zimmer MOST Options System

LPS SYSTEM POCKET GUIDE

Anatomical Shoulder System

Approach Patients with Confidence

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Femoral / Tibial Augmentation. Orthopaedic Salvage System

Optimum implant geometry

Featuring. Technology. Product Rationale

Pin Guide System. Surgical Technique

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

NeoGen Femoral Nail System

4.5 System. Surgical Technique. This publication is not intended for distribution in the USA.

Biomet Large Cannulated Screw System

operative technique Kent Hip

The Bio-Modular Choice Shoulder System,

FLK167 02/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel Fax:

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

Profix. Total Knee System. As described by

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Operative Technique. Constrained Condylar. The Right Track It s not just a road we re on, it s a trail we re blazing.

LCS COMPLETE Revision Knee System. Surgical Technique

Triathlon Knee System Universal Baseplate Surgical Protocol

S U R G I C A L T E C H N I Q U E David A. McQueen, MD Return to Menu

Rotating Platform. stabilityinmotion

Trilogy Acetabular System

Clinical Evaluation Surgical Technique

Knee Revision. Portfolio

NeoGen Tibia Nail System

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

The new removable head option. Anatomical Shoulder System

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique. IMAGE TO COME Designed for minimally invasive procedures

GMRS Proximal Tibial Surgical Protocol

The information contained in this document is intended for healthcare professionals only.

Trilogy Acetabular System

OPTIONAL/ADDITIONAL INSTRUMENTS

IM Hip Nailing Surgical Technique

ANTERIOR REFERENCE NEXGEN COMPLETE KNEE SOLUTION. Multi-Reference 4-in-1 Femoral Instrumentation Anterior Reference Surgical Technique

Triathlon Knee System. Universal Baseplate Surgical Protocol

Minimally Invasive System for Total Hip Arthroplasty. Surgical Technique

Revolution. Unicompartmental Knee System

Transcription:

HP Knee Extraction Instrumentation Product Overview

HP Extraction Knee Instruments DePuy Orthopaedics is working with Symmetry Medical * to distribute Advanced Knee Extraction instruments. These instruments provide confidence through solid construction, ease of use, and multiple options to address implant removal. The HP Extraction Knee Instruments complement the DePuy Orthopaedics comprehensive portfolio of revision implants and instruments. They are designed to address obstacles encountered during revision TKA (Total Knee Arthroplasty). The HP Extraction Knee Instruments are another example of DePuy Orthopaedics commitment to providing implants and instruments that address two of the biggest reasons for revision knee failure: loosening and instability. 1 Addressing Loosening with Rotating Platform Addressing Instability with Metaphyseal Sleeves *Manufacturer: Symmetry Medical, Inc. 3724 North State Road 15, Warsaw, IN 46582, USA 1

HP Extraction Standard Removal Case 2011-03-048 Top Level: HP Revision General Extraction Instrument Set Top Level HP Revision Extraction Instrument Case 2011-03-048 HP Extraction 7 mm V Split 305 mm 2011-03-034 HP Extraction 7 mm Reverse Curette 305 mm 2011-03-035 HP Extraction Offset Chisel 2011-03-036 HP Extraction Component Impactor 2011-03-037 HP Extraction Straight Osteotome 7 mm 2011-03-038 HP Extraction Straight Osteotome 12.5 mm 2011-03-039 HP Extraction Straight Osteotome 20 mm 2011-03-040 2

Bottom Level: HP Revision General Extraction Instrument Set Bottom Level Handle With Quick Coupling End (2) 2709-04-001 Small Slap Hammer 2709-04-002 Flexible Osteotome System 2709-04-100 HP Extraction Removal Screw 8 mm 2011-03-042 HP Extraction 254 mm Cement Rongeur 2011-03-044 3

HP Extraction 7 mm V Split 305 mm Osteotome (2011-03-034) Use the 7 mm V Osteotome to fragment bone cement remaining in the proximal tibia after removal of the tibial component. HP Extraction 7 mm Reverse Curette 305 mm (2011-03-035) Use the 7 mm Reverse Curette to hook cement fragments in the proximal tibia after removal of the tibial component. The 7 mm Reverse Curette can also be used to scrape the distal femoral canal after removal of the femoral component. HP Extraction Offset Chisel (2011-03-036) Use the Offset Chisel to develop a plane between the femoral component and the bone cement in the intercondylar notch. This instrument may also be used to chip away bone cement in the posterior region of the proximal tibia and around the patellar component. 4

HP Extraction Component Impactor (2011-03-037) A Component Impactor is provided to assist in removal of either a femoral or tibial component after the components have been loosened. HP Extraction Straight Osteotomes (2011-03-038, 039, & 040) Three Straight Osteotomes are provided to develop a plane between an implant and the bone cement and to fragment the bone cement. They have widths of 7 mm, 12.5 mm, and 20 mm respectively. 5

Flexible Osteotome Blades & Handle With the Quick-Coupling Handle (2709-04-001) to develop a plane, use the Flexible Osteotome Blades (2709-04-004 to 2709-04-011) between an implant and bone. There are four blade widths 8 mm, 10 mm, 12 mm, and 20 mm. These osteotomes are not rigid enough to pry and wedge. If these actions are necessary, use the Straight Osteotomes (2011-03-038 to 2011-03-40 listed above). Small Slap Hammer (2709-04-002) The Small Slap Hammer can be used if the flexible Osteotomes get stuck. The Slap Hammer can be attached to the Quick Coupling Handle to extract the Flexible Osteotomes. HP Extraction 8 mm Extraction Screw (2011-03-042) Use the 8 mm Extraction Screw to remove polyethylene components. A 6.4 mm drill bit can be used to create a hole which will accept the Extraction Screw. When an all-polyethylene tibial component is to be removed, the Extraction Screw is threaded into the pre-drilled hole and its collar is impacted with a mallet. The Extraction Screw may also be used to facilitate removal of a polyethylene tibial insert. 6

HP Extraction 254 mm Cement Rongeur (2011-03-044) The 254 mm Cement Rongeur is used to extract cement in the tibial and femoral canal after the components have been removed. The long, narrow arm is able to reach deep into both canals. The handle can be then be pressed together to cinch the arm s mouth together to remove cement that is difficult to access. 7

HP Extraction Sleeve Removal Case 2011-03-058 HP Revision Sleeve Extraction Instrument Set 2011-03-200 HP Revision Sleeve Extraction Case 2011-03-058 HP Femoral Impactor/Extractor 9505-01-171 HP Slap Hammer 9505-01-308 Small Slap Hammer 2709-04-002 HP Extraction Tibial Component Remover 2011-03-045 HP Extraction MBT Sleeve Extractor 2011-03-031 HP Extraction MBT Sleeve/Tray Separator Tool 2011-03-053 HP Extraction TC3 Tuning Fork 2011-03-030 Stem Trial Extractor 86-5226 HP Extraction Stem Trial Extractor Adapter 2011-03-047 Locking Pliers 2709-03-006 HP Extraction Vice Grips Adapter 2011-03-046 8

HP Femoral Impactor/Extractor (9505-01-171)* The Universal Femoral Impactor/Extractor is designed to work with LCS and SIGMA femurs. The A/P spring loading mechanism, in conjunction with the adjustable M/L wings, allows it to fit onto any size LCS and SIGMA femoral component. The Impactor/Extractor can then be locked down onto the femoral component, by turning it in a clockwise motion (to release turn counter clockwise). The Impactor/Extractor works with the 9505-01-308 HP Slap Hammer. *This instrument is for extraction of the trials not for implants HP Slap Hammer (9505-01-308) The HP Slap Hammer features a quick connect end that assembles to the HP Femoral Impactor/ Extractor (9505-01-171). It also has an ergonomic handle and a modified slide bar to allow the surgeon to slap the component out, or put varus/valgus torque on the femur. Locking Pliers (2709-03-006) and HP Extraction Locking Pliers Adapter to Slap Hammer Adaptor (2011-03-046) Among many uses, the Locking Pliers are helpful in removing femoral sleeve trials or implants. The vice grips can be locked onto the distal portion of a femoral sleeve (if the sleeve is an implant, Osteotomes need to be used to get access to the sleeve). The Small Slap Hammer (2709-04-002) can then be attached to the Locking Pliers via the Locking Pliers Adapter (2011-03-046). 9

HP Extraction MBT Tray/Sleeve Separator (2011-03-053) The MBT Tray/Sleeve Separator is inserted in between the inferior portion of the MBT Tray and the superior portion of the MBT Tray sleeve after proper exposure has been achieved. Once impacted, the separator is designed to break the taper between the MBT tray and MBT sleeve. This is especially useful if a 14 mm or small universal stem was used with the tibia. If this is the case, the tibia and stem can be pulled out through the MBT sleeve after separation. Then the surgeon can work on removing the sleeve. HP Extraction TC3 Tuning Fork (2011-03-030) The HP TC3 Tuning Fork is designed to break the morse taper between the TC3 femoral component and the universal sleeve. The Tuning Fork can be inserted into the medial or lateral portion box, between the box and femoral component. It can then be impacted to disengage the taper between the femur and sleeve. Stem Trial Extractor (86-5226) and HP Extraction Stem Trial Extractor to Slap Hammer Adapter (2011-03-047) The Stem Trial Extractor threads into and removes stem trials (pilots) that have become stuck in the femoral canal. The Stem Trial Extractor can also be threaded through a sleeve into the stem trial (or pilot) to remove a sleeve/ stem trial construct that is stuck in the femur. For additional extraction force, the Small Slap Hammer (2709-04-002) can be attached to the stem trial extractor via the stem trial to Slap Hammer Adaptor (2011-03-047). 10

HP Extraction MBT Sleeve Remover (2011-03-031) The MBT Sleeve Remover is used to remove sleeves trials or implants that are stuck in the tibial canal. The two prongs are inserted through the proximal portion of the sleeve, passed all the way through the sleeve, and then out the other side. The handle is then turned clockwise to open up the prongs and engage the prongs steps on the distal aspect of the sleeve. To aid in removal, the Small Slap Hammer (2709-04-002) can be attached to impact the sleeve out. HP Tibial Component Extractor (2011-03-045) The Tibial Component Extractor can be used to remove tibial trays, trays and stems, or trays, stems, and sleeves that are fixed together. The base of the tibial tray should first be exposed with Osteotomes and the polyethylene insert removed from the tray. Once exposed, the tibial component extractor prongs are inserted below the base of the tray. The locking screw is then tightened down onto the superior portion of the tray. The Small Slap Hammer is then attached and used to impact the entire tibial tray construct out as one piece. HP Tibial Component Extractor Replacement Straight Blades (2011-03-054) and Offset Blades (2011-03-055) and Replacement Tibial Component Extractor Hex Wrench (2011-03-056) The tibial component blades come in two options: Standard and Offset. The Offset Blades work with the MBT tray, MBT revision tray system, and other systems with wide/broad keels. The blades come with screws that are threaded to the extractor (2011-03-045). If screws are lost, a replacement set of blades must be ordered. The screws are tightened down using the L shaped hex wrench. 11

HP Extraction Sleeve Removal Case 2011-03-058 HP Extraction Standard Removal Case 2011-03-048 HP Extraction 7 mm V Split 305 mm 2011-03-034 HP Extraction 7 mm Reverse Curette 305 mm 2011-03-035 HP Extraction Offset Chisel 2011-03-036 HP Extraction Component Impactor 2011-03-037 HP Extraction Straight Osteotome 7 mm 2011-03-038 HP Extraction Straight Osteotome 12.5 mm 2011-03-039 HP Extraction Straight Osteotome 20 mm 2011-03-040 HP Extraction Removal Screw 8 mm 2011-03-042 HP Extraction 25 mm Cement Rongeur 2011-03-044 Flex Osteotome Delivery System 2709-04-100 Handle with Quick Coupling End (2) 2709-04-001 Small Slap Hammer 2709-04-002 HP Extraction Sleeve Removal Case 2011-03-058 HP Extraction Tibial Component Remover 2011-03-045 HP Extraction Locking Pliers Adapter 2011-03-046 HP Extraction Stem Trial Removal Adaptor 2011-03-047 HP Extractor MBT Tray/Sleeve Separator 2011-03-053 HP Slap Hammer 9505-01-308 Small Slap Hammer 2709-04-002 Locking Pliers 2709-03-006 HP Extraction TC3 Tuning Fork 2011--03-030 HP Extraction MBT Sleeve Remover 2011-03-031 Stem Trial Extractor 86-5226 HP Femoral Impactor/Extractor 9505-01-171* Thin Osteotome Blade, 8 mm x 76 mm 2709-04-004 Thin Osteotome Blade, 10 mm x 76 mm 2709-04-005 Thin Osteotome Blade,12 mm x 76 mm 2709-04-006 Thin Osteotome Blade, 20 mm x 76 mm 2709-04-007 Thin Osteotome Blade, Curved End, 12 mm 2709-04-008 Thin Osteotome Blade, Curved End, 20 mm 2709-04-009 Thin Osteotome Blade, 8 mm x 127 mm 2709-04-010 Thin Osteotome Blade, 10 mm x 127 mm 2709-04-011 Replacement Codes HP Extract Tib Rem Bld Straight 2011-03-054 HP Extract Tib Rem Bld Offset 2011-03-055 HP Extract Tib Rem Hex Offset 2011-03-056 *Manufacturer: Enztec Ltd, 26 Dakota Crescent, Sockburn, Christchurch 8004, New Zealand 0086 12

References 1. Mulhall KJ, Callaghan JJ et al. Current Etiologies and Modes of Failure in Total Knee Arthroplasty Revision. Clinical Orthopaedics and Related Research - 2006;446:45-50. This publication is not intended for distribution in the USA. DePuy Orthopaedics EMEA is a trading division of DePuy International Limited. Registered Office: St. Anthony s Road, Leeds LS11 8DT, England Registered in England No. 3319712 DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46581-0988 USA Tel: +1 (800) 366 8143 Fax: +1 (574) 267 7196 www.depuy.com DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0)113 387 7800 Fax: +44 (0)113 387 7890 0086 DePuy International Ltd. and DePuy Orthopaedics, Inc. 2012. All rights reserved. 9085-57-000 version 2 Issued: 11/12 CA#DPEM/ORT/1112/0359