E-Cigarette Aerosol Analysis Report

Similar documents
E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report

Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China

The Effect of Puff Profile and Volume on the Yields of E-Cigarettes

CORESTA Recommended Method No. 84

The Chemical characterisation of E-device Aerosols

CORESTA Recommended Method No. 78

CORESTA RECOMMENDED METHOD N 8

CORESTA RECOMMENDED METHOD NÄ 9

E-Vapour (EVAP) Sub-Group 2017 Report. Kitzbühel, Austria October 10, 2017

CORESTA Recommended Method No. 74

METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES

Air Quality assessment during indoor use of the Tobacco Heating System 2.2

October 2, 2018 Japan Tobacco Inc. The Effects of T-Vapor products on Indoor Air Quality

Air Quality assessment during indoor use of the Tobacco Heating System 2.2

Verification Report. Report No.:RLSZD Page 2 of As specified by client, to determine the Lead, Cadmium,

Matt S. Melvin, Karen C. Avery, Jason W. Flora, Karl A. Wagner. Altria Client Services LLC l Regulatory Sciences 12Oct2016 Final 1

Test Report. No. CANEC Date: 07 Aug Page 1 of 11.

Analysis of e-liquid and e-cigarettes Vapoting test results

PROVINCE OF BRITISH COLUMBIA ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

S.C. Moldoveanu, A.G. Hudson, A. Harrison. R.J. Reynolds Tobacco Co.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

THE INFLUENCE OF CIGARETTE FILTER DESIGN ON THE YIELD AND COMPOSITION OF CIGARETTE SMOKE

CORESTA Recommended Methods with history and correspondence with ISO Standards

CORESTA RECOMMENDED METHOD N 25

A New Method for the Analysis of Carbonyl Compounds in e-cigarette Liquids

E-Cigarettes: Current Perspective

Evaluation of the Potential for Second-hand Exposure to E-cigarette Aerosol in an Office Environment

Test Report. No. CANEC Date: 13 Feb 2018 Page 1 of 10

The Effect of Puff Duration on Smoke Chemistry

Stop the Vape. Maria Hines RN, MSN. Denise Kneubuhler RN, MSN

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

E-Cigarette Product Regulation and Standardisation

ONLINE AEROSOL ANALYSIS USING FTIR: ASSESSING CARBONYL YIELDS IN E-CIGARETTE AEROSOL

CORESTA RECOMMENDED METHOD N 22

UK E-Cigarette Summit Relative risks of cancer posed by combustible and vapourising forms of nicotine delivery: Evidence from chemical exposures

Effect of Sugars on Selected Toxicant Yields in e-cigarettes

Test Report. Report No.RLSZE Page 1 of 17

Technical Report Collaborative Study on Carbonyl Containing Compounds in Electronic Cigarette Liquids

Test Report No.T JP Date: FEB 22, 2017 Page 1 of 6

Analysis of Components from Gamucci Electronic Cigarette Cartridges, Tobacco Flavour Regular Smoking Liquid

Particle Size Distribution of E-Cigarette Aerosols and the Relationship to Cambridge Filter Pad Collection Efficiency

The fitness for purpose of existing tobacco product test methods identifying the gaps

Forensic Analysis of Blood Alcohol Concentration

Test Report No.T TC Date: JUN 29, 2018 Page 1 of 5

Routine Analytical Chemistry Sub-Group Report Berlin 2016

CATCH MY BREATH. ASHA Conference: October 12, Marcella Bianco CATCH My Breath Program Manager CATCH Global Foundation

Vapes, Ecigs, Mods, Juuls. Chris Harnish Mercer Island Youth & Family Services

Test Report. Report No.RLSZE Page 1 of 16

FEATURES AND PERFORMANCE OF THE HPP SMOKING MACHINE. Dritan Xhillari

RISK FROM E-VAPOUR PRODUCTS FOR USERS AND BYSTANDERS

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

Validation of Changes to the USP Assay Method for Ibuprofen Tablets

HUMAN LIVER SLICE EXPERIMENT 1 Effects of Propylene Glycol on Ethylene Glycol Metabolism

SCOPE OF ACCREDITATION

Innokin Technology Co., Ltd. Building 6, XinXinTian Industrial Park, Xinsha Road Shajing Baoan District, Shenzhen, China P.R.C.

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PAEDIATRIC RETINOL ORAL SOLUTION (August 2010)

REVISED DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA RETINOL CONCENTRATE, OILY FORM. (August 2010)

Test Report No.T JP Date: FEB 24, 2017 Page 1 of 6

Harmful and potentially harmful constituents in e-cigarettes

Pierre-Marie GUITTON Next Generation Nicotine Delivery London June, 2017

Cigarettes Determination of tobacco specific nitrosamines in mainstream cigarette smoke Method using LC-MS/MS

Analysis of Chemical Components from High, Med & Low Nicotine Cartridges

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ENTHALPY ANALYTICAL, INC East Parham Road Richmond, VA Gwen Vaughan Phone:

FIt s a late summer s afternoon in Jarrow, A LAB OF ITS TIME

Contribution To Standards Development For Next Generation Products. Dr Nils ROSE

CORESTA Guide N o 18

PAPRIKA EXTRACT SYNONYMS DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

TNCO Testing procedures

Guideline for Measurement Method of Harmful Ingredients in Cigarette-type Smoking Craving Suppressant

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA: CARBAMAZEPINI COMPRESSI - CARBAMAZEPINE TABLETS

David S. Goya, DO, MBA, FCCP, FACP Kaiser Permanente Medical center Santa Clara, California

Contribution To Standards Development For Next Generation Products. Eduardo BEREA Alternative Ingredients ENDS 2018 London 4-5 June 2018

CORESTA RECOMMENDED METHOD N 39

Preventing Youth Electronic Cigarette Use: Partnering with Schools

ARTESUNATE TABLETS: Final text for revision of The International Pharmacopoeia (December 2009) ARTESUNATI COMPRESSI ARTESUNATE TABLETS

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

The Changing Landscape of Tobacco: E-Cigarettes, E-Hookahs and More

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON LAMIVUDINE TABLETS

The electronic cigarette (personal nicotine vaporizer)

ELECTRONIC CIGARETTE EVOLUTION FROM FIRST TO FOURTH GENERATION PRODUCTS AND BEYOND

Measuring Emissions as Part of a Regulatory Regime. Prof. Riccardo Polosa Professor of Internal Medicine and Convenor CEN TC437/WG4

A combination of licensed medication and professional support is four times more likely to achieve a stop in smoking behaviour.

Contents. 01 Welded Syringe Filter Economy Syringe Filter Sterile Syringe Filter Membrane Filter 21

Calibration Factors and Time-and-Distance Guidelines For Use of Theatrical Fog Equipment

CORESTA Recommended Method No. 56

West Milford Township Public Schools. Substance Abuse Policy and Regulation Review. and Vape Education for Parents. April 26, 2018

VAPING: What you need to know

DEVELOPMENT OF A TECHNIQUE FOR THE DETERMINATION OF ph-values OF AEROSOLS GENERATED BY E-CIGARETTES

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

IMPACT OF VARIOUS AIR EXCHANGE RATES ON THE LEVELS OF ENVIRONMENTAL TOBACCO SMOKE (ETS) COMPONENTS

Transcription:

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: of 9 Applicant: Address: ALD GROUP LIMITED ALD Building NO.2 Industrial 3rd Road, ShiXin Community, Shiyan Town, Bao An District, Shenzhen 5808, China. The following sample was submitted and identified by/on behalf of the client as: Sample Name: A9-3SH(tobacco 8mg) Model No.: A9-3SH tobacco 8mg MOD: 280mah Tank:.6g/ PC Silicone Coil: 3.ohm/ Fiberglass rope Cotton Iron-Chrome-Aluminum Power level in testing: Voltage/Wattage of tested sample is un-adjustable Adjustable air inlet or not: No Trade Mark: Smokesmart Sample Received Date: 207.2.26 Testing Period: 207.2.26 208.0.04 Test Requested:. As specified by client, to determine the Carbonyl Compounds content(s) in aerosol generated by the submitted sample. 2. As specified by client, to determine the Metals content(s) in aerosol generated by the submitted sample. 3. As specified by client, to determine Nicotine consistency in aerosol generated by the submitted sample. 4. As specified by client, to determine Diacetyl and Pentane 2,3 dione content(s) in aerosol generated by the submitted sample. 5. As specified by client, to determine Ethylene Glycol and Diethylene Glycol in aerosol generated by the submitted sample. 6. As specified by client, to determine Specific Nitrosamines content in aerosol generated by the submitted sample. 7. As specified by client, to determine VOC substances content(s) in aerosol generated by the submitted sample. Test Method: Please refer to the following page(s). Test Result(s): Please refer to the following page(s). Checked by Signed for and on behalf of TCT Chris Zhong Kim Zhang Technical Manager

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 2 of 9 Test Results: Test Condition for test items except Nicotine consistency test: With reference to the CORESTA RECOMMENDED METHOD Nº 8 method parameter and Afnor standardization XP D90-300-3, a smoke machine was used to collect the vapor. Puff Duration 3.0s±0.s Puff Volume 55mL±0.3mL Puff Frequency 30s±0.5s Puff of Each Group 20 Group Interval Time 300s±20s Maximum Flow 8.5mL/s±.0mL/s Pressure Drop < 50hPa Group 5 Total Number of Puff 00 Total Duration of Vaporization 300s The temperature and relative humidity of the test atmosphere during machine preparation and testing shall be kept within the following limits: temperature ±2, relative humidity ±5% Sample Description:. A9-3SH(tobacco 8mg)

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 3 of 9. Carbonyl Compounds Method: Using volumes based on the desired dilution, a measured volume of sample was combined with a volume of DNPH solution and vortexed. After sitting for 20 minutes at ambient temperature, the sample was then quenched with a sufficient amount of pyridine. An aliquot was then analyzed using the Agilent Model 200, High Performance Liquid Chromatograph equipped with an Ultraviolet (UV) Detector operating at 365 nm. Formaldehyde 50-00-0 ug/00puffs 0.667 2 ND Acetaldehyde 75-07-0 ug/00puffs 0.667 2 ND Acrolein 07-02-8 ug/00puffs 0.667 2 ND Crotonaldehyde 470-30-3 ug/00puffs 0.667 2 ND

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 4 of 9 2. Metals Method: The vapor was passed through a dry-ice cooled impinger containing glass packing beads and quartz wool. After smoking the impinger was extracted with 5% nitric acid and filtered through quartz wool. An aliquot of the resulting solution was submitted for analysis by ICP-OES. Aluminium(Al) 7429-90-5 ug/00puffs 0.025 0.25 ND Chromium(Cr) 7440-47-3 ug/00puffs 0.005 0.05 ND Iron(Fe) 7439-89-6 ug/00puffs 0.005 0.05 ND Nickel(Ni) 7440-02-0 ug/00puffs 0.025 0.25 ND Tin(Sn) 7440-3-5 ug/00puffs 0.25 2.5 ND Lead(Pb) 7439-92- ug/00puffs 0.025 0.25 ND Cadmium(Cd) 7440-43-9 ug/00puffs 0.005 0.05 ND Arsenic(As) 7440-38-2 ug/00puffs 0.025 0.25 ND Antimony(Sb) 7440-36-0 ug/00puffs 0.025 0.25 ND

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 5 of 9 3. Nicotine Consistency Test Test Condition: With reference to the CORESTA RECOMMENDED METHOD Nº 8 method parameter and Afnor standardization XP D90-300-3, a smoke machine was used to collect the vapor. Puff Duration 3.0s±0.s Puff Volume 55mL±0.3mL Puff of Each Group 20 Maximum Flow 8.5mL/s±.0mL/s Pressure Drop < 50hPa The temperature and relative humidity of the test atmosphere during machine preparation and testing shall be kept within the following limits: temperature ±2, relative humidity ±5% Method: A reference liquid was prepared. A pharmaceutical nicotine inhaler was used as a comparator. Products were attached to a smoke machine, and the aerosol was collected in Cambridge filter pads. After trapping and solvent extraction, solution was analyzed by GC-MS and nicotine was dosed by comparing the areas obtained on the MS detector with those of standard solutions prepared in the laboratory under concentration conditions surrounding those of the samples. Sample Description Nicotine(CAS No.:54--5) Contents(mg / 20 Puffs) Group * Group 2 Group 3* Group 4 Group 5* AVG Total(mg/ 00puffs) A9-3SH(tobacco 8mg) 0.36 0.344 0.372 0.346 0.382 0.36.80 Deviation(%) 0-2.9-5.8 - - Note: - mg = milligram = 0.0 mg / 20 Puffs = 0. mg / 20 Puffs - group = 20 puffs - * Values used for determination of consistency of nicotine emission - Under the conditions of the test and with reference to AFNOR XP D90-300-3, the electronic cigarette delivers a dose of nicotine at consistent levels.

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 6 of 9 4. Diacetyl and Pentane 2,3 dione Method: The principle of collection and trapping of Diacetyl and Pentane 2,3 dione resides in the generation of aerosols (via a vaporisation system or an electronic cigarette) and the driving of these aerosols to a Diacetyl and Pentane 2,3 dione trapping system: a bubbler containing Ethanol. Then analyze the trapped solutions by GC-MS. Diacetyl 43-03-8 ug/00puffs 0.546 5.46 ND Pentane 2,3 dione 600-4-6 ug/00puffs 0.546 5.46 ND 5. Ethylene Glycol and Diethylene Glycol Method: Products were attached to a smoke machine, and the aerosol was collected in Cambridge filter pads. After trapping and solvent extraction, solution was analyzed by GC-MS and Glycols were dosed by comparing the areas obtained on the MS detector with those of standard solutions prepared in the laboratory under concentration conditions surrounding those of the samples. Ethylene Glycol 07-2- ug/00puffs 0.667 2 ND Diethylene Glycol -46-6 ug/00puffs 0.667 2 ND

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 7 of 9 6. Specific Nitrosamines Method: The vapor was trapped on a Cambridge filter, after addition of an internal standard, the total particulate matter collected on the Cambridge filter was extracted into ammonium acetate solution using a shaker for a period time. The extract was syringe filtered through a 0.45 µm PTFE column directly into an auto sampler vial. The samples are subjected to LC-MS/MS. N-nitrosonornicotine(NNN) 6543-55-8 ug/00puffs 0.004 0.04 ND 4-(N-methylnitrosamino)--( 3-pyridyl)--butanone(NNK) 6409-9-4 ug/00puffs 0.004 0.04 ND

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 8 of 9 7. VOC substances content(s) Method: The principle of collection and trapping of VOC substances resides in the generation of aerosols (via a vaporisation system or an electronic cigarette) and the driving of these aerosols to a VOC substances trapping system: a bubbler containing Methanol. Then analyze the trapped solutions by GC-MS. Toluene 0-88-3 ug/00puffs 0.667 2 ND Benzene 7-43-2 ug/00puffs 0.667 2 ND,3-Butadiene 06-99-0 ug/00puffs 0.667 2 ND Isoprene 78-79-5 ug/00puffs 0.667 2 ND

Report No. : TCT7226C0 Date : Jan. 04, 208 Page No.: 9 of 9 Photo(s) of the sample(s) A9-3SH(tobacco 8mg) *** End of Report *** Remark:This report is considered invalidated without the Special Seal for Inspection of the TCT. This report shall not be altered, increased or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of TCT, this test report shall not be copied except in full and published as advertisement.