JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005

Similar documents
3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

The Physics of Oesophageal Cancer Radiotherapy

20 Prostate Cancer Dan Ash

Bladder and rectum dose estimations on digitized radiographs for vaginal brachytherapy after hysterectomy

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

HDR Brachytherapy: Results and Future Studies in Monotherapy

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

Predicting Maximum Pacemaker/ICD Dose in SAVI HDR Brachytherapy

Evaluation of three APBI techniques under NSABP B-39 guidelines

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Image based Brachytherapy- HDR applications in Gynecological Tumors

3D CONFORMATIONAL INTERSTITIAL BRACHYTHERAPY PLANNING FOR SOFT TISSUE SARCOMA

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Quality management for Breast Brachytherapy.

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

Online in vivo dosimetry in conformal radiotherapies with MOSkin detectors

A new homogeneity index based on statistical analysis of the dose volume histogram

First, how does radiation work?

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

Brachytherapy Planning and Quality Assurance

MEDICAL POLICY. SUBJECT: BRACHYTHERAPY OR RADIOACTIVE SEED IMPLANTATION FOR PROSTATE CANCER POLICY NUMBER: CATEGORY: Technology Assessment

New Technologies for the Radiotherapy of Prostate Cancer

How ICD-10 Affects Radiation Oncology. Presented by, Lashelle Bolton CPC, COC, CPC-I, CPMA

Institute of Oncology & Radiobiology. Havana, Cuba. INOR

Dosimetric comparison of interstitial brachytherapy with multi-channel vaginal cylinder plans in patients with vaginal tumors

IMRT for Prostate Cancer

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Corporate Medical Policy

FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

THE IMPORTANCE OF IMMOBILIZATION AND LOCALIZATION OF GYNECOLOGICAL APPLICATORS IN HIGH DOSE RATE BRACHYTHERAPY TREATMENTS.

Pavel ŠLAMPA, Jana RUZICKOVA, Barbora ONDROVA, Hana TICHA, Hana DOLEZELOVA

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Spinal Cord Doses in Palliative Lung Radiotherapy Schedules

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Comparison of rectal and bladder ICRU point doses to the GEC ESTRO volumetric doses in Cervix cancer

Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators

Radiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments

Non-Invasive Brachytherapy of the Breast

Outline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT)

Chapters from Clinical Oncology

The New ICRU/GEC ESTRO Report in Clinical Practice. Disclosures

I. Equipments for external beam radiotherapy

Evaluation of Normal Tissue Complication Probability and Risk of Second Primary Cancer in Prostate Radiotherapy

A PRACTICAL METHOD TO ACHIEVE PROSTATE GLAND IMMOBILIZATION AND TARGET VERIFICATION FOR DAILY TREATMENT

Dosimetric Analysis Report

INTRODUCTION PATIENT. J. Radiat. Res., 52, (2011)

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

MultiSource. for a higher standard in HDR brachytherapy.

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

Accurate Accurate boost or Simply Accuboost

Definitions. Brachytherapy in treatment of cancer. Implantation Techniques and Methods of Dose Specifications. Importance of Brachytherapy in GYN

PRINCESS MARGARET CANCER CENTRE CLINICAL PRACTICE GUIDELINES GYNECOLOGIC CANCER CERVIX

BLADDER RADIOTHERAPY PLANNING DOCUMENT

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Comparison of two techniques of interstitial pulsed dose rate boost brachytherapy in conservative treatment of breast cancer

Bone HDR brachytherapy in a patient with recurrent Ewing s sarcoma of the acetabulum: Alternative to aggressive surgery

Treatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons


Colorectal Cancer Treatment

Developments in Directional Brachytherapy William Y. Song, PhD, DABR

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

The Evolution of RT Techniques for Gynaecological Cancers in a developing country context

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Subject Index. Androgen antiandrogen therapy, see Hormone ablation therapy, prostate cancer synthesis and metabolism 49

Real-time brachytherapy for prostate cancer implant analysis

Use of imaging systems for patient modeling - PET and SPECT

BRACHYTHERAPY IN HORSES

Do Advances in Radiotherapy Planning Technology Lead to Improved Palliative Radiotherapy?

Gynecologic Vaginal Brachytherapy (Mostly Post-Op Endometrial)

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

Abstract Purpose: Material and methods: Results: Conclusions: Key words: Purpose Address for correspondence:

Corporate Medical Policy

Chapter 2. Level II lymph nodes and radiation-induced xerostomia

biij Initial experience in treating lung cancer with helical tomotherapy

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Rectal dose and toxicity dosimetric evaluation for various beam arrangements using pencil beam scanning protons with and without rectal spacers

Trina Lynd, M.S. Medical Physicist Lifefirst Imaging & Oncology Cullman, AL Tri-State Alabama, Louisiana and Mississippi Spring 2016 Meeting April

Comprehensive and Practical Brachytherapy March 04-8 March 2018, Ljubljana, Slovenia Day 1 Sunday 4 March 2018

Recent proceedings in Brachytherapy Physics

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

MEDICAL POLICY SUBJECT: BRACHYTHERAPY OR RADIOACTIVE SEED IMPLANTATION FOR PROSTATE CANCER

A Study on Dosimetry of Gynaecological Cancer and Quality Assurance of HDR Brachytherapy in BPKMCH, Nepal

Brachytherapy an Overview

Dosimetric impact of cylinder size in high-dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer

TRANS-TASMAN RADIATION ONCOLOGY GROUP INC. Quality Assurance. Treatment Planning Benchmark

GYNECOLOGIC CANCER and RADIATION THERAPY. Jon Anders M.D. Radiation Oncology

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Panel consensus was not to include suggested revision.

Transcription:

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005 Advantages of inflatable multichannel endorectal applicator in the neo-adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy Slobodan Devic, 1,a Té Vuong, 2 and Belal Moftah 1,b Medical Physics Department 1 and Radiation Oncology Department, 2 McGill University Health Centre, Montreal, Quebec H3G 1A4 Canada devic@medphys.mcgill.ca Received 16 July 2004; accepted 3 February 2005 High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to the bladder, rectal wall, prostate, and bone marrow. Our results suggest that a multichannel applicator provides better sparing of the bone marrow by 50%, clinically uninvolved parts of the rectal wall by 70%, and bladder and prostate (in the case of male patients) by 100% in terms of ratio of median doses to critical organ volume for single- and multichannel endorectal applicators. Our results justify the advantage of using a multichannel endorectal brachytherapy applicator as a neo-adjuvant treatment of patients with locally advanced rectal cancer. PACS numbers: 87.53.Jw, 87.53.Tf Key words: endorectal, brachytherapy, dosimetry I. INTRODUCTION High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality in patients with locally advanced rectal cancer. (1) In order to evolve toward a more radical treatment, a method that delivers conformal radiation to the rectal tumor bed while sparing the surrounding normal tissues is highly desirable. In 1998, we initiated a preoperative treatment protocol, based on an HDR- inflatable multichannel endorectal applicator for patients with operable, locally advanced rectal cancer. A high degree of the treatment conformity is desirable, to allow sparing of normal tissues and to improve the patient s quality of life after the treatment. The clinical aspects of the brachytherapy treatment technique were reported elsewhere. (2,3) Palliative HDR-EBT commonly uses a single-channel rigid endorectal applicator that is associated with a significant amount of pain during the insertion, and therefore limits the clinical indications. The rectum curves at a distance of 10 cm from the anal verge, so the use of a rigid applicator (either single- or multichannel) is restricted to clinical indications of tumors below this curve. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The aim of this study was to make a differential quantitative estimation of the expected dose distribution advantage for multichannel versus single-channel endorectal applicators. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to surrounding critical structures, for example, bladder, rectal wall, prostate, and bone marrow. a b Corresponding author: Slobodan Devic, Ph.D., Medical Physics Department, McGill University, Montreal General Hospital, 1650 avenue Cedar, L5-112, Montreal, Quebec H3G 1A4; 514-934-8052 (phone); 514-934-8229 (fax). Current address: Department of Medical Physics, King Faisal Specialist Hospital and Research Center, Jeddah, Kingdom of Saudi Arabia 44 2005 Am. Coll. Med. Phys. 44

45 Devic et al: Advantages of inflatable multichannel... 45 II. MATERIALS AND METHODS In our department, patients with locally advanced rectal cancer were treated on protocol with preoperative HDR brachytherapy, using the Novi Sad (Novi) endorectal applicator (Nucletron Corp., Columbia, MD; Fig. 1). The Novi applicator consists of a central flexible tube with eight catheters arranged around the tube circumference. The applicator also contains a balloontype device, which can be inflated to immobilize the applicator in the desired position within the rectum. The target volume is localized using magnetic resonance imaging. Radio-opaque endorectal clips are endoscopically inserted to mark the proximal and distal margins of the tumor. The treatment planning process commences at the CT simulator with the endorectal applicator adjusted according to the position of the radio-opaque clips. Tumor and catheters are contoured and incorporated into digitally reconstructed radiographs. Digitally composite radiographs and 3D renderings are used to selectively enhance the visualization of bony landmarks as well as the inserted applicator and clips. FIG. 1. Inflatable multichannel endorectal brachytherapy applicator, Novi Sad (Nucletron) For treatment planning, catheters are loaded in a differential manner so that only those in a close proximity to the tumor contain active-source dwell positions. This source-positioning technique allows treatment of semi-circumferential lesions in a conformal manner. Following the initial source position determination, a CT-based brachytherapy treatment planning is performed to fully optimize the dose to the tumor, while limiting the dose to the immediate adjacent healthy tissues and the rectal wall. Dose distribution calculations were performed by a brachytherapy treatment-planning system (Plato, v14.1, Nucletron, MD) for a sequence of CT planes. For 3D dose calculations, this treatment-planning software uses the TG 43 protocol.(4)

46 Devic et al: Advantages of inflatable multichannel... 46 We made a quantitative comparison between plans created with the single-channel (Miami) and multichannel (Novi) applicators. The plans were created so as to produce the same target dose-volume histogram (DVH) curves for both plans, up to the level of the prescription dose, 650 cgy. For 27 patients (9 females, 18 males), we also calculated the DVH curves for the rectal wall, bladder, bone marrow, and prostate (for male subjects). This group of patients was chosen in such a way that the angular spread of the tumor, defined by an angle ϕ (Fig. 2, left), was not larger than 225 on at least two-thirds of the CT slices that contained the outlined tumor volume. This selection was performed because the patients with circumferential lesions would not benefit if treated with a multichannel instead of a single-channel endorectal applicator. The extent of the critical organs was determined in the following way: Each critical organ was initially outlined in its full extent. If the organ was encompassed within slices containing the target volume, the whole organ volume was used for DVH calculations. If, however, the organ extended beyond the level of the target volume, the superior and inferior limits of the critical organ in question were determined as the 10% isodose cloud spread throughout the irradiated volume. This was done with the intention of not biasing the data comparison with the anatomical differences between the patient cohort studied as well as the extent of the tumor within the 3D volume of the CT data. Also, the volume of rectal wall used for DVH calculations was calculated by subtracting the target volume from the outlined rectal wall. FIG. 2. Comparison of dose distributions on the same slice for the rectum cancer treatment using a single-channel (Miami, left) and multichannel (Novi, right) endorectal applicator. The slice shows three isodose lines: 50% (short dashes); 100% (long dashes); and 200% (solid line). The angle ϕ on the left figure defines the angular prevailing of the tumor volume around the rectum. In order to make a quantitative comparison between impacts of dose distributions on critical structure DVHs for the two applicators, we arbitrarily defined a parameter: DMiami ( V = 50%) δ (1) V 50 = DNovi ( V = 50%) which represents a ratio of cumulative doses to a 50% of critical organ volume (median doses). The values D (V = 50%) were read graphically from DVH curves. III. RESULTS AND DISCUSSION Treated tumors were of an average depth of 1.8 cm (range 1 cm to 4 cm) and a mean length of 4.3 cm (range 2 cm to 10 cm). The longest distance of the tumor extent from the anal verge was 15 cm. During the course of treatment, all tumors were accessible by the Novi endorectal applicator, and conformal dosimetry was achievable in all cases.

47 Devic et al: Advantages of inflatable multichannel... 47 Figure 2 represents a comparison of the 2D dose distributions obtained with the Novi applicator (right) and the single-channel Miami applicator (left) on the same CT slice for one representative patient. For all patients, the same CT dataset was used for dose calculation for both Novi and Miami applicators. Positioning the source dwell positions in the middle of the Novi applicator simulated plans with the Miami applicator. Plans for the two applicators and every patient were made to produce the same tumor coverage, for example, an outlined target DVH overlap up to the prescription dose for both plans (Fig. 3(a)). Figure 2 illustrates a better dose distribution conformity when the multichannel applicator is used versus a single-channel endorectal applicator. It also produces a lower dose to the surrounding healthy tissues as well as to the clinically noninvolved part of the rectal wall, while the tumor coverage remains the same. Figure 3 summarizes the DVHs calculated for one representative patient for the target volume as well as for the critical structures (bladder, rectal wall, and bone marrow) using the Miami (solid lines) and the Novi (dashed lines) brachytherapy rectum applicators. Dose-volume histograms for the target volume (Fig. 3(a)) illustrate results of the approach we used in order to provide the same dose coverage to the target volume for both the Novi and the Miami applicators. In addition, Fig. 3(a) indicates that a certain part of the target volume is receiving higher doses when using the Novi applicator. This is because the source dwell positions are closer to the target volume and because of the presence of higher dose gradients obtained with the Novi applicator. On the other hand, the conformal nature of the dose distributions produced with the Novi applicator lead to lower doses to the surrounding critical structures, observed on comparative DVHs. FIG. 3. Cumulative DVHs calculated for the treatment plan (dashed lines, Novi applicator) and simulated plan (solid line, Miami single-channel applicator) for one representative patient for (a) target volume, (b) bladder, (c) rectal wall, and (d) bone marrow. From the DVH curves shown in Fig. 3 one may observe that critical structures will receive doses well below tolerance levels (5) if the patient is treated with either of the two applicators. However, patients found to have positive nodes from pathological specimen after surgery would receive postoperative external beam radiotherapy (45 Gy/25 fractions) to the pelvic region. (3)

48 Devic et al: Advantages of inflatable multichannel... 48 For these patients, improvement in dose conformity and reduction of dose to critical structures (as shown in Fig. 3) will facilitate external beam treatment planning with respect to critical organ dose tolerance restrictions. The ratio of δ V50 for the Miami and the Novi applicator for the cohort of 27 patients is presented in Fig. 4, together with the mean values as well as the corresponding standard errors. It is apparent from Fig. 4 that most dose sparing is obtained for bladder (even more for the prostate structure, but this applies for the male subjects only), while the least effect is observed in the bone marrow case. In the case of the prostate, a relative error of the average δ V50 ratio is 10% in comparison to 4% for the other three critical structures. Statistical significance of the mean for the δ V50 ratio has been calculated based on comparison with the same type of the distribution (having the same standard deviation) centered around the ratio value of 1, using the t-type statistical test. Statistical significances for the ratios obtained in this way are given in parentheses in Fig. 4. Although well below the 0.05 value, statistical significance in the case of prostate is slightly higher than for other critical structures. This is due to the smaller number of patients in the distribution (males only), as well as the higher spread of the observed ratios around the mean. FIG. 4. Ratio of median doses to the critical organ irradiated volume for single-channel (Miami) and multichannel (Novi) applicator for the cohort of 27 patients. For 18 male patients the ratio was determined for the prostate. For every critical structure, we reported mean value of the ratio as well as the corresponding standard error and p-values.

49 Devic et al: Advantages of inflatable multichannel... 49 Results of our numerical comparison, summarized in Fig. 4, have already been tested in phase I/II clinical trial in our department. (3) It was observed that conformal preoperative HDR- EBT for patients with locally advanced rectal carcinoma is well tolerated with Grade 2 moderate proctitis being the main toxicity. Because of the central flexible tube in its current design, the Novi Sad applicator does not allow for the segmental shielding. However, flexibility of the Novi Sad applicator makes it more suitable for clinical applications by allowing its use at distances of more than 10 cm from the anal verge; it also provides more comfort to the patient. IV. CONCLUSIONS The results of this study show that the multichannel brachytherapy endorectal applicator provides better conformity of dose delivery to the target volume while sparing the surrounding critical structures, when compared to the standard single-channel endorectal brachytherapy applicator. The multichannel applicator provides better sparing of the bone marrow by 50%, clinically uninvolved parts of the rectal wall by 70%, and bladder and prostate (in the case of male patients) by 100% in terms of ratio of cumulative doses to a 50% of critical organ volume for single- and multichannel endorectal applicators. Therefore, the selection of a multichannel loading endorectal applicator is of importance in order to achieve conformal radiation delivery in the neo-adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy. References 1. Kaufman N, Nori D, Shank B, et al. Remote afterloading intraluminal brachytherapy in the treatment of rectal, recto sigmoid, and anal cancer: A feasibility study. Int J Radiat Oncol Biol Phys. 1989;17(3):663 668. 2. Vuong T, Devic S, Moftah B, Evans M, Podgorsak EB. High dose rate endorectal brachytherapy in the treatment of locally advanced rectal carcinoma: Technical aspects. Brachytherapy (2005), in press. 3. Vuong T, Belliveau P, Michel R, et al. Conformal preoperative endorectal brachytherapy treatment for locally advanced rectal cancer. Dis Colon Rectum. 2002;45(Oct):1486 1495. 4. Nath R, Anderson LL, Luxton G, Weaver KA, Williamson JF, Meigooni AS. Dosimetry of interstitial brachytherapy sources: Recommendation of AAPM Radiation Therapy Committee Task Group No. 43. Med Phys. 1995;22(2):209 234. 5. Emami B, Lyman J, Brown A, et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys. 1991; 21(1):109 22.