Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on /jp-journals

Similar documents
Palatal Vault Depth Influence on the Flexural Strength of Two Heat Cure Acrylic Denture Base Resins: An in vitro Study

Comparison of Flexural Strength of two Provisional Materials Used In Fixed Prosthodontics -An in Vitro Study.

Study to evaluate the Effect of Silane Treatment and Three Different Woven Fiber Reinforcement on Mechanical Properties of a Denture Base Resin

FRACTURE STRENGTH OF PALATAL DENTURE BASE CONSTRUCTED FROM DIFFERENT ACRYLIC DENTURE BASE MATERIALS

/jp-journals Evaluation of Impact Strength of Conventionally Heat Cured and High Impact Heat Cured Poly Methyl

COMPARISION OF IMPACT STRENGTH IN THREE DIFFERENT TYPES OF DENTURE BASE RESINS AN IN-VITRO STUDY

International J. of Healthcare and Biomedical Research, Volume: 04, Issue: 01, October 2015, Pages 17-25

An Evaluation on the Flexural Strength of Heat Cure Polymethyl methacrylate Denture Base Resin with and without Reinforcement of Polyethylene Fiber

Original Article MATERIALS AND METHODS INTRODUCTION

Evaluation of Bond Strength of Silicone and Acrylic Resin Based Resilient Denture Liners Over A Period of Storage in Water.

Flexural Strength of Poly Propylene Fiber Reinforced PMMA

The Fracture Pattern of Different Mandibular Over Denture Designs.

IJopRD INTRODUCTION ABSTRACT MATERIALS AND METHODS /jp-journals

Transverse Strength of Reinforced Denture Base Resin with Metal Wire and E-Glass Fibers

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

The effect of glass flakes reinforcement on the surface hardness and surface roughness of heat-cured poly (methyl methacrylate) denture base material

Effect of Thickness and Recycling on Transverse Strength of Relined Acrylic Resin Denture

An evaluation of the hardness of flexible Denture Base Resins

@Society of Scientific Research and Studies. Journal home page: doi: /jamdsr UGC approved journal no

"Artless solution to resolve the problem of retention in resorbed alveolar ridge cases"

Original Research. The Effect of temperature on the strength of luting cements Patil SG et al

ISSN (Online) ISSN (Print) Mangalore, Karnataka, India. *Corresponding author Dr. Shilpa.S. Dandekeri

INDIAN DENTAL JOURNAL

Flexural and fatigue strengths of denture base resin

Journal of IMAB - Annual Proceeding (Scientific Papers) 2016, vol. 22, issue 3

Shear Bond Strength of Acrylic Teeth to Acrylic Denture Base after Different Surface Conditioning Methods

Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

Nagri D et al. Linear occlusion and Neutral Zone recording for severely resorbed ridges

AN INJECTION MOULDING DEVICE, IMPROVING THE EXISTING INJECTION SYSTEM FOR ACRYLIC DENTURE FABRICATION

Effect of Notching on Impact Strength of Thermocyclyed Acrylic Resin Denture Base Material

An Obturator With A Soft Touch: A Case Report

ISSN X (Print) Research Article. *Corresponding author Dr. Hemal Agrawal

Natural Tooth Pontic using Fiber-reinforced Composite for Immediate Tooth Replacement

Bond strength test of acrylic artificial teeth with prosthetic base

Effect of Different Dental Materials on the Surface. Roughness of Acrylic Resin ( A comparative in vitro study )

The Effect of Outdoor Weathering on Color Stability of Silicone and Acrylic Resin, Pigments A Comparative Evaluation: An in vitro Study

Impact Strength of Acrylic Denture Base Resin Reinforced with Woven Glass Fiber

Reinforcing Heat-cured Poly-methyl-methacrylate Resins using Fibers of Glass, Polyaramid, and Nylon: An in vitro Study

Original Research. Absorption of soft lining materials Kumar SK et al

Assistant Professor, Department of Prosthodontics, Tamil Nadu Government Dental College & Hospital, Chennai, India. 2

Selection and arrangement of teeth in rpd

Samantha W. Chou, D.M.D N. Southport Ave. Chicago, Illinois Phone: Fax:

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year

Flexural Strength of Three Denture Base Materials in Different Curing Procedures

PROSTHETICREHABILITATION OFAHEMIMANDIBULECTOMY PATIENTWITHTWINOCCLUSION

IvoBase Material. The innovative denture base material. Tissue friendly, tough, predosed

Bending strengths and hardness of autopolymerized acrylic resin

Flexural properties and impact strength of denture base polymer reinforced with woven glass fibers

EFFECT OF THERMOCYCLING ON THE TENSILE AND SHEAR BOND STRENGTHS OF THREE SOFT LINERS TO A DENTURE BASE RESIN

Prosthodontic Rehabilitation with Overdenture Using Modified Impression Technique: A Case Report

Cast Partial Denture Improving Emergence and Masticatory Function - A Case Report

The Effect of Using Modified Flask on the Porosity of Processed Heat- Cure Acrylic Resin

Comparison of fiber reinforcement placed at different locations of pontic in interim fixed partial denture to prevent fracture: An in vitro study

The impact of frenulum height on strains in maxillary denture bases

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

Pre prosthetic surgery

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

International Journal of Clinical And Diagnostic Research ISSN Volume 6, Issue 2, Mar-April 2018

Increasing the Interfacial Adhesion in Poly(methyl methacrylate)/carbon Fibre Composites by Laser Surface Treatment

Component parts of Chrome Cobalt Removable Partial Denture

Occlusion and Attachments

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Short Fiber Reinforced Composite: The Effect of Fiber Length and Volume Fraction

Frequency of the Various Classes of Removable Partial Dentures and Selection of Major Connectors and Direct/Indirect Retainers

Evaluation of bond to Enigma High Impact Denture Base

Rehabilitation of Resorbed Mandibular Ridge with Implant Supported Overdenture- A Clinical Report

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

Evaluation of Impact and Transverse Strength of Denture Bases Repaired with Nano Reinforced Resin

UnBreakable. Arian Deutsch, CDT

JCDP. Original Research ABSTRACT INTRODUCTION

Replacing Lost Happiness

Effect of Fiber Post and Stainless Steel Wire on the Flexural Strength of Repaired Denture Base Acrylic Resin

RELINING AND REBASING

SOLUBILITY OF DIFFERENT SOFT LINING MATERIALS IN DISTILLED WATER, ARTIFICIAL SALIVA AND DENTURE DISINFECTANT SOLUTION

(Images are at the end of article)

Repair of fractured denture bases is an

Experimental and Numerical Comparison of Stresses Level between Titanium and Novel Composite Single Tooth Implant

Short Glass Fiber-reinforced Composite with a Semi-interpenetrating Polymer Network Matrix for Temporary Crowns and Bridges

أ.م. هدى عباس عبد اهلل CROWN AND BRIDGE جامعة تكريت كلية. Lec. (2) طب االسنان

Original Research. Strength of Denture Relining Materials...Lau M et al

1. Peyton FA. History of resin in dentistry. Dent Clin North Am 1975; 19: Phillips RW. Skinner s science of dental materials. 9th ed.

Effect of fiber reinforcement on impact strength of heat polymerized polymethyl methacrylate denture base resin: in vitro study and SEM analysis

1. RPD Acrylic portions = denture teeth (DT), denture base (DB) (and veneering)

Prosthodontic Management of Combination Syndrome Case with Metal Reinforced Maxillary Complete Denture and Mandibular Teeth supported Overdenture

Effect Of Joint Surface Treatment On The Flexural Strength Of Repaired Auto-Polymerized Acrylic Resin.

NUMERICAL STUDY OF STRESSES IN DENTAL MATERIALS BY USING FINITE ELEMENT ANALYSIS

Comparison between Acetal Resin and Cobalt-Chromium. Removable Partial Denture Clasp Retention: An in vitro Study.

TOOTH SUPPORTED MANDIBULAR OVERDENTURE: A FORGOTTEN CONCEPT

Comparison of Fracture Resistance of Cast Post and Core using Different Alloys: An Unexplored Frontier

Artic Posteriors 30 U 30 L 32 U 32 L 30 U 30 L 32 U 32 L 30 U 30 L 32 U 32 L. Jump to Product Item Numbers

CASE REPORT ABSTRACT INTRODUCTION. AIMS AND OBJECTIVES Aims

VIP Partner Laboratory (PL) Process Flow

م.م. طارق جاسم حممد REMOVABLE PARTIAL DENTURE INTRODUCTION

Cementation Prof. Anil Arora MS (Ortho) DNB (Ortho) Dip SIROT (USA) FAPOA (Korea), FIGOF (Germany), FJOA (Japan) Associate Director

Research Article Effect of Different Denture Base Materials and Changed Mouth Temperature on Dimensional Stability of Complete Dentures

Comparative Evaluation of Fracture Resistance of Dental Amalgam, Z350 Composite Resin and Cention-N Restoration In Class II Cavity

Total Rehabilitation Of Poor Edentulous Arches With Metal Denture Bases And Finger Prosthesis.

Prosthetic V. Removable dentures I.

Transcription:

Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on 10.5005/jp-journals-00000-0000 Shallow Palatal Vault Configuration original research Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on Shallow Palatal Vault Configuration: An in vitro Study 1 Swapnil S Jadhav, 2 Pronob K Sanyal, 3 Shivsagar Tewary, 4 Rakshith Guru, 5 Shubha Joshi, 6 Abhijeet Kore ABSTRACT Statement of problem: Single maxillary complete denture fracture along the midline due to crack initiation and propagation from stressed areas in shallow palatal vault configuration. Therefore, it is important to use mesh in single denture fabrication. Aims and objectives: To investigate the mechanical fracture strength of acrylic resin denture base materials using four different mesh designs on shallow palatal vault configuration. Materials and methods: One type of heat-cured resin denture base materials was used to fabricate specimens. Shallow palatal vault shape stainless steel mold was used to aid in duplicating and standardizing the samples. A total of 100 samples were fabricated with high-impact acrylic resin denture base material using shallow palatal vault configuration and square mesh of dimension 50 40 mm was used and samples were divided into 5 groups of 20 samples, and each group contained different mesh designs. These samples were stored in water at room temperature for 4 weeks and will be subjected to fracture test using universal testing machine. Results: Samples with different four mesh designs, among them there was no significant difference, but fracture strength value of 4 4 mm mesh design was slightly more than other groups. Conclusion: The shallow palatal vault denture base is inherently weaker and less resistant to fracture. Thus, it is recommended to use stainless steel metal mesh in shallow palatal vault to increase fracture resistance. As there was no statistical difference among different mesh designs (i.e., different dimensions of each square in the mesh), any dimension of each square in the mesh can be used without making much statistical difference. Keywords: Denture base, Fracture strength, Heat cure acrylic resins, Metal mesh, Palatal vault. 1 Postgraduate Student, 2 Professor and Head, 3,5,6 Reader 4 Professor 1-6 Department of Prosthodontics, School of Dental Sciences Krishna Institute of Medical Sciences Deemed University, Karad Maharashtra, India Corresponding Author: Swapnil S Jadhav, Postgraduate Student, Department of Prosthodontics, School of Dental Sciences Krishna Institute of Medical Sciences Deemed University, Karad Maharashtra, India, e-mail: swapnilj2874@gmail.com How to cite this article: Jadhav SS, Sanyal PK, Tewary S, Guru R, Joshi S, Kore A. Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on Shallow Palatal Vault Configuration: An in vitro Study. Int J Prev Clin Dent Res 2017;4(3):1-9. Source of support: Nil Conflict of interest: None INTRODUCTION The material most commonly employed in the construction of dentures is poly methylmethacrylate (PMMA) resin. Despite its popularity in satisfying esthetic demands, it is not very ideal in fulfilling the mechanical requirements of prosthesis. This is reflected in unresolved problem of denture fracture and accompanying costs to effect repair. 1 During function, the denture base is subjected to various stresses like compressive, tensile and shear stress leading to denture fracture. In order to withstand these stresses, the denture base should possess good mechanical properties. One of the important properties is fracture strength. It is the stress at which a brittle material fractures. A number of predisposing factors have been recognized for the incidence of denture fractures. These include unsatisfactory occlusion, poor fit of the prosthesis, deep frenal notches, sharp changes in the contour of denture bases, and single complete denture. 2 However, denture base resins in single complete dentures have been frequently found to fracture under excess masticatory forces. So a single complete denture opposing natural dentition should be reinforced to that extent that it should withstand the huge occlusal forces acting on it. Metal can be added in form of wires, bars, mesh, or plates. Metal strengthener had a beneficial effect on the fracture resistance of the PMMA. All forms of metal reinforcement significantly increased the impact strength, fracture strength, and tensile strength. 3 In the prosthodontic literature, palatal shapes have been classified according to their cross-arch forms. Generally, palatal vault of various configurations can be classified into three groups as suggested by Johnson and Mathews, 3 viz.,. shallow, medium, deep. Saraf et al 4 found that maximum fracture of maxillary denture was seen in shallow palatal vault configuration. International Journal of Preventive and Clinical Dental Research, July-September 2017;4(3):1-9 1

Swapnil S Jadhav et al In case of maxillary denture, palatal vault shape may influence the fracture strength of heat-polymerized acrylic resin denture base. Several studies have focused on attempts to improve the mechanical properties of PMMA. Numerous techniques for reinforcement of PMMA with inclusion of other materials have been described like inclusion of metals, mesh, hydroxyapatite, and rubber fillers in heat-cured MMA increased the fracture toughness when compared with commercial denture base material. 5 So in this study, stainless steel metal mesh is used which is popular and cost-effective to increase fracture strength of PMMA. OBJECTIVES To evaluate the mechanical strength in fracture test of shallow palatal vault heat cure denture bases without incorporating mesh. To evaluate the mechanical strength in fracture test of shallow palatal vault heat cure denture bases incorporating mesh of four different dimensions. To compare the mechanical strength in fracture test of shallow palatal vault heat cure denture bases with and without incorporating mesh. To compare the mechanical strength in fracture test of shallow palatal vault heat cure denture bases incorporating mesh of four different dimensions. MATERIALS Heat cure acrylic resin DPI Heat cure (Dental Products of India Ltd), Mumbai. Prefabricated stainless steel mesh material (mainly contains chromium 18% and nickel l8%) COMDENT CORPORATION, Mumbai, Maharashtra. Petroleum jelly Vaseline, Made in India, manufactured by Cool Cosmetics Pvt, Ltd. METHODS Preparation of Specimen Single type of heat-cured resin denture base material (DPI Heat cure) was used to fabricate specimens in a steel split mold. Shallow palatal vault shape stainless steel split mold was used and the dimension of steel split mold = 50 mm 40 mm 9 mm (Length Breadth Depth). The stainless steel mold was fabricated at MIDC, Koyanavasahat, Karad, India, to aid in duplicating and standardizing the samples (Figs 1A to C). A B C Figs 1A to C: Steel split mold with clamp 2

Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on Shallow Palatal Vault Configuration Samples in each group (n = 20) for group I (control group without incorporating mesh) were prepared individually in following manner. A monomer polymer ratio of 1:3 by volume for all samples was used. A pipette was used to transfer the required volume of monomer to a clean, dry, porcelain mixing jar. A measured quantity of polymer was transferred to the mixing jar containing monomer. Thorough mixing was done with a clean stainless steel spatula. The jar was kept closed till the mix attained the dough stage. The resin dough was removed from the mixing jar and loaded in stainless steel split mold. Then stainless steel split mold was reassembled and bench pressed under 1500 psi until the edges of the steel split mold closely approximated one another (Figs 2A and B). The stainless steel split mold was clamped and kept overnight for bench curing. A short curing cycle was employed to cure the specimens. The acrylizer was filled with water. The clamped steel split mold was submerged in water at room temperature (23 ± 2 C). First, the temperature of the water was raised to 74 C for 1½ hour. Later the temperature of the water bath was maintained at boiling/100 C for an additional 1 hour. On cooling, the specimens were removed from the mold. Excess acrylic resin was removed, finishing and polishing was done, and named as Group I (control group without incorporating mesh) (Figs 2A and B). Samples for groups II V (n = 80) (with incorporating mesh) were prepared individually in following manner four different dimensions of mesh were used. They were adapted on the mold by keeping under hydraulic bench press under 1500 psi pressure to get the shape of shallow palatal vault (Figs 2C and D), then similar procedure used for fabrication of samples of group I was repeated to prepare samples which were incorporated with mesh of different dimensions and were named as groups II V accordingly. Sample Size A total of 100 samples were fabricated with high-impact acrylic resin denture base material using shallow palatal vault configuration. These samples were divided into five groups of 20 samples. Group I: 20 shallow palatal vault fabricated with highimpact acrylic resin denture base material without using mesh (Fig. 3A). Group II: 20 shallow palatal vault fabricated with high-impact acrylic resin denture base material using mesh of dimension 50 40 mm (Length Breadth) containing squares and each square had dimension 1 mm 1 mm (Length Breadth) (Fig. 3B). Group III: 20 shallow palatal vault fabricated with highimpact acrylic resin denture base material using mesh of dimension 50 mm 40 mm (Length Breadth) containing squares and each square had dimension 2 mm 2 mm (Length Breadth) (Fig. 3C). Group IV: 20 shallow palatal vault fabricated with high-impact acrylic resin denture base material using mesh of dimension 50 mm 40 mm (Length Breadth) containing squares and each square had dimension 3 mm 3 mm (Length Breadth) (Fig. 4A). Group V: 20 shallow palatal vault fabricated with high-impact acrylic resin denture base material using mesh of dimension 50 mm 40 mm(length Breadth) containing squares and each square had dimension 4 mm 4 mm (Length Breadth) (Fig. 4B). These samples were stored in distilled water at room temperature for 4 weeks. Later, samples were subjected to fracture test using Universal Testing Machine (UTM). A B Testing Procedure Samples were dried completely before placing them on the UTM. The samples were kept with the tissue side, i.e., the unpolished surface on the platform of the UTM (Fig. 5). The fracture tests were carried out on UTM at a cross-head speed of 5 mm/minute. Force was applied via a specially profiled metal ring placed on the most prominent part of the palate. The readings were collected as data. The data were statistically analyzed. C D Figs 2A to D: Packing and mesh adaptation RESULTS Table 1 gives descriptive statistics for fracture strength of all the five groups with force of minimum 840.16 N International Journal of Preventive and Clinical Dental Research, July-September 2017;4(3):1-9 3

Swapnil S Jadhav et al A B C Figs 3A to C: Fabricated samples and maximum of 1120.48 N. The mean force required with or without mesh was 1043.1485 N with standard deviation of 70.11566 N. Table 2 and Graph 1 describe statistics [mean ± standard deviation (SD)] for fracture strength among five groups. Control group with force of minimum 840.16 N and maximum of 1054.72 N, the mean force required without mesh was 938.55 N with standard deviation of 75.80 N. Shallow palatal vault heat cure denture base with mesh containing each square of dimension 1 1 mm requires force minimum of 1024.88 N and maximum of 1099.50 N, the mean force required to fracture shallow palatal vault heat cure denture base with mesh containing each square of dimension 1 1 mm was 1066.66 N with standard deviation of 31.43 N shallow palatal vault heat cure denture base with mesh containing each square of dimension 2 2 mm requires force minimum of 1019.16 N and maximum of 1082.09 N, the mean force required with mesh containing each square of dimension 2 2 mm was 1046.56 N with standard deviation of 27.73 N. Shallow palatal vault heat cure denture base with mesh of dimension containing each square of 3 3 mm requires force minimum of 1014.93 N and maximum of 1114.43 N, the mean force required to fracture shallow palatal vault heat cure denture base with mesh containing each square of dimension 3 3 mm was 1078.4815 N with standard deviation of 35.65 N. Shallow palatal vault heat cure denture base with mesh of dimension containing each square of 4 4 mm requires force minimum of 1020.10 N and maximum of 1120.48 N, the mean force required 4

Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on Shallow Palatal Vault Configuration A B Figs 4A and B: Fabricated samples Fig. 5: Sample on UTM Graph 1: Mean fracture strength among five groups Table 1: Descriptive statistics (mean ± SD) for fracture strength among study Descriptive statistics n Minimum Maximum Mean Std. deviation Fracture strength 100 840.16 1,120.48 1,043.1485 70.11566 with mesh containing each square of dimension 4 4 mm was 1085.47 N with standard deviation of 39.12 N. Table 3 shows the mean fracture strength among five groups was compared by analysis of variance (ANOVA) which found to be statistically significant (p < 0.001) with F 35.284. This means there was difference in mean strength among all five groups. Table 4 shows the mean difference for fracture strength among group I (938.5525 ± 75.80340) and groups II V (1066.6670 ± 31.43508) was 128.11450 with standard error (SE) 14.35664 which was statistically significant p < 0.001, confidence interval (CI) ( 168.0384; 88.1906). The mean difference for fracture strength among groups II V was statistically insignificant p > 0.005. It denoted there was a significant (p < 0.05) difference in the fracture strength of denture bases in the fracture strength of shallow palatal vault heat cure denture bases with mesh and without mesh and no statistical difference among different mesh designs (i.e., different dimensions of each square in the mesh) but there was slight difference in the fracture strength values of shallow palatal vault heat cure International Journal of Preventive and Clinical Dental Research, July-September 2017;4(3):1-9 5

Swapnil S Jadhav et al Table 2: Descriptive statistics (mean ± SD) for fracture strength among five groups Descriptive statistics Groups n Minimum Maximum Mean Std. deviation I (control without mesh) 20 840.16 1,054.72 938.5525 75.80340 II (with mesh 1*1) 20 1,024.88 1,099.50 1,066.6670 31.43508 III (with mesh 2*2) 20 1,019.16 1,082.09 1,046.5695 27.73605 IV (with mesh 3*3) 20 1,014.93 1,114.43 1,078.4815 35.65255 V (with mesh 4 4) 20 1,020.10 1,120.48 1,085.4720 39.12728 Table 3: Comparing mean fracture strength among five groups by one-way ANOVA Analysis of variance Fracture strength Sum of squares Df Mean square f-value Sig. Between groups 290,896.917 4 72,724.229 35.284 <0.001 Within groups 195,807.497 95 2,061.132 Total 486,704.414 99 Table 4: Group-wise comparison of mean fracture strength among five groups (one to one ) by Tukey s post hoc test Multiple comparisons Dependent variable: fracture strength Tukey honest significant difference (I) group (J) group Mean difference (I J) Std. error Sig. 95% CI Lower bound Upper bound Group I (control without mesh) Group II (with mesh 1*1) 128.114 * 14.356 <0.001 168.03 88.1906 Group I (control without mesh) Group III (with mesh 2*2) 108.017 * 14.356 <0.001 147.94 68.0931 Group I (control without mesh) Group IV (with mesh 3*3) 139.929 * 14.356 <0.001 179.85 100.005 Group I (control without mesh) Group V (with mesh 4*4) 146.919 * 14.356 <0.001 186.84 106.995 Group II (with mesh 1*1) Group III (with mesh 2*2) 20.0975 14.356 0.629 19.826 60.0214 Group II (with mesh 1*1) Group IV (with mesh 3*3) 11.8145 14.356 0.923 51.738 28.1094 Group II (with mesh 1*1) Group V (with mesh 4*4) 18.8050 14.356 0.686 58.728 21.1189 Group III (with mesh 2*2) Group IV (with mesh 3*3) 31.9120 14.356 0.180 71.835 8.0119 Group III (with mesh 2*2) Group V (with mesh 4*4) 38.9025 14.356 0.060 78.826 1.0214 Group IV (with mesh 3*3) Group V (with mesh 4*4) 6.9905 14.356 0.988 46.914 32.9334 *The mean difference is significant at the 0.05 level denture base with mesh and it was seen that fracture strength value of shallow palatal vault heat cure denture base containing mesh of dimension 4 4 mm was more as compared with other groups. The mean fracture strength among five groups was compared by ANOVA which found to be statistically significant (p < 0.001) with F 35.284. This means there was difference in mean strength among all five groups. The mean difference for fracture strength among group I (938.5525 ± 75.80340) and groups II V (1066.6670 ± 31.43508) was 128.11450 with SE 14.35664, which was statistically significant p < 0.001 (CI 168.0384; 88.1906). The mean difference for fracture strength among groups II V was statistically insignificant, p > 0.005 *Statistically significant Significant Figures Suggestive significance, p < 0.05; Moderately significant, p = 0.05; Highly significant, p = 0.01 Statistical Software The statistical software namely Statistical Package for the Social Sciences 20.2 and Systat 8.0 were used for the analysis of the data and Microsoft Word and Excel have been used to generate graphs, tables, etc. DISCUSSION Poly methylmethacrylate has been established as principal material in denture base construction due to its good overall processing as well as user-friendly properties. Nevertheless it is generally recognized that despite fulfilling esthetic requirements, the fracture strength of PMMA are not entirely satisfactory and this is reflected by the expenditure on a large number of denture repairs annually. 6 The denture base is subjected to load during function as well as parafunction. Under the load, the maximum stress is on the palatal aspect of the denture base. Factors that contribute to the stress concentrations will enable the 6

Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on Shallow Palatal Vault Configuration initiation and propagation of the cracks thereby influencing the rate of failure. 7 The morphology of edentulous maxilla greatly influences the manner of deformation of the denture base at the anterior palatal part, an area known to deform most in maxillary dentures. 8 Denture base deformation is also considered to be a contributing factor in ridge resorption, with acrylic resin bases exhibiting a lateral deformation some 8.5 times greater than that of metal denture bases. Denture base deformation is affected by the anatomy of supporting tissues, with high-ridge bases exhibiting torsional deformation and compression (inward movement) occurring with flat ridges. 9 The flexural strength of maxillary denture bases in different palatal vault shapes with varying thickness of denture base was studied by Morris. It was shown that the shape of the palatal vault and the base thickness significantly affect the fracture resistance of denture bases. The shallow palatal vault base is inherently weaker and less resistant to fracture than medium palatal vault and deep palatal vault, a study done by Saraf et al. 4 The stresses to which a denture base is subjected are complex. So in our study, samples included were shallow palatal vault denture base with Stainless steel mesh in order to increase its fracture resistance. Increase in the base thickness will increase the fracture resistance of the shallow palatal vault base, but greater thickness, namely 4 mm may not be clinically acceptable. 10 In this research, 2 mm thickness of denture bases was tested because it is clinically acceptable. The samples were stored in water for 4 weeks. This long period of storage in water allowed any residual monomer to fully leach out. 11 Each sample was then subjected to loading on a UTM. Force was applied via a specially profiled metal ring placed on the most prominent part of the palate at a cross head speed of 5 mm/minute to enable accurate assessment of the actual point of load at which fracture occurred. The testing conditions did not completely simulate the intraoral conditions as force was unidirectional and not multidirectional as seen in the oral cavity. The occlusal scheme was not taken into consideration, which may play a role in the amount of stress applied on the denture base. The readings were collected as data. The data were statistically analyzed. Table 1 gives descriptive statistics for fracture strength of all the five groups with force of minimum 840.16 N and maximum of 1120.48 N. The mean force required with or without mesh was 1043.1485 N with standard deviation of 70.11566 N. Table 2 describes statistics (mean±sd) for fracture strength among five groups. Control group with force of minimum 840.16 N and maximum of 1054.72 N, the mean force required to fracture shallow palatal vault heat cure denture base without mesh was 938.55 N with standard deviation of 75.80 N. Shallow palatal vault Heat cure denture base with mesh containing each square of dimension 1 1 mm requires force minimum of 1024.88 N and maximum of 1099.50 N, the mean force required with mesh of dimension containing each square of 1 1 mm was 1066.66 N with standard deviation of 31.43 N. Shallow palatal vault heat cure denture base with mesh containing each square of dimension 2 2 mm requires force minimum of 1019.16 N and maximum of 1082.09 N, the mean force required to fracture shallow palatal vault heat cure denture base with mesh of dimension containing each square of 2 2 mm was 1046.56 N with standard deviation of 27.73 N. Shallow palatal vault heat cure denture base with mesh of dimension containing each square of 3 3 mm requires force minimum of 1014.93 N and maximum of 1114.43 N, the mean force required to fracture shallow palatal vault heat cure denture base with mesh containing each square of dimension 3 3 mm was 1078.4815 N with standard deviation of 35.65 N. Shallow palatal vault heat cure denture base with mesh containing each square of dimension 4 4 mm requires force minimum of 1020.10 N and maximum of 1120.48 N, the mean force required to fracture shallow palatal vault heat cure denture base with mesh of dimension containing each square of 4 4 mm was 1085.47 N with standard deviation of 39.12 N. It denotes that fracture strength of shallow palatal vault heat cure denture base without mesh had lower as compared with shallow palatal vault heat cure denture base with mesh of different dimensions and it gives slight difference in the fracture strength values within the group of shallow palatal vault heat cure denture base with mesh containing each square of dimension 1 1 mm, 2 2 mm, 3 3 mm, 4 4 mm. Table 3 shows that the mean fracture strength among five groups was compared by ANOVA which was found to be statistically significant (p < 0.001) with F 35.284. This means there was difference in mean strength among all five groups. Table 4 shows that the mean difference for fracture strength among group I (938.5525 ± 75.80340) and groups II V (1066.6670 ± 31.43508) was 128.11450 with SE 14.35664 which was statistically significant p < 0.001, CI 168.0384; 88.1906. The mean difference for fracture strength among groups II V was statistically insignificant, p > 0.005. It denoted that there was a significant (p < 0.05) difference in the fracture strength of denture bases in the fracture strength of shallow palatal vault heat cure denture bases with mesh and without mesh and no statistical difference among different mesh designs International Journal of Preventive and Clinical Dental Research, July-September 2017;4(3):1-9 7

Swapnil S Jadhav et al (i.e., different dimensions of each square in the mesh) but there was slight difference in the fracture strength values of shallow palatal vault heat cure denture base with mesh and it was seen that fracture strength value of shallow palatal vault heat cure denture base containing mesh of dimension 4 4 mm was slightly more compared with other groups. The stainless steel mesh used in study was of different designs (of four dimensions). Further, I have compared mechanical strength of palatal denture base by using these four mesh designs on shallow palatal vault configuration. The present study showed that there was significant difference in the fracture strength of shallow palatal vault denture bases with mesh and without mesh similar to said by, Dahiya et al 3 and Varghese et al. 12 Samples with different four mesh designs containing mesh of different dimensions of each square were 1 1 mm, 2 2 mm, 3 3 mm, 4 4 mm; among them, there was no significant difference, but its values show slight difference as group II (1 1 mm) mean fracture strength 1066.6670 N, group III (2 2 mm) mean fracture strength 1046.5695 N, group IV (4 4 mm) 1085.4720 N, by these values. It is clear that using mesh design containing each square of dimension 4 4 mm had slightly good strength as compared with other groups. According to the subject of structural engineering, as the slenderness ratio increases, the compressive strength decreases. Hence, the strength is inversely proportional 13 (ג) to the slenderness ratio 8 slenderness (ג) ratio = Le/k Le Effective length of sample k Radius of gyration of sample To get values of Le and k, Eulers formula is used. 13 Our study fulfills the assumptions of Eulers theory, such as loading should be given axially to sample, sample material should be elastic and homogenous so that we can use this formula. Using this formula, the slenderness ratio values for groups II V are 1.7460, 1.7450, 1.7440, and 1.7320 respectively. Hence, as the slenderness value for group V is less than the other groups, it proves the statement that the compressive strength of group V is slightly more than the other groups. Very little or no literature available on the comparison of fracture strength of shallow palatal vault denture bases containing mesh, so our hypothesis was incorporating mesh in denture bases strengthens the denture base but using different mesh designs does not make such difference for increasing the strength of denture base but heat cure denture base with mesh containing each square of dimension 4 4 mm had slightly good strength than other groups so we suggest that using mesh containing each square of dimension 4 4 improves strength and esthetics. Midline fractures appear to be the most common problem in maxillary complete dentures, and they can be prevented by reinforcement of the base material. 14 Results indicate that there exists a significant (p < 0.05) difference in the fracture strength of denture bases in the fracture strength of shallow palatal vault denture bases with mesh and without mesh. As there was no statistical difference among different mesh designs (i.e., different dimensions of each square in the mesh), any dimension of each square in the mesh can be used but as there was slight difference in the value of strength of mesh design containing each square of dimension 4 4 mm, mesh containing each square of dimension 4 4 mm is preferred. LIMITATIONS OF THE STUDY The testing conditions did not completely simulate the intraoral conditions as force was unidirectional and not multidirectional as seen in the oral cavity. The occlusal scheme was not taken into consideration, which may play a role in the amount of stress applied on the denture base. We have not discussed about midline fracture of maxillary complete denture. CONCLUSION The shallow palatal vault denture base is inherently weaker and less resistant to fracture hence, recommended to use stainless steel metal mesh in shallow palatal vault to increase fracture resistance. As fracture strength value of mesh design containing each square of dimension 4 4 mm was more as compared with other mesh designs, mesh containing each square of dimension 4 4 mm is advised. REFERENCES 1. Hedzelek W, Gajdus P. Comparison of mechanical strength of palatal denture bases made from various plastic materials. Int J Prosthodont 2006 Mar-Apr;19(2):193-194. 2. Johnson W, Mathews E. Fatigue studies on some dental resins. Br Dent J 1949 May 20;86(10):252. 3. Dahiya D, Thukral H, Rathwa R. Metal reinforced single complete denture: a case report. Int J Enhanc Res Med Dent Care 2016 May;3(5):1-4. 4. Saraf VR, Shetty V, Anandakrishna GN, Rairam RG. Comparison of mechanical strength of palatal denture bases made from three commercially available high impact acrylic resin denture base materials in different palatal vault configurations an in vitro study. J Oral Health Res 2013 Jan; 4(1). 5. Powers JM, Sakaguchi RL. Craig s restorative dental materials. 12th ed. St. Louis (MO): Mosby. p. 59. 6. Jagger DC, Harrison A, Jandt KD. The reinforcement of dentures. J Oral Rehabil 1999 Mar;26(3):185-194.

Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on Shallow Palatal Vault Configuration 7. Mathew E, Wain EA. Stresses in denture base. Br Dent J 1956;100:167. 8. el Ghazali S, Glantz PO, Strandman E, Randow K. On the clinical deformation of maxillary complete dentures influence of denture-base design and shape of denture bearing tissue. Acta Odontol Scand 1989 Apr;47(2):69-76. 9. Beyli MS, von Fraunhofer JA. An analysis of causes of fracture of acrylic resin dentures. J Prosthet Dent 1981 Sep;46(3): 238-241. 10. Morris JC, Khan Z. Palatal shape and the flexural strength of maxillary denture bases. J Prosthet Dent 1985 May;53(5):670-673. 11. Stafford GD, Huggett R. Creep and Hardness testing of some denture base polymers. J Prosthet Dent 1978 Jun;39(6): 682-687. 12. Varghese K, Joy AK, Sankar N, Vaidyan S. A novel method of reinforcing acrylic denture a case report. IOSR J Dent Med Sci 2015 Sep;14(9):50-53. 13. Chen WF, Lui EM. Textbook of structural engineering. 2nd ed. CRC Press; 2005. 14. Karacaer O, Dogan OM, Tinçer T, Dogan A. Reinforcement of maxillary dentures with silane-treated ultra high modulus polyethylene fibers. 2001 Jun;43(2):103-107. International Journal of Preventive and Clinical Dental Research, July-September 2017;4(3):1-9 9