BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

Similar documents
BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

Overview. ACR Accreditation Update in Mammography. New ACR Activities. Requirements Today. What s New For Tomorrow. ACR: Recognized by FDA and CMS

Overview. ACR Update on FFDM Accreditation. New ACR Activities. QC Today. QC Tomorrow. ACR Breast Imaging Centers of Excellence BICOE

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Q. Where can I find out if my state currently requires stereotactic breast biopsy accreditation?

Mammography Quality Control: A Refresher

AAPM Annual Meeting. ACR Accreditation Update in CT

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Implementation of a New Tomosynthesis Program: A Physicists Perspective

CT Quality Control Manual FAQs

Disclosures. Outline. Learning Objectives. Introduction. Introduction. Stereotactic Breast Biopsy vs Mammography: Image Quality and Dose.

Update on MQSA and Mammography Accreditation

The American College of Radiology Breast Ultrasound Accreditation Program: Frequently Asked Questions (Revised: July 31, 2017)

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

ACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program

Hands-On Ultrasound Physics and Quality Control Workshop. Outline

The American College of Radiology Digital Mammography QC Manual: Frequently Asked Questions (Revised 12/12/2018; new and updated items in red)

Hong Kong College of Radiologists Mammography Statement

Debbie Childs RDMS, RVT Sonographer Murphy Medical Center Murphy, NC

ACR MRI Accreditation: Medical Physicist Role in the Application Process

Update on the ACR FFDM QC Manual

Radiation Dosimetry in Digital Breast Tomosynthesis. March, 2015 William J. O Connel, Dr. Ph, Senior Medical Physicist

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Outline. QA/QC of Ultrasound Imagers: Basic Physics, Procedures and Experiences. Frame Rate Limitation. US Imaging Range Equation.

Routine Quality Assurance Cookbook

Dosimetry in digital mammography

Current Ultrasound Quality Control Recommendations and Techniques

HISTORY OF MQSA AND ACR

Dental Extraoral X-ray Systems

PhD Title: Improving QA/QC in mammography screening and breast in Montenegro

Medical Diagnostic Imaging

Ultrasound Accreditation and Regulatory Compliance from A to Z

Quality Control in Mammography: Results from a study in Recife, Brazil. H. J. Khoury, V. S. de Barros, M. Sampaio

Computed tomography Acceptance testing and dose measurements

The Radiology Aspects

NONE. Disclosures. Accreditation Update

MR QA/QC for MRgRT. Rick Layman, PhD, DABR Department of Radiology July 13, 2015

Dental Intraoral X-ray Systems

MQSA Physicist Qualifications. Jon J. Erickson, Ph.D., DABR

Multicenter Trial, Phase I Assessment of 2-D FFDM Versus Combo of 2-D and 3-D Tomosynthesis in Breast Cancer Screening

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRAINING PHANTOMS

Ultrasound Accreditation Program Requirements

Prepublication Requirements

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

IAEA TECDOC 1517 Quality Control in Mammography Software

Radiographic techniques in screen-film mammography

ACR Accreditation Toolkit for Validation Site Surveys

POSITIONING ACR REQUIREMENTS IMAGE REVIEW CATEGORIES DEFICIENCIES IN POSITIONING ACR REQUIREMENTS 3/28/2016 NUMBER 1 REASON FOR ACR FAILURE

-Ray Producing Equipment

Maintaining a quality mammography facility: Overview of ACR and MQSA Requirements and Update on BI-RADS 5 TH Edition

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

Patient Dosimetry in Mammography and Tomosynthesis:

Breast Imaging Essentials

2001 AAPM Summer School Seattle, Washington ACR R/F Phantom

Bone Densitometry Equipment Operator

Accreditation Case Review: Mammography and Stereotactic Biopsy

Low Dose CT Lung Screening: What is Technically Required?

MAMMOGRAPHY QC: MORE THAN PHANTOM IMAGES. Stephanie Schofield RTR QC Technologist Nova Scotia Health Authority

CT Low Dose Lung Cancer Screening. Part I. Journey to LDCT LCS Program

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Steven Tate Nicholas

Using Monte Carlo Method for Evaluation of kvp & mas variation effect on Absorbed Dose in Mammography

Examination of dose evaluation method for mammography: comparison of ACR, Euref and IAEA

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

Quality Control Program Of Real Time Medical Ultrasound Machines In Sudan

Example 1: How would you evaluate this transducer? What is the most common problem found in ultrasound QC testing? Uniformity is Subjective

Medical Physics in the Breast Screening Programme Kath Schofield & Anne McCurrach NSS Medical Physics

Mammographic Accreditation Phantom

Effects of Quality Assurance Regulatory Enforcement on Performance of Mammography Systems: Evidence From Large- Scale Surveys in Taiwan

Fetal Dose Calculations and Impact on Patient Care

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

A tissue-equivalent phantom series for mammography dosimetry

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

Mammograms Obtained with Rhodium vs Molybdenum Anodes: Contrast and Dose Differences

icat Precise Policy and Procedure Manual

Breast dosimetry system in screen/film mammography

Testing of the Implementation of the Code of Practice on Dosimetry in X-ray Diagnostic Radiology Hungarian Contribution

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Establishing a quality assurance baseline for radiological protection of patients undergoing diagnostic radiology

1. Introduction. 2. Technical procedures

Module Rhodes

X-Ray & CT Physics / Clinical CT

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

UPMC 1 Delineation of Privileges Request Criteria Summary Sheet

Radiation Physics Consultants, Inc. Medical Physicist. Mammography Qualifications, Continuing Experience and Continuing Education

BREAST DOSE SURVEYS IN THE NHSBSP: SOFTWARE AND INSTRUCTION MANUAL Version 2.0

Mean glandular dose values used for the mammography screening program in Poland according to the type of image registration system

Introduction and Background

ACR Accreditation Update in MRI

CURRENTLY FDA APPROVED ARE FULL FIELD DIGITAL MAMMOGRAPHY SYSTEMS AND FILM SCREEN STILL BEING USED AT SOME INSTITUTIONS

History of MQSA ACR creates testing procedures Oct Mammography Quality Standards Act Dec 1993 Interim Regulations Oct All mammog

Direct half value layer measurements in mammography - is near enough good enough?

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Introduction 1. Executive Summary 5

PATIENT DOSES FROM SCREEN-FILM AND FULL-FIELD DIGITAL MAMMOGRAPHY IN A POPULATION BASED SCREENING PROGRAMME

Transcription:

BICOE Breast Imaging Center of Excellence What is it? - Requirements William Geiser, MS DABR Senior Medical Physicist MD Anderson Cancer Center Houston, Texas wgeiser@mdanderson.org ACR Accreditation in: Mammography ACR or State Accreditation Stereotactic Breast Biopsy Ultrasound Must include ultrasound guided breast biopsy 1 2 What do you get? National Mammography Database Free participation in the National Mammography Database (NMD) Marketing tools National Recognition Receive routine medical audit reports that exceed FDA audit data collection requirements (Examples: Sample Facility Report Sample Physician Report) Compare performance to peer facilities Target specific areas of improvement Implement successful quality improvement programs Ref: http://www.acr.org/accreditation/bicoe/nmd-participation.aspx 3 4 1

Physicists Role Physicists Role Mammography Accreditation Annual testing (required) QC Program Review (required) Dose Measurement (required) Ultrasound Accreditation Semi-annual testing by service engineer or physicist Stereotactic Breast Biopsy Accreditation Annual Testing (required) QC Program Review (required) Dose Measurement (required) 5 6 MQSA Physicist Stereotactic Breast Biopsy Physicist Initial Requirements Continuing requirements Initial Qualifications Qualified to perform Mammography surveys under MQSA Perform one (1) hands on survey of a stereotactic breast biopsy unit under a QMP or at least 3 independent surveys prior to 6/1/97 Continuing Experience Upon renewal 2 SBB surveys over a 24 month period Continuing Education Upon renewal 3 CEU s in SBB every three years Ref: http://www.acr.org/accreditation/stereotactic/stereotactic_breast_reqs.aspx 7 8 2

What are the minimum continuing experience requirements for the physicist performing stereotactic breast biopsy system surveys for the ACR Accreditation program? 1. 1 stereotactic breast biopsy survey over a 12 month period 2. 2 stereotactic breast biopsy surveys over a 24 month period 3. 3 stereotactic breast biopsy surveys over a 24 month period 4. 3 stereotactic breast biopsy surveys over a 36 month period 5. 4 stereotactic breast biopsy surveys over a 36 month period Answer 2. 2 stereotactic breast biopsy surveys over a 24 month period Ref: Stereotactic Breast Biopsy Program Requirements: American College of Radiology http://www.acr.org/accreditation/stereotactic.aspx 10 9 10 Ultrasound - Physicist Stereotactic Breast Biopsy Program Requirements No requirements yet! Quality Assurance Questionnaire Test Image Data Sheet Dosimeter Clinical Images (on film) Phantom Images (on film) Medical Physicists Annual Survey Report Daily, Weekly Tech QC (one month) Monthly Quarterly, Semi-annual Tech QC records (one year) 11 12 3

Technologist Quality Control Stereotactic Breast Biopsy Daily Localization Accuracy Test Phantom Imaging (weekly) Printer QC (monthly) Visual Checklist (monthly) Compression (semi-annually) Repeat Analysis (quarterly) Zero Alignment Test (per manufacturer) Dark Room Testing (if using film screen) Annual testing required by physicist ACR QC Manual available Ref: Stereotactic Breast Biopsy Quality Control Manual 1999 American College of Radiology 13 14 Stereotactic Breast Biopsy Annual Test Stereotactic Breast Biopsy Annual Test Unit Assembly Evaluation Collimation Assessment Focal Spot Performance and System Limiting Spatial Resolution kvp Accuracy Beam Quality Assessment (Half Value Layer) Automatic Exposure Control(AEC) or Manual Exposure Assessment Uniformity of Screen Speed (Screen Film Systems) Digital Receptor Uniformity (For Digital Image Receptors) Breast Entrance Exposure, Average Glandular Dose, and Exposure Reproducibility 15 16 4

Stereotactic Breast Biopsy Annual Test Unit Assembly Evaluation Image Quality Evaluation Artifact Evaluation Localization Accuracy Test Mechanically Stable Moving parts Locks/Detents Image receptor no vibes Compressed breast thickness indicator No rough edges Technique charts 512/1024 modes Radiation shielding Needle guides support needle 17 18 Collimation Collimation CR Image If any edge of radiation field deviates more than 5 mm from the edge of the image receptor, or if any edge of the compression paddle projects into the X-ray field by more than 5 mm, then seek service adjustment. 19 20 5

What is the maximum allowable alignment deviation of the radiation field edge to the image receptor for a stereotactic breast biopsy system? 1. 1 mm 2. 2 mm 3. 3 mm 4. 4 mm 5. 5 mm 5. 5 mm Answer Ref: Stereotactic Breast Biopsy Quality Control Manual 1999, Medical Physicist Section, Collimation Assessment, American College of Radiology 10 21 22 Focal Spot Performance and System Limiting Resolution kvp Action Limit: Note any significant degradation from previous measurement and seek service. Action Limit: If the mean kvp differs from the nominal by more than +/- 5% of the nominal kvp, or if the coefficient of variation exceeds 0.02, then seek service correction 23 24 6

Beam Quality Half Value Layer Automatic Exposure Control (AEC) HVL kvp/100 25 26 Technique Chart AEC Performance Breast Thickness Exposure Mode kvp Setting Density Control Setting Phototimed (Yes or No) < 3 cm 512 26 N/A Yes 3 to 5 cm 512 28-30 N/A Yes 5 to 7 cm 512 30-32 N/A Yes > 7 cm 512 34 N/A Yes Breast Thickness Exposure Mode kvp Setting Density Control Setting Phototimed (Yes or No) < 3 cm 1024 28 N/A Yes 3 to 5 cm 1024 30-32 N/A Yes 5 to 7 cm 1024 32-34 N/A Yes Select kvp Use AEC and make exposure Measure mean pixel value in center of field Meet manufacturers specificatiions > 7 cm 1024 34 N/A No 400 mas 27 28 7

AEC Digital Field Uniformity Both 512 and 1024 modes Ideally, clinical techniques (whether AEC or manual) should keep exposure times underr 2 seconds while meeting manufacturers signal requirements Ref: Stereotactic Breast Biopsy Quality Control Manual 1999 29 Action Limit: If SNR(I) / SNR(Center) is > 1.15 or < 0.85, seek service correction. 30 Digital Field Uniformity Breast Entrance Exposure Average Glandular Dose, and Exposure Reproducibility May require manufacturers service manual for procedure. Use AEC to expose Phantom Find closest manual technique Replace phantom with ion chamber Make 4 exposures 31 32 8

Dose Dose We check both 512 and 1024 modes Made change to technique chart to get 1024 mode to be less than 300 mrad The average glandular dose to an average (4.2 cm compressed) breast should not exceed 3 mgy (300 mrad) per view for filmscreen or digital image receptors 33 34 Breast Thickness Technique Chart Exposure Mode kvp Setting Density Control Setting Phototimed (Yes or No) < 3 cm 512 26 N/A Yes 3 to 5 cm 512 28-30 N/A Yes 5 to 7 cm 512 30-32 N/A Yes > 7 cm 512 34 N/A Yes Breast Thickness Exposure Mode kvp Setting Density Control Setting Phototimed (Yes or No) < 3 cm 1024 28 N/A Yes 3 to 5 cm 1024 30-32 N/A Yes 5 to 7 cm 1024 32-34 N/A Yes > 7 cm 1024 34 N/A No 400 mas 35 What is the maximum allowable dose per view to a 4.2 cm compressed breast as recommended by the ACR? 1. 1.5 mgy 2. 2.0 mgy 3. 2.5 mgy 4. 3.0 mgy 5. 3.5 mgy 10 36 9

Answer Image Quality Evaluation 4. 3.0 mgy Ref: Stereotactic Breast Biopsy Quality Control Manual, Medical Physicist Section Breast Entrance Exposure, Average Glandular Dose, and Exposure Reproducibility 37 38 Required Minimum Scores-Film Screen Required Minimum Scores - Digital Receptor Mammography Accreditation Phantom Mini-phantom Mammography Accreditation Phantom Mini-phantom 4.0 Fibers 3.0 Specs 3.0 Masses 2.0 Fibers 2.0 Specs 2.0 Masses 5.0 Fibers 4.0 Specs 3.5 Masses 3.0 Fibers 3.0 Specs 2.5 Masses Total: 10.0 Total: 6.0 Total: 12.5 Total: 8.5 39 40 10

What are the minimum scores for a digital receptor when using the miniphantom? 1. 1.0 Fibers, 1.0 Spec groups, 1.0 Masses 2. 2.0 Fibers, 2.0 Spec groups, 2.5 Masses 3. 3.0 Fibers, 3.0 Spec groups, 2.5 Masses 4. 3.5 Fibers, 3.5 Spec groups, 3.0 Masses 5. 4.0 Fibers, 4.0 Spec groups, 4.0 Masses Answer 3. 3.0 Fibers, 3.0 Spec groups, 2.5 Masses Ref: Stereotactic Breast Biopsy Quality Control Manual, Medical Physicist Section Image Quality Evaluation 10 41 42 Artifact Evaluation Localization Accuracy Test Note any artifacts or non-uniformities in the field. Both 512 and 1024 modes 43 44 11

Localization Localization 45 46 Daily Localization Accuracy Test 47 48 12

Breast Ultrasound Accreditation Program Requirements - QC 49 50 Physicist Report or Service Engineer Report As part of accreditation, facilities must submit a copy of the service engineer s most recent preventative maintenance report or the medical physicist s most recent equipment survey. Although the ACR will not initially use this information to determine whether a facility passes or fails accreditation, it may be used in the future to set criteria What is the recommended frequency for equipment surveys of ultrasound equipment for the ACR s breast ultrasound accreditation program? 1. Quarterly 2. Semiannually 3. Annually 4. Every other year 5. None 51 10 52 13

Answer Electrical Mechanical Condition 2. Semi-annually Ref: Stereotactic Breast Biopsy Accreditation Program Requirements http://www.acr.org/accreditation/breast.aspx Power cord Wheel Locks, Brakes Housing Scan Head Cable, Plugs Scan Head Housing, Window Monitor Air Filters VCR Printer Function 53 54 Maximum Depth of Visualization Vertical Distance Accuracy 55 56 14

Horizontal Distance Accuracy Uniformity 57 58 Anechoic Void Perception Ring Down Dead Zone 59 60 15

Lateral Resolution Axial Resolution 61 62 16