Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study.

Similar documents
The Tip-Edge appliance and

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System

Experience with Contemporary Tip-Edge plus Technique A Case Report.

Simply Great Wire! Great prices.

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System.

The load/deflection characteristics of thermally activated orthodontic archwires

Aesthetic Brackets and Accessories

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires

wiirre e a a n n d d w wiirre e ffo orrms ms

THE USE OF VACCUM FORM RETAINERS FOR RELAPSE CORRECTION

Space Closure Biomechanics Applied Using The MBT System Technique

Correction of Crowding using Conservative Treatment Approach

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

The management of impacted

BRACKET CHOICES SYSTEM CHOICES. Empower 2 reconvertible molar tubes provide versatility without compromise.

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

S.H. Age: 15 Years 3 Months Diagnosis: Class I Nonextraction Severe crowding, very flat profile. Background:

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports

How to place a lower bonded retainer

A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial

Bracket Systems. A good bracket is the foundation of a good treatment plan... Go ahead, choose the best. Metal Bracket.

Little Effort, 28 MAY 2016 // orthotown.com. clinical orthodontics // feature. How do you handle extraction spaces? This

A randomized clinical trial to compare three methods of orthodontic space closure

Orthodontic treatment of midline diastema related to abnormal frenum attachment - A case series.

ABSTRACT INTRODUCTION /jp-journals

Low-Force Mechanics Nonextraction. Estimated treatment time months (Actual 15 mos 1 week). Low-force mechanics.

A New Low-Friction Ligation System

Dual Force Cuspid Retractor

Segmental Orthodontics for the Correction of Cross Bites

ORTHOdontics SLIDING MECHANICS

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS. Part One

Coated, uncoated stainless steel ligatures versus Self ligation- In the perspective of friction

American Orthodontics (800) NiTi, superelastic NiTi, thermal NiTi x.022,.017 x.025,.018 x.025,.019 x.025

TOL

A Novel Method of Altering the Buccal Segment Relationship

essentialstm cutting your consumable costs brackets tubes wires springs instruments T:

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D.

Lower Anterior Crowding Correction by a Convenient Lingual Methodjerd_

Photo-elastic stress analysis of initial alignment archwires

The Reinforced Removable Retainer

An In-Vivo Comparison Of The Efficacy Between Direct And Indirect Bonding Methods

ORTHODONTIC INTERVENTION IN MIXED DENTITION: A BOON FOR PEDIATRIC PATIENTS

TransForce 2. Arch Developer Appliances Clinical Cases. New Horizons In Orthodontics

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases

GAC Archwire Collection

MBT System as the 3rd Generation Programmed and Preadjusted Appliance System (PPAS) by Masatada Koga, D.D.S., Ph.D

Archwires & Accessories

With judicious treatment planning, the clinical

MemRx Orthodontic Appliances

A New Fixed Interarch Device for Class II Correction

Gentle-Jumper- Non-compliance Class II corrector

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment

Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy

Ectopic upper canine associated to ectopic lower second bicuspid. Case report

A Modified Three-piece Base Arch for en masse Retraction and Intrusion in a Class II Division 1 Subdivision Case

Crowding and protrusion treated by unusual extractions

The effectiveness of laceback ligatures: A randomized controlled clinical trial

ARCHWIRE. An extensive selection of high quality wire types and arch forms WIRE PRODUCTS. Wires. TruFlex Nickel Titanium Archwire. TruFlex.

Class I. Clear Fixed Appliance vs. Aligner Treatment for Arch Development. Clinician: Dr. Stuart Frost, Phoenix, AZ Patient: A.M.

Quality. Elegance. Innovation.

Non Extraction philosophy: Distalization using Jone s Jig appliance- a case report

Developing lingual orthodontics

Outline the significance of the pre-adjusted Edgewise appliance system and useful bracket variations in orthodontics

An Effectiv Rapid Molar Derotation: Keles K

A Collection of High Quality Orthodontic Instruments

The Science Behind The System Clinical Abstracts, Volume 2

The Ultimate in Crystal Clear Aesthetics

Clarity. Form meets function: Discover the science behind a versatile self-ligating bracket system. Aesthetic Orthodontic Solutions

6. Timing for orthodontic force

Premium Heat Activated Arch Wire

Canine Extrusion Technique with SmartClip Self-Ligating Brackets

THE MBT VERSATILE+ APPLIANCE SYSTEM

Perception of pain and discomfort from three different types of orthodontic separators

Treatment of an open bite case with 3M Clarity ADVANCED Ceramic Brackets and miniscrews.

A Case Report on Clinical Management of Impacted Maxillary Cuspid and Bicuspid through Surgical Exposure and Orthodontic Alignment

Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires

MECHANICAL PROPERTIES OF ORTHODONTIC NICKEL-TITANIUM OPEN COIL SPRINGS

THE RELIABLE AESTHETIC CHOICE

IJPCDR ORIGINAL RESEARCH ABSTRACT INTRODUCTION

Measurements of the torque moment in various archwire bracket ligation combinations

Study Model-based Evaluation of Built-in Tip, Torque, and In out Characteristics of a Third-generation Preadjusted Edgewise Appliance

Establishment of norms for crown angulation and inclination among Maratha population: Cross-Sectional Study

Unilateral Horizontally Impacted Maxillary Canine and First Premolar Treated with a Double Archwire Technique

Wire is the key player in the movement of teeth, so choosing the right wire is critical for successful treatment. ODP offers a full range of wire

The resolution of mandibular incisor

Characterizing constraining forces in the alignment phase of orthodontic treatment

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

ABSTRACT INTRODUCTION /jp-journals

AL-AZHAR. Dental Journal. Print ISSN Online ISSN ADJ-for Girls, Vol. 5, No. 1, January (2018) PP. 9:14

2007 JCO, Inc. May not be distributed without permission.

Class II. Bilateral Cleft Lip and Palate. Clinician: Dr. Mike Mayhew, Boone, NC Patient: R.S. Cleft Lip and Palate.

JCO-Online Copyright 2010

3D CONTROL HAS ARRIVED

Comparison of Niti and TiNbTaZr Archwires During Initial Orthodontic Alignment THESIS

Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction Treatment?

Transcription:

IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 9, Issue 3 (Jul.- Aug. 2013), PP 47-51 Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study. DR. R. Ramya Vimalathithan 1, M.D.S., Dr.N.Kurunji kumaran 2, M.D.S, Ph.D., Dr. K. Rajasigamani 3, M.D.S., Dr.R.S.Chenguttuvan 4, M.D.S 1,4 (Department Of Orthodontics and Dentofacial Orthopedics, Madha Dental College and Hospital, Chennai, Tamilnadu, India.) 2,3 (Department Of Orthodontics and Dentofacial Orthopedics Rajah Muthiah Dental College and Hospital, Annamalai Nagar, Chidambaram, Tamilnadu, India.) Abstract: Introduction: One of the most perplexing phenomenons in orthodontics is the crowding of anterior teeth, which brings the patient to the orthodontist seeking remedy because of its aesthetic and functional consequences. The present study was aimed to clinically evaluate and compare the efficiency of NiTi and multistranded stainless steel wire during initial levelling and aligning of crowded lower anteriors. Material and methods: 30 subjects aged between 14-20 were chosen for the study and divided in to two groups. All the subjects were fully explained about nature, purpose and treatment. Both groups were bonded with 0.022 MBT prescription brackets. After bonding, for Group A patients 0.016 NiTi arch wire was placed and secured with elastomeric modules, similarly for Group B patients 0.0155 multistranded (SS) wire was placed and secured.time period needed for decrowding of each group was calculated. Result: Average number of days taken by nickel titanium wire in de-crowding mandibular anteriors is 89.67 days while multistranded SS wire took 113.2 days to de-crowd. Even though multistranded wire has low stiffness, because of its shape memory and super elasticity, nickel titanium wire is clinically efficient in decrowding severely crowded lower anteriors. To conclude, a marginal advantage of NiTi wire exists in accordance to the time period taken to decrowd mandibular anteriors. Keywords: Aligning, Decrowding, Multistranded wire, NiTi wire, Shape memory. I. Introduction One of the most perplexing phenomenons in orthodontics is anterior crowding. Vander Linden [1] classified crowding on the basis of its cause as primary, secondary, and tertiary. He defined primary crowding as an inherent discrepancy between tooth size and the available arch length, mainly of genetic origin. Secondary crowding was caused by environmental factors influencing the dentition, such as caries and extractions. Tertiary crowding or late crowding occurs in the post-adolescent period. Newer wires and innovations in the bracket systems have simplified and reduced the time span of the aligning stage. One such innovation is Nickel titanium (NiTi) wires with the advantages of superelasticity, torsional strength, stress constancy, physiological compatibility, shape memory, dynamic interference, and wear resistance hysteresis. Earlier multistrand wire prevailed over multilooped arch wires due to their mechanical advantage, preformed availability and low load deflection rate. Even though NiTi performance is superior in in-vitro [2,3,4], the present study was aimed to clinically evaluate and compare the efficiency of NiTi and multistranded stainless steel wire during initial leveling and aligning of crowded lower anteriors. II. Materials and Method A total of 102 patients screened out of which, 30 subjects (aged 14-20) who fulfilled the following inclusion/exclusion criteria, were chosen for the study and divided in to two groups(group A and Group B) among which 17 were male and 13 were female. 2.1 Inclusion criteria: Subjects with following criteria were included in the study, Crowding in lower arch with irregularity index in the range of 7-9 (severe crowding). Therapeutic extraction of mandibular first premolars. All the permanent teeth erupted except third molar before experiment. 47 Page

2.2 Exclusion criteria Subjects with following criteria were not included in the study, Congenitally missing permanent teeth, Systemic disease condition, History of previous orthodontic treatment or trauma to orofacial region. All the subjects were informed about the nature, purpose and treatment procedure. The study was duly reviewed and accepted by the Institutional human ethical committee. (IHEC, Annamalai University, India) The little s irregularity index [5] was used to assess the crowding and the measurements were made on the initial cast using fine tip digital calliper and all values recorded. All the clinical procedures were carried out by single operator (Dr.Ramya). The bonding procedure was standardised to all the subjects according to the manufacturer s specification. The bonding of 0.022 MBT brackets (Mini Master brackets, American orthodontics.) was done using light cure adhesive paste and primer (Transbond 3M Unitek). Passive lacebacks [6] were placed and were not tightened in subsequent visits. Group A subjects received 0.016 NiTi arch wire, where as Group B subjects received 0.0155 multistranded wire (SS). The wires were secured with elastomeric modules and cinched. Subjects reported with loose bands, broken wires or lacebacks, dislodged brackets, missing or lost modules, poor oral hygiene maintenance leading to gingival hyperplasia will be excluded from the study and considered to be drop outs. Patients were reviewed every month and modules changed in each appointment. Completion of decrowding was judged by visual inspection of proximal contacts and by little s irregularity index. Intra oral photographs and casts were made (figure 1, 1a, 2, 2a, 3, 3a and 4, 4a). The date of bonding and date of decrowding were recorded as D1 and D2 respectively. The time period taken for decrowding of mandibular anteriors for each groups was calculated as D2-D1. III. Result The arithmetic mean and standard deviation were calculated. Paired student T test with 95% confidence level was used to compare both groups. Statistical significance level was established at P < 0.05. Construction of 95 percent confidence interval (PCI) and application of T-test to test the equality of mean days between multistranded wire and Nickel Titanium wire in de-crowding mandibular anteriors (Table 1&Graph 1). Average number of days taken by nickel titanium wire in de-crowding mandibular anteriors is 89.67 days while multistranded SS wire took 113.2 days to de-crowd. As the observed P value 0.0004 is less than 0.05 (5%), we rejected the equality of mean days between multistranded wire and Nickel Titanium wire and the difference in such means is significant. Further the average number of days of the Nickel Titanium wire group is smaller than multistranded wire group, it was concluded that Nickel Titanium wire performed better than multistranded wire. IV. FIGURES AND TABLES Figure 1: Day one of bonding (D1) and after placement of NiTi wire (Group A) Figure 1a: After decrowding (D2) using NiTi wire (Group A) 48 Page

Figure 2: Day one of bonding (D1) and after placement of NiTi wire (Group A) Figure 2a: After Decrowding (D2) using NiTi wire (Group A) Figure 3: Day one of bonding (D1) and after placement of multistranded stainless steel wire (Group B) Figure 3a: After decrowding (D2) using multistranded stainless steel wire (Group B) Figure 4: Day one of bonding (D1) and after placement of multistranded stainless steel wire (Group B) 49 Page

Figure 4a: After decrowding (D2) using multi strandedstainless steel wire (Group B) Table 1: Statistical comparison of mean number of days taken by multistranded stainless steel wire and nickel titanium wire to decrowd the mandibular anteriors. N Mean SD DF T P TYPE OF WIRE observed value Multistranded SS wire 15 113.2 3 10 6.82 0.0004 Nickel Titanium wire 15 89.67 8 N-Sample size, SD-Standard deviation, DF-Degree of freedom, P Value-5% level of significance. Graph 1: Comparison of number of days between NiTi and multistranded stainless steel wire in decrowding lower anteriors V. DISCUSSION Although it is generally accepted that tooth movement should be undertaken with light forces, there is only circumstantial evidence to guide the clinician as to the appropriate level of force that should be applied, particularly during the initial alignment of irregular teeth. Hyalinization of the periodontal ligament and consequent delays in tooth movement are liable to occur when any but the lightest forces are used for this type of movement as shown by Reitan [7]. Waters et al [4] have shown that conventional arch wires can generate very large forces, even when deflected by only very small amounts. The introduction of new metallic alloys paved way for rethinking the use of multi-looped arch wires for alignment. With newer alloys, the chair side time and duration of the treatment period were considerably reduced with less discomfort to the patient. One such alloy is Nickel titanium wires which have won a worldwide acceptance because of its high spring back and low stiffness. With the advent of the heat activated NiTi the range further increased. One of the favourable properties of small diameter wire is its increased springiness; however its strength is questionable. When more than one small diameter wires are coiled together like multistranded wire, the property of springiness is almost maintained along with an increase in strength. Hence a 0.0175 multistranded wires will have much more range and springiness than a 0.018 steel wire, and a much higher strength than the individual wires that are coiled. Finally the properties of multistranded wires depend on the individual wires that are coiled, and on how tightly they are coiled together. Kusy and Stevens [8] studied the properties of triple stranded 0.0175 (3x0.008 ) SS wire and found that the stiffness was comparable to that of 0.016 NiTi. In contrast, in our study we encountered deformation of multistranded wire. Ingram et al [3] showed that for multistranded wires, the range was independent of wire size 50 Page

and nearly consistent for different configurations of wires. This applies to round as well as rectangular multistranded wires. Although multistranded wire might be an option, according to Taneja et al [9] they do not display the consistently low and moderately decreasing forces at different degree of deflection as NiTi wires do. Therefore, the clinician must have knowledge of the behaviour of multistranded wire when using them as NiTi substitutes. The statistically significant difference in the performance of individual wires in various mechanical test stimulations, does not guarantee such difference will exist in clinical performance. In a crowded dentition, the high force may be dissipated through inter dental contacts and in overcoming friction among the brackets, wire, and ligatures. Evans et al [10] compared the alignment efficiency of multistranded stainless steel wire, superelastic NiTi and thermoactivated NiTi over a longer period in a controlled randomized trial and found no significant difference in aligning capability of these three wires. However in the present study NiTi wire decrowded the lower anteriors 21 days ahead of multistranded SS wire, this could be due to the increased incidence of wire deformation in multistranded stainless steel wires than super elastic NiTi wires. From the clinical point of view this marginal difference will not promise a reduction in treatment duration during aligning stage. Since our study focus only on the initial aligning stage, further studies are required to judge the efficiency of variable dimensions of NiTi wire at different treatment stages. The amount of crowding should be a major consideration in selection of the wire, hence the present study recommends the use of NiTi wires for severely crowded lower anteriors where as multistranded SS wire might perform competitively in mild to moderate crowding. VI. Conclusion The following conclusion were drawn, 1. The average mean number of days taken by NiTi wire in decrowding mandibular anteriors was 89 days. 2. The average means number of days taken by multistranded stainless steel wire in decrowding mandibular anteriors was113days. 3. NiTi wires are efficient in decrowding the severely crowded lower anteriors than multistranded SS wires. 4. Incidence of wire deformation is increased in multistranded stainless steel wires than super elastic NiTi wires. To conclude, with in the limitations of the present study, even though NiTi wires are efficient than multistranded SS wire, this can be considered as marginal advantage in accordance to the time period taken to decrowd mandibular anteriors. REFERENCES [1]. Van der Linden FP. Theoretical and practical aspects of crowding in the human dentition. J Am Dent Assoc. Jul, 89(1), 1974, 139-53. [2]. Rucker BK, Kusy RP. Elastic flexural properties of multistranded stainless steel versus conventional nickel titanium archwires. Angle Orthod. Aug, 72(4), 2002, 302-9. [3]. Ingram SB Jr, Gipe DP, Smith RJ. Comparative range of orthodontic wires. Am J Orthod Dentofacial Orthop. Oct, 90(4), 1986, 296-307. [4]. Waters NE, Stephens CD, Houston WJB. Physical characteristics of orthodontic wires and arch wires. Br. J. Orthod. 2, 1975, 73 83. [5]. Little RM. The irregularity index: a quantitative score of mandibular anterior alignment. Am J Orthod. Nov, 68(5), 1975, 554-63. [6]. Richard P. McLaughlin, John C. Bennett, Hugo J. Trevisi. Systemized Orthodontic Treatment Mechanics( Mosby, 2001 p.100.) [7]. Reitan K. Some factors determining the evaluation of forces in orthodontics. Am. J.Orthod. 43: 1957, 33-45. [8]. Kusy RP, Stevens LE. Triple-stranded stainless steel wires--evaluation of mechanical properties and comparison with titanium alloy alternatives. Angle Orthod. Jan, 57(1), 1987, 18-32. [9]. Taneja P, Duncanson MG Jr, Khajotia SS, Nanda RS. Deactivation force-deflection behavior of multistranded stainless steel wires. Am J Orthod Dentofacial Orthop. Jul,124(1), 2003, 61-8. [10]. Evans TJ, Jones ML, Newcombe RG.Clinical comparision and performance perspective of three aligning arch wires. Am J Orthod Dentofacial Orthop. Jul, 114(1), 1998,32-9. 51 Page