DetectX Hemoglobin High Sensitivity Colorimetric Detection Kit

Similar documents
DetectX Hemoglobin Colorimetric Detection Kit

DetectX HEMOGLOBIN Colorimetric Detection Kit

Human Hemoglobin Colorimetric Detection Kit

DetectX. Urinary Creatinine Detection Kit. Catalog Number K002-H1. Sample Types Validated: Human, Monkey, Dog, Rat and Mouse Urine

DetectX GLUCOSE Fluorescent Detection Kit

DetectX THYROXINE (T 4 ) Enzyme Immunoassay Kit

DetectX TRIIODOTHYRONINE (T 3 ) Enzyme Immunoassay Kit

DetectX ESTRONE Enzyme Immunoassay Kit

DetectX NITRIC OXIDE Colorimetric Detection Kit

DetectX GALACTOSE Colorimetric Detection Kit

Estrone Enzyme Immunoassay Kit

DetectX ALDOSTERONE Enzyme Immunoassay Kit

DetectX 17ß-ESTRADIOL Enzyme Immunoassay Kit

DetectX GLUTATHIONE Colorimetric Detection Kit

DetectX CORTISONE Enzyme Immunoassay Kit

Estrone. Enzyme Immunoassay Kit. 1 Plate Kit Catalog Number 1C Plate Kit Catalog Number 1C7871. Species Independent. Sample Types Validated:

DetectX PROSTAGLANDIN E 2 Enzyme Immunoassay Kit

DetectX LEVONORGESTREL (LNG) Enzyme Immunoassay Kit

Estrone EIA kit. For the quantitative determination of estrone in dried fecal extracts, urine and tissue culture media. Cat. No.

DetectX ALDOSTERONE Chemiluminescent Immunoassay Kit

Aldosterone Enzyme Immunoassay Kit

Cortisol Enzyme Immunoassay Kit

Urea Nitrogen (BUN) detection Kit

DetectX SERUM 17ß-ESTRADIOL Enzyme Immunoassay Kit

Blood Urea Nitrogen Detection Kit

DetectX OXYTOCIN Enzyme Immunoassay Kit

Human Creatinine Urinary Detection Kit

DetectX. Prostaglandin E 2. Enzyme Immunoassay Kit. 1 Plate Kit Catalog Number K018-H1 5 Plate Kit Catalog Number K018-H5. Sample Types Validated:

DetectX. Prostaglandin E 2. Enzyme Immunoassay Kit. 1 Plate Kit Catalog Number K051-H1 5 Plate Kit Catalog Number K051-H5. Sample Types Validated:

DetectX PKA (PROTEIN KINASE A) Activity Kit

NIST-Calibrated Kit. Cortisol Enzyme Immunoassay Kit. Species Independent. Sample Types Tested:

DetectX CORTISONE Chemiluminescent Immunoassay Kit

TiterZyme EIA mouse IL-5 Enzyme Immunometric Assay Kit

DetectX OXYTOCIN Chemiluminescent Immunoassay Kit

Galactose Colorimetric Detection Kit

DetectX. Prostaglandin E 2. Chemiluminescent Enzyme Immunoassay Kit. 1 Plate Kit Catalog Number K018-C1 5 Plate Kit Catalog Number K018-C5

HbA1c (Human) ELISA Kit

Human Cortisol Enzyme Immunoassay Kit

Morinaga Mouse C-peptide ELISA Kit

Mouse Estradiol EIA Kit

Enzyme Immunoassay for

Human HIV (1+2) antigen&antibody ELISA Kit

RayBio Human Granzyme B ELISA Kit

Rat Hemoglobin A1c (HbA1c) Kit Instructions

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Estriol ELISA kit. Catalog Number KA assays Version: 05. Intended for research use only.

VOLUME & NORMALIZATION ASSAY KITS

RayBio Human ENA-78 ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit

ab Creatinine Assay Kit (Colorimetric)

Human Hydrogen Peroxide Fluorescent Detection Kit

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Mouse C-Peptide ELISA Kit

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

AlphaScreen Nickel Chelate Donor Beads at 5 mg/ml in 25 mm Hepes, ph 7.4, 100 mm

LDL (Human) ELISA Kit

Hemoglobin Colorimetric Assay Kit

Prothrombin (Human) ELISA Kit

TNF-alpha ELISA. For Research Use Only. Not For Use In Diagnostic Procedures.

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

Human Thyroglobulin EIA

Tetracycline Plate Kit (for Honey) PN 52254B

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Nori Rabbit IL-2 ELISA Kit DataSheet

Rat cholesterol ELISA Kit

Abraxis Progesterone (bovine) ELISA Kit

Porcine/Canine Insulin ELISA

Fish follicle-stimulating hormone, FSH ELISA Kit

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

RayBio Human Thyroglobulin ELISA Kit

Insulin (Porcine/Canine) ELISA

Cortisol EIA Kit. StressXpress. Catalog# SKT-201 (96-Well Kit) Discovery through partnership Excellence through quality

Bovine Insulin ELISA

Mouse C-peptide ELISA

Procine sphingomyelin ELISA Kit

Prostaglandin E2 EIA (Multi-format) Kit

Human Immunodeficiency Virus type-1 p24 protein (HIV p24) Kit

Estriol ELISA kit. Catalog No. ADI Well Kit Table of Contents

Mouse C-peptide ELISA

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Mouse Leptin ELISA Kit Instructions

Rat Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA kit

Human Myeloperoxidase EIA Kit Product Number: MP14 Store at 4 C FOR RESEARCH USE ONLY Document Control Number: MP14.

Cortisol (Sheep) ELISA Kit

Mouse Ultrasensitive Insulin ELISA

Total Bilirubin Assay Kit Manual Catalog #:

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

BIOO RESEARCH PRODUCTS. Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

Influenza A IgG ELISA

Hepatitis B Virus Surface antigen (HBsAg) AlphaLISA Detection Kit

Human Myeloperoxidase ELISA KIT

Prostaglandin E 2. Chemiluminescent Enzyme Immunoassay Kit. 1 Plate Kit Catalog Number FP-1C0620. Species independent. Sample Types Validated:

TABLE OF CONTENTS GENERAL INFORMATION... 1

TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C

Human LDL ELISA Kit. Innovative Research, Inc.

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet

Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

Transcription:

DetectX Hemoglobin High Sensitivity Colorimetric Detection Kit 2 Plate Kit Catalog Number K013-HX1 10 Plate Kit Catalog Number K013-HX5 Species Independent Sample Types Validated: Serum and Plasma Please read this insert completely prior to using the product. For research use only. Not for use in diagnostic procedures. www.arborassays.com

TABLE OF CONTENTS Background 3 Assay Principle 4 Related products 4 Supplied Components 5 Storage Instructions 5 Other Materials Required 6 Precautions 6 Sample Types 7 Sample Preparation 7 Reagent Preparation 8 Assay Protocol 9 Calculation of Results 10 Typical Data 10-11 Validation Data Sensitivity, Linearity, etc. 11-13 Sample Values, Interferents and Kit Correlation 14 Warranty & Contact Information 15 Plate Layout Sheet 16 2 EXPECT ASSAY ARTISTRY

BACKGROUND Hemoglobin (Hgb) is an erythrocyte protein complex comprised of two sets of identical pairs of subunits, each of which bind an iron-prophyrin group commonly called heme. Generally containing two alpha or alpha-like globulin chains, the remaining subunits may be beta, gamma, delta or epsilon, or in the case of infants, fetal hemoglobin that is replaced during the first year of life. Heme binds and releases oxygen or carbon dioxide in response to slight changes in local gas tension 1. Free oxygen or carbon dioxide bound by one heme group facilitates subsequent binding by the other heme groups in a given hemoglobin molecule 2. Subtle changes in ph also regulate hemoglobin affinity for free gases, resulting in a high level of hemostatic control. Hemoglobin values are associated with a variety of conditions ranging from anemias (low Hgb), erythrocytosis (high Hgb), thalassemias (aberrant chain synthesis), and sickling disorders (abnormal complex shape) 1. The universal reference procedure for hemoglobin determination in blood has been the cyanmethemoblobin method as determined by the Clinical and Laboratory Standards Institute TM and the International Council for Standardization in Haematology 3-5. In this method, ferricyanide and potassium cyanide convert hemoglobin to a more stable cyanmethemoglobin form that is measured photometrically. While this method is straightforward and uses a single reaction solution, not all forms of hemoglobin are converted to cyanmethemoglobin at the same rate or even to completion. In addition to the safety issues surrounding cyanide, the reagent itself is not stable, so extra care needs to be taken to ensure the quality of any measurement. 1. Tietz, NW, Textbook of Clinical Chemistry, WB Saunders Company, Philadelphia. 2. Manning, JM et al., Normal and abnormal protein subunit interactions, 1998,J Biol Chem. 273(13):19359-62. 3. Drabkin, DL and JH Austin, Spectrophotometric Studies: II. Preparations from washed blood cells; nitric oxide hemoglobin and sulfhemoglobin, 1935, J Biol Chem, 112(1):51-65. 4. Bull, BS, et al., Reference and selected procedures for the quantitative determination of hemoglobin in blood; approved standard third edition, NCCLS Vol. 20 No. 28. NCCLS document H15-A3. 5. Rowan, RM, Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobincyanide standard (4th edition), 1996, J Clin Pathol, 49:271-74. www.arborassays.com 3

ASSAY PRINCIPLE The DetectX High Sensitivity Hemoglobin Detection Kit is designed to quantitatively measure all forms of hemoglobin present in plasma and serum. Please read the complete kit insert before performing this assay. A human hemoglobin standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. Standards or diluted samples are pipetted into a clear microtiter plate and the ready-to-use Hemoglobin Detection Reagent is added to each well. The plate is incubated for 30 minutes at room temperature. Stop solution is added at the end of 30 minutes and the plate is read at 450 nm. The concentration of the hemoglobin in the sample is calculated, after making suitable correction for dilution, using software available with most plate readers. RELATED PRODUCTS Kits Hemoglobin Colorimetric Detection Kits Serum Creatinine Detection Enzyme Kit Retinol Binding Protein Multi-Format EIA Kits Glutathione Fluorescent Detection Kits Glutathione Colorimetric Detection Kit Glutathione S-Transferase Activity Kit Glutathione Reductase Activity Kit Cystatin C Enzyme Immunoassay Kit Cortisol Enzyme Immunoassay Kits Corticosterone Enzyme Immunoassay Kits Acetylcholinesterase Fluorescent Activity Kit Butyrylcholinesterase Fluorescent Activity Kit Prostaglandin E 2 Multi-Format EIA Kits Catalog No. K013-H1/H2 KB02-H1 K062-H1/H5 K006-F1/F5 K006-H1 K008-F1 K009-F1 K012-H1 K003-H1/H5 & K003-H1W/H5W K014-H1/H5 K015-F1 K016-F1 K051-H1/H5 4 EXPECT ASSAY ARTISTRY

SUPPLIED COMPONENTS Clear 96 Well Plates Bag containing 2 by 9 well plates or 2 bags, each containing 5 by 9 well plates. Kit K013-HX1 or -HX5 2 or 2 by 5 each Catalog Number X003-2EA or -5EA Hemoglobin Standard A stock solution of native human hemoglobin at 200 µg/ml. Kit K013-HX1 or -HX5 90 μl or 450 µl Catalog Number C246-90UL or -450UL Assay Buffer Concentrate A 5X concentrate that must be diluted with deionized or distilled water. Kit K013-HX1 or -H5 28 ml or 55 ml Catalog Number X067-28ML or -55ML DetectX Hemoglobin Detection Reagent Kit K013-HX1 or -HX5 11 ml or 55 ml Catalog Number C248-11ML or -55ML Stop Solution A 1M solution of hydrochloric acid. CAUSTIC. Kit K013-HX1 or -HX5 11 ml or 55 ml Catalog Number X020-5ML or -25ML STORAGE INSTRUCTIONS All components of this kit should be stored at 4 C until the expiration date of the kit. www.arborassays.com 5

OTHER MATERIALS REQUIRED Distilled or deionized water. Repeater pipet with disposable tips capable of dispensing 25 and 50 µl. Colorimetric 96 well microplate reader capable of reading optical density at 450 nm. Software for converting raw relative optical density readings from the plate reader and carrying out four parameter logistic curve (4PLC) fitting. Contact your plate reader manufacturer for details. PRECAUTIONS As with all such products, this kit should only be used by qualified personnel who have had laboratory safety instruction. The complete insert should be read and understood before attempting to use the product. The Hemoglobin Standard is derived from human blood. It has been extensively tested for viral contamination, but all human blood products should be treated as potentially infectious and adequate precautions taken. Make sure all buffers used for samples are azide free. The Stop Solution is acid. The solution should not come in contact with skin or eyes. Take appropriate precautions when handling this reagent. 6 EXPECT ASSAY ARTISTRY

SAMPLE TYPES This assay has been validated for serum, as well as EDTA and heparin plasma samples from multiple species. Samples containing visible particulate should be centrifuged prior to using. SAMPLE PREPARATION Serum and Plasma Serum and plasma samples must be diluted 1:20 in the diluted Assay Buffer prior to running the kit. It is up to the end user to determine the appropriate dilution for their samples. Any samples with hemoglobin concentrations above the standard curve range should be diluted further to obtain readings within the standard curve. Hemoglobin is stable if stored at 4 C for 7 days. Samples may be frozen and stored at -20 C for long term storage. Use all samples within 2 hours of preparation or stored at -20 C until assaying. www.arborassays.com 7

REAGENT PREPARATION Allow the kit reagents to come to room temperature for 30 minutes. Ensure that all samples have reached room temperature and have been diluted as appropriate prior to running them in the kit. Assay Buffer Dilute Assay Buffer Concentrate 1:5 by adding one part of the concentrate to four parts of deionized water. Once diluted, this is stable at 4 C for 3 months. Standard Preparation Label glass test tubes as #1 through #7. Briefly vortex and spin the vial of standard in a microcentrifuge to ensure contents are at bottom of vial. Pipet 90 ul of prepared Assay Buffer into tube #1 and 50 µl of prepared Assay Buffer into tubes #2 to #7. Carefully add 10 µl of the Hemoglobin stock solution provided to tube #1 and vortex completely. Take 50 µl of the Hemoglobin solution in tube #1 and add it to tube #2 and vortex completely. Repeat the serial dilutions for tubes #3 through #7. The concentration of Hemoglobin in tubes #1 through #7 will be 20, 10, 5, 2.5, 1.25, 0.625 and 0.313 µg/ml. Use all Standards within 2 hours of preparation. Std 1 Std 2 Std 3 Std 4 Std 5 Std 6 Std 7 Assay Buffer Volume (µl) 90 50 50 50 50 50 50 Addition Stock Std 1 Std 2 Std 3 Std 4 Std 5 Std 6 Volume of Addition (µl) 10 50 50 50 50 50 50 Final Conc (µg/ml) 20 10 5 2.5 1.25 0.625 0.313 8 EXPECT ASSAY ARTISTRY

ASSAY PROTOCOL We recommend that all standards and samples be run in duplicate to allow the end user to accurately determine hemoglobin concentration. 1. Use the plate layout sheet on the back page of the insert to aid in proper sample and standard identification. 2. Pipet 10 µl of samples or standards into wells in the plate. Pipet 10 µl of Assay Buffer into the zero standard wells. 3. Add 50 µl of the DetectX Hemoglobin Detection Reagent to each well, using a repeater pipet. 4. Incubate at room temperature for 30 minutes. 5. Add 25 µl of the Stop Solution to each well, using a repeater pipet. 6. Read the optical density generated from each well in a plate reader capable of reading at 450 nm. 7. Use the plate reader s built-in 4PLC software capabilities to calculate Hemoglobin concentration for each sample. NOTE: If you are using only part of a strip well plate, at the end of the assay throw away the used wells and retain the plate frame for use with the remaining unused wells. www.arborassays.com 9

CALCULATION OF RESULTS Average the duplicate OD readings for each standard and sample. Create a standard curve by reducing the data using the 4PLC fitting routine on the plate reader, after subtracting the mean OD s for the Zero standard. The sample concentrations obtained should be multiplied by the dilution factor to obtain neat values. Or use the online tool from MyAssays to calculate the data: TYPICAL DATA Sample Mean OD Net OD Hemoglobin Conc. (µg/ml) Zero 0.049 0 0 Standard 1 1.675 1.626 20 Standard 2 0.856 0.807 10 Standard 3 0.437 0.388 5 Standard 4 0.220 0.171 2.5 Standard 5 0.124 0.075 1.25 Standard 6 0.084 0.035 0.625 Standard 7 0.067 0.018 0.313 Sample 1 0.847 0.798 9.87 Sample 2 0.350 0.301 4.04 Always run your own standard curve for calculation of results. Do not use this data. *The MyAssays logo is a registered trademark of MyAssays Ltd. 10 EXPECT ASSAY ARTISTRY

Typical Standard Curve 1.8 1.6 1.4 1.2 Net OD 1.0 0.8 0.6 0.4 0.2 0.0 0 2 4 6 8 10 12 14 16 18 20 Hemoglobin Concentration (µg/ml) Always run your own standard curves for calculation of results. Do not use this data. VALIDATION DATA Sensitivity and Limit of Detection Sensitivity was calculated by comparing the OD s for twenty (20) wells run for each of the zero and standard #7. The detection limit was determined at two (2) standard deviations from the zero along the standard curve. Sensitivity was determined as 0.053 µg/ml. The Limit of Detection for the assay was determined in a similar manner by comparing the OD s for twenty (20) replicates for each of the zero and a low concentration diluted human sample. Limit of Detection was determined as 0.082 µg/ml. www.arborassays.com 11

Linearity Linearity was determined by diluting two serum samples, one with a high diluted Hemoglobin level of 10.13 µl/ml and one with a low diluted level of 4.44 µg/ml, mixing them in the ratios given below and running in the assay. The measured concentrations were compared to the expected values based on the ratios used. High Sample Low Sample Observed Conc. (µg/ml) Expected Conc. (µg/ml) % Recovery 80% 20% 8.39 8.99 93.3 60% 40% 7.79 7.85 99.2 40% 60% 6.93 6.72 103.2 20% 80% 5.71 5.58 102.4 Mean Recovery 99.5% 9.00 y=0.7821x + 1.5076 R 2 = 0.97619 8.00 Observed Conc. (µg/ml) 7.00 6.00 5.00 5.00 6.00 7.00 8.00 9.00 Expected Conc. (µg/ml) 12 EXPECT ASSAY ARTISTRY

Intra Assay Precision Three serum samples were diluted with Assay Buffer and run in replicates of twenty (20) in an assay. The mean and precision of calculated Hemoglobin concentrations were: Sample Hemoglobin Conc. (µg/ml) %CV 1 11.05 2.8 2 7.45 2.9 3 4.26 2.0 Inter Assay Precision Three serum samples were diluted with Assay Buffer and run in duplicate in nineteen (19) assays run over multiple days by four operators. The mean and precision of calculated Hemoglobin concentrations were: Sample Hemoglobin Conc. (µg/ml) %CV 1 9.24 8.7 2 6.22 9.5 3 3.77 9.9 www.arborassays.com 13

SAMPLE VALUES Thirty-seven (37) human serum and plasma samples from normal, healthy individuals, one of whom was pregnant, were tested in the assay. Neat sample values ranged from 15.6 to 621.6 µg/ml. The normal reference range for serum Hemoglobin concentrations is 120 to 175 µg/ml and for plasma is 0 to 152 µg/ ml according to the Mayo Clinic 1. 1. Test ID: PLHBB Plasma Hemoglobin, Plasma. MayoMedicalLaboratories.com. https://www.mayomedicallaboratories.com/test-catalog/clinical+and+interpretive/9096 14 EXPECT ASSAY ARTISTRY

LIMITED WARRANTY Arbor Assays warrants that at the time of shipment this product is free from defects in materials and workmanship. This warranty is in lieu of any other warranty expressed or implied, including but not limited to, any implied warranty of merchantability or fitness for a particular purpose. We must be notified of any breach of this warranty within 48 hours of receipt of the product. No claim shall be honored if we are not notified within this time period, or if the product has been stored in any way other than outlined in this publication. The sole and exclusive remedy of the customer for any liability based upon this warranty is limited to the replacement of the product, or refund of the invoice price of the goods. CONTACT INFORMATION For details concerning this kit or to order any of our products please contact us: Arbor Assays 1514 Eisenhower Place Ann Arbor, Michigan 48108 USA Phone: 734-677-1774 Fax: 734-677-6860 Web: www.arborassays.com Email Addresses: Info@ArborAssays.com Orders@ArborAssays.com Technical@ArborAssays.com Contracts@ArborAssays.com OFFICIAL SUPPLIER TO ISWE Arbor Assays and the International Society of Wildlife Endocrinology (ISWE) signed an exclusive agreement for Arbor Assays to supply ISWE members with EIA kits for wildlife conservation research. DetectX, ThioStar and the Arbor Assays logo are all registered trademarks. www.arborassays.com 15

BCDEFG1 2 3 4 5 6 7 8 9 10 11 12 APrinted on Forest Stewardship Council certified paper 2018 H16 K013-HX1 181010