Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

STANDARD SAMPLE INTRODUCTION

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES

Savillex Technical Note

Savillex Technical Note

Savillex Technical Note

Selection and Optimization of the Sample Introduction System

AVIO 200 ICP-OES CONSUMABLES AND SUPPLIES. Consumables and Supplies Reference Guide

ICP-OES Organics Kit Installation Instructions

Elemental Scientific. seafast S2. Elution Profiles. Elemental Scientific

Order online ne at w elme

Determination of Copper in Green Olives using ICP-OES

of applications concentric Nebulizers for a wide variety Nebulizers MeiNHard Nebulizers MicroMist Nebulizers seaspray Nebulizers

Evaluating the performance of the OneNeb Series 2 Nebulizer with PerkinElmer Optima 7/8x00 Series ICP-OES systems

Approaches to Maximize Performance and Reduce the Frequency of Routine Maintenance in ICP-MS

Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.

Guidelines for Troubleshooting and Maintenance of ICP-MS Systems. Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Lipidomic Analysis by UPLC-QTOF MS

15 cm Reservoir Tubing. 210 cm Tubing

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

AUTOMATED LIQUID HANDLING

Guidelines for Troubleshooting and Maintenance of AA Systems. Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager

HI Total Acidity Mini Titrator for Water Analysis

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Needle Gauge. Needle OD (mm) Needle ID (mm)

Analysis of Milk for Major and Trace Elements by ICP-MS

GLASS EXPANSION NEWSLETTER

New Products for Volume 28

The majority of inductively coupled

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

More accurate results.

PEEK SS Columns & Guard Columns

Gas Chromatography Syringe Selection Guide

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

experiences that matter

Technology offer: High efficiency sample introduction nebulizer

AROMA NEBULIZER MINI DATA SHEET

injections. Needle Tip 1 µl Cone 1BR

Linkam Scientific Instruments

Calibration Standards

Low-Pressure Chromium Speciation in P2O5 using the Spectro ARCOS MV ICP and the ESI SC-DX chromfast System

THOMAFLUID - Handbook III

Solutions for Liquid Handling

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles

Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A. Phone: Fax:

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

The new generation of TipOne Pipette Tips

AUTOMATED LIQUID HANDLING

Supplies and Maintenance Parts

Top Performance. Uncompromising from the bottom to the top Eppendorf Varispenser 2 and Varispenser 2x

Compressed Air Cleaning Filter Series

BETA-GLUCURONIDASE PRODUCT LINE INNOVATION THROUGH CHEMISTRY FORENSICS

Introduction to LC/MS/MS

Thermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

Guidelines for Trouble Shooting and Maintenance of ICP-OES Systems. Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager

Purification - Flash Chromatography

NEW: with integrated step counter. Count on it! The new Eppendorf Multipette M4: simple, stress-free and ergonomic

QuickSplitTM Flow Splitters

HTEC-500 and 700 Series Related

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Lateral Flow Reagent Dispenser Instruction Manual

CoQ10(Coenzyme Q10) ELISA Kit

Nebulizers. Small Volume Nebulizers

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless!

Shimadzu s Guide to Vial Selection. Not all vials are the same

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

GE Healthcare Life Sciences. Quality matters. Whatman TM filters for air monitoring

autosamplers ASI-100 and ASI-100T Autosamplers

Eppendorf Research plus. Raise the limits NEW! Order no. A /GB4/10T/1109/FEEL/PRINT64 Printed in Germany

HI Total Alkalinity Mini Titrator for Water Analysis

CAD/CAM TECHNOLOGY. DC7 Milling System

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

Raise the limits. Eppendorf Research plus

Trace Metal Characterization of Soils Using the Optima 7300 DV ICP-OES

Helping to protect you from exposure to hazardous drugs

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

HI Total Alkalinity Mini Titrator for Water Analysis

MDI. Recommended Equipment

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

cryotubes Information from Biochrom AG, May 23, 2011

Determination of available nutrients in soil using the Agilent 4200 MP-AES

Elemental Scientific. Automated Speciation. prepfast-ic Chromium Speciation for Toy Materials (EN 71-3) ICP ICPMS AA

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

CyBio Felix Your Automated Application Starts Here

Supplies and Maintenance Parts

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED

ICP-OES/ICP-MS SUPPLIES & ACCESSORIES

Purves Environmental, Inc. Since 1993

Transcription:

Elemental Scientific (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively coupled plasma instrumentation (ICPMS). The ICPMS instrument measures most of the elements in the periodic table and is used daily by many laboratories as a routine analytical tool. ESI has many products improving upon the efficiency and capabilities of the sample introductory system. Elemental Scientific also provides complete sample introduction kits for specific trace metal and non-metal applications, including semiconductor pure chemicals, environmental, clinical, organic solvents, isotope ratio, and many other types of trace metal determinations. Shipping: All shipments are shipped via Federal Express unless otherwise requested. Shipments within the United States are F.O.B. origin. End Users are subject to shipping charges indicated on their invoice. For more information, call ESI s customer service. Terms: Terms of payment are net 30 days with purchase order. MasterCard, Visa, and American Express are accepted. Terms and pricing are subject to change without notice. Custom Products: We welcome the opportunity to manufacture special products and to work with prototype designs. This catalog is designed to be a reference for ordering ESI products. If there is more information needed, please call our staff for assistance. Ordering Information You may contact us via phone, fax, e-mail, or through our website. U.S. Business Hours: Central Time Zone Monday through Friday 8:00am to 6:00 pm Address: 1500 North 24th Street Omaha, NE 68110 USA Phone: 402.991.7800 Fax: 402.991.7799 E-Mail: esi@icpms.com Website: www.icpms.com

Table of Contents: PFA-Pt Sample Introduction Kit... 1 Micro-Flow PFA Nebulizers... 2 Teflon Sample Probes... 3-4 Apex High Sensitivity Upgrade... 5 Apex Shelves... 6 PC 3 Peltier-Cooled Cyclonic Chamber... 6 Cyclonic Spray Chambers... 7 SC-2 Autosampler... 7-8 Autosampler Clean Enclosure and STAND... 8-9 Autosampler Racks... 10-11 PFA Vials and Tubes... 12 Platinum ICP Cones... 13 PFA Pipette Tips... 13

PFA-Pt kit for PE ELAN Complete high purity sample introduction system for PE ELAN and ELAN DRC ICPMS. All wetted surfaces Teflon and Pt are used by the majority of PE ELAN semiconductor labs worldwide for the analysis of semiconductor grade chemicals and Si wafer samples. Includes 2 PFA Micro-Flow Nebulizers, PureCap PFA endcap with additional gas port, PFA spray chamber, Pt injector and quartz torch. Bayonet Torch Mount O-ring free PFA-Pt Kit...ES-2171-1472 Standard PFA-Pt Kit...ES-2171-0472 Cassette Torch Mount* O-ring free PFA-Pt Kit...ES-2171-2472 Standard PFA-Pt Kit...ES-2171-3472 ES 2171-1472 (nebulizer not shown) ELAN PFA Endcap and Spray Chamber PFA spray chamber and PureCap endcap delivers low blanks. Operates at low sample flow rates. Features secure, o-ring-free seals for low maintenance and long life-time. Second orthogonal gas port for adding an additional or mixed gas to spray chamber. Interfaces with any 6mm nebulizer. Includes addition gas line and drain line. 47mm PFA PureCap endcap...es-5010-0470 PFA Spray Chamber...ES-2100-0471 Endcap and spray chamber...es-2100-5472 Platinum injector Precision injector mounted in a PFA base for precise alignment of torch and injector. Low aluminum blanks even when high concentrations of HF are analyzed. 2mm Pt injector (Bayonet Mount) for O-ring-free torch...es-1113-1200 for standard torch...es-1113-0200 2mm Pt injector (Cassette Mount*) for O-ring-free torch...es-1113-2200 for standard torch...es-1113-3200 Many sizes of sapphire and quartz injectors are available. Quartz torch Precision alignment of torch and injector eliminates injector wobble and off-axis deflection. Direct replacement for the standard PE ELAN torch. O-ring-free seal for reduced contamination and easy maintenance O-ring-free torch... ES-1102-1000 Standard torch... ES-1102 Standard vs. O-ring-free injectors *Cassette mount injectors are found on PE ELANs newer than mid-2005. esi@icpms.com 1 Fax: 402.991.7799

High Efficiency Micro-Flow Nebulizers PFA Micro-Flow nebulizers are constructed entirely from chemically resistant fluoropolymers, ideal for strong acids, alkalis, organics, high salt solutions, and high solid concentrations. They are resistant to clogging, are reliably selfaspirated or pumped, and produce a fine aerosol for high transport efficiency and high sensitivity. PFA-ST Nebulizer High purity, HF-resistant, high performance self-aspirating nebulizer with detachable sample capillary. May be pumped from 0.1 to 2.0 ml/min. Many types of optional Teflon sample capillaries and autosampler probes are also available for the PFA ST Nebulizer. PFA-ST Nebulizer: ES-2040-54 PolyPro-ST Nebulizer High purity, HF-resistant, high performance self-aspirating nebulizer with external 1/4-28 threaded connector. May be pumped from 0.1 to 2.0 ml/min. Many types of optional Teflon sample capillaries and autosampler probes are also available for the PolyPro-ST Nebulizer. PolyPro-ST Nebulizer: ES-4040-54 Sample Capillaries for ST Nebulizers i.d. Part Number Measured self-aspiration rate (@1L/m Ar) 0.15 mm ES-2045 20 µl/min 0.2 mm ES-2043 50 µl/min 0.25 mm ES-2042 100 µl/min 0.3 mm ES-2047 200 µl/min 0.5 mm ES-2041 400 µl/min 0.8 mm ES-2044 700 µl/min 1.0 mm ES-2049 1 ml/min (red) (purple) (green) (yellow) (orange) (blue) (gray) High Efficiency PFA Micro-Flow Nebulizers PFA Nebulizers with Integrated Capillaries These nebulizers allow self-aspiration at low sample consumption rates. The unique design eliminates connectors between the sample and the nebulizer, minimizing contamination and dead volume. Since the sample contacts only Teflon, the PFA Micro-Flow nebulizer is the cleanest, most chemically resistant nebulizer available. Model Part No. Measured self- aspiration rate (@ 1L/m Ar) Model Part No. Measured self- aspiration rate (@ 1L/m Ar) PFA-100 ES-2002 100 µl/min PFA-20 ES-2020 20 µl/min PFA-50 ES-2000 50 µl/min PFA-200 ES-2003 200 µl/min PFA-400 ES-2005 400 µl/min For custom flow rates, please contact ESI. esi@icpms.com 2 Fax: 402.991.7799

PFA Nebulizers with Integrated Sampling Probes These nebulizers allow self-aspiration at low sample consumption rates with any autosampler while providing the same benefits of the PFA Micro-Flow nebulizer. The integrated sampling probe is constructed by encapsulating a rigid support material between layers of Teflon to provide a chemically resistant probe that is mechanically stable and resilient. Last three digits of part number = distance from nebulizer to the probe support (cm). Standard lengths are 80 cm (-080), 100 cm (-100), 120 cm (-120), 150 cm (-150). Probes can be custom-made to your specifications of length and materials at no extra charge. PEEK support Model PE AS-9x ESI SC (Short) ESI SC (Long) ASX-100 ASX-500 PFA-20 ES-2020-3500-080 ES-2020-3500-150 ES-2020-0100-080 PFA-50 ES-2000-9503-LLL ES-2000-3500-080 ES-2000-3500-150 ES-2000-0100-080 ES-2000-0500-080 PFA-75 ES-2001-9503-LLL ES-2001-3500-080 ES-2001-3500-150 ES-2001-0100-080 ES-2001-0500-080 PFA-100 ES-2002-9503-LLL ES-2002-3500-080 ES-2002-3500-150 ES-2002-0100-080 ES-2002-0500-080 PFA-200 ES-2003-9503-LLL ES-2003-3500-080 ES-2003-3500-150 ES-2003-0500-080 PFA-400 ES-2005-9503-LLL ES-2005-3500-080 ES-2005-3500-150 ES-2005-0500-080 Carbon Fiber support Model PE AS-9x ESI SC (Short) ESI SC (Long) ASX-100 ASX-500 PFA-20 ES-2020-3503-080 ES-2020-3503-150 PFA-50 ES-2000-9500-LLL ES-2000-3503-080 ES-2000-3503-150 ES-2000-0503-080 PFA-75 ES-2001-9500-LLL ES-2001-3503-080 ES-2001-3503-150 ES-2001-0503-080 PFA-100 ES-2002-9500-LLL ES-2002-3503-080 ES-2002-3503-150 ES-2002-0503-080 PFA-200 ES-2003-9503-LLL ES-2003-3503-080 ES-2003-3503-150 ES-2003-0503-080 PFA-400 ES-2005-9503-LLL ES-2005-3503-080 ES-2005-3503-150 ES-2005-0503-080 Ultem support Model PE AS-9x ESI SC (Short) ESI SC (Long) ASX-100 ASX-500 PFA-20 ES-2020-3505-080 ES-2020-3505-150 ES-2020-0105-080 PFA-50 ES-2000-9505-LLL ES-2000-3505-080 ES-2000-3505-150 ES-2000-0105-080 ES-2000-0505-080 PFA-75 ES-2001-9505-LLL ES-2001-3505-080 ES-2001-3505-150 ES-2001-0105-080 ES-2001-0505-080 PFA-100 ES-2002-9505-LLL ES-2002-3505-080 ES-2002-3505-150 ES-2002-0105-080 ES-2002-0505-080 PFA-200 ES-2003-9503-LLL ES-2003-3505-080 ES-2003-3505-150 ES-2003-0505-080 PFA-400 ES-2005-9503-LLL ES-2005-3505-080 ES-2005-3505-150 ES-2005-0505-080 esi@icpms.com 3 Fax: 402.991.7799

Autosampler Probes for ST Nebulizers ST Nebulizer probes connect directly to any ST-type nebulizer. The 1/4-28 threaded fitting provides a secure, zero-dead-volume connection with no additional fittings required. Last three digits of part number = distance from flanged fitting to the probe support (cm). 80 cm (-080) 100 cm (-100) 120 cm (-120) 150 cm (-150) Probes can be custom-made to your specifications of length and materials at no extra charge. PEEK Support Probe I.D. PE AS-9x ESI-SC (Short) ESI-SC (Long) ASX-100 ASX-500 0.15mm ES-5017-9150-LLL ES-5017-3150-080 ES-5017-3150-150 ES-5016-0150-080 ES-5017-0150-150 0.20mm ES-5017-9200-LLL ES-5017-3200-080 ES-5017-3200-150 ES-5016-0200-080 ES-5017-0200-150 0.25mm ES-5017-9250-LLL ES-5017-3250-080 ES-5017-3250-150 ES-5016-0250-080 ES-5017-0250-150 0.30mm ES-5017-9300-LLL ES-5017-3300-080 ES-5017-3300-150 ES-5016-0300-080 ES-5017-0300-150 0.50mm ES-5017-9500-LLL ES-5017-3500-080 ES-5017-3500-150 ES-5017-0500-150 0.80mm ES-5017-9750-LLL ES-5017-3750-080 ES-5017-3750-150 ES-5017-0750-150 Carbon Fiber Support Probe I.D. PE AS-9x ESI-SC (Short) ESI-SC (Long) ASX-100 ASX-500 0.15mm ES-5037-9150-LLL ES-5037-3150-080 ES-5037-3150-150 ES-5037-0150-150 0.20mm ES-5037-9200-LLL ES-5037-3200-080 ES-5037-3200-150 ES-5037-0200-150 0.25mm ES-5037-9250-LLL ES-5037-3250-080 ES-5037-3250-150 ES-5037-0250-150 0.30mm ES-5037-9300-LLL ES-5037-3300-080 ES-5037-3300-150 ES-5037-0300-150 0.50mm ES-5037-9500-LLL ES-5037-3500-080 ES-5037-3500-150 ES-5037-0500-150 0.80mm ES-5037-9750-LLL ES-5037-3750-080 ES-5037-3750-150 ES-5037-0750-150 Ultem Support Probe I.D. PE AS-9x ESI-SC (Short) ESI-SC (Long) ASX-100 ASX-500 0.15mm ES-5057-9150-LLL ES-5057-3150-080 ES-5057-3150-150 ES-5056-0150-080 ES-5057-0150-150 0.20mm ES-5057-9200-LLL ES-5057-3200-080 ES-5057-3200-150 ES-5056-0200-080 ES-5057-0200-150 0.25mm ES-5057-9250-LLL ES-5057-3250-080 ES-5057-3250-150 ES-5056-0250-080 ES-5057-0250-150 0.30mm ES-5057-9300-LLL ES-5057-3300-080 ES-5057-3300-150 ES-5056-0300-080 ES-5057-0300-150 0.50mm ES-5057-9500-LLL ES-5057-3500-080 ES-5057-3500-150 ES-5057-0500-150 0.80mm ES-5057-9750-LLL ES-5057-3750-080 ES-5057-3750-150 ES-5057-0750-150 esi@icpms.com 4 Fax: 402.991.7799

Fully-integrated, high-sensitivity sample introduction systems for ICP spectroscopy. Designed to increase signal intensity while reducing relative background contamination for ICPMS analyses. When combined with a self-aspirating Micro-Flow PFA nebulizer even aggressive and concentrated chemicals may be analyzed at very high sensitivity with low blank contamination. Apex Q for PE ELAN Apex High Sensitivity Inlet System High-sensitivity, low-flow sample introduction system for ICPMS. Improves sample transport efficiency while maintaining low blanks. Includes PFA-100 and PFA-ST nebulizers, integrated peristaltic drain pump, and connectors to adapt to the PE ELAN. Apex Q for ELAN...ES-4354-1000-21 Apex HF for PE ELAN All PFA sample flow path. High-sensitivity, low-flow HF-resistant sample introduction system for ICPMS. Recommended to be used with the Apex shelf. Includes PFA-100 and PFA-ST nebulizers, integrated peristaltic drain pump, and connectors to adapt to the PE ELAN. Apex HF for ELAN...ES-4454-1000-20 Spiro Teflon Membrane Desolvator Designed for use with or without the Apex system. Innovative design allows for direct analysis of a variety of samples, including high concentration Si samples and volatile organic solvents. The Spiro is an extremely stable membrane desolvator compatible with many types of high dissolved solids samples. The Spiro removes Si on-line as SiF 6 after addition of HF to the sample, allowing the determination of trace metal impurities in Si matrices without ICPMS cone clogging or off-line sample preparation. The Spiro combined with the Apex system is useful for direct analysis of neat organic chemicals, such as methanol, acetone and other solvents. Since the Spiro removes volatile species from the sample aerosol stream, it is not recommended for the determination of volatile analytes, including boron. Spiro Membrane Desolvator...ES-4599-3000 The Spiro attaches directly to the Apex. esi@icpms.com 5 Fax: 402.991.7799

Apex Shelves for ELAN ICPMS Polypropylene shelves for direct mounting of the Apex system to the ELAN ICPMS injector. A notch in the bottom of each shelf fits directly over the ridge in the built-in ELAN tray. Apex Shelf for PE ELAN with bayonet torch for PE ELAN 6100, DRC, 9000 before mid-2005...es-2999-5431 Apex Shelf for PE ELAN with cassette torch for PE ELAN newer than mid-2005...es-2999-5421 PC 3 Peltier Cooler for Cyclonic Spray Chambers The PC 3 is a small and robust Peltier cooler for ICPMS cyclonic spray chambers. The cyclonic spray chamber offers the advantages of low-memory effects, fast rinse-out, and higher sample transport efficiency. The PC 3 cools the outer walls of the cyclonic spray chamber to a constant temperature enhancing long-term signal stability, reducing polyatomic ion interferences, such as oxides, and reducing solvent loading when volatile organic solvents are analyzed. PC 3 kit with Quartz spray chamber and addition gas port...es-4152-1111-16 PC 3 kit with PFA spray chamber and addition gas port...es-4152-3111-16 The PC3 can be adapted to a wide variety of ICP injectors, including ESI PFA injector base and quartz ball joint injector. The PC3 shown here is connected to the ELAN injector normally used with the PE Ryton spray chamber. esi@icpms.com 6 Fax: 402.991.7799

O-ring-free Cyclonic Spray Chambers Cyclonic spray chambers offer the advantages of low-memory effects, fast rinse-out, and higher sample transport efficiency. O-ring-free connections to the nebulizer and injector eliminate a possible source of contamination. These spray chambers can be used with any 6mm nebulizer, including Micro-Flow PFA Nebulizers, PolyPro Nebulizers, and glass concentric nebulizers. Quartz spray chamber with addition gas port... ES-3154-1111-16 PFA spray chamber with addition gas port... ES-3154-3111-16 A one piece ferrule nut holds any 6mm nebulizer in place *All ESI cyclonic spray chambers may be used alone or with the PC 3 Peltier Cooler. SC-2 Ultraclean Optically Encoded Autosampler Automatic sampling while maintaining sample integrity and purity. Improved control of self-aspiration, reducing "vapor-locks" and useful for low flow applications and organic solvents analysis. Demonstrably improves rinseout and background over any other autosampler available for ELAN ICPMS. Recently improved for chemical resistance to high acid concentrations in enclosed environments. Fully compatible with ELAN software. SC-2 Autosampler... SC-8102-1000 esi@icpms.com 7 Fax: 402.991.7799

SC-FAST high purity sample injection The SC-FAST integrates fully with the SC-2 autosampler to ensure the fastest sample throughput of any commercial sample introduction system. Through use of an injection valve system, most of the uptake and rinse time can be eliminated, increasing throughput up to 2-3 fold without loss of analytical performance. SC-FAST upgrade...sc-0500-02 SC-FAST can be integrated to the bottom of the SC-2 for ELAN Semiconductor rinse stations and delivery Dual pressurized containers deliver the rinse solution to the SC Autosampler dual-flowing rinse stations without the use of a peristaltic pump, eliminating a source of contamination. All wetted parts are made from PFA Teflon to ensure the cleanest possible rinse. PFA Rinse Delivery System...SC-0304-03 Upgrade options for SC-2 Autosampler Sample enclosure for SC-2 autosampler Controls evaporation and environmental contamination. Only the sample area is enclosed allowing free access to the rest of the instrument. The large flexible door opens easily for access to the sample racks and locks securely closed. Sample enclosure...sc-1207-0200 esi@icpms.com 8 Fax: 402.991.7799

ULPA Filtered enclosure for SC-2 Autosampler The actively filtered ULPA Clean Enclosure is available for environments where the highest degree of clean air must be maintained. ULPA (Ultra Low Penetration Air) filter technology removes 99.999% of airborne particles as small as 0.12 micron. Sample enclosure... SC-1207-1200 ULPA (Ultra Low Penetration Air) filter technology removes 99.999% of airborne particles as small as 0.12 micron. Two airflow speed settings provide an airflow up to 1 cubic meter per minute. Filter has a 5 year lifetime if situated in a clean room (1 year lifetime in non-clean room environments). ULPA Filter... SC-0602 SC-2 STAND The combination of the SC-2 autosampler with STAND option provides an optimized sample changer for the ELAN ICPMS. The stand positions the SC-2 at an ideal height next to the ELAN ICPMS, minimizing the distance between the sample and the nebulizer for faster uptake and rinse-out. The SC-2 STAND also eliminates the need for a separate autosampler table and includes two shelves with storage space. SC-2 STAND...SC-1210-0002 The STAND option can be used either with the SC-2 autosampler alone or combined with the SC-FAST sample injection system esi@icpms.com 9 Fax: 402.991.7799

Sample Racks for SC-2 MR-21-14 21 position 3x7 mini rack. For "GFAA" style vials. MR-00-01 Cover for Micro Racks. MT-24G 24 position 4x6 GeMeTec rack. Compatible with GeMeTec automated VPD system. MT-24G-AP GeMeTec adapter plate. Adapts GeMeTec rack to microtiter plate locations on the SC-2 autosampler. The SC autosampler readily accommodates a wide variety of sample racks for both small and large volume sample analysis. Many other sizes and types of racks are available. Please contact ESI for racks compatible with vials that you prefer to use. esi@icpms.com 10 Fax: 402.991.7799

Sample Racks for SC-2 ST10-28 10 position standards rack. For 25 ml PFA bottles. SR2-21-27 21 position 3x7 super rack. For 25 ml PFA bottles SR2-12-50 12 position 2x6 super rack. For 125 ml PFA bottles The SC autosampler readily accommodates a wide variety of sample racks for both small and large volume sample analysis. Many other sizes and types of racks are available. Please contact ESI for racks compatible with vials that you prefer to use. esi@icpms.com 11 Fax: 402.991.7799

Sample Vials and Bottles for SC-2 V-15-0311-CG-X 1.5mL PFA GFAA style vial (press-on cap not included) V-15-0312-CG-X 2.5mL PFA GFAA style vial (press-on cap not included) V-15-0313-CG-X 4mL PFA GFAA style vial, (press-on cap not included) V-14-0300-X V-14-0301-X Snap-on seal caps for GFAA style vials (left) Dust protection caps for GFAA style vials (right) V-27-0360 25mL PFA bottle with PFA seal and PFA screw cap V-50-0360 125mL high purity PFA bottle with seal and screw cap. Recommended for DI water and high purity semiconductor-grade chemicals due to favorable sample volume to surface area ratio. esi@icpms.com 12 Fax: 402.991.7799

ICPMS Platinum Cones for ELAN Platinum Cones ES-3000-1711 Pt Sampler cone ES-3000-1712 Pt Skimmer cone Nickel Cones ES-3000-1709 ES-3000-1710 Ni Sampler cone Ni Skimmer cone ELAN 6000/6100/9000/DRC Cones PFA Pipette Tips for Eppendorf Type Pipetters 100 µl PFA Pipette Tips Quantity of 10, pre-cleaned: Quantity of 96, pre-cleaned: ES-7000-0101 ES-7000-0111 1000 µl PFA Pipette Tips Quantity of 10, pre-cleaned: Quantity of 60, pre-cleaned: ES-7000-1001 ES-7000-1011 esi@icpms.com 13 Fax: 402.991.7799