Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Similar documents
IMRT Implementation And Patient Specific Dose Verification With Film And Ion Chamber Array Detectors

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams

Leila E. A. Nichol Royal Surrey County Hospital

Volumetric Modulated Arc Therapy - Patient Specific QA

IMRT point dose measurements with a diamond detector

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Evaluating Pre-Treatment IMRT & VMAT QA Techniques Using Receiver Operating. Characteristic (ROC) Analysis. Allison Lorraine Mitchell

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Small field diode dosimetry

EPID dosimetry confi guration and pre-treatment IMRT verifi cation

An Active Matrix Flat Panel Dosimeter AMFPD for in-phantom dosimetric measurements

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

MEDICAL PHYSICS INTERNATIONAL Journal, vol.3, No.2, 2015 HOW TO

IMRT QA: Point Dose Measurements or 2D Array?

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

EPID dosimetry for pretreatment quality assurance with two commercial systems

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Use of Electronic Portal Image Detectors for Quality Assurance of Advanced Treatments

Pre-treatment verification for IMRT / IGRT and Rotational therapy

Limits of Precision and Accuracy of Radiation Delivery Systems

A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy

Measurement Guided Dose Reconstruction (MGDR) Transitioning VMAT QA from phantom to patient geometry

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times

The MapCHECK Measurement Uncertainty function and its effect on planar dose pass rates

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Diode calibration for dose determination in total body irradiation

Electron Beam ET - Reloaded Therapy - Reloaded

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany

GAMMA DOSE DISTRIBUTION EVALUATION OF XiO TREATMENT PLANNING SYSTEM FOR STATIC FIELD IMRT, USING AAPM TG-119

GAMMA DOSE DISTRIBUTION EVALUATION OF XiO TREATMENT PLANNING SYSTEM FOR STATIC FIELD IMRT, USING AAPM TG-119

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

EPID-based dosimetry to verify IMRT planar dose distribution for the as1200 EPID and FFF beams

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms

biij Patient-specific quality assurance of RapidArc treatments: Portal prediction dosimetry compared with phantom studies Krishna Murthy K *

Clinical Implications of High Definition Multileaf Collimator (HDMLC) Dosimetric Leaf Gap (DLG) Variations

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit

REPLACING PRETREATMENT VERIFICATION WITH IN VIVO EPID DOSIMETRY FOR PROSTATE IMRT

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Unrivaled, End-to-End

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

Dosisverifikation mit Delta 4 Discover während der Behandlung

Online Care, Online Control, Online Confidence

Pre-treatment and in-vivo dosimetry of Helical Tomotherapy treatment plans using the Dosimetry Check system

Hampton University Proton Therapy Institute

Digital film dosimetry in radiotherapy and the development of analytical applications software

Follow this and additional works at:

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Patient-specific quality assurance for intracranial cases in robotic radiosurgery system

Patient and Linac QA - present and the future

Efficient Dosimetry for Proton Therapy

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Eric E. Klein, Ph.D. Chair of TG-142

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

IMRT pre-treatment verification basic approaches

The impact of continuously-variable dose rate VMAT on beam stability, MLC positioning, and overall plan dosimetry

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

Additional Questions for Review 2D & 3D

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Acrylonitrile Butadiene Styrene (ABS) plastic-based low cost tissue equivalent phantom for verification dosimetry in IMRT

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Portal dosimetry in wedged beams

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Intensity Modulated RadioTherapy

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Dosimetric characteristics of intensity-modulated radiation therapy and RapidArc therapy using a 3D N-isopropylacrylamide gel dosimeter

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Activity report from JCOG physics group

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Application(s) of Alanine

Amendment No. 2. Item No. 2 (Rfx/ Event number )

Verification of Advanced Radiotherapy Techniques

Quality assurance in external radiotherapy

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Optimized Varian asi portal dosimetry: development of datasets for collective use

Dosimetric verification and quality assurance of runningstart-stop (RSS) delivery in tomotherapy

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Transcription:

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 11, NUMBER 2, SPRING 2010 Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification Sathiyan Saminathan, a Ravikumar Manickan, Varatharaj Chandraraj, Sanjay. S. Supe Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore, India ssathiyan@rediffmail.com Received 1 April, 2009; accepted 2 January, 2010 Intensity-modulated radiotherapy treatment demands stringent quality assurance and accurate dose determination for delivery of highly conformal dose to the patients. Generally 3D dose distributions obtained from a treatment planning system have to be verified by dosimetric methods. Mainly, a comparison of two-dimensional calculated and measured data in several coplanar planes is performed. In principle, there are many possibilities to measure two-dimensional dose distributions such as films, flat-panel electronic portal imaging devices (EPID), ion chambers and ionization chamber arrays, and radiographic and radiochromic films. The flat-panel EPIDs show a good resolution and offer a possibility for real-time measurements: however to convert the signal into dose, a separate commercial algorithm is required. The 2D ion chamber array system offers the real-time measurements. In this study, dosimetric characteristics of 2D ion chamber array matrix were analyzed for verification of radiotherapy treatments. The dose linearity and dose rate effect of the I matrixx device was studied using 6 MV, 18 MV photons and 12 MeV electrons. The output factor was estimated using I matrixx device and compared with ion chamber measurements. The ion chamber array system was found to be linear in the dose range of 2 500 cgy and the response of the detector was found to be independent of dose rate between 100 MU/min to 600 MU/min. The estimated relative output factor with I matrixx was found to match very well with the ion chamber measurements. To check the final dose delivered during IMRT planning, dose distribution patterns such as field-in-field, pyramidal, and chair tests were generated with the treatment planning system (TPS) and the same was executed in the accelerator and measured with the I matrixx device. The dose distribution pattern measured by the matrix device for field-in-field, pyramidal, and chair test were found to be in good agreement with the calculated dose distribution by TPS both for 6 and 18 MV photons (γ 1: 96%, criteria 3%, 3 mm). Two 7-field IMRT plans (one prostate, one head and neck) dose distribution patterns were also measured with I matrixx device and compared with film dosimetry. The measurements and evaluation proves that I matrixx can be used for quantifying absolute dose. Moreover, using I matrixx as absolute dosimeter in IMRT field verification, avoids the time-consuming procedure of making ionometric measurement for absolute dose estimation and film for dose distribution verification. The I matrixx can also used for routine quality assurance checks like flatness, symmetry, field width, and penumbra of the linear accelerator beam. PACS number: 87.55.ne and 87.56.Fc Key words: ion chamber array, intensity-modulated radiotherapy, fluence, film dosimetry a Corresponding author: S. Sathiyan, Asst. Professor of Radiation Physics, Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore 560 029, India; phone: 0091-80- 2609 4050; fax: 0091-80- 26560723; email: ssathiyan@rediffmail.com 116 116

117 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 117 I. Introduction Intensity-modulated fields have the potential to deliver optimum dose distributions which results in greater dose uniformity in the target and lower doses to the neighboring critical organs and normal healthy structures, as compared to conventional external beams employing wedges and cerroband blocks. Multileaf collimator (MLC)-based intensity-modulated radiation therapy (IMRT) can be delivered by two main modalities, namely segmental IMRT (step and shoot) and dynamic IMRT (sliding window). In the step-and-shoot modality, the MLC shape remains constant while the beam is on and changes while the beam is off in the sliding window, each leaf pair moves continuously, unidirectionally, and with independent speed while the beam is on. Any shape of intensity profile can be obtained by controlling the leaf movement, subject to the mechanical constraints such as leaf width, maximum speed and field size etc. imposed by the multileaf collimator (MLC) system. As leaf motions are controlled by a computer, the IMRT technique lends itself to automated treatment delivery, eliminating the need for re-entry into the room between fields. During treatment, the leaf positions are verified by computer, ensuring better quality control than when using customized field shaping blocks. (1) The implementation of IMRT in external beam therapy imposes high demands on measurement device and quality assurance. Generally three-dimensional dose distributions obtained from a treatment planning system have to be verified by dosimetric means. Mainly a comparison of two-dimensional calculated and measured data in several coplanar planes is performed. (2) The in vivo determination of dose distribution inside the patient is complicated and error-prone, while the pretreatment verification in phantom seems to be easier and more reliable. The option of the treatment planning systems that permits exporting the true radiation fields (specific for single patient) on a quality assurance phantom provides verification of the treatment delivery on a field-by-field basis. (3) There are many possibilities to measure two-dimensional dose distributions. The film dosimetry is a well-established method to verify dose distributions in phantom. (4,5) Film dosimetry permits high spatial resolution, limited only by the reading system, so that it is commonly used for measuring beam profiles and isodose curves. On the other hand, it shows a rather small dynamic range together with a nonlinear and energy dependent dose response. Moreover, film dosimetry is a very time consuming procedure if an acceptable level of accuracy is required in absolute dose determination. Radiographic and radiochromic films cannot be applied for fast real-time measurements because their calibration and scanning processes are time-consuming. (2) Flat-panel electronic portal imaging device (EPID) was studied by Warkentin et al. (6) It has shown good resolution and offers a possibility for real-time measurements. Nicolini et al. (7,8) have described the GLAaS algorithm for pretreatment IMRT absolute dose verification based on the use of amorphous silicon detectors. They have concluded that the PV-as500 detector with GLAaS algorithm is a reliable method of estimating the absolute dose. The ionization chamber array (9) is capable of providing real-time measurement and it can be easily connected to a PC with a standard Ethernet cable. The dose can be measured directly, after calibration of the ionization chamber array. Though their resolution is less, compared to that of films or EPIDs, good dosimetric agreement was noticed between films and 2-D ionization chambers for verification of radiotherapy plans, as reported by Spezi et al. and Stasi et al. (10,11) Due to its properties, it qualifies for measuring dynamic process, e.g. dynamic wedges, dynamic IMRT. This study was carried out to evaluate the dosimetric performance of 2D ionization chamber array for IMRT dose verification. To quantify the performance of the device, some of the basic dosimetry tests were carried out and also some of the tests were compared with the ionization chamber measurements in phantom. The basic tests included output factor, dose linearity, and dose rate behavior. The measurements carried out by the I matrixx device for verification of IMRT plans are also presented, and the same was compared with the film dosimetry measurements.

118 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 118 II. Materials and Methods The I matrixx device consists of a 1020 vented ion chamber detectors, arranged in a 32 32 grid. When irradiated, the air in the chambers is ionized. The released charge is separated by means of an electrical field between the bottom and the top electrodes. The current, which is proportional to the dose rate, is measured and digitized by a non-multiplexed 1020 channels current sensitive analog to digital converter. The each chamber volume is 0.08 cm 3 with the height of 5 mm and diameter of 4.5 mm. The spatial resolution of the detector system is 7.5 mm. The OmniPro IMRT software can able to give 1 mm resolution with linear interpolation using low pass filter. The maximum dose rate detectable by the detectors are 5 Gy/min and minimum detectable dose rate is 0.1 Gy/min. (12) The bias voltage required for the I matrixx system is 500 ± 30 V. The equivalent absorber thickness on the front side of the matrix is 3.6 mm. The maximum field of view is 24 24 cm 2. Before taking the measurement, the device requires a 15 min warm-up time. The detector panels are cooled by forced air cooling via two fans. The device runs with two separate counters to avoid dead time, the minimum sampling period is 20 mins. The matrix device can be directly connected to the PC via standard ethernet interface to acquire the measurement. The measurements were performed in Clinac DHX linear accelerator with 6 and 18 MV photons and 12 MeV electrons. The I matrixx was irradiated with 10 10 cm 2 field size and source to effective point of measurement (3.6 mm from surface) distance was maintained as 100 cm with 5 cm solid water (RW3) phantom as a buildup material and 5 cm solid water as a backscatter material (Fig. 1). Fig. 1. Measurement setup at the accelerator with I matrixx. A. Dose and dose rate dependence The dose linearity test was performed using 6 and 18 MV X-ray photons by irradiating I matrixx device with 10 10 cm 2 field size. The measurements were carried out at 100 cm FSD and the detector plane was maintained at 5 cm depth. The detector linearity was verified by measuring the I matrixx output for 2, 3, 5, 10, 20, 50, 100, 200, 300 and 500 MUs set on the accelerator console. The dose rate effect dependency of I matrixx was tested for both 6 and 18 MV photons for different dose rates ranging from 100 MU/min to 600 MU/min for the same set monitor unit on the console. The dose and dose rate effect of I matrixx was also tested with 12 MeV electrons at reference depth (2.89 g/cm 2 ) using an applicator of 15 15 cm 2.

119 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 119 B. Output factor The normalized output factor was estimated using I matrixx device by maintaining 100 cm FSD and positioning the detector plane at 5 cm depth. Efficiently this test assessed the scatter properties of the I matrixx detectors, which depend on the internal design of the device. The response of 2D ion chamber array for a small radiation beams was of particular interest because of its potential applications to the verification of IMRT plans. The output factor measurements were carried out by delivering 100 MU for square field sizes ranging from 3 3 cm 2 to 24 24 cm 2. The I matrixx signal was averaged over the 2 2 central pixels which cover the area of the central four reference ionization chambers. Dose outputs were compared with ion chamber measurements carried out with the same geometry using RW3 solid water phantom. C. Comparison between dose distributions calculated by Eclipse planning system and measured with the I matrixx and film dosimetry system In order to verify an IMRT plan, a verification plan was produced for every original plan in the treatment planning system. The CT data of the measurement system was used to estimate the dose distribution at depth for these verification plans. The I matrixx device with 5 cm solid water phantom positioned above and below was scanned with 2 mm CT slice thickness. The verification plan was exported to the scanned detector system with the detector plane positioned at isocentre. In the verification plan, all the fields used for the planning where set at 0 degree gantry and collimator angles. The central beam was made perpendicular to the I matrixx measurement level at the center of the measurement area. Within the treatment field, the dose at the detector plane was calculated and transferred to OmniPro IMRT software for comparison. Every verification field was exported to the accelerator console, and the same was delivered and measured by the I matrixx device. All individual field delivered dose distribution patterns were added to obtain the composite dose distribution, and the same was compared with the TPS generated composite dose distribution using the Gamma Index Method. The spatial difference in the dose distribution (Distance-To-Agreement) and the dose deviation (Delta-Dose) are verified with the Gamma Index Method at a particular point simultaneously. The generated resulting matrix gives the value of Gamma Index for every tested measurement points. If this value is smaller than or equal to 1, the criteria values are not exceeded. When the Gamma Index value is higher than 1, the measurement result lies outside the tolerance range. The measurement was also carried out in the solid water phantom (RW3) using EDR2 verification film. The film was positioned at 5 cm depth in solid water phantom with 10 cm of scattering material present at the bottom. The above phantom set was CT scanned similar to I matrixx phantom to create a verification plan in the Eclipse treatment planning system. Similarly, the test patterns generated by treatment planning system, like chair test and pyramidal test, were exported to verification phantoms for quantitative evaluation with I matrixx and film dosimetry systems. Two 7-field IMRT plans (one prostate, one head and neck) were also considered for comparing the calculated and measured dose distributions. III. Results & DISCUSSION A. Dose and dose rate dependence The response of the I matrixx device (arbitrary units) was found to be linear with dose in the clinically useful range of 2 to 500 MU for both 6 and 18 MV photons and 12 MeV electrons (Fig. 2 (a), (b), (c)). Also, the I matrixx array detectors were found to be independent of dose rate between 100 MU/min to 600 MU/min for both 6 and 18 MV photons and 12 MeV electrons (Fig. 3). The observed results were in close agreement with ion chamber measurements. As the response of the I matrixx device is linear with dose and dose rate, it can be used for the measurement of dose gradients effectively.

120 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 120 (a) (b) (c) Fig. 2. The signal of the I matrixx detector for different number of monitor units for: a) 6 MV photons; b) 18 MV photons; c) 12 MeV electrons.

121 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 121 Fig. 3. The signal of I matrixx detector for different dose rates for 6 and 18 MV photons and 12 MeV electrons. B. Output factor The output factors estimated using the array detectors were found to be in close agreement with the output factors measured using 0.6 cm 3 ionization chamber (Fig. 4 (a), (b)) for 6 MV and 18 MV photons. The measured output factor for 12 MeV electrons were also in close agreement with the parallel plate ionization chamber measurement. Small discrepancies of the order of ± 0.5% noticed could be due to the scatter arising from the components of I matrixx.

122 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 122 (a) (b) Fig. 4. Output comparison between I matrixx ( ) and ion chamber measurements ( b) 18 MV photons. ) for: a) 6 MV photons; C. Comparison between dose distribution calculated by Eclipse planning system and measured with the I matrixx and film dosimetry system Figures 5(a) and (b) show comparison of TPS calculated and measured chair test pattern by I matrixx and film dosimetry system. Comparison of TPS generated dose distribution with the dose distribution measured using film has resulted in the pixel match of 97.13% with γ 1, and a pixel match of 97.86% with γ 1 was noticed for TPS and I matrixx dose distribution pattern (for 3% delta dose and 3 mm DTA). Figures 6(a) and (b) show comparison of TPS calculated and measured pyramid test pattern by I matrixx and film dosimetry system. The pixel match of 96.67% for γ 1 was observed for dose distribution generated using TPS generated and measured with film. The pixel match of 96.36% with γ 1 was noticed between TPS generated and I matrixx measured dose distribution pattern (3% delta dose and 3 mm DTA). Figures 7(a) and (b) show the comparison of measured and calculated dose distribution pattern for seven-field prostate patient. The match result has shown 97.43% agreement for γ 1 with 3% delta dose and 3 mm DTA for TPS generated and I matrixx measured dose distribution patterns,

123 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 123 (a) Fig. 5(a). Comparison of TPS-generated and I matrixx-measured chair test pattern. (b) Fig. 5(b). Comparison of TPS-generated and film-measured chair test pattern. and 98.02% for TPS generated and film measured dose distribution patterns. Figures 8(a) and (b) show the comparison of measured and calculated dose distribution pattern for seven-field head and neck patient. The match result has shown 97.3% agreement for γ 1 with 3% delta dose and 3 mm DTA for TPS generated and I matrixx measured dose distribution patterns, and 95.13% for TPS generated and film measured dose distribution patterns. The comparison of gamma pixel match for I matrixx and film with the TPS calculated dose distribution for various test patterns are summarized in Table 1. The mismatch of high gamma value regions (> 1) could be due to the large dose gradient in the delivered dose and the limited resolution of the measuring system to detect the same.

124 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 124 Ta b l e 1. Summary of the results of gamma pixel match. Gamma Pixel Match (γ 1) for 3% Delta Dose & 3 mm DTA Chair Test (TPS vs. I matrixx) 97.86% Chair Test (TPS vs. Film) 97.13% Pyramidal Test (TPS vsx I matrixx) 96.36% Pyramidal Test (TPS vs. Film) 96.67% Prostate (TPS vs. I matrixx) 97.43% Prostate (TPS vs. Film) 98.02% Head & Neck (TPS vs. I matrixx) 97.30% Head & Neck (TPS vs. Film) 95.13% (a) Fig. 6(a). Comparison of TPS-generated and I matrixx-measured pyramid test pattern. (b) Fig. 6(b). Comparison of TPS-generated and film-measured pyramid test pattern.

125 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 125 (a) Fig. 7(a). Comparison of TPS-generated and I matrixx-measured dose distribution for seven-field prostate plan. (b) Fig. 7(b). Comparison of TPS-generated and film-measured dose distribution for seven-field prostate plan.

126 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 126 (a) Fig. 8(a). Comparison of TPS-generated and I matrixx-measured dose distribution for seven-field head and neck plan. (b) Fig. 8(b). Comparison of TPS-generated and film-measured dose distribution for seven-field head and neck plan.

127 Sathiyan et al.: Dosimetry of 2D ion chamber array matrix 127 IV. Conclusions IMRT has become one of the commonly used radical treatment technique. Presently, unless the absolute dose is measured and checked individually, the treatment outcome cannot be assessed. The 2-D ion chamber array matrix is one of the easy to use QA tool for IMRT technique. To quantify the performance of the device, some of the basic dosimetry tests were carried out and also some of the tests were compared with the ionization chamber measurements in phantom. The basic test includes dose linearity, dose rate behavior, and output factor. The performance of I matrixx device in verification of IMRT plans are also presented and compared with the film dosimetry system. The measurements and evaluation processes with I matrixx has shown that it can be used for quantifying absolute dose with the required accuracy level. As the accuracy of dose measurement with I matrixx is good, the need for depending upon time-consuming measurements with film or ion chamber can be avoided. The detecting system was found to be linear with dose and independent of dose rate. Our measurement results were comparable with the results reported in the literature. (2) The measured and TPS calculated dose distribution patterns were in good agreement for test patterns and the patient treatment plans. Though the film dosimetry system gives good resolution, it is labor-intensive procedure, whereas the I matrixx can be used as a direct reading device. The measurement with I matrixx takes less time compared to film dosimetry system for IMRT field verification. The I matrixx can also be used for routine quality assurance checks such as flatness, symmetry, field width, and penumbra checks of the linear accelerator beam. References 1. Venencia CD, Besa P. Commissioning and quality assurance for intensity modulated radiotherapy with dynamic multileaf collimator: experience of the Pontificia Universidad Catolica de Chle. J Appl Clinc Med Phys. 2004;5(3):37 54. 2. Herzen J, Todorovic M, Cermers F, et al. Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine. Phys Med Biol. 2007;52(4):1197 1208. 3. Buonamici FB, Compagnucci A, Marrazzo L, Russo S, Bucciolini M. An intercomparison between film dosimetry and diode matrix for IMRT quality assurance. Med Phys. 2007;34(4):1372 79. 4. Bucciolini M, Bounamici FB, Casati M. Verification of IMRT fields by film dosimetry. Med Phys. 2004;31(1):161 68. 5. Ju SG, Ahn YC, Huh SJ, Yeo IJ. Film dosimetry for intensity modulated radiotherapy: dosimetric evaluation. Med Phys. 2002;29(3):315 25. 6. Warkentin B, Steciw S, Rathee S, Fallone BG. Dosimetric IMRT verification with a flat-panel EPID. Med Phys. 2003;30(12):3143 55. 7. Nicolini G, Fogliata A, Vanetti E, Clivio A, Cozzi L. GLAaS : an absolute dose calibration algorithm for an amorphous silicon portal imager. Application to IMRT verifications. Med Phys. 2006;33(8):2839 51. 8. Nicolini G, Fogliata A, Vanetti E, Clivio A, Vetterli D, Cozzi L. Testing the GLAaS algorithm for dose measurements on low- and high-energy photon beams using an amorphous silicon portal imager. Med Phys. 2008;35(2):464 72. 9. Martens C, De Wagter C, De Neve W. The value of the LA48 linear ion chamber for characterization of intensitymodulated beams. Phys Med Biol. 2001;46(4):1131 48. 10. Stasi M, Baiotto B, Barboni G, Scielzo G. The behavior of several microionization chambers in small intensity modulated radiotherapy fields. Med Phys. 2004;31(10):2792 95. 11. Spezi E, Angelini AL, Romani F, Ferri A. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments. Phys Med Biol. 2005;50(14):3361 73. 12. I mrt MatriXX User Manual. Schwarzenbruck, Germany: Scanditronix Wellhofer; 2006.