Unidirectional Airflow Smoke Test Protocol

Similar documents
2013 USP Chapter <797> Compliance Survey & Current Practice Standards

Uni-directional Airflow Systems Working Height Velocity (WHV) Gordon Farquharson July 2017

STERILITY TESTING OF PHARMACEUTICAL PRODUCTS

247 CMR BOARD OF REGISTRATION IN PHARMACY

Sterility Assurance and Risk Management: A CDER Microbiologist s Perspective

Effective Airflow Visualization Studies. Gordon Farquharson, July 2017

Sterile Product Preparation for Non-Pharmacy Personnel Dennis Sinclair, R.Ph..

Talon Compounding Pharmacy 10/3/17

Parametric Release Regulatory Requirements. Terry E. Munson Technical Vice President PAREXEL International, LLC

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

A WHITE PAPER STERILITY TESTING ESSENTIAL THINGS YOU MUST KNOW

THE UNIVERSITY OF ALABAMA FUME HOOD MANAGEMENT PLAN

INSTRUCTIONS FOR CLEANING, DISINFECTION AND STERILIZATION OF DFS INSTRUMENTS

Sample Enhanced Visual Inspection of medical devices. SUBJECT: Enhanced Visual Inspection of medical devices

6/7/2017 CHANGES IN PHARMA REGULATIONS HOW IT AFFECTS THE OR NURSE DISCLOSURE OBJECTIVES

Compounding Medication Regulations

How Do You Know If a Sterilized Package Remains Sterile?

PAGE 1 OF 5 HEALTH, SAFETY & ENVIROMENTAL MANUAL PROCEDURE: S560 Radiation Safety REV /14/2012

2008 ASHP Summer Meeting Seattle, Washington Educational Session Abstracts

Instructions for Use Reprocessed Arthroscopic Shavers

PDA Points to Consider relating to EU GMP Annex 1 changes. Presented by Ashley Isbel 30 November, 2016

AMENDATORY SECTION (Amending WSR , filed 10/10/95, effective 11/10/95)

How Do You Know If Your Sterilized Instruments Remain Sterile?

USP 800 and Hazardous Medications

If viewing a printed copy of this policy, please note it could be expired. Got to to view current policies.

Energy-Efficient Biological Safety Cabinet Reduces Energy Costs While Ensuring Safety

SurgiCube Clinical Tests

MANUFACTURING OPERATING STANDARDS AND RESTRICTIONS FOR COMMERCIAL CANNABIS OPERATIONS IN CITY OF CARSON

Injection Safety. Alana Cilwick, MPH. Injection Safety Coordinator

City of Carson 701 E. Carson St., Carson, CA Telephone: (310) ; ci.carson.ca.us

Legal Aspects in Intravenous Nutrient Therapy. Nayan Patel PharmD

Hieber's Pharmacy 12/5/17

Procedure for Blood Analysis. 1.0 Purpose - This procedure specifies the methods for performing blood analysis in forensic casework.

Increased Microbiological Challenge Test with Bunsen Burner Inside the Cabinet

Model Standards for Pharmacy Compounding of Non-Sterile Preparations

Humidity Measurement in H 2 O 2 Bio-Decontamination

1.40 Prevention of Nosocomial Pneumonia

ASTM Workshop on Medical Device Cleanliness

MAKE THE CLEAR CHOICE. IV Products and Accessories Designed to Help Maximize Clinical Performance While Optimizing Savings

Procedure for Blood Analysis. 1.0 Purpose - This procedure specifies the methods for performing blood analysis in forensic casework.

Product Sterility Testing... To Test or Not to Test? That Is the Question


Aseptic Process Simulation (APS) Program Risk Assessment

Sterilization of health care products Radiation. Part 2: Establishing the sterilization dose

ZINEDENT PRODUCTS WARRANTY

Policy Guide Injectable Hydromorphone Maintenance Treatment (2018)

Biosafety Level 3 (BL3)

Cleanroom vs. Isolator Concept Performance and cost comparison. Guy Turner, General Manager Bioquell Asia Pacific

The American Society of Diagnostic and Interventional Nephrology. Application for Recertification. Hemodialysis Vascular Access Procedures

Wipe Kit. For addressing <USP 800> Hazardous Drugs - Handling in Healthcare Settings

Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric aspects

Complex Medical Devices and Steam Sterilization. By Andrew Gay Director - Sterilizer Validation Australia

Approval Signature: Original signed by B. Postl. June 2007

PinPrick Stimulator Set

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

DOELAP On-Site Assessment Requirements Checklist Page 1 of 24 Participant:

Allergy Vial Preparations and USP 797. Donald W Aaronson MD JD MPH

Dear Valued Customer,

Mammography Quality Control: A Refresher

STERI-PEROX. Technical Data File. 3% & 6% Hydrogen Peroxide Solution VL Rev. 20 January 2012

Device Preparation (all steps to be performed per standard interventional technique)

TECHNICAL BULLETIN GENERAL INFORMATION

8 Performing Medical Procedures

AMENDATORY SECTION (Amending WSR , filed 10/10/95, effective. WAC Purpose. The purpose of WAC through

micropipettes clinical laboratory single channel fully autoclavable

Carcinogens STANDARD OPERATING PROCEDURE (SOP) Click here to enter a date. REQUIRED - Insert Preparer's Name CLSC SOP Task Force

Environmental Monitoring How to Satisfy the Regulator. Presented by Tanja Varglien, July 2017

MUGA Scan. A Patient s Guide. Copyrighted Material. HeartWise Patient Education

FROM GAMETES TO BLASTOCYSTS. Simpler Processes, Less Stress, Better Results.

Hearing Conservation Program Table of Contents

Sterile U Network. Quality Control for Table-top Steam Sterilizers. Introduction: T U T O R I A L S

If viewing a printed copy of this policy, please note it could be expired. Got to to view current policies.

Chapter 9 TOBACCO AND SYNTHETIC NICOTINE CONTROL

Dr FuelCell Load Measurement Box

EU Regulatory Update & GMP Deficiencies. Bryan J Wright July 2017

Biosafety Level 2 Standard Practices and Containment Office of Research Safety Affairs

CDC s Position Protect Patients Against Preventable Harm from Improper Use of Single-dose/Single-use Vials

Draft Guidance for Industry and FDA Staff

Validation Introduction. Presented by John Montalto 27 March, 2013

Receiver and App Setup

PUPSIT. Micheal Schafferius Application Specialist

Script for Podcast on Injection Safety

Dental Extraoral X-ray Systems

STANDARDS FOR PHARMACY COMPOUNDING OF NON-STERILE PREPARATIONS

Dental Intraoral X-ray Systems

COMMENTS. Submitted by The International Pharmaceutical Aerosol Consortium

1. Introduction. 2. API 5.7 Testing Protocol for Differential Pressure Flow Measurement Devices

Town and Country Compounding and Consultation Services, LLC 10/17/17

Laboratory Orientation and Safety

Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

Chapter 5: Checking and Maintaining Ultrasound Equipment

Environmental Health & Safety Policy Manual

Guidelines for the Qualification and Certification of Penetrant Testing Personnel

OFFICE ERGONOMICS SELF-ASSESSMENT

ST79:2006 Section 10: Quality Control Key Changes

Eyewash and Safety Showers HM 20 Page 1

Laboratory Ventilation Policy

Faculty of Social Science Department of Applied Disability Studies ADST 5P76 SUPERVISED PRACTICUM IN APPLIED BEHAVIOUR ANALYSIS

Department of Surgery

Transcription:

Unidirectional Airflow Smoke Test Protocol Persons signing as approvers shall have examined the Unidirectional Airflow Protocol. This approval shall signify that testing of operational parameters is adequate to demonstrate that the system meets unidirectional airflow for isolator s requirements. APPROVALS Name/Title Signature Date Name/Title Signature Date Name/Title Signature Date Protocol prepared by: Name Signature Dept./Organization: Phone: Page 1

Unidirectional Airflow Smoke Test Protocol TABLE OF CONTENTS SECTION NO. CONTENTS 1.0 SIGNATURE LOG 1 TABLE OF CONTENTS FDA GUIDANCE 2 SIGNATURE LOG 3 2.0 PROTOCOL OBJECTIVE 4 3.0 RESPONSIBILITIES 5 4.0 TEST DEVICES 5 5.0 TEST PERFORMED 6 6.0 SPECIFICATIONS AND ACCEPTANCE CRITERIA 6 SMOKE TEST RESULTS 7 List of attachments Included on computer stick Unidirectional airflow smoke test protocol Directional airflow vector sketch Video of onsite smoke test Acceptance criteria FDA validation including smoke test PAGE NO. FDA guidance (USP <797> references FDA definition of unidirectional airflow) In situ air pattern analysis should be conducted at the critical area to demonstrate unidirectional airflow and sweeping action over and away from the product under dynamic conditions. The studies should be well documented with written conclusions, and include evaluation of the impact of aseptic manipulations (e.g., interventions) and equipment design. Videotape or other recording mechanisms have been found to be useful aides in assessing airflow initially as well as facilitating evaluation of subsequent equipment configuration changes. Page 2

Unidirectional Airflow Smoke Test Protocol 1.0 SIGNATURE LOG Persons performing any test or portions of a test, reviewing data, or entering comments on a test page will enter their printed name, their signature, Company and their initials. Name (Print) & Company Signature Initial/Date Name (Print) & Company Signature Initial/Date Location Serial Number Single Dual Other Page 3

2.0 Protocol Objective The objective of this unidirectional airflow smoke testing protocol is to verify that the isolator air handling system provides unidirectional air flow during dynamic compounding conditions in the critical pressing area per FDA and USP <797> definitions. The MIC isolator is designed for the protection of components during the aseptic manipulation based on USP <797> that states The objective of this chapter is to describe conditions and practices to prevent harm, including death, to patients that could result from (1) microbial contamination (nonsterility), (2) excessive bacterial endotoxins.. The two elements play a role in creating the aseptic environment are decontamination of components used to produce compounded preparations and providing an ISO class 5 air particulate quality environment in which manipulations occurs. The smoke test protocol does not address decontamination directly however airflow does play a role in the effectiveness of the decontamination process in terms of exposure and residence time on surfaces of non-sterile outside of components in the environment used in compounding. The MIC airflow design is to enhance the decontamination process as well as meet the definitions of air quality required in the Direct Compounding Area (DCA) described as a critical area within the ISO Class 5 primary engineering control (PEC) where critical sites are exposed to unidirectional HEPA-filtered air. Since particulates are generated during the aseptic manipulations from both component surfaces as well the actual manipulations it is important that these particles be removed from the (DCA). Unidirectional airflow is a means of controlling and removing particulate. FDA guidance and USP <797> use the same definition of unidirectional airflow i.e. Unidirectional flow- An airflow moving in a single direction, in a robust and uniform manner, and at sufficient speed to reproducibly sweep particles away from the critical processing or testing area. Particulate control and removal is important in all aseptic isolators. Controlling direction is part of airflow control. There are several methods of determination of direction of airflow with smoke testing being the most subjective. Smoke testing is used as an indicator of the direction of the airflow depends on personnel observation. Individual observation are influenced by location, density of smoke and type of materials used to generate the smoke. Experience has shown that a properly located video camera ideally not a cell phone inside the isolator produces the most realistic view of a smoke pattern. Filming is an art, get somebody with expertise. Be aware of B.R.A.D 1 : Background, Reflection, Angle and Direction Page 4

1.Juan M. Rodríguez,Validation Manager,Bristol-Myers Squibb, Syracuse, NY 3.0 Responsibilities Isolator Manufacturer - Identify intended Direct Compounding Area (DCA). MIC chamber from each side panel and three inches from front and back end panels - Identify placement of smoke 1 source - Identify correct placement for camera Owner Verify that the individual conducting the smoke test has the following: - The correct protocol for conducting the test - Familiar with protocol positing requirements of both smoke source and camera - Reviewed validated smoke test video - Confirm certifier has previous experience with horizontal air flow. If not request they contact CTG. - Verify materials for conducting the dynamic test are available Certifier Review the correct protocol for conducting the smoke test including placement of smoke source (9 inches from left end panel, 9 inches off the floor and 9 inches from front panel) and camera. Remember B.R.A.D 1. - Review video to become familiar with required equipment - Review protocol and verify correct equipment is available - Review placement requirements for smoke source, camera 4.0 Testing Devices All devices used in testing will be documented, and calibrated where appropriate. Information recorded is to include manufacturer, model number and date of calibration or calibration expiration date. Item Manufacturer Model Number Date of Calibration / Expiration Date Other Initials Page 5

5.0 Tests Performed 5.1 Particle Counts Particle counts will be taken in the DCA. Location 1 2 3 Initials Counts 5.2 Smoke Source 5.2.1 Verify the smoke source is in the correct position 5.2.2 Verify smoke source is able to generate a consistent and repeatable source of visible smoke that is 5.2.3 Verify that the smoke source does not generate an excessive amount of smoke that will impact the clarity of the video. 5.2.4 Verify material used to generate smoke Note Titanium tetrachloride effects stainless steel and can deactivate hydrogen peroxide used to reduce bioburden 5.3 Camera 5.3.1 Verify camera position (Background, Reflection, Angle and Direction) 5.3.2 Verify the area filmed encompasses the DCA 6.0 Specifications and Acceptance Criteria 6.1 Airflow is unidirectional per FDA definition - An airflow moving in a single direction, in a robust and uniform manner, and at sufficient speed to reproducibly sweep particles away from the critical processing or testing area. Acceptance Criteria Airflow is consistent with FDA definition of unidirectional airflow 6.1.1 The DCA for the MIC chamber from each side panel and three inches from front and back end panels Acceptance Criteria testing conducted within DCA 6.2 Verify ISO 5 conditions inside the DCA via particle counts. Sweeping action over and away from the product under dynamic conditions Acceptance Criteria Particle count do not exceed ISO class 5 Page 6

Unidirectional Airflow Smoke Test Protocol Results Summary Acceptance Criteria 6.1 Airflow is unidirectional per FDA definition - An airflow moving in a single direction, in a robust and uniform manner, and at sufficient speed to reproducibly sweep particles away from the critical processing or testing area. Acceptable Yes or No 6.1.1 Smoke test observations were of flow within the DCA 6.2 Verify ISO 5 conditions inside the DCA via particle counts. Reviewed by: Date: Persons signing as reviewers of individual test pages have determined that the results are acceptable or that no further action is necessary on a given test, and that the test form has been properly completed. Page 7