Case Report Endovascular Treatment for Pseudoaneurysms after Surgical Correction of Aortic Coarctation

Similar documents
Case Report Successful Implantation of a Coronary Stent Graft in a Peripheral Vessel

Peter I. Kalmar, 1 Peter Oberwalder, 2 Peter Schedlbauer, 1 Jürgen Steiner, 1 and Rupert H. Portugaller Introduction. 2.

Department of Internal Medicine, Saitama Citizens Medical Center, Saitama , Japan

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Case Report Late Type 3b Endoleak with an Endurant Endograft

Case Report Coronary Artery Perforation and Regrowth of a Side Branch Occluded by a Polytetrafluoroethylene-Covered Stent Implantation

Abdominal and thoracic aneurysm repair

Tom Eisele, Benedikt M. Muenz, and Grigorios Korosoglou. Department of Cardiology & Vascular Medicine, GRN Hospital Weinheim, Weinheim, Germany

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Subclavian artery Stenting

Subclavian Artery Plug Embolization (SAPE study): a real experience about endovascular subclavian occlusion prior to thoracic vascular repair

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Case Report Asymptomatic Pulmonary Vein Stenosis: Hemodynamic Adaptation and Successful Ablation

Reimbursement Guide Zenith Fenestrated AAA Endovascular Graft

Research Article Abdominal Aortic Aneurysms and Coronary Artery Disease in a Small Country with High Cardiovascular Burden

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

SCAI Fall Fellows Course Subclavian/Innominate Case Presentation

Talent Abdominal Stent Graft

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Case Report Endovascular Repair of a Large Profunda Femoris Artery Pseudoaneurysm

Development of a Branched LSA Endograft & Ascending Aorta Endograft

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Case Report Stent Graft-in-Stent Graft as a Rescue Technique for Endovascular Treatment of Giant Extracranial Internal Carotid Aneurysm

Case Report A Rare Case of Complete Stent Fracture, Coronary Arterial Transection, and Pseudoaneurysm Formation Induced by Repeated Stenting

Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique

Acute dissections of the descending thoracic aorta (Debakey

Thoracic Endovascular Aortic Repair (TEVAR) Indications and Basic Procedure

Endovascular aortic stent grafts have forever

Percutaneous Approaches to Aortic Disease in 2018

Endovascular Treatment of Type II Endoleak Following TEVAR for Thoracic Aortic Aneurysm: Squeeze Technique to Reach the Aneurysmal Sac

Access More Patients. Customize Each Seal.

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type 1b Endoleak following an EVAR for Ruptured AAA

A New EVAR Device for Infrarenal AAAs

CUSTOM-MADE SCALLOPED THORACIC ENDOGRAFTS IN DIFFERENT HOSTILE AORTIC ANATOMIES

P Paraplegia abdominal aortic aneurysm repair, 52 paraparesis, 52 pathophysiology, 51 rates and endografts, 51 two-stage approach, 129

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

Case Report Tortuous Common Carotid Artery: A Report of Four Cases Observed in Cadaveric Dissections

Case Report Surgical Treatment for Profunda Femoris Artery Aneurysms: Five Case Reports

Ancillary Components with Z-Trak Introduction System

Use of covered stents and endograft as a rescue treatment in a patient with a complex form of recurrent aortic coarctation

Technique and Outcome of Laser Fenestration For Arch Vessels

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

SAMPLE EDITION PELVIC AND LOWER EXTREMITY ARTERIES WITH ENDOVASCULAR REVASCULARIZATION. Cardiovascular Illustrations and Guidelines

IMAGES. in PAEDIATRIC CARDIOLOGY

Endoanchor-assisted TEVAR

Ascending Thoracic Aorta: Postsurgical CT Evaluation

Percutaneous Intervention for totally Occluded Coarctation Of Aorta. John Jose, Vipin Kumar, Ommen K George Dept Of Cardiology

Nellix Endovascular System: Clinical Outcomes and Device Overview

Modified candy-plug technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

My personal experience with INCRAFT in standard and challenging cases

Experience of endovascular procedures on abdominal and thoracic aorta in CA region

HOW SHOULD WE FOLLOW PATIENTS AFTER AORTIC ARCH INTERVENTIONS?

Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

Indications for use. Contraindications within the United States

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Neurological Complications of TEVAR. Frank J Criado, MD. Union Memorial-MedStar Health Baltimore, MD USA

Objective assessment of current stent grafts: which graft for which lesion. Ludovic Canaud, MD, PhD Pierre Alric, MD, PhD Montpellier, France

Access (Antegrade, Retrograde, Pedal)

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

ENDOVASCULAR REPAIR OF COMPLEX EXTRA-CRANIAL SUPRA-AORTIC ANEURYSMS

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

How to Determine Tolerance for Branch Vessel Coverage

Management of Endoleaks. Michael Meuse, M.D Vascular and Interventional Radiology 12/14/09

Santi Trimarchi, MD, PhD Vascular Surgeon Thoracic Aortic Research Center, Director IRCCS Policlinico San Donato University of Milan

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study,

Repair of Intracranial Vessel Perforation with Onyx-18 Using an Exovascular Retreating Catheter Technique

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Introduction 3. What is Peripheral Vascular Disease? 5. What Are Some of the Symptoms of Peripheral Vascular Disease? 6

Abdominal Aortic Aneurysm 가천대길병원 이상준

Introduction What Causes Peripheral Vascular Disease? How Do Doctors Treat Peripheral Vascular Disease?... 9

Hybrid Repair of a Complex Thoracoabdominal Aortic Aneurysm

Corporate Medical Policy

Durable outcomes. Proven performance.

Left subclavian artery (LSA) coverage during

CAROTID ARTERY STENTING TECHNICALS ASPECTS. Symposium Abbott Vascular CANNES MEET 2008 Drs V PIRET, P BERGERON

Hybrid procedure to treat aortic arch aneurysm combined with aortic arch coarctation and left internal carotid artery aneurysm (Case Report)

Technique and Tips for Complicated AAA Cases with Stent Graft

Diagnosis and Management of Femoral Access Site Complications IV: Novel Techniques for Endovascular Rescue

account for 10% to 15% of all traffic fatalities majority fatal at the scene 50% who survive the initial injury die in the first 24 hours 90% die

CAROTID ARTERY ANGIOPLASTY

Overview of Subclavian & Innominate Artery Interventions

Prevention and Management of Vascular Complications Related to Transcatheter Aortic Valve Implantation

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR

How to achieve a successful proximal sealing in TEVAR? Pr L Canaud

EVAR replaced standard repair in most cases. Why?

Ozge Korkmaz, 1 Osman Beton, 2 Sabahattin Goksel, 1 HakkJ Kaya, 2 and Ocal Berkan Introduction. 2. Case Report

Primary to non-coronary IVUS

Review Report. Instrument & Apparatus 7 Organ function replacement device. GORE TAG Thoracic Aortic Stent Graft System

Introducing the GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System

Management of Acute Aortic Syndromes. M. Grabenwoger, MD Dept. of Cardiovascular Surgery Hospital Hietzing, Vienna, Austria

Transcription:

SAGE-Hindawi Access to Research Volume 2011, Article ID 649207, 4 pages doi:10.4061/2011/649207 Case Report Endovascular Treatment for Pseudoaneurysms after Surgical Correction of Aortic Coarctation M. Rabellino, 1, 2 T. Zander, 1 G. González, 1 S. Baldi, 1 H. Cheves, 3 A. Estigarribia, 3 R. Llorens, 3 J. M. Carreira, 1 and M. Maynar 1 1 Department of Interventional Radiology, Hospital Hospiten Rambla, General Franco 115, 38001 Santa Cruz de Tenerife, Spain 2 Department of Endovascular Therapy, Hospital Hospiten Rambla, General Franco 115, 38001 Santa Cruz de Tenerife, Spain 3 Department of Cardiovascular Surgery, Hospital Hospiten Rambla, General Franco 115, 38001 Santa Cruz de Tenerife, Spain Correspondence should be addressed to M. Rabellino, jmrabellino@hotmail.com Received 17 November 2010; Accepted 9 February 2011 Academic Editor: Christian W. Hamm Copyright 2011 M. Rabellino et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Late complications after surgical repair of aortic coarctation are not uncommon. Among these complications pseudoaneurysms are the most frequent complications, occurring between 3 and 38%. Reoperation in these patients is associated with high morbidity and mortality. In the last decade, endovascular techniques emerged as an alternative to conventional surgery with excellent results. We report the case of two patients who presented with pseudoaneurysms after surgical correction for aortic coarctation, which were treated by endovascular means. 1. Introduction Open surgery remains the gold standard for the treatment of aortic coarctation. Surgical treatment includes resection of the narrow segment with end-to-end anastomosis of the aorta and aortoplasty using a subclavian flap or synthetic material. These techniques show initially excellent results; however, late anastomotic pseudoaneurysms develop in 3 to 38% of all cases [1, 2]. Reoperation in these patients is complex and associated with high morbidity and mortality [2 5]. Therefore, in the last decade endovascular techniques emerged to treat these complications [5 9], based on the experience of endovascular treatment in atherosclerotic aneurysms in this location. We report the case of two patients with pseudoaneurysms after previous surgical repair which were treated by endovascular means. 2. Case 1 A 31-year-old female patient underwent surgical correction of aortic coarctation at the age of 4 years using a Goretex patch. During a routine angio-ct 17 years after the initial surgery, a recoarctation and a pseudoaneurysm were diagnosed, and a balloon-expandable stent was placed at the recoarctation site. A control angio-ct showed stent migration and growth of the pseudoaneurysm measuring 53 40 mm in diameter. In contrast to the previous angio- CT, the pseudoaneurysm was multilobulated with irregular walls, and the origin of the left subclavian artery was dilated with 25 mm in diameter. Due to the morphologic changes and the size of the pseudoaneurysm, this patient was referred to our institution for endovascular treatment. Before treatment, a diagnostic angiography was performed using a 5F pigtail catheter with markers. The angiography showed a small caliber aortic arch with severe angulation and a pseudoaneurysm, that extended proximally to the origin of the left subclavian artery. The balloon-expandable stent was in contact with the aortic wall only at its distal end (Figure 1). Treatment was performed in two times. Under general anesthesia a left carotid-subclavian bypass was performed using prosthetic Goretex of 8 mm, and the left subclavian artery was ligated. Two days after the surgery, the endovascular treatment was performed under general anesthesia and systemic heparinization. A right femoral access was used to introduce a Captivia (Medtronic Vascular, Santa Rosa, CA) thoracic endoprosthesis, 22 150 mm. The device was released covering the origin of the left subclavian artery (Figure 1). Seventy-two hours after the

2 Figure 1: Aortic angiography showing an angulated aortic arch and a small caliber thoracic aorta. A lobulated aortic pseudoaneurysm extends proximally to the left subclavian artery, and a large caliber balloon-expandable stent is adhered to the aortic wall at its distal end. Final result after completion of the carotid subclavian bypass and exclusion of the pseudoaneurysm. A heparin-related leak can be found which extends to the left subclavian artery. and Angio-CT images showing exclusion of the pseudoaneurysm without evidence of leakage. endovascular treatment, the patient was discharged. No complication was found in the angio-ct (Figures 1 and 1). After 3 months the patient was asymptomatic without evidence of pathologic images in the control angio-ct. 3. Case 2 A 46-years-old male patient, who presented with mild hemoptysis at our institution, was operated at the age of 17 years for aortic coarctation using a prosthetic patch. In the angio-ct a pseudoaneurysm was diagnosed as a late complication of surgery of aortic coarctation measuring 64 68 mm in diameter. The diagnostic angiogram showed a saccular and irregular shaped pseudoaneurysm (Figure 2). The right vertebral artery was found to be patent without atherosclerotic lesions and of preserved diameter. An aortobronchial fistula could be identified neither in the angio-ct nor in the diagnostic angiogram. Under general anesthesia and systemic heparinization the right common femoral artery was dissected, and a first endoprosthesis body Zenith TX2 (Cook Inc, Bloomington, IN) 22 115 mm was introduced and released, covering the left subclavian artery. After that, a second endoprosthesis body Captivia (Medtronic Vascular, Santa Rosa, CA) 26-26-150 mm was used to exclude the pseudoaneurysm. Due to the risk of death caused by severe hemoptysis, an emergency treatment was considered, consisting in endovascular bridging with stent grafts and proximal occlusion of the left subclavian artery. For this reason, two different endoprosthesis were used, since no other stent grafts, available in our stock, met the required characteristics. After liberating both devices a latex balloon was introduced over a stiff wire for sealing. Through a left brachial access the left subclavian artery was than embolized using a 16-mm Amplatzer device. The final angiogram showed no leaks with present collateral flow in the left subclavian artery (Figures 2 and 2) via right vertebral artery. The control angio-ct 3 days after the surgery showed a leak. There was an uncertainty, whether there was a leak type I or II, additionally a pseudoaneurysm in the right subclavian artery was found which was considered iatrogenic after placement of a jugular central line. Through a right brachial access the pseudoaneurysm was embolized with 3 microcoils (Trufill, Cordis, Miami Lakes, FL.) (Figures 3 and 3). The same access was used to clearly demonstrate a leak type I of the first endoprosthesis body (Figure 3). Under general anesthesia a 23-mm angioplasty balloon catheter was delivered through a left femoral artery access to successfully seal the leak. Before discharging the patient, a control angio-ct was performed, and no leak could be identified. At the 6month follow-up the patient remained asymptomatic without hemoptysis and without other evidence of leakage or pathologic images in the angio-ct. 4. Discussion Among the surgical techniques for the treatment of aortic coarctation, the surgical resection and end-to-end anastomosis has demonstrated low complication rates; however, late complications are still common [1, 2]. Late pseudoaneurysms should not be left untreated, as rupture has been

3 Figure 2: Angiography shows a large aortic pseudoaneurysm extending to the origin of the left subclavian artery with an irregular wall (white circle). Final angiography after stent placement and embolization of the left subclavian artery demonstrates complete exclusion of the pseudoaneurysm with no evidence of leakage. and Late angiographic image shows left subclavian artery perfusion due to subclavian steal. (e) Figure 3: Selective angiography of the left subclavian artery showing iatrogenic pseudoaneurysm after central line placement. Selective intraaneurismal angiography was performed with a 1.9 Fr microcatheter showing a long neck. Result after embolization with microcoils demonstrating complete occlusion of the sack. Selective angiography using a 5 Fr Sidewinder catheter shows a type I leak which can also be found on the angio-ct. (e) After angioplasty of the proximal endoprosthesis body the type I endoleak could be sealed completely. described even in small pseudoaneurysms [7]. Knyshov et al. reported a rupture rate at 15 years of 100% of these pseudoaneurysms [2]. Reoperation in these patients is complex and is associated with high mortality and morbidity such as paraplegia, recurrent nerve paralysis, and bleeding [2]. In the last decade, endovascular techniques were introduced for the treatment of late complications after coarctation surgery in order to reduce complications related to open surgery. Even if the reported series are small, they show very encouraging results [5 9]. The technical difficulty of treating these patients includes hypoplastic aortic arch, proximal fixation zone in relation to the extension of the pseudoaneurysm and the dimension of the access arteries. None of our patients had aortic arch hyperplasia; however one case presented with a severe angulated arch and a small diameter aorta. Additionally, the procedure was complicated by an aortic stent which was attached to the arterial wall only by the distal end. In this kind of patient and in patients with small caliber accessing arteries, friction and resistance can complicate the procedure, not permitting the device to be delivered to the proximal anchoring zone. The use of new devices with hydrophilic coating could help to overcome problems with angled arches, intravascular devices, and small accessing arteries.

4 In both cases the left subclavian artery had to be covered. In the first case, the left subclavian artery was revascularized through a carotid-subclavian bypass, and in the second case the subclavian artery was embolized using an Amplatzer device. Left subclavian artery occlusion is generally well tolerated; however there are several studies reporting the risk of complications such as superior extremity claudication or associated neurological symptoms [10 13]. Preinterventional angiography of the supraaortic vessels should be performed in order to demonstrate collateralization blood flow from the right to the left vertebral artery. These studies have been conducted on a patient population with atherosclerotic disease in which the collateral pathway, like vertebral arteries or the thyrocervical trunk, may be affected by the arteriosclerotic angiopathy. However, young patients usually do not have atherosclerotic disease, therefore occlusion of the left subclavian artery might be better tolerated. In a previous publication we reported the case of a young patient with traumatic aortic rupture in whom the left vertebral artery originated directly from the aortic arch [14]. In this case, despite independent embolization of left vertebral artery and left subclavian artery due to a type II leak, no neurological symptoms or signs of claudication in the left upper limb could be found, and the ipsilateral brachial and radial pulse was palpable in the following controls [14]. Although there are reports of endovascular treatment in late complications after surgical repair of aortic coarctation, these reports include a small number of patients. The published results are very encouraging, and with new devices more patients with complex anatomy can be treated safely with a high technical success. The endovascular treatment is an important alternative to surgical reoperation due to its lower morbidity and mortality. However, more data from long-term monitoring are needed to determine their effectiveness and to detect late complications. [5] H. Ince, M. Petzsch, T. Rehders et al., Percutaneous endovascular repair of aneurysm after previous coarctation surgery, Circulation, vol. 108, no. 24, pp. 2967 2970, 2003. [6] B. Marcheix, Y. Lamarche, P. Perrault et al., Endovascular management of pseudo-aneurysms after previous surgical repair of congenital aortic coarctation, European Cardio-Thoracic Surgery, vol. 31, no. 6, pp. 1004 1007, 2007. [7] S. Kutty, R. K. Greenberg, S. Fletcher, L. G. Svensson, and L. A. Latson, Endovascular stent grafts for large thoracic aneurysms after coarctation repair, Annals of Thoracic Surgery, vol. 85, no. 4, pp. 1332 1338, 2008. [8] L. Botta, V. Russo, G. Oppido et al., Role of endovascular repair in the management of late pseudo-aneurysms following open surgery for aortic coarctation, European Cardio-Thoracic Surgery, vol. 36, no. 4, pp. 670 674, 2009. [9] M. Midulla, A. Dehaene, F. Godart et al., TEVAR in patients with late complications of aortic coarctation repair, Endovascular Therapy, vol. 15, no. 5, pp. 552 557, 2008. [10] O. Galili, S. Fajer, A. Eyal, and R. Karmeli, Left subclavian artery occlusion by thoracic aortic stent graft: long-term clinical and duplex follow-up, Israel Medical Association Journal, vol. 9, no. 9, pp. 668 670, 2007. [11] T. C. Rehders, M. Petzsch, H. Ince et al., Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: risk and relevance, Endovascular Therapy, vol. 11, no. 6, pp. 659 666, 2004. [12] P. J. Riesenman, M. A. Farber, R. R. Mendes, W. A. Marston, J. J. Fulton, and B. A. Keagy, Coverage of the left subclavian artery during thoracic endovascular aortic repair, Vascular Surgery, vol. 45, no. 1, pp. 90 95, 2007. [13] J. Görich, Y. Asquan, H. Seifarth et al., Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs, Endovascular Therapy, vol. 9, no. 2, pp. II39 II43, 2002. [14] M. Rabellino, L. García Nielsen, S. Baldi et al., Retrograde embolization of the left vertebral artery in a type II endoleak after endovascular treatment of aortic thoracic rupture: technical note, CardioVascular and Interventional Radiology, vol. 32, no. 1, pp. 169 173, 2009. Conflict of Interests The authors declare that they have no conflict of interests. References [1] Y. von Kodolitsch, M. A. Aydin, D. H. Koschyk et al., Predictors of aneurysmal formation after surgical correction of aortic coarctation, the American College of Cardiology, vol. 39, no. 4, pp. 617 624, 2002. [2] G.V.Knyshov,L.L.Sitar,M.D.Glagola,andM.Y.Atamanyuk, Aortic aneurysms at the site of the repair of coarctation of the aorta: a review of 48 patients, Annals of Thoracic Surgery, vol. 61, no. 3, pp. 935 939, 1996. [3]M.Cohen,V.Fuster,P.M.Steele,D.Driscoll,andD.C. McGoon, Coarctation of the aorta: long-term follow-up and prediction of outcome after surgical correction, Circulation, vol. 80, no. 4, pp. 840 845, 1989. [4] K. Ala-Kulju and L. Heikkinen, Aneurysms after patch graft aortoplasty for coarctation of the aorta: long-term results of surgical management, Annals of Thoracic Surgery, vol. 47, no. 6, pp. 853 856, 1989.

MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity