Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride

Similar documents
INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION

Assessment of nickel titanium and beta titanium corrosion resistance behavior in fluoride and chloride environments

Effect of Fluoride on Nickel-Titanium and Stainless Steel. Orthodontic Archwires: An In-Vitro Study

Titanium (Ti) is the most widespread

Faculty of Dentistry, National Yang-Ming University, Taipei, Taiwan, ROC.

ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE IN PHYSIOLOGICAL MEDIA OF NITINOL WIRE USED AS BIOIMPLANT

Materials Science and Engineering C

INHIBITIVE EFFECT BY PSIDIUM GUAJAVA LEAF EXTRACT ON THE CORROSION OF Al-Si-Mg (SSM-HPDC) ALLOY IN SIMULATED SEAWATER ENVIRONMENT

Surface Protection of Niti- Shape Memory Alloy by Colgate Visible White Toothpaste

Department of Industrial Chemistry, Pukyong National University, Busan 48547, Republic of Korea

A NEW CONCEPT OF MANAGEMENT OF INTRACANAL SEPARATED INSTRUMENT BY ELECTROCHEMICAL DISSOLUTION: A REVIEW

Effects of three different mouthwashes on the surface characteristics of nickel-titanium and Stainless steel archwires in orthodontics

Chapter 5 Biofunctionalization of Metallic Materials: Creation of Biosis Abiosis Intelligent Interface

Assessing the corrosion behaviour of Nitinol for minimally-invasive device design

Effect of Topical Fluoride on Surface of Cast. Titanium and Nickel-Chromium: An In Vitro Study

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Electrochemical Properties of Suprastructures Galvanically Coupled to a Titanium Implant

Supporting Information. for. Cyclodextrin inhibits zinc corrosion by destabilizing point defect formation. in the oxide layer

Eosin as Corrosion Inhibitor for Carbon Steel in Well Water

Research on Green Compound Corrosion Inhibitors of Carbon Steel. in Natural Seawater

Effects of Aluminum and Silicon as Additive Materials for the Zinc Anode in Zn-Air Batteries

Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

Trisodium Citrate As An Effective Corrosion Inhibitor For Carbon Steel In Chloride Environment

Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys

An overview of the corrosion aspect of dental implants (titanium and its alloys)

Ternary inhibitor system containing phosphonate, molybdate and Zn 2+ in corrosion control of carbon steel

The Protection Performance of Polypyrrole Coating Doped with Different Counter Anions for the Corrosion of NiTi Alloy

Angiogenesis of Metal Ions by Components of Dental Gold-silver-palladium Alloys used by Dental Prosthetics in Vitro

Investigation of adding fluoroapatite nanoparticles on compressive strength and corrosion behaviour of dental amalgams

Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, , P. R.

1 PG & Research Department of Chemistry, G.T.N. Arts College, Dindigul, Tamilnadu, India

Ghita Ouaziz 1, 2 and Oumarou Savadogo Introduction

THE EFFECT OF ADDING TiO 2 NANOPARTICLES ON DENTAL AMALGAM PROPERTIES

Synergistic effect of NTMP, Zn 2+ and ascorbate in corrosion inhibition of carbon steel

INTRODUCTION. Ó 2008 Wiley Periodicals, Inc.

Research Article Topographic Effects of Four Different Beverages to Cu-Sn (Eta Prime) Phase Amalgam Surface: A Scanning Electron Microscopic Study

Presented by Sean Day, Stanley Gelin, Kristin O Connor, Chris Sullivan, and Brian Wilson

Materials Chemistry and Physics

Plants Polyphenols: An Alternative Source for Green Corrosion Inhibitor

Retrieval of Fractured Files Based on Electrochemical Dissolution

The effective parameters on the corrosion behavior of dental amalgam

Corrosion inhibition of carbon steel by adipic acid Zn 2+ system

Modification of the surface topography of titanium

Electrophysiology & Neurochemistry Sensor for Stroke Studies

SUPPLEMENTARY INFORMATION. Direct Observation of the Local Reaction Environment during the Electrochemical Reduction of CO 2

ON THE CYTOTOXICITY OF ORTHODONTIC ARCHES IN HUMAN FIBROBLAST CULTURES

Enhancement of Photovoltaic Performance in Dye-Sensitized Solar Cell by a co-sensitization with Metal-Free Indoline Organic Dyes.

Higher National Unit specification. General information for centres. Unit code: F1M6 34

Synergistic effect of Fructose and Zn 2+ in controlling corrosion of carbon steel

Tahereh Hosseinzadeh Nik 1, Tabassom Hooshmand 2*, Habibeh Farazdaghi 3, Arash Mehrabi 1 and Elham S Emadian Razavi 1

Technical Report Effect of Cola Acuminata and Camellia Sinensis Mixed Extracts on the Corrosion Inhibition of Mild Steel in 0.

Determination of glucose in human urine by cyclic voltammetry method using gold electrode

Mutual Influence of HEDP and SDS - Zn 2+ System on Corrosion Inhibition of Carbon Steel

Biocompatibility of Dental Materials

Effect of surface treatment with commercial primers on tensile bond strength of auto-polymerizing resin to magnetic stainless steel

Corrosion Resistanne of the [TiN/CrN]n Coatings Deposited on Steel AISI 4140

CHAPTER THREE: INDUSTRY OVERVIEW... 6 STRUCTURE AND HISTORY OF THE DENTAL INDUSTRY... 6 STRUCTURE AND HISTORY (CONTINUED)... 8

Is there any clinical evidence?

A Review on Dental Amalgam Corrosion and Its Consequences

CORTEC Corporation. For: Behzad Bavarian California State University, Northridge, USA December 20, 2018

ZnO as corrosion inhibitor for dissolution of zinc electrodeposited mild steel in varying HCl concentration

1 Rua Santa Adélia, 166, Bangu, Santo André SP, Brazil

Dental erosion: In vitro model of wine assessor s erosion

Alpha-Bio Tec. Quality Assurance (QA) department performs a routine Quality Assurance (QA) and Quality Control (QC) procedures.

Effect of turmeric tamarind solution on surface roughness of conventional glass ionomer cement

Corrosion Inhibition of Mild Steel in Sulphuric acid medium by Thio Urea Zn 2+ system

ANALYSIS OF EFFICIENCY OF DENTAL IMPLANT OSSEOINTE- GRATION CHARACTERIZED BY VARIOUS SURFACE TYPES.

RBM dental implants by CST Process Technical Release September 2012

THE EFFECT OF TOPICAL FLUORIDE AGENTS ON COATED NICKEL-TITANIUM ARCHWIRES. A THESIS IN Oral and Craniofacial Sciences

STUDY ON ENHANCEMENT OF OSSEOINTEGRATION OF THE BIO-ACTIVE TITANIUM IMPLANT BY LOW INTENSIVE ULTRASOUND WAVE

Surface Characterization of Titanium Based Dental Implants

Visualisation of the Cochlea Implant/Tissue Interface

FUNDAMENTAL CHARACTERIZATION OF THE DEVELOPED TITA- NIUM DENTAL IMPLANT STRUCTURES

Scanning electron microscope characterization of abrasion in human teeth

Corrosion inhibition and biocidal activity of a cationic surfactant

Seniors Oral Care

Fretting-corrosion of Orthodontic Arch-wire/bracket contacts in Saliva Environment

Introduction. Jeong-Hi Kim, Hyoung-Juhn Kim,Tae-HoonLim, and Ho-In Lee

Dr. Abhishek Bhattacharya, Dr. Sneha Vaidya, Dr. Anil K Tomer, Dr. Panna Mangat and Dr. Afnan Ajaz Raina

Growth and Characterizations of Electrochemically Deposited ZnO Thin Films

COMMUNITY WATER FLUORIDATION: MYTHS AND FACTS

Effect of Casein Phosphopeptide amorphous Calcium. and Calcium Sodium Phosphosilicate

EFFICACY OF FLUORIDE MOUTHRINSE CONTAINING TRICALCIUM PHOSPHATE ON PRIMARY ENAMEL LESIONS : A POLARIZED LIGHT MICROSCOPIC STUDY

Electrochemical Corrosion of STS304 Acupuncture Needles by Electrical Stimulation

TECHNICAL NOTE SURFACE PREPARATION GUIDE

BioCoat Featuring SmartCap Technology

Monday Morning Pearls of Practice by Bobby Baig

care NCDC-Cleanser

XPS surface analysis of human tooth samples with EnviroESCA

SOFT DRINKS & DENTAL HEALTH.

University of Groningen. Erosive enamel wear and the inhibiting effect of topical fluorides Vieira Carvalho, Ana Maria Ramires dos Santos

ElectrochemicalEvaluationoftheAntioxidantCapacityofMoroccanOliveKernel

Short Communication Effects of Anions in Electrodeposition Baths on Morphologies of Zinc Oxide Thin Films

Formation of optimal surface of dental implants by CST SLA Process

N REPORT DOCUMENTATION PAGE 1/30/2009-1/30/2011. Final 02/23/2011

FABRICATION OF POLYMERIC FILMS AND COATINGS ON NICKEL-TITANIUM SHAPE MEMORY ALLOY AND THEIR BIOMEDICAL APPLICATIONS

INVITRO CORROSION STUDIES ON NICKEL TITANIUM SUPER ELASTIC ALLOY IN SYNTHETIC URINE IN PRESENCE OF D- GLUCOSE

BIOACTIVE BASICS. Bioactive materials elicit a controlled action and reaction in the physiological environment.

Synergistic effect of wire bending and salivary ph on surface properties and mechanical properties of orthodontic stainless steel archwires

Transcription:

Leonardo Journal of Sciences ISSN 1583-0233 Issue 11, July-December 2007 p. 33-40 Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride Latifa KINANI and Abdelilah CHTAINI* Equipe d Electrochimie Moléculaire et Matériaux Inorganiques, Maroc chtainia@yahoo.fr ( * Corresponding authors) Abstract The objective of this study was to demonstrate the effect of eugenol on the titanium corrosion in artificial saliva enriched with eugenol at different concentration. The corrosion behaviour and titanium surface characterization were investigated by electrochemical measurements and SEM. Keywords Corrosion; Titanium; Fluoride; ph; Eugenol; SEM Introduction Titanium and its alloys are widely used in dentistry as prosthetic appliances because of a high corrosion resistance and good biocompatibility. These valuable properties are caused by passive films that are rapidly formed in the body fluid environment [1-3]. Recently, mouth-rinses, toothpastes, and prophylactic agents containing fluoride are utilizing to prevent the dental caries. However, decreasing the corrosion resistance of titanium in solutions containing fluoride has been reported [4-12]. The corrosion behaviours are related to the concentration of fluoride and the surrounding environment Therefore, the surface reaction on titanium under the existence of fluoride is important to understand the corrosion and tarnish of titanium in oral environment. Recently the corrosion of titanium was suppressed in solutions containing fluoride and eugenol (Figure1). http://ljs.academicdirect.org 33

Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride Latifa KINANI and Abdelilah CHTAINI Eugenol occurs widely as a component of essential oils and is a major constituent of clove oil. It has been used since at least the nineteenth century, primarily as a flavouring agent, in a variety of foods and pharmaceutical products, and as an analgesic in dental materials. Recently it has been used as inhibitor on the corrosion of stainless steel in phosphoric acid solution [13]. OH OCH 3 Figure 1. Chemical formula of eugenol Materials and Methods The specimens used were plats (1cm 1cm 1mm) placed in different medium, adaptable to the working electrode. The samples were mechanically cleaned with abrasive strips. The electrolyte reference used was Fusayama Meyer artificial saliva. The composition of this solution, which closely resembles natural saliva, is KCl (0.4 g/l), NaCl (0.4 g/l), CaCl 2. 2H 2 O (0.906 g/l), NaH 2 PO 4, 2H 2 O (0.690 g/l), Na 2 S, 9H 2 O (0.005 g/l), Urea (1 g/l). The ph was measured with an XC type glass electrode. The ph (7.03) of this reference saliva corresponding to our first test medium. The second medium used had the same contents as the first, but the ph was lowered by adding lactic acid. This acid was chosen in order to obtain conditions that were as close as possible to the clinical reality. The third medium was identical to the reference medium but was enriched with fluoride ions with a concentration of 0.1% and the last medium is containing fluoride at ph = 2 at different concentration of eugenol. For electrochemical step, we used a glass electrochemical cell, with the thermostat set at 37 ± 0.1 C. The three electrodes system was used, with a saturated calomel electrode, platinum plat (1cm 1cm) counter electrode and working electrode (specimens test) 34

Leonardo Journal of Sciences ISSN 1583-0233 Issue 11, July-December 2007 p. 33-40 connected to a Voltalab 10 type computer controlled potentiostat. The electrochemical analysis involved, measuring of linear polarization resistance (R p ), potentiodynamic polarization and AC impedance in different media. The surfaces of the specimens were observed on scanning electron microscopy. Statistical analyses The corrosion parameters, including I corr and R p, were statistically analyzed using one - way ANOVA for analyzing the factor of NaF or eugenol concentration in 0.1% NaF containing medium. The test of Tukey s test (α = 0.05) was chosen as the following multiple comparison technique when necessary. The results of two-way ANOVA for Rp values and I corr proved that fluoride, and the concentration of the eugenol in presence of fluoride had a statistically significant influence on the value of R p (p < 0.00002) and I corr (p < 2.109010-8 ). Results and Discussion The electrochemical parameters determined from the polarization curves (Figure 2) are given in Table.1. The corrosion current density of titanium grade2 increase with increasing of ph, from 0.013 ma/cm 2 in reference medium to 0,445 ma/cm 2 in ph 2 medium and 2.013 ma/cm 2 in medium saliva ph 2 containing fluoride. Our results have shown that fluoride ions could cause the breakdown of the protective passivation layer, so it s necessary to church inhibitory that suppressed this corrosion. Table1. Summary of electrochemical parameters for titanium grade 2 in different media Electrolyte I corr (ma/cm 2 ) R p (Ω cm 2 ) E(I=0)mV Medium saliva ph=7.03 0.013 5220-795.3 Medium saliva ph=2 0.445 207.26-1488 Medium saliva ph=2+fluoride 2.013 66..5-1520 35

Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride Latifa KINANI and Abdelilah CHTAINI Figure 2. Polarization curves after 2h of immersion in medium saliva ph 2 with and without fluoride The electrochemical parameters determined from the polarization curves (Figure3) are given in Table 2. Figure3. Polarization curves after 2h of immersion in fluoride medium saliva ph2 with and without eugenol 36

Leonardo Journal of Sciences ISSN 1583-0233 Issue 11, July-December 2007 p. 33-40 Table 2. Summary of electrochemical parameters for titanium grade 2 in fluoride medium at different Concentration of eugenol Concentration of eugenol I corr (ma/cm2) R p (Ω cm 2 ) E(I=0) E% 0 2.013 66.5 10-5 M 0.538 164.03-1422.5 73.273 10-3 M 0.167 434.16-1501.9 91.703 10-1 M 0.059 1610-1062.6 97.069 The corrosion current density of titanium grade 2 decrease with increasing concentration of eugenol, from 2,013 ma/cm 2 in reference medium at ph2 containing fluoride (0,1%) to 0,059 ma/cm 2 in 10-1 M concentration of eugenol medium. The results showed that eugenol revealed a good corrosion inhibitor. The inhibition efficiency depends the concentrations of eugenol. An impedance spectroscopy study was performed in order to confirm the results obtained with polarization tests. Figure 4 shown the impedance diagrams recorded for titanium grade 2 in different medium to examine the concentration of eugenol effect. In case fluoride medium at ph2 the impedance curve is in the form of a half-circle which can be attributed to electron transfer step. The diameter of circle increased with increasing the concentration of eugenol. However, at concentration10-1 M of eugenol (Figure 5) the diagrams curve is in the form of three-circle corresponding the formation the tridimentionel film on the surface that suppressed corrosion. Figure 4. Electrochemical impedance spectroscopy for titanium grade 2 in different saliva media 37

Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride Latifa KINANI and Abdelilah CHTAINI Figure 5. Electrochemical impedance spectroscopy for titanium grade 2 fluoride media at ph2 + (10-1 M) eugenol The SEM micrographs (Figure 6) of titanium grade 2 after electrochemical analyses confirmed the electrochemical results They show a general change in the surface of pure titanium in Fusayama Meyer saliva medium, in the much more aggressive fluoridatedacidified saliva medium the metal is characterized by localized pitting. However, the addition of eugenol in fluoride medium at ph2 led the formation of film on the surface which increases the metal resistance. (a) Figure 6. SEM of titanium after test electrochemical a) fluoride media at ph2, b) fluoride media at ph = 2+eugenol (b) 38

Leonardo Journal of Sciences ISSN 1583-0233 Issue 11, July-December 2007 p. 33-40 Conclusion Behaviour of titanium in a solution containing fluoride and eugenol were studied electrochemical properties, surface analyses by SEM and ph. These results are summarized as following: 1. The corrosion resistance of titanium specimens solution containing. Fluoride decreased in comparison with that in a solution not containing fluoride. Adding eugenol to the solution resulted in preventing the corrosion of the titanium from the fluoride. 2. The rate corrosion of titanium in acidic medium saliva (ph =2) was clearly lower than that in the solution containing fluoride at ph = 2. From these results, the effects of eugenol are not only the protection of titanium from fluoride attack but also the suppression of dissolution of titanium ions via formation of the eugenol films. These effects evidently suppress the corrosion of titanium by fluoride. References 1. Hanawa T., Ota M., Characterization of surface.lm formed on titanium in electrolyte usingxps, Appl Surf Sci, 1992, 55, p. 269-276. 2. Ong J. L., Lucas L. C., Raikar G.N., Connatser R., Gregory J. C., Spectroscopic characterization of passivated titanium in a physiologic solution, J Mater Sci Mater Med, 1995, 6, p. 1131-119. 3. Hanawa T., Asami K., Asaoka K., Repassivation of titanium and surface oxide.lm regenerated in simulated bioliquid, J Biomed Mater Res, 1998, 40, p. 530-538. 4. Lausmaa J., Kasemo B., Hansson S., Accelerated oxide grown on titanium implants duringautoclavin g caused by uorine contamination, Biomaterials, 1985, 6, p. 23-27. 5. Wilhelmsen W., Grande A. P., The in.uence of hydro.uoric acid and.uoride ion on the corrosion and passive behavior of titanium, Electrochim Acta, 1987, 32(10), p. 1469-1472. 6. Boere G., Influence of.uoride on titanium in an acidic environment measured by polarization resistance technique, J Appl Biomater, 1995, 6, p. 283-288. 39

Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride Latifa KINANI and Abdelilah CHTAINI 7. Oda Y., Kawada E., Yoshinari M., Hasegawa K., Okabe T., The in.uence of.uoride concentration on the corrosion of titanium and titanium alloys, Jpn J Dent Mater, 1996, 15, p. 317-322. 8. Reclaru L., Meyer J.-M., Effects of fluorides on titanium and other dental alloys in dentistry, Biomaterials 1998, 19, p. 85-92. 9. Nakagawa M., Matsuya S., Shiraishi T., Ohta M., Effect of.fluoride concentration and ph on corrosion behavior of titanium for dental use, J Dent Res, 1999, 78(9), p. 1568-1572. 10. Nakagawa M., Matsuya S., Udoh K., Corrosion behavior of pure titanium and titanium alloys in.uoride-containingsolutions, Dent Mater J, 2001, 20(4), p. 305-314. 11. Nakagawa M., Matsuya S., Udoh K., Effect of fluoride and dissolved oxygen concentrations on the corrosion behaviour of pure titanium and titanium alloys, Dent Mater J, 2002, 21(2), p. 83-92. 12. Schiff N., Grosgogeat B., Lissac M., Dalard F., Influence of fluoride content and ph on the corrosion resistance of titanium and its alloys, Biomaterials, 2002, 23, p. 1995-2002. 40