Trifecta vs. Magna for Aortic Valve Replacement. Differences in Clinical Outcome and Valve Hemodynamics

Similar documents
Does Patient-Prosthesis Mismatch Affect Long-term Results after Mitral Valve Replacement?

How to Avoid Prosthesis-Patient Mismatch

Management of Difficult Aortic Root, Old and New solutions

Indication, Timing, Assessment and Update on TAVI

16 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 6900

CLINICAL COMMUNIQUE 16 YEAR RESULTS

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

Hemodynamics Benefit of Supra-Annular Design in Failed Bio-Prosthetic Valves

Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience

A Surgeon s Perspective Guidelines for the Management of Patients with Valvular Heart Disease Adapted from the 2006 ACC/AHA Guideline Revision

TAVI Versus Suturless Valve In Intermediate Risk Patients

Incidence of prosthesis-patient mismatch in patients receiving mitral Biocor porcine prosthetic valves

Department of Cardiothoracic Surgery, Heart and Lung Center, Lund University Hospital, Lund, Sweden

Incorporating the intermediate risk in Transcatheter Aortic Valve Implantation (TAVI)

Ann Thorac Cardiovasc Surg 2015; 21: Online April 18, 2014 doi: /atcs.oa Original Article

TAVR-Update Andrzej Boguszewski MD, FACC, FSCAI Vice Chairman, Cardiology Mid-Michigan Health Associate Professor Michigan State University, Central

The operative mortality rate after redo valvular operations

Surgical AVR: Are there any contraindications? Pyowon Park Samsung Medical Center Seoul, Korea

Transcatheter valve-in-valve implantation for degenerated surgical bioprostheses

42yr Old Male with Severe AR Mild LV dysfunction s/p TOF -AV Replacement(tissue valve) or AoV plasty- Kyung-Hwan Kim

Magdalena Erlebach 1, Michael Wottke 1, Marcus-André Deutsch 1, Markus Krane 1, Nicolo Piazza 2, Ruediger Lange 1, Sabine Bleiziffer 1

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

Long-term results (22 years) of the Ross Operation a single institutional experience

Bicuspid aortic root spared during ascending aorta surgery: an update of long-term results

Valve Disease in Patients With Heart Failure TAVI or Surgery? Miguel Sousa Uva Hospital Cruz Vermelha Lisbon, Portugal

Role of Sutureless Valves in the Surgeon s Armamentarium Prof. Dr Malakh Shrestha Vice Chair, Director of Aortic Surgery Cardiothoracic,

Cover Page. The handle holds various files of this Leiden University dissertation

Expanding Relevance of Aortic Valve Repair Is Earlier Operation Indicated?

CoreValve in a Degenerative Surgical Valve

Tissue vs Mechanical What s the Data??

TAVR 2018: TAVR has high clinical efficacy according to baseline patient risk! ii. Con

Presenter Disclosure. Patrick O. Myers, M.D. No Relationships to Disclose

Durability and Outcome of Aortic Valve Replacement With Mitral Valve Repair Versus Double Valve Replacement

Hani K. Najm MD, Msc, FRCSC FACC, FESC President Saudi Society for Cardiac Surgeons Associate Professor of Cardiothoracic Surgery King Abdulaziz

Transcatheter Aortic Valve Implantation in Patients With Concomitant Mitral and Tricuspid Regurgitation

2/15/2018 DISCLOSURES OBJECTIVES. Consultant for BioSense Webster, a J&J Co. Aortic stenosis background. Short history of TAVR

Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data

15-Year Comparison of Supra-Annular Porcine and PERIMOUNT Aortic Bioprostheses

Medtronic Mosaic porcine bioprosthesis: Assessment of 12-year performance

Prof. Patrizio LANCELLOTTI, MD, PhD Heart Valve Clinic, University of Liège, CHU Sart Tilman, Liège, BELGIUM

Reoperation for Bioprosthetic Mitral Structural Failure: Risk Assessment

Appropriate Patient Selection or Healthcare Rationing? Lessons from Surgical Aortic Valve Replacement in The PARTNER I Trial Wilson Y.

Prosthesis-Patient Mismatch in High Risk Patients with Severe Aortic Stenosis in a Randomized Trial of a Self-Expanding Prosthesis

Percutaneous Treatment of Valvular Heart Diseases: Lessons and Perspectives. Bernard Iung Bichat Hospital, Paris

Transapical Transcatheter Aortic Valve Implantation in the Presence of a Mitral Prosthesis

TSDA Boot Camp September 13-16, Introduction to Aortic Valve Surgery. George L. Hicks, Jr., MD

TAVR in patients with. End-Stage CKD or in Renal Replacement Therapy:

Prosthesis-Patient Mismatch or Prosthetic Valve Stenosis?

Outcome of Next-Generation Transcatheter Valves in Small Aortic Annuli: A Multicenter Propensity-Matched Comparison

Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

Kinsing Ko, Thom de Kroon, Najim Kaoui, Bart van Putte, Nabil Saouti. St. Antonius Hospital, Nieuwegein, The Netherlands

Hani K. Najm MD, Msc, FRCSC, FRCS (Glasgow), FACC, FESC President of Saudi Heart Association King Abdulaziz Cardiac Centre Riyadh, Saudi Arabia.

A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis

Clinical material and methods. Copyright by ICR Publishers 2003

Treatment of Bio-Prosthetic Valve Deterioration Using Transcatheter Techniques

Peri-operative results and complications in 15,964 transcatheter aortic valve implantations from the German Aortic valve RegistrY (GARY)

Echocardiographic Evaluation of Mitral Valve Prostheses

Introducing the COAPT Trial

Mitral Gradients and Frequency of Recurrence of Mitral Regurgitation After Ring Annuloplasty for Ischemic Mitral Regurgitation

Reconstruction of the intervalvular fibrous body during aortic and

Dr.ssa Loredana Iannetta. Centro Cardiologico Monzino

TAVR for low-risk patients in 2017: not so fast.

2/28/2010. Speakers s name: Paul Chiam. I have the following potential conflicts of interest to report: NONE. Antegrade transvenous transseptal route

Is TAVR Now Indicated in Even Low Risk Aortic Valve Disease Patients

1-YEAR OUTCOMES FROM JOHN WEBB, MD

Persistent Tricuspid Regurgitation After Tricuspid Annuloplasty During Redo Valve Surgery Affects Late Survival and Valve-Related Events

Copyright by ICR Publishers 2014

Case. 15-year-old boy with bicuspid AV Severe AR with moderate AS. Ross vs. AVR (or AVP)

Influence of patient gender on mortality after aortic valve replacement for aortic stenosis

LOW RISK TAVR. WHAT THE FUTURE HOLDS

Stainless Steel. Cobalt-chromium

TAVR IN INTERMEDIATE-RISK PATIENTS

Mechanical vs. Bioprosthetic Aortic Valve Replacement: Time to Reconsider? Christian Shults, MD Cardiac Surgeon, Medstar Heart and Vascular Institute

TAVR: Intermediate Risk Patients

PARTNER 2A & SAPIEN 3: TAVI for intermediate risk patients

Results of Transfemoral Transcatheter Aortic Valve Implantation

Echocardiographic Evaluation of Aortic Valve Prosthesis

The Ross Procedure: Outcomes at 20 Years

Successful Transfemoral Edwards Sapien Aortic. Valve Implantation in a Patient with Previous. Mitral Valve Replacement

Imaging in TAVI. Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013

Transcatheter Aortic Valve Replacement

Severe left ventricular dysfunction and valvular heart disease: should we operate?

Early and One-year Outcomes of Aortic Root Surgery in Marfan Syndrome Patients

Alec Vahanian,FESC, FRCP (Edin.) Bichat Hospital University Paris VII, Paris, France

TAVI IN BICUSPID AOV AND VALVE-IN-VALVE

Prof. Dr. Thomas Walther. TAVI in ascending aorta / aortic root dilatation

Portico (St. Jude Medical Inc, St.

PPM: How to fit a big valve in a small heart

Edwards Transcatheter AVR: Have the Outcomes Changed after CE Approval?

Transcatheter Aortic Valve Implantation. SSVQ November 23, 2012 Centre Mont-Royal 15:40

Multicentre clinical study evaluating a novel resheatable self-expanding transcatheter aortic valve system

Which Type of Secondary Tricuspid Regurgitation Accompanying Mitral Valve Disease Should Be Surgically Treated?

Aortic Stenosis: Background

Paris, August 28 th Gian Paolo Ussia on behalf of the CoreValve Italian Registry Investigators

Echocardiographic Evaluation of Aortic Valve Prosthesis

Management of High-Risk Patients With Aortic Stenosis and Coronary Artery Disease

Ian T. Meredith AM. MBBS, PhD, FRACP, FCSANZ, FACC, FAPSIC. Monash HEART, Monash Health & Monash University Melbourne, Australia

ORIGINAL PAPER. The long-term results and changing patterns of biological valves at the mitral position in contemporary practice in Japan

Valve prosthesis-patient mismatch (PPM) was first defined

Sotirios N. Prapas, M.D., Ph.D, F.E.C.T.S.

Transcription:

Circ J 2018; 82: 2767 2775 doi: 10.1253/circj.CJ-18-0744 ORIGINAL ARTICLE Cardiovascular Surgery Trifecta vs. Magna for Aortic Valve Replacement Differences in Clinical Outcome and Valve Hemodynamics Naoki Tadokoro, MD; Satsuki Fukushima, MD, PhD; Yusuke Shimahara, MD; Yorihiko Matsumoto, MD; Kizuku Yamashita, MD; Naonori Kawamoto, MD; Kimito Minami, MD, PhD; Junjiro Kobayashi, MD, PhD; Tomoyuki Fujita, MD, PhD Background: The number of surgical aortic valve replacements using bioprosthetic valves is increasing, and newer bioprosthetic valves may offer clinical advantages in Japanese patients, who generally require smaller replacement valves than Western patients. In this study we retrospectively evaluated the Trifecta and Magna valves to compare clinical outcomes and hemodynamics in a group of Japanese patients. Methods and Results: Data were retrospectively collected for 103 patients receiving a Trifecta valve and 356 patients receiving a Magna valve between June 2008 and 2017. Adverse events, outcomes, and valve hemodynamics were evaluated. There were no significant differences in early or late outcomes between the Trifecta and Magna groups. In the early postoperative period, mean (±SD) pressure gradient (9.0±3.1 vs. 13.8±4.8 mmhg; P<0.01) and effective orifice area (1.68±0.46 vs. 1.46±0.40 m 2 ; P<0.01) were significantly better for Trifecta, but the differences decreased over time. In particular, the interaction between time and valve type (Trifecta or Magna) was significantly different for mean pressure gradient between the 2 groups (P<0.01). Left ventricular mass regressed substantially in both groups, with no significant difference between them. There were no significant differences for severe patient-prosthesis mismatch. Conclusions: Postoperative outcomes were similar for both valves. An early hemodynamic advantage for the Trifecta valve lasted to approximately 1 year postoperatively but did not persist. Key Words: Aortic valve replacement; Bioprosthetic valve; Japan; Magna; Trifecta The number of surgical aortic valve replacements (AVRs) using a bioprosthesis is increasing according to the annual surveys of thoracic surgery by the Japanese association for thoracic surgery (http://www. jpats.org/modules/investigation/index.php?content_id=7), which states that bioprostheses are used in three-quarters of all AVR procedures. In addition, the age limit for implantation of an aortic bioprosthesis is continuously being shifting down, 1 with bioprostheses used for AVR in 60% of sexagenarian patients and 90% of septuagenarian or octogenarian patients. 2 This may be related to the enhanced durability of new-generation bioprostheses, improved outcomes of redo valve replacement surgery, or the development of valve-in-valve (ViV) transcatheter aortic valve implantation. 3 The new-generation bioprostheses, including the Trifecta (St. Jude Medical, St. Paul, MN, USA) or the Carpentier- Edwards Perimount Magna or Magna Ease (Edwards Lifesciences, Irvine, CA, USA), reportedly have design advantages in terms of their large effective orifice area (EOA) and low pressure gradients, as well as in terms of the materials used, including anticalcification treatment, which potentially results in good hemodynamics and avoids patient-prosthesis mismatch. 4 In addition, the newgeneration bioprostheses have long-term durability. The valve leaflets of both the Trifecta and Magna prostheses are generated by glutaraldehyde-treated bovine pericardium but differ in their preparation and design. These fundamental differences may result in clinically prominent differences in their hemodynamics that should be considered particularly for Japanese patients, who have a small aortic annulus relative to their body size and require a smaller prosthesis than Western patients. 5 Therefore, the aims of this study were to review clinical outcomes at the National Cerebral and Cardiovascular Center after AVR using either valve and to compare the hemodynamic performance of each valve. Received June 27, 2018; revised manuscript received July 30, 2018; accepted August 3, 2018; released online September 15, 2018 Time for primary review: 23 days Department of Cardiovascular Surgery (N.T., S.F., Y.S., Y.M., K.Y., N.K., J.K., T.F.), Department of Surgical Intensive Care (K.M.), National Cerebral and Cardiovascular Center, Suita, Japan Mailing address: Tomoyuki Fujita, MD, PhD, Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, Suita 565-8565, Japan. E-mail: tfujita@ncvc.go.jp ISSN-1346-9843 All rights are reserved to the Japanese Circulation Society. For permissions, please e-mail: cj@j-circ.or.jp

2768 TADOKORO N et al. Table 1. Patient Characteristics Trifecta (n=103) Magna (n=356) P-value Age (years) 72.9±8.3 69.0±9.9 <0.01 Sex (M/F) 49/54 213/143 0.212 Body surface area (m 2 ) 1.57±0.19 1.60±0.19 0.206 Valve disease Aortic stenosis 63 (61.8) 217 (61.0) 0.909 Aortic insufficiency 18 (17.6) 58 (16.3) 0.763 Mixed 12 (11.8) 32 (9.0) 0.446 Valve pathology Bicuspid aortic valve 23 (23.7) 103 (30.7) 0.206 Degenerative/rheumatic 52 (53.6) 179 (53.1) 1.000 Infective endocarditis 5 (4.9) 10 (2.8) 0.341 Cardiac comorbidity Coronary stenosis 24 (23.5) 68 (19.1) 0.329 History of PCI 4 (3.9) 22 (6.2) 0.474 Atrial fibrillation 20 (19.4) 73 (20.5) 0.890 Previous cardiac surgery 11 (10.7) 33 (9.3) 0.704 Non-cardiac comorbidity Hypertension 80 (77.7) 272 (76.4) 0.895 Hyperlipidemia 50 (48.5) 172 (48.3) 1.00 Diabetes 26 (25.2) 61 (17.1) 0.086 Diabetes with insulin treatment 2 (1.9) 6 (1.7) 1.00 COPD 30 (29.1) 76 (21.3) 0.111 Smoking 33 (32.0) 124 (34.8) 0.638 HbA1c (%) 5.7±0.6 5.6±0.7 0.09 Prior stroke 13 (12.6) 26 (7.3) 0.107 Carotid stenosis 5 (4.9) 11 (3.1) 0.37 Peripheral arterial disease 4 (3.9) 13 (3.7) 1.00 Chronic kidney disease 9 (8.7) 26 (7.3) 0.673 Dialysis 1 (1.0) 7 (2.0) 0.69 NYHA class I 2 (1.9) 13 (3.7) 0.538 II 83 (80.6) 307 (86.2) 0.161 III 15 (14.5) 32 (9.0) 0.138 IV 3 (2.9) 4 (1.1) 0.191 BNP (pg/ml) 281±531 263±530 0.767 Preoperative echocardiography LVDd (mm) 51.1±8.8 53.2±10.9 0.079 LVDs (mm) 34.1±10.7 35.8±11.3 0.162 LVEF (%) 57.3±15.3 56.0±13.1 0.406 LVMI (g/m 2 ) 128.9±38.9 137.7±47.1 0.085 Preoperative AVA (cm 2 ) 0.79±0.29 0.76±0.23 0.299 Preoperative AVAi (cm 2 ) 0.50±0.19 0.49±0.15 0.482 Preoperative MPG (mmhg) 52.0±22.4 48.7±17.9 0.183 Risk score (%) EuroSCORE II 2.9±2.4 3.3±4.3 0.413 Data are presented as mean ± SD or n (%). AVA, aortic valve area; AVAi, aortic valve area index; BNP, B-type natriuretic peptide; COPD, chronic obstructive pulmonary disease; EuroSCORE, European System for Cardiac Operative Risk Evaluation; LVDd, left ventricular internal diameter in diastole; LVDs, left ventricular internal diameter in systole; LVEF, left ventricular ejection fraction; LVMI, left ventricular mass index; MPG, mean pressure gradient; NYHA, New York Heart Association; PCI, percutaneous coronary intervention. Methods Study Cohort and Data Collection This study was an observational single-center cohort study. The institutional surgical database contained a con- secutive series of 876 patients who underwent surgical AVR with a prosthetic valve at the National Cerebral and Cardiovascular Center between June 2008 and 2017. Mechanical prosthetic valves were implanted in 162 patients (18.5%), whereas the remaining 714 patients (81.5%)

Replacement Valve Choice in Japanese Patients 2769 Table 2. Intraoperative Variables Trifecta (n=103) Magna (n=356) P-value Procedure Isolated AVR 49 (48.0) 176 (49.4) 0.823 MICS procedure 0 13 (3.7) 1.000 Concomitant procedure Ascending aorta surgery 13 (12.7) 33 (9.3) 0.349 Mitral valve surgery 15 (14.7) 58 (16.3) 0.761 Tricuspid valve repair 9 (8.8) 27 (7.6) 0.679 CABG 23 (22.5) 71 (19.9) 0.579 Maze procedure 13 (12.7) 43 (12.1) 0.864 Operation time (min) 312±101 304±84 0.395 ACC time (min) 104±36 101±36 0.339 CPB time (min) 147±46 147±45 0.839 Prosthesis size (mm) 19 36 (35.0) 92 (25.8) 0.081 21 24 (23.3) 112 (31.5) 0.113 23 35 (34.0) 92 (25.8) 0.106 25 8 (7.8) 39 (11.0) 0.460 27 0 21 (5.9) Data are presented as mean ± SD or number (%). ACC, aortic cross-clamp time; AVR, aortic valve replacement; CABG, coronary artery bypass grafting; CPB, cardiopulmonary bypass; MICS, minimally invasive cardiac surgery. underwent AVR with a stented bioprosthetic valve, such as the Trifecta (n=110 patients; 12.6%), Magna (n=374 patients; 42.7%), Mosaic (Medtronic, Minneapolis, MN, USA; n=185 patients; 21.1%), or Crown/Mitroflow (Sorin, Milan, Italy; n=45 patients; 5.1%) valves. Patients who underwent concomitant surgical procedures that potentially affected the clinical outcome and valve hemodynamics, such as septal myectomy or root enlargement, were excluded from this study. In addition, redo cases were excluded from the study because the aortic annulus, which is the critical structure in determining the hemodynamics of the prosthetic valve, is often deformed by the scar tissue and/or possibly by the surgical manipulation. Consequently, 103 patients with a Trifecta valve and 356 patients with Magna valve were evaluated in this study. Follow-up was completed for 102 patients (99.0%) with a Trifecta valve and 340 patients (95.5%) with a Magna valve. Data were collected by reviewing patients medical charts, surgical reports, and referral letters, supplemented by telephone interviews for patients under the care of distant physicians. Major adverse cardiac and cerebrovascular events (MACCE) were classified according to the standard definitions. 6 Events were classified as occurring early (within 30 days of implantation) or late (>31 days after implantation). Data collection was performed between January and February 2018. All patients gave written informed consent for surgery and the use of their data for diagnostic and research purposes prior to the surgery. The Institutional Review Board of the National Cerebral and Cardiovascular Center waived ethics compliance for this retrospective study. Patient Background and Characteristics Information regarding patient background and characteristics were retrieved from the medical charts. Prosthesis type and size were determined intraoperatively by individual surgeons as the best-matched prosthesis for each patient. In the Magna group, 134 patients (37.6%) received a Magna valve and 222 patients (62.4%) received the Magna Ease valve, which was introduced in the National Cerebral and Cardiovascular Center in 2011; the Trifecta valve was introduced in 2012. Patients in both groups underwent clinical and echocardiographic assessment preoperatively, on hospital discharge, 1 year postoperatively, and during follow-up (range 2 10 years). Surgical Indications, Procedure, and Postoperative Care Although the surgical indications for AVR were determined by the institutional heart team essentially according to recommended guidelines, 7,8 the prosthesis type was determined by the patient and their surgeon to select the best-matched type and size. As a result, there was no significant difference in patient background or characteristics between the Trifecta and Magna groups, with the exception of patient age at surgery (Table 1). The age difference may be secondary to the transcatheter ViV procedure, in which implantation is reportedly easier for the Magna than Trifecta valve. 9 Surgical AVR was performed via a median sternotomy in all patients in the Trifecta group and in 343 patients (96.3%) in the Magna group, whereas a minimally invasive approach, such as an upper partial sternotomy or right minithoracotomy, was used in 13 patients in the Magna group (Table 2). Prosthetic valve size or concomitant surgical procedures were not significantly different between the 2 groups. Postoperatively, aspirin 100 mg/day was given until the latest follow-up, whereas warfarin was given to a target international normalized ratio (INR) of 1.5 2.5 for 3 months unless patients required anticoagulant therapy, such as those with atrial fibrillation. Following hospital discharge, patients were reassessed in the outpatient clinic or by a distant physician every 3 months until the latest follow-up.

2770 TADOKORO N et al. Table 3. Clinical Outcomes Trifecta (n=103) Magna (n=356) P-value Follow-up period (months) 31.0 [15.0 42.0] 36.0 [15.0 64.0] <0.01 Follow-up rate 102 (99.0) 340 (95.5) 0.137 Early MACCE 2 (1.9) 7 (2.0) 1.00 30-day mortality 1 (1.0) 1 (0.3) 0.399 Cerebrovascular accidents (stroke) 0 2 (0.6) 1.00 Permanent pacemaker implant 0 3 (0.8) 1.00 Heart failure 1 (1.0) 0 0.224 Perioperative myocardial infarction 0 1 (0.3) 1.00 Late MACCE 14 (13.6) 60 (16.9) 0.543 Late mortality 4 (3.9) 17 (4.8) 1.00 Cardiac cause 0 4 (1.1) 0.579 Cerebral hemorrhage 0 3 (0.8) 1.00 Pneumonia 2 (1.9) 4 (1.1) 0.62 Cancer 1 (1.0) 1 (0.3) 0.399 Septic shock 0 1 (0.3) 1.00 Unknown cause 1 (0.9) 4 (1.1) 1.00 Cerebrovascular accidents (stroke) 2 (1.9) 13 (3.7) 0.538 Permanent pacemaker implant 0 15 (4.2) 0.028 Heart failure 4 (3.9) 9 (2.5) 0.5 Acute aortic dissection 0 3 (0.8) 1.00 Reintervention 2 (1.9) 8 (2.2) 1.00 SVD 0 1 (0.3) 1.00 PVE 2 (1.9) 6 (1.7) 1.00 PVL 0 1 (0.3) 1.00 Other operation 2 (1.9) 2 (0.6) 1.00 Data are presented as the median [interquartile range] or n (%). MACCE, major adverse cardiac and cerebrovascular event; PVE, prosthetic valve endocarditis; PVL, paravalvular leak; SVD, structural valve deterioration. Transthoracic Echocardiography All patients underwent the National Cerebral and Cardiovascular Center s standard 2-dimensional transthoracic echocardiography preoperatively, and 5 7 days after AVR; however, 82 patients (79.6%) in the Trifecta group and 251 patients (70.5%) in the Magna group underwent echocardiography 1-year after AVR. In addition, 58 patients (56.3%) in the Trifecta group and 181 patients (50.8%) in the Magna group underwent echocardiography at a mean interval from surgery of 35 months (range 30 40.5 months) and 48 months (range 31.5 71.0 months), respectively. Standard parameters were measured based on the recommendations of the American Society of Echocardiography. 10 Briefly, Doppler flow data were acquired from the left ventricular outflow tract just proximal to the prosthesis sewing ring. The modified Bernoulli equation was used to calculate peak and mean pressure gradient (MPG) across the prosthetic valve. EOA was calculated using a continuity equation on echo Doppler assessments. Patient-prosthesis mismatch, which was calculated as indexed EOA (ieoa)/ body surface area, was classified as not clinically significant (ieoa >1 cm 2 /m 2 ), mild (ieoa 0.85 1 cm 2 /m 2 ), moderate (ieoa 0.65 0.85 cm 2 /m 2 ), or severe (ieoa <0.65 cm 2 /m 2 ). 11 Left ventricular mass (LVM; g) was calculated using the following formula and indexed to body surface area (LMVi): LVM (g)=0.8 (1.04 ([LVDd+PWTd+ISTd] 3 LVDd 3 ))+0.6 where LVDd is left ventricular internal diameter in dias- tole, PWTd is posterior wall thickness in diastole, and ISTd is interventricular septum thickness in diastole. The effect of LVMi regression was evaluated by comparing preoperative values with those in each postoperative period (at discharge, 1 year postoperatively, and follow-up). The measured parameters were recorded in the official echocardiographic report, which was retrieved as data for this study. Statistical Analysis Continuous variables are presented as the mean ± SD, whereas categorical variables are presented as frequencies and percentages. Survival and event-free survival rates were calculated using the Kaplan-Meier method with 95% confidence intervals (CIs). Hemodynamic primary endpoints were interactions between time points (discharge, 1 year postoperatively, and at each follow-up) and valve type (Trifecta vs. Magna) for MPG, EOA, and LVMi after adjusting for the following baseline characteristics: age, sex, body surface area, valve size, history of hypertension, dyslipidemia, diabetes, chronic kidney disease, atrial fibrillation, coronary artery disease, carotid artery stenosis, prior stroke, peripheral arterial disease, smoking habit, preoperative New York Heart Association class, 12 preoperative European System for Cardiac Operative Risk Evaluation (EuroSCORE), 13 preoperative ejection fraction, preoperative stroke volume, type of valve disease, tricuspid valve, bicuspid valve, and etiology of the valve disease. Linear model estimation using ordinary least

Replacement Valve Choice in Japanese Patients 2771 squares and the Huber-White method was used to adjust the variance covariance matrix of a fit from least squares to correct for heteroscedasticity and for correlated responses from patients. A multivariate covariance analysis model was constructed to further compare the primary study endpoints (MPG, EOA, and LVMi) at the 1-year follow-up. The second endpoint was analysis of the overall survival and freedom from MACCE, using the preoperative variables for the regression analysis. A validated statistical linear mixed model was used to analyze the effect of each prosthetic valve function (the hemodynamic parameters). Continuous variables without repeated measures were tested using an unpaired t-test, whereas continuous variables with repeated measures were tested using a paired t-test; ordinal variables were tested using the Mann-Whitney U-test. Categorical variables were tested using the Chi-squared test, and 2-sided statistics were performed with significance set at a level of 0.05. Statistical analyses were performed using R 3.4.3 (R Foundation for Statistical Computing, Vienna, Austria). Results Outcomes at 30 Days Either Trifecta (n=103) or Magna (n=356) valves were used for AVR in patients in this study. One patient died in each group from thromboembolic events within 30 days postoperatively (Table 3). Cerebrovascular accidents occurred in 2 patients (0.6%) in the Magna group, whereas new permanent pacemaker implantation was performed for complete atrioventricular block in 3 patients (0.8%) in the Magna group. Perioperative myocardial infarction occurred in 1 patient in the Magna group. In this patient, thromboembolic occlusion of the left anterior descending artery occurred 12 h after the end of surgery, which was successfully treated by transcatheter thrombectomy. As a result, there was no significant difference in the 30-day outcome between the 2 groups. Long-Term Outcomes Patient follow-up was completed at the end of the study in 102 patients (99.0%) in the Trifecta group and in 340 patients (95.5%) in the Magna group (P=0.09), with a mean follow-up of 31.0 months (range 15.0 42.0 months) and 36.0 months (range 15.0 64.0 months), respectively (P<0.01). This significant difference is explained by the fact that the Magna valve was market released prior to the Trifecta valve. As a result, there were 4 deaths (3.9%) in the Trifecta group and 17 deaths (4.8%) in the Magna group by the end of the study. Actuarial survival in the Trifecta group was 99.0% at 1 year and 93.5% at 3 years, whereas in the Magna group it was 98.5% at 1 year and 96.3% at 3 years (log-rank, P=0.263; Figure 1A). Long-term MACCE included cerebrovascular accidents in 2 patients (1.9%) in the Trifecta group and in 13 patients (3.7%) in the Magna group. A permanent pacemaker was implanted after discharge in 15 patients in the Magna group only. Prosthetic valve endocarditis was diagnosed in 2 patients (1.9%) in the Trifecta group and in 6 patients (1.7%) in the Magna group. One patient in the Magna group experienced structural valve deterioration. As a result, freedom from MACCE in the Trifecta group was 93.9% at 1 year and 79.9% at 3 years, whereas in the Magna group it was 94.1% at 1 year and 82.0% at 3 years (log rank, P=0.662; Figure 1B). There was no significant Figure 1. Long-term (A) survival and (B) freedom from major adverse cardiac and cerebrovascular events after aortic valve replacement with the Trifecta and Magna valves assessed using the Kaplan-Meier method and compared using the logrank test. difference in the incidence of MACCE between the 2 groups using logistic regression analysis (odds ratio [OR] 1.26; P=0.434) and proportional odds regression analysis (OR 1.27; P=0.413). Difference in Valve Hemodynamics: Trifecta vs. Magna All patients underwent transthoracic echocardiography preoperatively, at discharge, and annually thereafter. Unadjusted average MPG for all valve sizes at discharge was significantly lower in the Trifecta than Magna group (9.0±3.1 vs. 13.8±4.8 mmhg, respectively; P<0.01). One year postoperatively, mean MPG for all sizes was significantly lower in the Trifecta than Magna group (10.9±3.8 vs. 12.7±5.3 mmhg, respectively; P<0.01), whereas there was no significant difference in MPG for 19-, 21-, and 25-mm valves at 1 year between the 2 groups. There was also no significant difference in MPG for all valve sizes between the 2 groups at the latest follow-up (11.1±4.1 vs. 12.4±4.6 mmhg in the Trifecta and Magna groups, respectively; P=0.062, Figure 2A). Interactions between time points (discharge, 1 year postoperatively, and at the latest follow-up) and valve type (Trifecta or Magna) for MPG were significantly different between the 2 groups (P<0.01), indicating that MPG was significantly lower in the Trifecta group soon after surgery, but thereafter the difference between groups was smaller (Figure 2B).

2772 TADOKORO N et al. Figure 2. Transthoracic echocardiographic assessment of the mean pressure gradient (MPG) for each valve: (A) unadjusted (actual) data and (B) interaction between time points (at discharge, 1 year postoperatively, at follow-up) and valve type (Trifecta vs. Magna). EOA showed a consistent trend regarding MPG (Figure 3A). Average EOA for all valve sizes at discharge was significantly larger in the Trifecta than Magna group (1.68±0.46 vs. 1.46±0.40 cm 2, respectively; P<0.01), whereas average EOA for each valve size was significantly larger for the Trifecta than Magna group. One-year postoperatively, mean EOA for all valve sizes was significantly larger in the Trifecta than Magna group (1.64±0.40 vs. 1.50±0.42 cm 2, respectively; P=0.01), whereas there was no significant difference in the EOA for the 23- or 25-mm valves between the 2 groups. At the latest follow-up, there was a significant difference in EOA only for the 21-mm valve. Interestingly, EOA in the Magna group remained unchanged, whereas that of the Trifecta group appeared to decrease over the study period (Figure 3B). There was no significant difference in EOA between the 2 groups over the study period. LVM Regression LVM was calculated based on transthoracic echocardiographic data. The LVMi regression rate was defined by the ratio of LVMi at each time point to preoperative LVMi. There was a steady decrease in LVMi in both groups over the study period, reaching a 25±29.1% and 29.1±18.8% reduction in the Trifecta and Magna groups, respectively (Figure 4A). LVMi reduction appeared to predominate in the Magna compared with Trifecta group, although the difference was not statistically significant (Figure 4B). Patient-Prosthesis Mismatch After AVR There was no significant difference in the incidence of severe patient-prosthesis mismatch in either group over the study period. Severe patient-prosthesis mismatch was observed in 5 patients (4.8%) in the Trifecta group and in 38 patients (10.7%) in the Magna group at discharge (log-

Replacement Valve Choice in Japanese Patients 2773 Figure 3. Transthoracic echocardiographic assessment of the effective orifice area (EOA) for each valve: (A) unadjusted (actual) data and (B) interaction between time points (at discharge, 1 year postoperatively, at follow-up) and valve type (Trifecta vs. Magna). rank test, P=0.0595), in 3 (2.9%) and 21 (5.9%) patients, respectively, at 1 year (log-rank test, P=0.218), and in 3 (2.9%) and 20 (5.6%) patients, respectively, at the latest follow-up (log-rank test, P=0.211). Discussion This study compared institutional clinical and hemodynamic outcomes after AVR using Trifecta and Magna bioprostheses. Neither in-hospital nor midterm clinical outcomes were significantly different when comparing the 2 valves because patient characteristics and surgical procedures did not differ significantly, including the size of the prosthesis selected. Echocardiographically, MPG across the prosthetic valve was significantly lower in the Trifecta than Magna group soon after surgery; however, this differ- ence decreased over the study period. EOA of the prosthetic valve showed a similar trend to MPG soon after surgery, with no significant difference in EOA between the groups over the study period. LVM regressed substantially in both groups, with no significant difference in the degree of regression between the 2 groups over the study period. In addition, there was no significant difference in the incidence of severe patient-prosthesis mismatch between the groups over the study period. A hemodynamic advantage was echocardiographically more prominent for the Trifecta than Magna valve soon after surgery. We attributed this to the design of the valves, with the valve leaflets mounted outside the sewing ring on the Trifecta valve and inside the sewing ring on the Magna valve, which created a larger orifice area on the Trifecta valve. This hemodynamic advantage gradually diminished

2774 TADOKORO N et al. Figure 4. Transthoracic echocardiographic assessment of left ventricular mass index (LVMi) for each valve: (A) unadjusted (actual) data and (B) interaction between time points (at discharge, 1 year postoperatively, at follow-up) and valve type (Trifecta vs. Magna). over time, and was related, at least in part, to an immunological reaction with the deposition of platelets and subsequent fibrin formation with leaflet thickening and pannus formation. 14 However, further follow-up and/or an in vivo study are required to prove this theory. One may claim that the hemodynamic advantage of the Trifecta valve was not reflected in our clinical outcomes regarding the degree of LVM regression or patient-prosthesis mismatch. Possible reasons for this are the small number of patients and/or, possibly more importantly, the relatively short period of the hemodynamic advantage, which was insufficient to produce substantial differences in the outcomes, including LVM regression, even in Japanese patients, and the relatively small size of the prosthesis compared with those used in Western patients. Redo valve surgery may be required in patients undergoing bioprosthetic valve replacement, and the aortic ViV procedure is an option in these patients. Therefore, it is important to select the valve prosthesis while considering possible future aortic ViV. Because the Trifecta valve has externally mounted leaflets with a rigid sewing cuff, aortic ViV with a Trifecta valve reportedly has the following disadvantages: (1) expanding the externally mounted Trifecta leaflets potentially obstructs the coronary artery ostia; 9 and (2) ViV then requires a smaller transcatheter heart valve size than the implanted valve, which has a rigid sewing cuff that cannot be broken by balloon expansion. In fact, it was reported that aortic ViV with the 26-mm Sapien XT (Edwards Lifesciences) over a 25-mm Trifecta valve led to significantly high coronary obstruction rates compared with the 23-mm Sapien XT, 15 although some reports state that aortic ViV was safely performed over the 23-mm Trifecta valve using a St. Jude Medical Portico 23-mm valve or a 23-mm Medtronic Core-Valve Evolut valve (Medtronic). 16,17 In contrast, obstruction of the coronary ostia reportedly rarely occurs with aortic ViV over a Magna valve, in which the leaflets are mounted internally. Previous reports also state that it is possible to fracture the sewing cuff of the Magna valve with the high-pressure balloon to accept a 1-mm larger transcatheter heart valve than the labeled valve size, ex vivo. 18 Therefore, it is reasonable to suggest the Magna valve for patients who are likely to

Replacement Valve Choice in Japanese Patients 2775 need a second valve replacement surgery. This study is limited by its retrospective design. In addition, prosthetic valve selection (Trifecta vs. Magna) was not randomized, but instead was determined by individual surgeons who implanted the best-matched valve prosthesis for each patient. Selection bias may be minimal because there was no significant difference in patient background and characteristics between the 2 groups. Postoperative follow-up periods also significantly differed between the 2 groups, potentially introducing analytical bias. However, the patients background and characteristics and the surgical procedures, including prosthesis size, were almost identical between the 2 groups. In addition, we used appropriate statistical methods, such as the validated statistical linear mixed model, to eliminate potential bias related to different follow-up periods. Conclusions In conclusion, post-avr clinical outcomes, including LVM regression and patient prosthesis mismatch, did not differ significantly between the Trifecta and Magna valves. Although hemodynamic performance of the valve prosthesis was greater for the Trifecta valve at least until 1-year after AVR, this difference diminished gradually over time. Acknowledgment The authors thank Jane Charbonneau (Edanz Group; www. edanzediting.com/ac) for the English language editing of a draft of this manuscript. Sources of Funding This work was not supported by a specific grant from any funding agency in the public, commercial, or not-for-profit sectors. None declared. Conflict of Interest References 1. Kaneko T, Cohn LH, Aranki SF. Tissue valve is the preferred option for patients aged 60 and older. Circulation 2013; 128: 1365 1371. 2. Nakano K, Hirahara N, Motomura N, Miyata H, Takamoto S. Current status of cardiovascular surgery in Japan, 2013 and 2014: A report based on the Japan Cardiovascular Surgery Database. 4. Valvular heart surgery. Gen Thorac Cardiovasc Surg 2017; 66: 13 18. 3. Gozdek M, Raffa GM, Suwalski P, Kolodziejczak M, Anisimowicz L, Kubica J, et al. Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: Systematic review and meta-analysis. Eur J Cardiothorac Surg 2017; 53: 495 504. 4. Dumesnil JG, Pibarot P. Prosthesis-patient mismatch: An update. Curr Cardiol Rep 2011; 13: 250 257. 5. Sakamoto Y, Hashimoto K. Update on aortic valve prosthesispatient mismatch in Japan. Gen Thorac Cardiovasc Surg 2013; 61: 669 675. 6. Akins CW, Miller DC, Turina MI, Kouchoukos NT, Blackstone EH, Grunkemeier GL, et al. Guidelines for reporting mortality and morbidity after cardiac valve interventions. J Thorac Cardiovasc Surg 2008; 135: 732 738. 7. Bonow RO, Brown AS, Gillam LD, Kapadia SR, Kavinsky CJ, Lindman BR, et al. ACC/AATS/AHA/ASE/EACTS/HVS/SCA/ SCAI/SCCT/SCMR/STS 2017 Appropriate Use Criteria for the Treatment of Patients With Severe Aortic Stenosis: A report of the American College of Cardiology Appropriate Use Criteria Task Force, American Association for Thoracic Surgery, American Heart Association, American Society of Echocardiography, European Association for Cardio-Thoracic Surgery, Heart Valve Society, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. J Am Soc Echocardiogr 2018; 31: 117 147. 8. Haude M. Management of valvular heart disease: ESC/EACTS guidelines 2017. Herz 2017; 42: 715 720 (in German). 9. Ribeiro HB, Rodes-Cabau J, Blanke P, Leipsic J, Kwan Park J, Bapat V, et al. Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: Insights from the VIVID registry. Eur Heart J 2017; 39: 687 695. 10. Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA, et al. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: A report from the American Society of Echocardiography s Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography. J Am Soc Echocardiogr 2009; 22: 975 1014. 11. Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: Definition, clinical impact, and prevention. Heart 2006; 92: 1022 1029. 12. Hunt SA, Abraham WT, Chin MH, Feldman AM, Francis GS, Ganiats TG, et al. 2009 Focused update incorporated into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines developed in collaboration with the International Society for Heart and Lung Transplantation. J Am Coll Cardiol 2009; 53: e1 e90. 13. Nashef SA, Roques F, Sharples LD, Nilsson J, Smith C, Goldstone AR, et al. EuroSCORE II. Eur J Cardiothorac Surg 2012; 41: 734 744. 14. Goldman S, Cheung A, Bavaria JE, Petracek MR, Groh MA, Schaff HV. Midterm, multicenter clinical and hemodynamic results for the Trifecta aortic pericardial valve. J Thorac Cardiovasc Surg 2017; 153: 561 569.e562. 15. Stock S, Scharfschwerdt M, Meyer-Saraei R, Richardt D, Charitos EI, Sievers HH, et al. Does undersizing of transcatheter aortic valve bioprostheses during valve-in-valve implantation avoid coronary obstruction?: An in vitro study. Thorac Cardiovasc Surg 2017; 65: 218 224. 16. Haussig S, Schuler G, Linke A. Treatment of a failing St. Jude Medical Trifecta by Medtronic Corevalve Evolut valve-in-valve implantation. JACC Cardiovasc Interv 2014; 7: e81 e82. 17. Kim WK, Kempfert J, Walther T, Mollmann H. Transfemoral valve-in-valve implantation of a St. Jude Medical Portico in a failing Trifecta bioprosthesis: A case report. Clin Res Cardiol 2015; 104: 363 365. 18. Allen KB, Chhatriwalla AK, Cohen DJ, Saxon JT, Aggarwal S, Hart A, et al. Bioprosthetic valve fracture to facilitate transcatheter valve-in-valve implantation. Ann Thorac Surg 2017; 104: 1501 1508.