The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

Similar documents
AXS Catalyst Distal Access Catheter

Directions For Use. All directions should be read before use

Advanced Innovation for Exceptional Performance

RECOMMENDED INSTRUCTIONS FOR USE

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

ER REBOA Catheter. Instructions for Use

Directions For Use. All directions should be read before use. Page 1 of 8

PTA Balloon Dilatation Catheter

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Balloon in Balloon (BIB )

PTA Balloon Dilatation Catheter

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

LeMaitre Embolectomy Catheter

PTCA Dilatation Catheter. Instructions for Use

Cardiva Catalyst III INSTRUCTIONS FOR USE

Z-MED II BALLOON AORTIC AND PULMONIC VALVULOPLASTY CATHETER. Instructions for Use

PTCA Dilatation Catheter. Instructions for Use

Balloon in Balloon (BIB )

Figure 1: Revolution TM Peripheral Atherectomy System Diagram. Table 1: Revolution TM Peripheral Atherectomy System Specifications Minimum Burr

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

Single Pass MCA Revascularization with Trevo

Instructions for Use 1

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

System.

Lutonix AV Clinical Trial

Pruitt Irrigation Occlusion Catheter. English Instructions for Use. Pruitt Irrigation Occlusion Catheter

The Role of LUTONIX 035 DCB in AV Fistula Dysfunction Management in our Practice

Instructions for Use Reprocessed 3D Diagnostic Ultrasound Catheters

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

LUTONIX DCB in BTK Update on the BTK clinical program & single center experience

TYSHAK DILATATION CATHETER. Instructions for Use CAUTION: Federal (USA) Law restricts this device to sale by or on the order of a physician.

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

INSTRUCTIONS FOR USE

MICHAEL R. JAFF, DO MASSACHUSETTS, UNITED STATES. Medtronic Further. Together

DISRUPT PAD. (( Data Summary )) DISRUPT PAD Data Summary SPL Rev. B 2016 Shockwave Medical Inc. All rights reserved.

Patient Information. Peripheral Arterial Disease and the Lutonix 035 Balloon. Advancing Lives and the Delivery of Health Care

Peel-Apart Percutaneous Introducer Kits for

Ruby Coil. Large Volume Detachable Coils

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

Emerge. PTCA Dilatation Catheter ONLY. monorail. over-the-wire

BTK Case Studies Joseph Cardenas, MD AZ Heart & Vascular, Yuma, AZ

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING

eptfe Vascular Graft Instructions for Use

Understanding aneurysms and flow diversion treatment

Innovation by design. Technology that sets a new standard

COIL SYSTEM ORDERING INFORMATION

CLARIVEIN INFUSION CATHETER

ASAHI Corsair INSTRUCTIONS FOR USE

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

AXIOS Stent and Delivery System

Pocket Reference Guide For (CTO) Technologies

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

Pruitt-Inahara Carotid Shunt

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

INSTRUCTIONS FOR USE FOR:

Instructions for Use Reprocessed Arthroscopic Shavers

Talent Abdominal Stent Graft

Azur CX 35 Peripheral Coil System (Detachable) Instructions for Use

Stellarex Drug-coated 0.035" Angioplasty Balloon. Featuring EnduraCoat Technology. The Clear DCB Choice

2019 ABBOTT REIMBURSEMENT GUIDE CMS Physician Fee Schedule

Finally, the Control You Need to Deliver Accurate Treatment

PERFORMANCE YOU CAN TRUST. EverFlex Self-expanding Peripheral Stent with Entrust Delivery System

Express LD Iliac. Premounted Stent System ONLY. over-the-wire

Chronic Total Occlusion (CTO) Technologies

ULTRA ICE PLUS ULTRASOUND IMAGING CATHETER. Know where you are. See what you want to avoid.

Allium Trans-hepatic Biliary Stent (BIS)

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Complex ilio-caval revascularization in chronic venous obstruction with the Venovo Stent. Michael K. W. Lichtenberg MD, FESC

CTO Product Portfolio

Wolverine Coronary Cutting Balloon

Coronary angiography and PCI

Turbo-Power. Laser atherectomy catheter. The standard. for ISR

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

Sustained Release. Superior Results.

Peritoneal Drainage System

CP STENT. Large Diameter, Balloon Expandable Stent

Advisor FL Circular Mapping Catheter, Sensor Enabled D-AVSE-D10-F20, D-AVSE-DF10-F20, D-AVSE-D10-F15, D-AVSE-DF10-F15. Instructions for Use

Why and how to prep the vessel

Device Preparation (all steps to be performed per standard interventional technique)

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

INNOVATIVE TWO-IN- ONE FUNCTIONALITY. ARROW GPSCATH FEATURING VISIOVALVE Navigate with confidence

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels

First experience with DCB for treatment of dialysis access stenosis The Greek experience

How to manage TAVI related vascular complications. Paul TL Chiam MBBS, FRCP, FESC, FACC, FSCAI

Single Use Curlew TM Multiple Biopsy Forceps

Access More Patients. Customize Each Seal.

MULTILAYER FLOW MODULATOR (MFM ) FOR PERIPHERAL ANEURYSMS TREATMENT (LOWER LIMBS, VISCERALS AND SUBCLAVIAN)

Angioplasty remains the most common method

Instructions for Use Reprocessed Diagnostic Electrophysiology Catheters

Instructions for Use ANGIOGUARD XP Emboli Capture Guidewire System

Instruction for Use of 3-stage Dilation Balloon Catheter JS-CE-SM-08-01, A/0

Neuroform EZ Stent System

CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN.

Transcription:

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device Instructions for Use Contents Contains one (1) SplitWire device. Sterile. Sterilized with ethylene oxide gas. Radiopaque. For single use only. Do not autoclave. Caution: Federal (USA) law restricts this device to the sale by, or on the order of, a physician. I. Device Description SplitWire without PTA Balloon SplitWire with PTA Balloon The SplitWire Percutaneous Transluminal Angioplasty Scoring Device is designed to facilitate the dilatation of stenoses. The SplitWire device is intended to be used with a percutaneous transluminal angioplasty balloon catheter. The SplitWire device consists of two (2) wires that are joined at the distal end. The larger wire (scoring wire) has a triangular profile near the distal end, that when the balloon is inflated applies pressure to the lesion being treated. The smaller wire (tracking wire) is used to position the PTA balloon catheter in the proper location adjacent to the lesion. There are two (2) radiopaque markers bands on the tracking wire that indicate the location for the PTA balloon catheter placement. The distal section of the SplitWire is designed to be atraumatic with a radiopaque coil for visibility. The distal section is coated with a soft polymer. Page 1 of 5

II. Indications for Use The SplitWire Percutaneous Transluminal Angioplasty Scoring device is indicated for the use with percutaneous transluminal angioplasty (PTA) catheters to facilitate dilation of stenoses in the iliac, femoral, ilio-femoral, popliteal, infra-popliteal, and renal arteries and treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. III. Contraindications Where there is the inability to cross the target lesions with a guidewire For use in the coronary or neuro vasculature IV. Warnings 1. Contents supplied sterile using ethylene oxide (EO) process. Do not use if sterile barrier is damaged. 2. For single product and patient use only. Do not re-use, re-process or re-sterilize. Reuse, reprocessing or re-sterilization may compromise the structural integrity of the device and/or lead to device failure, which in turn may result in patient injury, illness or death. Reuse, reprocessing or re-sterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient. Accordingly, the Manufacturer or its Distributors will not be responsible for any direct or consequential damages or expenses resulting from reuse, reprocessing or re-sterilization of the SplitWire device. 3. After use, this product may be a potential biohazard. Handle and dispose of in accordance with accepted medical practice and with applicable local, state and federal laws and regulations. 4. The SplitWire device has not been tested in stents and is not recommended for use in stents. The SplitWire device is not indicated to treat in-stent restenosis. Complications may result from use of the SplitWire device in stents. V. Precautions 1. Carefully inspect the device prior to use. Do not use if damaged. 2. The device should only be used by a physician trained in the performance of percutaneous transluminal angioplasty. 3. Store in a cool, dark, dry place. 4. Use prior to the Use By date. 5. Fluoroscopic guidance should be used when the SplitWire device is in the vasculature. 6. If strong resistance is met during any stage of the procedure, discontinue the procedure and determine the cause before proceeding. VI. Potential Complications Page 2 of 5

The complications that may result from a peripheral balloon dilation procedure include: Additional intervention Allergic reaction to drugs and contrast media Aneurysms and Pseudo aneurysms Arrhythmias Arterial spasm Arteriovenous fistula Embolization Hematoma Hemorrhage, including bleeding at puncture site Hypotension / Hypertension Inflammation Occlusion Pain or tenderness Pneumothorax or hemothorax Re-stenosis of the dilated artery Sepsis / Infection Shock Short term hemodynamic deterioration Stroke Thrombosis Vessel dissection, perforation, rupture, or spasm VII. Recommended Procedure The SplitWire device is used to augment a PTA balloon catheter during a PTA procedure. NOTE: The introducer sheath size may need to be increased to accommodate the overall diameter of the PTA balloon catheter and SplitWire device when used together. Refer to the PTA balloon catheter instructions for use for information on the use of the PTA balloon catheter. 1. Flush SplitWire device while still contained in packaging hoop. 2. While PTA balloon catheter is still at the treatment / lesion location, advance the entire device (both wires) through the guidewire lumen of the PTA balloon catheter (Figure 1) until the radiopaque tip of the SplitWire is distal to the end of the PTA balloon catheter (Figure 2). Page 3 of 5

Figure 1. Advance SplitWire Device through guidewire lumen of PTA Balloon Catheter Figure2. SplitWire and PTA Balloon Catheter at the treatment location 3. If not already done, deflate the PTA balloon catheter according to its instructions for use. 4. Remove the PTA balloon dilation catheter while leaving the SplitWire device in place (Figure 3). Figure 3. Remove the PTA Balloon Catheter leaving the SplitWire device at treatment location 5. Re-advance the PTA balloon catheter over only the tracking wire of the SplitWire device leaving the larger wire external to the outer diameter of the PTA balloon catheter (Figure 4). Figure 4. Advance the PTA Balloon Catheter over the tracking wire of the SplitWire Device Page 4 of 5

6. Advance the PTA balloon catheter until resistance is felt and the PTA balloon catheter is fully advanced near the distal RO band of the SplitWire device. Confirm the RO bands of the balloon catheter are inside the RO bands of the SplitWire device (Figure 5). Figure 5. Proper placement of PTA Balloon Catheter and SplitWire Device prior to treatment 7. Inflate the PTA balloon catheter according to its instructions for use. 8. After treatment deflate balloon and remove both devices from vasculature. VIII. Disclaimer of Warranty and Limitation of Remedy There is no express or implied warranty, including without limitation any implied warranty of merchantability or fitness for a particular purpose, on product(s) described in this publication. Under no circumstances shall the Manufacturer or its Distributor be liable for any direct, incidental or consequential damages other than as expressly provided by specific law. No person has the authority to bind the Manufacturer or its Distributor to any representation or warranty except as specifically set forth herein. Descriptions or specifications in the manufacturer and distributor s printed matter, including this publication, are meant solely to generally describe the product at the time of manufacture and do not constitute any express warranties. Manufacturer and Distributor will not be responsible for any direct, incidental or consequential damages resulting from reuse of the product. X-2024-0017-00 Rev. D Page 5 of 5