SYNTHECEL Dura Repair. Assurance and Versatility for Dura Reconstruction.

Similar documents
SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

CRANIAL RECONSTRUCTION SOLUTIONS

low ProfIle neuro PlaTIng system

RAPIDSORB RAPID ReSORBABLe CRANIAL CLAMP

Lyoplant Onlay. Adding another layer of confidence to every procedure. Aesculap Neurosurgery

Low Profile Neuro Plating System. Surgical Technique

matrixwave tm mmf expand your possibilities A novel system that expands and compresses to achieve maxillomandibular fixation

Neurosurgery is complex. DuraGen is the simple choice.

Technique Guide. SynPOR Porous Polyethylene Implants. For craniofacial and orbital augmentation and reconstruction.

CONFORM FlEX. Demineralized cancellous bone

Mini External Fixator

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

CONFORM SHEET. Demineralized cancellous bone

DuraMatrix Collagen Dura Substitute Membrane. Manufactured by: Collagen Matrix, Inc., Franklin Lakes, New Jersey

orthodontic Bone anchor (oba) SYStem

Titanium Wire With Barb and Needle

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

INSTRUCTIONS FOR USE FOR:

3.5 mm Clavicle Hook Plates

Technique Guide. SynPOR HD Ocular Spheres. For augmentation or reconstruction.

Application Guide for Full-Thickness Wounds

DuraMatrix portfolio. Restore with confidence

P e r i - G u a r d I N S T R U C C I O N E S D E U S O M O D E D E M P L O I... 6 I S T R U Z I O N I P E R L U S O

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

SHOULDER EXTRACTION INSTRUMENTS

DISTRACTION PRODUCT OVERVIEW. For a wide variety of facial applications

SPINE BIOMATERIALS Crop Bleed

Technique Guide. Cranial Clamps with Application Instrument. Quick and stable fixation of cranial bone flaps following a craniotomy.

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

RAPIDSORB RAPID RESORBABLE FIXATION SYSTEM. A new resorbable approach to Alveolar bone augmentation

HeliMEND Advanced. Absorbable Collagen Membrane. Instructions for Use

Instructions for Use. Wright Medical Technology 1023 Cherry Road Memphis, TN USA

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

Distal Radius Sterile Kit. Optimization And Efficiency You Can Rely On

got you covered. Codman s The global leader in neurosurgery is your one-stop, comprehensive source for proven, market-leading dural repair solutions.

V a s c u - G u a r d

NovoSorb BTM. A unique synthetic biodegradable wound scaffold. Regenerating tissue. Changing lives.

MatrixNEURO Cranial Plating System

Trochanter Stabilization Plate for DHS Implants

Restoration not just repair

eptfe Vascular Graft Instructions for Use

SYNPOR HD FACIAL SHAPE SYSTEM SURGICAL TECHNIQUE. For the augmentation or reconstruction of the craniomaxillofacial skeleton

For Distal Femur Fractures. 95º Condylar Plate. Quick Reference Chart

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

POSTERIOR LUMBAR FUSION SURGICAL TECHNIQUE USING A BONE VOID FILLER. Magnifuse. Bone Graft

The Synthetic Self-Adhesive Barrier to Cerebrospinal Fluid Leaks

SFX Cross Connector System. Surgical Technique Guide

BACTISEAL Endoscopic Ventricular Catheter (REF & )

Drillable Fast Set Putty

Dentoalveolar Bone Fixation System. Bone fixation sets for the office.

RECLAIM REVISION HIP SYSTEM

RAPIDSORB RAPID RESORBABLE FIxATION SySTEm

3.5 mm Locking Attachment Plate

Device Preparation (all steps to be performed per standard interventional technique)

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

Single Use Curlew TM Multiple Biopsy Forceps

Calcium Phosphate Bone Void Filler TECHNIQUE GUIDE

T-PAL Spacer System. Transforaminal posterior atraumatic lumbar spacer system.

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

PRODUCT CATALOG SPEED SPEEDSHIFT SPEEDARC SPEEDTITAN SPEEDTRIAD HAMMERLOCK 2 BME ELITE

Case Study. TRAM Flap Reconstruction with an Associated Complication. Repair using DermaMatrix Acellular Dermis.

3.5 mm LCP Extra-articular Distal Humerus Plate

Integra Flowable Wound Matrix

Control. Control Through VISCOSITY Control Through DELIVERY Control Through SIMPLICITY

Trephine System. Principle-based anterior lumbar interbody fusion.

DermaSpan Acellular Dermal Matrix. Reinforcement of Ruptured Posterior Tibial Tendon Repair. Surgical Protocol by Charles Zelen, DPM, FACFAS

Large Distractor Femur

Bone Preservation Stem

Doc no: IFU/CC Issue date: Rev no: 04 Rev date:

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Cardiva Catalyst III INSTRUCTIONS FOR USE

HP KNEE EXTRACTION Instrumentation. Product Overview

Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Procedures.

PRO-DENSE BONE GRAFT SUBSTITUTE

Versatile grafting Solutions

ALLOPURE. Bicortical Allograft Wedges Specific for Evans and Cotton Osteotomies SURGICAL TECHNIQUE

2.0 mm Mandible Locking Plate System

3.5 mm LCP Olecranon Plates

The following languages are included in this packet:

Advisor FL Circular Mapping Catheter, Sensor Enabled D-AVSE-D10-F20, D-AVSE-DF10-F20, D-AVSE-D10-F15, D-AVSE-DF10-F15. Instructions for Use

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

Tissue Sparing. DEsign Rationale

Variable Angle LCP Locking Technology

Breast Reconstruction Postmastectomy. Using DermaMatrix Acellular Dermis in breast reconstruction with tissue expander.

VERSALOK SURGICAL TECHNIQUE FOR ROTATOR CUFF REPAIR SURGICAL TECHNIQUE VERSATILITY STRENGTH SPEED

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

T-PLIF Spacer. An allograft spacer for transforaminal posterior lumbar interbody fusion.

VIPER PRIME System Cadaver Time Study

Technique Guide KISSloc Suture System

READ BEFORE USING. Contents:

ÆLITE Composites. Bisco. Instructions for Use. Light- Cured. U.S. Patent: 6,709,271

The Fusion of. Strength, Design. Performance. and

DMF Page 63. Description

COR. Precision Targeting Cartilage Repair System. Arthroscopic Technique for Repair of Osteochondral Defects

AXS Catalyst Distal Access Catheter

Transcription:

SYNTHECEL Dura Repair Assurance and Versatility for Dura Reconstruction.

SYNTHECEL Dura Repair is an assured and versatile solution for your dura reconstruction needs. Clinically proven One product choice for excellent onlay or suture performance Superior handling No adhesions * Non-animal derived, no risk of transmissible diseases Non-pyrogenic MR safe SYNTHECEL Dura Repair from clinical study. Courtesy of Barrow Neurosurgical Associates, Ltd. Conformable SYNTHECEL Dura Repair thickness is similar to human dura 1,2 and conforms to the brain. Suturable SYNTHECEL Dura Repair is excellent in sutureability. 3 *observed in clinical study. 1. Ontano SE, et al. Mechanical behavior of human dura mater. Transcripts from the BED Bioeng Con- ASME 29:329-330, 1995. 2. Sacks MS, et al. Local mechanical anisotropy in human cranial dura mater allografts. J Biomech Eng 120:541-544, 1998. 3. Rosen, Charles L., et al. Results of the Prospective, Randomized, Multicenter Clinical Trial Evaluating a Biosynthesized Cellulose Graft for Repair of Dural Defects. Neurosurgery. 2011 Nov;69(5):1093-103; discussion 1103-4. Control group: Duraform Dural Graft implant (15 units), Duragen II Dural Regeneration Matrix (8 units), Duragen Dural Graft Matrix (10 units), Durepair Regeneration Matrix (2 units), Duragen Plus (1 unit), and Preclude Dura Substitute (1 unit).

SYNTHECEL Dura Repair performance was demonstrated in a prospective, randomized, controlled study *. Superior Seal Quality Superior Strength No adhesions reported Superior Seal Quality SYNTHECEL Dura Repair demonstrated statistically significant seal quality. Superior Strength SYNTHECEL Dura Repair demonstrated statistically significant strength. *Rosen, Charles L., et al. Results of the Prospective, Randomized, Multicenter Clinical Trial Evaluating a Biosynthesized Cellulose Graft for Repair of Dural Defects. Neurosurgery. 2011 Nov;69(5):1093-103; discussion 1103-4. Control group: Duraform Dural Graft implant (15 units), Duragen II Dural Regeneration Matrix (8 units), Duragen Dural Graft Matrix (10 units), Durepair Regeneration Matrix (2 units), Duragen Plus (1 unit), and Preclude Dura Substitute (1 unit).

Naturally Formed, Biosynthesized Cellulose. SYNTHECEL Dura Repair is composed of biosynthesized cellulose and water. Layers, biosynthesized cellulose Interconnected, cellulose fibers Naturally formed by Gluconacetobacter xylinus

INSTRUCTIONS FOR USE Package: Provided sterile and must not be reused or re-sterilized. Do not use past expiration date, if package has been compromised or if the implant is dry. Storage: Store at room temperature, must not be frozen (5 C/41 F) or exposed to temperatures above 40 C/104 F. If there is a in the temperature indicator window, product is ok to use. If there is an X in the temperature indicator window, do not use the product. Application: Step 1: Open carton and outer pouch. Pass sterile, inner pouch onto the sterile field. Rinse surgical gloves to remove glove powder prior to handling the implant. Implant is packaged wet and ready to use. Protective plastic sheeting prevents implant from drying out. No rinsing or soaking for re-hydration is required. Step 2: When ready to use, open inner pouch and remove implant using aseptic technique. Immediately prior to use, remove and discard the protective plastic sheeting from both sides of the implant using aseptic technique. Do not allow implant to dry out prior to implantation. Step 3: Apply implant with or without sutures. Trim and size the implant to completely cover the defect with an overlap of sufficient size to allow sutures (if desired) to be placed along the margin of the implant 3 to 4 mm from the edge. Tensionless atraumatic sutures may be used if desired. Use non-absorbable, smallest appropriate diameter suture with a tapered (non- cutting) needle of appropriate size to anchor the material. Final suture selection should be determined by surgeon preference and the nature of the dural repair. A watertight closure should be achieved to minimize the possibility of CSF leakage. Ensure the edges of the implant are not folded. Allow sufficient size so that suturing does not place implant or surrounding dura under tension. Implant can be repositioned if required prior to suturing. Use caution when repositioning the implant to avoid tears. Step 4: Close remaining cranial layers to preference and clinical need. Discard all unused pieces of SYNTHECEL Dura Repair. Please refer to package insert for complete indications, contraindications, warnings and precautions.

SYNTHECEL Dura Repair A Size for all your Clinical Needs. Product Code Size Units Per A SC.400.006.01S 1 in x 1 in (2.5 cm x 2.5 cm) 1 B SC.400.019.01S 1 in x 3 in (2.5 cm x 7.5 cm) 1 C SC.400.025.01S 2 in x 2 in (5.0 cm x 5.0 cm) 1 D SC.400.056.01S 3 in x 3 in (7.5 cm x 7.5 cm) 1 E SC.400.120.01S 4 in x 5 in (10.0 cm x 12.0 cm) 1 Images shown are to scale in inches. Products are sold sterile. B 1 (2.5 cm) 3 (7.5 cm) E D C A 1 (2.5 cm) 2 (5.0 cm) 1 (2.5 cm) 3 (7.5 cm) 4 (10.0 cm) 2 (5.0 cm) 3 (7.5 cm) 5 (12.0 cm) Indications : SYNTHECEL Dura Repair is intended for use as a dura replacement for the repair of dura mater in adults. Contraindications : SYNTHECEL Dura Repair must not be implanted in patients who have known allergy or sensitivity to the implant materials (cellulose). WARNINGS : The safety and effectiveness of SYNTHECEL Dura Repair has not been studied in: Patients that are less than 18 years of age. Patients who also required use of dural adhesive or sealant. Patients who had systemic infection (e.g. urinary tract infection, active pneumonia) or evidence of any surgical site infection, fever > 38.3 C (101 F), positive blood culture and/or a positive chest x-ray for acute infectious process. Patients who were acute cranial trauma surgical cases. Patients who had chemotherapy and/or radiation treatment within 12 weeks prior to surgery, or had chemotherapy and/or radiation treatment planned 10 weeks post surgery. Patients who had compromised immune system or autoimmune disease. PRECAUTIONS : SYNTHECEL Dura Repair is provided sterile and should not be resterilized. Do not use if packaging or seal has been damaged or opened. SYNTHECEL Dura Repair should be stored at room temperature; must not be frozen (5 C/41 F) or exposed to temperatures above 40 C/104 F. SYNTHECEL Dura Repair is intended for single patient use only. Discard opened or unused product. Immediately prior to use: remove and discard the protective plastic sheeting from both sides of the device using aseptic technique. Do not allow implant to dry out prior to implantation. Tension should be avoided if suturing the SYNTHECEL Dura Repair. Ensure the edges of the implant are not folded. SYNTHECEL Dura Repair should be used with caution in restricted areas of the skull, (e.g., posterior fossa) due to the potential for local mass effect. Manufactured in the United States by: Synthes, Inc 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 www.depuysynthes.com Limited Warranty and Disclaimer: DePuy Synthes CMF products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. WARNING: In the USA, this product has labelling limitations. See package insert for complete information. Rx Only Not available for sale in Canada. DePuy Synthes CMF, a division of DOI 2014. All rights reserved. DSUS/CMF/0314/0011(1)