AAPM Annual Meeting. ACR Accreditation Update in CT

Similar documents
Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

CT Quality Control Manual FAQs

BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

Update on MQSA and Mammography Accreditation

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

HISTORY OF MQSA AND ACR

Prepublication Requirements

ACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program

Overview. ACR Accreditation Update in Mammography. New ACR Activities. Requirements Today. What s New For Tomorrow. ACR: Recognized by FDA and CMS

ACR MRI Accreditation: Medical Physicist Role in the Application Process

MRI FAQs. After reading these documents and checking your protocols, you can apply online here:

ACR Accreditation Toolkit for Validation Site Surveys

Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

Overview. ACR Update on FFDM Accreditation. New ACR Activities. QC Today. QC Tomorrow. ACR Breast Imaging Centers of Excellence BICOE

The American College of Radiology Breast Ultrasound Accreditation Program: Frequently Asked Questions (Revised: July 31, 2017)

Low Dose CT Lung Screening: What is Technically Required?

History of MQSA ACR creates testing procedures Oct Mammography Quality Standards Act Dec 1993 Interim Regulations Oct All mammog

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

CT Low Dose Lung Cancer Screening. Part I. Journey to LDCT LCS Program

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Mammography Quality Control: A Refresher

MR QA/QC for MRgRT. Rick Layman, PhD, DABR Department of Radiology July 13, 2015

ACR Accreditation Update in MRI

Dianna Cody, PhD, DABR, FAAPM Professor & Clinical Operations Director Imaging Physics U.T. M.D. Anderson Cancer Center Houston, TX

NONE. Disclosures. Accreditation Update

354 Korean J Radiol 9(4), August 2008

The American College of Radiology Digital Mammography QC Manual: Frequently Asked Questions (Revised 12/12/2018; new and updated items in red)

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

Re: PSM of the National Voluntary Consensus Standard for Patient Safety Measures, 2 nd Report

MQSA Physicist Qualifications. Jon J. Erickson, Ph.D., DABR

American College of Radiology CT Accreditation Program. Testing Instructions

Q. Where can I find out if my state currently requires stereotactic breast biopsy accreditation?

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Multicenter Trial, Phase I Assessment of 2-D FFDM Versus Combo of 2-D and 3-D Tomosynthesis in Breast Cancer Screening

Nuts and Bolts of MRI Physics Tests or Selling Preparation H. Robert A. Bell, PhD. Learning Objectives

icat Precise Policy and Procedure Manual

Ultrasound Accreditation Program Requirements

Medical Diagnostic Imaging

ACR Breast MRI Accreditation Program - DRAFT

NJ CBCT Regulation FAQ & Assistance

Hands-On Ultrasound Physics and Quality Control Workshop. Outline

Update on the ACR FFDM QC Manual

Introduction and Background

Routine Quality Assurance Cookbook

Imaging Rotation. University of Michigan Department of Radiation Oncology Division of Radiation Physics. Resident:

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

IMAGE GENTLY HOW CAN YOU HELP?

CT Radiation Risks and Dose Reduction

ACCREDITATION CASE REVIEW 2: US AND US-GUIDED BIOPSY CRITERIA

Computed tomography Acceptance testing and dose measurements

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Debbie Childs RDMS, RVT Sonographer Murphy Medical Center Murphy, NC

Hong Kong College of Radiologists Mammography Statement

Steven Tate Nicholas

Breakout Session 1: Image Acquisition

CT Head Dose Reduction Using Spiral Scanning Protocol

State of the art and future development for standardized estimation of organ doses in CT

Managing Radiation Risk in Pediatric CT Imaging

Lung Cancer Screening: Current Status

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011

MAMMOGRAPHY QC: MORE THAN PHANTOM IMAGES. Stephanie Schofield RTR QC Technologist Nova Scotia Health Authority

Fetal Dose Calculations and Impact on Patient Care

Highmark Privileging Application. 1. Complete this application if you provide any diagnostic

The American College of Radiology Breast MRI Accreditation Program: Frequently Asked Questions (Updated: October 4, 2017)

Please follow all instructions carefully.

Quality assurance in external radiotherapy

Compliance with TJC Guidelines on CT Clinical Practice

Hands-on. Physics Workshop. 2-day Workshop June 1-2, 2018 Ann Arbor, MI. Program Director: Brian Fowlkes, PhD

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Ultrasound Accreditation and Regulatory Compliance from A to Z

Alfred Health's CT quality control program

Dose Metrics in the Patient Report: Myopic or Foresighted?

Practice Analysis and Content Specifications. for Registered Radiologist Assistant

9/3/2015. New Mammographic Modality Training. Mammographer. Qualified Radiologic Technologist. Tomosynthesis Training

Hong Kong Association of Medical Physics. Guide to Candidates

EORTC Member Facility Questionnaire

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Maintaining a quality mammography facility: Overview of ACR and MQSA Requirements and Update on BI-RADS 5 TH Edition

Outcomes in the NLST. Health system infrastructure needs to implement screening

Steven LaFontaine Position: Certification: State of California Approved Physicist List: ACR Accreditation Programs Qualified For: Education:

Outline. NCRP Scientific Committee 6-2

FDG-18 PET/CT - radiation dose and dose-reduction strategy

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Establishing the quality management baseline in the use of computed tomography machines in Kenya

MPPG 1 Evaluation and quality assurance of x-ray based image guided radiotherapy systems

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

The New Jersey Radiographic Quality Assurance Program at 5 Years

RPR 48B. APPLICATION TO USE DIAGNOSTIC EXTERNAL RADIATION IN HUMAN RESEARCH STUDIES

Mammography. What is Mammography? What are some common uses of the procedure?

Breast Tomosynthesis. What is breast tomosynthesis?

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Implementation of a New Tomosynthesis Program: A Physicists Perspective

The AAO- HNS s position statement on Point- of- Care Imaging in Otolaryngology states that the AAO- HNS,

CASE STUDIES. Population. Compression

Jodi Daves 1819 Overlook Terrace Louisville, KY US

The Practice Standards for Medical Imaging and Radiation Therapy. Sonography Practice Standards

Transcription:

AAPM Annual Meeting ACR Accreditation Updates in CT, Ultrasound, Mammography and MRI: ACR Accreditation Update in CT Michael McNitt-Gray, PhD, DABR, FAAPM Professor, Department of Radiological Sciences David Geffen School of Medicine at UCLA Chair, ACR CT Accreditation Program Physics Subcommittee

Learning Objective To understand the requirements of the ACR CT accreditation program, including updates to the QC manual, FAQ process and the newest program ACR Designated Lung Screening Center.

ACR CT Accreditation Program The CT Accreditation Program involves the acquisition of clinical and phantom images, dose measurements and the submission of scanning protocols.

What s New? The GOALS remain the same The CONTEXT has changed CTAP started as a VOLUNTARY program 1-1-12 : Medicare Part B REQ D accreditation by a CMMS approved body ACR CTAP was one of the approved bodies

What s New? In CA, State Law REQUIRED accreditation by one of the bodies recognized by CMS That clause went into effect July 1, 2013 Again, not REQUIRED to be ACR accredited, but it was one of the approved accrediting bodies.

What s New? The GOALS remain the same SOME aspects have changed A few highlights: Electronic Submission Requirements QC manual http://www.acr.org/quality-safety/accreditation/ct

What s New? ELECTRONIC SUBMISSION OPTION Submission can now be completely electronic (no film, no CDs) This includes forms, clinical images, phantom images and dosimetry spreadsheets Note that CD Submission is still available

What s New? Physics (Phantom Portion) testing is unchanged For each protocol being submitted: CT number accuracy Low-contrast resolution Image uniformity CTDI

What s New? Some values HAVE CHANGED

What s New? Some values HAVE CHANGED PEDS CNR values changed as well

What s New? QC Program New Requirements Effective Dec 1, 2013 all ACR CT accredited sites must maintain a documented quality control (QC) program and must comply with the min. frequencies of testing outlined in the manual

What s New? QC Manual CT QC manual was released 12-1-12 Updated August 2013 Available on ACR CTAP website http://www.acr.org/quality-safety/accreditation/ct

QC Manual Three main sections: Radiologist Section Technologist Section Medical Physicist Section

QC Manual Radiologist Section Definition of Quality Assurance Definition of Equipment Quality Control Responsibilities of the Radiologist Responsibilities of the Quality Control Tech. Responsibilities of Qualified Med Physicist

QC Manual Radiologist Section

QC Manual Technologist Section Technologist Daily Quality Control Technologist Weekly Quality Control Technologist Monthly Quality Control

QC Manual Technologist Section

QC Manual Physicist Section Annual Tests Protocol Review Scout Prescription and Alignment Light Accuracy Image Thickness Table Travel Accuracy Radiation Beam Width Low Contrast Performance

QC Manual Physicist Section Annual Tests (continued) Spatial Resolution CT Number Accuracy Artifact Evaluation CT number uniformity Dosimetry Gray Level Performance of CT Acquisition Display Monitors

QC Manual Physicist Section Each Test: Objective Frequency Equipment (ACR Phantom or Mfr Phantom) Test Procedure Data Interpretation and Analysis Precautions and Caveats Recommended Perform Criteria and Correct. Action Timeframe for Corrective Action

Frequently Asked Questions (FAQs) CTAP has used FAQs since the beginning FAQs for accreditation submissions *NEW* FAQs for QC manual as well Clarifications Scanner specific responses (often in conjunction with manufacturers) http://www.acr.org/~/media/acr/documents/accre ditation/ct/ct%20qc%20manual%20faq%2081 613%20Final.pdf

ACR Designated Lung Screening Center Announced Spring 2014 (> 1000 facilities already) Unit-specific All sites applying for this designation must: Have active ACR CT accreditation in chest module on designated unit(s). AND meet the requirements described in the application (yes, it costs $400 per facility) http://www.acr.org/quality-safety/lung-cancer- Screening-Center

ACR Designated Lung Screening Center Application: Site Information/Demographics, supervising physician and CT unit info Attestation form NOTE: No Phantom, No Clinical Images, No CTDI measurement spreadsheets (you re welcome!) The facility s lung cancer screening protocol in a clinical data form Fee http://www.acr.org/quality-safety/lung-cancer-screening-center

ACR Designated Lung Screening Center Attestation form Recommended Screening Population Personnel Qualifications interpreting physicians Medical physicists and radiologic technologists Follow up System structured reporting system Smoking Cessation CT Equipment Quality Control Imaging Protocol will be submitted (next slide) Attestation that ACR-STR Practice Parameter has been reviewed and will be followed http://www.acr.org/quality-safety/lung-cancer-screening-center

ACR Designated Lung Screening Center Imaging Protocol submission form

Conclusion Described: Req s of the ACR CT accreditation program Updates to the QC manual FAQ process Designated Lung Screening Center