FUNGAL PARTICULATE AIR SAMPLING

Similar documents
Indoor Air Quality Testing. Horry County Schools

DATE: May 23, TO: Tommy Ellington, Executive Director

1251 Weatherstone Ct. Reston,VA Mold Reduction Report

DATE: September 15, TO: Sarah Johnston, Director

FUNGAL (MOLD) TESTING RESULT REPORT* Cover Page

AIRBORNE FUNGAL STRUCTURE SAMPLE ANALYSIS Results reported as Structures per Cubic Meter of Air (structures/m 3 )

March 01, Re: Mold Sampling. Dear Mr. Jon Lewis,

MYCOLOGY REPORT. Report: / 3503 Wgaon Wheel, Wichita Falls, TX

Tape Lift and Swab Sampling of Items found at Glenwood Middle School Project #J15-876

A Healthy Home, LLC West Center Dr. Lakewood, CO

MOLD INSPECTION REPORT

SUBJECT: Administration Building - IAQ - Initial Contact report - Room 217, Hallway outside Room 217, Room 201, Room 225, Room 212

AIRBORNE MOLD SPORE ANALYSIS

Literature Building Mold Sampling Report

Analysis Report prepared for Quest Air

DATE: September 12, TO: Curtis Martin, Principal. SUBJECT: Tom Hicks ES - IAQ - Air Test Results - Nurses' Office, Main Admin Office

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

AladdinEnvironmentalLLC

DATE: April 21, TO: Lisa Moore, Executive Director

RE: Total Airborne Mould Spore Sampling Brookside Junior High 2239 Prospect Road, Hatchet Lake, NS

January 31, Mr. Mark LaFleur Director of Plant Operations Town of Needham 1330 Highland Avenue Needham, MA 02492

Environmental Assessment, Timothy Dwight Elementary School 1600 Redding Road, Fairfield, Connecticut

Occupational Health & Safety, Environmental Consultants Tel. (508) Tel. (800) Fax (508)

DATE: February 14, TO: Amy Acosta, Principal

M. A. CECIL & ASSOCIATES, INC Shannon Way, Port Republic, Maryland (301) INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH

RLB CIH, LLC. Final Report Microbial Contamination Sampling Taos Recreation Center Taos, New Mexico. March 9, 2007

Certificate of Mold Analysis

Air Sampling and Analysis for Mold in Hills Building UMass

Mastertech North Jersey

Certificate of Mold Analysis

test address: P R E PAR E D F OR : CalPro Inspection Group Phone Number: (800)

Certificate of Mold Analysis

STC Environmental Services Inc. Environmental Scientists and Engineers

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

Certificate of Mold Analysis (941) (941) SAMPLE REPORT

Certificate of Mold Analysis

Certificate of Mold Analysis

STC Environmental Services Inc. Environmental Scientists and Engineers

IAQ & MOLD AIR SAMPLING REPORT

EXPANDED FUNGAL REPORT

Certificate of Mold Analysis

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 01, 2013

No visible mold or water intrusion/damage was found on the day of testing.

EDLab. Re: 0 Any Street, # 100 Laboratory Analysis Report Work Authorization #

Certificate of Mold Analysis

C e r t i f i c a te o f m o ld Ana l y s i s

Certificate of Mold Analysis

MSES consultants, inc.

Certificate of Mold Analysis

Joseph T. Burkeson. Tuesday, November 19th, Total Professional Installation 1293 N. 60th St Tampa Fl, 33619

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Schneider Laboratories Global, Inc

C E R T I F I C A T E O F M O L D A N A L Y S I S

Based on our review, the following primary chemical constituents were identified for sampling: Acetone Toluene Xylenes Heptane

Certificate of Mold Analysis

Certificate of Mold Analysis

INDOOR AIR QUALITY CLEARANCE SAMPLING

C e r t i f i c a t e o f m o l d A n a l y s i s

Regulatory Compliance 245 Albany Avenue Thornwood, New York (914) Indoor Air Quality Screening At. Scarsdale UFSD

Certificate of Mold Analysis

CITY OF FORT PIERCE HOUSING REHABILATION PROJECT FOR 2802 AVENUE I BID NO ADDENDUM NO. 4

Certificate of Mold Analysis

SanAir Technologies Laboratory. Analysis Report. Hudson Valley Property Inspections, LLC

Schneider Laboratories Global, Inc

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 25, 2013

Legally Defensible Strategies for Mold Investigations

Submitted By: test test Submittal Date: 2/2/2017 1:47:53 PM Sample Date: 2/1/2017 Lab Job No.: Page 1 1

Regulatory Compliance 245 Albany Avenue Thornwood, New York (914) Indoor Air Quality Screening At. Scarsdale UFSD

AGENDA REQUEST. November 7, 2016

This test report contains the following four sections: Chain of Custody, Data Detail, Frequently Asked Questions, and Glossary.

Schneider Laboratories Global, Inc

MSES consultants, inc.

Certificate of Mold Analysis

Mycotech Biological, Inc.

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

CERTIFICATE OF MOLD ANALYSIS

Introduction: PCR Air Sampling: November 12, Carrie E Tompkins Elementary School PCR Fungi Study:

CERTIFICATE OF MOLD ANALYSIS PRISTINE INSPECTIONS & TESTING PHONE NUMBER: [

Certificate of Mold Analysis

This test report contains the following four sections: Chain of Custody, Data Detail, Frequently Asked Questions, and Glossary.

AladdinEnvironmental LLC

Certificate of Analysis

Cer tif ica te of mold Anal y sis

MSES consultants, inc.

EFFECT OF DIFFERENT AIR FLOW RATES ON THE COLLECTION OF ATMOSPHERIC MOLD SPORES OF DIFFERENT SIZES BY A SLIT IMPACTOR

PRO-TEC MOLD REPORT. Mold Evaluation

CONCENTRATIONS OF VIABLE FUNGAL SPORES ON PAPER DOCUMENTS

Laboratory Report. Prepared Exclusively For:

Analysis Report prepared for Mold-Spec

EMLab P&K MOLD REPORT Mr. Quality Control 1150 Bayhill Drive Suite 100 San Bruno, CA USA (650)

April 28, Town of Wilton Board of Education 395 Danbury Road Wilton, CT 06897

INDUSTRIAL HYGIENE ASSOCIATES, INC.

ECS Southeast, LLP. Report for Limited Indoor Air Quality Assessment

EMLab P&K MOLD REPORT Mr. Quality Control 1150 Bayhill Drive Suite 100 San Bruno, CA USA (650)

Certificate of Mold Analysis

Indoor Air Quality: Mold, Patients

Berman Inspection, LLC

Transcription:

November 19, 2016 Chuck Doan Yakima School District #7 104 N 4th Avenue Yakima, WA 98902 Via email: Regarding: doan.chuck@yakimaschools.org Fungal Sample Results Blue Wall Room 509 and Room 617 Eisenhower High School Yakima, Washington PBS Project: 64361.001 Dear Mr. Doan: On November 18, 2016, PBS Engineering and Environmental Inc. (PBS) performed air sampling for fungal particulate matter in Room 509 and Room 617 at Eisenhower High School in Yakima, Washington. Additional samples were collected outside these two rooms and outside the building for comparison purposes. The sampling was performed to address possible fungal concerns related to a moisture intrusion event which occurred during the fall of 2016 as a result from a significant precipitation event. FUNGAL PARTICULATE AIR SAMPLING Samples were collected at approximately 2:00p.m. during normal HVAC operations. Samples were collected using Allergenco-D sampling cassettes (spore traps) with a high-volume vacuum pump. Each sample was collected at a flow rate of 15 Liters per minute for ten (10) minutes (150 liters total per sample) from approximately four (4) feet above floor level. Samples were submitted under chain of custody to Lab/Cor, Inc. of Seattle, Washington for non-viable fungal particulate identification and quantification by optical microscopic methods. Below is a table summarizing the laboratory results. Table 1: Fungal Particulate Air Sample Results Sample Number Sample Location Total Count ST-01 Outdoor; comparison 1,275 ST-02 Hallway adjacent to Room 514T 115 ST-03 Room 509 10 ST-04 Room 617 10 ST-05 2 nd floor; commons area adjacent to Room 617 60 400 Bradley Boulevard, Suite 300, Richland, WA 99352 509.942.1600 Main 866.727.0140 Fax www.pbsenv.com Bend Boise Coos Bay Eugene Portland Seattle Tri-Cities Vancouver Walla Walla

Chuck Doan Proposal for Fungal Sample Results, Eisenhower High School November 19, 2016 Page 2 of 2 Overall, total fungal particulate concentrations were lower indoors compared to outdoor fungal particulate concentrations. While the predominant types of fungal particulates identified in the samples collected from indoors are also identified in the outdoor sample, some fungal particulates identified in the indoor samples are not identified in the outdoor sample. With the exception of Myxomycetes/Periconia/Smuts and rust spores, all the types of fungal particulate matter identified and their relative concentrations in the samples, both indoors and outdoors, are typical of the fungal particulate matter observed in samples collected from school sites throughout the region. CONCLUSIONS Airborne fungal particulate concentrations identified in samples collected from indoors are significantly lower than outdoor concentrations. No unusual or musty odors were observed during this sampling event. There does not appear to be a significant airborne fungal particulate concern in the areas sampled at Eisenhower High School at the time of this sampling event. LIMITATIONS The findings and conclusions in this report are limited to the areas inspected as well as the professional judgment concerning the significance of the data gathered during the investigation. Only accessible areas and materials were examined during this investigation Please feel free to contact me at 509.942.1600 or john.price@pbsenv.com with any questions or comments. Sincerely, PBS Engineering and Environmental Inc. John Price Sr. Project Manager - IH Attachments: JPr L:\Projects\64000\64300-64399\64361_YakimaSD\64361.001_Eisenhower\Phase 0001\Reports\FnglRpt_IkeBlueWall_111916.docx 64361.001

Job Number: 161004 SEA Address: 1220 SW Morrison St Suite 600 Portland, OR 97205 PO Number: Sub Project: Analysis Report Cover Enclosed please find results for samples submitted to our laboratory. A list of samples and analyses follows: Report Date: 11/19/2016 Lab/Cor Sample # Client Sample # and Description Analysis Analysis Notes Date Received: 161004 - S1 ST-01 - Exterior; Courtyard Under NV, Air, Fungal ID 11/19/2016 Sky Bridge 161004 - S2 ST-02 - Interior; Main Hall Across NV, Air, Fungal ID 11/19/2016 From Skit 161004 - S3 ST-03 - Interior; Room 509 South NV, Air, Fungal ID 11/19/2016 Wall 161004 - S4 ST-04 - Interior; Room 617 South Wall NV, Air, Fungal ID 11/19/2016 161004 - S5 ST-05 - Interior; 2nd Floor Commons NV, Air, Fungal ID 11/19/2016 Nonviable Air Air samples follow preparation and analysis techniques outlined in Method 5 of the laboratory SOP; this method is based on guidelines from the Pan-American Aerobiology Association Standardized Protocol and ASTM Method 7391-09. Samples were collected using either an Air-O-Cell, Cyclex D, Allergenco-D, or M2 Multi-Mold nonviable air sampling cassette. Characteristic morphologies were observed by optical microscopy at a magnification of 600x. For each individual particle type observed, data was reported in particles per cubic meter of air (m3). Due to various factors that influence uncertainty (media type, particle loading, staining, instrumentation and other variable aspects of the method), only the first two figures reported are considered to be significant. The area analyzed on each sample is 20%. Disclaimer The results reported relate only to the samples tested or analyzed; the laboratory is not responsible for data collected by personnel who are not affiliated with the laboratory. Results reported in both structures/cm3 and structures/mm2 are dependent on the sample volume and area. These parameters are measured and recorded by non-laboratory personnel and are not covered by the laboratory s accreditation. Interpretation of these results is the sole responsibility of the client. If further clarification of these results is needed, please call us. Thank you for allowing the staff at Lab/Cor, Inc. the opportunity to provide you with the analytical services. Sincerely, Ashley Tonge Technician/Analyst Page 1 of 4

Job Number: 161004 Date Received: 11/19/2016 Nonviable Air Lab/Cor ID: Sample No.: Description: S1 ST-01 Exterior; Courtyard Under Sky Bridge S2 ST-02 Interior; Main Hall Across From Skit Sample Measure: Media Type: Fungal-AllergencoD Fungal-AllergencoD Analyst - Analysis Date: AT - 11/19/2016 AT - 11/19/2016 MRL: Scope - Magnification: Olympus BHT-BH2-600 Olympus BHT-BH2-600 Notes: Fungal Identification Raw Count* Total Count** Total/m³ Raw Count* Total Count** Total/m³ Ascospores 24 120 800 4 20 1 Aspergillus/ Penicillium-like 15 75 500 1 5 Aureobasidium 1 5 Basidiospores 173 865 5767 15 75 500 Cladosporium 38 190 1267 2 10 67 Epicoccum 1 5 Hyphal Fragments 1 5 Myxo./ Periconia/ Smuts 1 5 Oidium/ Peronospora 1 5 Rust Spore Ulocladium 1 5 Summary Total: 255 1275 8499 23 115 766 * - Raw Counts per 20% of Sample ** - Total Count per Sample Page 2 of 4

Job Number: 161004 Date Received: 11/19/2016 Nonviable Air Lab/Cor ID: Sample No.: Description: S3 ST-03 Interior; Room 509 South Wall S4 ST-04 Interior; Room 617 South Wall Sample Measure: Media Type: Fungal-AllergencoD Fungal-AllergencoD Analyst - Analysis Date: AT - 11/19/2016 AT - 11/19/2016 MRL: Scope - Magnification: Olympus BHT-BH2-600 Olympus BHT-BH2-600 Notes: Fungal Identification Raw Count* Total Count** Total/m³ Raw Count* Total Count** Total/m³ Ascospores Aspergillus/ Penicillium-like Aureobasidium Basidiospores Cladosporium 1 5 1 5 Epicoccum Hyphal Fragments Myxo./ Periconia/ Smuts 1 5 Oidium/ Peronospora Rust Spore 1 5 Ulocladium Summary Total: 2 10 66 2 10 66 * - Raw Counts per 20% of Sample ** - Total Count per Sample Page 3 of 4

Job Number: 161004 Date Received: 11/19/2016 Nonviable Air Lab/Cor ID: Sample No.: Description: S5 ST-05 Interior; 2nd Floor Commons Sample Measure: Media Type: Fungal-AllergencoD Analyst - Analysis Date: AT - 11/19/2016 MRL: Scope - Magnification: Olympus BHT-BH2-600 Notes: Fungal Identification Raw Count* Total Count** Total/m³ Raw Count* Total Count** Total/m³ Ascospores Aspergillus/ Penicillium-like Aureobasidium 1 5 Basidiospores 7 35 2 Cladosporium 2 10 67 Epicoccum Hyphal Fragments 1 5 Myxo./ Periconia/ Smuts Oidium/ Peronospora 1 5 Rust Spore Ulocladium Summary Total: 12 60 399 Reviewed by: Ashley Tonge Technician/Analyst * - Raw Counts per 20% of Sample ** - Total Count per Sample Page 4 of 4