BERA The HOMOTH ABR / BERA- module is a real time brainstem audiometer. It is developed considering the latest knowledge of the ENT research.

Similar documents
TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

Neuro-Audio Version 2010

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

ERO SCAN. Otoacoustic Emission Testing

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Oscilla - excellence since 1960

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

Reliable, flexible & precise

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

Handheld OAE-Tympanometry Combination System

OtoAcoustic Emissions (OAE s)

The following describes general use of ELIOS device

Bio-logic AuDX PRO FLEX Diagnostic OAE and audiometry Quick start guide

ABR Screener Excellence in Newborn Hearing Screening

by Maico Diagnostics

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

The Effect of Analysis Methods and Input Signal Characteristics on Hearing Aid Measurements

General Catalogue. Product Line for Hearing Screening & Diagnostics

III. Comprehensive. Efficient. Auditory EP Testing

Quick Guide - eabr with Eclipse

the truly automated all-in-one hearing screener

ABR Screener Excellence in Newborn Hearing Screening

Audiology. Anita Gáborján MD, PhD.

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Application of a Stimulus Spectral Calibration Routine to Click Evoked Otoacoustic Emissions

Advanced otoacoustic emission detection techniques and clinical diagnostics applications

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

Educational Module Tympanometry. Germany D Germering

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

General Catalogue. Hearing Screening & Diagnostics

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

General Catalogue. Product Line for Hearing Screening & Diagnostics

Protocol for Fast, Efficient Audiogram Prediction using Electrophysiology. Sponsored By

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

The registration testing for audiometric device in CFDA

General Catalogue. Product Line for Hearing Screening & Diagnostics

QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

Bio-logic AuDX PRO FLEX Quick start Quick start guide

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

ISIS IOM. System-Family. The new ISIS Xpress supplements the ISIS IOM System-Family >> APPLICATION FIELDS: >> Powerful >> User-friendly >> Flexible

AURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04

ADHEAR The new bone-conduction hearing aid innovation

General Catalogue. Hearing Screening & Diagnostics

The first choice for design and function.

Testing Digital Hearing Aids

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

Phonak Target 4.3. Desktop Fitting Guide. Content. March 2016

AC40. The true clinical. hybrid

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

James W. Hall III, Ph.D.

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

Hearing Screening, Diagnostics and Intervention

AUDL GS08 and GAV1: 2013 Final exam page 1/13. You must complete all sections. Label all graphs. Show your work!

Hearing Evaluation: Diagnostic Approach

Audiology Equipment p r o d u c t s c AtA l o g u E

Glossary For Parents. Atresia: closure of the ear canal or absence of an ear opening.

Tune in on life with SCOLAbuddy. A new fm receiver from Widex

2/16/2012. Fitting Current Amplification Technology on Infants and Children. Preselection Issues & Procedures

(Otoacoustic Emissions and Automated ABR)

Acoustics, signals & systems for audiology. Psychoacoustics of hearing impairment

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

EEL 6586, Project - Hearing Aids algorithms

HEARING IMPAIRMENT LEARNING OBJECTIVES: Divisions of the Ear. Inner Ear. The inner ear consists of: Cochlea Vestibular

Abstract. 1 Introduction

Issues faced by people with a Sensorineural Hearing Loss

THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS

Electrotherapy, ultrasound therapy, combined therapy, laser therapy and magnetotherapy Etius ULM

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

Bone conduction hearing solutions from Sophono

Desktop Fitting Guide for Phonak Brio 3

PFL780 PCB Fault Locator

Audiology Services. Table of Contents. Audiology Services Guidelines : Hearing services

QUICK START GUIDE SENTIERO DESKTOP DIAGNOSTIC (WHITE HOUSING)

Signals, systems, acoustics and the ear. Week 5. The peripheral auditory system: The ear as a signal processor

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

UNDERSTANDING HEARING LOSS

UNDERSTANDING HEARING LOSS

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

Transcription:

BERA 4000 The HOMOTH ABR / BERA- module is a real time brainstem audiometer. It is developed considering the latest knowledge of the ENT research. By use of most modern processors, a wide range of possibilities is opened. It is a system lasting into the future for a lot of years, because all changes in diagnostic demands can be loaded as an update or upgrade via software into the system. The software contains pre-selected standard programs, to reduce the operation of the system onto a few keymoves. Beside this, it is possible to create storable measuring programs with individual parameter selections. Further more, the EXPERT-MODE allows to create and change settings during measurement sessions and adapt to changing situations or patients condition. 16 curves can be measured per examination and stored into a temporary memory. The evaluation / analysis can be done afterwards at a later time. All curves are presented high resolution at the colour screen of PC. The program is menu controlled and fitted with a online help. The brainstem system is expandable with electronystagmografy (ENG/VNG) and/or otoacoustic emissions (OAE). Technical data system: micro processor controlled with measurement of electrodes impedance system requirements: Pentium PC min. 500 MHz, USB 2.0 port, Window 98, ME, 2000, XP standards: EN 60601-1 / 1-1 / 1-2 and AGERA rules isolation: galvanic separated electrodes stimulus: 1. click 50-500 us 2. sinus ( in preparation ) polarity: positive, negative and alternating intensity: 0-110 db SPL rate: 1-50 per sec in 0,1 steps masking: 0-80 db white noise measurement: 1 channel ( ipsi / contra ) EEG amplifier 80 db / input imp. > 48 MOhm / automatic or manual gain selection converter: A/D 12 bit / 100 khz averager: max 10.000 sweeps analysis time: 10 ms (early potentials) artefacts: online elimination ( time and amplitude ) filters: 1. highpass 100-150 - 200-300 Hz 2. lowpass 1-2 - 3-8 khz 3. software filters 4. 50 Hz notch filter results: 1. curve diagrams 8x right und 8x left 2. latency diagram 3. direct comparison right / left dimensions W= 32 / D= 27 / H= 7,5 cm weight 1,8 Kg measure cable, lenght 275 cm + 60 cm electrodes cable power consumption 13,2 V 15 W Rev.04 / Stand 01-2007 accessories: 1 headphone DT 48 A 1 measure cable with 3 electrode clamps, red - yellow - black 1 bag standard electrodes at 50 pieces 1 power pack 1 set cables 1 program CD 1 instruction manual for technical modifications all rights reserved HOMOTH Medizinelektronik GmbH & Co KG, Baumacker 1a, 22523 Hamburg Tel.:..49..40-54 72 65 0 Fax:..49..40-54 72 65 50 Internet //www.homoth.de e-mail: info@homoth.de

System : PC-module with microprozessor controller and USB 2.0 port system requirements: Pentium PC min. 500 MHz, USB 2.0 port, Window 98, ME, 2000, XP Standard : EN 60601-1 / 1-1 / 1-2 / MPG / NUB rules Stimulus : 562 Hz to 9,843 khz Intensity : 0,5 db SPL to 70 db SPL choosable in 0.5 db steps level differences free selectable Probe : miniature design with pressure ventilation and half autom. self-cleaning Probe control : with best-fit-test and realtime control view of stimulus and spectrum Averaging : all sweeps can be averaged in time- or spectralarea Results-presentation : DP-graph with signal, noise, and the corresponding spectrum input / output function - slope - hearing loss in HPL alternatively evaluation of DP 1 = 2F 1 - F 2 or DP 2 = 2F 2 - F 1 Dimensions / weight : 290 X 250 X 75 mm ( B, L, H) / 1,8 Kg (probe-weight 12 g) Probe cable: 2000 mm, flexible with fastening clip Power pack : + 13,2 V = (MSELV) / 15 W Accessories : 1 miniature probe complete 30 earplugs in 5 different sizes 1 external power pack 1 USB cable 1 program CD 1 instruction manual Rev.04 / Stand 01-2007 DP-OAE 4000 Lately the Otoacoustic Emissions (OAE) have become more and more important in the field of objective diagnosis at sensorineural deafness. Using the T-OAE measurement (Transient Evoked Otoacoustic Emissions) clicks will cause a wide-band-irritation, using the DP-OAE s specific frequencies for irritation, (Distorsion-Products Otoacoustic Emissions) it is possible to provoke, measure and evaluate frequency related parts of the cochlear. A sound proof cabin is not necessary, only a noise-reduced area. By continuous stimulation with two presetable primary sinus tones(f1, f2), the selected area of the cochlea is provoked. The DP-OAE method increasingly rises in clinical means. This unproblematic and quick measurement is suitable for all age groups. Especially as a precaution-examination for children and newborns this method is established worldwide. In this occasion, already a low distinctive hearing-loss, at the begin of a deafness, can be recognized. From screening measurements in the paediatrics using 4 frequency-areas up to clinical examinations containing 10 frequency-areas, the HOMOTH DP-OAE 4000 covers the entire spectrum of test demands of regular DP OAE measurements. The two measure-requirements DP 1 = 2F 1 - F 2 or DP 2 = 2F 2 - F 1 and averaging in time or in spectral area, makes this device suitable to a wide range of diagnostic. In addition, the HOMOTH DP-OAE offers a Hearingloss-Mode. Using this mode, a predefined (By doctor or audiologist) number of frequencies is tested by decreasing the input of SPL. The SPL range lasts from 70dB to 0,5dB splitted into 0,5dB steps. Using an algorithm, the DP-OAE software is able to determin the hearingloss. This method is very helpful in cases a real tone-audio can not be realized. Ensuringing the optimal positioning of the probe, a best-fit-test is integrated. A volume measurement is testing probe-stability during the complete measurement. In order to make measurements more reliable, two additional methods of surpressing artefacts and unwanted responses are used. First, a third frequency (f3, surpressor tone) can be added in order to avoid finestrukture of the response and work out the distorsion products with very high quality. Second, the output is set into a phase-relation to the inputsignal. Doing this, steady occuring artefacts will be spotted, specially marked and taken out of the evaluation. The results of the diagnostics are diplayed within the following graphics: DP-Diagram, Input/Output-Funktion, Slope, Hearing-Loss-Diagram. A special 3-D graphic allows to see all evaluated curves in one diagram, which can be turned into all directions for easy analysis. All data is stored on harddisc of the computer. Other HOMOTH diagnostic-moduls can be connected to the computer and use the same patients-datafiles. technical modifications reserved technical data HOMOTH Medizinelektronik GmbH & Co KG, Baumacker 1a, 22523 Hamburg Germany Tel.:..49-40-54 72 65 0 Fax:..49-40-54 72 65 50 Internet //www.homoth.de e-mail: info@homoth.de

T-OAE 4000 As a world novelty, HOMOTH treads new paths in evaluating results of measured Otoacoustic Emissions. All measured data is classified according to signalstatistic and signaldynamic features. The result is transmitted to an expert system as parameter vectors. The expert system, containing compares all parameter vectors with the stored samples. more than 10.000 evaluated OAE measurements, The analysis module consists of an artificial neuronal network, supplemented by modern fuzzy logic. The result is transmitted to the personal computer, via USB port, and is presented on the monitor. Using the HOMOTH expert system an objective result of a hearing test, comparable to subjective evaluation of an experienced OAE expert, is possible. The actual measured data is compared and evaluated automatically within a few seconds. So everybody is able to use the special knowledge of many OAE experts. The analysis module evaluates the signalstatisticand the signaldynamic parameters, the artefacts are eleminated and the characteristic components of the emissions are isolated. The screen shows the SOAE, TE-OAE and the artefacts. Therefore the HOMOTH expert system also allows the untrained user of the OAE system, a very high safety regarding the statement of result. As for a classical OAE measurement, all relevant diagrams are displayed at the monitor. The HOMOTH TE-OAE expert connects all advantages of the classical OAE diagnostic with the most modern computer technology as neuronal networks and fuzzy logic. Technical data system requirements : standards : stimulus : intensity : probe : converter : amplifier : measurement : artefacts : results presentation : dimensions/ weight : probe-cable: power consumption : accessories : Rev.04 / Stand 01-2007 Pentium PC min. 800 MHz, Windows 98 / ME / 2000 / XP USB port version 2.0 or free PCI 2.1-slot with USB Port 2.0 EN 60601-1 / 1-1 / 1-2 / MPG / NUB rules clickquartett ( 3 pos. / 1 neg. ) 20 ms rate ca. 80dB with automatical gain control miniature design with pressure ventilation realtime probe control via FFT 12Bit / 100kHz 80dB with automatical gain setting manual adjustable 16,32,64,128,256,512 clickquartetts automatical artefact recognition and elemination, time window with two correlating measurements in different colours time window with the spontaneous emissions maxima of the emissions realtime spectrum of the stimulus spectrum of the emissions / spectrum of the noise ZF correlation F/t parameter for SNR, stability, reproduction numbers of the artefacts and the given stimuli automatical analysis of the results after the expert system ( certain positiv, positiv, poor positiv, negativ, certain negativ ) 290 X 250 X 75 mm ( W, D, H) / 1,8 Kg 2000 mm, high flexible with a patients clip for fastening 15 W 1 miniature probe, complete with 30 ear plugs in 5 different sizes 1 extern power pack 1 communikation cable USB 2.0 1 program CD 1 instruction manual for technical modifications all rights reserved HOMOTH Medizinelektronik GmbH & Co KG, Baumacker 1a, 22523 Hamburg Tel.: +49..40-54 72 65 0 Fax: +49..40-54 72 65 50 Internet //www.homoth.de e-mail: info@homoth.de