SKY Titanium Implants Easy & safe prosthetically versatile
3D osseo connect surface (ocs ) Depending on the implant s positioning, a corresponding coronal implant design is needed for optimally fulfilling the requirements of the various hard and soft tissues. Isocrestal implant position In this implant position, the soft-tissue attachment takes place predominantly on the abutment. A soft-tissue cuff is made on the implant for long-term bone protection. 1 st dimension The narrow finished surface with micro grooves optimally protects the accumulation of epithelial tissue. 1,2 1,1 1,9,8,7,6,,4,3,2,1 Finished surface Gingival attachment 2 nd dimension The narrowly etched surface with the uniform velvety structure stabilizes connective tissue. 17, 1 12, 1 7, 2, Etched surface Connective tissue stabilization 3 rd dimension The blasted and hightemperature etched surface offers the ideal coarseness for osseous integration. The macro grooves support longterm bone preservation. Indication 22, 2 17, 1 12, 1 7, 2, Blasted, etched surface Osseous anchoring The crestally structured bluesky implant is ideal - for placing the implant flush with the bone - for preserving the bone - for use in the augmented ridge - for improving the primary stability - Implant position flush with the bone - Augmented implant site 2 Tel. (+49) 73 9 / 8 72-4 4 Fax (+49) 73 9 / 8 72-4 44 www.bredent-medical.com
Supracrestal implant position In this implant position, the soft-tissue attachment takes place predominantly on the implant. For this reason, the coronal implant design must be adapted to these requirements. Finished surface Gingival attachment 1,2 1,1 1,9,8,7,6,,4,3,2,1 1 st dimension The highly finished surface with micro grooves offers a wide space for the epithelial attachment and is easy to clean in the recall. Etched surface Connective tissue stabilization 17, 1 12, 1 7, 2, 2 nd dimension The widely etched surface with the velvety structure stabilizes connective tissue. Blasted, etched surface Osseous anchoring Indication 22, 2 17, 1 12, 1 7, 2, 3 rd dimension The blasted and hightemperature surface offers the ideal coarseness for osseous integration. The SKY implant is ideal to avoid milling off bone in narrow or uneven ridges. The machined section avoids accumulation of plaque to exposed implant necks. In transgingival implant insertion, depth control is made easier. Short implants in an interlocked construction, anchored 6. mm into the bone. 3
One only for four = high economy Four diameters One platform Exposure Impression closed tray open tray Ø 3, Esthetic impression (available autumn 211) Ø 4, implant analog Ø 4, gingiva former Esthetic gingiva former Ø, SKY temp 4 Tel. (+49) 73 9 / 8 72-4 4 Fax (+49) 73 9 / 8 72-4 44 www.bredent-medical.com e-mail info-medical@bredent.com
Perfect prosthetic solutions with just a few components Titanium abutments R R Titanium abutments esthetic line R Individual abutments Zirconium abutments (available autumn 211) R SKY fast & fixed Ball attachments Bar abutments Locator
Most advanced implant design with osseo connect (ocs ) surface for high primary stability and long-term implant success bluesky and SKY are based on the same tried and tested design and set with the same instruments. Compression thread Improving the bone quality Thanks to the bone quality-oriented surgical procedure and the compression thread the bone around the implant is condensed and hence primary stability is increased. Implantats and abutments made from titanium grade 4KV Homogeneous system The exceptional properties of titanium grade 4 KV form the basis for the implants, abutments and screws. Titanium Mechanical properties Designation Grade 2 Grade 3 Grade 4 Grade 4 KV Condition cold-formed Tensile strength N/mm 2,2% yield limit N/mm 2 min. 34 23 2 4 3 18 44 1 8-9 > 7 > 1 Elongation at fracture % min. 6 Tel. (+49) 73 9 / 8 72-4 4 Fax (+49) 73 9 / 8 72-4 44 www.bredent-medical.com e-mail info-medical@bredent.com
Unique implant/abutment connection = exceptional stability Firmly connected Hexagon Edge contact High rotation Loosening of screws is practically excluded thanks to the very long tubein-tube connection. Reduced rotation Surface contact achieved by the modified Torx results in increased precision of fit while maitaining the same manufacturing tolerance. Torx Surface contact Low rotation 12 positions Parallel alignment of the abutments can always be achieved thanks to a Torx turned by 3. 6 Fast, safe and atraumatic placement of implants turned by 3 Removing and screwing in implant and cover screw without changing the instrument. 2 1 The implant is safely held with the conical Torx. Open the new double sterile packaging. Remove the implant with the insertion instrument for the ratchet or the contraangle. Das Implantat wird inseriert und kann direkt eingeschraubt werden. 4 3 The cover screw is safely held in place with the cone. Use the same instrument to remove the cover screw... The cover screw is screwed directly on the implant. The flat cone ensures that the screw is pulled only slightly and cannot tilt. 7
s and diameters Ø 3, bsky31 Ø 3, ksky31 bsky312 ksky312 bsky314 ksky314 16 mm bsky316 16 mm ksky316 Ø 4, bsky48 Ø 4, ksky48 bsky41 ksky41 bsky412 ksky412 bsky414 ksky414 16 mm bsky416 16 mm ksky416 Ø 4, bsky48 Ø 4, ksky48 bsky41 ksky41 bsky412 ksky412 bsky414 ksky414 Ø, bsky8 bsky1 bsky12 OP-Tray Five implants one instrument set TK ratchet screw-in insert long short SKY-STK6 SKY-STK TK screwdriver insert SKYXOT21 mini 1 mini 2 long short SKY-WTK6 SKY-WTK Learn more about the SKY family in the following brochures: - whitesky zirconium implant - SKY Presentation of the system bredent medical GmbH & Co.KG Weissenhorner Str. 2 892 Senden Germany Tel. (+49) 73 9 / 8 72-4 4 Fax (+49) 73 9 / 8 72-4 44 www.bredent-medical.com e-mail info-medical@bredent.com Subject to changes 3/11 447 GB 3