Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

Similar documents
Tangent field technique of TomoDirect improves dose distribution for whole-breast irradiation

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Corporate Medical Policy

3D-CRT Breast Cancer Planning

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

Defining Target Volumes and Organs at Risk: a common language

Additional Questions for Review 2D & 3D

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Fuli Zhang, Weidong Xu, Huayong Jiang, Yadi Wang ( ), Junmao Gao, Qingzhi Liu

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Protocol of Radiotherapy for Breast Cancer

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Chapters from Clinical Oncology

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Radiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

The choice of multi beam IMRT for whole breast radiotherapy in early stage right breast cancer

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

IMRT Planning Basics AAMD Student Webinar

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana

Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast Cancer: A Dosimetric Study

Computerized Treatment Planning in Radiation Therapy of Intact Breast: Influence of Number of CT-Cuts

Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

Implementation of Hybrid IMRT Breast Planning

Elective breast radiotherapy including level I and II lymph nodes: A planning study with the humeral head as planning risk volume

Dosimetric Comparison of Intensity-Modulated Radiotherapy versus 3D Conformal Radiotherapy in Patients with Head and Neck Cancer

Citation for published version (APA): Laan, H. P. V. D. (2010). Optimising CT guided radiotherapy for breast cancer Groningen: s.n.

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Commission, Ganakbari, Savar, Dhaka, Bangladesh

Variation In Mean Heart Dose By Treatment Plan Optimization During Radiotherapy For Left Sided Breast Cancer

Tomohisa FURUYA*, Satoru SUGIMOTO, Chie KUROKAWA, Shuichi OZAWA, Kumiko KARASAWA and Keisuke SASAI

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

Chapter 2. Level II lymph nodes and radiation-induced xerostomia

Clinical experience with TomoDirect System Tangential Mode

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Arab Journal of Nuclear Sciences and Applications

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

The Physics of Oesophageal Cancer Radiotherapy

VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Evaluation of the Dynamic Arc-Therapy in Comparison to Conformal Radiation Therapy in Radiotherapy Patients

BLADDER RADIOTHERAPY PLANNING DOCUMENT

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Influence of different boost techniques on radiation dose to the left anterior descending coronary artery

biij Initial experience in treating lung cancer with helical tomotherapy

Planning Optimization of Conformal Radiotherapy Techniques for Meningioma Brain Tumors

Knowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101. Cases from Duke Clinic. Deon Martina Dick

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Correspondence should be addressed to Richard L. Bakst;

Dose prescription, reporting and recording in intensity-modulated radiation therapy: a digest of the ICRU Report 83

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

Evaluation of three APBI techniques under NSABP B-39 guidelines

Alexandria University Faculty of Medicine. Alexandria Journal of Medicine.

Comparing Study between Conventional and Conformal Planning Radiotherapy

Institute of Oncology & Radiobiology. Havana, Cuba. INOR

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

Mahdi Aghili*, Parisa Seifi, Farshid Farhan, Ahmad Reza Sebzari, Ehsan Mohamadi, Vahid Vaezzadeh a

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

9.5. CONVENTIONAL RADIOTHERAPY TECHNIQUE FOR TREATING THYROID CANCER

IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS. A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University

Corporate Medical Policy

Dosimetric Comparison of Three Different External Beam Whole Breast Irradiation Techniques

PRONE BREAST WHAT S THE BIG DEAL? Rachel A. Hackett CMD, RTT

Protection of the contralateral breast during radiation therapy for breast cancer

GUIDELINES FOR RADIOTHERAPY IN EARLY BREAST CANCER

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Guang-Hua Jin 1,2, Li-Xin Chen 1*, Xiao-Wu Deng 1, Xiao-Wei Liu 2, Ying Huang 1 and Xiao-Bo Huang 1

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Aytul OZGEN 1, *, Mutlu HAYRAN 2 and Fatih KAHRAMAN 3 INTRODUCTION

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

New Technologies for the Radiotherapy of Prostate Cancer

Specification of Tumor Dose. Prescription dose. Purpose

Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

Comparative Study of 3DCRT versus IMRT in Post lumpectomy Early Stage Breast Cancer Patients

IMAT: intensity-modulated arc therapy

BCCR ORIGINAL ARTICLE

Transcription:

ORIGINAL ARTICLE Dosimetric Comparison of Different 3DCRT Techniques in Left Breast Cancer Radiotherapy Planning Abdus Sattar Mollah 1 and Meher Niger Sharmin 2 1 Department of Medical Physics, KhwajaYunus Ali University, Enayetpur, Sirajgonj 2 Khwaja Yunus Ali Medical College Hospital Cancer Center, Enayetpur, Sirajgonj Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj - 6751, E-mail: mollahas@gmail.com ABSTRACT Treatment plan of 10 patients with left-sided breast cancer treated to a prescribed dose of 50 Gy in 25 fractions were selected. The treatment plans were generated by using an Elekta Precise PLAN treatment plan system (TPS) in three different ways namely M1 method, M2 method and M3 method for evaluation of dosimetric parameters based on three dimensional conformal radiotherapy (3DCRT) technique. Pencil beam calculation algorithm was used for dose calculation of Planning Treatment Volume (PTV) as well as Organ At Risk (OAR), with heterogeneity corrections. Plans were compared according to dose-volume histogram (DVH) analysis in terms of PTV homogeneity and conformity indices (HI and CI) as well as OARs dose and volume parameters. All the three treatment methods achieved comparable radiation dose delivery to PTV-95% of the prescribed dose covering > 95% of the breast PTV. The mean volume of PTV receiving 105% (V 105 ) of the prescribed dose was 2.12% (range 0-5.7%) for M1 plan, 1.9% for M2 plan, and 3.08% for M3 plan. The homogeneity and conformity indices (HI and CI) were similar for M1 plan and M2 plan, whereas the M3 plan had better conformity index at the cost of less homogeneity. The low-dose volumes (V 5Gy ) in the heart and lungs were larger in M1 plan than in the other methods. The value of the mean dose to the ipsilateral lung was higher for M2 plan than the values for with M1 plan and M3 plan. Compared with M1 and M3 plan, M2 plan proved to be a simple planning method for 3DCRT breast irradiation. Keywords: Breast cancer, 3DCRT, dosimetric parameters, treatment planning system (TPS) INTRODUCTION Breast cancer constitutes approximately 26% of all cancers in women. Breast cancer incidence increases at a rate of 1-2% throughout the world and each year approximately one million new cases are diagnosed (1). External Beam Radiation Therapy (EBRT) is the most common type of radiation used to treat breast cancer. Three-dimensional conformal radiotherapy (3DCRT) uses multiple radiation fields to deliver precise while sparing normal tissue. 3DCRT/quadrant breast irradiation delivers radiation to only a small portion of the breast. Multiple, targeted beams reduce the chances for irradiation of the critical organs such as heart and lungs. Three-dimensional (3D) conformal radiation therapy is a technique where the beams of radiation used in treatment are shaped to match the tumor. The radiotherapy techniques in the treatment of breast cancer vary in different institutions (2-5), but, in general, the issue of radiation dose delivery to the chest wall after total mastectomy or to the breast following breast conservation surgery remains complex. Many earlier works had addressed the efficacy (single or double isocenter) of three-dimensional computerized tomography (3D-CT)-based treatment planning and field shaping, as well as better dose conformity by applying multi-leaf collimator (MLC) optimized tangential beams using field-in-field techniques, in achieving better radiotherapy plans (6-9). Among these combinations with methods like single isocenter, multiple isocenter, half-beam, or full beam are generated. A significant problem with treatment using different isocenters is undesirably increased radiation doses due to overlapping of fields. At this point, the use of a single isocenter seems to be a suitable solution. However, in the literature we did not find a study comparing one and twoisocenters 3DCRT planning. 108

Bangladesh J. Nucl. Med. Vol. 17 No. 2 July 2014 Mollah et. al. A tremendous evolution in treatment process has occurred in recent years. This allowed the delivery of the desired radiation dose distribution to target tissue, while delivering an acceptable radiation dose to the surrounding normal tissues with greater dose gradients and tighter margins. Although breast treatment methods continuously improve with developments in technology, there is still not an accepted standard method. The most commonly used easy access method is 3DCRT planning (7). The treatment planning system (TPS) has a central role in the application of 3DCRT. A modern TPS has more sophisticated calculation algorithms, providing more accurate dose calculation capabilities with 3DCRT delivery techniques. At KYAMCH Cancer Center, different beam configuration/isocenter techniques (10) are being used for breast cancer treatment based on 3DCRT plan with pencil beam/convolution algorithm. The main purpose of this study was to evaluate the dose delivery parameters of the isocentric variable angle with parallel opposed tangential fields in the treatment of left breast cancer by using Elekta Precise PLAN treatment planning system with pencil beam algorithm for different 3DCRT planning methods. This study also aimed to minimize the radiation dose to organs at risk (OAR) other than the planning target volume (PTV) during radiation therapy applied for left breast cancer, by using different planning methods based on 3DCRT. MATERIALS AND METHODS The radiotherapy treatment data of 10 patients with left-sided breast cancer previously treated (10) with 3DCRT at the KYMCH Cancer Center, Enayetpur, Sirajgonj were selected. Computed tomography (CT) scans from 10 patients previously treated were selected for this dosimetric study. All patients received a prescribed dose of 50 Gy to the left breast in 25 fractions. Patients underwent standard CT simulation at 3.5 mm slice spacing, in the supine position on an angled breast board. Before simulation, the patient was placed supine on a commercially available breast tilt board to make sternum parallel to the table, with both arms fully abducted (90 degrees or greater) and externally rotated and head position was secured. The PTV was created by adding a uniform margin of 10 mm around the clinical treatment volume (CTV). The PTV (the chest wall or the left breast) and OAR, such as the heart, ipsilateral lung and contralateral lung, were delineated in 3.5mm thick CT slices. For left breast cancer treatment, these OARs are expected to expose more radiation dose. The field borders were clinically defined with radiopaque wires during simulation and also delineated according to the location of the tumor, extent of breast tissue, and adequate set-up margins. The CT images were transferred to Elekta Precise PLAN TPS for radiotherapy treatment planning. All plans were generated using 6 MV photons from an Elekta Precise linear accelerator equipped with an 80 multileaf collimator (MLC). The 3DCRT plans of the three different treatment methods were compared for evaluation of dosimetric parameters. Treatment planning was done by using three different methods to supraclavicular area, internal and external tangential fields. Details of the beam arrangements and objectives of plans are described below: M1: Different isocenter, supraclavicular area half, breast half beam-planning was set as supraclavicular area half beam, and tangential field half beam with different isocenter. M2: Single isocenter, supraclavicular area half, breast half beam-planning was set as supraclavicular area half beam, and tangential field half beam with single isocenter. M3: Different isocenter, supraclavicular area full beam, breast full beam-planning was set as supraclavicular area full beam, and tangential field full beam with different isocenter. 109

Dosimetric Comparison of Different 3DRCT Bangladesh J. Nucl. Med. Vol. 17 No. 2 July 2014 On each of the three planning methods, three objectives were fulfilled before the plan was accepted: i) target coverage heterogeneity within +7% and 5% of the prescribed dose (according to ICRU), ii) OAR sparing to at least the limits stated in Table 1, and iii) sparing of healthy tissue. The number of fields and the beam geometry were fixed in order to avoid variability in the results due to different beam arrangements. In planning method, the beam arrangement consisted of two parallel opposing tangential beams ensuring the best possible coverage of the breast tissue and minimizing the dose to the adjacent critical structures (i.e., ipsilateral lung and heart). The "isocenter" of the treatment machine is positioned at the centre point of the midline joining two parallel opposing fields. Dynamic wedges were then added to both tangential beams in order to improve the dose uniformity to the PTV. Efforts were made to minimize volumes of heart and lung that unavoidably get included within the field borders. Typical tangential beam arrangement with OAR for left breast is shown in Figure 1. The lateral beam eye view (BEV) of the PTV with MLCdefined port displayed is shown in Figure 2. Figure 2. Lateral BEV of the PTV with MLC-defined port displayed The dose prescribed according to the International Commission on Radiation Units and Measurement (ICRU) Reports 62 and 50 recommendations (11,12). The dose was prescribed to the ICRU reference point, which was usually the iso-center located in the PTV volume centroid. At least 98% of the planned target should receive at least 95% of the prescribed dose, and 2% of the planned target should receive at the outside 107% of the prescribed dose, while a homogeneous dose within 95%-107% of the prescribed dose at target intended to obtain. A dosimetric comparison of the heart was conducted using V 30, V 5, and the mean dose. The ipsilateral lung was also evaluated using V 20 and V 5 (Table 1). Table 1: Dose-volume constraints for targets and critical structures Figure 1. Typical beam arrangement for the two tangential fields with wedges and OAR for left breast irradiation. Two tangential semi-opposed beams and a multi-leaf collimator were used for different 34DCRT planes. Tangential fields that covered the contoured target volume with MLC blocks and wedges were designed. 110

Bangladesh J. Nucl. Med. Vol. 17 No. 2 July 2014 All possible combinations of wedges were chosen to optimize coverage of the PTV and to obtain the best planning, a minimum of two and a maximum of four tangential fields in different wedges and energies were used. Gantry angles ranged from 301 to 312 for the medial fields and from 114 to 135 for the lateral fields for patients treated on the left side. Dose volume histograms of the PTV and OAR of the 3D-CRT plans were generated using mean doses received by D 98, D 2, of the breast volume and the mean volumes that received, V 95, V 100, V 107 of the doses and dose parameters compared. The dose homogeneity index (DHI) and the conformity index (CI) were defined as follows: The Homogeneity index (HI) was defined as the fraction of the PTV with a dose between 95% and 107% of the prescribed dose (V 95% -V 107% ). DHI = (D 2 -D 98 ) D pres x100% where, D 98 is the dose received by 98% of the target volume on the c-dvh; D 2 is the dose received by 2% of the target volume on the c-dvh; D pres is the prescribed dose. The DHI should be less than 15 for an acceptable plan and lower DHI values indicate a more homogeneous dose distribution. However, CI was defined as the fraction of the PTV surrounded by the reference dose (V 95% ) multiplied by the fraction of the total body volume covered by the reference PTV dose [(PTV 95% PTV) (PTV 95% V 95% )]. The CI values ranged from 0-1. A higher CI value indicates higher dose conformity to the target. RESULTS AND DISCUSSION In this study, the dosimetric outcomes of different 3DCRT plans in treating the left breast were investigated. The dosimetric comparisons of the treatment volume for the three planning techniques are shown in (Table 2). Mollah et. al. Table 2: Summary of Dosimetric values of the treatment volumes for the three 3DCRT planning methods All the three plans, M1, M2 and M3, achieved comparable good dose coverage, delivering prescribed dose more than 95% to > 95% of the breast PTV. In all these methods, 105% of dose (hot regions) was observed in less than 5% of the target volume. Mean volume of PTV breast receiving 105% was 2.5% (range 0-7.8%) for M1, 2.1% for M2, and 2.8% for M3. In order to identify the most favourable planning method for PTV coverage, different 3DCRT planning was compared using V 95 criteria shows a comparison of the three planning methods on the proportion of the PTV receiving 95% of the prescribed dose, it can be seen that the proportion of PTV receiving 95% of the prescribed dose appeared M2 planning (98.5%) compared with the M1 (97.8%) and M3 (98.2%). The M2 planning method gave more consistency in terms of average coverage. In all cases of the plans, there was at least 95% coverage of the 95% isodose. This would seem to suggest that different 3DCRT plans in these cases would give a good homogenous dose distribution. M2 plans would give a much more homogenous dose distribution (Figure 3). Figure 3: Typical TPS dose distribution for 3DCRT plans for prescription dose and 90 % dose level for left breast. 111

Dosimetric Comparison of Different 3DRCT Bangladesh J. Nucl. Med. Vol. 17 No. 2 July 2014 The DHI in M2 3DCRT method was found to be average 12.2 it was slightly better than M1 and M3 3DCRT as average value of 12.6 and 12.3 respectively. The CI was in M2 3DCRT (0.96) and better than M1 (0.95) and M3 (0.94) 3DCRT planning methods. Figure 4 shows the DVH comparison between the three methods. The values obtained in this study in three different 3DCRT planning were similar to the literature, although the superiority of single isocenter use could not be clearly demonstrated (6, 9). Figure 4: DVH curves for PTV, ipsilateral lung and heart for different 3DCRT plans The average dosimetric characteristics of the OAR for the three planning techniques are presented in Table 3. The mean volume for V 20 lung doses were 19, 16 and 13% for the different 3DCRT planning respectively. It shows that M1 method contributes a little more lung dose at the lower values than the other M2 and M3 3DCRT planning methods. The Heart V 30 was measured for each of the planning methods. It can be seen that the M2 results showed a reduction of the cardiac V 30 dose 4% versus 7% for M1 and mean heart dose 1350 cgy versus 1400 cgy for M2 and M1 3DCRT planning methods, however M3 plan results showed increase of minimal heart dose, mean 1350 cgy in M2 plan versus 1400 cgy in M1 planning method, when analyzed for dose-volume parameters. 112 Table 3: Doses to Organs at Risk (OAR) for different 3DCRT planning methods. CONCLUSION In this study, different dosimetric parameters of PTV as well as OAR were analyzed for different 3DCRT plans of left breast site. All 3DCRT plans are dosimetrically feasible for treating the left breast as a whole PTV, in terms of both PTV coverage and normal tissues sparing. All CI and DHI values are within acceptable limits. Based on these results, the application of single isocenter for 3DCRT technique in left breast cancer provides slightly more advantages especially in PTV and OAR dosages. REFERENCES 1. World health statistics 2010. World Health Organization 2011. Available from URL: http://www.who.int/whosis/whostat/en_whs10_ful l.pdf. 2. Schubert LK, Gondi V, Sengbusch E, Westerly DC, Soisson ET, PaliwalBR, Mackie TR, Mehta MP, Patel RR, Tome WA, Cannon GM. Dosimetric comparison of left-sided left breast irradiation with 3DCRT, forward-planned IMRT, inverse-planned IMRT, helical tomotherapy, and topotherapy. Radiother Oncol 2011; 100:241-246. 3. Lee JW, Hong S, Choi KS, Kim YL, Park BM, Chung JB, Lee DH,Suh TS. Performance evaluation of fieldin-field technique for tangential breast irradiation. Jpn J Clin Oncol 2008; 38:158-163. 4. Fong A, Bromley R, Beat M, Vien D, Dineley J, Morgan G. Dosimetric comparison of left-sided left breast irradiation with 3DCRT, forward-planned IMRT, inverse-planned IMRT, helical tomotherapy, and topotherapy. J Med Imaging Radiat Oncol 2011; 100:241-246.

Bangladesh J. Nucl. Med. Vol. 17 No. 2 July 2014 Mollah et. al. 5. Ohashi T, Takeda A, Shigematsu N, Fukada J, Sanuki N, Amemiya A, Kubo A. Dose distribution analysis of axillary lymph nodes for three dimensional conformal radiotherapy with a field-infield technique forbreast cancer. Int J Radiat Oncol Biol Phys 2009; 73:80-87. 6. Van Beek S, De Jaeger K, Mijnheer B, Van Vliet- Vroegin deweij C. Evaluation of a single-isocenter technique for axillary radiotherapy in breast cancer. Med Dosim 2008; 33:191-198. 7. Rudat V, Alaradi AA, Mohamed A, Ai-Yahya K, Altuwaijri S. Tangential beam IMRT versus tangential beam 3D-CRT of the chest wall in postmastectomy breast cancer patients: a dosimetric comparison. Radiat Oncol 2011; 6:26-31. 8. Fontanilla HP, Woodward WA, Lindberg ME, Kanke JE, Arora G, Durbin RR,Yu T-K, Zhang L, Sharp HJ, Strom EA. Current clinical coverage of Radiation Therapy Oncology Group-defined target volumes for post mastectomy radiation therapy. Practical Radiation Oncology 2012, 2(3):201 209. 9. Klein EE, Taylor M, Michaletz-Lorenz M, Zoeller D, Umfleet W: A mono isocentric technique for breast and regional nodal therapy using dual asymmetric jaws. Int J Radiat Oncol Biol Phys 1994, 28(3):753 760. 10. Sharmin, M.N., Mollah, A. S., Hai, M. A. and Bari, M. Analysis of radiation doses for OAR from tangential breast cancer radiotherapy during 2012-2013 at KYAMCH Cancer Center, Proceedings of the Bangladesh Cancer Congress, 22-23 August 2014, Dhaka, Bangladesh. 11. Prescribing, Recording and Reporting Photon Beam Therapy (Supplement to ICRU Report 50), ICRU Report-62, 1999, URL: http://www.icru.org/home/reports/prescribingrecording-and-reporting-photon-beam-therapyreport-62. 12. Prescribing, Recording, and Reporting Photon Beam Therapy, ICRU Report-50, 1993. URL: http://www.icru.org/home/reports/prescribi ng-recording-and-reporting-photon-beamtherapy-report-50. 113