One of the most exciting developments in ophthalmic

Similar documents
CLINICAL SCIENCES. Repeatability and Reproducibility of Fast Macular Thickness Mapping With Stratus Optical Coherence Tomography

Diabetic Retinopathy Clinical Research Network

Research Article Comparison of Central Macular Thickness Measured by Three OCT Models and Study of Interoperator Variability

Advances in OCT Murray Fingeret, OD

Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems

Cirrus TM HD-OCT. Details define your decisions

Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography

Cirrus TM HD-OCT. Details defi ne your decisions

Journal Articles: Ophthalmology

NIH Public Access Author Manuscript JAMA Ophthalmol. Author manuscript; available in PMC 2013 September 10.

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Optical Coherence Tomography Fast versus Regular Macular Thickness Mapping in Diabetic Retinopathy

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Comparison of Spectral/Fourier Domain Optical Coherence Tomography Instruments for Assessment of Normal Macular Thickness

Citation. As Published Publisher. Version

Structural examina.on: Imaging

AperTO - Archivio Istituzionale Open Access dell'università di Torino

Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography

Optical coherence tomography in diabetic macular edema: patterns and related risk factors

Macular Thickness Measurement via Heidelberg Spectralis SD-OCT in Pediatric Patients

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

R&M Solutions

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Mark Dunbar: Disclosure

8/6/17. Disclosures Aerie Pharmaceuticals Alcon BioTissue Diopsys Optovue Shire

Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography

PRIMUS 200 from ZEISS The essential OCT

Ganglion cell complex scan in the early prediction of glaucoma

Georgos Mylonas, Christian Ahlers, Panagiotis Malamos, Isabel Golbaz, Gabor Deak, Christopher Schütze, Stefan Sacu, Ursula Schmidt-Erfurth

PRIMUS 200 from ZEISS The essential OCT

History/principles of the OCT What does the normal retinal OCT look like Vitreal disorders Retinal/RPE disorders Choroidal disorders

Hyperreflective foci (HFs) have been frequently observed

Citation BioMed Research International, 2015, v. 2015, article no Creative Commons: Attribution 3.0 Hong Kong License

Clinical Study Choroidal Thickness in Eyes with Unilateral Ocular Ischemic Syndrome

Dehiscence of detached internal limiting membrane in eyes with myopic traction maculopathy with spontaneous resolution

How SD-OCT Is Changing Our View of DME

Does blood pressure affect macular thickness in healthy individuals? And is this altered by type two diabetes mellitus?

Flore De Bats, 1 Benjamin Wolff, 2,3 Martine Mauget-Faÿsse, 2 Claire Scemama, 2 and Laurent Kodjikian Introduction

A Treat and Extend Regimen Using Ranibizumab for Neovascular Age-Related Macular Degeneration

OtticaFisiopatologica

NIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2010 April 29.

Age-related macular degeneration (AMD) is one of the leading

The Measure of Confidence

Choroidal Mapping; a Novel Approach for Evaluating Choroidal Thickness and Volume

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Macular Thickness by Age and Gender in Healthy Eyes Using Spectral Domain Optical Coherence Tomography

Comparison of retinal thickness measurements of normal eyes between topcon algorithm and a graph based algorithm

Andrew J. Barkmeier, MD; Benjamin P. Nicholson, MA; Levent Akduman, MD

Optical Coherence Tomography Grid Decentration and Its Effect on Macular Thickness Measurements

HHS Public Access Author manuscript Ophthalmic Surg Lasers Imaging Retina. Author manuscript; available in PMC 2016 January 14.

Comparison of Geographic Atrophy Measurements from the OCT Fundus Image and the Sub-RPE Slab Image

OCT in Diabetic Macular Edema and its Correlation with Flourescein Angiography

Optical Coherence Tomography (OCT) in Uveitis Piergiorgio Neri, BMedSc, MD, PhD Head Ocular Immunology Unit

Ultrahigh Speed Imaging of the Rat Retina Using Ultrahigh Resolution Spectral/Fourier Domain OCT

Identifying the Boundaries of Retinal Pigment Epithelial Detachments Using Two Spectral-Domain Optical Coherence Tomography Instruments

OCT Angiography in Primary Eye Care

Diabetic retinopathy accounts for much of the visual impairment

Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)

Optical Coherence Tomography: Pearls for the Anterior Segment Surgeon Basic Science Michael Stewart, M.D.

Case Report Peripapillary Intrachoroidal Cavitation in Myopia Evaluated with Multimodal Imaging Comprising (En-Face) Technique

Intraretinal Segmentation on Fourier Domain Optical Coherence Tomography

Efficacy of Anti-VEGF Agents in the Treatment of Age-Related Macular Degeneration

Moving forward with a different perspective

OCT Assessment of the Vitreoretinal Relationship in CSME

Spectral-domain Optical Coherence Tomography Imaging of Age-related Macular Degeneration

Study of clinical significance of optical coherence tomography in diagnosis & management of diabetic macular edema

OCT Interpretation in Retinal Disease

Research Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography

Assessment of Artifacts and Reproducibility across Spectral- and Time-Domain Optical Coherence Tomography Devices

Optical Coherence Tomography in Diabetic Retinopathy. Mrs Samantha Mann Consultant Ophthalmologist Clinical Lead of SEL-DESP

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Ophthalmology Department, Lozano Blesa University Hospital, c/ San Juan Bosco 15, Zaragoza, Spain 2

Optical Coherence Tomography (OCT)

ZEISS AngioPlex OCT Angiography. Clinical Case Reports

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Course # Getting to Know Your OCT

Retinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence Tomography

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Retinal vein occlusion (RVO) is a vascular disease

Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD

This is the author s version of a work that was submitted/accepted for publication in the following source:

RETINAL NERVE FIBER LAYER

Optical coherence tomography (OCT) is a new noninvasive

Optical Coherence Tomography-Measured Nerve Fiber Layer and Macular Thickness in Emmetropic, High-Myopic and High-Hyperopic Eyes

Corporate Medical Policy

Posterior Segment Age-related Macular Degeneration

In its initial report, the Early Treatment Diabetic Retinopathy. A Severity Scale for Diabetic Macular Edema Developed from ETDRS Data

Optical coherence tomography (OCT) is a relatively new noninvasive. The Use of Optical Coherence Tomography in Neurology DIAGNOSTIC UPDATE

Clinical Study Spectral Domain OCT: An Aid to Diagnosis and Surgical Planning of Retinal Detachments

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

NIH Public Access Author Manuscript Ophthalmic Surg Lasers Imaging Retina. Author manuscript; available in PMC 2014 June 24.

Title: OCT Analysis Workshop: Interpretation of OCT printouts

Optical coherence tomography of the vitreoretinal interface in macular hole formation

A spectral-domain OCT study of formerly premature children. Prat Itharat MD May 30, 2008 Vanderbilt Eye Institute Preceptor: Dr.

Individual A-Scan Signal Normalization Between Two Spectral Domain Optical Coherence Tomography Devices

Acquired vitelliform detachment in patients with subretinal drusenoid deposits (reticular pseudodrusen)

Swept-Source OCT Angiography: SS OCT Angio TM

Evaluation of Changes of Macular Thickness in Diabetic Retinopathy after Cataract Surgery

VISUAL ACUITY OUTCOMES OF RANIBIZUMAB TREATMENT IN PATHOLOGIC MYOPIC EYES WITH MACULAR RETINOSCHISIS AND CHOROIDAL NEOVASCULARIZATION

Transcription:

Macular Thickness Measurements in Healthy Eyes Using Six Different Optical Coherence Tomography Instruments Ute E. K. Wolf-Schnurrbusch, 1,2 Lala Ceklic, 1,3 Christian K. Brinkmann, 1,2 Milko E. Iliev, 1 Manuel Frey, 2 Simon P. Rothenbuehler, 2 Volker Enzmann, 1 and Sebastian Wolf 1,2 PURPOSE. To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements. METHODS. Six different OCT instruments (Stratus OCT [Carl Zeiss Meditec, Inc. Dublin, CA], SOCT Copernicus [Reichert/ Optopol Technology, Inc., Depew, NY], Spectral OCT/SLO [Opko/OTI, Inc., Miami, FL], RTVue-100 [Optovue Corp., Fremont, CA], Spectralis HRA OCT [Heidelberg Engineering, Inc., Heidelberg, Germany], and Cirrus HD-OCT [Carl Zeiss Meditec, Inc.]) were used to assess CRT in both eyes of healthy subjects. Measurements were performed in two different sessions on the same day with each of the systems. From these measurements, the mean CRT was calculated. For the assessment of the intersession reproducibility of the instruments, we calculated the coefficient of the variation of test retest variation. RESULTS. Twenty healthy subjects were included in the study. Compared with the Stratus OCT all spectral OCT instruments showed significantly higher CRTs. The Spectralis HRA OCT and Cirrus HD-OCT showed similar CRT values but significantly higher values than did all other instruments. The coefficients of variation for repeated measurements was 3.33% for the Stratus OCT, 0.46% for the Spectralis HRA OCT, 3.09% for the Cirrus HD-OCT, 2.23% for the OCT/SLO, 2.77% for the RTVue-100 OCT, and for the SOCT 3.5%, respectively. DISCUSSION. The six OCT systems provided different results for CRT. The measurements with the Stratus OCT showed the lowest thicknesses, whereas those with the Cirrus HD-OCT and Spectralis HRA OCT yielded the highest ones. These discrepancies can be explained by the differences in the retinal segmentation algorithms used by the various OCT systems. Whereas the Spectralis HRA OCT and Cirrus HD-OCT include the RPE layer in the retinal segmentation, the other instruments do not. The data imply that the different OCT systems cannot be used interchangeably for the measurement of mac- From the 1 Universitätsklinik für Augenheilkunde and the 2 Bern Photographic Reading Center, Inselspital, University of Bern, Bern, Switzerland; and the 3 Klinicki Centar Isotocno Sarajevo, Dobrosava Jevdjevica, RS-Bosnia and Herzegovina. Submitted for publication October 6, 2008; revised November 30 and December 17, 2008, and January 22, 2009; accepted April 29, 2009. Disclosure: U.E.K. Wolf-Schnurrbusch, None; L. Ceklic, None; C.K. Brinkmann, None; M.E. Iliev, None; M. Frey, None; S.P. Rothenbuehler, None; V. Enzmann, None; S. Wolf, None The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked advertisement in accordance with 18 U.S.C. 1734 solely to indicate this fact. Corresponding author: Sebastian Wolf, Universitätsklinik für Augenheilkunde, Inselspital, University of Bern, Freiburgstrasse 14, CH- 3010 Bern, Switzerland; sebastian.wolf@insel.ch. ular thickness. (Invest Ophthalmol Vis Sci. 2009;50:3432 3437) DOI:10.1167/iovs.08-2970 One of the most exciting developments in ophthalmic imaging is probably optical coherence tomography (OCT), which was introduced in 1991. 1 4 Being a part of clinical practice since 1995, OCT may evolve as a noninvasive investigation that replaces or is complementary to fluorescein angiography. Future therapeutic options are in discussion. 2,3,5 7 Today, the conventional time-domain OCT image of the posterior pole centered on fixation is well understood. A hyperreflective (color coded red) line in the midthickness of the trace is a central reference point and represents the retinal pigment epithelium (RPE)-choriocapillaris complex. Posterior to this structure, the signal weakens due to attenuation. Anterior to the RPE/choriocapillaris, the retina is seen as a layer of lower reflectivity (color coded green-yellow). Foveal depression and the optic disc are clearly visible in physiological conditions. Descriptions of the different intraretinal layers in OCT images have been published in detail. Thoth et al. 8 described the nerve fiber layer as a hyperreflective layer, usually visible where the layer is thickest: nasal to the fovea in horizontal sections and superior and inferior to the fovea in vertical sections. 8 Others (e.g., Chauhan and Marshall 9 ) have questioned this description, and it is probably only acceptable for describing retinal thickness as the distance between the hyperreflective layer representing the RPE/photoreceptor complex and the vitreoretinal interface. 9 In these cases, normal foveal thickness measured by time-domain OCT is approximately 210 m. 10,11 The posterior hyaloid interface may be visible as a thin, hyperreflective (color coded red-white) structure against the dark hyporeflective vitreous cavity. However, this layer is only discernible if there is vitreoretinal separation, 8 and it has to be mentioned that there is still controversy regarding the correlation of the outer OCT hyperreflective bands with anatomic findings. In recent years, the conventional time-domain OCT has played an important role as a diagnostic tool in monitoring patients with macular disorders. It is used in various studies to assess morphologic changes during therapy by analyzing macular thickness. 12 14 When observing patients over time, it is important to assess changes in macular thickness correctly and to be able to compare baseline findings with follow-up measurements. In this context, the widely used OCT-3 Stratus model, released in 2002, and its updated software version 4.0 have well-known limits. The conventional time-domain OCT often produces false macular thickness maps in patients with macular disorders, because the retinal thickness algorithm is not always able to identify the inner border of the RPE and/or the inner limiting membrane (ILM). One reason for this deficiency may be the severe morphologic changes in the retina and RPE of these patients. Investigative Ophthalmology & Visual Science, July 2009, Vol. 50, No. 7 3432 Copyright Association for Research in Vision and Ophthalmology

IOVS, July 2009, Vol. 50, No. 7 Macular Thickness Measurements Using Different OCT Systems 3433 TABLE 1. Technical Details of the OCT Instruments Instrument Company Axial Resolution ( m) Scan Speed (Scans/s) Stratus OCT Carl Zeiss Meditec, Inc., Dublin, CA 8 10 m 600 Spectralis HRA OCT Heidelberg Engineering, Inc., Heidelberg, Germany 4 6 m 40,000 Spectral OCT/SLO Opko/OTI, Inc., Miami, FL 5 6 m 27,000 Cirrus HD-OCT Carl Zeiss Meditec, Inc. 5 m 27,000 SOCT Copernicus Reichert/Optopol Technology, Inc., Depew, NY 4 6 m 25,000 RTVue-100 Fourier-Domain OCT Optovue Corporation, Freemont, CA 5 m 26,000 Current advances (e.g., the introduction of Fourier analysis; spectral OCT) have made high resolution and fast scanning speed possible, 15 17 with resolution being up to five times higher and imaging speed up to 60 times faster than in conventional time-domain OCT. 16 High-resolution OCT makes differentiation of as many as 11 structural characteristics within the retina 15,18 possible. The purpose of our study was to report macular thickness measurements in healthy eyes by using different commercially available OCT instruments and to evaluate the reproducibility of test results with these instruments. In addition, we analyzed differences in mean macular thickness measurements for each of the different OCT instruments. We believe that this should be the first step in analyzing macular thickness measurements. The next most important step is analyzing patients with different retinal diseases to assess the limits and errors of OCT thickness measurements. From the OCT examinations, thickness maps were calculated with the built-in analysis software of the OCT. For analysis, the mean and standard deviations was calculated for the CRT measured with each of the six different instruments, separately for the right and left eyes. Differences between the eyes were assessed by the paired Student s t-test. To assess the differences between the instruments, we used only measurements of the right eye of each subject. The paired Student s t-test was used to compare the CRT measurements from all instruments. All P-values were adjusted for multiple testing according to Holm. 19 For the assessment of intersession repeatability, we recalculated the coefficient of variation (CV) from equation 1 to determine test retest variation. 20 TABLE 2. Description of Acquisition Protocols for Each OCT Instrument METHODS Subjects with clear media in both eyes and normal retinal status were recruited for our study. Inclusion criteria were an age of 18 years or older, best corrected visual acuity (BCVA) of 20/20, refractive error of 3 D, and no history or evidence of either systemic or ophthalmic disease. In eligible subjects, both eyes were studied. Before OCT examination, all subjects underwent a complete ophthalmic examination including a detailed medical and ocular history, BCVA with ETDRS charts, binocular ophthalmoscopy, and color fundus photography (FF 450 plus; Carl Zeiss Meditec, Jena, Germany). Six different OCT instruments (Table 1) were used to assess central retinal thickness (CRT, mean thickness in the central 1000- m diameter area). Each subject underwent two acquisition sessions on each of the six OCT instruments within 2 hours on the same day. In the first series, each subject was taken through one acquisition session for both eyes (first the right eye then the left) with each instrument used in random order. Thereafter, a second series of acquisition sessions was undertaken in the same order. The OCT instruments were operated by the same trained operator. Only OCT scans that were of sufficient quality (signal 50% of maximum strength, absence of imaging artifacts, or distortions) were used. Replicates were only taken if the OCT scans were of insufficient quality. We attempted to use similar acquisition protocols on each instrument (Table 2), but especially for the OCT-3 Stratus, no volume scan protocol is available. Therefore, we used the Fast Macular Thickness map protocol. For acquisition of the volume scans with the Spectralis HRA OCT the unique feature of real-time averaging of line scans was used. Six scans were averaged to produce one line scan to be used as the volume scan. Before examination, the pupil of the study eye was dilated to at least 6 mm diameter with drops containing 0.5% tropicamide and 2.5% phenylephrine. The procedure was similar for each of the instruments. After the acquisition protocol and scan procedure were explained to them in detail, the subjects were placed in front of the OCT instrument and asked to fixate on an internal fixation target. After the focus was adjusted and a good central fixation obtained, the scanning process was initiated. Instrument Stratus OCT Spectralis HRA OCT Spectral OCT/SLO Cirrus HD-OCT SOCT Copernicus RTVue-100 Fourier- Domain OCT Acquisition Protocol Fast macular thickness Six radial scans (6 lines; 128 A-scans per line) Scan area: 6-mm diameter circle Acquisition time for scan: 1.5 seconds Software version 4.0 Volume scan 512 49-scan pattern (49 lines; 512 Scan area: 6 6mm Acquisition time for scan: 5.0 seconds Factor for scan averaging: 6 Software version 3.2 3D retinal topography 512 64-scan pattern (64 lines; 512 Scan area: 9 9mm Acquisition time for scan: 1.5 seconds Software version 2.0 Macular cube 512 128-scan pattern (128 lines; 512 Scan area: 6 6mm Acquisition time for scan: 2.5 seconds Software version 2.0 3D scan 637 50-scan pattern (50 lines; 637 Scan area: 6 6mm Acquisition time for scan: 1.5 seconds Software version 1.2 Macular map 512 101-scan pattern (101 lines; 512 Scan area: 5 5mm Acquisition time for scan: 2.0 seconds Software version 2.0

3434 Wolf-Schnurrbusch et al. IOVS, July 2009, Vol. 50, No. 7 TABLE 3. CRT Obtained by Each Instrument Instrument CRT Right Eye CRT Left Eye Stratus OCT 213 19 212 20 Spectralis HRA OCT 288 16 290 15 Spectral OCT/SLO 243 25 245 24 Cirrus HD-OCT 276 17 277 21 SOCT Copernicus 246 23 250 23 RTVue-100 245 28 249 24 All data are expressed as mean micrometers SD. n 20. (x 1 i x 2 i ) 2 2 n cv 1 x i n where x i 1 is the result from the first series, x i 2 is the result from the second series, and n is the number of eyes. This study was performed with the informed consent of the participants. It was conducted under a protocol approved by the local institutional review board, in accordance with the ethics stated in the Declaration of Helsinki (1964) and with the recommendations of the local ethics committee. RESULTS Forty eyes of 20 healthy subjects (11 women, 9 men) aged from 25.0 to 63.0 years (37.1 12.8) were included in the study. The refractive error ranged between 2.0 and 1.0 D (mean, 0.34 0.82 D). Measurement of CRT was possible in all 40 eyes. All the OCT scans showed signal strength 70% of maximum strength, and no errors in the layer segmentation were observed. Table 3 shows the mean CRT separated for right and left eyes for all six instruments. No significant differences in CRT were found between the right and left eyes. Table 4 presents the comparison of the measurements obtained with the six instruments (significances above the diagonal and differences below). The differences in CRT ranged between 2 and 77 m. Compared with the time-domain instrument Stratus OCT, all spectral OCT instruments showed significantly higher CRTs. The Spectralis HRA OCT and Cirrus HD- OCT showed similar CRTs but significantly higher ones than all the other instruments. In addition, for comparison of CRT measurements on the different OCT machines, Bland Altman plots were calculated (Fig. 1). To quantify the intersession reproducibility of the instruments, we performed repeated measurements. Table 4 shows the CRTs for the first and second measurements, as well as the intersession repeatability (CV) for all instruments. The intersession repeatability (CV) was 3.33% for the Stratus OCT, 0.46% (1) for the Spectralis HRA OCT, 3.09% for the Cirrus HD-OCT, 2.23% for the OCT/SLO, 2.77% for the RTVue-100 OCT, and 3.5% for the SOCT. Compared with the Stratus OCT, only the Spectralis HRA OCT showed a significantly lower variation between the two measurements. All other instruments had similar reproducibility (Table 5). DISCUSSION In this study, we compared the measurements of CRT in healthy subjects by six different commercially available OCT instruments. These included one time-domain OCT and five spectral OCT systems. In our study, the measurements of CRT in a group of healthy subjects ranged between 212 19 and 289 16 m. Because only healthy subjects with good fixation were included, the OCT scans were of excellent quality and the segmentation of retinal layers showed no errors. In patients with retinal diseases, this may be different and could include additional variability. The time-domain results differ significantly between the different OCT instruments. The CRT measurements can be subdivided into three different range groups. The Stratus OCT produced the lowest CRT; the SOCT Copernicus, Spectral OCT/SLO, and the RTVue-100 produced midrange values; and the Spectralis HRA OCT and Cirrus HD-OCT produced the highest ones. The differences between the instruments include different methods of scan acquisition, of segmentation of the retinal borders, and of sampling the measurement points and probably different estimates for the optical indices of the retina. In addition, there are important differences between the algorithms for alignment and registration of the OCT scans. The acquisition protocols differ substantially between the instruments (Table 2). The Stratus OCT system uses only six radial lines with a total of 768 A-scans to produce a thickness map with a diameter of 6 mm. Because the density of the measuring points is dependent on the distance from the center, only measurements inside the central 1000- m diameter area are based on a sufficient number of A-scans (128 A scans). The other instruments use rectangular scan patterns resulting in a uniform density of A-scans within the scan area. However, the number of A-scans per square millimeter differs considerably among the instruments. The density varies between 1428 A-scans/mm 2 (Cirrus HD-OCT) and 524 A-scans/mm 2 (Spectral OCT/SLO). The differences in the number of A-scans per square millimeter may have an influence on the CRT, but this influence can only be evaluated by repeated measurements with the same instrument with different scan densities in a future study. The acquisition time of the volume scans ranges between 1.5 and 5.0 seconds. The longest acquisition time was observed with the Spectralis HRA OCT. This long acquisition time is due to the real-time averaging feature of the system. But the averaging feature is combined with a real-time tracking TABLE 4. Comparison of Measurements Stratus OCT Spectralis HRA OCT Spectral OCT/SLO Cirrus HD-OCT SOCT Copernicus RTVue-100 Stratus OCT P 0.01 P 0.01 P 0.01 P 0.01 P 0.01 Spectralis HRA OCT 77 P 0.01 NS P 0.01 P 0.01 Spectral OCT/SLO 32 45 P 0.01 NS NS Cirrus HD-OCT 65 12 33 P 0.01 P 0.01 SOCT Copernicus 37 40 5 28 NS RTVue-100 35 42 3 30 2 Above the diagonal, the P values (paired Student s t-test, adjusted for multiple testing) for the differences between the mean measurements are displayed. Below the diagonal, the differences between the measurements are displayed in micrometers. Note that Stratus OCT measurements were significantly different from those of all other instruments.

IOVS, July 2009, Vol. 50, No. 7 Macular Thickness Measurements Using Different OCT Systems 3435 FIGURE 1. Bland Altman plots for the comparison of the Stratus OCT versus (A) the Cirrus HD-OCT, (B) the Spectralis HRA OCT, (C) the RT- Vue-100, (D) the Spectral OCT/SLO, and (E) the SOCT Copernicus. TABLE 5. First and Second Measurements and Intersession Repeatability Instrument CRT 1 CRT 2 CV (%) Stratus OCT 212 19 210 16 3.33 Spectralis HRA OCT 289 16 289 18 0.46 Spectral OCT/SLO 244 24 244 24 2.23 Cirrus HD-OCT 277 19 276 18 3.09 SOCT Copernicus 249 23 251 26 3.50 RTVue-100 247 26 248 26 2.77 Data are expressed as the mean CRT in micrometers SD. system for eye movements, and so the long acquisition time had no negative influence on repeatability. The segmentation software of all the instruments identifies different hyperreflective structures in each line scan. The segmentation of the inner retinal border is not different among the instruments. All instruments identify the vitreoretinal interface as the inner retinal border. The segmentation of the outer retinal border differs among the instruments significantly. The Stratus OCT system image the outer retinal layers (RPE-photoreceptor complex) as two hyperreflective bands. The segmentation software of the Stratus OCT system uses the inner hyperreflective band for segmentation. The new spectral OCT systems image the outer retinal layers typically as three hyperreflective bands. The most inner of these hyperreflective bands has the lowest reflectivity and cannot be imaged with the Stratus OCT system. The bands may correspond to the external limiting membrane, the junction of the photoreceptor outer segments (OS) and inner segments (IS), and the RPE. The SOCT Copernicus, Spectral OCT/SLO, and RTVue-100 use the second inner hyperreflective band as the outer border of the retina. The Cirrus HD-OCT and the Spectralis HRA OCT identify the most outer reflective band as the outer border of the retina (Fig. 2). Thus, the Stratus OCT system would be expected to yield CRTs that are lower than the ones from all other instruments, whereas Cirrus HD-OCT and Spectralis HRA OCT system should yield the highest measurements. Some of the instruments allow manual correction of the automated segmentation. In this study, we did not use the manual adjustment to change the segmentation layers. It may be possible to obtain similar results by adjusting the segmentation, but this was not the subject of our study. In this study, we also measured and compared the repeatability indices of the Stratus OCT, SOCT Copernicus, Spectral OCT/SLO, and RTVue-100, Spectralis HRA OCT, and Cirrus HD-OCT systems within the same population of healthy subjects. For OCT scans obtained by the same experienced operator with adequate signal strength and accurate segmentation, all systems produced measures that reflected low variance. The CV of repeated measurements ranged between 0.46% with the

3436 Wolf-Schnurrbusch et al. IOVS, July 2009, Vol. 50, No. 7 Spectralis HRA OCT and 3.5% with the SOCT Copernicus system. The high repeatability of the Spectralis HRA OCT measurements is most probably related to the unique feature of the system that allows eye tracking during the scanning process as well as automatic recognition of the exact same scan location for follow-up examination. By using this feature for all follow-up scans with the Spectralis HRA OCT, we could minimize extrinsic factors, such as patient fixation and the operator s ability to consistently place the macular grid over the same points during each scan. Currently, several studies on the reproducibility of timedomain OCT systems but only scant data on reproducibility of spectral domain OCT systems have been published. In 2001, Massin et al. 7 reported results using the first commercially available time-domain OCT. In their study, retinal thickness measurements in nine ETDRS areas of 10 healthy eyes were analyzed. Interclass correlation coefficients ranged from 0.89 to 0.99. In addition, they tested reproducibility in patients with clinically significant macular edema. In these diabetic patients, the interclass correlation coefficients were always larger than 0.98 and the reproducibility was 6%. Muscat et al. 21 and Koozekanani et al. 22 also demonstrated good reproducibility, with overall coefficients between 1% and 2% and an expected variation of less than 11 m between measurements. Gürses- Ozden et al. 23 found acceptable reproducibility in healthy subjects. The Stratus OCT measurement yielded a CV of 5.8% using the Fast Macular Thickness scan and a CV of 4.7% using the Radial Line Scan. In 2006, Polito et al. 24 reported CVs from 1.68% to 6.63% in a healthy group and from 4.84% to 8.33% in a diabetic group. A recent study compared macular thickness measurements and their repeatability in the Stratus OCT and the Cirrus HD-OCT system in patients with diabetic macular edema (DME). 25 In addition, a study of healthy subjects comparing the Stratus OCT and the 3D OCT (Topcon, Tokyo, Japan) was performed by Leung et al. 26 We found that all these data on CRT measurement and repeatability were comparable with ours. Beside the CRT measurements, the high resolution of every spectral OCT scan gives important information about the structure of the retina and allows analysis of more layers than do the Stratus OCT scans. In patients with macula disorders, highresolution retinal thickness maps may provide additional information about the stage of the disease and allow more precise comparison of follow-up OCT results with baseline findings. 27 In summary, we found that the OCT systems provided different values for CRT: Measurements with the Stratus OCT showed the lowest values, whereas measurements with the Cirrus HD-OCT and Spectralis HRA OCT yielded the highest ones. These discrepancies were most probably based on differences in retinal segmentation algorithms used by the various OCT systems. These data imply that the different OCT systems cannot be used interchangeably for the measurement of macular thickness. The unique feature of the Spectralis HRA OCT system, which allows automatic recognition of the exact same scan location, resulted in the best intersession reproducibility of measurements. References FIGURE 2. OCT scans from a healthy subject recorded with the Spectral OCT/SLO, the Spectralis HRA OCT, and the Stratus OCT. The images clearly show that the three different instruments use different retinal layers to define the outer border of the retina. 1. Hee MR, Puliafito C, Carlton W, et al. Quantitative assessment of macular edema with optical coherence tomography. Arch Ophthalmol. 1995;113(8):1019 1029. 2. Hee MR, Puliafito CA, Wong C, et al. Quantitative assessment of macular edema with optical coherence tomography. Arch Ophthalmol. 1995;113(8):1019 1029. 3. Puliafito CA, Hee MR, Lin CP, et al. Imaging of macular diseases with optical coherence tomography. Ophthalmology. 1995;102: 217 229. 4. Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science. 1991;254(5035):1178 1181. 5. Barbazetto I, Burdan A, Bressler NM, et al. Photodynamic therapy of subfoveal choroidal neovascularization with verteporfin: fluorescein angiographic guidelines for evaluation and treatment. TAP and VIP report No. 2. Arch Ophthalmol. 2003;121(9):1253 1268. 6. Hee MR. Artifacts in optical coherence tomography topographic maps. Am J Ophthalmol. 2005;139(1):154 155. 7. Massin P, Vicaut E, Haouchine B, Erginay A, Paques M, Gaudric A. Reproducibility of retinal mapping using optical coherence tomography. Arch Ophthalmol. 2001;119(8):1135 1142. 8. Toth CA, Narayan DG, Boppart SA, et al. A comparison of retinal morphology viewed by optical coherence tomography and by light microscopy. Arch Ophthalmol. 1997;115(11):1425 1428. 9. Chauhan DS, Marshall J. The interpretation of optical coherence tomography images of the retina. Invest Ophthalmol Vis Sci. 1999; 40(10):2332 2342. 10. Hee MR, Puliafito CA, Duker JS, et al. Topography of diabetic macular edema with optical coherence tomography. Ophthalmology. 1998;105(2):360 370. 11. Massin P, Erginay A, Haouchine B, Mehidi AB, Paques M, Gaudric A. Retinal thickness in healthy and diabetic subjects measured using optical coherence tomography mapping software. Eur J Ophthalmol. 2002;12(2):102 108. 12. Pieramici DJ, Avery RL. Ranibizumab: treatment in patients with neovascular age-related macular degeneration. Expert Opin Biol Ther. 2006;6(11):1237 1245. 13. Midena E, Segato T, Bottin G, Piermarocchi S, Fregona I. The effect on the macular function of laser photocoagulation for diabetic macular edema. Graefes Arch Clin Exp Ophthalmol. 1992;230(2): 162 165. 14. Regillo CD, Brown DM, Abraham P, et al. Randomized, doublemasked, sham-controlled trial of ranibizumab for neovascular agerelated macular degeneration: PIER Study Year 1. Am J Ophthalmol 2008;145(2):239 248-e235. 15. Ruggeri M, Wehbe H, Jiao S, et al. In vivo three-dimensional high-resolution imaging of rodent retina with spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2007; 48(4):1808 1814. 16. Wojtkowski M, Srinivasan V, Fujimoto JG, et al. Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. Ophthalmology. 2005;112(10):1734 1746. 17. Brinkmann CK, Wolf S, Wolf-Schnurrbusch UE. Multimodal imaging in macular diagnostics: combined OCT-SLO improves thera-

IOVS, July 2009, Vol. 50, No. 7 Macular Thickness Measurements Using Different OCT Systems 3437 peutical monitoring. Graefes Arch Clin Exp Ophthalmol. 2008; 246(1):9 16. 18. Drexler W, Sattmann H, Hermann B, et al. Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography. Arch Ophthalmol. 2003;121(5): 695 706. 19. Holm S. A simple sequentially rejective multiple test procedure. Scand J Statist. 1999;6:65 70. 20. Wolf S, Arend O, Reim M. Measurement of retinal hemodynamics with scanning laser ophthalmoscopy: reference values and variation. Surv Ophthalmol. 1994;38(Suppl):95 100. 21. Muscat S, Parks S, Kemp E, Keating D. Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system. Invest Ophthalmol Vis Sci. 2002;43(2):490 495. 22. Koozekanani D, Roberts C, Katz SE, Herderick EE. Intersession repeatability of macular thickness measurements with the Humphrey 2000 OCT. Invest Ophthalmol Vis Sci. 2000;41(6):1486 1491. 23. Gürses-Ozden R, Teng C, Vessani R, Zafar S, Liebmann JM, Ritch R. Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3). J Glaucoma. 2004;13(3):238 244. 24. Polito A, Del Borrello M, Polini G, Furlan F, Isola M, Bandello F. Diurnal variation in clinically significant diabetic macular edema measured by the Stratus OCT. Retina. 2006;26(1):14 20. 25. Forooghian F, Cukras C, Meyerle CB, Chew EY, Wong WT. Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema. Invest Ophthalmol Vis Sci. 2008;49(10):4290 4296. 26. Leung CK, Cheung CY, Weinreb RN, et al. Comparison of macular thickness measurements between time domain and spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2008;49(11):4893 4897. 27. Wolf-Schnurrbusch UE, Enzmann V, Brinkmann CK, Wolf S. Morphologic changes in patients with geographic atrophy assessed with a novel spectral OCT-SLO combination. Invest Ophthalmol Vis Sci. 2008;49(7):3095 3099.