An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization

Similar documents
Evaluation of the Effect of Temperature Changes on the Dimensional Stability of poly (Vinyl Siloxane) Impression Material.

The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials

Comparison of the accuracy and dimensional stability of interocclusal recording materials - An in- vitro study.

The Effects of Disinfectants on Dimensional Accuracy and Surface Quality of Impression Materials and Gypsum Casts

Professor Dept. of Prosthodontics, Crown and Bridge, Sri Aurobindo College of Dentistry, Indore M.P.

Rahul Nagrath Manesh Lahori Manjari Agrawal

Journal of Clinical and Translational Research; 2018; 4(1): xxx-xxx

Precision. Hydrophilicity. V-Posil. Dimensional stability. Intraoral setting time. Working time. Precision impression material, A-silicone-based

Comparison of Dimensional Accuracy of Four Different Die Materials before and after Disinfection of the Impression: An in vitro Study

Original Research. Matrix impression system Kumar MP et al

Original Research. Absorption of soft lining materials Kumar SK et al

Impressions in fixed partial denture: A review update

Evaluation of Antibacterial Effect and Dimensional Stability of Self-disinfecting Irreversible Hydrocolloid: An in vitro Study

SOLUBILITY OF DIFFERENT SOFT LINING MATERIALS IN DISTILLED WATER, ARTIFICIAL SALIVA AND DENTURE DISINFECTANT SOLUTION

Al-Qarni AA. Dimensional Accuracy of Multiple Pour Cast from

Comparative Evaluation of Dimensional Accuracy and Surface Detail Reproduction of Elastomeric Impression Material when Treated

The Puzzle of OSHA Compliance and Infection Control in the Dental Laboratory. The Puzzle of OSHA Compliance in the Dental Laboratory

Facts About. Express. Penta Putty/ Ultra-Light Body. Vinyl Polysiloxane Precision Impression Materials

Impression for complete dentures is a negative replica of the edentulous ridges and the adjacent supporting structures.

Comparative Evaluation of the Accuracy and Dimensional Stability of Three Interocclusal Recording Materials- An In Vitro Study

A New Category of Impression Material VPES - A Breakthrough Technology

Imprint 3. Technical Data Sheet. VPS Impression Material. Indications. Introduction

A comparative evaluation of three different techniques for single step border molding

IMPRESSION MATERIALS

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

Virtual The hydrophilic precision impression material

Dimensional Stability of Two Polyvinyl Siloxane Impression Materials in Different Time Intervals

Dimensional Accuracy of 2 Irreversible Hydrocolloid Alternative Impression Materials with Immediate and Delayed Pouring

Efficacy of Various Disinfectants on Dental Impression Materials. U Sukhija, M Rathee, N Kukreja, S Khindria, V Singh, J Palaskar

B U J O D. Invited Review IMPLANT IMPRESSIONS SIMPLIFIED. Reddy et al. Vol. 2 Issue-3 Sept

CASE REPORT ABSTRACT INTRODUCTION. AIMS AND OBJECTIVES Aims

Comparison of custom trays and stock trays using polyvinylsiloxane to evaluate linear dimensional accuracy: An in vitro study

Evaluation and Comparison of the Effect of Different Border Molding Materials on Complete Denture Retention: An in vivo Study

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Polyether Impression Material. Technical Product Profile Impregum. L DuoSoft Quick

Impregum Soft. Impregum Soft Quick Step. Technical Data Sheet. Polyether Tray Impression Material. Polyether Tray Impression Material.

Comparison of the surface roughness of gypsum models constructed using various impression materials and gypsum products

DPI Luting Cement. DPI Restorative Cement

Hardness and Surface Detail Reproduction of Gypsum Casts Retrieved from Addition Silicone Impressions Disinfected for Different Time Points

Vin ylsi loxan xane:

JMSCR Vol 04 Issue 10 Page October 2016

Frequent use for the preparation of prosthetic products

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

Evaluation of Bond Strength of Silicone and Acrylic Resin Based Resilient Denture Liners Over A Period of Storage in Water.

Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays

Impregum TM Soft. Polyether Impression Material. Technical Product Profile

IMPRESSION TRAYS. Stainless Steel Edentulous Impression Trays. 73

Effects of disinfection procedures on surface quality of compound impressions and the resultant gypsum casts

Lecture:6 dental material dr. Aseel Mohammed

Double-casting method for fixed prosthodontics with functionally generated path

Community response to noise

FLEXCEED EXCEEDS YOUR EXPECTATIONS

Effect of Intermixing Brands on the Dimensional Accuracy of Master Cast using Putty-wash Impression Technique

DENTAL MATERIALS I SYLLABUS DA INSTRUCTOR: Carrie Johnson CDA, EFDA OFFICE: RCH 201A. OFFICE HOURS: Posted PHONE:

Comparison of Flexural Strength of two Provisional Materials Used In Fixed Prosthodontics -An in Vitro Study.

Research Article Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique

International J. of Healthcare and Biomedical Research, Volume: 04, Issue: 03, April 2016, 83-92

ZEST DANVILLE MATERIALS PERIOSCOPY

and get a Pentamix TM Lite free *

Reproducibility of Interocclusal Recording for Mandibular Removable Partial Denture in Bilateral Distal Extension Cases

Impression for crown and bridge work

IJOCR ABSTRACT INTRODUCTION

Effect of Different Dental Materials on the Surface. Roughness of Acrylic Resin ( A comparative in vitro study )

Linear dimensional changes in plaster die models using different elastomeric materials

Evaluation of Contamination Reduction on Gypsum Casts from Alginate Impressions Disinfected with Four Different Materials

Bond strength test of acrylic artificial teeth with prosthetic base

Survey of Current Materials and Impression Techniques for Complete Dentures among Nepalese Prosthodontists

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

The elastomers for complete denture impression: A review of the literature

No Compromise. digit Power Dispenser. Aquasil Ultra+ Smart Wetting Impression Material

Aquasil. Ultra+ Smart Wetting Impression Material. For Implant Impressions. No Compromise.

2-step. 1-step. Technical Data Sheet. Express 2 Penta Putty Soft

The Effect of Microwave Disinfection on the Dimensional Change of Acrylic Resins.

An evaluation of the hardness of flexible Denture Base Resins

Iresponsible for restoring the natural esthetics and

RelyX Unicem Self-Adhesive Universal Resin Cement Frequently Asked Questions

IMPRESSION PROCEDURES TRAINING MANUAL

DIMENSIONAL STABILITY OF IMPRESSION BODY USING THE SILICONE INDEX TOOTH TRAY IMPRESSION SYSTEM

Honigum Overcoming opposites.

ACOMPARATIVEEVALUATIONOFEASY REMOVALOFDENTALCASTSFROMALGINATE IMPRESSIONSUSINGDIFFERENTBRANDSOF DENTALSTONE-ANINVITROSTUDY

User Manual Complete Prosthetic Kit (CPK)

Study to evaluate the Effect of Silane Treatment and Three Different Woven Fiber Reinforcement on Mechanical Properties of a Denture Base Resin

International Journal of Sciences & Applied Research

Complete denture impressions

DENTAL MATERIALS STUDY GUIDE

Lect. 14 Prosthodontics Dr. Osama

EXAIMPLANT HYDROPHILIC VINYL POLYSILOXANE IMPRESSION MATERIAL (FOR DENTAL IMPLANTS) RECOMMENDED INDICATIONS CONTRAINDICATIONS

A BAG OF TRICKS USING SECTIONAL DENTURES: PROSTHETIC REHABILITATION OF COMPLETELY EDENTULOUS PATIENT WITH MICROSTOMIA-A CASE REPORT

Handling efficiency of autopolymerized resin applied using the brush-on technique

Effect of Thickness and Recycling on Transverse Strength of Relined Acrylic Resin Denture

Core practical 14: Investigate the effect of gibberellin on the production of amylase in germinating cereals using a starch agar assay

Nagri D et al. Linear occlusion and Neutral Zone recording for severely resorbed ridges

eliminate interlocking with new QUick Up method

Administrative - Master Syllabus COVER SHEET

MATERIALS AND METHODS

Impression Materials and Storage Time Influence on Cast Models Accuracy

The Effect of Outdoor Weathering on Color Stability of Silicone and Acrylic Resin, Pigments A Comparative Evaluation: An in vitro Study

VIP Partner Laboratory (PL) Process Flow

mono GHENESYL time mint flavour monophase addition curing polyvinylsiloxane silicone 40% MINIMUM TIME IN MOUTH

Transcription:

Original Article An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization Poonam K. Khinnavar, B. H. Dhanya Kumar, D. B. Nandeeshwar Department of Prosthodontics, Bapuji Dental College and Hospital, Davangere, Karnataka, India Abstract Objectives: This study was planned to evaluate the dimensional stability of elastomers during cold sterilization or immersion disinfection and also to evaluate the same, along with acrylic resin trays which are used in clinical practice. Materials and Methods: A study mold according to revised American Dental Association. Specification no. 19 was used. Polyether, polyvinyl siloxane (PVS) (heavy body), PVS (regular body) and Hydrophilic addition reaction silicon (medium body) were selected for study. 2% glutaraldehyde and 0.525% sodium hypochlorite were the disinfectants used. The study was divided into group I and group II. In group I study, 24 specimens of each impression material were prepared. Eight immersed in 2% glutaraldehyde, eight in 0.525% sodium hypochlorite and rest eight allowed to dry bench cure. After 16 h, the specimens measured under Leica WILD stereomicroscope and dimensions compared with master die. In group II study, 24 specimens of the material with the least dimensional changes were prepared and adhered to 24 acrylic resin disks using tray adhesive. Same immersion procedure was followed as in group I. The data were analyzed by one way ANOVA and Tukey s multiple tests. Results: Of four impression materials used, PVS (heavy body) was the most dimensionally stable, and Polyether was the least dimensionally stable in both the groups. Interpretation and Conclusion: Within the limitation of the study, PVS (heavy body) was most stable, and polyether was least stable of all the impression materials. Key Words: Acrylic resin trays, dimensionally stable, disinfectants, immersion, impression materials Address for correspondence: Dr. Poonam K. Khinnavar, Department of Prosthodontics Including Crown and Bridge and Implantology, Bapuji Dental College and Hospital, Davangere, Karnataka, India. E mail: kpoonamk2000@yahoo.com Received: 26 th June, 2014, Accepted: 23 rd March, 2015 INTRODUCTION Dental impression materials are used to register the form and relation of the teeth and the surrounding oral tissues. Quick Response Code: Access this article online Website: www.j-ips.org DOI: 10.4103/0972-4052.155034 Impression materials are subjected to several factors that can result in dimensional change. The accuracy also largely depends on the disinfection procedures. Dental impressions are potential sources for cross contamination and should be disinfected. Among the issues to be resolved are the composition, concentration of the ideal disinfectant, optimal exposure time, and the interaction between impression material and disinfectant solution. [1] The most reliable method of disinfection is immersion of the impression. With this method, the disinfectant solution will come into contact with all surfaces of the impression material The Journal of Indian Prosthodontic Society Apr-Jun 2015 Vol 15 Issue 2 131

and tray. [2] Elastomers may be susceptible to dimensional change if immersed for a long time because few of them are hydrophilic in nature, and few are hydrophobic in nature. Most commonly used disinfectants for dental impressions are glutaraldehyde and sodium hypochlorite. [3] The purpose of this study was to assess the dimensional accuracy of the elastomeric impression materials during cold sterilization in 2% glutaraldehyde and 0.525% sodium hypochlorite. MATERIALS AND METHODS Study was conducted to measure and compare the linear dimensional changes of four representative rubber elastomeric impression materials after their immersion in 2% glutaraldehyde solution and 0.525% sodium hypochlorite solution. Materials Polyether (Impregum Penta Soft, 3M ESPE, Germany)/Medium body Polyvinyl siloxane (PVS) (Imprint TM, II Garant, 3M ESPE, Germany)/Heavy body PVS (Imprint TM, II Garant, 3M ESPE, Germany)/ Regular body Hydrophilic addition reaction silicone (Aquasil Ultra Heavy, DENTSPLY/CAULK, USA)/Medium body 2% glutaraldehyde solution and 0.525% sodium hypochlorite solution Tray adhesive (Vinyl Polysiloxane adhesive and Polyether adhesive 17 ml liquid. 3M ESPE, Germany) Acrylic Resin Tray material (M.P Sai Enterprise, Mumbai 53). Group I study Preparation of mold A study mold was prepared according to revised American Dental Association (ADA) specification no. 19. [4] [Figures 1 and 2]. Selection and manipulation of materials The material was loaded into a fine tipped impression syringe and applied to lined areas of the die. A polyethylene sheet followed by a flat glass plate (of weight 67 g) was placed on top of the mold. After the manipulation of all the impression materials, the die was transferred to thermostatically controlled water bath at a temperature of 32 C ± 2 C (to simulate oral conditions) according to ADA specification No. 19. The disinfectants used 25% glutaraldehyde was converted into 2% glutaraldehyde by diluting it with distilled water 4% sodium hypochlorite was converted into 0.525% sodium hypochlorite by adding buffers and adjusting the ph ranging 7 10. Collection of specimens The entire assembly was removed from the water bath after 13 min. The separated impression was numbered with a marker. Measurement of scribed lines of impression material surface Line reproduction on the specimen was evaluated following the criterion given by ADA specification No. 19. Each horizontal line was evaluated under stereomicroscope at 10 magnification. The line reproduction was considered acceptable if two or three of the horizontal lines were reproduced continuously and well defined. Thus prepared specimens were measuring 30 mm in diameter, 3 mm in thickness and had the lines X, Y, Z, CD, and C D on it. Selection and immersion of specimens in the disinfectants Twenty four samples of each impression material were used, eight were immersed in 2% glutaraldehyde, eight in 0.525% sodium hypochlorite solution, and another eight were allowed to dry bench cure [Figure 3 and Graphs 1,2,3]. After 16 h, specimens were measured under stereomicroscope at 10 magnification. Comparison of linear dimensions of the impression material with those of the master die and the control group The distance between the lines, CD and C D reproduced on the Figure 1: Schematic diagram showing ruled surface of die Figure 2: Specimens of four impression materials used in the study 132 The Journal of Indian Prosthodontic Society Apr-Jun 2015 Vol 15 Issue 2

samples, was measured at three different points PP, QQ, and RR using Leica 3MZ microscope with 10 magnification. Three readings were obtained for each sample, and the overall mean was tabulated and subjected to statistical analysis for the comparison. Statistical analysis The data were analyzed by one way ANOVA analyses. Significant differences were separated by Tukey s multiple comparison test [Table 1]. table also shows the dimensional changes in the specimens in percentage for 2% glutaraldehyde group and 0.525% sodium hypochlorite group. Test for significance showed nonsignificant values for PVS regular body and medium body with P > 0.05. Values are significant for PVS (heavy body) with 0.525% sodium hypochlorite making significant pair with both control group and 2% glutaraldehyde group with P < 0.05. Highly significant values were shown for polyether (medium body). The best impression material with the least dimensional changes was chosen for group II study. Group II study Preparation of acrylic resin disks A total of 24 acrylic resin disks measuring 6 mm thick, 30 mm in diameter were prepared, and bench cured for 14 days, before use. Selection and preparation of best impression material Twenty four samples of the best impression material were prepared. Each of them was cemented to the acrylic resin disc using respective tray adhesive [Figure 4 and Graph 4]. 8, out of 24 samples, were immersed in 2% glutaraldehyde, eight in 0.525% sodium hypochlorite and rest eight were allowed to bench cure. Same measuring procedures were utilized as done in group I. Statistical analysis The data were analyzed using the same tests as group I. RESULTS Group I Table 1 shows the intragroup comparison of four elastomeric impression materials for the Control group, 2% glutaraldehyde group, and 0.525% sodium hypochlorite group, using one way ANOVA test as well as Tukey s multiple range test. This Table 2 shows statistical values comparing different consistencies of PVS impression material. In group I study; PVS (heavy body) was very accurate with respect to Control group, 2% Glutaraldehyde group and 0.525% Sodium Hypochlorite group. Group II Of four impressions; PVS (heavy body) with least dimensional changes was used for Group II study. It shows the mean values and F values of PVS (heavy body) specimens with acrylic resin tray, for each group showing the same results as in group I study for PVS (heavy body) without tray [Table 3]. DISCUSSION Dental professionals are exposed to a wide variety of pathogenic microorganisms in blood and saliva. Because of increasing frequency of acquired immune deficiency syndrome, disinfection and sterilization procedures are of importance. Immersion is the most recommended method. [5] Material Polysulphides Silicones Polyethers Alginates Method of disinfection Use immersion method Use immersion method Spray or use short disinfection time Use spray and leave the impression in bag for recommended disinfection time Figure 3: Samples of four groups kept in two disinfectants and control group each Figure 4: Adhesion of specimen to the acrylic resin disk The Journal of Indian Prosthodontic Society Apr-Jun 2015 Vol 15 Issue 2 133

The procedure of disinfection differs depending on the type of impression material used and also on the chemical agent used. [6] The following methods could be utilized; However, when PVS (regular body) control group was compared with the Control groups of other impression materials, it has shown highly significant values. Evaluation of the accuracy of elastomers after immersion (polyether, vinyl polysiloxane and polysulfide) for 10 min in Neutral Glutaraldehyde, increased the distance between preparations and for polyether it is decreased 15 30 μm with disinfection which was acceptable. [7] Some disinfectant impression combinations proposed changes in the surface texture of the stone, so ideal disinfectant should be determined for each impression material. [8] Most commonly used disinfectants for dental impressions are Glutaraldehyde and Sodium Hypochlorite. They are easily available and can be diluted easily to the recommended percentages. For elastomers especially PVS, when immersed in glutaraldehyde has shown no significant changes. But, acid potentiated glutaraldehyde showed improved quality of surface of dies for the same. Group I study Among the impression materials, if taken individually, PVS (regular body) when compared with the control group have shown no significant difference with P > 0.05 [Table 2]. Sixteen hour immersion in 2% Glutaraldehyde and 1% sodium hypochlorite disinfectants could be used for PVS without any dimensional changes in case of patients with positive reaction for hepatitis B surface antigen. [9] 30 min immersion of PVS in Glutaraldehyde solution, had no negative effects. [10] But the immersion for 60 min showed significant dimensional changes. Although dimensional changes were <0.03%, immersion in Glutaraldehyde solution, caused expansion of the impression material. [11] In the present study, the dimensional changes were up to 0.43% [Table 2]. However, it has been shown that there is a significant difference in dimensional (P 0.05) accuracy among 24 h 1 week and 2 weeks measurement times related to both disinfected and nondisinfected vinyl polysiloxane impressions exhibiting continuing shrinkage over time. [12] According to Johnson, dimensional stability for addition silicone was unsatisfactory. [12] But studies have shown that various disinfectants and immersion periods for PVS have shown good compatibility and are dimensionally stable up to 18 h of the immersion period. [13,14] In the present study, the second impression material, PVS (medium body) has shown no significant difference. For 0.525% Sodium Hypochlorite disinfectant, there is a significant difference in the disinfected and nondisinfected specimen and 0.18% of dimensional change was seen after immersion for 16 h. However, in contrast to above mentioned statement, it is [15] observed that elastomeric impressions in higher concentration Table 1: GROUP I STUDY. Intragroup comparison of four elastomeric impression materials for the Control group, 2% glutaraldehyde group, and 0.525% sodium hypochlorite group Groups Mean values Percentage Percentage Control 2% 0.525% sodium change in 2% change in glutaraldehyde hypochlorite glutaraldehyde 0.525% sodium hypochlorite 1 2 3 F* Significance Significant pairs** Polyvinyl siloxane (regular body) 24.70 24.62 24.59 0.43 0.33 0.67 P>0.05, NS Polyvinyl siloxane (medium body) 24.58 24.53 24.61 0.13 0.18 0.86 P>0.05, NS Polyvinyl siloxane (heavy body) 24.77 24.77 24.69 0.30 0.00 6.12 P<0.05, S 1 and 3, 2 and 3 Polyether (medium body) 24.75 23.08 23.02 6.99 6.74 125.84 P<0.001, HS 1 and 2, 1 and 3 One way ANOVA test, **Tukey s multiple range test. S: Significant, NS: Not significant, HS: Highly significant Table 2: GROUP I STUDY Comparison of different consistencies of polyvinyl siloxane impression material Groups Polyvinyl siloxane regular body Polyvinyl siloxane medium body Polyvinyl siloxane heavy body 1 2 3 F* Significance Significant pairs** Control 24.70 24.58 24.77 6.01 P<0.05, S 2 and 3 2% glutaraldehyde 24.62 24.53 24.77 3.80 P<0.05, S 2 and 3 0.525% sodium hypochlorite 24.59 24.61 24.69 2.40 P>0.05, NS S: Significant, NS: Not significant 134 The Journal of Indian Prosthodontic Society Apr-Jun 2015 Vol 15 Issue 2

up to 5.25% sodium hypochlorite for 30 min caused expansion of impressions. Polyvinyl siloxane (medium body) Glutaraldehyde group and Sodium Hypochlorite group was compared with the same groups of other impression materials. It was highly significant only with Polyether (PE) (medium body). The fourth impression material that is polyether (medium body) showed the highest significant differences among the groups. There was a very significant difference between the nondisinfected specimens and disinfected specimens. This could be attributed to the hydrophilicity of polyethers. [7,17] The third impression material in the present study, PVS (heavy body) specimens when compared with Control group have shown no change in the dimensions. Thus, silicones were insensitive to immersion in Glutaraldehyde. [11,16] In the present study, when intragroup comparison was done for different consistencies of PVS (regular, medium, heavy) with each other, heavy consistency showed minimum dimensional changes with and without disinfection. This property of high dimensional stability of the heavy body could be attributed to higher filler content of the material. [17] Table 3: GROUP-II STUDY Polyvinyl siloxane (heavy body) Mean F* Significance Significant pairs** Polyvinyl siloxane (heavy body) Control 24.77 6.10 P<0.05, S 1 and 3, 2% glutaraldehyde 24.77 2 and 3 0.525% sodium hypochlorite 24.69 *One way ANOVA test, **Tukey s multiple range test. S: Significant PE (medium body) when disinfected by either 10 min immersion or 1 h immersion in 0.5% sodium hypochlorite solution, exhibited expansion with all disinfection time intervals, [12] which was in correlation with the present study. All the solutions produced dimensional changes in polyether even after 15 min immersion and are not recommended for disinfection. [18] They are hydrophilic and can imbibe water and swell when immersed in disinfectant. [7] Hence, the results of the present study show that PVS (Heavy body) was the most stable impression material and have claimed superior in accuracy and stability over polyethers. [19] So when sterilization is imperative as in the case of HIV/ hepatitis, the best option is to use PVS. This was also observed by Johansen and Stackhouse [20] that only addition reaction silicone remained stable after immersion in Glutaraldehyde Graph 2: Comparison between impression materials for 2% Glutaraldehyde group Graph 1: Comparison between impression materials for control group Graph 3: Comparison between impression materials for 0.525% Sodium Hypochlorite group Graph 4: Comparison between Control group, 2% Glutaraldehyde group, 0.525% Sodium Hypochlorite group for polyvinyl siloxane (heavy body) impression material along with acrylic resin tray The Journal of Indian Prosthodontic Society Apr-Jun 2015 Vol 15 Issue 2 135

solution after 16 h. So in the present study PVS (Heavy body) was chosen for the group II study. Group II study No significant difference was seen in the dimensional stability of the specimens adhered to trays (group II), when compared to the specimens not adhered to trays as in group I study. This shows that the acrylic tray material did not make any difference after disinfection. In general, impression materials showed least significant changes for 2% Glutaraldehyde group when compared to 0.525% sodium hypochlorite group. Whereas 0.525% sodium hypochlorite has shown to adversely affect the stability of all the impression materials and show highly significant differences among the nondisinfected and disinfected specimens, especially for PE (medium body). One more observation of the present study was the polyether specimens immersed in 0.525% sodium hypochlorite were lighter in color and sticky compared to the Control group. The reason could be, as it is a bleaching agent in nature. [21] Polyether impression materials with 10 min and 1 h sodium hypochlorite immersion group, when compared with no disinfectant group showed a mottled and sticky surface, [12] which was also observed in the present study. In the present study, PVS (heavy body) was found to be the most dimensionally stable and PE (medium body) was found to be the least dimensionally stable impression material. When intragroup comparison was done between different consistencies of PVS (regular, medium, and heavy consistency), PVS (heavy body) was most stable followed by PVS (medium body) and PVS (regular body). This study suggests a possible method of disinfection for protecting a person, either a dentist or a technician who handle dental impressions and to choose a material of choice. The trays did not affect the dimensional stability of PVS (heavy body). The limitation of this in vitro study was that all the measurements were linear, and the line criterion on the specimens was evaluated to check the dimensional stability. CONCLUSION Within the limitations of the study, following conclusion can be drawn from the present study after 16 h of immersion disinfection. Both the disinfectants affect the dimensional stability of PVS and polyether impression material, after 16 h of immersion disinfection 2% Glutaraldehyde is a better disinfectant when compared to 0.525% Sodium Hypochlorite PVS of different consistencies (regular, medium, heavy) used in this study, PVS (heavy body) is the most stable followed by PVS medium body and regular body Dimensional changes shown by PVS are statistically nonsignificant making it a material of choice The dimensional changes shown by the polyether are statistically significant which makes the material unfit for immersion disinfection There is no difference in the dimensional changes of impressions when it is disinfected along with the acrylic custom tray for PVS (heavy body). REFERENCES 1. McCabe JF, Storer R. Elastomeric impression materials. The measurement of some properties relevant to clinical practice. Br Dent J 1980;149:73 9. 2. Berg JC, Johnson GH, Lepe X, Adán Plaza S. Temperature effects on the rheological properties of current polyether and polysiloxane impression materials during setting. J Prosthet Dent 2003;90:150 61. 3. World Health Organisation. Technical Report Series 512, Viral Hepatitis. New York: WHO; 1973. 4. Revised American Dental Association Specification no 19 for Non aqueous, Elastomeric Dental Impression Materials. J Am Dent Assoc 1977;94:733 41. 5. Infection control recommendations for the dental office and the dental laboratory. ADA Council on Scientific Affairs and ADA Council on Dental Practice. J Am Dent Assoc 1996;127:672 80. 6. Infection control recommendations for the dental office and the dental laboratory. Council on Dental Materials, Instruments, and Equipment. Council on Dental Practice. Council on Dental Therapeutics. J Am Dent Assoc 1988;116:241 8. 7. Adabo GL, Zanarotti E, Fonseca RG, Cruz CA. Effect of disinfectant agents on dimensional stability of elastomeric impression materials. J Prosthet Dent 1999;81:621 4. 8. Storer R, McCabe JF. An investigation of methods available for sterilising impressions. Br Dent J 1981;151:217 9. 9. Herrera SP, Merchant VA. Dimensional stability of dental impressions after immersion disinfection. J Am Dent Assoc 1986;113:419 22. 10. Lepe X, Johnson GH. Accuracy of polyether and addition silicone after long term immersion disinfection. J Prosthet Dent 1997;78:245 9. 11. Bergman B. Disinfection of prosthodontic impression materials: A literature review. Int J Prosthodont 1989;2:537 42. 12. Thouati A, Deveaux E, Iost A, Behin P. Dimensional stability of seven elastomeric impression materials immersed in disinfectants. J Prosthet Dent 1996;76:8 14. 13. Minagi S, Kohada A, Akagawa Y, Tsuru H. Prevention of acquired immunodeficiency syndrome and hepatitis B. Part III: Disinfection of hydrophilic silicone rubber impression materials. J Prosthet Dent 1990;64:463 5. 14. Minagi S, Yano N, Yoshida K, Tsuru H. Prevention of acquired immunodeficiency syndrome and hepatitis B. II: Disinfection method for hydrophilic impression materials. J Prosthet Dent 1987;58:462 5. 15. Anusavice KJ. Phillips Science of Dental Materials. 11 th ed. St. Louis, Missouri: Saunders, An imprint of Elsevier; 2003. 16. Johnson GH, Drennon DG, Powell GL. Accuracy of elastomeric impressions disinfected by immersion. J Am Dent Assoc 1988;116:525 30. 136 The Journal of Indian Prosthodontic Society Apr-Jun 2015 Vol 15 Issue 2

17. Walker MP, Rondeau M, Petrie C, Tasca A, Williams K. Surface quality and long term dimensional stability of current elastomeric impression materials after disinfection. J Prosthodont 2007;16:343 51. 18. Langenwalter EM, Aquilino SA, Turner KA. The dimensional stability of elastomeric impression materials following disinfection. J Prosthet Dent 1990;63:270 6. 19. Lacy AM, Fukui H, Bellman T, Jendresen MD. Time dependent accuracy of elastomer impression materials. Part II: Polyether, polysulfides, and polyvinylsiloxane. J Prosthet Dent 1981;45:329 33. 20. Johansen RE, Stackhouse JA Jr. Dimensional changes of elastomers during cold sterilization. J Prosthet Dent 1987;57:233 6. 21. Available from: http://www.en.wikipedia.org/wiki/sodium.hypochlorite. How to cite this article: Khinnavar PK, Dhanya Kumar BH, Nandeeshwar DB. An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization. J Indian Prosthodont Soc 2015;15:131-7. Source of Support: Nil, Conflict of Interest: None. Staying in touch with the journal 1) Table of Contents (TOC) email alert Receive an email alert containing the TOC when a new complete issue of the journal is made available online. To register for TOC alerts go to www.j-ips.org/signup.asp. 2) RSS feeds Really Simple Syndication (RSS) helps you to get alerts on new publication right on your desktop without going to the journal s website. You need a software (e.g. RSSReader, Feed Demon, FeedReader, My Yahoo!, NewsGator and NewzCrawler) to get advantage of this tool. RSS feeds can also be read through FireFox or Microsoft Outlook 2007. Once any of these small (and mostly free) software is installed, add www.j-ips.org/rssfeed.asp as one of the feeds. The Journal of Indian Prosthodontic Society Apr-Jun 2015 Vol 15 Issue 2 137