Standard Motorized Linear-motion stage Testing method (X axis, Y axis) Standard Motorized stage and 2-phase stepper motor/driver Cross-reference table

Similar documents
Use of Image processing software in Hip Joint surgery

Motorized Precision Goniometer

Nuclear Associates

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Installation of force transducers

Chapter 20: Test Administration and Interpretation

CORESTA RECOMMENDED METHOD N 22

10/23/2018. Ishik University / Sulaimani. Architecture Department. Surveying ARCH 224 CHAPTER -3- Level and Leveling LEVEL AND LEVELING

Shoulder Rehab Program

Parallel-Axis Gear Terminology

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS

914. Application of accelerometry in the research of human body balance

A new geometric and mechanical verification device for medical LINACs

6. Gear Measurement And Testing

Methods of optical measurement for directional light/led-sources and luminaires.

DEFORMATION TRANSDUCER CALIBRATOR OPERATION

Gyroscope. The gyroscope apparatus could easily malfunction or produce incorrect results. It should be treated with extra care.

What is Kinesiology? Basic Biomechanics. Mechanics

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

10 Years Experience in Industrial Phased Array Testing of Rolled Bars

Goniometer series 400

Illustrative exercises for the lectures

Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation

Cybex Leg Extension. Legs

Lecture 2. In The Name of Allah. Instrumentation. Dr. Ali Karimpour Associate Professor Ferdowsi University of Mashhad

REMEMBER GOOD POSTURE DURING ALL YOUR EXERCISES, AVOID SLOUCHING AS YOUR CURRENT PROGRAM BECOMES EASY SLOWLY INCREASE:

First Technology Safety Systems. Design Freeze Status. Flex-PLI-GTR Development

My First Half-Century in the Iron Game

Instruction Manual No A. Goniometer PS-2138, PS-2137

Lecture 2. Statics & Dynamics of Rigid Bodies: Human body 30 August 2018

WHITE PAPER. Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation

What is a stepper motor?

E200 ORT - Optical Rotary Torque Transducer. Contents

FreeMotion 7.7 R Bike

Supplementary Figure 1. Psychology Experiment Building Language (PEBL) screen-shots

India s largest Fitness Equipments Showroom

EXCAVATOR LEARNING PROGRAM. Detailed learning program for the excavator, on multi-machines platforms. Non-binding documents

LUSI XPP Sample Goniometer Engineering Specification DRAFT

Conservative Massive Rotator Cuff Tear Protocol

Transfer of Motor Learning across Arm Configurations

Descriptions of NDT Projects Fall 2004 October 31, 2004

Solar Illumination Study

TEPZZ 85_Z 4A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION

LUSI XPP Detector-Mover Engineering Specification

Conservative Posterior Capsular Instability Protocol

Goniometer WT-85. Goniometer WT-100. Goniometer WT-90. Goniometer WT-120. // West //

Chapter 3 CORRELATION AND REGRESSION

Lecture 2 BME 599: Modeling & Simulation of Movement

LECTURE 13. Dr. Teresa D. Golden University of North Texas Department of Chemistry

DEVICE FOR MUSCLE COORDINATION IMPROVEMENT

Reliability and validity of the GymAware optical encoder to measure displacement data

Overview. Acceptance criteria for all protocols

Analysis of EMG and Biomechanical Features of Sports Aerobics Movements

V New HGP 20. Standard grippers 7.5. Economical and versatile. Self centring. Choice of gripping action. Standard grippers.

Preoperative Planning. The primary objectives of preoperative planning are to:

Reverse Bankart/Posterior Capsulorrhaphy Repair Protocol

MUE247 Alignment Methods and Application H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Axis. B.G. Petty, Basic Electrocardiography, DOI / _2, Springer Science+Business Media New York 2016

Articulators. 5- Wax up and refining the occlusion for dental restorations.

Symposium on Occlusal Articulation. Mandibular Movement Recordings and Articulator Adjustments Simplified. Harry C. Lundeen, D.D.S.

ASSESSMENT OF FLEXIBILITY

THIS IS UNFPA. Male Latex Condom Testing Guidance UNICEF UNFPA WHO Joint Meeting September David Hill

AMS 200. Goniophotometer for small to medium-sized lamps and modules

B E H I N D E V E R Y

Custom-Made Products / Scientific Research Instruments

Stretching. Knees: Rotate your knees in a circle, keeping them together and bending down slightly.

...vibration isolation. Mounts

NC DOUBLE OPPOSING HEAD DRILL

Z5mlc (Locator *) Implants

Orthotics Measurement Board for Tibial Torsion and Toe-Out

FIT TO THE BONE. Lace up your sneakers and build your bones with these workout tips from celebrity fitness trainer Kathy Smith.

European Veterinary Dental College

Custom Motion Systems

High Grade Universal Testing Machines

Paper Airplanes & Scientific Methods

KILLER #8. Workout Summary REALITY FITNESS THE WORKOUTS KILLER #8 1. Don t forget to warm up and cool down! Take a 1 minute break in between each set.

Cervical Solutions. Optio-C Anterior Cervical Plate. with Allograft/Autograft. Surgical Technique Guide

The Golf Swing Speed Challenge (103) - First 3 Weeks

Where Is the Natural Internal-External Rotation Axis of the Tibia?

Biomechanical Analysis of the Deadlift (aka Spinal Mechanics for Lifters) Tony Leyland

We bring quality to light. LGS 350 Goniophotometer

Conservative Multi-Directional Capsular Instability Protocol

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects

Silverstone Interbody System Surgical Technique

Program Chordal Height and Tooth Thickness

Angular Measurements with BIOPAC Goniometers & Torsiometers

Custom Motion Systems

Analysis of 3D Foot Shape Features in Elderly with Hallux Valgus Using Multi-Dimensional Scaling Method

(12) Patent Application Publication (10) Pub. No.: US 2003/ A1. Giannelli (43) Pub. Date: Sep. 4, 2003

SINCE 1978 MADE IN THE USA PRO 7000 SERIES SUPPLEMENTARY MACHINES MEDICAL SERIES. engineered for success

8.SP.1 Hand span and height

Overview. Acceptance criteria for all protocols

American Council on Exercise

EWOO Picasso Trio Scanning Protocol

For more information, and to purchase the complete book on Warrior Fitness, please see

Evaluating the accuracy of markerless body tracking for digital ergonomic assessment using consumer electronics

ADVANCE ULTRASONIC INSPECTION

Electromyogram-Assisted Upper Limb Rehabilitation Device

UNIT 1CP LAB 1 - Spaghetti Bridge

TRANSFORMER ALL IN ONE ISOKINETIC MACHINE ANKLE ELBOW HIP SHOULDER WRIST TRUNK

Transcription:

Standard Motorized stage and 2-phase stepper motor/driver Cross-reference table Standard Motorized Linear-motion stage Testing method (X axis, Y axis) Standard Motorized stage and 2-phase stepper motor/driver Cross-reference table Recommended Recommended Recommended Motor type / Shaft type 5-phase stepper motor/double shaft Motor manufacturer TAMAGAWA Motor model TS36667N13E7 TS36667N11E3 Rated current 0.75A 1.4A Size 42X47 42X33 Step angle N/A N/A N/A 0.72 Excitation maximum static torque 0.24 N-m 0.13 N-m Rotor inertia (Kg*m²) 0.068 10-4 0.035 10-4 Driver Manufacture (optional) Driver model (optional) Motor type / Shaft type 2-phase stepper motor/double shaft Motor manufacturer TAMAGAWA SANYO TAMAGAWA Motor model TS3641N11E2 TS3641N12E3 SH3537-12U10 TS3617N13E8 TS3617N11E1 Rated current 1.5A 1.4A 1.2A 0.95A Size 28X33 28X47.5 35X37 42X47 42X33 Step angle 1.8 Excitation maximum static torque 0.05 N-m 0.09 N-m 0.15N-m 0.32 N-m 0.16 N-m Rotor inertia (Kg*m²) 0.008 10-4 0.018 10-4 0.025 10-4 0.068 10-4 0.035 10-4 Driver Manufacture (optional) Driver model (optional) Motor type / Shaft type Motor manufacturer Motor model Rated current Size Stepping angle Excitation maximum static torque Rotor inertia (Kg*m²) Driver Manufacture (optional) Driver model (optional) 2-phase stepper motor/double shaft SANYO SANYO SANYO SANYO SH2281-5231 SH2285-5231 103H5210-0410 103H5205-0410 1A 1.2A 28X32 28X51.5 42X48 42X34 1.8 N/A 1.8 0.07 N-m 0.01 10-4 0.145 N-m 0.022 10-4 0.37 N-m 0.2 N-m 0.074 10-4 0.035 10-4 2-phase stepper motor of Japanese brand is alternative specification suggested for standard grade motorized stage optional reference only. The most preferred driver is recommended to be specified by as considerations. For different needs, please choose the suitable driver based on real functional needs. The motorized stage performance might not meet specified on the catalogue. interferometer Reference mirror Detection mirror Testing equipment: laser interferometer, Zeiss coordinate measuring machine. In testing, fix the stage bottom board and move the stage workbench. Within predetermined testing range, from the starting position, move and position in a specific direction and measure the difference between actual value and target value. Use the maximum difference as positioning precision. Use laser interferometer or Zeiss coordinate measuring machine (CMM) to repeat measurement for seven times. With half of the obtained maximum error from the error based on one direction to any point stop, measure in the middle point of movement distance and in the directions of two ends and obtain the maximum difference as the repeatability positioning precision. Standard Motorized Linear-motion stage Testing method (X axis, Y axis) E4 Within predetermined testing range, from the origin, make movement positioning for any point from positive direction command, measure actual movement value; make negative direction command (same pulse number) for movement positioning and measure actual movement value; make positive direction (same pulse number) command for movement positioning and measure actual movement value. Make positive direction and negation direction movement seven times and measure the individual actual movement values. The average will be the missed step. E5 162 163

Standard Motorized Linear-motion stage Testing method (X axis, Y axis) Standard Motorized Linear-motion stage Testing method (X axis, Y axis) Standard Motorized Linear-motion stage Testing method (X axis, Y axis) Put the stage on granite workbench. Use micrometer or Zeiss coordinate measuring machine (CMM) for measurement. At the middle of stage work area, use the measured maximum difference as the parallelism. Standard testing gauge block In testing, fix the stage bottom board and move the stage workbench. Within predetermined testing range, from the starting position of stage, move in a specific direction and use standard gauge block as basis to measure the difference between actual value and target value for horizontal straightness and vertical straightness. Use the maximum difference a Dynamic straightness. Standard Motorized Linear-motion stage Testing method (X axis, Y axis) In testing, fix stage and move stage workbench. E6 E7 Put the stage on granite workbench. Set micrometer on the workbench and measure on granite. The measured maximum difference is the Dynamic parallelism. 164 165

Standard Motorized Linear-motion stage Testing method (Z axis) Standard Motorized Linear-motion stage Testing method (Z axis) Standard Motorized Linear-motion stage Testing method (Z axis) interferometer Reference mirror Detection mirror Testing equipment: laser interferometer, Zeiss coordinate measuring machine. In testing, fix the stage bottom board and move the stage workbench. Within predetermined testing range, from the starting position, move and position in a specific direction and measure the difference between actual value and target value. Use the maximum difference as positioning precision. Put the stage on granite workbench. Use micrometer or Zeiss coordinate measuring machine (CMM) for measurement. At the middle of stage work area, use the measured maximum difference as the parallelism. Standard Motorized Linear-motion stage Testing method (Z axis) Use laser interferometer or Zeiss coordinate measuring machine (CMM) to repeat measurement for seven times. With half of the obtained maximum error from the error based on one direction to any point stop, measure in the middle point of movement distance and in the directions of two ends and obtain the maximum difference as the repeated positioning precision. E8 Within predetermined testing range, from the origin, make movement positioning for any point from positive direction command, measure actual movement value; make negative direction command (same pulse number) for movement positioning and measure actual movement value; make positive direction (same pulse number) command for movement positioning and measure actual movement value. Make positive direction and negation direction movement seven times and measure the individual actual movement values. The average will be the missed step. In testing, fix the stage bottom board and move the stage workbench. Within predetermined testing range, from a stage starting position, move in a specific direction and measure the difference between actual value and target value. Use the maximum difference as Dynamic parallelism. E9 166 167

Standard Motorized Linear-motion stage Testing method (Z axis) Standard Motorized Goniometer stage Standard Motorized Linear-motion stage Testing method (Z axis) In testing, fix stage and move stage workbench. Put the stage on granite workbench. Set micrometer on the workbench and measure on the standard gauge block. The measured maximum difference is the Dynamic vertical. Goniometer stage image detection Testing equipment: image detection system, Zeiss coordinate measuring machine. In testing, fix the stage bottom board and move the stage workbench. Within predetermined testing range, from the starting position, move and position in a specific direction and measure the difference between actual value and target value. Use the maximum difference as positioning precision. Standard Motorized Goniometer stage Testing method ( axis) According to baseline, set testing standard angle for movement. In clockwise (counterclockwise) direction, fix the angle for positioning and repeat seven measurements. In the same direction, use the half of the maximum difference from any stop point as Repeatability positioning precision value. Select clockwise rotation for angle positioning and set the position x1. Continue counterclockwise rotation for angle positioning and set the position E10 y1. Set arbitrary position for seven measurements. Measure in the middle of movement distance and in the direction of two ends. The obtained maximum is the missed step. E11 Missed step calculation: (x1+x2+x3 +x7) (y1+y2+y3 +y7) max 7 7 168 169

Standard Motorized Goniometer stage Standard Motorized Standard Motorized Goniometer stage Testing method ( axis) Height of rotation center Rotation center difference within specified range Standard circle for testing Rotation range Testing equipment: altimeter, Zeiss coordinate measuring machine. Within predetermined testing range, from a starting position, move in a specific direction and measure and check if the distance from bench to circle center falls within target value, which is the height of rotation center. image detection Testing equipment: image detection system. In testing, fix the stage bottom board and move the stage workbench. According to baseline, set standard angle position for movement plane and fix and position rotation angle in clockwise (counterclockwise) direction. Measure the difference between actual value and target value in 360 rotation. The obtained maximum is the positioning precision. Standard Motorized Testing method ( axis) E12 Rotation range Testing equipment: altimeter, Zeiss coordinate measuring machine. In testing, fix the stage bottom board and move the stage workbench. Use any angle in clockwise (counterclockwise) direction as standard, measure deviation for stop angle for seven times. With half of the obtained maximum error, in the middle of movement distance and the direction of two ends, obtain the maximum value as the Repeatability positioning precision. Select clockwise rotation for angle positioning and set the position x1. Continue counterclockwise rotation for angle positioning and set the position y1. Set arbitrary position for seven measurements. Measure in the middle of movement distance and in the direction of two ends. The obtained maximum is the missed step. E13 Missed step calculation: Within predetermined testing range, from a starting position, move in a specific direction and measure and check if the actual circle center falls within target value, which is the rotation center deflection precision. max (x1+x2+x3 +x7) (y1+y2+y3 +y7) 7 7 170 171

Standard Motorized Standard Motorized Standard Motorized Testing method ( axis) Put the stage on granite workbench. Use micrometer or Zeiss coordinate measuring machine for measurement. At the middle of stage work area, use the measured maximum difference as the parallelism. In testing, fix the stage bottom board and move the stage workbench. Within predetermined testing range, from a starting position in the circumference, move in a specific direction and measure the maximum difference between actual value and target value as Dynamic concentricity. Standard Motorized Testing method ( axis) In testing, fix stage and move stage workbench. E14 E15 Put the stage on granite workbench. Use micrometer on the stage workbench or Zeiss coordinate measuring machine for measurement. As the stage workbench makes one rotation, use the maximum measurement difference as the Dynamic parallelism. 172 173