EUROANESTHESIA 2007 Munich, Germany, 9-12 June 2007

Similar documents
LMA Supreme Second Seal. Maintain the airway. Manage gastric contents. Meet NAP4 recommendations.

A randomised comparison between Cobra PLA and classic laryngeal mask airway and laryngeal tube during mechanical ventilation for general anaesthesia

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic Cholecystectomy A Clinical Comparative Study

ISPUB.COM. M Roberts, M Mani, A Wilkes, E Flavell, N Goodwin INTRODUCTION

Other methods for maintaining the airway (not definitive airway as still unprotected):

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

Use of the Intubating Laryngeal Mask Airway

Supra-glottic Airway Devices

Recent Advances in Airway Management HA Convention 2014

A Comparative Study of Classic LMA and Proseal LMA in Paralyzed Anaesthetized Patients

Citation British journal of anaesthesia, 104. pp ; 2010 is available onlin

University of Groningen

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

Deposited on: 11 February 2010

AIRWAY MANAGEMENT AND VENTILATION

Original Contributions

LEVITAN S FIBREOPTIC STYLET: BEYOND BARRIERS. - Our Perspective.

Randomised comparison of the LMA Supreme with the I-Gel in spontaneously breathing anaesthetised adult patients

Clinical Study Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults

Anatomy and Physiology. The airways can be divided in to parts namely: The upper airway. The lower airway.

International Journal of Health Sciences and Research ISSN:

Dr. Ranjeet Rana De 1, Dr. Saurav Shekhar 2, Dr. D G Pathak 3, Dr. Harshwardhan 4, Dr. Shashank Dhiraj 5 1,2,4,5

LMA for Laparoscopic Surgery

Introducing the Fastrach-LMA. Prepared by Jim Medeiros, NREMT-P Regional Field Coordinator Lord Fairfax EMS Council

ISPUB.COM. The Video-Intubating Laryngoscope. M Weiss THE LARYNGOSCOPE INTRODUCTION TECHNICAL DESCRIPTION

Tracheostomy and laryngectomy airway emergencies: an overview for medical and nursing staff

Evaluation of Baska Mask Performance in Laparoscopic Cholecystectomy

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

A Comparative Study of Two Disposable Supraglottic Devices in Diagnostic Laparoscopy in Gynecology

ISSN X (Print) Research Article. *Corresponding author Dr. Souvik Saha

Buyers guide. Laryngeal masks CEP 08010

COMPARATIVE CLINICAL EVALUATION OF PROSEAL LMA WITH I - GEL AIRWAY IN PATIENTS UNDERGOING ELECTIVE SURGICAL PROCEDURES UNDER GENERAL ANAESTHESIA

Comparison of Three Disposable Extraglottic Airway Devices in Spontaneously Breathing Adults

Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway

Tibe ProSeal Laryngeal Mask Airway

Cricoid pressure: useful or dangerous?

Asai and Shingu Table 1 Size selection and recommended cuff volumes Size Patients Body size Recommended cuff volumes (ml) Connector colour 0 Newborn <

We will not be using the King LTS-D in our system!

Difficult Airway. Victor M. Gomez, M.D. Pulmonary Critical Care Medicine Medical City Dallas Hospital

Comparison of clinical performance of i-gel with laryngeal mask airway pro-seal in elective surgery in adults

Airway Management Essentials Self-Study Guide

ASPIRATION DURING ANAESTHESIA

Cricoid pressure impedes placement of the laryngeal mask airway

LMA Unique Airway Portfolio

ISPUB.COM. The Use of LMA in Newborn Resuscitation. R Vadhera INTRODUCTION VENTILATION

Basic Scope Care and Handling

INDEPENDENT LUNG VENTILATION

Comparative evaluation of Ambu AuraGain with ProSeal laryngeal mask airway in patients undergoing laparoscopic cholecystectomy

A Clinical Comparative Study Of Evaluation Of Proseal LMA V/S I-GEL For Ease Of Insertion And Hemodynamic Stability; A Study Of 60 Cases

Comparison of I-gel with Baska Mask Airway for Controlled Ventilation in Obese Patients Undergoing Ambulatory Surgery: A Prospective Randomized Trial

I-gel vs cuffed tracheal tube during volume controlled ventilation in elective laparoscopic cholecystectomy

Comparison of efficacy of the Laryngeal tube with the Laryngeal mask airway in securing the upper airway

Gastroesophageal regurgitation during anesthesia and controlled ventilation with six airway devices

Comparison of the Baska â mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery

Cuffed Tracheal Tubes in Children - Myths and Facts. PD Dr. Markus Weiss Department of Anaesthesia University Children s Hospital Zurich Switzerland

Materials and Methods

Controversial issues in ambulatory anesthesia

Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy

Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff*

Nicolette Mosinski MPAS, PA-C

Nitrous oxide diffusion into the cuffs of disposable laryngeal mask airways

A CRITICALLY ILL CHILD PRESENTING AT AN ACUTE TRUST- A CLINICAL AND ETHICAL CHALLENGE

Received 1 November 2009 Revised 8 December 2009 Accepted 10 December 2009

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

MD (Anaesthesiology) Title (Plan of Thesis) (Session )

Deposited on: 24 February 2009

Anesthetic challenges when elective case becomes emergent

Cuffed or uncuffed ETT in pediatric anesthesia? Dr. Renata Haghedooren Dr. Sophie Chullikal Dr. Julie Lauweryns

British Journal of Anaesthesia 82 (5): (1999)

Mao-Kai Chen 1, Hung-Te Hsu 1, I-Cheng Lu 2, Chih-Kai Shih 3, Ya-Chun Shen 1, Kuang-Yi Tseng 1 and Kuang-I Cheng 1,4*

Review Article. Summary. Introduction. D. K. Baidya, 1 Chandralekha, 2 V. Darlong, 3 R. Pandey, 3 S. Maitra 4 and P. Khanna 5

Comparison of the LMA Supreme vs the i-gel TM in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation*

GENERAL ANAESTHESIA AND FAILED INTUBATION

REVISTA BRASILEIRA DE ANESTESIOLOGIA

RESPIRATION AND THE AIRWAY Comparison of the i-gel with the cuffed tracheal tube during pressure-controlled ventilation

12/15/2010. Presented by: Jim Fox EMT-PS EMS-I EMS Assistant Coordinator Des Moines Fire Department

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 3/ Issue 64/Nov24, 2014 Page 13923

The Glidescope Ò system: a clinical assessment of performance

A new airway device for small laboratory animals

J. Brimacombe, 1 L. Holyoake, 2 C. Keller, 3 J. Barry, 4 D. Mecklem, 4 A. Blinco 5 and K. Weidmann 5

In 2011 I received an unrestricted lecture honorarium from Ambu I have been loaned equipment by Intavent Direct (Teleflex) and Aircraft Medical As an

This interdisciplinary clinical support document provides guidelines for the safe establishment of an artificial airway.

(ix) Difficult & Failed Intubation Queen Charlotte s Hospital

Blind Insertion Airway Devices (BIAD)

Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis

Dr.Bharghavi.M 2 nd year post graduate Dept of Anaesthesia

All bedside percutaneously placed tracheostomies

Pre-Hospital Laryngeal Mask Airway Insertion Program Overview

Jay B. Brodsky, M.D. Professor Department of Anesthesia tel: (650) Stanford University School of Medicine fax: (650)

Airway/Breathing. Chapter 5

Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery

H: Respiratory Care. Saskatchewan Association of Licensed Practical Nurses, Competency Profile for LPNs, 3rd Ed. 79

Basic Airway Management

1 Chapter 40 Advanced Airway Management 2 Advanced Airway Management The advanced airway management techniques discussed in this chapter are to

Airway/Breathing. Chapter 5

Chapter 40 Advanced Airway Management

Case Report Complete Obstruction of Endotracheal Tube in an Infant with a Retropharyngeal and Anterior Mediastinal Abscess

Randomized Comparison of Actual and Ideal Body Weight for Size Selection of the Laryngeal Mask Airway Classic in Overweight Patients

Transcription:

AIRWAY MANAGEMENT AND VENTILATION IN DAY SURGERY EUROANESTHESIA 2007 Munich, Germany, 9-12 June 2007 2RC1 IAN SMITH Senior Lecturer in Anaesthesia University Hospital of North Staffordshire Stoke-on-Trent, Staffordshire, United Kingdom Saturday Jun 9, 2007 13:00-13:45 Room 13b INTRODUCTION The laryngeal mask airway (LMA), introduced in 1988, revolutionised airway management by providing an attractive alternative to tracheal tube or face mask. The LMA rapidly became popular in the elective, fasted day surgery population, where it provided a clear airway while avoiding the trauma, stress response and need for neuromuscular block associated with tracheal intubation. With greater experience of the LMA in simple, spontaneously breathing cases, there has also been an increase in its use for more controversial applications, such as in extended laparoscopies and in the prone position. Some of these more controversial uses will be reviewed. The original reusable LMA has been further developed into a wide variety of variants, including single use, disposable devices, the intubating LMA (ilma) and the ProSeal. The role of some of these developments in day surgery will also be reviewed. In addition, a great many manufacturers now produce their own versions of the laryngeal mask in both reusable and single-use versions. While it is often assumed that these devices will perform similarly to the original LMA, this assumption is rarely supported by data. This review will highlight some areas where performance has been compared. Finally, the success of the LMA has spurred the development of numerous other supraglottic airways. These are often marketed after minimal clinical evaluation with little or no published evidence to support the claims for their performance [1]. While a comprehensive evaluation of all the new airways is beyond the scope of this review, some of the more prominent devices will be discussed and, where possible, compared to the LMA. CONTROVERSIAL USES OF THE LMA SIMPLE LAPAROSCOPY Using the LMA for gynaecological laparoscopy has been controversial in the past, as the risk of aspiration was thought to be increased by the pneumoperitoneum and by head down tilt. It is now recognised that these manoeuvres actually increase the barrier pressure protecting against regurgitation, since both increase lower oesophageal pressure to a greater extent than intragastric pressure. Continuous oesophageal ph monitoring confirms a low incidence of significant gastroesophageal reflux when using the LMA for laparoscopy, and adverse events appear rare in practice. In one evaluation of the LMA for laparoscopy in which 20% of the patients were obese and 14% had reflux, regurgitation was observed in only 1% overall and no patient aspirated [2]. The pneumoperitoneum, absorption of CO2 and adverse patient positioning all compromise ventilation during laparoscopy and statistically significant changes in end-tidal carbon dioxide tension and arterial ph develop if patients are permitted to breath spontaneously. These are small in magnitude, however, and correct rapidly once the intraabdominal gas is released. In practice, spontaneous ventilation through the LMA does not appear to increase adverse events and is probably acceptable during short gynaecological laparoscopic procedures. In this context, short has been suggested to be operating times of 15 minutes or less with less than 15 degrees of table tilt and intraabdominal pressures below 15 mmhg. As longer and increasingly complex laparoscopic surgery is being performed, the adverse mechanics of spontaneous ventilation become unacceptable and the overall safety of the LMA is largely unknown. - 11 -

LAPAROSCOPIC CHOLECYSTECTOMY Laparoscopic cholecystectomy is increasingly being performed as a day case procedure and the use of an airway which is less invasive than tracheal intubation is an attractive prospect. In addition, the procedure generally requires a head-up tilt, which is more mechanically favourable for the LMA compared to pelvic laparoscopy. However, the longer duration of the procedure and greater disturbance of the upper gastrointestinal almost certainly increase the risk of aspiration. Bile reflux is a distinct possibility and may produce especially severe pulmonary damage when aspirated. In addition, bile reflux will increase gastric volume, making regurgitation more likely. Controlled ventilation using either a LMA or tracheal tube resulted in comparable oxygen saturation, expired CO 2, airway pressures and surgical conditions during laparoscopic cholecystectomy and there have been other small series which have confirmed the effectiveness of the LMA for this procedure [3]. However, there is far too little published evidence to establish the safety of the LMA for laparoscopic cholecystectomy and at least one case of aspiration pneumonia has been reported. Many would consider the LMA to be contraindicated for laparoscopic cholecystectomy. The ProSeal LMA (Intavent Orthofix Ltd, Maidenhead, UK) is designed to permit better drainage of gastric contents while affording greater protection against aspiration through a higher seal pressure. This LMA variant would appear to be a better choice for laparoscopic cholecystectomy and, indeed, has been shown to result in better ventilation following the establishment of a pneumoperitoneum than that which could be achieved through a standard LMA [4]. In addition, a gastric drainage tube could be readily placed in all patients, 78% of whom were found to have residual gastric fluid which was bile stained in almost half the cases [4]. This finding tends to support the notion that pulmonary aspiration may be more likely with this procedure. While the ProSeal is probably the more effective form of LMA for laparoscopic cholecystectomy, there is again insufficient evidence to confirm that its safety is comparable to tracheal intubation and it cannot be relied upon to prevent aspiration. THE LMA IN THE PRONE POSITION The use of the LMA in the prone position is still considered controversial. The main concern seems to be that the airway may fall out or become dislodged while the patient is face down with disastrous consequences. No such event appears to have been reported, however, and case reports and a few small series support the simplicity and effectiveness of using the LMA in prone patients. If the patient is adequately supported with sufficient clearance under the abdomen, spontaneous breathing is usually quite effective. A reinforced LMA gives greater protection against kinking of the tube, although a conventional LMA is usually acceptable. It is the author s practice to induce anaesthesia conventionally and then turn the patient prone once the airway is secure. However, others have the patient position themselves in a comfortable face-down position and then induce anaesthesia while prone, turning the head slightly to facilitate LMA insertion [5]. This obviously reduces the amount of manual handling and minimises the risk of patient (or staff) injury. The fact that the LMA can readily be inserted with the patient prone shows that it would be quite possible to replace an airway in the unlikely event that it was dislodged during surgery. Contrast this with the difficulties in trying to reintubate a paralysed prone patient in whom a tracheal tube had become unintentionally displaced. THE LMA FAMILY The main developments of the conventional LMA have been the ProSeal and the intubating LMA. The ProSeal has already been discussed in relation to laparoscopy. Its revised cuff design increases seal pressure, while an integral conduit facilitates gastric drainage. It is probably the LMA of choice for controlled ventilation (although in the author s experience, spontaneous ventilation through a conventional LMA is usually satisfactory), but is more difficult to insert and cannot be relied upon to protect against aspiration [6]. The intubating LMA (ilma) acts as a conduit for tracheal intubation. Minor trauma and cardiovascular stimulation may be reduced, but at the expense of less successful first time intubation and the risk of serious oesophageal injury [7]. One novel use of the ilma is to facilitate vocal cord biopsy during suspension laryngoscopy, the wide diameter of the tube giving adequate access for a flexible bronchoscope, biopsy forceps and laser fibre [8]. ALTERNATIVE AND DISPOSABLE LMAS A large number of manufacturers now produce their variation of the laryngeal mask airway. While these bear a close resemblance to the original LMA, the aperture bars of the latter, intended to prevent obstruction by the epiglottis, are still protected by patent and so are not a feature of the alternative devices. It is still not clear if this difference will affect performance, as detailed comparisons of the numerous devices have rarely been performed. However, it should not be assumed that everything which looks like a LMA will perform like one. - 12 -

Both the original LMA Company and several other manufacturers produce disposable LMAs designed for single use. Unlike the silicone cuff of the reusable models, these are generally made of PVC to reduce costs. One of the more extensively studied is the Portex Soft Seal, which appears to be associated with a higher seal pressure, but also an increased incidence of throat soreness [9]. The LMA Unique, from the manufacturer of the original LMA, appears less traumatic and is easier to insert with better final position [9,10]. One of the main drivers towards disposable LMAs has been the fear of possible transmission of prion diseases. The magnitude of this theoretical risk appears to have reduced greatly with significantly reduced estimates for the worst case incidence of new variant Creutzfeldt-Jakob disease, questioning the need for single-use airways which generally have poorer performance than their reusable counterparts [9]. ALTERNATIVE AIRWAY DEVICES The LMA has been an enormous clinical and commercial success which many inventors and manufacturers have attempted to replicate. This is a tough challenge, since the LMA is easy to use, provides a reliable airway and is relatively atraumatic. Desirable improvements would be a lower incidence of throat soreness and protection against aspiration, although the latter has rarely been a claim for alternative supraglottic airways. The variety of available supraglottic airways is overwhelming. Airways are subject to the regulations which govern medical devices, which are more concerned with manufacturing materials and standards, rather than efficacy [1]. In contrast to new drugs, novel airways can be marketed with little if any published comparative trials to substantiate the claims of their manufacturers. Furthermore, these devices are frequently modified, often without obvious notification, rendering previous comparative data useless. As a consequence, new airways are often launched in a blaze of glory, only to be withdrawn a few years later when problems become evident or unimpressive performance results in poor sales. One example is the cuffed oropharyngeal airway (COPA) which, according to the manufacturer s literature, offered improved airway management in spontaneous ventilation. In practice, it was difficult to choose the correct size of COPA and, compared to a LMA, was more difficult to insert and resulted in a poorer airway [11]. The COPA was finally withdrawn in 2003. THE AIRWAY MANAGEMENT DEVICE The Airway Management Device (AMD) is another example of a device marketed with claims of safe airway maintenance and minimal soft tissue trauma, unsupported by clinical literature. The original design, comprising a silicone tube with two inflatable cuffs, was found to be not very effective in practice and modifications were subsequently made to the cuff design. Despite these modifications, first time successful insertion was still only possible in 70 83% of cases and, more importantly, the airway became obstructed in 19 22% of patients [12,13]. Although some of these cases could be resolved by manipulation of the airway, in many the AMD failed to provide an adequate airway and had to be replaced by an alternative device [12,13]. It is believed that the AMD has subsequently been withdrawn. THE LARYNGEAL TUBE The laryngeal tube consists of an airway tube with a small distal cuff at the tip and a larger, interconnected cuff in the central part; ventilation occurs through an opening between the cuffs. Since its original conception (intended as an emergency form of airway), the device has been modified and is now available in a number of variants, some of which have themselves undergone modification. The two basic designs are the laryngeal tube (LT) with a single lumen and blind distal cuff and the laryngeal tube-suction (LTS), which incorporates a second channel opening beyond the distal cuff to facilitate the placement of a gastric tube. Both devices are currently available as reusable devices, with a silicone cuff, and as single use disposables. Insertion of the LT is generally described as easy and a satisfactory airway can be obtained in most cases [14]. Most comparative studies have evaluated the LT during controlled ventilation. Despite minor differences, leak pressures and ventilatory parameters have been found to be broadly similar to those achieved with either the standard or ProSeal LMAs. There have been far fewer evaluations of the LT during spontaneous ventilation; one early report found it to be quite unsatisfactory, although the device has been modified since then. However, airway obstruction does seem to be a consistent problem with the LT, with a reported incidence ranging from 2 40% and a greater requirement to adjust its position compared to the LMA [14]. Although versions of the LT for use in children are produced, there is only limited evidence from the paediatric population, where the performance seems to be somewhat less satisfactory than in adults. Similarly, evaluation of the LTS is incomplete, with rather variable results being obtained. It is currently not clear how the performance of the disposable LT and LTS compares with that of their reusable counterparts. At present, it would appear that the LT approximately shares the indications and contraindications of the LMA, with similar ease of insertion and comparable degrees of trauma and throat soreness. However, it does not appear to produce as consistently clear an airway and it has not been extensively evaluated in spontaneous ventilation, where the LMA is already well established. Other variants of the LT may yet find a useful role following further evaluation, possibly in the management of the difficult airway, but it is hard to see any clear advantage of the LT over the LMA in routine day surgery. - 13 -

THE STREAMLINED PHARYNX AIRWAY LINER (SLIPA) SLIPA is both an abbreviation of streamlined pharynx airway liner and a descriptive term for this boot (or slipper) shaped device. The SLIPA is a disposable device moulded from soft plastic into a hollow shape which lines the pharynx. Because the SLIPA is specifically shaped to fill the pharynx, it requires no cuff to achieve a seal, although it is necessary to match the size of the device to that of the patient [15]. This necessitates a wide range of sizes, currently there are six intended for adults. The SLIPA was developed by a South African anaesthetist and initially marketed in that country in 2002. It was launched in Europe at the 2004 ESA by Hudson Medical, but an acquisition shortly after that meeting ensured that only established products were marketed and the SLIPA returned to its original distributor. It is currently available in much of Europe, although it does not seem to be very actively promoted. There is still relatively little published experience with the SLIPA and even less which is independent of its inventor. Insertion generally appears to be easy and comparable to the LMA, although a small failure rate has been observed, even in experienced hands [15,16]. In use, the device appears to give a good seal and a reliable airway. There is currently conflicting evidence as to whether the SLIPA is any more traumatic than the LMA and on the comparative incidence of throat soreness. One interesting claim for the SLIPA is that, in the event of regurgitation, there would be less risk of aspiration than with other similar devices. * This is based on the hollow design of the airway, which could theoretically act as a reservoir for regurgitated material, preventing it from reaching the trachea. This claim is supported by a laboratory study, which showed that the SLIPA prevented any simulated aspiration with regurgitated volumes of up to 50 ml [16]. This was comparable to, or slightly better than the ProSeal (depending on the rate of regurgitation) and superior to the LMA. However, these tests were performed on a specially designed pharynx model which had been constructed around the template of a SLIPA airway. There is much less evidence of how the SLIPA would perform in the more variable anatomy of the clinical pharynx, and the airway is still recommended only for fasted patients [16]. At present, there is still too little evidence to fully assess the possible role of the SLIPA. While it may provide somewhat greater protection against aspiration, this has yet to be proven in practice. Any worthwhile protection, as well as optimal performance in controlled ventilation and during low flow anaesthesia, is likely to require a precise fit and it will be quite a challenge to reliably choose the correct size of SLIPA on every occasion. PA XPRESS The PA Xpress comprises an anatomically curved tube with an inflatable cuff in the mid-section, a conical tip with gill-like protrusions and an airway opening between these. Although commercially available, it has undergone limited evaluation which has demonstrated slower and more traumatic insertion, a high incidence of sore throat and an unacceptably high incidence of failures and minor complications [17,18]. COBRA The Cobra is a single-use, silicone tube with an inflatable cuff near to a tip which is flattened into a smooth surface pierced by a parallel series of grilles. Intended for both controlled and spontaneous ventilation, the device is available in the USA and Europe. Evaluation is still rather limited, but insertion is reported to be easy, but with a high incidence of minor trauma and throat soreness in up to 50% [19,20]. Of greater concern is that one study was prematurely halted after two unexpected cases of aspiration with the Cobra which the authors suggest may be related to the design of the airway [20]. SUMMARY Undoubtedly, inventors will continue to produce alternative airway devices and some will be marketed. While these new designs may appear attractive, we should greet them with caution until their efficacy and safety have been properly evaluated. While the LMA is not a perfect airway, few alternatives have yet demonstrated clear advantages (especially in day surgery anaesthesia) and none share its long history. CONFLICT OF INTEREST None - 14 -

REFERENCES 1. Cook TM. Novel airway devices: spoilt for choice? (Editorial). Anaesthesia 2003;58:107 10. 2. Bapat PP, Verghese C. Laryngeal mask airway and the incidence of regurgitation during gynecological laparoscopies. Anesthesia and Analgesia 1997;85:139 43. 3. Maltby JR, Beriault MT, Watson NC, Fick GH. Gastric distension and ventilation during laparoscopic cholecystectomy: LMA-Classic vs. tracheal intubation. Canadian Journal of Anaesthesia 2000;47:622 6. 4. Lu PP, Brimacombe J, Yang C, Shyr M. ProSeal versus the classic laryngeal mask airway for positive pressure ventilation during laparoscopic cholecystectomy. British Journal of Anaesthesia 2002;88:824 7. 5. Ng A, Raitt DG, Smith G. Induction of anesthesia and insertion of a laryngeal mask airway in the prone position for minor surgery. Anesthesia and Analgesia 2002;94:1194 8. 6. Cook TM, Nolan JP, Verghese C, et al. Randomized crossover comparison of the ProSeal with the classic laryngeal mask airway in unparalysed and anaesthetized patients. British Journal of Anaesthesia 2002;88:527 33. 7. Branthwaite MA. An unexpected complication of the intubating laryngeal mask. Anaesthesia 1999;54:166 7. 8. Windfuhr JP, Remmert S. Intubation laryngeal mask: atraumatic diagnostic tool in suspension laryngoscopy. Acta Oto Laryngologica 2005;125(1):100 7. 9. Cook TM, Trumpelmann P, Beringer R, Stedeford J. A randomised comparison of the Portex Softseal laryngeal mask airway with the LMA-Unique during anaesthesia. Anaesthesia 2005;60(12):1218 25. 10. Brimacombe J, von Goedecke A, Keller C, Brimacombe L, Brimacombe M. The laryngeal mask airway Unique versus the Soft Seal laryngeal mask: a randomized, crossover study in paralyzed, anesthetized patients. Anesthesia and Analgesia 2004;99:1560 3. 11. Greenberg RS, Brimacombe J, Berry A, Gouze V, Piantadosi S, Dake EM. A randomized controlled trial comparing the cuffed oropharyngeal airway and the laryngeal mask airway in spontaneously breathing anesthetized adults. Anesthesiology 1998;88:970 7. 12. Sivasankar R, Bahlmann UB, Stacey MR, Sehgal A, Hughes RC, Hall JE. An evaluation of the modified Airway Management Device. Anaesthesia 2003;58:558 61. 13. Pay LL, Lim Y. Comparison of the modified Airway Management Device with the Proseal laryngeal mask airway in patients undergoing gynaecological procedures. European Journal of Anaesthesiology 2006;23:71 5. 14. Asai T, Shingu K. The laryngeal tube (Review). British Journal of Anaesthesia 2005;95:729 36. 15. Miller DM, Lavelle M. A streamlined pharynx airway liner: a pilot study in 22 patients in controlled and spontaneous ventilation. Anesthesia and Analgesia 2002;94:759 61. 16. Miller DM, Light D. Laboratory and clinical comparisons of the streamlined liner of the pharynx airway (SLIPA ) with the laryngeal mask airway. Anaesthesia 2003;58:136 42. 17. Casati A, Vinciguerra F, Spreafico E, Putzu M, Mamo D, Marchetti C. The new PA Xpress airway device during mechanical ventilation in anaesthetized patients: a prospective, randomized comparison with the laryngeal mask airway. European Journal of Anaesthesiology 2004;21(8):667-9. 18. Cook TM, McCormick B, Gupta K, Hersch P, Simpson T. An evaluation of the PA Xpress pharyngeal airway a new single use airway device. Resuscitation 2003;58(2):139 43. 19. Turan A, Kaya G, Koyuncu O, Karamanlioglu B, Pamukcu Z. Comparison of the laryngeal mask (LMA) and laryngeal tube (LT) with the new perilaryngeal airway (CobraPLA) in short surgical procedures. European Journal of Anaesthesiology 2006;23:234 8. 20. Cook TM, Lowe JM. An evaluation of the Cobra Perilaryngeal Airway: study halted after two cases of pulmonary aspiration. Anaesthesia 2005;60:791 6. - 15 -