Randomised comparison of the LMA Supreme with the I-Gel in spontaneously breathing anaesthetised adult patients

Similar documents
Citation British journal of anaesthesia, 104. pp ; 2010 is available onlin

ISPUB.COM. M Roberts, M Mani, A Wilkes, E Flavell, N Goodwin INTRODUCTION

ISSN X (Print) Research Article. *Corresponding author Dr. Souvik Saha

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

Received 1 November 2009 Revised 8 December 2009 Accepted 10 December 2009

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

Use of the Intubating Laryngeal Mask Airway

Other methods for maintaining the airway (not definitive airway as still unprotected):

A randomised comparison between Cobra PLA and classic laryngeal mask airway and laryngeal tube during mechanical ventilation for general anaesthesia

Optimal Size AMBU Laryngeal Mask Airway Among Asian Adult Population

University of Groningen

Deposited on: 11 February 2010

International Journal of Health Sciences and Research ISSN:

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

Comparison of efficacy of the Laryngeal tube with the Laryngeal mask airway in securing the upper airway

Anatomy and Physiology. The airways can be divided in to parts namely: The upper airway. The lower airway.

REVISTA BRASILEIRA DE ANESTESIOLOGIA

LMA Supreme Second Seal. Maintain the airway. Manage gastric contents. Meet NAP4 recommendations.

I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic Cholecystectomy A Clinical Comparative Study

AIRWAY MANAGEMENT AND VENTILATION

RESPIRATION AND THE AIRWAY. Editor s key points. L. Theiler 1,2 *, M. Kleine-Brueggeney 1,3, N. Urwyler 1,4,T.Graf 1, C. Luyet 1 and R.

Comparison of the Baska â mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery

Comparison of Three Disposable Extraglottic Airway Devices in Spontaneously Breathing Adults

A Comparative Study of Classic LMA and Proseal LMA in Paralyzed Anaesthetized Patients

COMPARATIVE CLINICAL EVALUATION OF PROSEAL LMA WITH I - GEL AIRWAY IN PATIENTS UNDERGOING ELECTIVE SURGICAL PROCEDURES UNDER GENERAL ANAESTHESIA

A Comparative Study of Two Disposable Supraglottic Devices in Diagnostic Laparoscopy in Gynecology

Nicolette Mosinski MPAS, PA-C

Recent Advances in Airway Management HA Convention 2014

the in spontaneously breathing anaesthetised adult

British Journal of Anaesthesia 82 (5): (1999)

Clinical Study Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults

Comparison of Ease of Insertion and Hemodynamic Response to Lma with Propofol and Thiopentone.

Introducing the Fastrach-LMA. Prepared by Jim Medeiros, NREMT-P Regional Field Coordinator Lord Fairfax EMS Council

Dr. Ranjeet Rana De 1, Dr. Saurav Shekhar 2, Dr. D G Pathak 3, Dr. Harshwardhan 4, Dr. Shashank Dhiraj 5 1,2,4,5

Pharyngolaryngeal Morbidity with the Laryngeal Mask Airway in Spontaneously Breathing Patients

Comparison of I-gel with Baska Mask Airway for Controlled Ventilation in Obese Patients Undergoing Ambulatory Surgery: A Prospective Randomized Trial

Blind Insertion Airway Devices (BIAD)

A Comparative Study of Supreme LMA Vs I-gel: Two Supraglottic Airway Devices in Short Surgical Procedures

Comparison of the LMA Supreme vs the i-gel TM in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation*

A prospective randomized study comparing the efficacy of the LMA Classic TM, the

AIRWAY MANAGEMENT SUZANNE BROWN, CRNA

Comparison of clinical performance of i-gel with laryngeal mask airway pro-seal in elective surgery in adults

Tibe ProSeal Laryngeal Mask Airway

Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery

ORIGINAL ARTICLE. Shashank Chitmulwar, MD, Charulata Deshpande, MD, DA ABSTRACT. ANAESTHESIA, PAIN & INTENSIVE CARE

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

Airway Management and The Difficult Airway

Evaluation of Baska Mask Performance in Laparoscopic Cholecystectomy

Angkana Lurngnateetape,, MD. Department of Anesthesiology Siriraj Hospital

i-gel TM supraglottic airway in clinical practice: a prospective observational multicentre study

J. Brimacombe, 1 L. Holyoake, 2 C. Keller, 3 J. Barry, 4 D. Mecklem, 4 A. Blinco 5 and K. Weidmann 5

Advanced Airway Management. University of Colorado Medical School Rural Track

CONTINUING EDUCATION IN HONOR OF NORMAN TRIEGER, DMD, MD

student handbook BARS handbook September 2012.indd Front Cover 27/11/12 12:08 PM

Airway Management. DFMRT Casualty Care Examination Course. Revision notes for. January Les Gordon

Airway/Breathing. Chapter 5

Materials and Methods

Randomized Comparison of Actual and Ideal Body Weight for Size Selection of the Laryngeal Mask Airway Classic in Overweight Patients

Airway/Breathing. Chapter 5

12/15/2010. Presented by: Jim Fox EMT-PS EMS-I EMS Assistant Coordinator Des Moines Fire Department

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

We will not be using the King LTS-D in our system!

Waitin In The Wings. Esophageal/Tracheal Double Lumen Airway (Combitube ) Indications and Use for the Pre-Hospital Provider

Similar oropharyngeal leak pressures during anaesthesia with i-gel TM, LMA-ProSeal TM and LMA-Supreme TM Laryngeal Masks

2007 Recertification Session. Airway review

This interdisciplinary clinical support document provides guidelines for the safe establishment of an artificial airway.

Original Contributions

Ingo Bergmann *, Thomas Allen Crozier, Markus Roessler, Hanna Schotola, Ashham Mansur, Benedikt Büttner, José Maria Hinz and Martin Bauer

Omiros Chalkeidis*, Georgios Kotsovolis, Apostolos Kalakonas, Maria Filippidou, Christos Triantafyllou, Dimitris Vaikos, Epaminondas Koutsioumpas

Comparison of the i-gel and the LMA-Unique laryngeal mask airway in patients with mild to moderate obesity during elective short-term surgery

Success of Tracheal Intubation with Intubating Laryngeal Mask Airways

Airway Management. Key points. Rapid Sequence Intubation. Rapid Sequence Intubation Recognizing difficult airway Managing difficult airway

Airway Management & Safety Concerns Experience from Bariatric Surgery

Veena Mathur, Deepak Garg, Neena Jain, Vivek Singhal, Arvind Khare, Surendra K. Sethi*

Cricoid pressure: useful or dangerous?

Dr.Bharghavi.M 2 nd year post graduate Dept of Anaesthesia

Comparison of the air-q ILA and the LMA-Fastrach in airway management during general anaesthesia

Basic Airway Management

Clinical Study McGrath Video Laryngoscope May Take a Longer Intubation Time Than Macintosh Laryngoscope

EUROANESTHESIA 2007 Munich, Germany, 9-12 June 2007

Editor s key points. M. Kleine-Brueggeney 1,2, L. Theiler 1,3 *, N. Urwyler 1,4, A. Vogt 1 and R. Greif 1

LMA CTrach TM in patients with anticipated difficult airway: A retrospective study

Positive pressure ventilation with the laryngeal mask airway in non-paralysed patients: comparison of sevoflurane and propofol maintenance techniques

Comparative Study of laryngeal mask airway Supreme and laryngeal mask airway Classic in paralyzed patients

Original Research Article. Amol P. Singam 1, Arpita A. Jaiswal 2 *, Ashok R. Chaudhari 1

Comparison of the Hemodynamic Responses with. with LMA vs Endotracheal Intubation

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 3/ Issue 64/Nov24, 2014 Page 13923

promed Surgical Gowns Sterile Oropharyngeal Airway Guedels Solution

Airway Workshop Lecture. University of Ottawa

Airway Management. Teeradej Kuptanon, MD

Complications following the use of the Combitube, tracheal tube and laryngeal mask airway

MD (Anaesthesiology) Title (Plan of Thesis) (Session )

General Medical Procedure. Emergency Airway Techniques (General Airway Protocol)

I-gel vs cuffed tracheal tube during volume controlled ventilation in elective laparoscopic cholecystectomy

Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope. Suzuki, Akihiro ; Katsumi, Norifumi ; Honda, Takashi ; Sasakawa,

Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis

Asai and Shingu Table 1 Size selection and recommended cuff volumes Size Patients Body size Recommended cuff volumes (ml) Connector colour 0 Newborn <

If you suspect airway problems, get a second opinion before you anaesthetise, not after!

The Laryngeal Tube. An Evaluation of the Laryngeal Tube During General Anesthesia Using Mechanical Ventilation

Comparative evaluation of Ambu AuraGain with ProSeal laryngeal mask airway in patients undergoing laparoscopic cholecystectomy

Transcription:

Anaesth Intensive Care 2010; 38: Randomised comparison of the LMA Supreme with the I-Gel in spontaneously breathing anaesthetised adult patients E. F. F. CHEW*, N. HANEEM, C. Y. WANG Department of Anaesthesia, Faculty of Medicine, University Malaya, Lembah Pantai, Kuala Lumpur, Malaysia SUMMARY We compared the performance of the LMA Supreme (SLMA) with the I-Gel (i-gel) during anaesthesia in spontaneously breathing adult patients. Ninety patients with American Society of Anesthesiologists physical status I or II were studied in a prospective randomised controlled study. Our primary outcome measure was oropharyngeal leak pressure. We also compared the overall insertion success rate, ease of insertion, adequacy of ventilation and incidence of complications. The mean (SD) oropharyngeal leak pressure for the SLMA was 25.6 (5.1) cmh 2 O, which was greater than for the i-gel 20.7 (5.9) cmh 2 O (P=0.0001). The first attempt and overall insertion success rates were similar between the two groups (SLMA 97.8 and 97.8%; i-gel 93.3 and 100%, P=0.132). The SLMA was rated easier to insert than the i-gel (P=0.011), but the time taken for insertion (P=0.433) was similar. The incidence of complications was low in both groups. The grade of fibreoptic view was better with the i-gel than the SLMA (P=0.001). We conclude that in adults with normal airways, the SLMA is easier to insert and provides a higher oropharyngeal leak pressure. but fibreoptic views are better with the i-gel. Key Words: laryngeal mask airway, LMA Supreme, insertion, fibreoptic, oropharyngeal leak pressure Since the introduction of the LMA Classic laryngeal mask airway (Intravent Orthofix, Maidenhead, UK) in 1983 1 it has gained widespread popularity 2. The LMA Supreme (SLMA) and the I-Gel (i-gel) are two newly developed disposable supraglottic airway devices. The claimed potential advantages of both devices include easier insertion, more effective ventilation, better airway protection, minimal tissue compression and stability following insertion 3-5. The SLMA is a single use LMA with a built-in gastric drain tube, elliptical airway tube for easy placement and prevention of kinking, an integral bite-block, a large pre-curved cuff for effective airway seal, moulded fins in the cuff to protect the airway from epiglottic folding and a reinforced tip and moulded distal cuff to prevent folding at the tip. The i-gel is also a single-use supraglottic device with built-in gastric drain tube. It consists of an anatomical firm tube section and an anatomical * M.B., B.S., Medical Officer. M.B., B.S.; M.Anaes., Lecturer. M.B., Ch.B., F.R.C.A., Professor. Address for correspondence: Professor C. Y. Wang, Department of Anaesthesia, Faculty of Medicine, University Malaya, Lembah Pantai, 50603 Kuala Lumpur, Malaysia. Email: wangcy@um.edu.my Accepted for publication on June 24, 2010. non-inflatable cuff section. Along the tubing is an integral bite-block, an elliptical buccal cavity stabiliser that eliminates rotation and provides vertical strength to aid insertion, and a V-shaped connector to the cuff to prevent kinking. It has an anatomical non-inflatable silicon cuff that seals the laryngeal inlet and prevents neurovascular compression at the larynx. An epiglottic rest at the cuff prevents downfolding of the epiglottis and laryngeal inlet obstruction. We were interested in these two devices due to their claimed advantages, and the rise in the routine use of disposable supraglottic airway adjuncts for maintenance of anaesthesia in our institution. Therefore we designed a study to compare the performance of the SLMA and i-gel during anaesthesia in spontaneously breathing adult patients. Our primary outcome was oropharyngeal leak pressure (OLP). Secondary outcomes included number of insertion attempts, ease of insertion, passage of a gastric tube, manipulations required, ventilation quality and fibreoptically determined laryngeal view grade. METHODS With approval from the University Malaya Medical Centre Ethical Committee and informed written consent, we studied 90 patients (American Society of

2 E. F. F. Chew, N. Haneem, C. Y. Wang Anesthesiologists physical status I or II), aged 16 to 55 years, undergoing elective surgery not requiring tracheal intubation. Exclusion criteria included patients who were at risk of regurgitation of gastric contents or if they had pathology of the neck, upper respiratory or upper alimentary tracts, previous or anticipated airway problems or body mass index >35 kg.m -2. All patients were fasted overnight. Intravenous access was obtained and all patients received standard monitoring before induction of anaesthesia. Patients heads were supported on a firm silicone headrest and were kept in a neutral position. After preoxygenation for three minutes, anaesthesia was induced with fentanyl 2.0 µg.kg -1 and propofol 2 mg.kg -1. Induction of anaesthesia was confirmed by loss of verbal contact with the patient, loss of eyelash reflex and relaxation of the jaw. If coughing, gagging or body movement occurred during insertion, a further dose of propofol 0.5 mg.kg -1 was given to achieve an adequate depth of anaesthesia. Anaesthesia was maintained with sevoflurane 2 to 3% in oxygen. Intermittent fentanyl boluses were given for additional analgesia. After induction, patients were randomly allocated to one of the two groups using sequentially allocated numbered, sealed opaque envelopes containing the name of one of the two devices. A single anaesthetist (with experience in using the LMA Classic on more than 500 patients), who had used the SLMA and i-gel devices 20 times, inserted the devices. Both devices were inserted according to the manufacturer s instructions including weight-based recommendations for the size (SLMA: size 3 for patients 30 to 50 kg, size 4 for patients 50 to 70 kg, size 5 >70 kg; i-gel: size 3 for patients 30 to 60 kg, size 4 for patients 50 to 90 kg, size 5 for patients >90 kg). The standard pre-use tests were performed. Both devices were lubricated using a water-based lubricant on the tip and posterior surface as recommended by the manufacturers, and the SLMA was fully deflated prior to insertion. After insertion, the SLMA device was then inflated to a pressure of 60 cmh 2 O using a handheld pressure gauge device (VBM, Medizintechnik, Sulz, Germany). After insertion of the airway, the breathing system was connected to the device. An initial assessment of airway patency and the ability to ventilate the lungs was made by gently squeezing the reservoir bag, while observing the presence of end-tidal carbon dioxide waveforms and chest movement. If it was not possible to ventilate the lungs, the following airway manoeuvres were allowed: chin-lift, jawthrust, head extension or flexion on the neck. After any manoeuvre, adequacy of ventilation was reassessed. If it was not possible to insert the device or ventilate through it, one more attempt at insertion was allowed. A failed attempt was defined as removal of the device from the mouth. If placement failed after two attempts, the patient was withdrawn from the study and insertion was recorded as a failure. The time to insertion, defined as the time from picking up the device to obtaining the first end-tidal carbon dioxide trace, was measured by an independent observer. The ease of insertion was graded as 1=easy, 2=moderate, 3=difficult or 4=impossible. The number of insertion attempts was recorded. Once ventilation was successful, as confirmed by CO 2 waveform and chest movement, the OLP of each device was measured, i.e. the minimum airway pressure at which gas audibly leaks around the airway using a fresh gas flow of 3 l.minute -1 with the adjustable pressure-limiting valve completely closed. The peak airway pressure is not allowed to exceed 40 cmh 2 O. Following this, the device s anatomic positioning was evaluated by fibreoptic endoscopy using the following scoring system 6 : 1=vocal cords entirely visible; 2=vocal cords or arytenoids cartilages partially visible; 3=epiglottis only visible; 4=no laryngeal structures visible. During maintenance of anaesthesia, if there was airway obstruction, adjusting the position of the device or the patient s head and neck or removal and reinsertion of the device were allowed. The number of manipulations of each device during insertion and maintenance of anesthesia were recorded. At the end of the operation the device was removed after the patient regained consciousness and opened his or her mouth to command. The presence or absence of blood on the device, injury to the teeth or lips and the incidence of perioperative complications (i.e. coughing, gagging, hiccup, vomiting, regurgitation, aspiration, laryngospasm and bronchospasm, hypoxia [peripheral oxygen saturation, oxygen saturation measured by pulse oximetry <95%]) were noted. Patients were asked one hour postoperatively by a blinded investigator whether they had a sore throat (yes or no). The sample size for the OLP (primary outcome) was based on a pilot study of 16 patients. The mean airway pressure at which gas leaked around the i-gel was 20 cmh 2 O (SD 8 cmh 2 O). Power analysis determined that a study of 31 patients in each group had 80% power to detect a difference in airway seal pressure of 5 cmh 2 O. For secondary outcomes, we used the reported incidence of overall attempt successful insertions of SLMA in non-paralysed

LMA Supreme with the I-Gel in adult patients 3 anaesthetised patients of 95 to100% 7,8, and a minimum clinically important difference of 20% between i-gel and SLMA, based on using a two-tailed alpha value (0.05) and a beta value (0.2). Under these conditions, a sample size of 45 patients per group was estimated to be sufficient to detect a difference in success rate of 20%., We therefore studied 90 patients. The data for OLP were normally distributed and Student s t-test was used for analysis. Insertion times were not normally distributed and the Mann- Whitney U-test was used. The grade of fibreoptic view and number of manipulations were compared by Mann-Whitney U-test. Complications and efficacy of ventilation between the groups were compared by Fisher s exact test. Commercial SPSS 15.0 software for Windows (SPSS Inc., Chicago, IL, USA) was used for data processing. Data are presented as mean and standard deviations, range, interquartile range and percentage. P <0.05 was considered statistically significant. RESULTS Forty-five patients in each group were studied. Patients characteristics are presented in Table 1. In one patient, the SLMA was inserted easily but ventilation was unsuccessful and there was no expiratory carbon dioxide waveform despite two attempts; an LMA Classic was then inserted with easy ventilation. During insertion, two patients in the SLMA had complications related to laryngospasm despite easy insertion. These patients data were excluded from further analysis during maintenance of anaesthesia. As a result, SLMA was used for maintenance in 42 cases and the i-gel for 45 cases. The first-time success rates at achieving an effective airway were 44 of 45 (97.8%) for the SLMA and 42/45 (93.3%) for the i-gel. Two attempts were Table 1 Characteristics of patients (n=90) undergoing anaesthesia with the SLMA or i-gel, and size of device used. Values are mean (SD) or number (proportion). SLMA (n=45) Gender, M/F 15/30 12/33 i-gel (n=45) Age, y 35 (15) 42 (116) Weight, kg 61 (13) 60 (12) Height, cm 161 (8) 160 (8) BMI, kg.m -2 23 (4) 23 (5) Mallampati Score, 1/2/3/4 36/8/1/0 35/9/1/0 Size, 3/4/5 18/18/9 23/22/0 SLMA=LMA Supreme, i-gel=i-gel, M=male, F=female, BMI=body mass index. required in 2/45 (4.4%) for the i-gel. There was one failure to establish a patent airway with the SLMA and none with the i-gel. The ease of insertion was rated easier in SLMA compared to i-gel (P=0.011). However, the time taken for insertion was similar for the two groups (P=0.433). The OLP was higher for the SLMA than for the i-gel (P=0.0001). Once the airway was established, complications during anaesthesia were infrequent for both devices. In one patient in the SLMA group, the airway became partially obstructed soon after the surgery started (one manipulation required to maintain a patent airway). There were no complications requiring removal. One patient in the SLMA group developed mild laryngospasm and another patient had hiccups soon after surgery started, which were self-limiting after the administration of additional fentanyl. There were no arterial desaturations in either groups. Both devices were tolerated well during emergence from anaesthesia. The incidence of trauma, gastric tube passing at the first attempt and perioperative complications were similar between groups. Grade of fibreoptic view was better for i-gel than the SLMA (Table 2, P=0.001). Table 2 Comparison of the SLMA and i-gel. Ease of insertion, measurements and complications related to insertion of the SLMA and i-gel in 90 patients (for the SLMA, n=42 for all except number of attempts and ease of insertion). Values are number (proportion), median (IQR [range]) or mean (SD). Insertion SLMA (n=45) i-gel (n=45) P value Attempts, 1/2/failed 44/0/1 42/3/0 0.132 Ease of insertion, easy/moderate/ difficult/impossible Time for insertion, s 34/10/1/0 23/22/0/0 0.011 20.0 (15.0-25.0 [15.0-30.0]) Manipulations 0 0 20.0 (15.0-25.0 [12.0-30.0]) 0.433 Laryngospasm 2 (4.5%) 0 (0%) 0.242 Maintenance SLMA (n=42) i-gel (n=45) P value Oropharyngeal leak pressure cmh 2 O 25.6 (5.1) 20.7 (5.9) 0.0001 Manipulations 1 (2.4%) 0 0.483 Laryngospasm/hiccup 2 (4.4%) 0 (0%) 0.230 Fibreoptic score, 1/2/3/4 26/6/7/3 41/3/0/1 0.001 Mucosal injury 3 (7.1%) 4 (8.9 %) 1.0 Sore throat 4 (9.5%) 2 (4.4%) 0.4230 1=vocal cords entirely visible, 2=vocal cords or arytenoids cartilages partially visible, 3=epiglottis only visible, 4=no laryngeal structures visible. SLMA=LMA Supreme, i-gel=i-gel, IQR=interquartile range.

4 E. F. F. Chew, N. Haneem, C. Y. Wang DISCUSSION We found that the SLMA OLP was higher than i-gel and this was both statistically significant and clinically relevant. As a result, the SLMA may be more useful than the i-gel for controlled ventilation. Our results differ from the findings of Theiler et al who found that the OLP was similar between the SLMA and i-gel 8. The difference in our results might relate to the different group of patients 9. We did not perform any power calculations for the secondary outcome measures, so the remainder of our findings must be considered exploratory. We found that the SLMA was slightly easier to insert compared to i-gel (P=0.011) but the clinical relevance of the difference is not known. Moreover, time to achieve an effective airway was similar between the two devices. The first attempt and overall insertion success rates were similar between groups. This concords with other studies that have shown a high success rate with both devices 7,8,10. There was one complete failure to establish a patent airway with the SLMA despite easy insertion. No complete failures occurred in the i-gel group. Insertion complications on the other two patients with the SLMA were related to laryngospasm. During maintenance of anaesthesia the airway was clear throughout the operation for most cases, except for one patient in the SLMA group who needed one manipulation to maintain the airway. There were two intraoperative complications in the SLMA group and none in the i-gel. One patient developed mild laryngospasm and the other patient had hiccups. No conclusions can be drawn about the incidence of these complications due to the small numbers involved. There was minimal blood-staining with both the devices. This is similar to previous reports 7,8,10. Postoperative sore throat was also similar between devices. Fibreoptic view was better with the i-gel device. This suggests that the device might be better suited to use as a conduit in difficult airway management and failed intubation, but larger studies would be required to confirm this finding. However, in this study we found no association between the fibreoptic position and the functioning of these devices. This is similar to other studies 11,12. Gastric tube insertion via the drain tube was successful at the first attempt in all patients. This is also very similar to the success rates reported in other studies 7,8,10. Our study has a number of limitations. First, our study was conducted in non-paralysed patients, hence our findings may be less applicable to paralysed patients. However, there is indirect evidence from mucosal pressure studies that pharyngeal muscle tone is similar in paralysed and non-paralysed patients 13. Second, both devices were inserted by a single experienced user. Therefore, our results may not be applicable to inexperienced users. Further studies are needed to assess ease of insertion and first time insertion success rate by novice users, as supraglottic airways are incorporated in the difficult airway management protocol 2. Third, the intraoperative data were collected by an unblinded observer, introducing a potential source of bias. We conclude that both devices are suitable for routine use during maintenance of anaesthesia in spontaneously breathing patients with normal airways, as both SLMA and i-gel appear to be effective in establishing a clinically patent airway and have high success rates of insertion and low morbidity. The SLMA provides a higher OLP. Our findings suggest also that the SLMA might be slightly easier to insert than the i-gel, and that the fibreoptic views may be better with the i-gel. ACKNOWLEDGEMENT The SLMAs used in this study were provided by Aerotrach Sdn Bhd, Malaysia and the i-gels by Med Supplies (M) Sdn Bhd, Malaysia free of charge. REFERENCES 1. Brain AIJ. The laryngeal mask: a new concept in airway management. Br J Anaesth 1983; 55:801-805. 2. Americian Society of Anaesthesiologists Task Force on management of the difficult airway. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anaesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2003; 98:1269-1277. 3. Cook T, Gatward JJ, Handel J, Hardy R, Thompson C, Srivastava R et al. Evaluation of the LMA Supreme in 100 non-paralysed patients. Anaesthesia 2009; 64:555-562. 4. Gatward JJ, Cook TM, Seller C, Handel J, Simpson T, Vanek V et al. Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients. Anaesthesia 2008; 63:1124-1130. 5. Timmermann A, Cremer S, Eich C, Kazmaier S, Bräuer A, Graf BM et al. Prospective clinical and fiberoptic evaluation of the Supreme laryngeal mask airway. Anesthesiology 2009; 110:262-265. 6. Verghese C, Berlet J, Kapila A, Pollard R. Clinical assessment of the single use laryngeal mask airway the LMA-Unique. Br J Anaesth 1998; 80:677-679. 7. Verghese C, Ramaswamy B. LMA-Supreme a new singleuse LMA with gastric access: a report on its clinical efficacy. Br J Anaesth 2008; 101:405-410. 8. Theiler LG, Kleine-Brueggeney M, Kaiser D, Urwyler N, Luyet C, Vogt A et al. Crossover comparison of the laryngeal mask supreme and the i-gel in simulated difficult airway scenario in anesthetized patients. Anesthesiology 2009; 111:55-62. 9. Asai T, Muroa K, Yukawa H, Shingu K. Reevaluation of appropriate size of the laryngeal mask airway. Br J Anaesth 1999;

LMA Supreme with the I-Gel in adult patients 5 83:478-479. 10. Janakiraman C, Chethan DB, Wilkes AR, Stacey MR, Goodwin N. A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway. Anaesthesia 2009; 64:674-678. 11. Francksen H, Bein B, Cavus E, Renner J, Scholz J, Steinfath M et al. Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures. Eur J Anaesthesiol 2007; 24:134-140. 12. Brimacombe J. Anatomy. In: Laryngeal mask anesthesia. Principles and practice, 2nd ed. London: WB Saunders Compnay 2005. p. 73-104. 13. Keller C, Brimacombe J. Influence of neuromuscular block, mode of ventilation and respiratory cycle on pharyngeal mucosal pressures with the laryngeal mask airway. Br J Anaesth 1999; 83:480-482.