Patient and Linac QA - present and the future

Similar documents
IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

Online Care, Online Control, Online Confidence

Quality assurance in external radiotherapy

iba-dosimetry.com INTEGRATED QUALITY ASSURANCE Solution Overview

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

1ª Jornada de Análisis de Riesgos en RT. 10 de Dic 2014 José Luis Roldán

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

SunCHECK Patient Comprehensive Patient QA

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Limits of Precision and Accuracy of Radiation Delivery Systems

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

EORTC Member Facility Questionnaire

Dosisverifikation mit Delta 4 Discover während der Behandlung

Level of Accuracy Practically Achievable in Radiation Therapy. David Followill and RPC staff August 6, 2013

Eric E. Klein, Ph.D. Chair of TG-142

QA for Clinical Dosimetry with Emphasis on Clinical Trials

QUALITY ASSURANCE IN RADIOTHERAPY THERAPY EQUIPMENT

Unrivaled, End-to-End

Efficient Dosimetry for Proton Therapy

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

In-Room Radiographic Imaging for Localization

iviewdose Confidence and assurance in dose delivery

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

In-Room Radiographic Imaging for Localization

PGY-1. Resident Review Session Schedule

MEDICAL PHYSICS INTERNATIONAL Journal, vol.3, No.2, 2015 HOW TO

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Effective and efficient radiotherapy dosimetry audit: Where to next?

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams

What Can Go Wrong in Radiation Treatment: Data from the RPC. Geoffrey S. Ibbott, Ph.D. and RPC Staff

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms

SRS Uncertainty: Linac and CyberKnife Uncertainties

The RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Leila E. A. Nichol Royal Surrey County Hospital

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Computed tomography Acceptance testing and dose measurements

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

The Journey of Cyberknife Commissioning

Collapsed Cone Convolution 2D illustration

Small field diode dosimetry

The Radixact System Experience at Miami Cancer Institute. Tino Romaguera, D.Sc. Senior Physicist

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

Patient QA Recommended Publications

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Image Guided Proton Therapy and Treatment Adaptation

Quality Assurance of Helical Tomotherapy Machines

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

ph fax

brochure DISO fronte.jpg Locandina commerciale

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Overview of Advanced Techniques in Radiation Therapy

IMRT QA: Point Dose Measurements or 2D Array?

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Pre-treatment verification for IMRT / IGRT and Rotational therapy

Independent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

Evaluating Pre-Treatment IMRT & VMAT QA Techniques Using Receiver Operating. Characteristic (ROC) Analysis. Allison Lorraine Mitchell

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

Who Should Know Radiation Oncology Coding?

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

Current NCS Subcommittees

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

IMRT point dose measurements with a diamond detector

Realtime dose monitoring technologies: Luxury or Necessity

Verification of Advanced Radiotherapy Techniques

Blue Phantom 2 with. Built for the next generation. Introduction Introduction Introduction Introtro Intro Intro

Importance of Radiation Dosimetry standards in preclinical radiobiology studies

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

GAMMA DOSE DISTRIBUTION EVALUATION OF XiO TREATMENT PLANNING SYSTEM FOR STATIC FIELD IMRT, USING AAPM TG-119

Transcription:

Patient and Linac QA - present and the future IBA Dosimetry Sandra Kos Service Department Customer Support Specialist sandra.kos@iba-group.com 1

IBA Dosimetry Part of IBA Group OUR MISSION At IBA we dare to develop innovative solutions pushing back the limits of science. We share ideas and know-how with our customers, our partners and leading experts to bring new solutions for the diagnosis and treatment of cancer and for the benefits of patients. We care of the well-being of patients and stakeholders as it is together that we complete our mission to Protect Enhance and Save lives. 1998/1999 IBA enters the field of Dosimetry Proton Therapy Radio Pharma Solutions Located in Schwarzenbruck, Germany Dosimetry Industrial and Sterilisation Solutions 2

Quality assurance in radiotherapy Quality assurance in radiotherapy ALL procedures that ensure consistency of the medical prescription, and safe fulfilment of that prescription, as regards the dose to the target volume, together with minimal dose to normal tissue, minimal exposure of personnel and adequate patient monitoring aimed at determining the end result of the treatment. CT CBCT TPS. Epid Symmetry 3

Linac QA The parameters to be tested and the tests to be performed The specific equipment to be used to perform the tests The geometry of the tests The frequency of the tests The staff group or individual performing the tests, as well as the individual supervising and responsible for the standards of the tests and for actions that may be necessary if problems are identified The expected results The tolerance and action levels The actions required when the tolerance levels are exceeded 4

Linac QA Different protocols available on market: DIN TG -142 Elekta Varian Siemens IEC-60976.. 5

Linac QA All-in-One All Connected All Secure myqa is a unique platform that connects QA applications, people, and know-how through a Central Database and the Cloud. It offers full support throughout all of your QA, and enables you access to the different software modules and all of your data from one intuitive interface - anywhere & anytime. 6

7

Pass-Fail Numeric Dosimetry: Energy, Output, Profile, Wedge Constancy CBCT: Contrast, Geometric Distortion, HU Constancy, Spatial resolution, Uniformity and Noise MLC: Leaf position accuracy, Moving Window/Segmental IMRT, Picket fence, VMAT/Dynamic MLC EPID (MV) / Planar (KV): Scaling Test 8

Linac QA Cloud Solution 9

Patient QA Errors in Patient Treatment: - incorrect manual parameter transfer - reversal of images in treatment planning - erroneous calculation for soft wedge - incorrect Intensity Modulated Radiotherapy (IMRT) planning Need for pre-treatment patient plan verification 10

Patient QA Film Dosimetry TPS Phantom Calculations EPID Dosimetry 11

Patient QA myqa Patients 12

Patient QA Compass 2 in 1 Solution Calculation based TPS Check Measurement based 13

Patient and Linac QA - Future 14

Patient and Linac QA - Future Multifunctional detector for your: 1. Pre-treatment QA 2. Online treatment monitoring per fraction 3. Machine and Morning QA in the future** Dolphin is ready anytime for your QA without the typical hardware setup; no cabling required Fluence generated from the detector response for high-resolution Monte Carlo dose modeling 15

16

??? Questions??? 17

Thank you / Hvala Sandra Kos Service Department Customer Support Specialist sandra.kos@iba-group.com /company/iba /ibaworldwide /ibagroup /iba 18