Intensity Modulated RadioTherapy

Similar documents
Advances in external beam radiotherapy

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Technology Challenges of Commercial Medical Electron Accelerators

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Future upcoming technologies and what audit needs to address

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Sarcoma and Radiation Therapy. Gabrielle M Kane MB BCh EdD FRCPC Muir Professorship in Radiation Oncology University of Washington

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

Leila E. A. Nichol Royal Surrey County Hospital

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

EORTC Member Facility Questionnaire

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

IMAT: intensity-modulated arc therapy

Chapters from Clinical Oncology

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

Elekta - a partner and world-leading supplier

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

HALF. Who gets radiotherapy? Who gets radiotherapy? Half of all cancer patients get radiotherapy. By 1899 X rays were being used for cancer therapy

I. Equipments for external beam radiotherapy

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

Radiotherapy. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

A review of RTTQA audit. Karen Venables

First, how does radiation work?

Application(s) of Alanine

Cancer Treatment by Charged Particles - Carbon Ion Radiotherapy -

Quality Assurance of Helical Tomotherapy Machines

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

3D-CRT Breast Cancer Planning

Teaching linear accelerator physics using simulation software. Marco Carlone, BC Cancer Agency Nicole Harnett, Princess Margaret Cancer Centre

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

Small field diode dosimetry

Questions may be submitted anytime during the presentation.

Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Imaging of Radiation Dose Using Cherenkov Light

Neutron dose evaluation in radiotherapy

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

MEDICAL MANAGEMENT POLICY

Brain Tumor Radiosurgery. Gabor Fichtinger, PhD

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Changing Paradigms in Radiotherapy

PGY-1. Resident Review Session Schedule

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

From position verification and correction to adaptive RT Adaptive RT and dose accumulation

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Hampton University Proton Therapy Institute

Use of Electronic Portal Image Detectors for Quality Assurance of Advanced Treatments

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

Independent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA

A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment

The Physics of Oesophageal Cancer Radiotherapy

State-of-the-art proton therapy: The physicist s perspective

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Page 1. Helical (Spiral) Tomotherapy. UW Helical Tomotherapy Unit. Helical (Spiral) Tomotherapy. MVCT of an Anesthetized Dog with a Sinus Tumor

Normal tissue dose in pediatric VMAT Piotr Zygmanski

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

Flattening Filter Free beam

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

Clinical experience with TomoDirect System Tangential Mode

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy

Contributors to this Talk

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

NCCN GUIDELINES ON PROTON THERAPY (AS OF 4/23/18) BONE (Version , 03/28/18)

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

9.5. CONVENTIONAL RADIOTHERAPY TECHNIQUE FOR TREATING THYROID CANCER

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

Borges C 1, Zarza- Moreno M 2, Teixeira N 2, Vaz P 3 1

Limits of Precision and Accuracy of Radiation Delivery Systems

Optimization of RapidArc for Head-and-Neck Radiotherapy. Jessica Emily Salazar. Department of Medical Physics Duke University.

Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD. Barbara Agrimson, BS RT(T)(R), CMD

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Transcription:

Intensity Modulated RadioTherapy A clinical application of a small accelerator University Medical Center Groningen A.A. van t Veld PhD I. Hoveijn PhD part 1 part2 CERN/KVI accelerator school, Zeegse, June 1 st 2005

2 Aims Introduction to radiotherapy The place of IMRT in radiotherapy The place of linac design in IMRT Realization of IMRT IMRT clinical examples

Mechanism of radiotherapy Treatment beam Photons Charged particles treatment beam Ionization tracks Damage to DNA

Linac: multiple fractions Introduction: a patient s view Localisator CT Simulator

Linac: multiple fractions Behind the screens Localisator CT Treatment planning Simulator

Treatment planning: step 1 Definition of targets and critical structures Brain Eyes Parotids Target

Treatment planning: step 1

8 Treatment planning: step 2 Design of treatment technique Number of beams and their directions Modality: photons/electrons and energy Design of multiple beams Beam shape Design of treatment plan Weighting of beam contribution Example Nasopharynx + bilateral neck nodes Max. 85% dose (50 Gy) to spinal cord 10 beams (4 shown) BTW: why so many beams?

By the way: why so many beams?? Single beam Multiple beams 160% 115% 100% 90% 100% 80% 60% 40% Very high dose to normal tissue Inhomogeneous target dose Accepted dose to normal tissue Homogeneous target dose

Treatment beams in Beam s-eye-view* Lateral Posterior *Projection of the patient as seen by the linac target

Treatment beams in Beam s-eye-view Lateral oblique Caudal

Treatment planning: step 3 Calculate dose distribution

Treatment planning: step 4 Evaluate dose distribution Adapt treatment plan (step 2) until acceptable

Treatment planning: step 4 Acceptable spinal cord dose 50% 70% 80% 90% 95% 100% Conformality to target 95%

Treatment plan = linac recipe Photon or electron beams 6 degrees of freedom... all around the isocentre treatment beam

Treatment planning: a step further needed No sparing of parotid gland Acceptable spinal cord dose 50% 70% 80% 90% 95% 100% Conformality to target 95%

Radiotherapy develops towards... Progress in radiotherapy depends on three areas in conjunction: Medicine Medical knowledge Dose calculation Technical facilities Physics Engineering

Radiotherapy develops towards... more conformal treatment 1983 1995 Beam s-eye-view with simple dose calculation Beams must conform to target MLC: Multi-Leaf Collimator allows more and better shaped beams Dose calculation with physics of linac model High dose must conform to target

Radiotherapy develops towards... IMRT Homogeneous fluence/beam Multi-Leaf Collimator allows modulation of a beam Intensity modulated radiotherapy (IMRT)

Radiotherapy develops towards IMRT 1985 1995 2000 Beam s-eye-view with simple dose calculation Beams must conform to target Dose calculation with physics of linac model High dose must conform to target Math. optimization & linac construction Dose distribution must conform to constraints

The place of IMRT in radiotherapy Spinal cord: < 30 Gy Target 2: > 50 Gy Target 1: > 60 Gy IJORBP 51, 880 (2001)

The place of linac design in IMRT Linear accelerator

Linac construction Linear accelerator Vacuum technology High-voltage circuits RF wave guide (Fine) mechanics Electronic control circuits

Linac construction Linear accelerator Vacuum technology High-voltage circuits EM wave guide (Fine) mechanics Electronic control circuits Rotatable over 360 In-house maintenance & support 5 engineers automatic checks (servo) weekly & monthly checks

Wave guide and flight tube

Bending magnet, electron window

Filter carrousel and monitor ion chamber

Housing of 40 leafs of MLC with motors

Multi-Leaf Collimator (Elekta BM)

MLC motors

33 The place of linac design in IMRT Better isocentric stability: 1 mm Fast beam startup: coil sets magnetron plunger Beam starting stability: slitless without servos Multi-leafs: fast change beam shape Multi-leaf specification: leakage, travel range, speed Leaf calibration: field junction dose Geometry and materials: must be well-known for dose calculation in treatment planning system

Improved mechanics and gantry motors

35 Dose calculation and linac geometry Construction of Elekta Sli linac model for calculation of a 6 MV-X 3x3cm 2 photon beam BEAM Monte Carlo model focus opening of prim. collimator flattening filter monitor chamber backscatter plate MLC (not visible) backup coll. lower (X) coll.

36 Dose calculation 1000 histories (= electrons on target) Construction of Elekta Sli linac model Photon exiting linac head Characteristics of exiting photons is determined by linac geometry

37 Dose calculation and linac geometry Linac model in treatment planning system should yield: 2D energy fluence distribution.... i.e. the number of particles.... times their energy.... for all relevant linac parts.... at actual field shape..

38 Dose calculation and linac geometry Treatment planning system should distinguish Head scatter contribution from linac head components Based on dose-point s-eye-view backprojection MU calculation including backscatter into monitor chamber Focus Flatness filter Focus Flatness filter Monitor chamber Collimator Collimator Collimator Collimator Dose point (x,y,z)

39 Two other possibilities for IMRT Tomotherapy: CT-scan and linac in one CyberKnife: linac on a robotic arm Tomotherapy at John Hopkins CyberKnife

40 Conclusions first part IMRT offers new possibilities to better spare critical organs and/or enhance tumor dose The design of the linear accelerator plays a critical role in: facilitating new treatment techniques treatment accuracy dose calculation Maintenance and quality control of RT apparatus such as a linac is of eminent importance