Study on the control of variable resistance for isokinetic muscle training system

Similar documents
Design and Dynamic Modeling of Flexible Rehabilitation Mechanical Glove

DESIGN AND IMPLEMENTATION OF A MECHATRONIC SYSTEM FOR LOWER LIMB MEDICAL REHABILITATION

Estimation of the Upper Limb Lifting Movement Under Varying Weight and Movement Speed

AT89C51 Microcontroller Based Control Model for Hybrid Assistive Limb (Knee )

EMG-Driven Human Model for Orthosis Control

Motor Control in Biomechanics In Honor of Prof. T. Kiryu s retirement from rich academic career at Niigata University

Q: What is the relationship between muscle forces and EMG data that we have collected?

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

DEVELOPMENT OF WEARABLE MASTER-SLAVE TRAINING DEVICE FOR UPPER LIMB CONSTRUCTED WITH PNEUMATIC ARTIFICIAL MUSCLES

Musculoskeletal System. Terms. Origin (Proximal Attachment) Insertion (Distal Attachment)

2282. Design of a bionic-inspired exoskeleton robot for lower limb assist

Journal of Applied Research and Technology

Dynamic Dumbbell - Novel Training Machine with Programmable Exercise Load

Machines. Design, Modeling and Real-Time Control of Advanced Exercise

Design and Preliminary Validation of an EMG-driven Control Strategy for a Twisted String Actuated Elbow Flexion Assistive Device

Biomechanics of Running State Protection of the Measurement and Evaluation System

Design and Implementation study of Remote Home Rehabilitation Training Operating System based on Internet

Upper limb biomechanical study of driving task based on AnyBody software

Development of Mirror Image Motion System with semg for Shoulder Rehabilitation of Post-stroke Hemiplegic Patients

A PERCEPTUAL MOTOR CONTROL MODEL BASED ON OUTPUT FEEDBACK ADAPTIVE CONTROL THEORY

EDUCATION AND QUALIFICATION

A Musculoskeletal Model-based Assistance-As-Needed Paradigm for Assistive Robotics

DEVICE FOR MUSCLE COORDINATION IMPROVEMENT

WIRELESS BODY AREA SENSOR NETWORK FOR SOLDIER SYSTEM.

PEMP-AML2506. Day 01A. Session Speaker Dr. M. D. Deshpande. 01A M.S. Ramaiah School of Advanced Studies - Bangalore 1

A Haptic Control Interface for a Motorized Exercise Machine

Design Considerations of a Human Arm Exoskeleton

Analysis of EMG and Biomechanical Features of Sports Aerobics Movements

Design and Control of a Robotic Assistive Device for Hand Rehabilitation (RAD-HR)

Fast Simulation of Arm Dynamics for Real-time, Userin-the-loop. Ed Chadwick Keele University Staffordshire, UK.

Analysis of Human Standing-up Motion Based on Distributed Muscle Control

A NOVEL ALGORITHM TO PREDICT KNEE ANGLE FROM EMG SIGNALS FOR CONTROLLING A LOWER LIMB EXOSKELETON

IEEE/ASME TRANSACTIONS ON MECHATRONICS, VOL. 2, NO. 4, DECEMBER

Chapter 14 Training Muscles to Become Stronger

Design of the HRV Analysis System Based on AD8232

Design of Palm Acupuncture Points Indicator

Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering

CHAPTER 9 BIOMECHANICS OF PHYSICAL ACTIVITY. Kathy Simpson

Biomechanics of Physical Activity

Chapter 20: Muscular Fitness and Assessment

3-DOF Parallel robotics System for Foot Drop therapy using Arduino

ECHORD call1 experiment MAAT

Study on a Footwork Training and Testing System

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION MARCH

The Human Machine: Biomechanics in Daily Life.

Verification of Immediate Effect on the Motor Function of a Plegic Upper Limb after Stroke by using UR-System 2.2

Available online at ScienceDirect. Procedia Computer Science 42 (2014 ) 78 84

Research on the motion characteristic of elbow joint angle based on the semg of single muscle

Investigation of Human Whole Body Motion Using a Three-Dimensional Neuromusculoskeletal Model

DATA INTERPRETATION AND ANALYSIS

Page 1 of 5 7/24/2013. YI-NING (WINNIE) WU, PH.D. Assistant Professor Department of Physical Therapy

Development of novel algorithm by combining Wavelet based Enhanced Canny edge Detection and Adaptive Filtering Method for Human Emotion Recognition

Biomechanics of Physical Activity

EMG Signals for Co-Activations of Major Lower Limb Muscles in Knee Joint Dynamics

Intelligent Frozen Shoulder Self-Home Rehabilitation Monitoring System

International Journal on Bioinformatics & Biosciences (IJBB) Vol.6, No.3/4, December 2016

New methods for the simulation with finite element of the human elbow

emg signals characterization in three states of contraction by fuzzy network and feature extraction springerbriefs in applied sciences and technology

A Comparison of a Multi body Model and 3D Kinematics and EMG ofdouble leg Circle on Pommel Horse

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects

CHAPTER 11 UNIVERSITY OF DENVER

TRAINING IN SPORTS. Key Points :

Electromyography II Laboratory (Hand Dynamometer Transducer)

A new approach to muscle fatigue evaluation for Push/Pull task

University of Cyprus Biomedical Imaging and Applied Optics. ECE 370 Introduction to Biomedical Engineering. Principles of Biomechanics

Wearable Hand Rehabilitation Robot Capable of Hand Function Assistance in Stroke Survivors*

Biomechanics of Skeletal Muscle and the Musculoskeletal System

Biomechanics of Resistance Training. Tutor: Phil Watkins

Doctoral School on Engineering Sciences Università Politecnica delle Marche

Hand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited

Learning and Robotic Imitation of Therapist s Motion and Force for Post-disability Rehabilitation

Simulation of Tremor on 3-Dimentional Musculoskeletal Model of Wrist Joint and Experimental Verification

NZQA Expiring unit standard 7026 version 4 Page 1 of 7. Apply knowledge of functional anatomy and biomechanics

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011

PoS(ISCC2015)036. The Research and Design of Children's Dental Treatment Machine Based on Ergonomics. Speaker. Yingjun Su1

Control of Finger Forces during Fast, Slow and Moderate Rotational Hand Movements

differentiate between the various types of muscle contractions; describe the factors that influence strength development;

A Human Machine Interface Design to Control an Intelligent Rehabilitation Robot System

Orbital 360. Introducing: The Orbital 360. Joseph Noel Office: (515) NW 5 th Street Ankeny, IA 50023

Research Article Research on Safety and Compliance of a New Lower Limb Rehabilitation Robot

ADVANCED BIOMECHANICS - KINES 484 Spring Semester, Summary of Review Questions

DMD4DMD (Dystrophy Monitoring Device for Duchenne Muscular Dystrophy)

A hybrid approach for identification of root causes and reliability improvement of a die bonding process a case study

WEARABLE MASTER-SLAVE TRANING DEVICE FOR LOWER LIMB CONSTRUCTED WITH PNEUMATIC RUBBER ARTIFICIAL MUSCLES

ADVANCES in NATURAL and APPLIED SCIENCES

LOWER limb cycling by means of functional electrical

Developing a Game-Based Proprioception Reconstruction System for Patients with Ankle Sprain

Navigator: 2 Degree of Freedom Robotics Hand Rehabilitation Device

Five-Fingered Assistive Hand with Mechanical Compliance of Human Finger

Development of FES-cycling System with Network Capability for Multi-Center Clinical Studies

AN EXOSKELETAL ROBOT MANIPULATOR FOR LOWER LIMBS REHABILITATION

Objective research on tongue manifestation of patients with eczema

Smart. Training. Developing advanced exercise machines

CONTROL OF THE BOUNDARY CONDITIONS OF A DYNAMIC KNEE SIMULATOR

sensors ISSN

NIH Public Access Author Manuscript J Intell Mater Syst Struct. Author manuscript; available in PMC 2008 June 11.

Part I Muscle: The Motor

Exoskeletons: Reducing joint and muscle loads while performing difficult tasks

IDENTIFYING the mechanical properties of the human

PLEASE DO NOT REMOVE THIS PAGE

Transcription:

Technology and Health Care 25 (2017) S45 S52 DOI 10.3233/THC-171305 IOS Press S45 Study on the control of variable resistance for isokinetic muscle training system Lan Wang, Zhenyuan Zhang, Yi Yu and Guangwei Chen College of Mechanical and Electrical Engineering, Harbin Engineering University, Harbin, Heilongjiang, China Abstract. BACKGROUND: Isokinetic muscle strength training is presently the most advanced method of muscle strength training. However, the existing control schemes of the training equipment are usually limited to the structure of the brake. OBJECTIVE: In order to solve this problem, this paper presents a solution to an isokinetic system based on the force control of a DC servomotor. METHODS: A new fuzzy impedance nonlinear controller is designed by analyzing the relevant requirements of isokinetic motion. A series of force tracking comparison experiments between a fuzzy PI controller and a classical PI controller are studied. In addition, some strength training experiments employing different driving forces and target speeds are also conducted. RESULTS: The results demonstrate the effectiveness of this fuzzy impedance force tracking control strategy. CONCLUSION: Using the aforementioned methods, a comprehensive motion algorithm was designed. Keywords: Isokinetic muscle strength training, impedance control, fuzzy control, rehabilitation training 1. Introduction With the developments of modern rehabilitation medicine, the techniques of isokinetic muscle strength measurement and training in muscle strength recovery are garnering considerable attention. Isokinetic muscle strength training is characterized by constant speed and adjustable resistance, which results in the best effect of strength training at any position of the joint [1]. With the help of the definition of isokinetic exercise, it is apparent that, no matter how much tension muscle generates, the movements of affected limbs are always carried out at a predetermined speed [2]. Isokinetic muscle testing and training are widely used in sports medicine, orthopedics, and rehabilitation medicine. Furthermore, isokinetic exercise training was able to significantly improve chronic stroke survivors strength and gait speed without concomitant increases in tone. Recently, some researchers have studied an isokinetic instrument based on the principle of brakes. Dong et al. [3] proposed portable rehabilitation equipment based on a magnetorheological damper, which changes the magnetic field by means of an adaptive controller and subsequently changes the state of the magnetorheological fluid, thereby resulting in a match resistance. This new form of damper provided a Corresponding author: Zhenyuan Zhang, College of Mechanical and Electrical Engineering, Harbin Engineering University, No. 145 Nantong Street, Nangang District, Harbin 150001, Heilongjiang, China. Tel.: +86 18004502686; Fax: 054182519710; E-mail: lhl2hww@163.com. 0928-7329/17/$35.00 c 2017 IOS Press and the authors. All rights reserved This article is published online with Open Access and distributed under the terms of the Creative Commons Attribution Non- Commercial License (CC-BY-NC 4.0).

S46 L. Wang et al. / Study on the control of variable resistance for isokinetic muscle training system Fig. 1. The overall scheme of isokinetic training system. new method for developing isokinetic training devices. Kikuchi et al. [4] developed an upper limb isokinetic rehabilitation device based on an electrorheological damper, and the related training effects were studied through experiments. Nikitczuk et al. [5] developed a knee rehabilitation device called AKROD, and some comparison experiments between AKROD and Biodex in isokinetic and isotonic contraction were conducted. Wang et al. [6] developed an isokinetic training device based on the principle of a throttle brake, which could change the resistance of the liquid flow by changing the orifice size of the liquid flow. Additionally, a controllable resistance, as required by isokinetic devices, can be obtained. The aforementioned studies are all based on the principle of brakes. However, for some rehabilitation equipment, this approach will result in increased structural complexity. Therefore, this paper proposes a new muscle rehabilitation method based on the force tracking control of a DC servomotor, which benefits the expansion of isokinetic training from special isokinetic muscle training devices to external skeleton rehabilitation robots. Moreover, this method can simultaneously reduce the cost of an isokinetic apparatus, which will help promote a wide use of isokinetic training. 2. Design of rehabilitation system The overall scheme of the isokinetic training system is shown in Fig. 1. When the user exerts a driving force on the connecting rod of the rehabilitation device, the connecting rod rotates. The speed and armature current of the servomotor are collected by using an encoder and a current sensor, respectively. Once the speed of motion reaches the target speed, the system will generate resistance to automatically

L. Wang et al. / Study on the control of variable resistance for isokinetic muscle training system S47 maintain a constant speed. Although the user changes the joint driving torque, the control system can also rebalance the active torque and the matching torque. There are several methods for obtaining the matching torque [7 9]; however, these methods require additional sensors to measure the relevant data. For this point, a simple and effective method is given in this paper, such that it can take a small deviation of velocity as the basis for predicting the matching torque. As for the given matching torque of tracking control, it is often indirectly implemented with a current closed loop in practice. Therefore, an integral part must be used in the force control loop [10]. 3. Design of fuzzy control The isokinetic training system is a man-machine coupling system. In the analysis, the effect of the human body on the system is simplified as the external torque. The training system can be regarded as a mass spring damper system. The torque balance equation of the model is given below: J θ + B θ + Kθ = M (1) where J, B, K, and M represent the total moment of inertia, the damping coefficient, the stiffness, and the total torque of the system, respectively. The system contains the torque generated by the motor and the external torque on the motor shaft. In addition, the effect of the heavy moment of inertia on the system is also considered. Thus, the equation can be given as follows: M = M m + M L + M f (2) where, M m, M L and M f represent the motor torque, the external torque on the motor shaft and the compensating torque, respectively. Because the system needs to provide a compliant resistance, an impedance force tracking control algorithm is used [11]. The basic equation is given below: J d ( θ d θ) + B d ( θ d θ) + K d (θ d θ) = M d (3) where θ d, θ, θd, θ, θd, and θ represent the expected acceleration, the actual acceleration, the expected velocity, the actual velocity, the expected position, and the actual position, respectively. During isokinetic exercise, the expected acceleration is equal to zero. Because the actual acceleration is also very small, the inertia moment is ignored. Moreover, the expected position is not planned in isokinetic exercise. Furthermore, isokinetic exercise requires that the resistance be equal to zero when the speed is less than the target speed. Therefore, a nonlinear link is introduced in the impedance controller. In order to achieve optimal control, a fuzzy damping controller is designed. The impedance control equation can be modified as follows: (B d + B d )( θ d θ) = M d (4) According to the human skeletal muscle model, the joint torque is related to muscle force and the moment arms of joint motor tendons [12 14], which makes matching the torque more complicated. Thus, a fuzzy PI controller is adopted to more accurately track the trajectory of the joint moment. By

S48 L. Wang et al. / Study on the control of variable resistance for isokinetic muscle training system Fig. 2. The block diagram of fuzzy impedance control scheme. controlling the armature current, the output torque of the motor is indirectly controlled. The following is the output torque equation of the controller: M d = C m [(K p + K p )(I d I r ) + (K i + K i ) (I d I r )] (5) where, C m, K p, K i, I d and I r represent the motor torque constant, the proportional gain, the integral gain, the given current and the fed-back current, respectively. The structure of the fuzzy impedance controller is shown in Fig. 2. The controller includes a fuzzy impedance part, a fuzzy PI part, and a compensation link. In this paper, the experimental platform is affected by a small weight torque, so the compensation moment will be set as zero. According to the performance requirements of the system, the domain of velocity error, the change rate of velocity error, and the increment of damping parameter are set as [ 2, 0], [ 0.5, 0.5], and [0, 5], respectively. The inputs of the controller are the given current and its change rate. By analyzing the optimal controller parameters for different step signals, the fuzzy rules are determined. Because the maximum output current of the motor is 6A, the domain of the given current is [ 6, 0]. Combined with experience, the domain of the change rate of I d, the domain of K p, and the domain of K i are set as [ 0.5, 0.5], [300, 700], and [10.3, 16.5], respectively. 4. Experiments and results This experimental platform consists of a rehabilitation device, a drive circuit, and a dspace HIL simulation platform, as shown in Fig. 3. The experiments are formed by a force tracking experiment and an isokinetic muscle strength training experiment, which test the performance of the inner loop and outer loop, respectively.

L. Wang et al. / Study on the control of variable resistance for isokinetic muscle training system S49 Table 1 Statistical results of current tracking experiments with different control algorithms Subject Controller type 0.2 A 1 A 2 A 3 A 4 A 5 A Maximum overshoot (%) PI 0 1 0 0 13 20 FPI 0 4 3 1.5 3 2 Rise time (ms) PI 450 200 70 150 50 70 FPI 130 50 60 60 50 80 4.1. Force tracking experiment Fig. 3. Isokinetic training platform. The force tracking experiment is primarily used to test the response of the controller under different step signals. The classic PI controller is selected as the comparison group. The proportional gain and the integral gain of the classic PI controller are 540 and 13.3, respectively. The domain of I d determines the amplitude of the step signal, which is set to 0.2 A, 1.0 A, 2.0 A, 3.0 A, 4.0 A, and 5.0 A. The responses are shown in Fig. 4, and Table 1 displays the overshoots of the response and the rise times. In Table 1, it can be seen that neither the response of the FPI controller or the PI controller overshoot when the step signal is 0.2 A, and the rise time of the PI controller is 450 ms, which is much longer than the rise time of the FPI controller. When the given current is set to 1 A, 2 A, and 3 A, the maximum overshoot of the PI controller is less than 1%, but the rise time of the FPI controller is better. When the given current is set to 4 A and 5 A, the maximum overshoot of the PI controller reaches 13% and 20%, respectively, beyond the reasonable range of the system. As mentioned above, there is evidence that the FPI controller is better than the PI controller. 4.2. Isokinetic training experiment The isokinetic training experiment is used to verify the effectiveness of the control algorithm. Taking into consideration the reliability and the feasible operability of the experiment, three muscular, healthy males are chosen as the experimental subjects. Their ages are 24, 25, and 26 years old. The experiment consists of two parts. During the first part of the experiment, the subject shakes the handle using the different force, and the target speed is set as 20 r/min. The response is shown in Fig. 5. Figures 5(a) and (d) show that when the given current remains around 1.5 A, the speed error fluctuates between 5% and 0%. As shown in Figs 5(b) and (e), when the given current maintains around 2.5 A,

S50 L. Wang et al. / Study on the control of variable resistance for isokinetic muscle training system Fig. 4. Results of the current tracking experiments. Amplitude is set at (a) 0.2 A, (b) 1.0 A, (c) 2.0 A, (d) 3.0 A, (e) 4.0 A, and (f) 5.0 A. Fig. 5. Results of the first part of the isokinetic training experiment. (a) The speed of a lesser torque. (b) The current of a moderate torque. (c) The speed of a larger torque. (d) The current of a lesser torque. (e) The speed of a moderate torque. (f) The current of a larger torque. the speed deviation fluctuates between 5% and 2.5%, and the error change rate is also fairly small. As depicted in Figs 5(c) and (f), when the given current remains 4 A, the speed deviation fluctuates between 2.5% and 10%, and the change rate is relatively large. Throughout the above data, when the given current is 1 A or 2.5 A, the speed is relatively stable, and the current follows better. When the given current remains at about 4 A, the velocity deviation becomes large, and a relatively large fluctuation

L. Wang et al. / Study on the control of variable resistance for isokinetic muscle training system S51 Fig. 6. Results of the second part of isokinetic training experiment. (a) The speed that target speed is set to 20 r/min. (b) The speed that target speed is set to 30 r/min. (c) The speed that target speed is set to 40 r/min. (d) The current that target speed is set to 20 r/min. (e) The current that target speed is set to 30 r/min. (f) The current that target speed is set to 40 r/min. is generated. In Fig. 5(f), the current tracking error becomes large. This is because the response speed of the system is slow when the given current is large. The experimental results verify the ability of the system to maintain a certain speed with different external forces. In the second part of this experiment, the target speed is set as 20 r/min, 30 r/min, and 40 r/min, and the driving force is changed from small to large. The control effect is shown in Fig. 6. As shown in Figs 6(a) and (d), when the target speed is set at 20 r/min and the given current gradually increases, the speed deviation remains in the 5% 1.5% range, and the change rate is very small. Figures 6(b) and (e) reveal that when the target speed is set to 30 r/min, the speed error fluctuates between 5% and 1%. As depicted in Figs 6(e) and (f), when the target speed is set to 40 r/min, the speed deviation fluctuates between 2.5% and 0%, and the change rate is relatively large. The above analysis demonstrates that speed deviation remains within a reasonable range, and the speed remains relatively stable with a gradual increase in active torque. Throughout the cases at different target speeds, the results also reveal that the velocity deviation remains within an allowable range. The experiments further verify the ability of the system to maintain a target speed. 5. Conclusions and future works The traditional control strategy of an isokinetic muscle strength training instrument is limited to the structure of the brake. This paper, however, presents a new solution for solving this problem for isokinetic systems, and this new method is based on the force control of a DC servomotor. A fuzzy impedance force tracking controller is proposed in this new scheme, and the real-time adjustment of system resistance ensures that the system speed is essentially equal to the given speed. Then, a series of force tracking experiments and isokinetic muscle strength training experiments were conducted, and the results demonstrate the effectiveness of the control strategy.

S52 L. Wang et al. / Study on the control of variable resistance for isokinetic muscle training system Future work will focus on the inspection and improvement of the control effect because there is a ripple in the system when the external force is larger, and the change rate of the velocity deviation increases. Acknowledgments This research is supported by grants from the National Natural Science Foundation of China (grants 51405095) and Harbin Foundation (grants 2014RFXXJ101). Conflict of interest None to report. References [1] Song YL. Isokinetic muscle rehabilitation and the approach to realizing isokinetic motion, Journal of Shanghai Dianji University, 2006 (5), 5-9. [2] Huang ZP, Yin Y, Liu M. Research evolution of the isokinetic technology in testing and training, Sport science: Guang xi, 2011 (4), 52-58. [3] Dong S, Liu KQ, Sun JQ. Rehabilitation device with variable resistance and intelligent control, Medical Engineering and Physics, 2005, 27(3), 249-255. [4] Kikuchi T, Furusho J, Oda K. Development of isokinetic exercise machine using ER brake, Proceedings of IEEE International Conference on Robotics and Automation, Taipei, Taiwan, 2003,214-219. [5] Nikitczuk J, Weinberg B, Canavan PK. Active knee rehabilitation orthotic device with variable damping characteristics implemented via an electrorheological fluid, Mechatronics IEEE/ASME Transactions on, 2010, 15(6), 952-960. [6] Wang Y, Shen B, Song Y. Development of Key Device for Isokinetic Human Muscle Rehabilitation System, Journal of Shanghai Dianji University, 2011. [7] Li HJ, Liu H, Zhang X. Development of estimation of the muscle force distribution of joint, Journal of Beijing Sport University, 2013. [8] Pang M, Wang J, Fu J et al. Interaction force prediction between human and environments based on surface EMG, Journal of Huazhong University of Science and Technology, 2015. [9] Ryait HS, Arora AS, Agarwal R. SEMG signal analysis at acupressure points for elbow movement, Journal of Electromyography and Kinesiology Official Journal of the International Society of Electrophysiological Kinesiology, 2011, 21(5): 868-876. [10] Liu YW, vwang GX, Li J, Qi ZG. Design problems of force control systems, Electric Machines and Control, 2011, 15(4), 98-102. [11] Xu GZ, Song AG, Li HJ. Experimental study on fuzzy-logic-based impedence control for upper-limb rehabilitation robot, Robot, 2010, 32(6), 792-798. [12] Hackett L, Reed D, Halaki M. Assessing the validity of surface electromyography for recording muscle activation patterns from serratus anterior, Journal of Electromyography and Kinesiology Official Journal of the International Society of Electrophysiological Kinesiology, 2014, 24(2), 221-227. [13] Bai J. An elblow biomechanical model on semg, M. A. Dissertation, Harbin Institute of Technology, 2014. [14] Zhang ZH. Study of bone-muscle modeling and muscle force prediction method of human upper limb, M. A. Dissertation, Tianjin University, 2012.