Comparative study on the diagnostic values of different ultrasound technologies for malignant thyroid nodules

Similar documents
Can Color Doppler Sonography Aid in the Prediction of Malignancy of Thyroid Nodules?

Imaging-cytology correlation of thyroid nodules with initially benign cytology

Role of ultrasonography in recognition of malignant potential of thyroid nodules on the basis of their internal composition

Sonographic Differentiation of Thyroid Nodules With Eggshell Calcifications

Correlation CEUS & Sono Elastography for Malignant Thyroid Nodule Evaluation

Comparison of diagnostic values between ultrasound elastography and ultrasound guided thyroid nodular puncture in thyroid nodules

Contrast-enhanced ultrasound of solitary thyroid nodules - qualitative and quantitative evaluation: initial results

Elastography predicts thyroid cancer: comparison of two methods

Elastography. White Paper

ShearWave elastography in lymph nodes

ISSN X (Print) Research Article. *Corresponding author Dr Kumud Julka

Practical Approach to Thyroid Nodules:Ultrasound Criteria for Performing FNA Revisited

Int J Clin Exp Med 2017;10(12): /ISSN: /IJCEM Lijie Zhou 1, Lijuan Quan 1, Wenjun Zhu 1, Jianqi Ni 2

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

Warinthorn Phuttharak*, Charoonsak Somboonporn, Gatenapa Hongdomnern

CLINICAL GUIDELINES. Introductory notes:

Su-kyoung Jeh, MD 1 So Lyung Jung, MD 2 Bum Soo Kim, MD 2 Yoen Soo Lee, MD 3

Int J Clin Exp Med 2018;11(3): /ISSN: /IJCEM Shuhao Deng, Quan Jiang, Yicheng Zhu, Yuan Zhang

Taller-Than-Wide Sign of Thyroid Malignancy: Comparison Between Ultrasound and CT

Real-time elastography of parotid gland masses: the value of strain ratio for the differentiation of benign from malignant tumors

Diagnostic Value of Ultrasound-detected Calcification in Thyroid Nodules

Role of sonoelastography in the evaluation of superficial soft tissue lesions: qualitative and quantitative study

Original Article Analysis of contrast-enhanced ultrasound in the differential diagnosis of papillary thyroid cancer and thyroid nodules

Predicting the Size of Benign Thyroid Nodules and Analysis of Associated Factors That Affect Nodule Size

Differentiating Benign from Malignant Cervical Lymph Nodes with Sonoelastography

Innovations in Ultrasound & Breast Cancer Imaging

Sonographic differentiation of benign and malignant thyroid nodules: Prospective study

Research Article Utility of Shear Wave Elastography for Diagnosing Chronic Autoimmune Thyroiditis

Biomedical Research 2017; 28 (21): ISSN X

Principal Site Investigator ENHANCE (Evaluation of Thyroid FNA Genomic Signature) study: An IRB approved study with funding to Rochester Regional

Does Ultrasound Elastography Improve the Diagnostic Accuracy of Fine Needle Aspiration Cytology in Predicting Malignancy in Thyroid Nodules?

Byung Ihn Choi, M.D. Department of Radiology Seoul National University Hospital

The Comparison of Scintigraphic and Ultrasonographic Evaluation Criteria of Thyroid Nodules with Histopathologic Findings

Thyroid Nodules: US Risk Stratification. Alex Tessnow, MD, FACE, ECNU University of Texas Southwestern Associate Professor of Medicine Dallas, Texas

Compressibility of Thyroid Masses: A Sonographic Sign Differentiating Benign From Malignant Lesions?

Characterization and significance of MUC1 and c-myc expression in elderly patients with papillary thyroid carcinoma

Thyroid Nodules: US Risk Stratification and FNA Guidelines

Original Article Ultrasonographic characteristics and BI-RADS-US classification of BRCA1 mutation-associated breast cancer in Guangxi, China

Sonographic Features of Thyroid Nodules & Guidelines for Management

Ultrasonic strain imaging made by speckle tracking of B-mode image

Diagnostic TRUS Elastography of the Prostate

Evaluation of thyroid nodules: prediction and selection of malignant nodules for FNA (cytology)

THYROID NODULES: THE ROLE OF ULTRASOUND

Does elastography change the indication to biopsy? IBDC

The learning curve of real time elastosonography: a preliminary study conducted for the assessment of malignancy risk in thyroid nodules

AACE/ACE Advanced Endocrine Neck Ultrasound Training Course 2016

Correlation analyses of thyroid-stimulating hormone and thyroid autoantibodies with differentiated thyroid cancer

Original Article Diagnosis significance of single high frequency ultrasonography and mammography and their combined examination on breast cancer

Quantification of solid hypo-echoic thyroid nodule enhancement with contrast-enhanced ultrasound

We evaluated the medical records of 1,015 patients who underwent surgery for primary breast cancer between February 2007 and August 2008 at St.

The Thyroid Imaging Reporting and Data System (TIRADS) for ultrasound of the thyroid : a pratical approach

Adina Alazraki, MD, FAAP Assistant Professor Radiology and Pediatrics Emory University and Children s Healthcare of Atlanta

Indications for Fine Needle Aspiration in Thyroid Nodules

Clinical Study B-Mode and Elastosonographic Evaluation to Determine the Reference Elastosonography Values for Cervical Lymph Nodes

Original Article Feasibility of fine-needle aspiration biopsy and its applications in superficial cervical lesion biopsies

EUS Elastography: Advances in Diagnostic EUS of the Pancreas

ArticleInfo. Spring School of Thyroidology organized by the Polish Thyroid Association 2014: abstracts of invited lectures

Imaging in Pediatric Thyroid disorders: US and Radionuclide imaging. Deepa R Biyyam, MD Attending Pediatric Radiologist

Introduction: Ultrasound guided Fine Needle Aspiration: When and how

Korean Thyroid Imaging Reporting and Data System features of follicular thyroid adenoma and carcinoma: a single-center study

Contents. Basic Ultrasound Principles and Terminology. Ultrasound Nodule Characteristics

The Efficiency of Ultrasound Elastography in the Differential Diagnosis of Thyroid Nodules

Thyroid Imaging Reporting and Data System (TI-RADS): the impact of Quantitative Strain Elastography for better stratification of cancer risks.

Sonographic Features of Benign Thyroid Nodules

Volume 2 Issue ISSN

Thyroid Nodule Risk Stratification and FNA Guidelines

Reliability of the ultrasound classification system of thyroid nodules in predicting malignancy

Differentiation of Thyroid Nodules With Macrocalcifications

Thyroid nodules with minimal cystic changes have a low risk of malignancy

THI-RADS. US differentiation of thyroid lesions.

THI-RADS. US differentiation of thyroid lesions.

Shear Wave Elastography In Characterization Of Liver Tumours

In adults, clinically palpable thyroid nodules are

Cancer incidence and patient survival rates among the residents in the Pudong New Area of Shanghai between 2002 and 2006

Quality Initiative Project assessing the impact of TIRADS on net number of thyroid biopsies and adherence of TIRADS-reporting by radiologists

Thyroid & Parathyroid glands Ultrasound evaluation.

Biomedical Research 2014; 25(3): ISSN X

Department of Ultrasound Diagnosis, Wenzhou Central Hospital, Wenzhou, P.R. China. Abstract

Update on Thyroid FNA The Bethesda System. Shikha Bose M.D. Associate Professor Cedars Sinai Medical Center

ONCOLOGY LETTERS 14: , Yantai Hospital of Traditional Chinese Medicine, Yantai, Shandong , P.R. China

Characteristics of thyroid nodules in infant with congenital hypothyroidism. Seoul, Korea

Screening of parathyroid gland by high frequency ultrasound and the relationship between recurrent urinary calculi and primary

Thyroid Nodules. Dr. HAKIMI, SpAK Dr. MELDA DELIANA, SpAK Dr. SISKA MAYASARI LUBIS, SpA

Oh, I get it, the TSH goes up and down

Sonographic Patterns of Benign Thyroid Nodules: Verification at Our Institution

Repeat Thyroid Nodule Fine-Needle Aspiration in Patients With Initial Benign Cytologic Results

Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules: New events

On the feasibility of speckle reduction in echocardiography using strain compounding

Biomedical Research 2017; 28 (13):

Ultrasound Physics & Doppler

Repeat Ultrasound-Guided Fine-Needle Aspiration for Thyroid Nodules 10 mm or Larger Can Be Performed 10.7 Months After Initial Nondiagnostic Results

of Thyroid Lesions Comet Tail Crystals

The role of elastosonography, gray-scale and colour flow Doppler sonography in prediction of malignancy in thyroid nodules

Thyroid & Salivary glands.

Role of Ultrasonography to Differentiate Benign and Malignant Thyroid Nodules in Correlation with Fine-needle Aspiration Cytology

Endocrinology and Metabolic Disorder Unit Regina Apostolorum Hospital

Thyroid Nodule. Disclosure. Learning Objectives P A P A P A 3/18/2014. Nothing to disclose.

Rapid thyroid nodule growth is not a marker for well-differentiated thyroid cancer

Reliability of the ultrasound classification system of thyroid nodules in predicting malignancy

Transcription:

910 Comparative study on the diagnostic values of different ultrasound technologies for malignant thyroid nodules XIAO-ZHU JIN 1*, WEI-WEI LU 2*, HAI-FENG ZHANG 3, YUAN-YUAN YAN 1 and XIAO-LE GU 1 1 Department of Ultrasonography, Zhengzhou Central Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan 450000; 2 Department of Ultrasonography, The First People's Hospital of Shangqiu, Shangqiu, Henan 476000; 3 Department of Radiology, Zhengzhou Central Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan 450000, P.R. China Received April 11, 2017; Accepted January 25, 2018 DOI: 10.3892/ol.2018.8706 Abstract. The present study compared and analyzed the diagnostic values of B-mode ultrasound and elasticity imaging technology for the identification of benign and malignant thyroid nodules. Ninety-four patients who were diagnosed with thyroid nodules by ultrasound were chosen. All patients were checked with B-mode ultrasound and ultrasound elasticity imaging technology before surgeries. Further, the post operative outcomes were compared with operation pathology. The pathological examination results were taken as the gold standard. The accuracy, sensitivity, specificity, positive predictive value and negative predictive values of combined ultrasound diagnosis were all obviously higher than those by the B-mode ultrasound and the ultrasound elastography method (P<0.05). In conclusion, as a new technology, ultrasound elasticity imaging technology has relatively high diagnositic value in identifying benign and malignant thyroid nodules. With its own advantages and limitations, the ultrasound elasticity imaging technology could effectively complement B-mode ultrasound, and improve the sensitivity, specificity and accuracy of ultrasound diagnosis for thyroid nodules. Introduction Thyroid nodule refers to a mass of abnormally proliferating cells with abnormal local hardness in thyroid (1). At present, ultrasonography of thyroid nodules mainly relies on B-mode ultrasound diagnosis. However, the diagnostic sensitivity and Correspondence to: Dr Xiao-Le Gu, Department of Ultrasonography, Zhengzhou Central Hospital Affiliated to Zhengzhou University, 195 Tongbai Road, Zhongyuan, Zhengzhou, Henan 450000, P.R. China E-mail: o52341283huang@163.com * Contributed equally Key words: B-mode ultrasound, elasticity imaging techniques, thyroid nodule, benign, malignant specificity by B-mode ultrasound is not high (2,3). Ultrasound elasticity imaging, as a new technology developed this year, can determine the mechanical characteristics of tissues in vitro (4). The application value of ultrasound elasticity imaging technology in breast cancer has been confirmed, but its applications in the diagnosis of benign and malignant thyroid nodules are relatively few. The present study compared diagnostic values of B-mode ultrasound and elasticity imaging for the identification of benign as well as malignant thyroid nodules. This modality helps to improve the diagnosis rate of benign and malignant thyroid nodules by ultrasound technology. Materials and methods General materials. Ninety-four confirmed cases (from January, 2011 to January, 2015) of thyroid nodules by ultrasound in Zhengzhou Central Hospital Affiliated to Zhengzhou University (Zhengzhou, China) were chosen for the study. There were 46 male and 48 female cases. The age of the patient ranged from 22-72 years and the average age was 43.5±4.5 years. Detection methods. Siemens Acuson Antares 5.0 Color Doppler Ultrasonic Diagnosis Apparatus (Siemens, Erlangen, Germany) and VF13-5 frequency conversion probe were adopted as the detection instrument. All study subjects were examined by B-mode ultrasound and ultrasound elastography. Patients were kept in supine position and were first given routine vertical and horizontal section scanning of the neck. Nodule forms, sizes, boundaries, internal echo, existence of calcification, surrounding acoustic halo, blood flow conditions and cervical lymph nodes were observed by two-dimensional ultrasound. Subjects were then analyzed by elasticity imaging mode. We tried to make the probe cling to the neck skin during the operation. It was better to make the nodule at the center of sample frame. The size of sample frame was supposed to be adjusted to about twice the size of the lesions. The probe was held by hand and made to slightly vibrate at masses at middle speed. We saved the picture, when stress figure on the device monitor was between 3-4 grades. The color changes of elasticity picture in the sample frame were observed (5).

JIN et al: DIFFERENT ULTRASOUND TECHNOLOGIES FOR MALIGNANT THYROID NODULES 911 Table I. The classification results and pathological diagnosis of thyroid nodule ultrasound elasticity. Benign ----------------------------=------------------------ Malignant -------------------------------------------------------------------------------------------------------------------------- Ultrasound Nodular Thyroid Papillary Follicular thyroid Non-hodgkin's elasticity grade goiter adenoma carcinoma carcinoma lymphoma Grade 0 7 6 0 0 0 Grade I 0 9 2 0 0 Grade II 10 12 1 0 0 Grade III 8 17 7 1 0 Grade IV 1 2 9 1 1 Total 26 46 19 2 1 Figure 1. Elasticity ultrasound imaging of the thyroid. Diagnostic criteria of B-mode ultrasound. The features of benign thyroid nodules were regular morphology, clear boundary, <1 aspect ratio, inside equal echo, high echo, with or without an echo, coarse calcifications, no rear echo reduction, no or a little blood flow. The resistive index of blood flow was <0.7. The features of malignant thyroid nodules included irregular forms, unclear boundary, the aspect ratio was 1, inside low echo, micro-calcification, rear echo reduction, rich blood flow. The resistive index of blood flow was 0.7. Diagnostic criteria of ultrasound elastography. We adopted the hardness-scoring standard recommended by the Hitachi Co. and took the 5 fractions method according to different nodule colors. One point, the cystic components predominated in nodules manifested by blue-green colors; 2 points, nodules and surrounding tissues manifested by evenly green color; 3 points, >50% and <90% nodules manifested by green color; 4 points, >50% and <90% nodules manifested by blue color; 5 points, >90% nodules manifested by blue color; 1-3 points indicated benign thyroid nodules, and 4-5 points indicated malignant thyroid nodules (6). Fig. 1 shows the elasticity ultrasound imaging of the thyroid. Statistical analysis. Data were analyzed and processed by SPSS 18.0 (SPSS, Inc., Chicago, IL, USA). Enumeration data were examined by χ 2 test. P<0.05 was considered to be statistically significant. Results Results of pathological findings. Among 94 thyroid nodules, there were 22 malignant nodules, including 2 cases of follicular thyroid carcinoma, 9 cases of papillary carcinoma and 1 case of metastatic carcinoma. Further, there were 72 benign nodules, including 26 cases of goiter nodules and 46 cases of thyroid adenoma (Table I). The B-mode ultrasound evaluation of benign and malignant thyroid nodules. The identification of benign and malignant thyroid nodules by the B-mode ultrasound showed 84.04% (79/94) accuracy, 77.27% (17/22) sensitivity, 86.11% (62/72) specificity, 62.96% (17/27) positive predictive value and 92.53% (62/67) negative predictive value. On the other hand, the ultrasound elastography showed 86.17 (81/94) accuracy, 81.82% (18/22) sensitivity, 87.50% (63/72) specificity, 66.67% (18/27) positive predictive value and 94.02% (63/67) negative predictive value. Further the identification of benign and malignant thyroid nodules by the combined ultrasound diagnosis showed 96.81% (91/94) accuracy, 95.45% (21/22) sensitivity, 97.22% (70/72) specificity, 91.30% (21/23) positive

912 Table II. Comparisons of the accuracy, sensitivity, specificity, positive predictive value and negative predictive value of the benign and malignant thyroid nodule among different methods. Pathological Pathological Pathological B-mode ---------------------------------------------------- Ultrasound ---------------------------------------------------- Combined ------------------------------------------------------ ultrasound Benign Malignant Total elastography Benign Malignant Total ultrasound Benign Malignant Total Benign 62 5 67 Benign 63 4 67 Benign 70 1 71 Malignant 10 17 27 Malignant 9 18 27 Malignant 2 21 23 Total 72 22 94 Total 72 22 94 Total 72 22 94 Sensitivity (%) - - 77.27 Sensitivity (%) - - 81.82 Sensitivity (%) - - 95.45 Specificity (%) - - 86.11 Specificity (%) - - 87.50 Specificity (%) - - 97.22 Positive predictive value (%) - - 62.96 Positive predictive value (%) - - 66.67 Positive predictive value (%) - - 91.30 Negative predictive value (%) - - 92.53 Negative predictive value (%) - - 94.02 Negative predictive value (%) - - 98.59 Accuracy (%) - - 84.04 Accuracy (%) - - 86.17 Accuracy (%) - - 96.81 predictive value and 98.59% (70/71) negative predictive value. The accuracy, sensitivity, specificity, positive predictive value and negative predictive values of combined ultrasound diagnosis were all obviously higher than those by the B-mode ultrasound method and the ultrasound elastography method (P<0.05). There were no significant differences between results of the B-mode ultrasound method and the ultrasound elastography method (P>0.05) (Table II). Discussion China has listed the thyroid nodule as a health examination item, as the detection rates are on the rise continuously. Five to 10% of these thyroid nodules are malignant nodules (7). The early diagnosis would contribute to increasing the cure rate, prolonging the survival time and improving the survival quality of patients. Thyroid nodules are relatively occult at early stage. Therefore, it is difficult to find the nodule completely by preliminary diagnosis. The B-mode ultrasound diagnosis could not effectively identify the nodule either, which is easy to be confused with the thyroid tissue. For a long time, ultrasound has been preferred for diagnosis of benign and malignant thyroid nodules. Thus, the B-mode ultrasound detection is not able to identify all types of benign or malignant thyroid nodules (2). The prime research target in imaging currently is to improve the detection rate and reduce the omission diagnostic rate of malignant thyroid nodules. The real-time ultrasound elastography is a newly developed ultrasound technology (8). This technology reflects the hardness of monitored tissues mainly by detecting tissue distortion degree by applying external pressure. Images are developed in accordance with hardness differences among tissues. Ultrasound elastography could provide information on elasticity, which is the basic mechanic property so as to provide a new way of identifying benign and malignant thyroid nodules. This study evaluated advantages and disadvantages of B-mode ultrasound and ultrasound elastography in identifying benign and malignant thyroid nodules. We combined the B-mode ultrasound with ultrasound elastography for diagnosis, and found that identification of benign and malignant thyroid nodules by the combined ultrasound showed good results. The accuracy was greatly improved which indicated that the elasticity imaging technology could raise the accuracy of identifying benign and malignant thyroid nodule by B-mode ultrasound. In the present study, we found that the accuracy, sensitivity, specificity and positive predicative value of combined ultrasound were all better than those of B-mode ultrasound and ultrasound elastography. Results above showed that there is no significant difference between the diagnostic accuracy of thyroid nodules by B-mode ultrasound and ultrasound elastography. Perhaps it is because the elasticity imaging technology could provide information related to tissue elasticity and is affected by many factors. Goertz et al (9) have compared the results of B-mode ultrasound and the elasticity imaging technology and found the latter showed no advantages over the former. However, the accuracy between the two technologies in diagnosis of thyroid nodules revealed no statistical significance. Ultrasound elasticity imaging is a technology aiming at tumor examinations and gives relatively ideal imaging effect of

JIN et al: DIFFERENT ULTRASOUND TECHNOLOGIES FOR MALIGNANT THYROID NODULES 913 tumors or diffused diseases. At present, most clinical studies suggested that B-mode ultrasound is better in the aspects of accuracy, sensitivity and specificity. However, ultrasound elastography is limited in its improvement. Therefore, in recent years, a number of literature data have focused on the diagnosis effects of B-mode ultrasound detection method combined with the elasticity imaging technology. All research indicated that combined detection has greatly increased the diagnosis sensitivity, specificity and positive predicative values, which in turn conform to our research results (10-12). Ultrasound elasticity imaging technology identified the hardness, elasticity and pathological characters of lesion tissues. So it could serve as the basis of pathological diagnosis. Its application in pathological diagnosis of breast diseases is relatively good. The identification accuracy of benign and malignant tissues reached 89.6-91.3% which is a relatively good directive significance for clinical diagnosis (10). However, thyroid nodule tissues are different from breast tissues as the density difference among benign and malignant nodules is smaller than that of breast tumors. So, the diagnosis accuracy of benign and malignant tissues is reduced. It is still a kind of significant iconography detection methods with wide application. There are many reliable reports on its individual application. Also, there are some controversial reports (11). In terms of the diagnosis of benign and malignant thyroid nodules, some scholars suggested that the elasticity imaging technology could not be used as an independent diagnosis method (5). Ultrasound elasticity imaging technology has its own advantages of identifying lesion nature. Ultrasound elasticity imaging could locate tumors and reveal the relationships between tumors and surrounding tissues. In recent years, the application of real-time tissue elastography (13-15) technology allowed recording of real-time color images. Judgment of the nature of the tumor could be more exact based on echo signal movement. The diagnosis effect would be further improved in the combination of ultrasound elasticity imaging with routine inspection. Therefore, it is more appropriate to take ultrasound elastography as an assisting detection method for B-mode ultrasound examination (16-18). To conclude, ultrasound elasticity imaging technology, as a new technology, has relatively high diagnotic value for identifying benign and malignant thyroid nodules. The ultrasound elasticity imaging technology could effectively complement B-mode ultrasound diagnosis, and improve the sensitivity, specificity and accuracy of ultrasound diagnosis of thyroid carcinoma. Acknowledgements Not applicable. Funding No funding was received. Availability of data and materials The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request. Authors' contributions XZJ contributed significantly to writing the manuscript and exam of patients by ultrasound. WWL and HFZ helped with B-mode ultrasound. YYY and XLG analyzed and interpreted ultrasound elastography result. All authors read and approved the final manuscript. Ethics approval and consent to participate The study was approved by the Ethics Committee of Zhengzhou Central Hospital Affiliated tot Zhengzhou University (Zhengzhou, China) and informed consents were signed by the patients and/or guardians. Consent for publication Not applicable. Competing interests The authors declare that they have no competing interests. References 1. Wong CK and Wheeler MH: Thyroid nodules: Rational management. World J Surg 24: 934-941, 2000. 2. Dudea SM and Botar-Jid C: Ultrasound elastography in thyroid disease. Med Ultrason 17: 74-96, 2015. 3. Frates MC, Benson CB, Charboneau JW, Cibas ES, Clark OH, Coleman BG, Cronan JJ, Doubilet PM, Evans DB, Goellner JR, et al; Society of Radiologists in Ultrasound: Management of thyroid nodules detected at US: Society of Radiologists in Ultrasound consensus conference statement. Radiology 237: 794-800, 2005. 4. Rago T, Santini F, Scutari M, Pinchera A and Vitti P: Elastography: New developments in ultrasound for predicting malignancy in thyroid nodules. J Clin Endocrinol Metab 92: 2917-2922, 2007. 5. Jiang Y, Li GY, Qian LX, Hu XD, Liu D, Liang S and Cao Y: Characterization of the nonlinear elastic properties of soft tissues using the supersonic shear imaging (SSI) technique: Inverse method, ex vivo and in vivo experiments. Med Image Anal 20: 97-111, 2015. 6. Li T, Zhou P, Zhang X, Ding M, Yuchi M and Li Y: Diagnosis of thyroid nodules using virtual touch tissue quantification value and anteroposterior/transverse diameter ratio. Ultrasound Med Biol 41: 384-392, 2015. 7. Mehrmohammadi M, Song P, Meixner DD, Fazzio RT, Chen S, Greenleaf JF, Fatemi M and Alizad A: Comb-push ultrasound shear elastography (CUSE) for evaluation of thyroid nodules: Preliminary in vivo results. IEEE Trans Med Imaging 34: 97-106, 2015. 8. Ophir J, Céspedes I, Ponnekanti H, Yazdi Y and Li X: Elastography: A quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging 13: 111-134, 1991. 9. Goertz RS: Ultrasound elastography. Radiologe 55: 949-955, 2015 (Ιn German). 10. Yoon JH, Yoo J, Kim EK, Moon HJ, Lee HS, Seo JY, Park HY, Park WJ and Kwak JY: Real-time elastography in the evaluation of diffuse thyroid disease: A study based on elastography histogram parameters. Ultrasound Med Biol 40: 2012-2019, 2014. 11. Zhuo J, Ma Z, Fu WJ and Liu SP: Differentiation of benign from malignant thyroid nodules with acoustic radiation force impulse technique. Br J Radiol 87: 20130263, 2014. 12. Sun J, Cai J and Wang X: Real-time ultrasound elastography for differentiation of benign and malignant thyroid nodules: A meta analysis. J Ultrasound Med 33: 495-502, 2014. 13. Udelsman R and Zhang Y: The epidemic of thyroid cancer in the United States: The role of endocrinologists and ultrasounds. Thyroid 24: 472-479, 2014. 14. Wells PN and Liang HD: Medical ultrasound: Imaging of soft tissue strain and elasticity. J R Soc Interface 8: 1521-1549, 2011.

914 15. Giovanella L, Clark PM, Chiovato L, Duntas L, Elisei R, Feldt Rasmussen U, Leenhardt L, Luster M, Schalin-Jäntti C, Schott M, et al: Thyroglobulin measurement using highly sensitive assays in patients with differentiated thyroid cancer: A clinical position paper. Eur J Endocrinol 171: R33-R46, 2014. 16. Remonti LR, Kramer CK, Leitão CB, Pinto LC and Gross JL: Thyroid ultrasound features and risk of carcinoma: A systematic review and meta-analysis of observational studies. Thyroid 25: 538-550, 2015. 17. Doherty JR, Trahey GE, Nightingale KR and Palmeri ML: Acoustic radiation force elasticity imaging in diagnostic ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control 60: 685-701, 2013. 18. Andrioli M and Persani L: Elastographic techniques of thyroid gland: Current status. Endocrine 46: 455-461, 2014. This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) License.