TESTING TITANIUM IMPLANTS

Similar documents
STUDIES AND RESEARCHES ON THE OBTAINING OF CAST TITANIUM IMPLANTS

Individual oncological implants

Case study for quality control & quality assurance in metal additive manufacturing: A dental bridge

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

Medical Device VSP Design & Manufacturing. Virtual Surgical Planning

SICHERHEITSDATENBLATT

QUALITY CONTROL OF DENTAL BRIDGES AND REMOVABLE PROSTHESES MANUFACTURED USING PHENIX SYSTEMS EQUIPMENT

Hip Joint Prostheses

YY Translated English of Chinese Standard: YY

A self-tapping internal hex. implant by MAKE IT SIMPLE

Orthopaedic. solutions

OT EQUATOR CASTABLE Single Attachment for Overdentures

INTRAMEDULLARY NAILING TIBIA AND FEMUR 1.3 TIBIAL AND FEMORAL NAILING FEMORAL NAILING WITH RETROGRADE INSERTION IMPLANTS AND OPERATING MANUAL

BONE SUBSTITUTION SPECIAL MEMBRANES SCREWS RIVETS

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

The fundamental biomechanics of oral implants. Dr. Szűcs Attila

4766 Research Dr. San Antonio, TX insightdentalsystems.com

NARROW DIAMETER implant

Arthrodesis System 2.0/2.3, 2.5

Torsion Property and Cyclic Fatigue Fracture Behavior of. Nickel-Titanium Endodontic Instruments

R-Group Finland Oy. RLS Lifting Sockets Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

Revision Modular Stem type RMD

Trefoil Procedure manual

NobelActive. The NobelActive technical story

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

DHS Plate 135º. DHS Platte 135º

EXTERNAL FIXATION SYSTEM

Formation of optimal surface of dental implants by CST SLA Process

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

Locator retained mandibular complete prosthesis (isy Implant System)

Revision systems. Catalogue - revision implants ARTHROPLASTY

Martin Bullemer Key Account Manager Medical 2008 April 16th

Laser Assembled and CAD/CAM Prosthetic Frameworks for the Debilitated Mandible. Robert Schneider, DDS, MS

High-end solution STEP-BY-STEP USER GUIDE

B&B DENTAL. implant company

A U X I L I A R Y C O N N E C T O R S Surgical Technique

GUIDED SURGERY TECHNIQUE

Dental and Surgical Applications of Selective Laser Melting

US Implant System 2013 PROSTHETIC PROCEDURE

Post-traumatic recovery mechanism on the ankle articulation

Immediate loading in heavy smokers

CHECK-UP Determination of Impression type & Method after implant placement

- RESTORATIVE PRODUCT CATALOG

A unique pocket design preventing slugs as the drill exits the component. This allows stacked plates and welded assemblies to be drilled.

Exploring the Effect of Pore Size and Distribution on Shear Strength of Surface Porous Polyetheretherkeytone (PEEK)

ADDITIVE MANUFACTURING AND ANALYSIS OF TIBIAL INSERT IN TOTAL KNEE REPLACEMENT IMPLANT

RBM dental implants by CST Process Technical Release September 2012

STRESS ANALYSIS OF DENTAL IMPLANT INSERTED IN THE MANDIBLE

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

Cementless femoral stem type SF

SIMULATOR FOR TESTING THE FRICTION TORQUE OF THE FEMORAL HEAD OF A HIP PROSTHESIS

Mini implants for Stabilization of partial dentures

PROXIMAL TIBIAL PLATE

N E W S M I L E S E V E R Y D AY

ASTM Committee F04 Tuesday 11/13/2012

INTERNATIONAL STANDARD

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Orthodontic Screw System

Ref: Q400-09T1 EBI Spine. September 05/VS02. c/o BIOMET Spain Orthopaedics, S.L.

Inlay Fixed Partial Denture Framework 3-D Structural Integrity Validation Using COMSOL Multiphysics 3.5a

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

CERTIFICATE OF ACCREDITATION

FATIGUE DEVICE FOR TESTING ANKLE JOINT ENDOPROSTHESES

C O M PA N Y P R O F I L E S I N C E W E H AV E B E E N H E L P I N G D E N T I S T S T O M A K E T H E I R PAT I E N T S S M I L E

ISO INTERNATIONAL STANDARD. Dentistry Implants Dynamic fatigue test for endosseous dental implants

Pediatric LCP Hip Plate. For osteotomy and trauma applications in the proximal femur.

STIFFENING PLATES FOR CERVICAL COLUMN

Designing a Novel Fixation Device for Pediatric Orthopaedic Tibia Fractures

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

NEW NEW. An Extended Solution for Narrow Ridges

Pre-Operative Planning. Positioning of the Patient

operative technique Universal Application

Abstract. Keywords: Fatigue Failure, Surface Roughness, Fatigue Strength Factor, Bio-Compatible Dental Implant, Electron Beam Melting (EBM)

Innovative Präzision Made in Germany

The Most Reliable Spinal Solution

3.5 mm Locking Attachment Plate

Electron Beam Melting EBM

For the oral rehabilitation

A complete surgical kit for Premium and Shelta systems

CERTIFICATE OF ACCREDITATION

NEW. An Extended Solution. for Narrow Ridges

External Skeletal Fixation (ESF)

A complete surgical kit for Premium and Shelta systems

You design, we create.

Identify the role of the skeletal system particularly in relation to maintaining an upright stance and protecting vital organs.

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

WINSTA-C. Clavicle Plating System

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Micro-CT imaging of surgical screw tightening in human trabecular bone

THE APPLICATIONS OF ERGONOMICS PRINCIPLES IN DESIGN-SPECIALS MATERIALS FOR DENTAL PRACTICE

TSLP Thoracolumbar Spine Locking Plate

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

The intelligent system.

NEW. An Extended Solution. for Narrow Ridges

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

In-process Inspection (MTC Project Review)

Transcription:

Proceedings in Manufacturing Systems, Volume 8, Issue 4, 3 ISSN 67-938 TESTING TITANIUM IMPLANTS Sorin Mihai CROITORU,*, Adrian Ion PACIOGA ) Assoc. Prof., PhD, Machines and Manufacturing Systems Dept., University Politehnica of Bucharest, Romania ) Senior Researcher, National Institute for Research and Development in Mechatronics and Measurement Technique of Bucharest, Romania Abstract: Dental and orthopaedic implants are supposed to be tested from medical and/or engineering points of view. This paper presents some engineering experimental research the authors made, related to titanium implants produced by the Romanian manufacturer of dental implants, Tehnomed Impex Co S.A. and the National Institute for Research and Development in Mechatronics and Measurement Technique of Bucharest (orthopaedic implants). Part of the experimental research was performed in the framework of a research contract financed by Romanian Ministry of Research and Education. The tests related to torsion resistance after chemical treatment of the implant were performed in order to see if the implant has the same (or at least enough) resistance even if its wall thickness is diminished after chemical treatment and its surface s micro geometry is modified. In this case the implants have enough resistance compared to the non treated implants, but the micro geometry has lower quality because of the chemical attack. Tests related to the crystallographic structure of the implant s material compared the methods of obtaining the implant: rolled bar and rapid prototyping laser sintered bar. In this case the rapid prototyping laser sintered implant has a more compact crystallographic structure, but the cost is greater. Key words: titanium implant, torsion, crystallographic structure, rolled bar, rapid prototyping.. INTRODUCTION This paper presents the research on implants made by the Romanian manufacturer, Tehnomed Impex Co S.A. and the National Institute for Research and Development in Mechatronics and Measurement Technique. The research subjects were imposed by special chemical treatment of the implant surface or manufacture method. In case the surface of the implant is chemically treated a thickness diminish of the implant s wall is involved due to the chemical reaction. This thickness diminish could be as much as.6. mm. Dental implants made by Tehnomed Impex Co S.A. have small wall thickness, less than.5 mm, between the inner threaded hole, used for fixing the superior structure and external thread used for fixing into the jaw bone (Fig. ). During the insertion into the bone, the implant has to be screwed, thus implant torsion is involved. The following question appeared: will the implant cease to torsion during the insertion because the smaller wall thickness due to the chemical treatment? The answer to this question is given by the torsion test of the implants, both chemically treated or not. Another question appeared because of the new titanium implants manufacturing method which is rapid prototyping. This method is used by the National Institute for Research and Development in Mechatronics and Measurement Technique of Bucha manufacture * Corresponding author: 33 Spl. Independenţei, Sector 6, 64 Bucharest, Romania, Tel.: +44974; mobile: +4763858; Fax: +4494. E-mail addresses: sorin.croitoru@gmail.com (S.M. Croitoru); pacioga@yahoo.com (A. Pacioga) +, L p D M,5 +,4 +, Fig.. Dental implant (Tehnomed). personalized orthopaedic implants. Because the material, in this case titanium, is layered point to point is the resulted material porous? In order to answer this question two samples of titanium, one sample of rolled bar and one sample obtained by rapid prototyping, were studied related to their crystallographic structure. Both research subjects lead to interesting conclusions, but it should be mentioned the implants were very good in all cases, having enough strength to be used instead the bones they were supposed to replace. The only threats, other than medical ones were the imposed micro geometry and cost.

4 S.M. Croitoru and A.I. Pacioga / Proceedings in Manufacturing Systems, Vol. 8, Iss. 4, 3 / 39 44. TORSION TESTS OF DENTAL IMPLANTS.. Preliminary research data In the framework of a research project two series of dental implants prototypes φ4x mm were chemically processed. The difference between these two series was the implants material, respectively pure titanium, grade IV and alloyed titanium TiAl6V4. Manufacturing and mechanical testing were done by Tehnomed Impex Co S.A. and POLITEHNICA University of Bucharest, Cutting and Cutting Tools Lab. of Machines and Manufacturing Systems Dept. Chemical processing of the dental implants was done by METAV-CD S.A. In order to characterize the dental implants shape after the chemical processing, there were done measurements at the Cutting and Cutting Tools Lab. of Machines and Manufacturing Systems Dept. Measurements were done on the workshop microscope RK-3, having the accuracy of. mm (Fig. ). Evidently, measurements were done before and after the chemical processing. Without giving the measurements results, some observations could be presented in the following. In case of dental implants made of pure titanium, grade IV: head of the implant is no longer cylinder, but a barrel; generally, the dimensions diminish after chemical processing by. mm, in average, with a minimum of.8 mm and a maximum of.85 mm for different dimensions; chemical reaction is not uniform, leading to the shape modification of the implant; in one case, a chemical deposition was observed; comparing the sanded implants to the sanded and chemically processed implants a pregnant alveolar structure is observed in the first case. In the second case, the alveolar structure is lower, even disappeared in some areas. In case of dental implants made of alloyed titanium TiAl6V4: one implant presents depositions; diminish of the dimensions is.7 mm minimum and.44 mm maximum; chemical reaction is not uniform, however the implant head looks more like a cylinder than a barrel, compared to the pure titanium implants; the last observation related to the sanded surface is the same as in case of dental implants made of pure titanium. Because diminish of the dimensions of the chemically processed implants the question of implants smaller resistance appeared. This is why some torsion tests of the implants were done, in order to their crack. It should be mentioned that in addition to the chemically processed implants there were manufactured another 3 implants made of pure titanium and another implants made of alloyed titanium. They were used as reference in torsion tests of the chemically processed implants. a b Fig. 3. KISTLER dynamometer: a measuring element and non-contact receptor; b CPU and PC with specialized software Dynoware. Fig.. Workshop microscope RK-3. Fig. 4. Prototype implants, KISTLER dynamometer measuring element and used tools for insertion.

S.M. Croitoru and A.I. Pacioga / Proceedings in Manufacturing Systems, Vol. 8, Iss. 4, 3 / 39 44 4 Fig. 5. Prototype implants, used tools and bone for insertion. Measurement of the torsion moment was done in the Cutting Tools Lab. using a KISTLER dynamometer with the sensible element used for measuring drilling cutting forces: axial force and torsion moment. The dynamometer is presented in Fig. 3,a and b. Tested implants and some of the used tools for insertion (tubular wrench and implant adaptor) are presented in figure 4. Considering that the real danger for dental implant cracking occurs during its insertion into the bone, the following insertion was designed: the dental implant is inserted into a pig bone, by its torsion using a hexagonal adaptor, the negative hexagon of the dental implant. The adaptor is driven by means of a tubular wrench, which is fixed into the collet of the KISTLER measuring element (see Fig. 3,a tubular wrench fixed into the collet and Fig. 5 set of tubular wrench). In fact, the pig bone was driven (rotated) while the rest of the elements were fixed. The KISTLER measuring element sensed the torsion moment during this insertion operation. In respect to ASTM F67-6, chemical composition of pure titanium and tensile resistance are presented in Table, for each grade. From Table it is revealed that with increase of the alloy elements percentage the tensile resistance increases. The same trend exists in case of alloyed titanium, tensile resistance reaching even MPa. This means, practically, the tensile resistance of the alloyed titanium is twice the tensile resistance of the pure titanium... Experimental results The experiments objective was to reach the torsion moment for cracking chemically processed dental implants, in order to compare them to not chemically processed dental implants. In the following, the succession of the experiments will be presented, together with the graphs of the torsion moment measured with KISTLER dynamometer. It should be mentioned from the beginning the dynamometer has its own adjustments, the measured values being the real ones. However, some tests were made to verify the dynamometer functioning, for reasons that will be presented in the following. First test was done by screwing the first reference dental implant made of pure titanium into a pig bone, in which were made holes of 3 mm diameter, unthreaded (see Fig. 5). The aim was to self threading the implant followed by its blocking and, eventually, cracking. It should be mentioned that in the real case the implant is screwed into a threaded hole. Torsion moment is presented in Fig. 6. It was concluded that the torsion moment does not increase above.34 Nm because the adaptor deformed losing its hexagonal shape. It could be possible that the hexagonal shape of the adaptor was not accurate from the beginning (the adaptor could be used). Consequently, another new hexagon shape was cut; the experiment was remade obtaining the situation in Fig. 7. Again, the hexagonal shape of the adaptor deformed. Because the adaptor was made of alloyed titanium, it was considered that if the adaptor will be made of carbon steel for cutting tools it will resist. So, with the new adaptor made of carbon steel for cutting tools the measurement was the one presented in Fig. 8 In this last test the hexagonal adaptor deformed again. Furthermore, the pig bone cracked between the initial hole and its end. This shows, if necessary, the insertion must be done in a threaded hole made in the bone. In these circumstances, the tests done on the reference dental implant made of pure titanium was abandoned. Table Chemical composition of pure titanium grades (ASTM F67-6) in mass percentage and tensile resistance Alloy Grade Grade Grade 3 Grade 4 Element Nitrogen,.3.3.5.5 Carbon,.8.8.8.8 Hydrogen,.5.5.5.5 Iron,..3.3.5 Oxygen,.8.5.35.4 Titanium, % % % % % R m, MPa 4 345 45 55,6,4,,8,6,4, Reference pure titanium, test 5 5 5 3 35 -, Fig. 6. Experimental torque, -st not treated implant, test.

4 S.M. Croitoru and A.I. Pacioga / Proceedings in Manufacturing Systems, Vol. 8, Iss. 4, 3 / 39 44 Reference pure titanium, test Reference pure titanium, test 3,5E+,E+,5E+,E+ 5,E-,E+ 5 5 5 3 35-5,E-,4,35,3,5,,5,,5 -,5 5 5 5 3 35 -, -,5 Fig. 7. Experimental torque, -st not treated implant, test. Fig.. Experimental torque, -nd not treated implant, test 3. Reference pure titanium, test 3 Reference pure titanium, test 4,5,5,5,5,5,5 5 5 5 3 35 5 5 5 3 35 -,5 -,5 Fig. 8. Experimental torque, -st not treated implant, test 3. Fig.. Experimental torque, -nd not treated implant, test 4. Reference pure titanium, test,e+ 8,E- 6,E- 4,E-,E-,E+ 5 5 5 3 35 -,E- -4,E- Fig. 9. Experimental torque, -nd not treated implant, test. Reference pure titanium, test,5e+,e+,5e+,e+ 5,E-,E+ 5 5 5 3 35-5,E- Fig.. Experimental torque, -nd not treated implant, test. In case of the second reference dental implant made of pure titanium, the tests were done using an aluminium bar instead of the pig bone for blocking the implant and crack it. Furthermore, two adaptors made of C hardened steel for molds were manufactured. In order to avoid the possibility to deform the hexagonal surfaces of the dental implant and the adaptor, another external cylinder to cover both cylindrical head of the dental implant and cylindrical head of the adaptor was manufactured. Before making the measurements during the torsion test of the implant a test to verify the measurement range of the dynamometer was done (Fig. 9). The aim was to verify the possibility to measure a torsion moment for cracking the dental implants, estimated to be 6- Nm. Consequently, the insertion of second reference dental implant made of pure titanium was made into a hole made in an aluminium bar, with the adaptor made of C hardened steel and external cylinder. It can be observed there were done 7 twists and torsion moment did not have values above.9 Nm. Hexagonal surface of the adaptor cracked partially, breaking in the next experiment, presented in Fig.. Of course, the adaptor was changed and the tests continued. The second adaptor made of C hardened steel resisted, but the aluminium bar ceased (Fig. ). The implant was twisted by means of a gripper, the dental implant thread being destroyed, but even in these conditions the torsion moment did not exceed 3. Nm (Fig. 3).

S.M. Croitoru and A.I. Pacioga / Proceedings in Manufacturing Systems, Vol. 8, Iss. 4, 3 / 39 44 43 Reference pure titanium, test 5 3,5 3,5,5,5 5 5 5 3 35 tim e, sec Fig. 3. Experimental torque, -nd not treated implant, test 5. Fig. 5. Crystallographic structure of TiAl6V4 rolled bar (8 ). Sample pure titanium, chemically processed 3,5 3,5,5,5 5 5 5 3 35 -,5 tim e, sec Fig. 4. Experimental torque, treated implant. Only for information, a single experiment was done for the first dental implant made of pure titanium chemically processed, in the conditions of the previous experiment (Fig. 3), obtaining the graph in Fig. 4. The result was strictly similar. The torsion moment value never reached 6 Nm..3. Conclusions of the tests After all these experiments the following conclusions can be stated:. In practice there is no possibility to force dental implants in the presented experimental conditions.. Breaking of the pure titanium dental implant occurs at last, after the deterioration of the inserting tools and/or the bone in which the insertion is made. 3. Deterioration of the bone is out of question, because the insertion is done in a threaded hole. 4. Because the resistance of the alloyed titanium is double compared to that of the pure titanium, there is no problem of the resistance of the implants made of alloyed titanium. At last, it is considered that the resistance of the titanium dental implant is so great that it is not influenced by diminish of the dimensions due to the chemical processing nor by the superficial layer resulted. 3. CRISTALLOGRAPHY TESTS OF TITANIUM IMPLANTS There are different manufacturing methods of the titanium implants: cutting from rolled bars, forming, and rapid prototyping. Fig. 6. Crystallographic structure of TiAl6V4 laser sintered rapid prototyping sample (8 ). The presented following tests were done in order to see if newly appeared rapid prototyping personalized titanium implants have more porous structure than those manufactured from rolled bars. This question was motivated by the very rapid prototyping technology, which deposits material point by point, every point being melted and welded to the rest of material. The National Institute for Research and Development in Mechatronics and Measurement Technique has new equipment for rapid prototyping laser sintering of titanium powder. This is the reason it is interested in manufacturing personalized implants using this technology. In order to compare the two materials proposed, rolled bar and rapid prototyping sample, the authors made the tests of crystallographic structure at University Politehnica of Bucharest, Faculty of Materials Engineering. Figure 5 presents the microstructure of a rolled bar made of TiAl6V4. This material is used by Romanian manufacturer of dental implants and other implantable devices, Tehnomed Impex Co S.A. In comparison, Fig. 6 presents the microstructure of a sample of TiAl6V4 obtained by laser sintered rapid prototyping. It can be seen the directions of laser depositions layer after layer.

44 S.M. Croitoru and A.I. Pacioga / Proceedings in Manufacturing Systems, Vol. 8, Iss. 4, 3 / 39 44 Even if the initial aim of these tests was to see how porous the micro structure of the samples is, there are also other things to be seen. It can be observed there are more pores in the rolled bar micro structure than in rapid prototyping structure. This could be explained by characteristics of the two technologies: rolling and rapid prototyping. Of course, rapid prototyping obtains finer structures than rolling because of point after point deposition, which leads to a more uniform structure. It is very interesting to see the micro crystals in Fig. 5 and not seeing them in Fig. 6. Rapid prototyping technology involves layers deposition along different directions layer after layer, which leads to a reinforcement of micro structure. It could be interesting to make tensile tests of the two types of material structures, to see the difference. This is a future research direction. 4. CONCLUSIONS This paper presents engineering tests on titanium implants of two different types:. Dental implants made either of pure titanium, grade IV or alloyed titanium TiAl6V4, manufactured by Romanian producer of dental implants and other medical implantable devices, Tehnomed Impex Co S.A. Bucharest. These implants were manufactured by cutting operations and chemically processed in the end.. Orthopaedic implants made of alloyed titanium TiAl6V4, manufactured by the National Institute for Research and Development in Mechatronics and Measurement Technique of Bucharest. These implants were manufactured by laser sintered rapid prototyping. All tests were done in POLITEHNICA University of Bucharest, in the laboratories of Machines and Manufacturing Systems Dept. and in the Faculty of Materials Science. For tests regarding torsion moment of the dental implants made of pure and alloyed titanium, the following conclusions can be presented:. Tests were done in order to obtain the capable torsion moment of the implants, chemically processed or not. This meant the authors wanted to crack the implant and see the value of the torsion moment. The question to be answered was if the chemically processed implants have less resistance than the not processed ones. The possible reasons of a smaller resistance could be the thinner wall of the chemically processed implant and the chemically modified surface of the implant.. Because resistance of the alloyed titanium is twice the resistance of the pure titanium, it was not necessary to test implants made of TiAl6V4, because implants made of pure titanium had enough resistance; 3. The experimental conditions were much harder than in the real case, experimentally trying to screw the implants into unthreaded holes made into pig hard bone or aluminium. Even in these conditions the authors did not crack the pure titanium dental implant, both chemically processed or not. Furthermore, the inserting tools ceased, even if they were made of hardened steel for molds (usually, they are made of alloyed titanium). Finally, the conclusion is that the resistance of the titanium dental implant, either pure or alloyed, is so great that it is not influenced by diminish of the dimensions due to the chemical processing nor by the superficial layer resulted. Tests regarding the microstructure of the different possible methods to obtain the material implant were made with the aim to see how porous is the material, considering that pores are stress concentrators. The two considered methods to obtain the implant s material were rolling in case the implant is manufactured by cutting or laser sintering rapid prototyping. Two important conclusions revealed:. There are more pores in rolled bar used as raw material for dental implants made by cutting than in the implants made by laser sintering rapid prototyping. This could be explained by the difference between the two technologies, rapid prototyping obtaining finer micro structure.. Micrograph of the implant made by laser sintering rapid prototyping revealed a reinforced micro structure of the material, with strings along different directions for each layer, as this method deposits point by point. This could mean the tensile resistance of the implant could be greater than the resistance of the rolled bars of titanium. ACKNOWLEDGEMENT: Part of the work presented in this paper was supported by Romanian Ministry of Research and Education in the framework of the Program Research of Excellence, contract No. 7-57/8.9.7. REFERENCES [] S.M. Croitoru, D. Oprea, Experimental Research on Measuring Cutting Efforts During Aluminium Alloys Drilling, Proceedings of the 6-th International Conference on Manufacturing Systems ICMaS 7, Published by Editura Academiei Române, ISSN 84-383, Bucharest, Romania, pp. 53-56. [] C. Minciu, S.M Croitoru, Experimental research on cutting efforts at zinc alloys drilling and milling, Academic Journal of Manufacturing Engineering, ISSN 583-794, 9, Sibiu, Romania. [3] A.I. Pacioga, Cercetări privind dezvoltarea unei noi baze conceptuale în designul şi fabricarea protezelor de şold prin personalizarea lor (Research on the development of a new conceptual base in the design and manufacture of hip prosthesis through customization), PhD Thesis, University Politehnica of Bucharest,. [4] * * * ASTM F67 Standard Specification for Unalloyed Titanium, for Surgical Implant Applications; [5] * * * SR ISO 583-/996 Implanturi chirurgicale. Produse metalice. Partea :Titan nealiat (Implants for surgery. Metallic materials. Part : Unalloyed titanium) IDT ISO 583-3:993. [6] * * * SR ISO 583-3/996 Implanturi chirurgicale. Produse metalice. Partea 3: Aliaj deformabil titan-aluminiu 6- vanadiu 4 (Implants for surgery. Metallic materials. Part 3: Wrought titanium 6-aluminium 4-vanadium alloy), IDT ISO 583-3:99.