Optimum implant geometry

Similar documents
Optimum implant geometry

Featuring. Technology. Product Rationale

Bone Preservation Stem

Optimum implant geometry

PINNACLE REVISION CUP SYSTEM

Approach Patients with Confidence

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

Design Rationale. ECHELON Primary Hip System

AML Hip System. Design Rationale/ Surgical Technique

FLH /11

Approach Patients with Confidence

Fixed and Variable Geometry Total Shoulder Arthroplasty

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Arcos Modular Femoral Revision System

Understanding Hip Implant Options

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Approach Patients with CONFIDENCE

Reaching new heights. Comprehensive. Efficient. Simple.

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

Product Rationale. Where Strength and Modularity Connect

Specifications guide ECHELON. Hip System

RECLAIM REVISION HIP SYSTEM

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Optimizing function Maximizing survivorship Accelerating recovery

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

28 Surgical Technique

This publication is not intended for distribution in the USA.

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Surgical Technique. Hip System

Bone Bangalore

One system for all revision types

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Tri-Lock Bone Preservation Stem

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Metha Short Hip Stem System

Preoperative Planning. The primary objectives of preoperative planning are to:

PROFEMUR Total Hip System P R O D U C T C A T A L O G

ReCap Product Rationale

S U R G I C A L T E C H N I Q U E

Revision. Hip Stem. Surgical Protocol

PLR. Proximal Loading Revision Hip System

HIP SYSTEM SURGICAL TECHNIQUE

The Leader in Orthopaedic Innovation

LPS SYSTEM POCKET GUIDE

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

G7 ACETABULAR SYSTEM. beautifully. efficient.

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

Bone Conserving Hip Replacement Surgical technique

INSTRUMENTS. Design Rationale

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Continuing the Tradition. VerSys Heritage Hip System

D E S I G N R A T I O N A L E

HP Knee Extraction Instrumentation. Product Overview

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

MetaFix. Cementless Total Hip Replacement Surgical technique

Restoration Modular Revision Hip System. Choice Matters

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

Clinical Evaluation Surgical Technique

TOTAL HIP REPLACEMENT:

Cementless femoral stem type SF

CERAMIC-ON-METAL. References: Cat No: version 2

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

9800 Metric Blvd. Austin, Texas

Ovation Hip System. Surgical Technique

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

CORAIL HIP SYSTEM DESIGN RATIONALE

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

The science of simplicity

INSTRUMENTS. Product Rationale

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

ANATOMIC LOCKED PLATING SYSTEM

Zimmer Segmental System

SUMMIT and DURALOC. Clinical Summary

Tissue Sparing. DEsign Rationale

ACETABULAR CUP SURGICAL TECHNIQUE

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Exeter. Technical Guide

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

SURGICAL TECHNIQUE. Entrada Hip Stem

simplicity THE SCIENCE OF DESIGN RATIONALE

HP KNEE EXTRACTION Instrumentation. Product Overview

Absolut TM Cemented Stem. Surgical Technique

Peggers Super Summaries: THR and Revision Concepts

The proven, simple solution. CPT 12/14 Hip System

Integral 180 Surgical Technique

Aesculap Trilliance Triple Tapered Polished Hip Stem

Revision Modular Stem type RMD

Scan Bi-Polar 22/28. Operative Technique

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Design Rationale/Surgical Technique GRIPTION TF

Progeny Hip Stem. Surgical Protocol and Product Specifications

Transcription:

Design Rationale

Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available to orthopaedic surgeons and their patients. Since its introduction, Tri-Lock has demonstrated 98% survivorship. 1 Preserving the natural anatomy The reduced lateral shoulder, thin geometry and optimized length of the Tri-Lock Bone Preservation Stem minimize the amount of bone removed from the patient. These same features, along with approach enabling instrumentation, allow the surgeon to perform minimally invasive techniques. Delivering stable, predictable performance The Tri-Lock Bone Preservation Stem incorporates Gription fixation technology. Gription is designed to help provide consistent implant seating height and additional initial stability that helps maximize the potential for long-term bony ingrowth. Restoring high level function The Tri-Lock Bone Preservation Stem neck geometry has been optimized to improve range-of-motion. Progressive dual offsets with direct lateralization provide the ability to optimize soft tissue tension. An extensive size range and consistent intervals between sizes help achieve proper fit and aid in recreating leg length. Providing advanced bearing options The Tri-Lock Bone Preservation Stem s 12/14 Articul/eze taper enables the use of the most advanced bearing options available today. The Pinnacle Acetabular Cup System gives the surgeon a choice of bearing materials, and the option for screw fixation. The DePuy ASR XL metal-on-metal system maximizes head-to-shell ratio, providing an exceptional range-of-motion and outstanding hip stability. Enabling a simple, reproducible technique Today s total hip surgeon demands proven performance, OR efficiency, and surgical approach flexibility. The new Tri-Lock Bone Preservation Stem delivers on all fronts. The broach-only technique and wide range of instrumentation enable both traditional and less-invasive surgical approaches. 1

Extending proven Tri-Lock heritage Survivorship at 10 years. 1 The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered wedge hip stem available to orthopaedic surgeons and their patients. Since its introduction, the success of Tri-Lock has been well documented in published studies. Using component revision for aseptic loosening as the end point, the numbers are convincing. 2

Axial stability The Tri-Lock Bone Preservation Stem achieves axial stability within the femur by making intimate cortical contact at the medial and lateral endosteal cortices. The natural taper of the femoral canal is reflected in Tri-Lock s proximal-to-distal taper, as viewed in an A/P radiograph. This taper prohibits distal migration when cortical contact is achieved. Rotational stability The inherent rotational stability of the Tri-Lock Bone Preservation Stem is a result of the narrow anterior-to-posterior width of the stem. This narrow geometry allows the stem to be sized to fill the largest dimension of the femoral canal (the medial-to-lateral width). Since the M/L width of the implant is larger than the A/P width of the femoral canal, the Tri-Lock Bone Preservation Stem maintains excellent rotational stability. Long-term osteointegration The initial axial and rotational stability of the Tri-Lock Bone Preservation Stem provide the opportunity for long-term osteointegration. Initial stability limits micromotion at the implant to cortical bone interface, resulting in a higher probability for bony ingrowth. 3

Preserving the natural anatomy Soft tissue preservation Bone preservation Optimized length, contoured distal tip and reduced lateral shoulder enhance stem insertion through the anterior and antero-lateral approaches Broach only technique enables minimally invasive surgical approaches where access with straight reamers is limited Instrumentation designed to enable the surgeons preferred approach Reduced lateral shoulder enables the preservation of the greater trochanter Thin anterior-to-posterior width requires minimal cancellous bone removal Optimized length preserves distal canal Reduced distal medial-to-lateral width provides proper proximal fit and preserves distal cortical bone in Dorr Type A femora 5 High 50-degree neck cut preserves calcar bone and increases proximal support

Delivering stable, predictable performance Gription s predicted 1.2 coefficient of friction exceeds that of plasma spray and porous tantalum material. 2 The volume porosity of Gription reaches 63% at the surface. This increased porosity allows for higher oxygenation and revascularization of bony tissue. Gription provides a clinically advantageous 300-micron average pore size. This pore size has been proven optimal for osteointegration. 3 Gription is highly microtextured. This microtexture provides an increased surface area for osteoblast cells to adhere and proliferate. The Tri-Lock Bone Preservation Stem and Gription coating are composed of titanium, a material with proven biocompatibility and a low modulus of elasticity. The Tri-Lock Bone Preservation Stem incorporates Gription fixation technology. Gription is an evolutionary advancement in implant coating technology. This advanced coating technology builds upon DePuy s 30-year tradition of cementless implant excellence. The critical coating properties that Porocoat has proven effective for long-term survivorship have been replicated in Gription. Advanced technology has allowed DePuy to optimize Gription s properties, providing consistent implant seating height, exceptional initial stability and a maximized potential for long-term osteointegration. 6

7

159 Optimized neck geometry The Tri-Lock Bone Preservation Stem neck geometry is optimized to improve range of motion and maximize hip stability. 159 range of motion can be achieved when coupled with the Pinnacle Acetabular Cup System. 8

Restoring high level function Progressive dual offset Stem offset is proportional to stem size. Each stem size offers a standard and high offset option. The high offset option lateralizes the stem 6 8 mm depending on size. By maintaining a constant 130 neck angle, tissue tension can be increased without affecting leg length. Extensive size range The Tri-Lock Bone Preservation Stem system features 13 stem sizes, allowing the surgeon to address the larger patient population. Consistent intervals between each stem size help achieve proper fit within the femur. Component sizing can also be used to fine tune seating height and adjust leg length. 9

Providing advanced bearing options Pinnacle with Marathon. Marathon polyethylene combines mechanical integrity with wear resistance. This moderately cross-linked (5 Mrad) polyethylene is manufactured to have zero oxidative potential. Pinnacle with AltrX. This moderately cross-linked polyethylene (7.5 megarads) demonstrates mechanical toughness and zero oxidative potential, while providing a 92 percent reduction in wear. 2 Pinnacle with Ultamet. Ultamet metal-on-metal bearings are designed and manufactured to reduce wear and increase stability, while offering modularity and adjunct fixation. Made with highly polished, high-carbon cobalt chrome, Ultamet bearings have optimized diametrical clearance and sphericity to provide true fluid film lubrication and low wear. 10

DePuy ASR XL. As a monoblock metal-on-metal system, ASR XL provides the largest head size possible for a given acetabulum. Large head metal-on-metal articulation improves hip stability and enhances fluid film lubrication. The Tri-Lock Bone Preservation Stem 12/14 Articul/eze taper enables the use of the most advanced bearing options available today. The Pinnacle Acetabular Cup System gives the surgeon choice in bearing materials. The DePuy ASR XL metal-onmetal system maximizes head-to-shell ratio, providing an exceptional range of motion and outstanding hip stability. 11

Enabling a simple, reproducible technique Step 1: Neck osteotomy Step 2: Femoral canal preparation Step 3: Femoral component insertion 12

Straight Straight-long Curved Dual-offset Approach enabling broach handle options Threaded Straight modular Curved modular Offset modular Bullet-tip modular Approach enabling stem inserter options 13

References: 1. Burt CF et al. A Femoral Component Inserted without Cement in Total Hip Arthroplasty. A Study of the Tri-Lock Component with an Average Ten Year Duration of Follow-up. JBJS 1998 Jul 80(7) 952-60. 2. Data on file at DePuy 3. Bolyn, et al. The Optimum Pore Size for the Fixation of Porous Surfaced Metal Implants by the Ingrowth of Bone. CORR, 150, 1980. DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46581-0988 USA Tel: +1 (800) 366 8143 Fax: +1 (574) 371 4865 DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0)113 387 7800 Fax: +44 (0)113 387 7890 2.0M0508 0612-88-506 Printed in USA. DePuy Orthopaedics, Inc. 2008.All rights reserved.