Emissions and Hearing Thresholds After a Six-Month Deployment on an Aircraft Carrier

Similar documents
Low-level otoacoustic emissions may predict susceptibility to noise-induced hearing loss a)

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

A longitudinal study of changes in evoked otoacoustic emissions and pure-tone thresholds as measured in a hearing conservation program

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

FALSE POSITIVE DP GRAMS

NSMRL TECHNICAL REPORT #TR1231 February 26, 2004

Optimizing DPOAEs for Serial Monitoring: From Nitty-gritty Solutions to Source Separation

Optimizing DPOAEs for Serial Monitoring: From Nitty-gritty Solutions to Source Separation

Clare Forshaw Corporate Medical Unit, Health & Safety Executive. Bootle

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

(Otoacoustic Emissions and Automated ABR)

Annelies Bockstael, Hannah Keppler, and Dick Botteldooren

functional, toxicological, and pharmacological similarities between inner ear cells and cells of the kidney tubules.

Introduction. IAPA: June 04 1

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

Utility of Standard DPOAEs in the Evaluation of the Normal-Hearing Tinnitus Patient

Neuro-Audio Version 2010

OtoAcoustic Emissions (OAE s)

TEMPORARY HEARING THRESHOLD SHIFT MEASURED BY OTOACOUSTIC EMISSIONS IN SUBJECTS EXPOSED TO SHORT-TERM IMPULSE NOISE

Hearing protectors and the possibility to detect noise-induced hearing damage using otoacoustic emissions in situ.

Hearing Evaluation: Diagnostic Approach

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

Proposed Recommended Procedure for the Use of OAEs in Hearing Conservation: a Delphi Exercise

Proceedings of Meetings on Acoustics

Auditory Tests for the Early Detection of Noise-Susceptible Individuals A Literature Study

Abstract. 1 Introduction

Protocol for Fast, Efficient Audiogram Prediction using Electrophysiology. Sponsored By

Selected Publications on middle ear pressure and otoacoustic emission testing (Pressurized OAEs)

Advanced otoacoustic emission detection techniques and clinical diagnostics applications

Effects of flight on auditory function in pilots

Comparison of Distortion Product Otoacoustic Emission Amplitude between Normal Hearing Male and Female Subjects

Physiological basis of sound design. Prof. Dr. med. Eckhard Hoffmann Dipl.-Ing. (FH) Steffen Kreikemeier Aalen University of Applied Sciences

Terri-Lynn Gagnon M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

Effects of Exam Procedures on Transient Evoked Otoacoustic Emissions (TEOAEs) in Neonates

Otoacoustic emissions in detection of pre-clinical noise induced cochlear damage in military personnel

Trajectory of the Aging Cochlea

Significance of a notch in the otoacoustic emission stimulus spectrum.

TITLE: The Use of Drugs to Reduce Hearing Loss Following Acute Acoustic Trama

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

Hidden Hearing Loss? Effects of Recreational Noise on Evoked Potential Amplitude and Other Auditory Test Metrics

Synaptopathy Research Uwe Andreas Hermann

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

A Review of the Effectiveness of Otoacoustic Emissions for Evaluating Hearing Status After Newborn Screening

3M Center for Hearing Conservation

More robust estimates for DPOAE level at audiometric frequencies

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Changes in Transient-Evoked Otoacoustic Emission Levels with Negative Tympanometric Peak Pressure in Infants and Toddlers

Hearing assessment is an essential part of hearing conservation.

Otoacoustic Emissions

Role of Distortion Product Otoacoustic Emissions (DPOAES) In Detecting Early Hearing Impairment in Individuals With Normal Pure Tone Audiometry (PTA)

THE ROLE OF PHARMACEUTICAL AGENTS IN HEARING LOSS MANAGEMENT AND PREVENTION

Hearing Conservation Program

Difference Evaluation Method for Differential Diagnosis of Frequency Specific Hearing Loss

Distortion product otoacoustic emissions as a health surveillance technique for hearing screening in workers in the steel manufacturing industry

The clinical Link. Distortion Product Otoacoustic Emission

ORIGINAL ARTICLE. High-Frequency Hearing Influences Lower-Frequency Distortion-Product Otoacoustic Emissions

March-April 2014 Volume 16 Issue 69 ISSN Impact Factor for 2012: 1.648

S ound is a form of energy generated by vibration. It can be

Detection of middle ear dysfunction using wideband acoustic tests in newborn hearing screening and diagnostic follow-up

Reliable, flexible & precise

Medical Surveillance for Hearing Loss

Audiological Diagnosis after Newborn Screening

NOISE INDUCED HEARING LOSS AND AUDIOMETRY

Hearing Impairment in Pre-eclampsia

A Mixed-Methods Assessment of Hearing Conservation Program Effectiveness

ERO SCAN. Otoacoustic Emission Testing

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

A Guide to. Otoacoustic Emissions (OAEs) for Physicians.

The Need for New Measurements on Aircraft Carriers. By Gary A. Morris, Justin Bryant, Kim Kleine and Amanda Dean

Hearing Conservation Compendium Report CY2015. Navy and Marine Corps Public Health Center Occupational Audiology and Hearing Conservation Division

A pilot study of changes in otoacoustic emissions after exposure to live music

A Guide to. Otoacoustic Emissions (OAEs) for Otolaryngologists.

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

A Comparison of Baseline Hearing Thresholds Between Pilots and Non-Pilots and the Effects of Engine Noise

HEARING CONSERVATION PROGRAM

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

Hearing Conservation Terminology Courtesy of Workplace Integra, Inc.

Health Standards to Protect Miners from Hearing Loss

Six Components of Hearing Conservation Program. Helene R. Freed, Ed.M Public Relations Specialist Industrial Hearing Testing

Swept - Tone Evoked Otoacoustic Emissions: Stimulus Calibration and Equalization

What s New? Example 2 Employee B. Example 1 - Employee A

Jacob Sulkers M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

Auditory Weighting Functions and Frequency-Dependent Effects of Sound in Bottlenose Dolphins (Tursiops truncatus)

Handheld OAE-Tympanometry Combination System

ACOUSTIC INFRASOUND AND LOW-FREQUENCY SOUND

D-methionine (D-met) as a Protective Agent. Kathleen Campbell, PhD Professor & Director of Audiology Research SIU School of Medicine

INDH 5131 Controls of Occupational Hazards. Noise & Hearing Conservation. Part II. V. Audiometric Testing

Workplace Noise Surveys: A Hands-On Measurement Workshop

Hearing Screening, Diagnostics and Intervention

NOISE CONTROL AND HEARING CONSERVATION PROGRAM

Supplement. Karl R. White National Center for Hearing Assessment and Management, Utah State University, Logan

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

Transcription:

#772 Changes in Evoked Otoacoustic Emissions and Hearing Thresholds After a Six-Month Deployment on an Aircraft Carrier Lynne Marshall, Judi A. Lapsley Miller, Laurie M. Heller, Linda M. Hughes, and Linda J. Westhusin Naval Submarine Medical Research Laboratory USS Dwight D. Eisenhower Hearing Conservation Team ARO - 30 Jan 2002 1

Abstract Evoked otoacoustic emissions and hearing thresholds were measured in 339 sailors from the USS Dwight D. Eisenhower aircraft carrier before and after a six-month deployment to the Mediterranean. Sailors from the Air, Reactor, and Engineering departments were targeted because they were considered most at risk for noiseinduced hearing loss. At pre-deployment and post-deployment testing, hearing thresholds (0.5 to 6 khz) were measured using a modified Hughson-Westlake procedure and normal middle-ear pressure was established. Transient-evoked otoacoustic emissions (non-linear click stimulus at 74 db pspl) and distortionproduct otoacoustic emissions (f2/f1=1.22, at four stimulus levels) were then measured using the Otodynamics ILO292 Echoport. There was no consistent change in average hearing thresholds for the group; however, some individuals showed significant threshold shifts. Temporary threshold shifts were confirmed for two sailors (two ears) and permanent threshold shifts were confirmed for fifteen sailors (eighteen ears), based on their noise history and a confirmatory audiogram. Some additional significant threshold shifts were unable to be confirmed. Preliminary group results indicated that after deployment there was a decrease in average distortion-product and transient-evoked otoacoustic-emission amplitudes. Changes in otoacoustic-emission amplitudes might be a more sensitive indicator of noise-induced damage to the inner ear than changes in hearing thresholds. ARO - 30 Jan 2002 2

Are evoked otoacoustic emissions more sensitive than the audiogram to the effects of noise on the ear? Our approach is to study hearing and otoacoustic emissions before and after hazardous noise exposures in ears that are at risk for noise-induced hearing loss The crew of the aircraft carrier USS Dwight D. Eisenhower (CVN69) are such a population Overview ARO - 30 Jan 2002 3

Further Information Contact Details Lynne Marshall NSMRL, Box 900 Subase NLON Groton CT 06349-5900 phone 860-694-2550 email marshall@nsmrl.navy.mil Acknowledgements Thanks to the crew of CVN 69, the tireless NSMRL data collectors, the Occupational Health Dept/Audiology Dept. at Norfolk Naval Hospital, and the Naval Environmental Health Center. The views expressed in this article are those of the authors and do not reflect the official policy or position of the Department of the Navy, Department of Defense, or the United States Government. This research was supported by the Office of Naval Research. ARO - 30 Jan 2002 4

Method Subjects 339 sailors measured 3 months before and immediately after a 6-month deployment 29 controls subjects measured twice without intervening noise exposure (usually the same day) Measurements Noise history Audiogram (0.5-6kHz) Middle-ear pressure TEOAEs non-linear 74 db pspl, analyzed into 1/2 octave bands DPOAEs L1/L2= 65/45, 61/55, 59/50, and 57/45 db SPL, f2/f1=1.22, f2=1.8, 2.0, 2.5, 2.8, 3.2, 3.6, and 4.0 khz* * 2.2 and 4.5 khz dropped from all analyses due to electrical interference contaminating measurements ARO - 30 Jan 2002 5

Noise Exposure Aircraft carriers are noisy! Exposure durations often exceed 8 hours per day Few quiet areas for recovery Some areas require double hearing protection Airborne Noise just below Flight Deck Courtesy of Kurt Yankaskas Flight Deck filled with planes Needle-guns, grinders, chippers, etc. Nuclear power plant Some sleeping compartments directly below flight deck ARO - 30 Jan 2002 6

Changes in Hearing Individuals Significant threshold shifts 15 sailors (18 ears) had permanent threshold shifts 2 sailors (2 ears) had temporary threshold shifts 21 sailors (25 ears) had unconfirmed significant threshold shifts These shifts could not be categorized further into permanent or temporary shifts because a follow-up audiogram was not possible ARO - 30 Jan 2002 7

Subjects used for Group Analyses Group analyses used 75 subjects from noisy areas Air (Flight Deck) n=34 Engineering n=12 Nuclear Propulsion n=29 All subjects for these analyses had TEOAEs and DPOAEs* at 2, 2.8, and 4 khz at both pre and post-test** Vulnerable subjects may not be included because of requirement for measurable emissions *If the post-test EOAE was below the noise floor and the noise floor was lower than the pre-test EOAE then the noise floor was substituted for the EOAE. This underestimates the true difference. ** DPOAE level 61/55 was not included due to too many unexplained outliers ARO - 30 Jan 2002 8

No Change in Group Hearing A three-way repeated-measures ANOVA (pre-/post-test, ear, frequency) indicated that group average hearing thresholds did not change after noise exposure Significant main effect for ear and frequency (p<0.05) Interactions for test-by-frequency and test-by-ear-by-frequency The interactions do not show changes consistent with NIHL ARO - 30 Jan 2002 9

Fig 1: No Change in Group Hearing Hearing Threshold (db HL) -10 0 10 20 30 Pre-test Left Post-test Left Pre-test Right Post-test Right 0.5 1 2 3 4 6 Frequency (khz) Fig 1. Group average hearing thresholds show no (main effect) change between pre and post test, for each ear (n=150) ARO - 30 Jan 2002 10 10

TEOAEs & DPOAEs Decreased A three-way repeated-measures ANOVA (pre-/post-test, ear, frequency) indicated that the group average TEOAE amplitude decreased after noise exposure (see Fig. 2) Significant main effects for test, ear, and frequency (p<0.05) Significant interaction effects for test-by-frequency and ear-by-frequency Biggest decrease at 4 khz A four-way repeated-measures ANOVA (pre-/post-test, ear, DP level, and frequency) indicated that the group average DPOAE amplitude decreased after noise exposure (see Fig. 3) Significant main effects for test, level, and frequency (p<0.05), but not ear Significant interaction effects for test-by-level, ear-by-level, and level-by-frequency Biggest decreases at lower levels ARO - 30 Jan 2002 11

Fig 2: TEOAEs Decreased TEOAE Amplitude (db SPL) 4 3 2 1 0-1 Pre-test Left Post-test Left Pre-test Right Post-test Right 2 2.8 4 Frequency (khz) Fig 2. Group average TEOAE amplitude decreased between pre and post test, for each ear (n=150) ARO - 30 Jan 2002 12 12

Fig 3: DPOAEs decreased DPOAE Amplitude (db SPL) 10 8 6 4 2 0-2 Pre-test 65/45 Post-test 65/45 Pre-test 59/50 Post-test 59/50 Pre-test 57/45 Post-test 57/45 2 2.8 4 Frequency (khz) Fig 3. For each level, group average DPOAE amplitude decreased between pre and post test, averaged over ears (n=150) ARO - 30 Jan 2002 13 13

Hearing & OAE Shift Agreement No correlation between changes in hearing and changes in TEOAEs or DPOAEs (r<0.3) Each individual ear (n=150) classified for presence of a significant decrement in hearing and/or a significant decrement in emission amplitude A significant shift is greater than three times the standard error of measurement of control group Only weak agreement between hearing and emission decrement categories For both TEOAEs and DPOAEs, emission-shift category was not a good predictor of hearing-shift category Hearing Shift Yes No ARO - 30 Jan 2002 14 TEOAE Shift DPOAE Shift Yes No Yes No 3 29 7 111 Hearing Shift Yes No 4 40 6 100 14

TEOAE & DPOAE Shift Agreement Changes in TEOAEs and DPOAEs were correlated (0.3<r<0.6) Each individual ear (n=150) classified for presence of significant TEOAE and/or DPOAE shifts at 2, 2.8, and 4kHz A significant shift is greater than three times the standard error of measurement of control group Any shift (decrements and increments) and decrements-only considered separately There is moderate agreement between the two types of emission shift. TEOAE Any Shift TEOAE Decrements Yes No Yes No DPOAE Any Shift Yes No 33 13 24 80 DPOAE Decrements Yes No 23 6 19 102 ARO - 30 Jan 2002 15

Summary Otoacoustic emissions are more sensitive to the early stages of inner-ear changes related to excessive noise exposure (after noise exposure, group average TEOAE and DPOAE amplitudes both decreased, but group average hearing levels did not worsen) More individuals had significant changes in emission level than significant changes in hearing Changes in OAEs do not agree with changes in hearing Changes in TEOAEs and DPOAEs are somewhat consistent Future analyses will examine characteristics of significant emission shifts in individuals and susceptibility to noiseinduced hearing loss ARO - 30 Jan 2002 16