Practical Aspects of Standardisation for a Global Controls Manufacturer

Size: px
Start display at page:

Download "Practical Aspects of Standardisation for a Global Controls Manufacturer"

Transcription

1 Practical Aspects of Standardisation for a Global Controls Manufacturer MRSA SoGAT Clinical Diagnostic Meeting NIBSC, UK June 25, 2008 Frank Opdam PhD, AcroMetrix

2 Standardisation A fundamental goal of laboratory medicine is that results for patients samples will be comparable independent of the medical laboratory that produced the results.* *W. Greg Miller et al Clinical Chemistry. 2006;52:

3 CMV monitoring in Canada A practical example of difficulties caused by a lack of standardisation

4 Probability of CMV Disease Probability of acquiring CMV disease with increasing viral load (renal patients) CMV Load (Log 10 copies/ml) *Aitken et al. J. Clin. Micro : 2804.

5 Cytomegalovirus Quantification Agreement plot for 100 plasma samples with detectable viral loads by the Abbott and Monitor tests. Dotted line, mean difference for the samples; dashed lines, 95% limits of agreement. The clinical utility of CMV viral load testing is well established and is considered the standard of care in monitoring the response to antiviral therapy. However, the lack of standardization among CMV viral load assays continues to be problematic for clinical laboratories.* *A.M. Caliendo et al. J Clin Microbiol Jun; 45(6): Emory University School of Medicine, Atlanta

6 CMV CAP Survey College of American Pathologists (CAP) proficiency testing results shows majority of participating labs rely on laboratory developed quantitative CMV tests 2006 ID A survey

7 Cut-off values associated with active disease vary by specific assay type Though these tests have proven to be very useful for individual laboratories, it has been difficult to establish broadly applicable, clinically relevant guidelines for the use of laboratorydeveloped CMV viral load assays. * *Debra G.B. Leonard, Molecular Pathology in Clinical Practice (2007), Chapter 38 p. 427 Viral Infections in Transplant Patients by Andrea Ferreira-Gonzalez and Angela M. Caliendo

8 CMV in Canada Example of a problem Province A 1e5cp/ml Transplantation Patient moves to Province B Provincial Labs are aware of these differences and educate physicians accordingly Province B 1e4 cp/ml

9 CMV copies Result is 8000 CMV cp/ml for a Solid Organ Donor Transplantation What should the physician do? Depends on assay: Roche AMPLICOR CMV Intervention Point: 5000 cp/ml Qiagen Artus ASR* CMV Intervention Point: cp/ml * Analyte Specific Reagents

10 QCMD CMV proficiency programme Detection of clinical important viral load levels as low as 1000 copies/ml are not yet optimal and laboratories should aim for improvement October 2007 (CMVDNA07) final report

11 CMV Conclusion Lack of defined units and calibration material results in difficult to establish broadly applicable, clinically relevant guidelines

12 Assayed Control Material Roche: cp/ml, log 4.01 Abbott: cp/ml log 4.37 Qiagen: 9570 cp/ml log: 3.98 Hypothetical Example created with Adobe Photoshop

13 Assayed Weight

14 NAT Calibration Paradox Instrument often trusted more than Control Different results for same sample on different systems considered normal

15 Is an assayed control acceptable?

16 Metrology The Science of Measurement Establishes measurement units Develops new measurement methods Provides measurement standards Traceability from standards to users Ensures suitability of measurement instruments Calibration and quality control of measurements

17 Cornerstones of Metrology Standardization Metrology Calibration Traceability (Value +/- uncertainty)

18 How to Calibrate a Scale Certified Calibrator used to check instrument Same calibrator can be used for different scales Calibrator has more credibility than instrument

19 Questions not asked How much does the 10 g calibration weight weigh on my scale? Do I get the same result on my new digital scale and my old balance?

20 Why does our industry sometimes ask? Which is correct value of the 1e5 IU/mL standard on my analyzer? Do I get with your material the same result on the system from company A versus the system from company B?

21 Inconsistent Results Non-Standardised Calibration Standard 1 System Company A PC1 Standard 2 System Company: B PC2 Standard 3 System Company: C PC3 Standard 4 System Company: D PC4 Current scenario for all analytes (e.g. CMV) except HIV-1, HBV and HCV

22 Limitations of Current NAT Control Materials (assayed, unassayed and kit controls) Not metrological based Often based on specific assay system Units not clearly defined Not independent (assayed & kit controls) Not useful for Standardisation

23 Consistent Results Standardised Calibration Instrument: A Traceable Calibrator or Standard Instrument: B Instrument: C Instrument: D Scenario for established measurement systems (e.g. scale)

24 Metrological Levels high low Level Traceable to SI Unit Int. reference measurement method See ISO 17511:2003 Introduction p. vii Calibrator Material Example 1 a) Yes Yes Yes Electrolytes 2 b) 1 No Yes Yes HbA 1c 3 b) 2 No Yes No 4 b) 3 No No Yes Haemostatic factors WHO Standard 5 b) 4 No No No MRSA

25 AcroMetrix Control Development AcroMetrix Quality System ISO 13485:2003 certified FDA 21CFR Part 820 Quality System Regulations (QSR) cgmp Calibrators and Controls values assigned following ISO 17511:2003 In vitro diagnostic medical devices Measurement of quantities in biological samples Metrological traceability of values assigned to calibrators and control materials

26 ISO17511: Traceability Traceability allows assay independent value assignment

27 Old School Measurement and Calibration Calibration of a Scale Certified Test Weights = Standards Traceable International Prototype Kilogram (IPK)

28 Example MRSA Development of a novel independent run control, compliant with ISO 17511

29 Hospital acquired drugresistant microorganisms Among patients with a secondary Staphylococcal infection diagnosis- those who had isolates tested for antimicrobial susceptibility had 52% lower probability of death before discharge, 17% lower mean length of stay (-2 days), and 22% lower cost than those who did not The majority (~50%) of infections is identified as methicillinresistant Staphylococcus aureus (MRSA) F. R. Lichtenberg: The value of Diagnostics: The Impact of Hospital Antimicrobial Susceptibility Testing. Prepared for The Advanced Medical Technology Association. March 2008

30 MRSA testing 1. Allows the physicians to administer appropriate and effective treatments 2. Reduces quarantine time/cost No international MRSA standard available, so how to: 1. Assess sensitivity? 2. Monitor day to day performance? 3. Control for extraction, amplification and detection

31 Metrological Level: 5 Requires In-house measurement procedure In-house calibrator Generate in-house unit according ISO 17511:2003 clause d Level Traceable to SI Unit Int. reference measurement method Calibrator Material Example 1 a) Yes Yes Yes Electrolytes 2 b) 1 No Yes Yes HbA 1c 3 b) 2 No Yes No 4 b) 3 No No Yes Haemostatic factors WHO Standard 5 b) 4 No No No MRSA

32 Challenges for Development of a Control for MRSA Which strain should be used? Can we use whole bacteria? Which matrix to use? What is correct level for control?

33 Characteristics for a reliable MRSA control 1) quantified levels of bacterial cells 2) a low level of cells to interrogate the performance of the assay on a daily basis 3) close similarity to a patient sample 4) stable 5) high reproducibility (minimal vial-to-vial variability) 6) Preferably non infectious

34 MRSA strain for in-house working calibrator Hospital acquired Type: SCCmec Type 1 Strain: A (Juuti) Non infectious Bacteria are inactivated in-house working calibrator unit: CFU/mL

35 MRSA strain for in-house working calibrator (2) From H.G. Schlegel, Allgemeine Mikrobiologie, 1985, 6. überarbeitete Auflage Strain: A (Juuti): a phenotype demonstrating reduced aggregation (grape-shape formation) and increased consistency by Real-Time PCR compared to current Staphylococcus aureus strains used as external controls.

36 Quantification of an inactivated MRSA control From the viable MRSA stock the number of colonies grown on agar plates was determined (CFU/mL) The Ct value was determined for a low positive control on the Gene Xpert the amount of inactivated MRSA was determined to reach this Ct value. This amount was assigned to the value from the viable stock

37 Quantification through Ct values # bacteria CFU Ct correct shifted earlier

38 Cycle trheshold (Ct) Quantification through Ct values *E3 5*E MRSA MSSA

39 Mean Titer (CFU/ml) MRSA reproducibility OptiQual ATCC 43300

40 Mean Ct value OptiQual MRSA Positive Control stability Accelerated Stability Tested with Cepheid GeneXpert 35,0 32,5 30,0 27,5 25,0 22,5 20, Time (weeks) OptiQual MRSA 45C OptiQual MRSA 37C OptiQual MRSA 25C According to the Arrhenius equation at least one year of stability at 2-8 C

41 Mean Ct Value OptiQual MRSA inter-laboratory performance Site Testing using Cepheid Gene Xpert 35,0 32,5 30,0 27,5 25,0 22,5 20,0 AcroMetrix (n = 8*) Scott and White Hospital (n = 8) Kingman Regional Medical Center (n = 4)

42 Conclusions OptiQual MRSA controls demonstrate superior precision Vs ATCC, enabling laboratories to monitor true assay variability. OptiQual MRSA control contains whole bacteria to monitor entire procedure to meet laboratory quality control requirements. Because of ISO17511 compliance, AcroMetrix is capable of rapidly developing different control levels, if required.

43 The Shape of Things to come?

Results of the College of American Pathologists (CAP) Proficiency Program for CMV, EBV, and BKV Viral Load Testing

Results of the College of American Pathologists (CAP) Proficiency Program for CMV, EBV, and BKV Viral Load Testing 2009 College of American Pathologists. The College does not permit reproduction of any substantial portion of the material in this Report without its written authorization. The College hereby authorizes

More information

Development of a NIST Standard Reference Material for Cytomegalovirus

Development of a NIST Standard Reference Material for Cytomegalovirus Development of a NIST Standard Reference Material for Cytomegalovirus Marcia Holden, Ross Haynes, Margaret Kline, John Butler (with help from David Duewer (NIST) and Steve Ellison (LGC)) Group, Biochemical

More information

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2017Oct27

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2017Oct27 1 The National Laboratory for HIV Reference Services is Accredited to ISO 15189 and ISO 17043 National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology

More information

INTERNATIONAL WORKING GROUP ON THE STANDARDISATION OF GENOME AMPLIFICATION TECHNIQUES (SoGAT) FOR CLINICAL DIAGNOSTICS

INTERNATIONAL WORKING GROUP ON THE STANDARDISATION OF GENOME AMPLIFICATION TECHNIQUES (SoGAT) FOR CLINICAL DIAGNOSTICS INTERNATIONAL WORKING GROUP ON THE STANDARDISATION OF GENOME AMPLIFICATION TECHNIQUES (SoGAT) FOR CLINICAL DIAGNOSTICS SoGAT Clinical Diagnostics I, 24-25 June 2008 National Institute for Biological Standards

More information

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2018Oct26

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2018Oct26 1 National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory Public Health Agency of Canada HIV Viral Load Quality Assessment Program Summary

More information

Experience with Standardisation of Blood Virology NAT. Clare Morris Division of Retrovirology National Institute for Biological Standards and Control

Experience with Standardisation of Blood Virology NAT. Clare Morris Division of Retrovirology National Institute for Biological Standards and Control Experience with Standardisation of Blood Virology NAT Clare Morris Division of Retrovirology National Institute for Biological Standards and Control Background of Blood Virology Standardisation In the

More information

CMV DNA Quantification Using an Automated Platform for Nucleic Acid Extraction and Real- time PCR Assay Set-up

CMV DNA Quantification Using an Automated Platform for Nucleic Acid Extraction and Real- time PCR Assay Set-up JCM Accepts, published online ahead of print on 11 May 2011 J. Clin. Microbiol. doi:10.1128/jcm.00721-11 Copyright 2011, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights

More information

The use of QCMD proficiency testing panels in clinical virology.

The use of QCMD proficiency testing panels in clinical virology. The use of QCMD proficiency testing panels in clinical virology. Prof.dr. Bert Niesters Department of Medical Microbiology Division of Clinical Virology UMC Groningen Disease Disease Management Viral Load

More information

Quantification of HBV, HCV genotype and HIV subtype panels

Quantification of HBV, HCV genotype and HIV subtype panels Quantification of HBV, HCV genotype and HIV subtype panels Harry van Drimmelen 1,2, Wim Quint 2, Nico Lelie 3 and the international NAT study group 1. Biologicals Quality Control, 2. DDL Diagnostic Laboratory,

More information

CALIBRATION OF ANALYTICAL STANDARDS FOR HBV-DNA, HCV-RNA AND HIV-1 RNA IN GENOME COPIES BY A REFERENCE METHOD

CALIBRATION OF ANALYTICAL STANDARDS FOR HBV-DNA, HCV-RNA AND HIV-1 RNA IN GENOME COPIES BY A REFERENCE METHOD CALIBRATION OF ANALYTICAL STANDARDS FOR HBV-DNA, HCV-RNA AND HIV-1 RNA IN GENOME COPIES BY A REFERENCE METHOD AAJ van Drimmelen, E.R. Bax and W.G.V. Quint, BioQControl (BQC), Delft Diagnostic Laboratories

More information

External Quality Assessment Programmes (EQAPs) for blood-borne viruses: the Italian experience

External Quality Assessment Programmes (EQAPs) for blood-borne viruses: the Italian experience External Quality Assessment Programmes (EQAPs) for blood-borne viruses: the Italian experience Giulio Pisani Biologicals Unit CRIVIB, ISS, Rome SOGAT XXII 14 th 15 th April 2011 - Istituto Superiore di

More information

Use of Viral Load Testing in Managing CMV Infections in SOTR

Use of Viral Load Testing in Managing CMV Infections in SOTR Use of Viral Load Testing in Managing CMV Infections in SOTR Angela M. Caliendo, MD, PhD, FIDSA Professor and Vice Chair, Medicine Alpert Medical School of Brown University Providence, RI Disclosures Scientific

More information

Fifteen years of molecular EQA: progress and challenges

Fifteen years of molecular EQA: progress and challenges Fifteen years of molecular EQA: progress and challenges Anton M van Loon 1, Stuart West 2 and Paul Wallace 2 1 Department of Virology, UMC Utrecht, The Netherlands 2 QCMD, Glasgow, Scotland Key Issues

More information

Standardization: Calibration of. International Standards, reference preparations and working standards. Micha Nübling, PEI

Standardization: Calibration of. International Standards, reference preparations and working standards. Micha Nübling, PEI Standardization: Calibration of International Standards, reference preparations and working standards Micha Nübling, PEI Paul-Ehrlich-Institut Governmental Authority for biological medicinal products Blood

More information

INTRODUCTION PRODUCT DESCRIPTION

INTRODUCTION PRODUCT DESCRIPTION INTRODUCTION Mycoplasma are known as important contaminants of biological products derived from cell lines in the biopharmaceutical industry affecting every parameter of a cell culture system. Contaminated

More information

Introduction: Table/Figure Descriptions:

Introduction: Table/Figure Descriptions: Introduction: We have completed the analysis of your HIV RNA Validation Study. The validation plan was designed to verify the installation of an unmodified FDA-approved HIV RNA assay into your laboratory.

More information

Received 19 April 2011/Returned for modification 6 June 2011/Accepted 13 June 2011

Received 19 April 2011/Returned for modification 6 June 2011/Accepted 13 June 2011 JOURNAL OF CLINICAL MICROBIOLOGY, Aug. 2011, p. 2899 2904 Vol. 49, No. 8 0095-1137/11/$12.00 doi:10.1128/jcm.00785-11 Copyright 2011, American Society for Microbiology. All Rights Reserved. Comparative

More information

Biological Consulting Services

Biological Consulting Services Biological Consulting Services of North Florida/ Inc. May 13, 2009 Aphex BioCleanse Systems, Inc. Dear Sirs, We have completed antimicrobial efficacy study on the supplied Multi-Purpose Solution. The testing

More information

CMV Diagnostic Strategies: Current and Future

CMV Diagnostic Strategies: Current and Future CMV Diagnostic Strategies: Current and Future Tony Mazzulli, MD, FRCPC, FACP Microbiologist-in-Chief Mount Sinai Hospital & University Health Network, Toronto Faculty/Presenter Disclosure Relationships

More information

DEVELOPMENT OF AN INTERNATIONAL REFERENCE PREPARATION FOR HEPATITIS D VIRUS RNA - UPDATE

DEVELOPMENT OF AN INTERNATIONAL REFERENCE PREPARATION FOR HEPATITIS D VIRUS RNA - UPDATE DEVELOPMENT OF AN INTERNATIONAL REFERENCE PREPARATION FOR HEPATITIS D VIRUS RNA - UPDATE SoGAT Clinical Diagnostics III 12-13 January 2011, London Michael Chudy Julia Kreß Micha Nübling Paul-Ehrlich-Institut

More information

Understanding Quality Control for Infectious Disease Testing. Wayne Dimech ASLM Quality Control Workshop Abuja, Nigeria 9 th December 2018

Understanding Quality Control for Infectious Disease Testing. Wayne Dimech ASLM Quality Control Workshop Abuja, Nigeria 9 th December 2018 Understanding Quality Control for Infectious Disease Testing Wayne Dimech ASLM Quality Control Workshop Abuja, Nigeria 9 th December 2018 Disclosure Attendance at ASLM part-sponsored by CDC No personal

More information

QUALITY CONTROL for MOLECULAR DIAGNOSTICS Quality issues highlighted through international external quality assessment

QUALITY CONTROL for MOLECULAR DIAGNOSTICS Quality issues highlighted through international external quality assessment QUALITY CONTROL for MOLECULAR DIAGNOSTICS Quality issues highlighted through international external quality assessment William G MacKay PhD Neutral Office Coordinator QCMD The Altum Building, Todd Campus

More information

for Microbiology Quality Assessment Programmes for HPV and MRSA Effect of change to assessment categories for HBV DNA Dr Vivienne James SoGAT 2009

for Microbiology Quality Assessment Programmes for HPV and MRSA Effect of change to assessment categories for HBV DNA Dr Vivienne James SoGAT 2009 for Microbiology Quality Assessment Programmes for HPV and MRSA Effect of change to assessment categories for HBV DNA Dr Vivienne James Overview Update on the HPV scheme introduced in 2009 MRSA screening

More information

John Saldanha Regulatory Requirements: Precision and Accuracy of Quantitative NAT Tests XXII SoGAT Meeting, April, 2011

John Saldanha Regulatory Requirements: Precision and Accuracy of Quantitative NAT Tests XXII SoGAT Meeting, April, 2011 John Saldanha Regulatory Requirements: Precision and Accuracy of Quantitative NAT Tests XXII SoGAT Meeting, 14 15 April, 2011 Istituto Superiore di Sanita (ISS), Rome, Italy 2 June 2011 page 1 2011 Roche

More information

New proposals for WHO International Standards for Human Herpesvirus 6 and Adenovirus

New proposals for WHO International Standards for Human Herpesvirus 6 and Adenovirus New proposals for WHO International Standards for Human Herpesvirus 6 and Adenovirus Jacqueline Fryer Division of Virology, NIBSC National Institute for Biological Standards and Control Assuring the quality

More information

Innovations in nucleic acid amplification technologies. Automated platforms for NAT. Microfluidics Digital PCR Innovations in nucleic acid microarrays

Innovations in nucleic acid amplification technologies. Automated platforms for NAT. Microfluidics Digital PCR Innovations in nucleic acid microarrays About the author Disclaimer EXECUTIVE SUMMARY Molecular diagnostic technologies Healthcare-associated infections Sexually transmitted HPVs HIV and hepatitis viruses Market outlook and forecasts Molecular

More information

Trends in molecular diagnostics

Trends in molecular diagnostics Trends in molecular diagnostics Detection of target genes of interest Quantification Infectious diseases HIV Hepatitis C & B TB / MAC Cytomegalovirus Herpes simplex Varicella zoster CT/GC HPV Profiling

More information

Jefferies Healthcare Conference. John Bishop Chairman & CEO June 2, 2014

Jefferies Healthcare Conference. John Bishop Chairman & CEO June 2, 2014 Jefferies Healthcare Conference John Bishop Chairman & CEO June 2, 2014 1 Cepheid Cepheid Worldwide Market Growth by Segment Overall IVD sales are projected to grow at a 5.9% CAGR through 2017. Molecular

More information

Multilaboratory Evaluation of Real-Time PCR Tests for Hepatitis B Virus DNA Quantification

Multilaboratory Evaluation of Real-Time PCR Tests for Hepatitis B Virus DNA Quantification JOURNAL OF CLINICAL MICROBIOLOGY, Aug. 2011, p. 2854 2858 Vol. 49, No. 8 0095-1137/11/$12.00 doi:10.1128/jcm.00471-11 Copyright 2011, American Society for Microbiology. All Rights Reserved. Multilaboratory

More information

Update from ISS on following EQA studies: ISS EQA Tri-NAT (HCV, HIV and HBV) 2012 ISS EQA NAT HBV 2012 ISS EQA NAT WNV 2012

Update from ISS on following EQA studies: ISS EQA Tri-NAT (HCV, HIV and HBV) 2012 ISS EQA NAT HBV 2012 ISS EQA NAT WNV 2012 Update from ISS on following EQA studies: ISS EQA Tri-NAT (HCV, HIV and HBV) 2012 ISS EQA NAT HBV 2012 ISS EQA NAT WNV 2012 SOGAT XXIV Ljubljana, 8-9 May 2013 2012 ISS EQAs for NAT ISS EQA Tri-NAT (HCV,

More information

WHO Parvovirus B19 Genotype Panel

WHO Parvovirus B19 Genotype Panel WHO Parvovirus B19 Genotype Panel Mei-ying W Yu, PhD SoGAT XXII Rome, 14-15 April 2011 1 st WHO International Reference Panel for Parvovirus B19 Genotypes In Oct 2009, a plasma-derived parvovirus B19 (B19V)

More information

AMPLIRUN TOTAL A RELIABLE QUALITY CONTROL SOURCE FOR NUCLEIC ACID TESTS

AMPLIRUN TOTAL A RELIABLE QUALITY CONTROL SOURCE FOR NUCLEIC ACID TESTS AMPLIRUN TOTAL A RELIABLE QUALITY CONTROL SOURCE FOR NUCLEIC ACID TESTS Take Control, Molecular Control. 02 04 05 06 06 07 08 08 AMPLIRUN TOTAL RESPIRATORY INFECTIONS TUBERCULOSIS INFECTIONS GASTROINTESTINAL

More information

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS altona DIAGNOSTICS Instructions for Use RealStar CMV PCR Kit 1.2 08/2017 EN RealStar RealStar CMV PCR Kit 1.2 For research use only! (RUO) 021202 INS-021200-EN-S01 48 08 2017 altona Diagnostics GmbH Mörkenstr.

More information

Customer Service and Ordering Address Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands

Customer Service and Ordering Address Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands PRODUCT CATALOGUE Customer Service and Ordering Address Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands Communication +31 72 202 07 30 +31 72 202 07 31 sales@bioqcontrol.com

More information

Non-competitive Internal Control Concept for PCR-based Qualitative Assays

Non-competitive Internal Control Concept for PCR-based Qualitative Assays Christian O. Simon Roche Molecular Diagnostics Rotkreuz, CH Non-competitive Internal Control Concept for PCR-based Qualitative Assays 23 rd SoGAT Meeting, 16 th 17 th April, 2012, Vilnius, Lithuania Design

More information

VARIATION IN MEASUREMENT OF HIV RNA VIRAL LOAD

VARIATION IN MEASUREMENT OF HIV RNA VIRAL LOAD VARIATION IN MEASUREMENT OF HIV RNA VIRAL LOAD SOURCES OF VARIATION (RANDOM VS SYSTEMATIC) MAGNITUDE OF EACH SOURCE CONSEQUENCES FOR CONFIDENCE LIMITS AROUND MEASUREMENTS AND CHANGES DATA FROM ROCHE HIV

More information

Stability of native, lyophilized and inactivated standards

Stability of native, lyophilized and inactivated standards Stability of native, lyophilized and inactivated standards Harry van Drimmelen Bio Quality Control, Heiloo, Netherlands Satellite Meeting before IPFA-PEI 25 th Workshop Twenty-five Years Standardization

More information

Mathematical Microbiologists: Why we have to return to our square roots to uncover uncertainty (of measurement) in Quantitative PCR (qpcr)

Mathematical Microbiologists: Why we have to return to our square roots to uncover uncertainty (of measurement) in Quantitative PCR (qpcr) Mathematical Microbiologists: Why we have to return to our square roots to uncover uncertainty (of measurement) in Quantitative PCR (qpcr) J. Ian Stuart George Zahariadis Marina Salvadori Objectives 1.

More information

Instructions for Use (Version 3-14 th May 2003) Changes from previous version are shown in Red, deletions are shown as ^

Instructions for Use (Version 3-14 th May 2003) Changes from previous version are shown in Red, deletions are shown as ^ Page 1 of 5 Page 1 of 5, 97/656 WHO 1 st International Standard for HIV-1 RNA for Nucleic Acid-Based Techniques (NAT) NIBSC code: 97/656 Instructions for Use (Version 3-14 th May 2003) Changes from previous

More information

Proposed 1 st IS for Hepatitis E Virus RNA WHO/BS/

Proposed 1 st IS for Hepatitis E Virus RNA WHO/BS/ www.pei.de Proposed 1 st IS for Hepatitis E Virus RNA WHO/BS/09.2126 S. Baylis, Division of Virology, Paul-Ehrlich-Institut, Langen, Germany SoGAT XXII 14 th -15 th April 2011, Rome, Italy Presented at:

More information

Update on the. Clinical Diagnostics. and. Blood Testing. Meetings of SoGAT. Micha Nübling, PEI.

Update on the. Clinical Diagnostics. and. Blood Testing. Meetings of SoGAT. Micha Nübling, PEI. Update on the www.pei.de Clinical Diagnostics and Blood Testing Meetings of SoGAT Micha Nübling, PEI SoGAT Since 1995: 22 SoGAT meetings (organized by NIBSC) 1-2 meetings/year (connected with IPFA workshop)

More information

Molecular Diagnosis Future Directions

Molecular Diagnosis Future Directions Molecular Diagnosis Future Directions Philip Cunningham NSW State Reference Laboratory for HIV/AIDS & Molecular Diagnostic Medicine Laboratory, SydPath St Vincent s Hospital Sydney Update on Molecular

More information

Molecular diagnosis of infectious disease - Method validation and environmental setting 傳染病的分子診斷 - 方法確認與環境背景. WC Yam 任永昌

Molecular diagnosis of infectious disease - Method validation and environmental setting 傳染病的分子診斷 - 方法確認與環境背景. WC Yam 任永昌 Molecular diagnosis of infectious disease - Method validation and environmental setting 傳染病的分子診斷 - 方法確認與環境背景 WC Yam 任永昌 Dept of Microbiology Queen Mary Hospital The University of Hong Kong Clinical and

More information

Diagnostic Methods of HBV infection. Zohreh Sharifi,ph.D of Virology Research center, Iranian Blood Transfusion Organization (IBTO)

Diagnostic Methods of HBV infection. Zohreh Sharifi,ph.D of Virology Research center, Iranian Blood Transfusion Organization (IBTO) Diagnostic Methods of HBV infection Zohreh Sharifi,ph.D of Virology Research center, Iranian Blood Transfusion Organization (IBTO) Hepatitis B-laboratory diagnosis Detection of HBV infection involves

More information

Update on the development of clinical diagnostic run controls at NIBSC. Neil Almond Division of Virology

Update on the development of clinical diagnostic run controls at NIBSC. Neil Almond Division of Virology Update on the development of clinical diagnostic run controls at NIBSC Neil Almond Division of Virology BACKGROUND Molecular techniques are increasingly being used for microbiological diagnoses Assays

More information

EXPERT COMMITTEE ON BIOLOGICAL STANDARDIZATION Geneva, 18 to 22 October 2010

EXPERT COMMITTEE ON BIOLOGICAL STANDARDIZATION Geneva, 18 to 22 October 2010 ENGLISH ONLY EXPERT COMMITTEE ON BIOLOGICAL STANDARDIZATION Geneva, 18 to 22 October 2010 Collaborative Study to Evaluate the Proposed 1st WHO International Standard for Human Cytomegalovirus (HCMV) for

More information

Customer Service and Ordering Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands

Customer Service and Ordering Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands PRODUCT CATALOGUE Customer Service and Ordering Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands Communication +31 72 202 07 30 +31 72 202 07 31 info@bioqcontrol.com www.bioqcontrol.com

More information

Hepatitis C Virus (RNA)A

Hepatitis C Virus (RNA)A Hepatitis C Virus (RNA)A 2012 EQA Programme Final Report QAV994112 (HCVRNA12A) Professor Jacques Izopet Scientific Expert on behalf of QCMD Report authorised by the QCMD Executive in July 2012 A UKAS accredited

More information

The New Regulations - Special IVD Issues

The New Regulations - Special IVD Issues The New Regulations - Special IVD Issues Dirk Stynen, Ph. D. President - Principal Consultant Qarad Geel, Belgium RMD Brussels October 2018 The IVD Regulation 2017/746 October 29, 2018 www.qarad.com 2

More information

Official Journal of the European Communities COMMISSION

Official Journal of the European Communities COMMISSION 16.5.2002 EN Official Journal of the European Communities L 131/17 COMMISSION COMMISSION DECISION of 7 May 2002 on common technical specifications for in vitro-diagnostic medical devices (notified under

More information

NATIONAL MARROW DONOR PROGRAM. Creating Connections. Saving Lives. Fran Rabe

NATIONAL MARROW DONOR PROGRAM. Creating Connections. Saving Lives. Fran Rabe Creating Connections. Saving Lives. National Marrow Donor Program (NMDP) Screening of International Donors Fran Rabe FDA Liaison Meeting January 4, 2007 U.S. Importation of Peripheral Blood Stem Cells

More information

M. Khanna and S. Visuri

M. Khanna and S. Visuri The ProPneumo1 Assay: Detection of Chlamydophila pneumoniae, Mycoplasma pneumoniae, and an Internal Control Using Multiplex PCR on Multiple Real Time PCR Systems S. Dollhopf,, W. Majewski,, P. Douglass,

More information

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry.

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry. The design and development of a force comparator standard machine to provide national traceability in force measurement to industry. Speaker/ Author: S. Dlamini Co-author: C. Gouws National Metrology Institute

More information

Evaluation of the new Abbott mplus feature: Impact on clinical laboratory efficiencies with Abbott RealTime HIV-1, HCV, HBV and CT/NG assays

Evaluation of the new Abbott mplus feature: Impact on clinical laboratory efficiencies with Abbott RealTime HIV-1, HCV, HBV and CT/NG assays JCM Accepts, published online ahead of print on 2 October 2013 J. Clin. Microbiol. doi:10.1128/jcm.01672-13 Copyright 2013, American Society for Microbiology. All Rights Reserved. 1 2 3 4 5 Evaluation

More information

BEIPH Final Report. EQA Programme 2011 Chlamydia trachomatis (CTDNA11A) William G Mackay on behalf of QCMD and its Scientific Council April 2011

BEIPH Final Report. EQA Programme 2011 Chlamydia trachomatis (CTDNA11A) William G Mackay on behalf of QCMD and its Scientific Council April 2011 BEIPH Final Report EQA Programme 2011 Chlamydia trachomatis (CTDNA11A) William G Mackay on behalf of QCMD and its Scientific Council April 2011 Not to be reproduced or quoted without permission of QCMD.

More information

EC CERTIFICATE. National Institute for Biological Standards and Control (NIBSC) Blanche Lane South Mimms Potters Bar Hertfordshire EN6 3QG UK

EC CERTIFICATE. National Institute for Biological Standards and Control (NIBSC) Blanche Lane South Mimms Potters Bar Hertfordshire EN6 3QG UK National Institute for Biological Standards and Control (NIBSC) EC Certificate - Full Quality Assurance System Approval Certificate Annex IV (excluding sections 4 and 6) of Council Directive 98/79/EC on

More information

Xpert MTB/RIF Ultra: Understanding this new diagnostic and who will have access to it

Xpert MTB/RIF Ultra: Understanding this new diagnostic and who will have access to it Xpert MTB/RIF Ultra: Understanding this new diagnostic and who will have access to it Angela Starks, PhD Chief, Laboratory Branch Division of TB Elimination Matt Bankowski, PhD, MS, D(ABMM), HCLD/CC(ABB)

More information

RealLine HIV quantitative Str-Format

RealLine HIV quantitative Str-Format Instructions for use DETECTION AND QUANTIFICATION OF THE HUMAN IMMUNODEFICIENCY VIRUS RNA BY REAL TIME PCR Research Use Only (RUO) Attention! Please read the information about quantification process carefully!

More information

FEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION CLINICAL BIOLOGY SECTION

FEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION CLINICAL BIOLOGY SECTION IPH J. Wytsmanstreet 14 B-1050 Brussels FEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION CLINICAL BIOLOGY SECTION External Quality Assessment for Molecular

More information

Chlamydia trachomatis

Chlamydia trachomatis Chlamydia trachomatis 2012 EQA Programme A Final Report QAB004101 (CTDNA12A) Version 2 Dr Anton M van Loon Scientific Experts on behalf of QCMD Report authorised by the QCMD Executive in May 2012 A UKAS

More information

Infectious Disease Diagnostics

Infectious Disease Diagnostics Infectious Disease Diagnostics Tackling Infectious Diseases Uppsala Health Summit - October10 th, 2017 Stephan Jäger, Roche Diagnostics GmbH When to tackle infectious diseases Prevention & action contribution

More information

Impact of multi-dye multiplex technology on testing algorithm

Impact of multi-dye multiplex technology on testing algorithm Impact of multi-dye multiplex technology on testing algorithm Lydia Blanco. Mª Isabel Gonzalez-Fraile Centro de Hemoterapia y Hemodonación de Castilla y León, España TTI EPIDEMIOLOGICAL DATA IN SPAIN NAT

More information

VQA HIV DNA Control SOP Version 5.0 HIV DNA Testing 13 March 2012

VQA HIV DNA Control SOP Version 5.0 HIV DNA Testing 13 March 2012 1. PRINCIPLE 1.1. The Virology Quality Assurance (VQA) Laboratory provides external cell pellet controls for use in the validation of assays that detect HIV proviral DNA. 1.2. HIV seronegative peripheral

More information

Evaluation of run controls for cobas 6800 MPX and HEV assay

Evaluation of run controls for cobas 6800 MPX and HEV assay Evaluation of run controls for cobas 6800 MPX and HEV assay Marco Koppelman Head of Nucleic Acid testing (NAT) laboratory, National Screening laboratory of Sanquin (NSS) in the Netherlands Satellite Meeting

More information

artus EBV QS-RGQ Kit Performance Characteristics May 2012 Sample & Assay Technologies Analytical sensitivity plasma

artus EBV QS-RGQ Kit Performance Characteristics May 2012 Sample & Assay Technologies Analytical sensitivity plasma artus EBV QS-RGQ Kit Performance Characteristics artus EBV QS-RGQ Kit, Version 1, 4501363 Check availability of new electronic labeling revisions at www.qiagen.com/products/artusebvpcrkitce.aspx before

More information

Simpler QC for your Quality Systems. Thermo Scientific AcroMetrix Molecular Standards and Quality Controls. North American version

Simpler QC for your Quality Systems. Thermo Scientific AcroMetrix Molecular Standards and Quality Controls. North American version Simpler QC for your Quality Systems Thermo Scientific AcroMetrix Molecular Standards and Quality Controls North American version AcroMetrix Contents Introduction 4 Superior QC: AcroMetrix molecular quality

More information

Cepheid: Delivering a Better Way

Cepheid: Delivering a Better Way Cepheid: Delivering a Better Way Dieneke Brockmans March 14, 2017 1 Cepheid Our Mission Delivering a better way to improve patient outcomes by enabling access to molecular diagnostic testing everywhere.

More information

NEPHROCHECK Calibration Verification Kit Package Insert

NEPHROCHECK Calibration Verification Kit Package Insert NEPHROCHECK Calibration Verification Kit Package Insert Manufactured for Astute Medical, Inc. 3550 General Atomics Ct. Building 2 San Diego, CA 92121 USA Intended Use The NEPHROCHECK Calibration Verification

More information

B19 Virus EQA Programme Final Report QAV (B19DNA14)

B19 Virus EQA Programme Final Report QAV (B19DNA14) B19 Virus 2014 EQA Programme Final Report QAV034116 (B19DNA14) Prof. Hubert GM Niesters Scientific Expert on behalf of QCMD Report authorised by the QCMD Executive in July 2014 A UKAS accredited proficiency

More information

Cepheid The MDx Growth Leader. William Blair Growth Stock Conference June 12, 2012

Cepheid The MDx Growth Leader. William Blair Growth Stock Conference June 12, 2012 Cepheid The MDx Growth Leader William Blair Growth Stock Conference June 12, 2012 Forward Looking Statement During the course of this presentation, we may make projections or other forward looking statements

More information

New Generation of Nucleic Acid Testing. Michele Owen, Ph.D Division of HIV/AIDS Prevention Centers for Disease Control & Prevention

New Generation of Nucleic Acid Testing. Michele Owen, Ph.D Division of HIV/AIDS Prevention Centers for Disease Control & Prevention New Generation of Nucleic Acid Testing Michele Owen, Ph.D Division of HIV/AIDS Prevention Centers for Disease Control & Prevention Percentage (%) Persons Living with Diagnosed or Undiagnosed HIV Infection

More information

on October 4, 2018 by guest

on October 4, 2018 by guest JCM Accepts, published online ahead of print on 3 July 2012 J. Clin. Microbiol. doi:10.1128/jcm.01249-12 Copyright 2012, American Society for Microbiology. All Rights Reserved. 1 Title: Performance of

More information

Comparability and quality of experimental data under different quality systems. S. Caroli Istituto Superiore di Sanità Rome

Comparability and quality of experimental data under different quality systems. S. Caroli Istituto Superiore di Sanità Rome Comparability and quality of experimental data under different quality systems S. Caroli Istituto Superiore di Sanità Rome Programme of this presentation Part I. Background information Part II. Key aspects

More information

Diagnostic Methods of HBV and HDV infections

Diagnostic Methods of HBV and HDV infections Diagnostic Methods of HBV and HDV infections Zohreh Sharifi,ph.D Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine Hepatitis B-laboratory diagnosis Detection

More information

NAT / BLOOD SCREENING - PRODUCT RANGE

NAT / BLOOD SCREENING - PRODUCT RANGE NAT / BLOOD SCREENING - PRODUCT RANGE QC Sample Name Analytes Assay / Instrument Page QConnect TriScreen Roche cobas TaqScreen MPX Test, v 2.0 (s201) Roche cobas MPX Test (6800/8800) QConnect Grifols Ultrio

More information

QUALITY CONTROL Infectious Disease

QUALITY CONTROL Infectious Disease QUALITY CONTROL Infectious Disease 1 Infectious Disease Quality Control The human based material used in the production of our Quality Controls is sourced from the Taiwan Blood Services Foundation (TBSF).

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Issue date: 17 August 2016 Worcestershire Royal Hospital Contact: Peter Jackson Microbiology Laboratory Tel: +44 (0) 1905 760192 Ext 30659

More information

Figure S1. Standard curves for amino acid bioassays. (A) The standard curve for leucine concentration versus OD600 values for L. casei.

Figure S1. Standard curves for amino acid bioassays. (A) The standard curve for leucine concentration versus OD600 values for L. casei. Figure S1. Standard curves for amino acid bioassays. (A) The standard curve for leucine concentration versus OD600 values for L. casei. (B) The standard curve for lysine concentrations versus OD600 values

More information

BEIPH Final Report. QCMD 2009 Neisseria gonorrhoeae (NGDNA09) EQA Programme

BEIPH Final Report. QCMD 2009 Neisseria gonorrhoeae (NGDNA09) EQA Programme QUALITY CONTROL for MOLECULAR DIAGNOSTICS Block 4, Kelvin Campus, West of Scotland Science Park, Glasgow, G20 0SP Scotland Tel: +44 (0) 141 945 6474 Fax: +44 (0) 141 945 5795 www.qcmd.org info@qcmd.org

More information

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee College of American Pathologists (CAP) GH5 Survey Data: (updated 8/17) The American Diabetes Association (ADA) recommends that The A1C test should be performed using a method that is certified by the NGSP.

More information

Chlamydia trachomatis

Chlamydia trachomatis Chlamydia trachomatis 2012 EQA Programme A Final Report QAB004101 (CTDNA12A) Dr Anton M van Loon Scientific Experts on behalf of QCMD Report authorised by the QCMD Executive in May 2012 A UKAS accredited

More information

Transfusion Medicine (Comprehensive, Limited) J, J1

Transfusion Medicine (Comprehensive, Limited) J, J1 www.cap.org Transfusion Medicine Analytes/procedures in bold type are regulated for proficiency testing by the Centers for Medicare & Medicaid Services (CMS). Transfusion Medicine (Comprehensive, Limited)

More information

Case Studies, or Verification Vignettes

Case Studies, or Verification Vignettes Case Studies, or Verification Vignettes 1 Vignette #1 Change from One Automated AST to Another Your lab is changing from one FDA-cleared automated AST to another Is a verification study required? 2 Yes

More information

HBV-DNA reference panels

HBV-DNA reference panels HBV-DNA reference panels The kit insert contains a detailed protocol and should be read carefully before testing the run control to ensure optimal performance Table of contents Overview HBV-DNA panels

More information

Evaluation of Antibacterial Effect of Odor Eliminating Compounds

Evaluation of Antibacterial Effect of Odor Eliminating Compounds Evaluation of Antibacterial Effect of Odor Eliminating Compounds Yuan Zeng, Bingyu Li, Anwar Kalalah, Sang-Jin Suh, and S.S. Ditchkoff Summary Antibiotic activity of ten commercially available odor eliminating

More information

Cytomegalovirus (CMV) Viral Load in Bronchoalveolar Lavage Fluid (BALF) and Plasma to Diagnose Lung Transplant Associated CMV Pneumonia

Cytomegalovirus (CMV) Viral Load in Bronchoalveolar Lavage Fluid (BALF) and Plasma to Diagnose Lung Transplant Associated CMV Pneumonia Cytomegalovirus (CMV) Viral Load in Bronchoalveolar Lavage Fluid (BALF) and Plasma to Diagnose Lung Transplant Associated CMV Pneumonia I.P. Lodding 1,2, H.H. Schultz 3, J.U. Jensen 1,5, C. Andersen 4,

More information

GUIDE TO THE EVALUATION OF COMMUTABILITY OF CONTROL MATERIALS

GUIDE TO THE EVALUATION OF COMMUTABILITY OF CONTROL MATERIALS GUIDE TO THE EVALUATION OF COMMUTABILITY OF CONTROL MATERIALS Ferruccio Ceriotti Servizio di Medicina di Laboratorio, Ospedale San Raffaele, Milano F. Ceriotti, Milano, 27-11-2015 2 Preamble Most of the

More information

Received 8 January 2007/Returned for modification 20 February 2007/Accepted 4 June 2007

Received 8 January 2007/Returned for modification 20 February 2007/Accepted 4 June 2007 JOURNAL OF CLINICAL MICROBIOLOGY, Aug. 2007, p. 2529 2536 Vol. 45, No. 8 0095-1137/07/$08.00 0 doi:10.1128/jcm.00058-07 Copyright 2007, American Society for Microbiology. All Rights Reserved. Comparison

More information

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee College of American Pathologists (CAP) GH5 Survey Data: (updated 12/17) The American Diabetes Association (ADA) recommends that The A1C test should be performed using a method that is certified by the

More information

Point of Care Tests for respiratory viruses: impact on clinical outcomes of patients

Point of Care Tests for respiratory viruses: impact on clinical outcomes of patients Point of Care Tests for respiratory viruses: impact on clinical outcomes of patients Dr Sacha Stelzer-Braid Postdoctoral Scientist Virology Research Laboratory (VRL), UNSW and POWH @DrSachaSB Outline 1.

More information

Principles of In Vitro Diagnostic (IVD) Medical Devices Classification

Principles of In Vitro Diagnostic (IVD) Medical Devices Classification Technical Reference: TR-006 Date of Issue: 1 Dec. 2009 Principles of In Vitro Diagnostic (IVD) Medical Devices Classification Technical Reference: TR-006 Department of Health The G overnment of the Hong

More information

Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300

Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300 Product

More information

VQA Control SOP Version 4.0 Roche Amplicor HIV-1 DNA Test, v August 2007

VQA Control SOP Version 4.0 Roche Amplicor HIV-1 DNA Test, v August 2007 1. PRINCIPLE 1.1. The Virology Quality Assurance (VQA) Laboratory provides external cell pellet controls for use in the validation of assays that detect HIV proviral DNA. 1.2. HIV seronegative peripheral

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 15197 First edition 2003-05-01 In vitro diagnostic test systems Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus Systèmes d'essais

More information

Retrospective and Prospective Verification of the Cepheid Xpert Flu Assay

Retrospective and Prospective Verification of the Cepheid Xpert Flu Assay JCM Accepts, published online ahead of print on 20 July 2011 J. Clin. Microbiol. doi:10.1128/jcm.01162-11 Copyright 2011, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights

More information

GEX Technical Information Report

GEX Technical Information Report Transfer Standard Alanine Study September 2017 Background Ionizing radiation is used to produce various desired effects in products. Examples of applications include; the sterilization of medical products,

More information

AmpliX HBV Quantitative

AmpliX HBV Quantitative Instructions for use REAL TIME PCR DETECTION AND QUANTITATION KIT OF HEPATITIS B VIRUS DNA Research Use Only (RUO) (Lyo-format) VBD0595 96 rcs valid from May 2013 Explanation of symbols used in labeling

More information

BEIPH Final Report. EQA Programme 2011 Chlamydia trachomatis B (CTDNA11B) Prepared on behalf of QCMD and its Scientific Council October 2011

BEIPH Final Report. EQA Programme 2011 Chlamydia trachomatis B (CTDNA11B) Prepared on behalf of QCMD and its Scientific Council October 2011 BEIPH Final Report EQA Programme 2011 Chlamydia trachomatis B (CTDNA11B) Prepared on behalf of QCMD and its Scientific Council October 2011 Not to be reproduced or quoted without permission of QCMD. Any

More information

National Screening laboratory Sanquin The use of NAT in blood donation screening in The Netherlands. TransMed conference Bhopal 18 November 2016

National Screening laboratory Sanquin The use of NAT in blood donation screening in The Netherlands. TransMed conference Bhopal 18 November 2016 Dr. Anton van Weert National Screening laboratory Sanquin The use of NAT in blood donation screening in The Netherlands TransMed conference Bhopal 18 Introduction Thank you! Anton van Weert, PhD, MBA Manager

More information

HPV Testing What are EQAS and QC data telling us?

HPV Testing What are EQAS and QC data telling us? HPV Testing What are EQAS and QC data telling us? Vincini GA and Cabuang LM NRL, Melbourne, Australia Pathology Update 24 February 2019 HPV Screening 2017 Molecular testing for human papillomavirus (HPV)

More information