1 JOURNAL OF CLNCAL MCROBOLOGY, Nov. 1993, p /93/ $02.00/0 Copyright 1993, American Society for Microbiology Vol. 31, No. 11 Analysis of Discordant Test Results among Five Second-Generation Assays for Anti-Hepatitis C Virus Antibodies Also Tested by Polymerase Chain Reaction-RNA Assay and Other Laboratory and Clinical Tests for Hepatitis. NAKAGR,1 K. CHHARA,l* K. OHMOTO,2 M. HROKAWA,3 AND N. MATSUDA' Department of Clinical Pathology, 1 Department of Gastroenterology,2 and Department of Pathology,3 Kawasaki Medical School, Okayama, Japan Received 6 April 1993/Returned for modification 27 May 1993/Accepted 29 July 1993 The diagnostic performances of five commercially available second-generation assays for anti-hepatitis C virus antibody, two enzyme-linked immunosorbent assays, one enzyme immunoassay, and two particle agglutination assays (passive hemagglutination assay and particle agglutination assay), were evaluated. Among 104 samples from healthy subjects and 300 consecutive samples from patient ordered for routine determinations of anti-hepatitis C virus antibody in serum, assay results showed variable degrees of discordance for 17 samples (4.2%). These 17 samples were further tested by an immunoblot assay, the polymerase chain reaction-rna assay, and the hemagglutination inhibition assay. Four of the 17 samples were regarded as true positive, since all supplementary assays and clinical data indicated active hepatitis C virus infection. Another five samples were considered false positive because no confirmatory evidence was obtained from the laboratory analysis or clinical data. The remaining eight samples were negative for hepatitis C virus RNA, but the results of the other supplementary tests were indeterminate. Some of these samples with indeterminate results may have been from patients with subclinical cases of disease who spontaneously recovered from hepatitis with persistent anti-hepatitis C virus antibody in their sera. Shortly after the nucleotide sequence of the hepatitis C virus (HCV) genome was identified by Choo et al. (1) in 1989, the first enzyme-linked immunosorbent assay (ELSA) system for the detection of anti-hcv antibody (anti-hcv- Ab) was developed by Kuo et al. (5) by using the recombinant HCV C100-3 antigen. Anti-HCV-Ab was detected in a majority of patients with non-a, non-b hepatitis. The assay contributed greatly not only to clarification of the behavior of the elusive HCV but also to the identification of people who are possibly at risk of transmitting or acquiring HCV infection through blood products. The specificity and sensitivity of the assay, however, are not sufficient, and many false-positive results have been reported, especially in patients with autoimmune hepatitis (2, 4, 7). Furthermore, detection of seroconversion in patients with acute HCV infection is often delayed until 3 months to 1 year after the exposure (8). To overcome these problems, new assay systems for anti-hcv-ab (second-generation assays) have recently been developed and have become available for routine use. The assays use various mixtures of recombinant HCV antigens and can detect a broader range of anti-hcv-abs. n the study described here, the diagnostic performances of five commercially available second-generation assays for anti-hcv-ab were evaluated and compared with the results of the polymerase chain reaction (PCR) for serum HCV and with those of other supplemental assays and clinical evidence of hepatitis. * Corresponding author MATERALS AND METHODS Materials. For the analysis we used 300 consecutive serum samples routinely submitted to our clinical laboratory, which serves a 750-bed university hospital, for measurement of anti-hcv-ab. Many of the serum samples were from the departments of gastroenterology, urology, and surgery. Samples were also taken from 104 healthy adults (30 males, 74 females; age range, 22 to 40 years) with normal alanine aminotransferase and aspartate aminotransferase levels and with no previous history of hepatobiliary disorders or blood transfusion. All of the samples were stored at -80 C until the time of the assays. Reagents and assay methods. All samples were tested for anti-hcv-ab by the following five assays: the mucheck ELSA (nternational Reagents Corp., Kobe, Japan), the Ortho ELSA (ELSA ; Ortho Diagnostic Systems nc., Tokyo, Japan), the Abbott enzyme immunoassay (EA; EA ; Abbott Diagnostics Division), a passive hemagglutination assay (PHA; Dainabot Corp. Ltd., Tokyo, Japan), and a particle agglutination assay (PA; Ortho Diagnostic Systems nc.). A map of the amino acid sequences of the recombinant HCV antigens used in each assay system is shown in Fig. 1. ELSA and EA. n both the mucheck and ELSA ELSAs, microplate wells coated with the HCV antigens were used. n the mucheck ELSA, 20,ul of a serum sample was added to 200,u of dilution buffer in the wells. After incubation for 1 h at 37 C, the wells were thoroughly washed to remove the unbound antibodies and serum, and then 100 p,l of a peroxidase-conjugated antibody solution specific for human immunoglobulin G (gg) was added to each well. After another incubation for 30 min at 37 C, the unbound

2 VOL. 31, 1993 DSCORDANCE AMONG FVE ANT-HCV ANTBODY ASSAYS ' - C El/S E2 / NS1 NS2 NS3 NS NS5 K3' 301 laa Ortho ELSA C c cloo c33c Ortho PA Abbott EA Dainabot PHA mucheck c PHCV c c33c BCD phcv cloo C-11 C ? ? FG. 1. Epitope maps of the recombinant antigens used in the five anti-hcv-ab assays. The distribution of the epitopes corresponding to the recombinant antigens is shown for the five anti-hcv-ab assay systems. The abbreviations and the amino acid sequence numbers were adopted from those shown by Houghton et al. (3a); C, core region; El, envelope; NS, nonstructural region. fraction of the conjugate was washed away and 100,ul of a solution of hydrogen peroxide and o-phenylenediamine was added to each well. n the presence of a bound conjugate, the o-phenylenediamine was oxidized to give a colored end product. The enzyme-substrate reaction was terminated by the addition of 100,u of 2 N sulfuric acid. The A492 of the final solution was measured. A sample was considered to be positive when the absorbance exceeded the cutoff value determined from the following formula: cutoff value = NCx (0.2)- PCx, where NCx and PCx represent the mean absorbance of three negative controls and that of three positive controls, respectively. n the ELSA, 20,ul of the serum sample was added to 200,ul of dilution buffer in the wells. After incubation for 1 h at 37 C, the wells were thoroughly washed to remove the unbound fraction, and then 200 p1 of a peroxidase-conjugated anti-human gg solution was added to each well. After another incubation for 1 h at 37 C, the microplate was washed and 200 pl of a solution of hydrogen peroxide and o-phenylenediamine was added to each well. The enzymesubstrate reaction was terminated after 30 min by the addition of 50,ul of 4 N sulfuric acid. The A492 of the sample was measured. The cutoff value was set by the following formula: cutoff value = NCx 0.600, where NCx represents the mean of three negative control readings. The constant was set by the manufacturer to keep the frequency of false-positive results at an optimal level. n the EA, 10 pu1 of the serum sample was diluted 41-fold in a polyethylene test tube. Two hundred microliters of the diluted serum was transferred to a special Abbott plate well. Then, a polystyrene bead coated with HCV antigens was added and the mixture was incubated for 1 h at 40 C. After washing the bead, a solution of peroxidase-conjugated antibody directed against human gg was added, and the mixture was incubated for an additional 30 min at 40 C. The unbound conjugate was then removed and a solution containing o-phenylenediamine and hydrogen peroxide was added. The reaction was terminated by adding 1 ml of 1 N sulfuric acid. The color intensity was measured as described above for the other two methods. Samples were considered positive when their absorbances exceeded the cutoff values determined from the following formula: cutoff value = NCx (0.25)PCx, where NCx and PCx represent the mean absorbances of three negative controls and three positive controls, respectively. PHA and PA assays. The PHA and PA assays were performed in microplates with V-shaped and U-shaped wells, respectively. A fuzzy layer of agglutinated particles is formed at the bottom of the wells when anti-hcv-ab is present in serum, whereas a tight button pattern appears in the absence of the antibody. For the PHA assay, 25 pul of serum was diluted 32-fold in a well by using a micropipetter. Twenty-five microliters of the diluted serum was then transferred to another well, and 25 pul of erythrocytes coated with the HCV antigens was added by using a microdropper. n the PA assay, 25 p,l of serum was diluted 8- or 16-fold. Twenty-five microliters of serum diluted to 1:16 was transferred to a well and was mixed with 25 p,l of gelatin particles coated with the HCV antigens (sensitized gelatin particles). As a control for each sample, 25 p,l of serum diluted to 1:8 was reacted with unsensitized gelatin particles specially coated with superoxide dismutase, a protein used in the production of the recombinant HCV antigens and, therefore, a possible target of a nonspecific reaction in the assay. After the plate was shaken, it was kept at room temperature for 2 h, and then the agglutination pattern was judged by inspection. All the reagents were used within 3 days after preparation

3 2976 NAKAGR ET AL. to ensure their stability. The positive results of the PHA assay were confirmed by an antibody inhibition assay supplied by Dainabot Corp. Ltd. This assay is designed to detect nonspecific reactions by preincubating anti-hcv-ab-positive sera with the recombinant antigens used in the PHA assay. RBA-2. All samples showing positive test results in any one of the five anti-hcv-ab assays were further tested by the second-generation recombinant immunoblot assay (RBA-2; Ortho Co.) to analyze the reactivity of the sample antibodies to four recombinant HCV antigens attached discretely to a nitrocellulose strip. PCR-RNA. The PCR-RNA assay for HCV was performed by using a modification of the procedure described by Garson et al. (3), which took advantage of the highly conserved nucleotide sequences within a 5'-noncoding region of the HCV genome. RNA was extracted from 100,ul of serum by the acid guanidium thiocyanate-phenol-chloroform method and was converted to cdna with reverse transcriptase. The cdna was then amplified by the nested PCR method by using two sets of primers. The sequences of the outer primers were 5'-CTGTCTTCACGCAGAAAGCG-3' (sense; nucleotide positions 41 to 60 in the HCV genome according to the revised numbering system of Okamoto et al. [6]) and 5'-CACTCGCAAGCACCCTATCA-3' (antisense; nucleotide positions 277 to 296). The inner primers were 5'- CGTTAGTATGAGTGTCGTGC-3' (sense; nucleotide positions 72 to 91) and 5'-AGGCATTGAGCGGG1TlATC-3' (antisense; nucleotide positions 184 to 203) (8). Thirty cycles of denaturation for 2 min at 94 C, annealing for 1 min at 60 C, and extension for 2 min at 72 C were carried out. The PCR products were electrophoresed on a 2% agarose gel containing ethidium bromide, and the resultant pattern was photographed. RESULTS Spectrum of anti-hcv-ab specificity in reference to the immunoblot assays. Prior to the present study, we performed the RBA-2 on samples which screened positive for anti- HCV-Ab by the first-generation assay and identified three patterns of combinations of anti-hcv-abs. The first pattern was characterized by the specificity of the anti-hcv-ab almost exclusively to the core antigen C22-3 (Table 1). Results for two typical samples belonging to this pattern are shown in Table 1 along with the corresponding results of the five assays. The two samples were clearly detected by all methods, and there was no major difference in the titer, which was determined by serial dilution from 1:1 to 1:64. The second pattern was a combination of anti-hcv-abs which possess specificity only to the nonstructural (NS4 region) antigen designated C As shown for two typical samples in Table 1, the results for both samples were negative by the mucheck ELSA but were mixed by the EA and PA methods. On the other hand, the ELSA and PHA methods gave clearly positive results even at higher dilutions. Anti-HCV-Abs which belonged to the third pattern showed specificity to all four antigens covered in the RBA-2. All five assays gave positive results for the two typical samples for which the results are shown in Table 1. Summary of the results of the five anti-hcv-ab assays. Comparisons of the results from the five HCV-Ab assays with samples from patients and healthy subjects are shown in Table 2. The test results were negative by all of the assays J. CLN. MCROBOL. for 222 samples. The results were positive by all of the assays for 62 samples. All samples were confirmed to be HCV positive from the positive results of subsequent PCR- RNA assays. For 17 subjects, the results of the five assays showed various degrees of discordance. One of the healthy subjects whose serum was positive by the mucheck ELSA was 1 of the 17 subjects whose sera had various degrees of discordance by the five assays. Analyses of samples with discordant results. All of the 17 samples with discordant results showing positive results by any one of the five assays were further tested for their antibody spectra by the RBA-2 and for the presence of viral RNA in serum by the PCR-RNA assay. Some of them were also tested by the hemagglutination inhibition assay to exclude any nonspecific reaction by the PHA method. The summary of the results for these 17 patients is shown in Table 3. Sera from 4 of the 17 patients were found to be positive for HCV RNA by PCR, and 7 of the 9 serum samples which were tested for anti-hcv-ab by the inhibition assay gave results in agreement with the results of the PHA assay. On the other hand, 5 of the 17 serum samples were nonreactive to all four HCV antigens arranged in the RBA-2. On the basis of the results of the supplemental assays, the validities of the five anti-hcv-ab assay results for those conflicting samples can be interpreted as follows. Since serum positivity by the PCR method rules in active infection and sets a "gold standard," the negative test results for patients 1 through 4 in Table 3 can be regarded as falsenegative ones, whereas the negative results for all three supplemental assays almost certainly rule out actual HCV infection. Hence, the results for patients 13 through 17 in Table 3 indicate false-positive results. On the other hand, we cannot make any definite comments regarding the data for patients 5 through 12 in Table 3 unless we turn to clinical evidence or other laboratory evidence of hepatic infection. By setting a positive PCR-RNA test result as a gold standard for active HCV infection, the sensitivity and specificity of each assay were calculated from the data in Table 2 with the results presented in the boxed area categorized by using the information in Table 3. They were, respectively, 97.0 and 97.9% for the mucheck ELSA method, 97.0 and 98.8% for ELSA, 93.9 and 100% for EA, 98.5 and 98.5% for PHA, and 100 and 99.1% for PA. Clinical and laboratory data for the samples with discordant results. The relevant clinical and laboratory data regarding possible hepatic infection for the 17 patients whose sera showed discordant results by the five assays are shown in Table 4. The first four patients, whose sera gave positive results for viral RNA, were actually diagnosed with acute or chronic hepatitis because of current or previous elevations in the levels of the transaminases. Histological evidence of infection was also obtained for all four of these patients. Among the remaining 13 patients (1 from the healthy group and the others with variable nonliver disorders), 12 patients had no clinical history of hepatitis at the time of the blood test for anti-hcv-ab. Three of the 13 patients had recent histories of blood transfusion, but all donor blood was found to be negative for anti-hcv-ab by a second-generation assay. As a matter of fact, there was no or only a slight elevation in serum transaminase levels in the 13 patients, with the exception of patient 17, who had a well-documented episode of transient hepatic ischemia secondary to circulatory shock. Furthermore, in response to the positive results for anti-hcv-ab, liver biopsies were performed in 3 of the

4 VOL. 31, 1993 DSCORDANCE AMONG FVE ANT-HCV ANTBODY ASSAYS 2977 TABLE 1. Antibody spectra and sensitivities of the five anti-hcv-ab assays compared with the result of an immunoblot assay' Pattern and mucheck ELSA Ortho ELSA Abbott EA Dainabot Ortho RBA-2 sample Dilution PHA PA sample ~~OD CO OD COT OD coi HA P C100-3 C33C C22-3 Core-positive pattern 1 2 NS4-positive pattern 3 4 Both core- and NS4-positive patterns [ 0.938] 2.78U l1.56 j F [ W w W >3.000 > ] Ljj [ _ ] _. - _ W _ >3.000 >10.00 >3.000 >5.00 >2.200 > >3.000 > >3.000 >5.00 >2.200 > >3.000 >10.00 >3.000 >5.00 >2.200 > >3.000 > >3.000 > >3.000 > , w 2 ± a On the basis of reactivity to four distinct epitopes (5-1-1, C100-3, C33C, and C22-3) in the immunoblot assay, anti-hcv-ab-positive sera were grouped into three patterns. The test results of two typical serum samples in the five anti-hcv-ab assays are shown for each pattern: those with almost exclusive specificity to the core antigen C22-3, those with specificity only to the nonstructural (NS4 region) antigen C100-3, and those with specificity to all four antigens distinguishable by RBA-2. Each sample was serially diluted. OD, optical density; CO, cutoff index. Superscript w's indicate a weakly positive reaction. Boxing indicates a positive test result.

5 2978 NAKAGR ET AL. J. CLN. MCROBOL. TABLE 2. Summary of results of the five anti-hcv-ab assays' No. of samples from: mucheck Ortho Abbott Dainabot Ortho Healthy Patient ELSA ELSA EA PHA PA controls samples (n = 104) (n = 300) a Test results that were below the cutoff value are indicated by a minus sign, and those that were above the cutoff value are indicated by a plus sign. The test results for the five assays were classified according to their patterns. The two rightmost columns represent the sums of each pattern for samples from healthy adults and patients. Boxing indicates samples exhibiting various degrees of discordance by the five assays. The sensitivity and specificity of the assay were calculated from the data in this table after classifying the data in the boxed area according to the results in Table 3 by setting a positive PCR-RNA test result as a "gold standard" for HCV infection. 13 patients, but the histological findings were negative for active liver disease for all 3 patients. Accordingly, among the 17 patients whose sera provided discordant results, the first 4 patients can also be regarded as true positive for HCV infection on clinical grounds, while for the remaining patients, the likelihood of active infection seemed to be very low. DSCUSSON Several second-generation assays for anti-hcv-ab detection are now available. Many of them use the principle of TABLE 3. ELSA or EA, but those that use the principle of particle agglutination are also in use. The latter assays use either erythrocytes (PHA) or gelatin particles (PA) as a solid support for the HCV antigens, allowing easy detection of the reaction without special equipment. There have, however, been no reports on comparisons of the ELSA or EA and PHA or PA methods. n the present study, we compared the results of the five anti-hcv-ab assays (two ELSAs, one EA, and two particle agglutination assays [PHA and PA]) that are commercially available in Japan. All of them had sufficient precision; intraassay variations in terms of the coefficient of variation for the two ELSAs and the one EA method were all within 6%. The reproducibilities of the PHA and PA methods were within a difference of plus or minus one well. The performances of the five methods were assessed from the results of RBA-2, the antibody inhibition assay, as well as by the nested PCR-RNA assay. Results of the five assays agreed very well for 387 of 404 samples tested. Among the 17 samples that gave discordant results, 4 were confirmed to be positive for HCV in serum by the PCR-RNA assay, and it was strongly suspected that the patients had active infections on the grounds of clinical information and the positive results by RBA-2. Since the PHA and PA methods consistently gave positive results for the four samples, the chance that these tests would overlook those patients with borderline infections seemed to be low. Samples from another 5 of the 17 patients with discordant results were found to be consistently negative by all the supplemental assays, and the patients had no clinical evidence of hepatitis. On the other hand, interpretation was not easy for the remaining eight patients whose serum samples had discordant results by the five assays. On clinical grounds, seven of them had no apparent history of hepatitis or transfusion of blood products untested for HCV. None underwent any form of interferon therapy, which frequently leads to the disappearance of HCV in serum with or without concomitant lowering of serum anti-hcv-ab levels. Liver tissues were Discordance among the five anti-hcv-ab assays and results of supplemental assaysa Patient mucheck Ortho Abbott Ortho Dainabot Antibody RBA-2 no. ELSA ELSA EA PA PHA inhibition HCV-RNA assay C22-3 C33C C SOD ()b 0.12(-) 0.31(-) W _ () 1.89() 0.62(-) W (-) 0.25(-) 0.33(-) W (-) 4.40() 0.92(-) W 2 _ () 0.01(-) 0.14(-) - - NT (-) 0.18(-) 0.20(-) (-) 0.24(-) 0.22(-) - NT (-) 0.10(-) 0.42(-) (-) 4.42() 0.46(-) 2 (*1) _ (-) 1.36() 0.62(-) - W _ (-) 1.02 () 0.80 (-) W _ NT ± (*2) () 2.04() 0.88(-) W 2 (*3) () 0.07(-) 0.32(-) - - NT () 0.12(-) 0.34(-) - - NT () 0.11(-) 0.13(-) - - NT () 0.14(-) 0.28(-) - - NT () 0.16(-) 0.35(-) - - NT a Test results for the 17 samples which gave discordant results by the five anti-hcv-ab assays. NT, not tested; w, weakly positive; SOD, superoxide dismutase. Some of the results for the core region obtained by RBA-2 were retested later. The indeterminate value () for C22-3 in serum sample 9 was negative 8 months later (*1), and that in serum sample 11 remained at the indeterminate level 6 months later (*2). The positive results for serum sample 12 decreased to the indeterminate level of in 10 months (*3). Repeated PCR-RNA tests carried out simultaneously by RBA-2 were also negative for the three serum b samples. Data in columns 2 through 4 are cutoff indices and their plus/minus judgments.

6 VOL. 31, 1993 DSCORDANCE AMONG FVE ANT-HCV ANTBODY ASSAYS 2979 TABLE 4. Clinical and laboratory data for serum samples from 17 patients with discordant results by the five anti-hcv-ab assaysa Patient ALT AST gm Past History of Crnc Liver no. Age (yr) Sex (U/iter) HA-Ab HBs-Ag history of blood Clinical diagnosis hepatitis biopsy hepatitis transfusion result 1 44 F 1, Acute hepatitis Hepatitis 2 11 F Chronic hepatitis Hepatitis 3 53 M Chronic hepatitis Hepatitis 4 70 F Chronic hepatitis Hepatitis 5 28 F None, found by chance M Head trauma - Normal 7 88 M Unknown fever 8 70 F Unknown fever - Normal 9 42 M Male infertility F Epilepsy F None, found by chance M Angina pectoris F Cholangiocarcinoma F Multiple cerebral infarction M Pulmonary tuberculosis F Multiple cerebral infarction M Lung cancer - Normal a F, female; M, male; ALT, alanine aminotransferase; AST, aspartate aminotransferase; HA-Ab, anti-hepatitis A virus antibody; HBs-Ag, hepatitis B virus surface antigen. obtained from three of the patients, but none was found to have histological evidence of hepatitis. Furthermore, their levels of transaminases were normal or only slightly elevated, and the levels of anti-hcv-ab in serum, in general, were only slightly above the cutoff values. On the basis of this evidence, active HCV infection among the patients seems very unlikely. The results of the supplemental assays, however, were mixed because serum from three of the eight patients showed indeterminate results for a core region antibody by RBA-2. Furthermore, the inhibition assay confirmed the validity of the PHA assay for four of the five PHA-positive samples tested. Consequently, there was still a possibility of actual HCV infection which could not be detected by the primers used for the PCR assay or which took a subclinical course and ameliorated spontaneously but with the persistence of anti-hcv-ab in serum. Although no appreciable differences were observed in the overall diagnostic sensitivity or specificity among the five methods, the numbers of false-positive or false-negative results were slightly lower in the particle agglutination assays. These may be attributable to the fact that the antigen-attached particles can react to both gm and gg and no distinction is possible between them during the detection step. n contrast, since the ELSA and the EA methods use enzyme-labeled anti-human antibodies which are directed against gg, they cannot detect the gm-type anti-hcv-abs. Regarding the supplemental tests for anti-hcv-ab-positive sera, the RBA-2 has been the most widely used (9, 10). There are, however, few reports on its performance for borderline cases such as those described here. Our results suggest that there are still some patients whose infections cannot be clearly classified by RBA-2, despite improvement in its performance from its first-generation counterpart. From a practical point of view, selection of one of the five assays depends on a laboratory's situation and size. n an emergency laboratory or a doctor's office, the PHA or PA assay is the method of choice, because they have sufficient sensitivity and rapidity and are convenient. For quantitative measurement of the antibody titer, however, these methods require serial dilution, and thus, the costs of the reagents cannot be ignored. On the other hand, the ELSAs or EA, which can be performed with fully automated equipment, are suitable for large laboratories. The level of anti-hcv-ab can be obtained as a continuous value within the dynamic ranges of the assays. ACKNOWLEDGMENTS We are grateful to nternational Reagents Corp., Dainabot Corp., and Ortho Diagnostic Systems nc. for generously supplying reagents and technical support. We also express our gratitude to S. Yamamoto and A. Harano, Kawasaki Medical School, for helpful comments on our work. REFERENCES 1. Choo, Q.-L., G. Kuo, A. J. Weiner, L. R. Overby, D. W. Bradley, and M. Houghton solation of a cdna clone derived from a blood borne non-a, non-b viral hepatitis genome. Science 244: Esteban, J.., R. Esteban, L. Viladomiu, J. C. Lupez-Talavera, A. Gonzalez, J. M. Hernandez, M. Roget, V. Vargas, J. Genesca, M. Buti, J. Guardia, M. Houghton, Q.-L. Choo, and G. Kuo Hepatitis C virus antibodies among risk groups in Spain. Lancet ii: Garson, J. A., R. S. Tedder, M. Briggs, P. Tuke, J. A. Glazebrook, A. Trute, D. Parker, J. A. J. Barbara, M. Contreras, and S. Aloysius Detection of hepatitis C viral sequences in blood donations by 'nested' polymerase chain reaction and prediction of infectivity. Lancet 335: a.Houghton, M., A. Weiner, J. Han, G. Kuo, and Q.-L. Choo mplications for diagnosis, development and control of viral disease. Hepatology 14: keda, Y., G. Toda, N. Hashimoto, and K. Kurokawa Antibody to superoxidase dismutase, autoimmune hepatitis and antibody tests for hepatitis C virus. Lancet 335: Kuo, G., Q.-L. Choo, H. J. Alter, G. L. Gitnick, A. G. Redeker, R. H. Purcell, T. Miyamura, J. L. Dienstag, M. J. Alter, C. E. Stevens, G. E. Tegtmeier, F. Bonino, M. Cdombo, W.-S. Lee, C. Kuo, K. Berger, J. R. Shuster, L. R. Overby, D. W. Bradley, and M. Houghton An assay for circulating antibodies to a major etiologic virus of human non-a, non-b hepatitis. Science 244: Okamoto, H., S. Okada, Y. Sugiyama, S. Yotsumoto, T. Tanaka, H. Yoshizawa, F. Tsuda, Y. Miyakawa, and M. Mayupni The 5'-terminal sequence of the hepatitis C virus genome. Jpn. J. Exp. Med. 60:

7 2980 NAKAGR ET AL. 7. Onji, M., T. Kikuchi, K. Michitaka,. Saito, T. Miyamura, and Y. Ohta Detection of hepatitis C virus antibody in patients with autoimmune hepatitis and other chronic liver diseases. Gastroenterol. Jpn. 26: Saito, M., A. Hasegawa, T. Kashiwakuma, M. Kohara, M. Sugi, K. Miki, T. Yamamoto, H. Mori, Y. Ohta, E. Tanaka, K. Kiyosawa, S. Furuta, M. Wakashima, S. Tanaka, and N. Hattori Performance of an enzyme-linked immunosorbent assay system for antibodies to hepatitis C virus with two new antigens J. CLN. MCROBOL. (cll/c7). Clin. Chem. 38: Yuki, N., N. Hayashi, H. Hagiwara, T. Takehara, M. Oshita, A. Kasahara, H. Fusamoto, and T. Kamada Serodiagnosis of chronic hepatitis C in Japan by second-generation recombinant immunoblot assay. J. Hepatol. 17: Yun, Z. B., G. Lindh, 0. Weiland, B. Johansson, and A. Sonnerborg Detection of hepatitis C virus (HCV) RNA by PCR related to HCV antibodies in serum and liver histology in Swedish blood donors. J. Med. Virol. 39:57-61.

Polymerase Chain Reaction RNA Assays To Establish

Polymerase Chain Reaction RNA Assays To Establish JOURNAL OF CLINICAL MICROBIOLOGY, Aug. 1992, p. 2145-2149 0095-1137/92/082145-05$02.00/0 Copyright 1992, American Society for Microbiology Vol. 30, No. 8 Use of Aminotransferase, Hepatitis C Antibody,

More information

DETECTION OF HEPATITIS C VIRUS cdna SEQUENCE BY THE POLYMERASE CHAIN REACTION IN HEPATOCELLULAR CARCINOMA TISSUES

DETECTION OF HEPATITIS C VIRUS cdna SEQUENCE BY THE POLYMERASE CHAIN REACTION IN HEPATOCELLULAR CARCINOMA TISSUES Jpn. J. Med. Sci. Biol., 43, 89-94, 1990. Short Communication DETECTION OF HEPATITIS C VIRUS cdna SEQUENCE BY THE POLYMERASE CHAIN REACTION IN HEPATOCELLULAR CARCINOMA TISSUES Tetsuo YONEYAMA, Kenji TAKEUCHI,

More information

Identification of Microbes Lecture: 12

Identification of Microbes Lecture: 12 Diagnostic Microbiology Identification of Microbes Lecture: 12 Electron Microscopy 106 virus particles per ml required for visualization, 50,000-60,000 magnification normally used. Viruses may be detected

More information

Editorial. Hepatitis C: From Laboratory to Bedside

Editorial. Hepatitis C: From Laboratory to Bedside Editorial Hepatitis C: From Laboratory to Bedside It has been 15 years since Feinstone and coworkers' at the National Institutes of Health described a type of hepatitis occurring in recipients of blood

More information

Mouse HBsAg(Hepatitis B Virus Surface Antigen) ELISA Kit

Mouse HBsAg(Hepatitis B Virus Surface Antigen) ELISA Kit Mouse HBsAg(Hepatitis B Virus Surface Antigen) ELISA Kit Catalogue No.: EM0002 Size: 96T Reactivity: Mouse Application: This immunoassay kit allows for the qualitative determination of HBsAg in Mouse serum

More information

The Alphabet Soup of Viral Hepatitis Testing

The Alphabet Soup of Viral Hepatitis Testing The Alphabet Soup of Viral Hepatitis Testing August 18, 2011 Patricia Slev, PhD, DABCC Medical Director, Serologic Hepatitis and Retrovirus Laboratory, ARUP Laboratories Assistant Professor of Pathology,

More information

HBV Core and Core-Related Antigen Quantitation in Chinese Patients with. Chronic Hepatitis B Genotype B and C Virus Infection

HBV Core and Core-Related Antigen Quantitation in Chinese Patients with. Chronic Hepatitis B Genotype B and C Virus Infection Title page HBV Core and Core-Related Antigen Quantitation in Chinese Patients with Chronic Hepatitis B Genotype B and C Virus Infection Short Title: Quantitation of HBc and HBcrAg in Chinese patients Akinori

More information

Comparison between ELISA and chemiluminescence immunoassay for the detection of Hepatitis C virus antibody

Comparison between ELISA and chemiluminescence immunoassay for the detection of Hepatitis C virus antibody Original Research Article DOI: 10.18231/2394-5478.2017.0078 Comparison between ELISA and chemiluminescence immunoassay for the detection of Hepatitis C virus antibody Pampi Majumder 1, Anup Kumar Shetty

More information

Changes in Hepatitis C Virus (HCV) Antibody Status in Patients with Chronic Hepatitis C after Eradication of HCV Infection by Interferon Therapy

Changes in Hepatitis C Virus (HCV) Antibody Status in Patients with Chronic Hepatitis C after Eradication of HCV Infection by Interferon Therapy MAJOR ARTICLE Changes in Hepatitis C Virus (HCV) Antibody Status in Patients with Chronic Hepatitis C after Eradication of HCV Infection by Interferon Therapy Hidenori Toyoda, 1 Takashi Kumada, 1 Seiki

More information

Serological Markers of Posttransfusion Hepatitis C Viral Infection

Serological Markers of Posttransfusion Hepatitis C Viral Infection JOURNAL OF CLINICAL MICROBIOLOGY, Mar. 1992, p. 552-556 Vol. 3, No. 3 95-1137/92/3552-5$2./ Copyright X) 1992, American Society for Microbiology Serological Markers of Posttransfusion Hepatitis C Viral

More information

False Positive Tests for Anti-Hepatitis C Antibodies and the Problem of Notifying Blood Donors

False Positive Tests for Anti-Hepatitis C Antibodies and the Problem of Notifying Blood Donors International Journal of Epidemiology O International Epidemlological Association 1996 Vol. 25, o. Printed in Great Britain False Positive Tests for Anti-Hepatitis C Antibodies and the Problem of otifying

More information

Equilibrium Centrifugation Studies of Hepatitis C Virus: Evidence for Circulating Immune Complexes

Equilibrium Centrifugation Studies of Hepatitis C Virus: Evidence for Circulating Immune Complexes JOURNAL OF VIROLOGY, Apr. 1993, p. 1953-1958 0022-538X/93/041953-06$02.00/0 Copyright ) 1993, American Society for Microbiology Vol. 67, No. 4 Equilibrium Centrifugation Studies of Hepatitis C Virus: Evidence

More information

Hepatitis A virus IgM ELISA Kit

Hepatitis A virus IgM ELISA Kit Hepatitis A virus IgM ELISA Kit Catalog Number KA0285 96 assays Version: 04 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

Hepatitis B surface antigen Ab ELISA Kit

Hepatitis B surface antigen Ab ELISA Kit Hepatitis B surface antigen Ab ELISA Kit Catalog Number KA0287 96 assays Version: 22 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3

More information

Documentation, Codebook, and Frequencies

Documentation, Codebook, and Frequencies 2 Documentation, Codebook, and Frequencies Laboratory Component: Hepatitis B: core antibody, surface antibody and surface antigen; Hepatitis C: confirmed antibody; Hepatitis D antibody Survey Years: 2003

More information

HBeAg and HBeAg Ab ELISA Kit

HBeAg and HBeAg Ab ELISA Kit HBeAg and HBeAg Ab ELISA Kit Catalog Number KA0290 96 assays Version: 17 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay... 3

More information

INSTRUCTION MANUAL FOR HBsAg SUBTYPE EIA

INSTRUCTION MANUAL FOR HBsAg SUBTYPE EIA INSTRUCTION MANUAL FOR HBsAg SUBTYPE EIA EIA based hepatitis B surface antigen subtyping kit with monoclonal antibodies I. Kit configuration 1. Microplate coated with anti-hbs a (96 wells)... 1 plate 2.

More information

Follow-up of hepatitis C virus infection in chimpanzees: determination of viraemia and specific humoral immune response

Follow-up of hepatitis C virus infection in chimpanzees: determination of viraemia and specific humoral immune response Journal of General Virology (1992), 73, 1015-1019. Printed in Great Britain 1015 Follow-up of hepatitis C virus infection in chimpanzees: determination of viraemia and specific humoral immune response

More information

Evaluation of Interferon Treatment in Cirrhotic Patients with Hepatitis C

Evaluation of Interferon Treatment in Cirrhotic Patients with Hepatitis C Evaluation of Interferon Treatment in Cirrhotic Patients with Hepatitis C Tatsuya IDE, Michio SATA, Hiroshi SUZUKI, Shiroh MURASHIMA, Ichiroh MIYAJIMA, Miki SHIRACHI and Kyuichi TANIKAWA The Second Department

More information

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Murex HIV Ag/Ab Combination Number: PQDx

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Murex HIV Ag/Ab Combination Number: PQDx WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT Product: Murex HIV Ag/Ab Combination Number: PQDx 0144-043-00 Abstract Murex HIV Ag/Ab Combination with product codes 7G79-09 (GE41,

More information

Diagnostic Methods of HBV and HDV infections

Diagnostic Methods of HBV and HDV infections Diagnostic Methods of HBV and HDV infections Zohreh Sharifi,ph.D Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine Hepatitis B-laboratory diagnosis Detection

More information

WHO Prequalification of Diagnostics Programme PUBLIC REPORT

WHO Prequalification of Diagnostics Programme PUBLIC REPORT WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: Murex HBsAg Version 3 with Murex HBsAg Confirmatory Version 3 Number: PQDx 0121-043-00 Abstract Murex HBsAg Version 3 with Murex HBsAg

More information

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Murex anti-hcv (version 4.0) Number: PQDx

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Murex anti-hcv (version 4.0) Number: PQDx WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT Product: Murex anti-hcv (version 4.0) Number: PQDx 0164-059-00 Abstract Murex anti-hcv (version 4.0) with product codes 7F51-01 and

More information

Hepatitis A virus IgM ELISA Kit

Hepatitis A virus IgM ELISA Kit Hepatitis A virus IgM ELISA Kit Catalog Number KA0285 96 assays Version: 06 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

Chronic hepatitis C: new diagnostic tools and therapeutic strategies Damen, M.

Chronic hepatitis C: new diagnostic tools and therapeutic strategies Damen, M. UvA-DARE (Digital Academic Repository) Chronic hepatitis C: new diagnostic tools and therapeutic strategies Damen, M. Link to publication Citation for published version (APA): Damen, M. (1999). Chronic

More information

HIV-1 p24 ELISA Kit. purified polyclonal antibody raised against the full length recombinant p24 is used.

HIV-1 p24 ELISA Kit. purified polyclonal antibody raised against the full length recombinant p24 is used. HIV-1 p24 ELISA Kit 80-001 1 kit 96 assays This kit can measure the amount of HIV-1 Gag p24 antigen in cell culture medium handily by a sandwich ELISA (Enzyme Linked Immunosorbent Assay) method. p24 antigen

More information

Guidance for Industry

Guidance for Industry Guidance for Industry Lookback for Hepatitis C Virus (HCV): Product Quarantine, Consignee Notification, Further Testing, Product Disposition, and Notification of Transfusion Recipients Based on Donor Test

More information

IVD information *Droppers for the sensitized and control cells. Not for use other than dispensing the sensitized and control cells.

IVD information *Droppers for the sensitized and control cells. Not for use other than dispensing the sensitized and control cells. In Vitro Diagnostic Reagent Instruction Manual of Diagnostic Reagent for Determination of anti-hbs Thoroughly read this instruction manual before use of this kit Background of the development and features

More information

HIV-1 p24 ANTIGEN CAPTURE ASSAY

HIV-1 p24 ANTIGEN CAPTURE ASSAY HIV-1 p24 ANTIGEN CAPTURE ASSAY Enzyme Immunoassay for the detection of Human Immunodeficiency Virus Type 1 (HIV-1) p24 in tissue culture media. Catalog # 5421 株式会社東京未来スタイル Tokyo Future Style, Inc 305-0047

More information

HEPATITIS C VIRUS (HCV) IS A BLOOD-BORNE. Laboratory diagnosis of viral hepatitis C The Sultan Qaboos University Hospital experience

HEPATITIS C VIRUS (HCV) IS A BLOOD-BORNE. Laboratory diagnosis of viral hepatitis C The Sultan Qaboos University Hospital experience SQU JOURNAL FOR SCIENTIFIC RESEARCH: MEDICAL SCIENCES 2003 VOL 5, NO. 1 2, 15 20 SULTAN QABOOS UNIVERSITY Laboratory diagnosis of viral hepatitis C The Sultan Qaboos University Hospital experience *Said

More information

Human HBcAb IgM ELISA kit

Human HBcAb IgM ELISA kit Human HBcAb IgM ELISA kit Catalog number: NR-R10163 (96 wells) The kit is designed to qualitatively detect HBcAb IgM in human serum or plasma. FOR RESEARCH USE ONLY. NOT FOR DIAGNOSTIC OR THERAPEUTIC PURPOSES

More information

for detecting antibody to hepatitis B virus core antigen

for detecting antibody to hepatitis B virus core antigen Journal of Clinical Pathology, 1978, 31, 832-836 Routine use of counter-immunoelectrophoresis test for detecting antibody to hepatitis B virus core antigen R. FREEMAN AND M. H. HAMBLING From the Virology

More information

Evaluation of a Novel Serotyping System for Hepatitis C Virus: Strong Correlation with Standard Genotyping Methodologies

Evaluation of a Novel Serotyping System for Hepatitis C Virus: Strong Correlation with Standard Genotyping Methodologies JOURNAL OF CLINICAL MICROBIOLOGY, Nov. 1995, p. 2978 2983 Vol. 33, No. 11 0095-1137/95/$04.00 0 Copyright 1995, American Society for Microbiology Evaluation of a Novel Serotyping System for Hepatitis C

More information

(Immunoblot) Analysis Using a Recombinant Vaccinia Virus Expression System

(Immunoblot) Analysis Using a Recombinant Vaccinia Virus Expression System JOURNAL OF CLINICAL MICROBIOLOGY, May 1993, p. 1173-1178 0095-1137/93/051173-06$02.00/0 Copyright C) 1993, American Society for Microbiology Vol. 31, No. 5 Correlation of Serum Antibody Titers against

More information

HIV-1 p24 Antigen ELISA Catalog Number:

HIV-1 p24 Antigen ELISA Catalog Number: INTENDED USE The RETRO-TEK HIV-1 p24 Antigen ELISA is supplied for research purposes only. It is not intended for use in the diagnosis or prognosis of disease, or for screening and may not be used as a

More information

Detection of IgA-class anti-hev antibody

Detection of IgA-class anti-hev antibody Detection of IgA-class anti-hev antibody Hiroaki OKAMOTO E IgA-HE IgA HEV E HEV E E E 10 E 1997 E E 1, 2 2001 E 3 HEV 4 1979 HEV 5 A B C A B C E 6, 7 E HEV E 8 11 2003 8 19 http:www.mhlw. go.jphoudou200308h0819-2.html

More information

antibody screening in patients attending a clinic for sexually

antibody screening in patients attending a clinic for sexually J. Hyg., Camb. (1984), 93, 225-232 225 Printed in Great Britain Hepatitis B core antigen synthesised in Escherichia coli: its use for antibody screening in patients attending a clinic for sexually transmitted

More information

Viral hepatitis. The word hepatitis means inflammation of the liver. There are five main types of viral hepatitis: A, B, C, D, E

Viral hepatitis. The word hepatitis means inflammation of the liver. There are five main types of viral hepatitis: A, B, C, D, E Viral hepatitis The word hepatitis means inflammation of the liver There are five main types of viral hepatitis: A, B, C, D, E Hepatitis A and E are typically caused by ingestion of contaminated food or

More information

Viral Hepatitis Diagnosis and Management

Viral Hepatitis Diagnosis and Management Viral Hepatitis Diagnosis and Management CLINICAL BACKGROUND Viral hepatitis is a relatively common disease (25 per 100,000 individuals in the United States) caused by a diverse group of hepatotropic agents

More information

Unsatisfactory Specificities and Sensitivities of Six Enzyme

Unsatisfactory Specificities and Sensitivities of Six Enzyme JOURNAL OF CLINICAL MICROBIOLOGY, Sept. 1989, p. 2067-2072 0095-1137/89/092067-06$02.00/0 Copyright C 1989, American Society for Microbiology Vol. 27, No. 9 Unsatisfactory Specificities and Sensitivities

More information

Received 21 August 2000/Returned for modification 14 December 2000/Accepted 19 March 2001

Received 21 August 2000/Returned for modification 14 December 2000/Accepted 19 March 2001 JOURNAL OF CLINICAL MICROBIOLOGY, Sept. 2001, p. 3110 3114 Vol. 39, No. 9 0095-1137/01/$04.00 0 DOI: 10.1128/JCM.39.9.3110 3114.2001 Copyright 2001, American Society for Microbiology. All Rights Reserved.

More information

The Natural Course of Chronic Hepatitis C: A Comparison Between Patients With Genotypes 1 and 2 Hepatitis C Viruses

The Natural Course of Chronic Hepatitis C: A Comparison Between Patients With Genotypes 1 and 2 Hepatitis C Viruses The Natural Course of Chronic Hepatitis C: A Comparison Between Patients With Genotypes 1 and 2 Hepatitis C Viruses MASANORI KOBAYASHI, EIJI TANAKA, TAKESHI SODEYAMA, AKIHIKO URUSHIHARA, AKIHIRO MATSUMOTO,

More information

SP.718 Special Topics at Edgerton Center: D-Lab Health: Medical Technologies for the Developing World

SP.718 Special Topics at Edgerton Center: D-Lab Health: Medical Technologies for the Developing World MIT OpenCourseWare http://ocw.mit.edu SP.718 Special Topics at Edgerton Center: D-Lab Health: Medical Technologies for the Developing World Spring 2009 For information about citing these materials or our

More information

SIV p27 ANTIGEN CAPTURE ASSAY

SIV p27 ANTIGEN CAPTURE ASSAY SIV p27 ANTIGEN CAPTURE ASSAY Enzyme Immunoassay for the detection of Simian Immunodeficiency Virus (SIV) p27 in tissue culture media Catalog #5436 and #5450 Version 6; 12/2012 ABL PRODUCTS AND SERVICES

More information

Pelagia Research Library. European Journal of Experimental Biology, 2015, 5(10):1-5

Pelagia Research Library. European Journal of Experimental Biology, 2015, 5(10):1-5 Available online at www.pelagiaresearchlibrary.com European Journal of Experimental Biology, 2015, 5(10):1-5 ISSN: 2248 9215 CODEN (USA): EJEBAU Molecular diagnosis of human immuno deficiency virus (HIV)

More information

ORIGINAL INVESTIGATION. Age-Related Response to Interferon Alfa Treatment in Women vs Men With Chronic Hepatitis C Virus Infection

ORIGINAL INVESTIGATION. Age-Related Response to Interferon Alfa Treatment in Women vs Men With Chronic Hepatitis C Virus Infection ORIGINAL INVESTIGATION Age-Related to Interferon Alfa Treatment in Women vs Men With Chronic Hepatitis C Virus Infection Jun Hayashi, MD, PhD; Yasuhiro Kishihara, MD; Kumiko Ueno, MD; Kouzaburo Yamaji,

More information

Antibodies to Treponema pallidum

Antibodies to Treponema pallidum APPLIED MICROBIOLOGY, July 1972, p. 26- Copyright 0 1972 American Society for Microbiology Vol. 24, No. 1 Printed in U.S.A. Evaluation of the Qualitative and Automated Quantitative Microhemagglutination

More information

Ali Alabbadi. Bann. Bann. Dr. Belal

Ali Alabbadi. Bann. Bann. Dr. Belal 31 Ali Alabbadi Bann Bann Dr. Belal Topics to be discussed in this sheet: Particles-to-PFU Single-step and multi-step growth cycles Multiplicity of infection (MOI) Physical measurements of virus particles

More information

Hepatitis C virus Ab ELISA Kit

Hepatitis C virus Ab ELISA Kit Hepatitis C virus Ab ELISA Kit Catalog Number KA2534 96 assays Version: 16 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay...

More information

Evaluation of the Bio-EnzaBead Test for Syphilis

Evaluation of the Bio-EnzaBead Test for Syphilis JOURNAL OF CLINICAL MICROBIOLOGY, Apr. 1987, p. 619-623 0095-1137/87/040619-05$02.00/0 Copyright 1987, American Society for Microbiology Vol. 25, No. 4 Evaluation of the Bio-EnzaBead Test for Syphilis

More information

Hepatitis A virus Ab ELISA Kit

Hepatitis A virus Ab ELISA Kit Hepatitis A virus Ab ELISA Kit Catalog Number KA0284 96 assays Version: 08 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

CEPHIA Consortium for the Evaluation and Performance of HIV Incidence Assays STANDARD OPERATING PROCEDURE

CEPHIA Consortium for the Evaluation and Performance of HIV Incidence Assays STANDARD OPERATING PROCEDURE CEPHIA Consortium for the Evaluation and Performance of HIV Incidence Assays STANDARD OPERATING PROCEDURE TITLE : SOP for (off board dilution) Less Sensitive Modified VITROS Enzyme Immunoassay CEPHIA DOCUMENT

More information

Anti-HCV Reagent Pack (STM) PIGEM1244/102.0

Anti-HCV Reagent Pack (STM) PIGEM1244/102.0 Anti-HCV Reagent Pack (STM) PIGEM1244/102.0 Symbols used» 3 SN 4 Ó e i = 'n' tests 1 j Use by/expiration date (Year Month Day) Lot Number Serial number Catalogue number Attention, see instructions for

More information

Viral Hepatitis in India: A Report from Delhi

Viral Hepatitis in India: A Report from Delhi Viral Hepatitis in India: A Report from Delhi Mohammad Irshad (Corresponding author) Clinical Biochemistry Division, Department of Laboratory Medicine All India Institute of Medical Sciences, New Delhi-110029,

More information

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Bioelisa HCV 4.0 Number: PQDx Abstract

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Bioelisa HCV 4.0 Number: PQDx Abstract WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: Bioelisa HCV 4.0 Number: PQDx 0165-060-00 Abstract Bioelisa HCV 4.0 with product codes 3000-1115 and 3000-1116, manufactured by Biokit

More information

Clinical Performance Evaluation of Four Automated Chemiluminescence Immunoassays for Hepatitis C Virus Antibody Detection

Clinical Performance Evaluation of Four Automated Chemiluminescence Immunoassays for Hepatitis C Virus Antibody Detection JOURNAL OF CLINICAL MICROBIOLOGY, Dec. 2008, p. 3919 3923 Vol. 46, No. 12 0095-1137/08/$08.00 0 doi:10.1128/jcm.01603-08 Copyright 2008, American Society for Microbiology. All Rights Reserved. Clinical

More information

Evaluation Report MHRA Four anti-hbc assays. 60 (Free to NHS) MHRA Report number MHRA Evaluation Report. Crown Copyright.

Evaluation Report MHRA Four anti-hbc assays. 60 (Free to NHS) MHRA Report number MHRA Evaluation Report. Crown Copyright. November 2003 NUMBER Evaluation Report MHRA 03136 Four anti-hbc assays MHRA Evaluation Report MHRA Report number 03136 Crown Copyright 60 (Free to NHS) WHAT YOU CAN EXPECT FROM MHRA EVALUATION REPORTS

More information

Research Article Decision on conducting HCV Immunoblot and HCV Viral Load Tests Dependent upon the Result of the Screening Tests

Research Article Decision on conducting HCV Immunoblot and HCV Viral Load Tests Dependent upon the Result of the Screening Tests IBIMA Publishing Journal of Virology & Microbiology http://www.ibimapublishing.com/journals/jvm/jvm.html Vol. 2013 (2013), Article ID 332501, 7 pages DOI: 10.5171/2013.332501 Research Article Decision

More information

Influenza A IgG ELISA

Influenza A IgG ELISA Influenza A IgG ELISA For the qualitative determination of IgG-class antibodies against Influenza A virus in human serum or plasma (citrate, heparin). For Research Use Only. Not For Use In Diagnostic Procedures.

More information

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Enzygnost HBsAg 6.0 WHO reference number: PQDx

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Enzygnost HBsAg 6.0 WHO reference number: PQDx WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT Product: Enzygnost HBsAg 6.0 WHO reference number: PQDx 0173-064-00 Enzygnost HBsAg 6.0 with product codes OPFM03, OPFM05, OPFM07(Q)

More information

Past and Present Hepatitis G Virus Infections in Areas Where Hepatitis C is Highly Endemic and Those Where It Is Not Endemic

Past and Present Hepatitis G Virus Infections in Areas Where Hepatitis C is Highly Endemic and Those Where It Is Not Endemic JOURNAL OF CLINICAL MICROBIOLOGY, Jan. 1998, p. 110 114 Vol. 36, No. 1 0095-1137/98/$04.00 0 Copyright 1998, American Society for Microbiology Past and Present Hepatitis G Virus Infections in Areas Where

More information

ANTIGEN SANDWICH ELISA PREDICTS RT-PCR DETECTION OF DENGUE VIRUS GENOME IN INFECTED CULTURE FLUIDS OF AEDES ALBOPICTUS C6/36 CELLS

ANTIGEN SANDWICH ELISA PREDICTS RT-PCR DETECTION OF DENGUE VIRUS GENOME IN INFECTED CULTURE FLUIDS OF AEDES ALBOPICTUS C6/36 CELLS ANTIGEN SANDWICH ELISA PREDICTS RT-PCR DETECTION OF DENGUE VIRUS GENOME IN INFECTED CULTURE FLUIDS OF AEDES ALBOPICTUS C6/36 CELLS Corazon C Buerano 1,2, Filipinas F Natividad 2, Rodolfo C Contreras 3,

More information

Dengue Virus IgM Elisa kit

Dengue Virus IgM Elisa kit DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

HIV-1/2 Ab ELISA Kit. Catalog Number KA assays Version: 12. Intended for research use only.

HIV-1/2 Ab ELISA Kit. Catalog Number KA assays Version: 12. Intended for research use only. HIV-1/2 Ab ELISA Kit Catalog Number KA0292 96 assays Version: 12 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle of the Assay...

More information

L\\\\\\1 V\\ High dose interferon treatment in chronic hepatitis C. Group A. Group B. Dosage. Treatment period

L\\\\\\1 V\\ High dose interferon treatment in chronic hepatitis C. Group A. Group B. Dosage. Treatment period SI 14 Gut 1993; supplement: SI 14-S118 Institute of Medical Science, School ofmedicine, St Marianna University, Japan S Iino Correspondence to: Dr S Iino, Institute of Medical Science, School of Medicine,

More information

Research Communication

Research Communication IUBMB Life, 63(6): 430 434, June 2011 Research Communication Diagnosis of Hepatitis C Virus Infection by Enzyme-linked Immunosorbent Assay and Reverse Transcriptase-Nested Polymerase Chain Reaction: A

More information

E E Hepatitis E SARS 29, Lancet. E A B Enterically-Transmitted Non-A, Hepatitis E. Virus HEV nm. 1.35g/cm s ALT AST HEV HEV

E E Hepatitis E SARS 29, Lancet. E A B Enterically-Transmitted Non-A, Hepatitis E. Virus HEV nm. 1.35g/cm s ALT AST HEV HEV 7850 2004 Hepatitis E Tian-Cheng LI Naokazu TAKEDA Tatsuo MIYAMURA SARS 8 Lancet E E E Hepatitis E VirusHEV E E HEV HEV E 1955 29,000 E E A A B Enterically-Transmitted Non-A, Non-B Hepatitis 1983 Balayan

More information

Serum Amyloid A ELISA

Serum Amyloid A ELISA Serum Amyloid A ELISA For the quantitative determination of serum amyloid A (SAA) in serum plasma For Research use Only. Not for Use in Diagnostic Procedures Please see Appendix A for Reference Serum information

More information

RG12T. For In Vitro Diagnostic Use. Passive Particle-Agglutination Test for Detection of Antibodies to HTLV-

RG12T. For In Vitro Diagnostic Use. Passive Particle-Agglutination Test for Detection of Antibodies to HTLV- RG12T Read this insert carefully before performing the assay and keep for future reference. The reliability of assay procedures other than those described in this package insert cannot be guaranteed. For

More information

HEALTH SCIENCES DIVISION

HEALTH SCIENCES DIVISION HEALTH SCIENCES DIVISION HEPATITIS E VIRUS INFECTION DIAGNOSED BY SEROLOGY: A REPORT OF CASES AT THE SAN LAZARO HOSPITAL, MANILA NINA GLORIANI-BARZAGA 1 M.D., Ph.D. ARTURO CABANBAN 2, M.D. ROBERT ROSS

More information

See external label 2 C-8 C Σ=96 tests Cat # 3122Z MICROWELL ELISA THYROID STIMULATING HORMONE (TSH) ENZYME IMMUNOASSAY TEST KIT TSH.

See external label 2 C-8 C Σ=96 tests Cat # 3122Z MICROWELL ELISA THYROID STIMULATING HORMONE (TSH) ENZYME IMMUNOASSAY TEST KIT TSH. DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

Serological Markers in Chimpanzees

Serological Markers in Chimpanzees INFECTION AND IMMUNITY, May 1979, p. 352-356 Vol. 24, No. 2 0019-9567/79/05-0352/05$02.00/0 Hepatitis B e-antigen and Its Correlation with Other Serological Markers in Chimpanzees CHUNG-MEI LING,* ISA

More information

Items Contents 1. Intended use 2. Summary and Test Explanation 3. Test Description 4. Description of Materials Provided & Product Code System 4.

Items Contents 1. Intended use 2. Summary and Test Explanation 3. Test Description 4. Description of Materials Provided & Product Code System 4. Items Contents 1. Intended use 2. Summary and Test Explanation 3. Test Description 4. Description of Materials Provided & Product Code System 4.1 Storage Conditions and Stability of Kit and Components

More information

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: Alere HIV Combo WHO reference number: PQDx

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: Alere HIV Combo WHO reference number: PQDx WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT Product: Alere HIV Combo WHO reference number: PQDx 0243-013-00 Alere HIV Combo with product codes 7D2842, 7D2843, 7D2843SET manufactured by Alere

More information

Ribavirin in the treatment of chronic hepatitis C unresponsive to alfa interferon

Ribavirin in the treatment of chronic hepatitis C unresponsive to alfa interferon 408 Journal of Hepatology, 1993; 19:408-412 1993 Elsevier Scientific Publishers Ireland Ltd, All rights reserved. 0168-8278/93/$06.00 HEPAT 01452 Ribavirin in the treatment of chronic hepatitis C unresponsive

More information

Toxoplasma gondii IgM (Toxo IgM)

Toxoplasma gondii IgM (Toxo IgM) DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com

More information

STEVE NISHIMURA FALL 1990 HEPATITIS C. Introduction

STEVE NISHIMURA FALL 1990 HEPATITIS C. Introduction STEVE NISHIMURA FALL 1990 HEPATITIS C Introduction With the recent identification and sequencing of the viral genome of the hepatitis C virus (HCV) and the subsequent development of an ELISA assay, a wealth

More information

INSTRUCTION FOR USE EIA-ANTI-HDV

INSTRUCTION FOR USE EIA-ANTI-HDV GWB-HDVIGG 96 INSTRUCTION FOR USE EIA-ANTI-HDV ENZYME IMMUNOASSAY FOR THE DETECTION OF TOTAL ANTIBODIES TO HEPATITIS DELTA VIRUS Page 1 of 10 Table of contents I. Intended use. 3 II. Contents of the EIA-ANTI-HDV.....

More information

H. pylori Antigen ELISA Kit

H. pylori Antigen ELISA Kit H. pylori Antigen ELISA Kit Catalog Number KA3142 96 assays Version: 04 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle of

More information

EBV-EA IgG. Cat # 1415Z. EBV -EA IgG ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

EBV-EA IgG. Cat # 1415Z. EBV -EA IgG ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external

More information

STAT1 (ps727) (Human/Mouse) ELISA Kit

STAT1 (ps727) (Human/Mouse) ELISA Kit STAT1 (ps727) (Human/Mouse) ELISA Kit Catalog Number KA2171 96 assays Version: 01 Intended for research use only www.abnova.com I. INTRODUCTION STAT1 (ps727) (Human/Mouse) ELISA (Enzyme-Linked Immunosorbent

More information

Human HIV (1+2) antigen&antibody ELISA Kit

Human HIV (1+2) antigen&antibody ELISA Kit Human HIV (1+2) antigen&antibody ELISA Kit Catalog Number. CSB-E18042h For the qualitative determination of human HIV (1+2) antibody and P24 antigen concentrations in serum, plasma. This package insert

More information

Innovation in Diagnostics. ToRCH. A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES

Innovation in Diagnostics. ToRCH. A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES Innovation in Diagnostics ToRCH A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES EN TOXOPLASMOSIS Toxoplasmosis is a parasitic disease caused by with the obligate intracellular

More information

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Enzygnost HIV Integral 4 WHO reference number: PQDx

WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Enzygnost HIV Integral 4 WHO reference number: PQDx PQDx 0214-064-00 WHO PQDx PR April/2016, version 3.0 WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT Product: Enzygnost HIV Integral 4 WHO reference number: PQDx 0214-064-00 Enzygnost

More information

Who to Treat? Consider biopsy Treat. > 2 ULN Treat Treat Treat Treat CIRRHOTIC PATIENTS Compensated Treat HBV DNA detectable treat

Who to Treat? Consider biopsy Treat. > 2 ULN Treat Treat Treat Treat CIRRHOTIC PATIENTS Compensated Treat HBV DNA detectable treat Who to Treat? Parameter AASLD US Algorithm EASL APASL HBV DNA CRITERIA HBeAg+ >, IU/mL > 2, IU/mL > 2, IU/mL >, IU/mL HBeAg- > 2, IU/mL > 2, IU/mL > 2, IU/mL > 2, IU/mL ALT CRITERIA PNALT 1-2 ULN Monitor

More information

CHAPTER 4 IMMUNOLOGICAL TECHNIQUES

CHAPTER 4 IMMUNOLOGICAL TECHNIQUES CHAPTER 4 IMMUNOLOGICAL TECHNIQUES Nitroblue Tetrazolium Chloride (NBT) Reduction test NBT reduction test was evaluated by employing the method described by Hudson and Hay,1989 based upon principle that

More information

Infectious Disease Testing. ULTRA Product Line. Safety is not a Matter of Chance

Infectious Disease Testing. ULTRA Product Line. Safety is not a Matter of Chance Infectious Disease Testing ULTRA Product Line Safety is not a Matter of Chance ULTRA Product Line The best answer for HBV, HCV and HIV screening: a global automated solution for safe results. Monolisa

More information

Herpes Simplex Virus 2 IgM HSV 2 IgM

Herpes Simplex Virus 2 IgM HSV 2 IgM DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and 116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com

More information

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man Coulter HIV-1 p24 ELISA May 21, 2004

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man Coulter HIV-1 p24 ELISA May 21, 2004 Coulter HIV p24 1. PRINCIPLE The Human Immunodeficiency Virus Type 1 (HIV-1) is recognized as the etiologic agent of acquired immunodeficiency syndrome (AIDS). The virus is transmitted by sexual contact,

More information

Markers of Hepatitis C and B Virus Infections among Blood Donors in Ho Chi Minh City and Hanoi, Vietnam

Markers of Hepatitis C and B Virus Infections among Blood Donors in Ho Chi Minh City and Hanoi, Vietnam CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, July 1994, p. 413-418 Vol. 1, No. 4 1071-412X/94/$04.00+0 Copyright X) 1994, American Society for Microbiology Markers of Hepatitis C and B Virus Infections

More information

Rat TSH ELISA KIT. Please, read this instruction carefully before use.

Rat TSH ELISA KIT. Please, read this instruction carefully before use. Rat TSH ELISA KIT Research Reagent Please, read this instruction carefully before use. This is an ELISA (Enzyme Linked ImmunoSorbent Assay) kit for measurement of rat TSH (thyroid-stimulating hormone)

More information

Rubella Latex Agglutination Test

Rubella Latex Agglutination Test Rubella Latex Agglutination Test Cat. No.:DLAT1088 Pkg.Size:30T Intended use The Rubella Latex Agglutination Test is a rapid latex particle agglutination test for the qualitative and semi-quantitative

More information

colorimetric sandwich ELISA kit datasheet

colorimetric sandwich ELISA kit datasheet colorimetric sandwich ELISA kit datasheet For the quantitative detection of human IL5 in serum, plasma, cell culture supernatants and urine. general information Catalogue Number Product Name Species cross-reactivity

More information

Received 30 July 2011/Returned for modification 1 September 2011/Accepted 14 September 2011

Received 30 July 2011/Returned for modification 1 September 2011/Accepted 14 September 2011 JOURNAL OF CLINICAL MICROBIOLOGY, Dec. 2011, p. 4089 4093 Vol. 49, No. 12 0095-1137/11/$12.00 doi:10.1128/jcm.05292-11 Copyright 2011, American Society for Microbiology. All Rights Reserved. Comparison

More information

Testing for Viral Hepatitis A Practice Parameter

Testing for Viral Hepatitis A Practice Parameter AJCP / TESTING FOR VIRAL HEPATITIS Testing for Viral Hepatitis A Practice Parameter Ronald A. Sacher, MD, FRCPC, 1 Stephen M. Peters, PhD, FAAM, 2 and John A. Bryan, MD 3 Key Words: Viral hepatitis; Laboratory

More information

Apolipoprotein A-1 ELISA

Apolipoprotein A-1 ELISA Apolipoprotein A-1 ELISA For the quantitative determination of apolipoprotein A1 in serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures. Please read carefully due to Critical

More information

Mycoplasma pneumoniae IgG ELISA Kit

Mycoplasma pneumoniae IgG ELISA Kit Mycoplasma pneumoniae IgG ELISA Kit Catalog Number KA2260 96 assays Version: 01 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

HIV-1 p24 Antigen ELISA 2.0 Catalog Number:

HIV-1 p24 Antigen ELISA 2.0 Catalog Number: INTENDED USE The RETRO-TEK HIV-1 p24 Antigen ELISA 2.0 is an enzyme linked immunoassay used to detect Human Immunodeficiency Virus Type 1 (HIV-1) p24 antigen in cell culture media. It can be used to monitor

More information