Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging

Size: px
Start display at page:

Download "Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging"

Transcription

1 ORIGINAL ARTICLE Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging Kurtis G. Lightheart, a Jeryl D. English, b Chung H. Kau, c Sercan Akyalcin, d Harry I. Bussa, Jr, e Kathleen R. McGrory, f and Kevin J. McGrory f Houston, Tex, and Birmingham, Ala Introduction: The purpose of this research was to determine the accuracy of digital models generated by conebeam computed tomography and compare it with that of OrthoCAD models (Cadent, Carlstadt, NJ) for orthodontic diagnosis and treatment planning by using surface area analysis. Materials: Two sets of maxillary and mandibular digital models of 30 subjects were obtained. The models were made from impressions scanned with OrthoCAD and by conversion of related cone-beam computed tomography files. Each patient s matched pairs of maxillary and mandibular models were superimposed by using a software program and a best-fit algorithm; surface-to-surface analysis was then performed. The average linear differences between the 2 files at all points on the surfaces were measured, and tolerance levels of 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm were set to determine the surface correlation amounts between the 2 files. Additionally, 6 linear measurements from predetermined landmarks were also measured and analyzed. Results: The average maxillary model linear difference was 0.28 to 0.60 mm, whereas the average mandibular model linear difference ranged between 0.34 and 0.61 mm. Greater than a 90% surface correlation was obtained on average at 1.00 mm in the maxillary models and at 1.25 mm in the mandibular models. The mean differences obtained from the linear measurements of the maxillary and mandibular models were and mm, respectively. Conclusions: Surface-to-surface analysis of OrthoCAD and digital models generated by cone-beam computed tomography pointed to a fair overlap between the protocols. The accuracy of digital models generated by cone-beam computed tomography is adequate for initial diagnosis and treatment planning in orthodontics. (Am J Orthod Dentofacial Orthop 2012;141:686-93) Acomprehensive and accurate treatment plan can be possible only by a thorough evaluation of dental models, intraoral and extraoral photographs, and panoramic and cephalometric images. 1 a Resident, Department of Orthodontics, School of Dentistry, University of Texas Health Science Center, Houston. b Chair and professor, Department of Orthodontics, School of Dentistry, University of Texas Health Science Center, Houston. c Chair and professor, Department of Orthodontics, School of Dentistry, University of Alabama, Birmingham. d Assistant professor, Department of Orthodontics, School of Dentistry, University of Texas Health Science Center, Houston. e Clinical professor, Department of Orthodontics, School of Dentistry, University of Texas Health Science Center, Houston. f Clinical assistant professor, Department of Orthodontics, School of Dentistry, University of Texas Health Science Center, Houston. The authors report no commercial, proprietary, or financial interest in the products or companies described in this article. Reprint requests to: Sercan Akyalcin, University of Texas Health Science Center, School of Dentistry, Department of Orthodontics, 6516 MD Anderson Blvd, Suite 371, Houston, TX 77030; , sercan.akyalcin@uth.tmc.edu. Submitted, July 2011; revised and accepted, December /$36.00 Copyright Ó 2012 by the American Association of Orthodontists. doi: /j.ajodo Recent advances in digital technology have vastly improved the diagnostic phase of orthodontic treatment, and analog records have quickly been replaced by digital formats. 2,3 The digital alternative offers a great advantage when contemplating the storage space required for traditional plaster models. Digital models can be stored virtually instead of physically, thus reducing the need for storage space along with reducing the costs involved. 4-8 Advances in technology and software have allowed digital models to be generated from cone-beam computerized tomography (CBCT) scans. Acquired digital imaging and communications in medicine (DICOM) files captured by the orthodontist can be uploaded to a company s Web site, and a digital model can be obtained from the file. Once the model is generated by the proprietary software, the orthodontist can download, view, manipulate, and evaluate the models using software provided by the company. This technology allows for all anatomic structures from the CBCT image captured during the scan to be viewed. For example, 686

2 Lightheart et al 687 Fig 1. Superimposition of OrthoCAD and CBCT-generated models. roots of teeth, temporomandibular joint structures, impacted teeth, and bone levels are all visible. The practitioner can view, evaluate, and manipulate the models and bases alone without any accompanying bony structures. 9 However, the disadvantages to this approach are the lack of gingival tissues in the digital models and concern about possible unnecessary overexposure to radiation. Cone-beam technology is at the forefront of digital radiography, and generating digital models for diagnostic purposes from this information is a potential advancement that will help in the digitization of the orthodontic office. 10 However, digital models offer an advantage over plaster models only if they are proven to be as accurate for the diagnostic phase of treatment. A recent study showed that space analysis on OrthoCAD digital models (Cadent, Carlstadt, NJ) is clinically acceptable and reproducible when compared with traditional plaster study model analyses. 11 Fleming et al 12 concluded that, overall, the absolute mean differences between direct and indirect measurements on plaster and digital models were minor and clinically insignificant. The accuracy from linear measurements obtained from study casts generated by CBCT was also considered adequate for initial diagnosis and treatment planning in orthodontics, as shown elsewhere. 13,14 Validation of surface characteristics of digital models might particularly be important when considering various appliance designs used in clinical applications. The purpose of this study, therefore, was to examine the accuracy of digital models generated by CBCT compared with OrthoCAD digital models by using surface area shell analysis of stereolithography files. MATERIAL AND METHODS Thirty subjects were included in the study. Two sets of maxillary and mandibular digital models were obtained from them by scanning impressions with OrthoCAD and conversion of their CBCT files with Anatomage software (Anatomage, San Jose, Calif). All subjects were in the permanent dentition and had their impressions and baseline CBCT images obtained at the time of initial records for diagnosis and treatment planning at the Department of Orthodontics, School of Dentistry, University of Texas Health Science Center at Houston. A Galileos Comfort x-ray unit (Sirona Dental Systems, Bensheim, Germany) was used to capture the CBCT images. With 200 exposures from a 14-second cycle in a 220 segment, a high level of detail from a cm volume capture image, and a large dental volume ranging from the tip of the nose to the chin and the mandibular joints, the cone-shaped conebeam radiation beams of the Galileos x-ray detector allowed for small-region close-up views at double the detail without an additional scan. Image reconstruction time was approximately 4.5 minutes, and voxel size was 0.30 mm. The CBCT images were uploaded to Anatomage and digitally reformatted to include volume rendering and image conversion. After this conversion, the 3- dimensional digital models were available for downloading from the server. American Journal of Orthodontics and Dentofacial Orthopedics June 2012 Vol 141 Issue 6

3 688 Lightheart et al Fig 2. Surface correlation analysis at 6 tolerance levels: a, 0.25 mm; b, 0.5 mm; c, 0.75 mm; d, 1.00 mm; e, 1.25 mm; f, 1.5 mm. The OrthoCAD models were obtained from the maxillary and mandibular impressions taken with Identic alginate (Dux Dental, Oxnard, Calif), along with bite registrations taken with polyvinylsiloxane material (Blue Moose, Parkell, Edgewood, NY). After disinfection, the records were placed in sealed plastic bags and mailed to OrthoCAD. Once received, poured, and digitized, the OrthoCAD digital models were available for download from the company s Web site. Stereolithography files were obtained from both the CBCT and the scanned impressions. This is a file format native to the stereolithography computer-aided design software created by 3D Systems (Rockhill, SC). In this study, Stereolithography files were required for both digital formats because the surface shapes and volumes were analyzed. Stereolithography files or shells were opened in the Rapidform software program (Inus Technology, Seoul, South Korea) for surface-to-surface analysis. In Rapidform, the stereolithography files from the CBCT were cropped to remove hard tissue, leaving as much tooth structure as possible above the alveolar bone crest. The OrthoCAD stereolithography files were also cropped to remove as much gingival tissue as possible. The cropped stereolithography files from both the CBCT scans and OrthoCAD were then superimposed, June 2012 Vol 141 Issue 6 American Journal of Orthodontics and Dentofacial Orthopedics

4 Lightheart et al 689 Fig 3. Linear measurements on digital models. and the Rapidform software obtained a best-fit from the 2 files (Fig 1). Once superimposed, a surfaceto-surface analysis was performed to compare the accuracy of the CBCT-generated digital models with the OrthoCAD digital models. This analysis averaged the linear differences between the 2 files at all points on the surfaces. For this study, tolerance levels were set to visualize the discrepancies between the 2 files that fell outside the set tolerance levels. The tolerance levels used in the study were 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm (Fig 2). During the visualization process, a linear difference less than the tolerance level appeared black on the superimposed image, and a linear difference greater than the tolerance level appeared as a color on a scale depending on the amount of the difference. Thus, black on the scale indicated that the linear difference fell within the tolerance range, and the colored regions on the scale indicated that the linear difference fell outside the tolerance level; blue was the most correlated, and red was the least. Mean differences at each tolerance level were recorded and compiled. In addition, the total surface areas corresponding to the tolerance levels were recorded as percentages. Six linear measurements (Fig 3) were made on each maxillary and mandibular model. The digital models by Anatomage were measured by using the proprietary software, InVivoDental, and the OrthoCAD models were measured by using the OrthoCAD proprietary software, OrthoCAD. Definitions of the linear measurements are summarized in Table I. Statistical analysis Intraclass correlation coefficients were calculated for the measurements obtained from maxillary and mandibular OrthoCAD and CBCT-generated models to test the reliability of the CBCT-generated models. IBM SPSS Statistics (version 19; IBM, Armonk, NY) was used to analyze the data. To further graphically display the levels of error between the 2 techniques, Bland-Altman analysis was performed by using XLSTAT Mac (version 2011; Addinsoft, New York, NY). RESULTS The average maxillary linear differences between the CBCT-generated and the OrthoCAD models were 0.28 to 0.60 mm, with a median of 0.36 mm. The average mandibular linear difference range between the CBCTgenerated and the OrthoCAD models was 0.34 to 0.61 mm, with a median of 0.44 mm (Table II). The results of the surface overlap for the maxillary and mandibular models in each tolerance level are presented in Table III. The average overlap of the surfaces for the maxillary models ranged from 45.76% at 0.25 mm of tolerance to 99.59% at 1.50 mm of tolerance. The average for the American Journal of Orthodontics and Dentofacial Orthopedics June 2012 Vol 141 Issue 6

5 690 Lightheart et al Table I. Definitions of linear measurements on the digital casts Maxillary cast measurements UR4-UL4 UR5-UL5 UR4-ML UR5-ML UL4-ML UL5-ML Mandibular cast measurements LR4-LL4 LR5-LL5 LR4-ML LR5-ML LL4-ML LL5-ML Buccal cusp tip of the upper right first premolar to the same point on the upper left first premolar Buccal cusp tip of the upper right second premolar to the same point on the upper left second premolar Buccal cusp tip of the upper right first premolar to the maxillary midline Buccal cusp tip of the upper right second premolar to the maxillary midline Buccal cusp tip of the upper left first premolar to the maxillary midline Buccal cusp tip of the upper left second premolar to the maxillary midline Buccal cusp tip of the lower right first premolar to the same point on the lower left first premolar Buccal cusp tip of the lower right second premolar to the same point on the lower left second premolar Buccal cusp tip of the lower right first premolar to the mandibular midline Buccal cusp tip of the lower right second premolar to mandibular midline Buccal cusp tip of the lower left first premolar to the mandibular midline Buccal cusp tip of the lower left second premolar to mandibular midline Table II. Maxillary and mandibular surface-to-surface analysis of CBCT-generated and OrthoCAD model overlays Maxillary casts Average distance (mm) Mandibular casts mandibular models ranged from 42.51% at 0.25 mm to 94.85% at 1.50 mm. Table IV displays the means and standard deviations of the linear measurements on both the OrthoCAD and the CBCT-generated models. These results indicate strong agreement (0.87 #single measure ICCs #0.99) between the 2 methods based on the 12 linear measurements for the maxillary and mandibular pairs. Figures 4 and 5 show the Bland-Altman plots for the maxillary and mandibular pairs. Both figures graphically demonstrate small systematic errors between the 2 techniques. In the maxilla, the results indicated that the mean difference between the CBCT-generated and the OrthoCAD models was mm. In the mandible, the mean difference between the CBCT-generated and the OrthoCAD models was mm. Differences within a mean 6 2 SD are small and not clinically important. Therefore, our results suggest that the 2 methods can be used interchangeably. DISCUSSION The use of CBCT technology in the dental office allows for the reproduction of multiple images in all 3 planes of the space and evaluating our patients in 3 dimensions. Acquisition of regular study models from SD Average distance (mm) Low High Median SD DICOM files will, however, greatly enhance the use of CBCT images in daily practice and reduce the need for space and the relative costs. Furthermore, CBCTgenerated models do not depend on impressions and can be reproduced at any time by using the baseline DI- COM images. This method might, therefore, offer a valid alternative to all other commercially available digital model systems. Recent studies have indicated that reliable measurements for tooth size, arch length, space analysis, overjet, overbite, and the Bolton ratio can be obtained with digital models. 4,11,13-19 It was also recently shown that CBCT-generated digital models were as accurate as digital models. 13,14 However, CBCT provides a valid alternative to other digital model systems as long as there is also reliable surface matching. The surface analyses of the OrthoCAD and CBCTgenerated digital models in this study demonstrated that the average linear differences between their surface areas varied between 0.28 and 0.61 mm. Although this might be considered promising, there is clearly a need for improvement in generating digital models from CBCT image scans. Our tolerance-level averages showed that a 90% overlap correlation did not appear until a 1.0 to 1.25-mm alteration on the surface area was reached. A tolerance level of 1.25 mm difference can be problematic, considering the precision of clinical orthodontic applications such as indirect bonding. However, correlation averages are derived from the whole surface area. Ortho- CAD and CBCT-generated models differ from each other significantly, particularly in the gingival areas. Although care was taken when the stereolithography files from the CBCT scans were cropped to leave as much tooth structure as possible above the alveolar bone crest, the remaining differences might have negatively affected the overlap correlation averages within the limitations of our study. These numbers might increase if the June 2012 Vol 141 Issue 6 American Journal of Orthodontics and Dentofacial Orthopedics

6 Lightheart et al 691 Table III. Overlap amounts for maxillary and mandibular casts at the various tolerance levels Maxillary casts Mandibular casts Low High Average Low High Average 0.25 mm 34.29% 60.49% 45.76% 36.02% 60.01% 42.51% 0.50 mm 64.51% 89.93% 72.83% 65.75% 87.42% 68.82% 0.75 mm 83.28% 98.49% 85.49% 79.59% 95.96% 80.57% 1.00 mm 92.24% 99.69% 92.07% 85.11% 98.41% 86.49% 1.25 mm 95.31% 99.99% 96.72% 89.75% 99.49% 91.19% 1.50 mm 98.47% 99.99% 99.59% 93.72% 99.95% 94.85% Table IV. Means and standard deviations of the linear measurements on the paired OrthoCad and CBCT-generated models with single-measure intraclass correlation coefficients (ICC) Maxillary pairs Mandibular pairs OrthoCad models CBCT-generated models OrthoCad models CBCT-generated models Variable (mm) Mean SD Mean SD ICC Variable (mm) Mean SD Mean SD ICC UR4-UL LR4-LL UR5-UL LR5-LL UR4-ML LR4-ML UR5-ML LR5-ML UL4-ML LL4-ML UL5-ML LL5-ML gingiva was taken out of the evaluation so that it would be purely a tooth-to-tooth comparison. This might explain why the linear measurements, which are related more to tooth structure, showed a stronger agreement between the 2 techniques. Therefore, tasks that are related to gingival surface areas eg, design of a vacuum-formed appliance should not be performed on CBCT-generated models. Previous research studies comparing agreement between linear measurements made with OrthoCAD-derived models and conventional models have demonstrated acceptable reproducibility and agreement. 11,12,15,16 However, it has also been reported that complicated measurements eg, available space in the mandible, 4 the irregularity index, 17 and maxillary arch length 18 might have significant mean differences between the classic and digital models. All real-world measurements have some degree of error. Possible causes of statistical differences between impression-derived casts and digital models include handling techniques and problems related to different impression materials. 20 Digital models might be adequate but not yet a panacea. 21 In our study, we aimed to document the differences between OrthoCAD and CBCT-generated models for both linear measurements and surface areas. The rationale behind this was to investigate whether CBCT-generated models could be used instead of OrthoCAD digital models. Our results clearly indicate that OrthoCAD and CBCT-generated models have similar values for diagnostic purposes and linear measurements. However, concerns persist in relation to assessment of surface areas; this requires further investigation. CBCT-based diagnostic tasks depend on the accuracy of dental measurements. Baumgaertel et al 22 examined the reliability of dental measurements made on CBCT reconstructions using dry human skulls. Their results indicated that dental measurements from CBCT volumes could safely be used for quantitative analysis. Although they found a slight underestimation of the actual value, this became statistically significant only when several measurements were combined. Similarly, dental measurements of CBCT volumes showed good reliability in determining the diameter of unerupted teeth 23 and tooth and root lengths. 24 Furthermore, Damstra et al 25 concluded that measurements on 3-dimensional surface models of 0.25 to 0.40 voxel size data sets are accurate compared with direct caliper measurements. The Galileos Comfort x-ray imaging unit used in this study has a resolution between 0.15 and 0.30, which is acceptable according to the suggested range. However, a decrease in voxel size might enhance the quality of the scans and result in better correlation of CBCT-generated models with the classic and digital models. Therefore, American Journal of Orthodontics and Dentofacial Orthopedics June 2012 Vol 141 Issue 6

7 692 Lightheart et al Fig 4. Bland-Altman plot for maxillary linear measurements. Fig 5. Bland-Altman plot for mandibular linear measurements. accuracy of CBCT-generated models obtained by other commercially available scanners with smaller voxel sizes might be worthwhile to investigate in the future. One practical limitation with the use of CBCT images to generate dental models might relate to the radiation dose absorbed by the patient, which we hope can be reduced to a negligible amount in the next generation of cone-beam scanners. Until then, digital plaster casts generated by CBCT imaging should not be obtained from every patient. CONCLUSIONS Within the limitations of this study, overlap amounts between the surface areas of the OrthoCAD and the June 2012 Vol 141 Issue 6 American Journal of Orthodontics and Dentofacial Orthopedics

8 Lightheart et al 693 CBCT-generated digital models were fair. However, the linear measurements obtained from the CBCT images indicate a high level of accuracy when compared with the OrthoCAD models. Therefore, CBCT-generated digital models can be considered adequate in the early planning phase of orthodontic treatment. REFERENCES 1. Han UK, Vig KW, Weintraub JA, Vig PS, Kowalski CJ. Consistency of orthodontic treatment decisions relative to diagnostic records. Am J Orthod Dentofacial Orthop 1991;100: Garino F, Garino B. From digital casts to digital occlusal set-up: an enhanced diagnostic tool. World J Orthod 2003;4: Garino B, Garino F. Comparison of dental arch measurements between stone and digital casts. World J Orthod 2002;3: Quimby ML, Vig KW, Rashid RG, Firestone AR. The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod 2004;74: Rheude B, Sadowsky PL, Ferriera A, Jacobson A. An evaluation of the use of digital study models in orthodontic diagnosis and treatment planning. Angle Orthod 2005;75: Bell A, Ayoub AF, Siebert P. Assessment of the accuracy of a threedimensional imaging system for archiving dental study models. J Orthod 2003;30: Joffe L. OrthoCAD: digital models for a digital era. J Orthod 2004; 31: Mayers M, Firestone AR, Rashid R, Vig KWL. Comparison of peer assessment rating (PAR) index scores of plaster and computer-based digital models. Am J Orthod Dentofacial Orthop 2005;128: Mah J. The evolution of digital study models. J Clin Orthod 2007; 9: Kau CH, Richmond S, Palomo JM, Hans MG. Three-dimensional cone beam computerized tomography in orthodontics. J Orthod 2005;32: Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ. Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofacial Orthop 2009;136:16.e1-4; discussion, Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 2011;14: Kau CH, Littlefield J, Rainy N, Nguyen JT, Creed B. Evaluation of CBCT digital models and traditional models using the Little s index. Angle Orthod 2010;80: Creed B, Kau CH, English J, Xia JJ, Lee RP. A comparison of the accuracy of linear measurements obtained from cone beam computerized tomography images and digital models. Semin Orthod 2011;17: Santoro M, Galkin S, Teredesai M, Nicolay O, Cangialosi TJ. A comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop 2003;124: Goonewardene RW, Goonewardene MS, Razza JM, Murray K. Accuracy and validity of space analysis and irregularity index measurements using digital models. Aust Orthod J 2008;24: Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW. Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofacial Orthop 2006;129: Mullen SR, Martin CA, Ngan P, Gladwin M. Accuracy of space analysis with emodels and plaster models. Am J Orthod Dentofacial Orthop 2007;132: Horton HM, Miller JR, Gaillard PR, Larson BE. Technique comparison for efficient orthodontic tooth measurements using digital models. Angle Orthod 2010;80: Torassian G, Kau CH, English JD, Powers J, Bussa HI, Marie Salas-Lopez A, et al. Digital models vs plaster models using alginate and alginate substitute materials. Angle Orthod 2010;80: Brusco N, Andreetto M, Lucchese L, Carmignato S, Cortelazzo GM. Metrological validation for 3D modeling of dental plaster casts. Med Eng Phys 2007;29: Baumgaertel S, Palomo JM, Palomo L, Hans MG. Reliability and accuracy of cone-beam computed tomography dental measurements. Am J Orthod Dentofacial Orthop 2009;136: Nguyen E, Boychuk D, Orellana M. Accuracy of cone-beam computed tomography in predicting the diameter of unerupted teeth. Am J Orthod Dentofacial Orthop 2011;140:e Sherrard JF, Rossouw PE, Benson BW, Carrillo R, Buschang PH. Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs. Am J Orthod Dentofacial Orthop 2010;137(4 Suppl):S Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y. Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop 2010;137:16.e1-6. American Journal of Orthodontics and Dentofacial Orthopedics June 2012 Vol 141 Issue 6

Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts

Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts ORIGINAL ARTICLE Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts Peter A. Costalos, a Keivan Sarraf, b Thomas J. Cangialosi,

More information

Computer technology is expanding to include

Computer technology is expanding to include TECHNO BYTES Comparison of measurements made on digital and plaster models Margherita Santoro, DDS, MA, a Scott Galkin, DMD, b Monica Teredesai, DMD, c Olivier F. Nicolay, DDS, MS, d and Thomas J. Cangialosi,

More information

The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models

The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models Ahmad L Maroua et al ORIGINAL RESEARCH 10.5005/jp-journals-10024-1844 The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models 1 Ahmad L Maroua, 2 Mowaffak Ajaj, 3 Mohammad

More information

Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity

Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity European Journal of Orthodontics 32 (2010) 589 595 doi:10.1093/ejo/cjp159 Advance Access Publication 17 February 2010 The Author 2010. Published by Oxford University Press on behalf of the European Orthodontic

More information

TREATMENT PLANNING WITH DIGITAL ORTHODONTIC MODELS Jean-Marc Retrouvey, Liliya Nicholcheva, Nathan Light

TREATMENT PLANNING WITH DIGITAL ORTHODONTIC MODELS Jean-Marc Retrouvey, Liliya Nicholcheva, Nathan Light TREATMENT PLANNING WITH DIGITAL ORTHODONTIC MODELS Jean-Marc Retrouvey, Liliya Nicholcheva, Nathan Light INTRODUCTION Digital orthodontic models are an accurate and reliable record of the patient s occlusion.

More information

Comparison Between Manual and Digital (2D) Measurement of Peer Assessment Rating (PAR) Score Index (Component 1-6)

Comparison Between Manual and Digital (2D) Measurement of Peer Assessment Rating (PAR) Score Index (Component 1-6) Comparison Between Manual and Digital (2D) Measurement of Peer Assessment Rating (PAR) Score Index (Component 1-6) Tri Wahyudi 1, Miesje Karmiati Purwanegara 2 *, Nada Ismah 2 1. Orthodontics Residency

More information

An Evaluation of the Use of Digital Study Models in Orthodontic Diagnosis and Treatment Planning

An Evaluation of the Use of Digital Study Models in Orthodontic Diagnosis and Treatment Planning Original Article An Evaluation of the Use of Digital Study in Orthodontic Diagnosis and Treatment Planning Brian Rheude a ; P. Lionel Sadowsky b ; Andre Ferriera c ; Alex Jacobson d Abstract: The purpose

More information

Comparative analyses of paediatric dental measurements using plaster and three-dimensional digital models

Comparative analyses of paediatric dental measurements using plaster and three-dimensional digital models Y. Kaihara*, A. Katayama**, K. Ono**, M. Kurose**, K. Toma**, H. Amano***, H. Nikawa**, K. Kozai**** Hiroshima University, Hiroshima, Japan *Department of Paediatric Dentistry, Hiroshima University Hospital

More information

Comparison of Measurements made on Plaster and CBCT-Scanned Models

Comparison of Measurements made on Plaster and CBCT-Scanned Models Comparison of Measurements made on Plaster and CBCT-Scanned Models Jared T. Lee 1, Thomas J. Cangialosi 2 1 Private Practice of Orthodontics, Santa Paula, California. 2 Professor and Chair, Department

More information

Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation

Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation Virginia Commonwealth University VCU Scholars Compass Theses and Dissertations Graduate School 2017 Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation Jason L.

More information

MDJ Accuracy of measurements made on digital and study Vol.:7 No.:1 2010

MDJ Accuracy of measurements made on digital and study Vol.:7 No.:1 2010 MDJ Accuracy of measurements made on digital and study models (A comparative study) Dr. Sawsan Mohammed Murad, B.D.S., M.Sc. Prof. Dr. Ausama A. Al-Mulla, B.D.S., Dr.D.SC.(France). Abstract Background:

More information

Evaluation of the validity of the Bolton Index using cone-beam computed tomography (CBCT)

Evaluation of the validity of the Bolton Index using cone-beam computed tomography (CBCT) Journal section: Clinical and Experimental Dentistry Publication Types: Research doi:10.4317/medoral.18069 http://dx.doi.org/doi:10.4317/medoral.18069 Evaluation of the validity of the Bolton Index using

More information

Royal London space analysis: plaster versus digital model assessment.

Royal London space analysis: plaster versus digital model assessment. Royal London space analysis: plaster versus digital model assessment. Grewal, B; Lee, RT; Zou, L; Johal, A The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society.

More information

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 25-372X http://dx.doi.org/1.441/kjod.216.46.3.129 Evaluation of digital dental models obtained from dental cone-beam computed tomography

More information

A cone-beam computed tomography evaluation of buccal bone thickness following maxillary expansion

A cone-beam computed tomography evaluation of buccal bone thickness following maxillary expansion Imaging Science in Dentistry 2013; 43: 85-90 http://dx.doi.org/10.5624/isd.2013.43.2.85 A cone-beam computed tomography evaluation of buccal bone thickness following maxillary expansion Sercan Akyalcin,

More information

Successful orthodontic treatment is based on extensive

Successful orthodontic treatment is based on extensive ORIGINAL ARTICLE Three-dimensional dental measurements: An alternative to plaster models Hend Mohammed El-Zanaty, a Amr Ragab El-Beialy, b Amr Mohammed Abou El-Ezz, c Khaled Hazem Attia, d Ahmed Ragab

More information

Application of augmented reality for inferior alveolar nerve block anesthesia: A technical note

Application of augmented reality for inferior alveolar nerve block anesthesia: A technical note Technical Note pissn 2383-9309 eissn 2383-9317 J Dent Anesth Pain Med 2017;17(2):129-134 https://doi.org/10.17245/jdapm.2017.17.2.129 Application of augmented reality for inferior alveolar nerve block

More information

The role of plaster models as an essential diagnostic tool in current orthodontic practice.

The role of plaster models as an essential diagnostic tool in current orthodontic practice. Original Research The role of plaster models as an essential diagnostic tool in current orthodontic practice. Shah et al * Authors: Adit Shah, Romina Kapadia**, Avinash Nawathe***, Purvesh Shah****, Dharmadev

More information

Anterior teeth root inclination prediction derived from digital models: A comparative study of plaster study casts and CBCT images

Anterior teeth root inclination prediction derived from digital models: A comparative study of plaster study casts and CBCT images Journal section: Orthodontics Publication Types: Research doi:10.4317/jced.55180 http://dx.doi.org/10.4317/jced.55180 Anterior teeth root inclination prediction derived from digital models: A comparative

More information

CLINICAL USE OF A DIRECT CHAIRSIDE ORAL SCANNER: AN ASSESSMENT OF ACCURACY, TIME, AND PATIENT PREFERENCE SHAWN D. MCCARTHY

CLINICAL USE OF A DIRECT CHAIRSIDE ORAL SCANNER: AN ASSESSMENT OF ACCURACY, TIME, AND PATIENT PREFERENCE SHAWN D. MCCARTHY CLINICAL USE OF A DIRECT CHAIRSIDE ORAL SCANNER: AN ASSESSMENT OF ACCURACY, TIME, AND PATIENT PREFERENCE A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY SHAWN

More information

Combined use of digital imaging technologies: ortho-surgical treatment

Combined use of digital imaging technologies: ortho-surgical treatment DOI: 10.1051/odfen/2018059 J Dentofacial Anom Orthod 2018;21:210 The authors Combined use of digital imaging technologies: ortho-surgical treatment L. Petitpas Private practice, 54700 Pont-à-Mousson Are

More information

Reliability and validity of intraoral and extraoral scanners

Reliability and validity of intraoral and extraoral scanners Jacob et al. Progress in Orthodontics (2015) 16:38 DOI 10.1186/s40510-015-0108-7 RESEARCH Open Access Reliability and validity of intraoral and extraoral scanners Helder B. Jacob, Graydon D. Wyatt and

More information

3D workflows in orthodontics, maxillofacial surgery and prosthodontics van der Meer, Wicher

3D workflows in orthodontics, maxillofacial surgery and prosthodontics van der Meer, Wicher University of Groningen 3D workflows in orthodontics, maxillofacial surgery and prosthodontics van der Meer, Wicher IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF)

More information

Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report Imaging Science in Dentistry 2012; 42 : 83-8 http://dx.doi.org/10.5624/isd.2012.42.2.83 Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report Drew M. Darsey,

More information

Case Report Orthodontic Treatment of a Mandibular Incisor Extraction Case with Invisalign

Case Report Orthodontic Treatment of a Mandibular Incisor Extraction Case with Invisalign Case Reports in Dentistry, Article ID 657657, 4 pages http://dx.doi.org/10.1155/2014/657657 Case Report Orthodontic Treatment of a Mandibular Incisor Extraction Case with Invisalign Khalid H. Zawawi Department

More information

Determining Tooth Size Ratio in an Iranian-Azari Population

Determining Tooth Size Ratio in an Iranian-Azari Population Determining Tooth Size Ratio in an Iranian-Azari Population Abstract Aim: The aim of this investigation was to determine the tooth size ratio in an Iranian-Azari population. Method and Materials: The Bolton

More information

AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015

AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015 AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015 Title: Clinical and iomechanical Considerations of TADs in Challenging Cases: Sagittal Correction beyond Orthodontic oundaries

More information

Using cone beam technology in orthodontics

Using cone beam technology in orthodontics PRACTICE US Using cone beam technology in orthodontics Continuing education earn 2 ce credits! Edward Lin explains the benefits of adding cone beam technology to the orthodontic armamentaria Since cone

More information

Changes of the Transverse Dental Arch Dimension, Overjet and Overbite after Rapid Maxillary Expansion (RME)

Changes of the Transverse Dental Arch Dimension, Overjet and Overbite after Rapid Maxillary Expansion (RME) Dental Journal Changes of the Transverse Dental Arch Dimension, Overjet and Overbite after Rapid Maxillary Expansion (RME) Department of Advanced General Dentistry Faculty of Dentistry, Mahidol University.

More information

A validation study of reconstructed rapid prototyping models produced by two technologies

A validation study of reconstructed rapid prototyping models produced by two technologies Zurich Open Repository and Archive University of Zurich Main Library Strickhofstrasse 39 CH-8057 Zurich www.zora.uzh.ch Year: 2017 A validation study of reconstructed rapid prototyping models produced

More information

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY THE EFFECTIVENESS OF SURESMILE TECHNOLOGY TO ACHIEVE PREDICTED TREATMENT OUTCOME A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY CHRISTOPHER JOHN VAUBEL IN PARTIAL

More information

Instability of tooth alignment and occlusal relationships

Instability of tooth alignment and occlusal relationships ORIGINAL ARTICLE Relapse revisited again Kenneth C. Dyer, a James L. Vaden, b and Edward F. Harris c Chattanooga, Cookeville, and Memphis, Tenn Introduction: Long-term changes in the dentitions of orthodontic

More information

Assessment of the Accuracy of Orthodontic Digital Models

Assessment of the Accuracy of Orthodontic Digital Models OPEN ACCESS EURASIA Journal of Mathematics Science and Technology Education ISSN: 13058223 (online) 13058215 (print) 2017 13(8):54655473 DOI: 10.12973/eurasia.2017.00844a Assessment of the Accuracy of

More information

A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models

A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 2005-372X A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models Ruhi

More information

Accuracy of Ortho Insight 3D Digital Scanner in Mesial-Distal Tooth Measurements

Accuracy of Ortho Insight 3D Digital Scanner in Mesial-Distal Tooth Measurements Loma Linda University TheScholarsRepository@LLU: Digital Archive of Research, Scholarship & Creative Works Loma Linda University Electronic Theses, Dissertations & Projects 8-1-2012 Accuracy of Ortho Insight

More information

Orthodontic Outcomes Assessment Using the Peer Assessment Rating Index

Orthodontic Outcomes Assessment Using the Peer Assessment Rating Index Original Article Orthodontic Outcomes Assessment Using the Peer Assessment Rating Index Renee Allen Dyken, DMD a ; P. Lionel Sadowsky, DMD, BDS, MDent, Dip Orth b ; David Hurst, PhD c Abstract: The purpose

More information

Chapter 2. Material and methods

Chapter 2. Material and methods Chapter 2 Material and methods Material and methods Summary This chapter describes the subjects and methods being used in this study. Between 1986 and 1997 9 expeditions were undertaken in remote areas

More information

Arch dimensional changes following orthodontic treatment with extraction of four first premolars

Arch dimensional changes following orthodontic treatment with extraction of four first premolars Received: 14 June. 2015 Accepted: 7 Dec. 2015 Arch dimensional changes following orthodontic treatment with extraction of four first premolars Abstract Asghar Ebadifar DDS, MSc 1, Mohammad Hossien Shafazand

More information

KJLO. A Sequential Approach for an Asymmetric Extraction Case in. Lingual Orthodontics. Case Report INTRODUCTION DIAGNOSIS

KJLO. A Sequential Approach for an Asymmetric Extraction Case in. Lingual Orthodontics. Case Report INTRODUCTION DIAGNOSIS KJLO Korean Journal of Lingual Orthodontics Case Report A Sequential Approach for an Asymmetric Extraction Case in Lingual Orthodontics Ji-Sung Jang 1, Kee-Joon Lee 2 1 Dream Orthodontic Clinic, Gimhae,

More information

Since its inception in 1929, the American Board of. Comparison of prospectively and retrospectively selected American Board of Orthodontics cases

Since its inception in 1929, the American Board of. Comparison of prospectively and retrospectively selected American Board of Orthodontics cases ONLINE ONLY Comparison of prospectively and retrospectively selected American Board of Orthodontics cases Blair H. Struble a and Greg J. Huang b Bend, Ore, and Seattle, Wash Introduction: In this study,

More information

Attachment G. Orthodontic Criteria Index Form Comprehensive D8080. ABBREVIATIONS CRITERIA for Permanent Dentition YES NO

Attachment G. Orthodontic Criteria Index Form Comprehensive D8080. ABBREVIATIONS CRITERIA for Permanent Dentition YES NO First Review IL HFS Dental Program Models Second Review Ortho cad Attachment G Orthodontic Criteria Index Form Comprehensive D8080 Ceph Film X-Rays Photos Narrative Patient Name: DOB: ABBREVIATIONS CRITERIA

More information

Case Report: Long-Term Outcome of Class II Division 1 Malocclusion Treated with Rapid Palatal Expansion and Cervical Traction

Case Report: Long-Term Outcome of Class II Division 1 Malocclusion Treated with Rapid Palatal Expansion and Cervical Traction Case Report Case Report: Long-Term Outcome of Class II Division 1 Malocclusion Treated with Rapid Palatal Expansion and Cervical Traction Roberto M. A. Lima, DDS a ; Anna Leticia Lima, DDS b Abstract:

More information

Disclosures. Objectives. CBCT in Dentistry and Research 4/17/2017. Protocols for CBCT Imaging

Disclosures. Objectives. CBCT in Dentistry and Research 4/17/2017. Protocols for CBCT Imaging Assessing Alveolar Bone Height and Thickness Using Cone Beam Computed Tomography: Are Looks Deceiving? American Association of Orthodontists April 25, 2017 David A. Covell, Jr., DDS, PhD Professor and

More information

Original Research Article

Original Research Article DOI: 10.21276/sjds.2016.3.6.5 Scholars Journal of Dental Sciences (SJDS) Sch. J. Dent. Sci., 2016; 3(6):175-179 Scholars Academic and Scientific Publisher (An International Publisher for Academic and Scientific

More information

Thakur H et al.applicability of various Mixed Dentition analysis among Sriganganagar School children

Thakur H et al.applicability of various Mixed Dentition analysis among Sriganganagar School children Original Article APPLICABILITY OF MOYER S AND TANAKA-JOHNSTON MIXED DENTITION ANALYSIS IN SCHOOL CHILDREN OF SRI GANGANAGAR DISTRICT (RAJASTHAN) A PILOT STUDY Thakur H, Jonathan PT Postgraduate student,

More information

Extraoral Imaging. Chapter 42. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

Extraoral Imaging. Chapter 42. Copyright 2018, Elsevier Inc. All Rights Reserved. 1 Extraoral Imaging Chapter 42 Copyright 2018, Elsevier Inc. All Rights Reserved. 1 Learning Objectives Lesson 42.1: Panoramic Imaging 1. Pronounce, define, and spell the key terms. 2. Discuss panoramic

More information

Two- and Three-dimensional Orthodontic Imaging Using Limited Cone Beam Computed Tomography

Two- and Three-dimensional Orthodontic Imaging Using Limited Cone Beam Computed Tomography Original Article Two- and Three-dimensional Orthodontic Imaging Using Limited Cone Beam Computed Tomography Akira Nakajima a ; Glenn T. Sameshima b ; Yoshinori Arai c ; Yoshito Homme d ; Noriyoshi Shimizu

More information

Indirect Bonding of Orthodontic Brackets: An evaluation of transfer accuracy and reliability

Indirect Bonding of Orthodontic Brackets: An evaluation of transfer accuracy and reliability Indirect Bonding of Orthodontic Brackets: An evaluation of transfer accuracy and reliability A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY Michael S. Lee IN

More information

Cephalometric Analysis

Cephalometric Analysis Cephalometric Analysis of Maxillary and Mandibular Growth and Dento-Alveolar Change Part III In two previous articles in the PCSO Bulletin s Faculty Files, we discussed the benefits and limitations of

More information

Evaluation of the occlusion and maxillary dental arch dimensions in the mixed dentitions of Yemeni population

Evaluation of the occlusion and maxillary dental arch dimensions in the mixed dentitions of Yemeni population From the SelectedWorks of Ahmed A. Madfa Winter January 19, 2015 Evaluation of the occlusion and maxillary dental arch dimensions in the mixed dentitions of Yemeni population Ahmed A. Madfa Available at:

More information

Facial planning for orthodontists and oral surgeons

Facial planning for orthodontists and oral surgeons ADVANCES IN ORTHODONTICS & DENTOFACIAL SURGERY Facial planning for orthodontists and oral surgeons G. William Arnett, DDS, FACD, a and Michael J. Gunson, DDS, MD b Santa Barbara, Calif The bite indicates

More information

Coronal height after expansion using a Damon system

Coronal height after expansion using a Damon system DOI: 10.1051/odfen/2017020 J Dentofacial Anom Orthod 2017;20:403 The authors Coronal height after expansion using a Damon system B. Ducroz 1, D. Brézulier 2, V. Bertaud-Gounot 3, O. Sorel 4 1 Qualified

More information

Correlation of Tooth Length Measurements made on CBCT and 3T MR Images

Correlation of Tooth Length Measurements made on CBCT and 3T MR Images Loma Linda University TheScholarsRepository@LLU: Digital Archive of Research, Scholarship & Creative Works Loma Linda University Electronic Theses, Dissertations & Projects 9-2016 Correlation of Tooth

More information

The mission of our company is the development of an individual approach in functional dentistry.

The mission of our company is the development of an individual approach in functional dentistry. The Prosystom company started up in 2013. It was created by Russian doctors and IT specialists for carrying out scientific projects and practical work in functional dentistry. The mission of our company

More information

3 Dimensional Diagnosis Unravelling Prognosis of Multiple Impacted Teeth A Case Report

3 Dimensional Diagnosis Unravelling Prognosis of Multiple Impacted Teeth A Case Report 3 Dimensional Diagnosis Unravelling Prognosis of Multiple Impacted Teeth A Case Report Adusumilli Gopinath 1, Naveen Admala Reddy 2, Mayur G Rohra 3 1 Professor, Department of Orthodontics, AME S Dental

More information

Original Article. Jae-Hong Kim a,b Ki-Baek Kim a,b Woong-Chul Kim a Ji-Hwan Kim a Hae-Young Kim a,b,c

Original Article. Jae-Hong Kim a,b Ki-Baek Kim a,b Woong-Chul Kim a Ji-Hwan Kim a Hae-Young Kim a,b,c Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 2005-372X http://dx.doi.org/10.4041/kjod.2014.44.2.69 Accuracy and precision of polyurethane dental arch models fabricated using

More information

Palatal Depth and Arch Parameter in Class I Open Bite, Deep Bite and Normal Occlusion

Palatal Depth and Arch Parameter in Class I Open Bite, Deep Bite and Normal Occlusion 26 Iraqi Orthod J 1(2) 2005 Palatal Depth and Arch Parameter in Class I Open Bite, Deep Bite and Normal Occlusion Ahmad A. Abdulmawjood, a Mahmood K. Ahmed, a and Ne am R. Al-Saleem a Abstract: This study

More information

The goal of orthodontic treatment is to move

The goal of orthodontic treatment is to move 2015 JCO, Inc. May not be distributed without permission. www.jco-online.com Generating an Ideal Virtual Setup with Three-Dimensional Crowns and Roots ROBERT J. LEE JOHN PHAM, DDS, MS ANDRE WEISSHEIMER,

More information

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines Original Research Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines Seyed Hossein Hoseini Zarch 1, Farzin Heravi 2, Adineh Javadian Langaroodi 3,

More information

EFFICACY OF COMPOSITE TOOTH ATTACHMENTS IN CONJUNCTION WITH THE INVISALIGN SYSTEM USING THREE-DIMENSIONAL DIGITAL TECHNOLOGY

EFFICACY OF COMPOSITE TOOTH ATTACHMENTS IN CONJUNCTION WITH THE INVISALIGN SYSTEM USING THREE-DIMENSIONAL DIGITAL TECHNOLOGY EFFICACY OF COMPOSITE TOOTH ATTACHMENTS IN CONJUNCTION WITH THE INVISALIGN SYSTEM USING THREE-DIMENSIONAL DIGITAL TECHNOLOGY By SHARON J. DURRETT A THESIS PRESENTED TO THE GRADUATE SCHOOL OF THE UNIVERSITY

More information

Orthodontic space opening during adolescence is

Orthodontic space opening during adolescence is ONLINE ONLY Postorthodontic root approximation after opening space for maxillary lateral incisor implants Taylor M. Olsen a and Vincent G. Kokich, Sr b Seattle, Wash Introduction: Orthodontic space opening

More information

Developing Facial Symmetry Using an Intraoral Device: A Case Report

Developing Facial Symmetry Using an Intraoral Device: A Case Report Developing Facial Symmetry Using an Intraoral Device: A Case Report by Theodore R. Belfor, D.D.S.; and G. Dave Singh, D.D.Sc., Ph.D., B.D.S. Dr. Theodore Belfor graduated from New York University College

More information

Class III malocclusion occurs in less than 5%

Class III malocclusion occurs in less than 5% CDABO CASE REPORT Orthodontic correction of a Class III malocclusion in an adolescent patient with a bonded RPE and protraction face mask Steven W. Smith, DDS, a and Jeryl D. English, DDS, MS b Dallas,

More information

Class II Correction using Combined Twin Block and Fixed Orthodontic Appliances: A Case Report

Class II Correction using Combined Twin Block and Fixed Orthodontic Appliances: A Case Report Case Report Print ISSN: 2321-6379 Online ISSN: 2321-595X DOI: 10.17354/ijss/2017/506 Class II Correction using Combined Twin Block and Fixed Orthodontic Appliances: A Case Report Ahmed Alassiry Assistant

More information

Invisalign technique in the treatment of adults with pre-restorative concerns

Invisalign technique in the treatment of adults with pre-restorative concerns Mampieri and Giancotti Progress in Orthodontics 2013, 14:40 REVIEW Open Access Invisalign technique in the treatment of adults with pre-restorative concerns Gianluca Mampieri * and Aldo Giancotti Abstract

More information

Keywords Cone beam computed tomography, impacted maxillary canine, palatal depth and width

Keywords Cone beam computed tomography, impacted maxillary canine, palatal depth and width 32 Investigating the correlation between palatal depth and width measurements in impacted maxillary canine patients by using cone beam computed tomography 1 Omar Faruq Mohammed, B.D.S., 2 Alah Dawood Mahmood,

More information

Tooth Length Measurements on 3T MR Images: A Retrospective Study

Tooth Length Measurements on 3T MR Images: A Retrospective Study Loma Linda University TheScholarsRepository@LLU: Digital Archive of Research, Scholarship & Creative Works Loma Linda University Electronic Theses, Dissertations & Projects 9-2015 Tooth Length Measurements

More information

During orthodontic treatment, the alignment of

During orthodontic treatment, the alignment of TECHNO BYTES Comparison of mesiodistal root angulation with posttreatment panoramic radiographs and cone-beam computed tomography Daniel G. Bouwens, a Lucia Cevidanes, b John B. Ludlow, c and Ceib Phillips

More information

The practice of orthodontics is faced with new

The practice of orthodontics is faced with new CLINICIAN S CORNER A new approach to correction of crowding William Randol Womack, DDS, a Jae H. Ahn, DDS, MSD, b Zahra Ammari, DDS, MDSc, c and Anamaría Castillo, DDS, MS c Phoenix, Ariz, and Santa Clara,

More information

Dental Cone Beam CT. What is Dental Cone Beam CT?

Dental Cone Beam CT. What is Dental Cone Beam CT? Scan for mobile link. Dental Cone Beam CT Dental cone beam computed tomography (CT) is a special type of x-ray equipment used when regular dental or facial x-rays are not sufficient. Your doctor may use

More information

Quantitation of transverse maxillary dimensions using computed tomography: a methodological and reproducibility study

Quantitation of transverse maxillary dimensions using computed tomography: a methodological and reproducibility study European Journal of Orthodontics 26 (2004) 209 215 European Journal of Orthodontics vol. 26 no. 2 European Orthodontic Society 2004; all rights reserved. Quantitation of transverse maxillary dimensions

More information

Prediction of Root Form Using Crown Data: Mandibular Left First Premolar

Prediction of Root Form Using Crown Data: Mandibular Left First Premolar Loma Linda University TheScholarsRepository@LLU: Digital Archive of Research, Scholarship & Creative Works Loma Linda University Electronic Theses, Dissertations & Projects 9-2017 Prediction of Root Form

More information

ASSESSMENT OF MAXILLARY FIRST MOLAR ROTATION IN SKELETAL CLASS II, AND THEIR COMPARISON WITH CLASS I AND CLASS III SUBJECTS

ASSESSMENT OF MAXILLARY FIRST MOLAR ROTATION IN SKELETAL CLASS II, AND THEIR COMPARISON WITH CLASS I AND CLASS III SUBJECTS ORIGINAL ARTICLE ASSESSMENT OF MAXILLARY FIRST MOLAR ROTATION IN SKELETAL CLASS II, AND THEIR COMPARISON WITH CLASS I AND CLASS III SUBJECTS ABSTRACT FARHAT AMIN, BDS, MCPS, FCPS Mesial rotation of maxillary

More information

Current Products and Practices Applications of 3D imaging in orthodontics: Part II

Current Products and Practices Applications of 3D imaging in orthodontics: Part II Journal of Orthodontics, Vol. 31, 2004, 154 162 FEATURES SECTION Current Products and Practices Applications of 3D imaging in orthodontics: Part II M. Y. Hajeer University of Albaath Dental School, Damascus,

More information

Comparison between Tanaka/Johnston and Boston University prediction approaches in a group of Iraqi pupils

Comparison between Tanaka/Johnston and Boston University prediction approaches in a group of Iraqi pupils ISSN: 1812 1217 Comparison between Tanaka/ and prediction approaches in a group of Iraqi pupils Khawla M Awni BDS, MSc (Assist Lect) Dept of Pedod, Orthod and Prev Dent College of Dentistry, of Mosul ABATRACT

More information

The removal of permanent teeth has been a

The removal of permanent teeth has been a ORIGINAL ARTICLE Cephalometric changes in overbite and vertical facial height after removal of 4 first molars or first premolars Mark G. Hans, a Gordon Groisser, b Clay Damon, c Douglas Amberman, d Suchitra

More information

In-Office Cone Beam Computerized Tomography: Technology Review and Clinical Examples Michael Tischler, DDS

In-Office Cone Beam Computerized Tomography: Technology Review and Clinical Examples Michael Tischler, DDS Page 1 of 8 Issue Date: June 2008, Posted On: 6/26/2008 In-Office Cone Beam Computerized Tomography: Technology Review and Clinical Examples Michael Tischler, DDS Electronic Medical Record Research EMR

More information

Corporate Medical Policy

Corporate Medical Policy Corporate Medical Policy File Name: Origination: Last CAP Review: Next CAP Review: Last Review: orthodontics_for_pediatric_patients 2/2014 10/2017 10/2018 10/2017 Description of Procedure or Service Children

More information

ISW for the treatment of adult anterior crossbite with severe crowding combined facial asymmetry case

ISW for the treatment of adult anterior crossbite with severe crowding combined facial asymmetry case International Research Journal of Medicine and Biomedical Sciences Vol.3 (2),pp. 15-29, November 2018 Available online at http://www.journalissues.org/irjmbs/ https://doi.org/10.15739/irjmbs.18.004 Copyright

More information

Correction of a maxillary canine-first premolar transposition using mini-implant anchorage

Correction of a maxillary canine-first premolar transposition using mini-implant anchorage CASE REPORT Correction of a maxillary canine-first premolar transposition using mini-implant anchorage Mehmet Oguz Oztoprak, DDS, MSc, a Cigdem Demircan, DDS, b Tulin Arun, PhD, DDS, MSc c Transposition

More information

Comparison of occlusal contact areas of class I and class II molar relationships at finishing using three-dimensional digital models

Comparison of occlusal contact areas of class I and class II molar relationships at finishing using three-dimensional digital models Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 2005-372X http://dx.doi.org/10.4041/kjod.2015.45.3.113 Comparison of occlusal contact areas of class I and class II molar relationships

More information

Variation in Mesiodistal Root Angulation of Panoramic Images Generated from Cone-beam Computed Tomography

Variation in Mesiodistal Root Angulation of Panoramic Images Generated from Cone-beam Computed Tomography Variation in Mesiodistal Root Angulation of Panoramic Images Generated from Cone-beam Computed Tomography Si Qi LIU 1, Fu Jia WEN 1, Hua CHEN 2, Yi LIU 1 Objective: To compare the mesiodistal root angulation

More information

With judicious treatment planning, the clinical

With judicious treatment planning, the clinical CLINICIAN S CORNER Selecting custom torque prescriptions for the straight-wire appliance Earl Johnson San Francisco, Calif Selecting custom torque prescriptions based on the treatment needs of each patient

More information

Treatment of Class II non-extraction using the Bioprogressive method

Treatment of Class II non-extraction using the Bioprogressive method DOI: 10.1051/odfen/2014013 J Dentofacial Anom Orthod 2014;17:407 Ó RODF / EDP Sciences Treatment of Class II non-extraction using the Bioprogressive method P. Guezenec CD SQODF, membre titulaire de la

More information

Virtual model surgery and wafer fabrication for orthognathic surgery

Virtual model surgery and wafer fabrication for orthognathic surgery Int. J. Oral Maxillofac. Surg. 2009; 38: 1306 1323 available online at http://www.sciencedirect.com Technical Note Orthognathic Surgery Virtual model surgery and wafer fabrication for orthognathic surgery

More information

Objective: There is little information regarding the mesiodistal angulation of permanent teeth

Objective: There is little information regarding the mesiodistal angulation of permanent teeth www.scielo.br/jaos Mesiodistal root angulation of permanent teeth in children with mixed dentition and normal occlusion Flávia A. S. JESUINO 1, Luciane R. COSTA 2, José VALLADARES-NETO 3 1- DDS, MSc, PhD,

More information

Evaluation of Correlation between Wits Appraisal and a New Method for Assessment of Sagittal Relationship of Jaws

Evaluation of Correlation between Wits Appraisal and a New Method for Assessment of Sagittal Relationship of Jaws Original Article Evaluation of Correlation between Wits Appraisal and a New Method for Assessment of Sagittal Relationship of Jaws Z. Hedayati 1, S. Heidari 2, F. Khaje 3 1 Orthodontic Research Center,

More information

Mean Leeway space in Indian population

Mean Leeway space in Indian population Original article: Mean Leeway space in Indian population 1Dr. Suchita Madhukar Tarvade (Daokar), 2 Dr. Gauri Rajkumar Agrawal, 3 Dr. Sadashiv Daokar 1Professor & PG Guide, Dept of Orthodontics, CSMSS Dental

More information

Reliability of A and B point for cephalometric analysis

Reliability of A and B point for cephalometric analysis Reliability of A and B point for cephalometric analysis Angle East Washington DC March, 2015 Carl P Roy, DDS, MS 1 History Orthodontic profession has always attempted to classify malocclusions. A-P relationship

More information

The reliability and validity of the Index of Complexity, Outcome and Need for determining treatment need in Dutch orthodontic practice

The reliability and validity of the Index of Complexity, Outcome and Need for determining treatment need in Dutch orthodontic practice European Journal of Orthodontics 28 (2006) 58 64 doi:10.1093/ejo/cji085 Advance Access publication 8 November 2005 The Author 2005. Published by Oxford University Press on behalf of the European Orthodontics

More information

Management of Crowded Class 1 Malocclusion with Serial Extractions: Report of a Case

Management of Crowded Class 1 Malocclusion with Serial Extractions: Report of a Case Management of Crowded Class 1 Malocclusion with Serial Extractions: Report of a Case Hayder A. Hashim, BDS, MSc Abstract Aim: The purpose of this article is to show the value of serial extractions in a

More information

Biomedical Research 2017; 28 (8): ISSN X

Biomedical Research 2017; 28 (8): ISSN X Biomedical Research 2017; 28 (8): ISSN 0970-938X www.biomedres.info Application of computer aided design and fused deposition modeling technology in the digital manufacture of orthodontic study models.

More information

The conservative treatment of Class I malocclusion with maxillary transverse deficiency and anterior teeth crowding

The conservative treatment of Class I malocclusion with maxillary transverse deficiency and anterior teeth crowding B B O C a s e R e p o r t The conservative treatment of Class I malocclusion with maxillary transverse deficiency and anterior teeth crowding Lincoln I. Nojima* Abstract This report describes the treatment

More information

The ASE Example Case Report 2010

The ASE Example Case Report 2010 The ASE Example Case Report 2010 The Requirements for Case Presentation in The Angle Society of Europe are specified in the Appendix I to the Bylaws. This example case report exemplifies how these requirements

More information

SureSmile, An Unbiased Review. Timothy J Alford, DDS, MSD

SureSmile, An Unbiased Review. Timothy J Alford, DDS, MSD SureSmile, An Unbiased Review Timothy J Alford, DDS, MSD *I, declare that neither I nor any member of my family have a financial arrangement or affiliation with any corporate organization offering financial

More information

The goal of diagnosis and treatment planning

The goal of diagnosis and treatment planning Three-dimensional diagnosis & treatment planning: The use of 3D facial imaging and 3D cone beam CT in orthodontics and dentistry By William E. Harrell, Jr, DMD Threedimensional imaging and its use over

More information

Mandibular incisor extraction: indications and long-term evaluation

Mandibular incisor extraction: indications and long-term evaluation European Journal of Orthodontics 18 (1996) 485-489 O 1996 European Orthodontic Society Mandibular incisor extraction: indications and long-term evaluation Jose-Antonio Canut University of Valencia, Spain

More information

Angle Class II, division 2 malocclusion with deep overbite

Angle Class II, division 2 malocclusion with deep overbite BBO Case Report Angle Class II, division 2 malocclusion with deep overbite Arno Locks 1 Angle Class II, division 2, malocclusion is characterized by a Class II molar relation associated with retroclined

More information

Dental-arch form consists of both size and shape.

Dental-arch form consists of both size and shape. ORIGINAL ARTICLE A comparison of dental arch forms between Class II Division 1 and normal occlusion assessed by euclidean distance matrix analysis Qiong Nie a and Jiuxiang Lin b Beijing, China Introduction:

More information

The validation of the Peer Assessment Rating index for malocclusion severity and treatment difficulty

The validation of the Peer Assessment Rating index for malocclusion severity and treatment difficulty The validation of the Peer Assessment Rating index for malocclusion severity and treatment difficulty L. DeGuzman, DMD," D. Bahiraei, BS, DMD," K. W. L. Vig, BDS, MS, FDS, D.Orth., b P. S. Vig, BDS, FDS,

More information