Assessment of nickel titanium and beta titanium corrosion resistance behavior in fluoride and chloride environments

Size: px
Start display at page:

Download "Assessment of nickel titanium and beta titanium corrosion resistance behavior in fluoride and chloride environments"

Transcription

1 Original Article Assessment of nickel titanium and beta titanium corrosion resistance behavior in fluoride and chloride environments Elisa J. Kassab a ; José Ponciano Gomes b ABSTRACT Objective: To assess the influence of fluoride concentration on the corrosion behavior of nickel titanium (NiTi) superelastic wire and to compare the corrosion resistance of NiTi with that of beta titanium alloy in physiological solution with and without addition of fluoride. Materials and Methods: NiTi corrosion resistance was investigated through electrochemical impedance spectroscopy and anodic polarization in sodium chloride (NaCl 0.15 M) with and without addition of 0.02 M sodium fluoride (NaF), and the results were compared with those associated with beta titanium. The influence of fluoride concentration on NiTi corrosion behavior was assessed in NaCl (0.15 M) with and without 0.02, 0.04, 0.05, 0.07, and 0.12 M NaF solution. Galvanic corrosion between NiTi and beta titanium were investigated. All samples were characterized by scanning electron microscopy. Results: Polarization resistance decreased when NaF concentration was increased, and, depending on NaF concentration, NiTi can suffer localized or generalized corrosion. In NaCl solution with 0.02 M NaF, NiTi suffer localized corrosion, while beta titanium alloys remained passive. Current values near zero were observed by galvanic coupling of NiTi and beta titanium. Conclusions: There is a decrease in NiTi corrosion resistance in the presence of fluoride. The corrosion behavior of NiTi alloy depends on fluoride concentration. When 0.02 and 0.04 M of NaF were added to the NaCl solution, NiTi presented localized corrosion. When NaF concentration increased to 0.05, 0.07, and 0.12 M, the alloy presented general corrosion. NiTi corrosion resistance behavior is lower than that of beta titanium. Galvanic coupling of these alloys does not increase corrosion rates. (Angle Orthod. 2013;83: ) KEY WORDS: Nickel titanium wires; Corrosion; Fluoride INTRODUCTION Nickel titanium (NiTi) alloys have been widely used in biomedical and dental applications because of their special mechanical properties and good biocompatibility. 1 Their mechanical properties namely, shape memory effect and superelasticity are based on a a PhD Student, Department of Metallurgy and Materials Science, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil. b Professor, Department of Metallurgy and Materials, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil. Corresponding author: Elisa J. Kassab, Department of Metallurgy and Materials Science, Federal University of Rio de Janeiro, Cid. Universitária Centro de Tecnologia-Bloco F, 210, Ilha do Fundão Postal Box 68505, Rio de Janeiro, RJ , Brazil ( elisajk@metalmat.ufrj.br) Accepted: January Submitted: September Published Online: February 28, 2013 G 2013 by The EH Angle Education and Research Foundation, Inc. martensitic phase transformation, which allows the NiTi alloys to return to a previously defined shape when strained up to 8%. 2 For orthodontic application, NiTi equiatomic alloys can provide lighter and more constant force to dental movement. 3 Clinically, this controlled force results in longer dental appointment intervals. However, these good mechanical properties are not essentially accompanied by an improvement in corrosion resistance. The poor corrosion resistance might not only affect the treatment effectiveness but may also result in toxic and allergic reactions due to nickel release. In addition, the biocompatibility of NiTi is still under discussion. 4 A protection layer is formed on NiTi and the titanium surface when it comes in contact with the aqueous environment. While on the titanium surface the film is constituted by titanium oxide (TiO 2 ), on NiTi the passive film also has the presence of smaller amounts of nickel oxide or metallic Ni, 5 which make it more susceptible to chemical attack. Nickel release may be a problem in a biomaterial, once Ni has been described as a toxic 6 and allergic ion. 7 A 864 DOI: /

2 NITI BETA TITANIUM CORROSION FLUORIDE CHLORIDE 865 Table 1. Mean Corrosion Potential Values of Nickel Titanium (NiTi) Wires After 1-Hour Immersion Time in Different Sodium Fluoride (NaF) Concentrations a NaF, M E corr /mv, SCE a SCE indicates saturated calomel electrode. recent study 8 found a significant increase in Ni content in saliva in patients using NiTi fixed orthodontic appliances. Several surface treatments have been developed in order to decrease nickel release and by favoring the formation of a stable TiO 2 layer. 9,10 The effect of the addition of a third element (such as copper, iron, or palladium) to the binary NiTi has also been recently researched. The ternary NiTi-based alloys presented a lower localized corrosion resistance than does the binary NiTi. 5 The aim of this work is to understand NiTi corrosion behavior in 0.15 M sodium chloride (NaCl) with and without addition of fluoride. The oral cavity is a potential corrosive environment for orthodontic arch wires as a result of its Cl 2 ion concentration. Moreover, fluoride therapy is well known as an effective method to prevent dental caries. 11 It has also been described 12 that Ti, which has excellent corrosion resistance behavior, might suffer localized attack in fluoride environments. In order to investigate the corrosion behavior of NiTi alloy, a comparative study with beta titanium alloy was carried out, since beta titanium can be used as reference of good corrosion resistance. MATERIALS AND METHODS The materials used for the study were NiTi and beta titanium wires. The NiTi alloy used was a 0.02-inch superelastic wire with a chemical composition comprising wt. % Ni, 227 ppm of carbon, 280 ppm of oxygen, and balanced Ti. The NiTi wires were ordered by Memory-Metalle GmbH (Weil am Rhein, BW, Germany; batch No. C A). The beta titanium commercial orthodontic wire had a 0.03-inch diameter and was produced by GAC International Inc (Bohemia, New York). The following solutions were prepared as electrolytes: 0.15 M NaCl pure (Vetec), with additions of 0.02, 0.04, 0.05, 0.07, and 0.12 M sodium fluoride (NaF; Riedel-de Haen). Diluted HCl solution was used to adjust the ph of the solutions containing fluoride to 5.5 in order to obtain the same ph value of pure NaCl solution. The electrochemical experiments were performed in a threeelectrode electrochemical cell with a saturated calomel electrode used as a reference electrode and platinum as a counter electrode (Figure 1). This cell was connected to a potentiostat (Metrohm Autolab). Corrosion resistance was studied using anodic potentiodynamic polarization at a potential scanning of 20 mv/min and electrochemical impedance spectroscopy measurement at open-circuit potential, with a sinusoidal signal of 10-mV amplitude and frequencies in the range of 10 khz to 10 mhz. Prior to the electrochemical experiments the working electrodes were immersed in solution for 1 hour. The NiTi wires were observed using scanning electron microscopy (SEM) for surface analysis. To assess the galvanic corrosion behavior of NiTi in combination with beta titanium, the different wires were immersed in NaCl containing 0.02 M NaF solution and were connected by the built-in zero-resistance ammeter. The current flow resulting when these materials were galvanically coupled was recorded. RESULTS NiTi Corrosion Behavior Depending on Fluoride Concentration Corrosion potential (E corr ) measured at the end of the 1-hour immersion period is presented in Table 1 and shows that more negative E corr values are related to higher fluoride concentrations. This indicates a lower protection capacity of the oxide layer with increasing fluoride concentration. The difference in E corr obtained in the lowest F 2 concentration (0.02 M) and the highest F 2 concentration (0.12 M) was 113 mv. Figure 2 shows anodic polarization curves in different fluoride concentrations. In solution containing 0.02 and 0.04 M NaF the material remains passive until its breakdown potential, beyond which a breakdown of passivity layer occurs. From this potential, an average of 220 mv for 0.02 M concentration and 240 mv for 0.04 NaF concentrations, the current density increases, and localized corrosion of the material occurs. From 0.05 M fluoride ion concentration and above, the current densities are higher, which indicates active dissolution of the material. Comparing SEM images (Figure 3), the wire tested in 0.04 M NaF shows the presence of pits on the sample surface, while there is no significant surface alteration in 0.07 M NaF. Electrochemical impedance spectroscopy (EIS) measurements (Figure 4a,b) show capacitive arcs in all fluoride concentrations. The Nyquist diagrams reveal that the polarization resistance (R p ) decreases with an increase in fluoride concentration. This justifies the notion that the decrease in corrosion resistance is related to higher fluoride concentrations. The points

3 866 KASSAB, GOMES Figure 1. Experimental three-electrode set-up used for corrosion experiments. The arrows indicate the working electrode (WE), the reference electrode (RE), and the counter electrode (CE). at which the curves intersect the x-axis were deduced as R p. The R p values varied between 600 kvcm 2 in NaCl solution with 0.02 M NaF and 1kVcm 2 in the electrolyte containing 0.12 M NaF. Figure 4c shows the changes in R p with fluoride concentration. Figure 2. Anodic polarization measurements of NiTi in 0.15 M NaCl solutions with different fluoride concentrations. Figure 3. SEM images at 1003 magnification from (a) NiTi wire tested in NaCl solution with 0.04 M NaF and (b) NiTi wire tested in NaCl solution with 0.07 M NaF. Comparative Study Between NiTi and Beta Titanium Through Electrochemical Measurements A comparative study with Ti, which is described as having good corrosion resistance, was carried out in NaCl solution with and without 0.02 M NaF. The mean corrosion potential after 1 hour is shown in Table 2. Beta titanium presented higher E corr than does NiTi. Both materials presented more negative E corr when fluoride was in the solution, thus indicating a decrease in corrosion resistance of NiTi and beta titanium when in the presence of fluoride. The EIS graphic confirms lower impedance of the passivation film when fluoride is present, since there is a decrease in polarization resistance in this condition (Figure 5). The polarization curve is shown in Figure 6. Beta titanium remains passive in both electrolytes, with low current densities. However, current density increases when the alloy is tested in an environment containing fluoride, indicating a decrease in corrosion resistance in this condition. Passive current density ranged from 0.02 ma/cm 2 in NaCl 0.15 M to 0.07 ma/cm 2 in NaCl with 0.02 M NaF. NiTi, on the other hand, presented different corrosion behavior in solution with and without fluoride. In NaCl electrolyte, the material remained passive, with passive current density of 0.04 ma/cm 2. When fluoride was added into the solution, the current density increased, characterizing localized corrosion, with a mean pitting potential (E pit ) of 240 mv and a passivation current density of 0.2 ma/cm 2.

4 NITI BETA TITANIUM CORROSION FLUORIDE CHLORIDE 867 Figure 5. EIS measurements of NiTi and beta titanium. Galvanic Couple Galvanic corrosion between NiTi and beta titanium was also evaluated because of the electrode potential gap measured between NiTi and beta titanium alloys in NaCl with 0.02 M fluoride solution. In vivo, galvanic corrosion may occur when NiTi wires and titanium brackets are in contact. The study was conducted through current measurement carried out by connecting two electrodes of the materials after a 1-hour immersion period in the solution (Figure 7). After an initial current peak, the current remained stable and the values were around zero. DISCUSSION The anodic polarization test with different fluoride concentration showed that for the same ph, there is a fluoride concentration at which the corrosion resistance behavior of the NiTi alloy changes. In solutions containing 0.02 and 0.04 M NaF, an oxide layer is formed, but there is a breakdown in the passivity layer, Figure 4. EIS measurements of NiTi in 0.15 M NaCl with different fluoride concentrations. (a) EIS in 0.12, 0.07, and 0.05 M NaF. (b) EIS in 0.05, 0.04, and 0.02 M NaF. (c) R p variation with fluoride concentration. Table 2. Mean Corrosion Potential (E corr ) Values of Nickel Titanium (NiTi) and Beta Titanium in Sodium Chloride (NaCl) Either Containing or Not Containing 0.02 M Sodium Fluoride (NaF), E corr /mv NaCl NaCl + NaF NiTi Beta titanium Figure 6. Anodic polarization curves of NiTi and beta titanium.

5 868 KASSAB, GOMES Figure 7. Current evaluation with time of NiTi and beta titanium galvanic couple in NaCl containing 0.02 M NaF. characterized by localized corrosion. From 0.05 to 0.12 M NaF there is no formation of a passive layer, and the NiTi alloy suffered active dissolution, since current densities start at high values from the open circuit potential, as shown in Figure 2. Localized corrosion can be more prejudicial than generalized corrosion, since the pits can act like preferential locations of crack initiation (Figure 3). Cracks on the wire surface could reduce the force that should be employed in dental movement and prolong orthodontic treatment. Walker et al. 13 observed a decrease in unloading mechanical properties of NiTi exposed to topic fluoride. Previous investigations have shown that fluoride ion can reduce the corrosion resistance of NiTi alloy. There are reports of general corrosion 14 and localized corrosion. 6 In this work, the results show that there is a critical fluoride concentration at which NiTi can be damaged by localized corrosion. In solutions with 0.02 and 0.04 M of fluoride, NiTi suffered localized corrosion and, from 0.5 M NaF and above, generalized corrosion. EIS measurements show that lower R p values are related to higher fluoride concentration (Figure 4). The lower R p from samples tested in 0.04 M NaF compared to 0.02 M indicates a less corrosionresistant film when fluoride concentration is increased. From 0.05 to 0.12 M of fluoride the lower impedance can be associated with the absence of an oxide film, resulting in active dissolution. It is important to point out that beta titanium did not present localized corrosion susceptibility in the fluoride solution. The current densities were up to A/cm 2, as shown in Figure 6. However, beta titanium alloy has also presented a lower resistant passivation film in fluoride presence, as can be seen through lower values of impedance in fluoride solution (Figure 5). The lower corrosion resistance presented by NiTi can likely be justified by the composition of the oxide layer formed on the NiTi surface. Despite the main formation of TiO 2, previous reports 5,15 indicate that the passive layer also consists of Ni oxides or metallic Ni. The presence of Ni ions and Ni oxides can explain why NiTi suffered localized corrosion in NaCl environments with fluoride, while beta titanium, which forms only TiO 2 in its surface, did not exhibit localized corrosion. In our work, NiTi did not presented localized corrosion in chloride solutions, probably because of the good surface conditions of our samples, which influenced the stability of the oxide layer formed on the NiTi surface. Previous research 16 has shown that surface treatments, such as polishing, reduce the surface roughness and decrease the corrosion rates of NiTi alloys. In our investigation, we could not find localized corrosion in chloride environments, as described in references. 5,17 Another work 18 suggests that the manufacturing process of the orthodontic arch wires might also have a strong influence on the corrosion resistance of the NiTi alloys. The galvanic corrosion test indicates that the NiTi corrosion rate does not change when in contact with beta titanium in NaCl solution. When NiTi and beta titanium were coupled, current values remained low and near zero after a current peak. Similar results have been also reported 19 in Hank s solution. Attenuation of the galvanic current occurred as a consequence of the high impedance of the electrodes, as indicated by the Nyquist diagrams presented in Figure 5. CONCLUSIONS N NiTi corrosion resistance behavior is lower than that of beta titanium. In NaCl solution with 0.02 M NaF, NiTi wires are susceptible to localized corrosion, while beta titanium alloy does not show localized corrosion. Localized corrosion of NiTi wires could prolong orthodontic treatment. N The corrosion behavior of NiTi alloy depends on fluoride concentration. When 0.02 and 0.04 M of NaF were added to the NaCl solution, NiTi presented localized corrosion. When NaF concentration increased to 0.05, 0.07, and 0.12 M, the alloy presented general corrosion. N There is no galvanic corrosion between NiTi and beta titanium in 0.15 M NaCl and 0.02 M NaF electrolytes, since the current values remained around zero. ACKOWLEDGMENTS The authors acknowledge funding by the Coordenação de Aperfeiçoamento de Pessoal de Nível superior (CAPES) and the Fundação Coordenação de Projetos, Pesquisas e Estudos Tecnológicos (Fundação COPPETEC). The authors are also grateful to Lakshman Neelakantan for useful comments.

6 NITI BETA TITANIUM CORROSION FLUORIDE CHLORIDE 869 REFERENCES 1. Duerig TW, Pelton AR, Stockel D. The utility of superelasticity in medicine. Bio-Med Mater Eng. 1996;6: Dayananda GN, Subba Rao M. Effect of strain rate on properties of superelastic NiTi thin wires. Mater Sci Eng A Struct Mater. 2008;486: Yokoyama K, Hamada K, Moriyama K, Asaoka K. Degradation and fracture of Ni-Ti superelastic wire in an oral cavity. Biomaterials. 2001;22: Bogdanski D, Köller M, Müller D, et al. Easy assessment of the biocompatibility of Ni-Ti alloys by in vitro cell culture experiments on a functionally graded Ni-NiTi-Ti material. Biomaterials. 2002;23: Kassab E, Neelakantan L, Frotscher M, et al. Effect of ternary element addition on the corrosion behavior of NiTi shape memory alloys. Mater Corros doi: / maco Kao C, Ding S, He H, Chou MY, Huang T. Cytotoxicity of orthodontic wire corroded in fluoride solution in vitro. Angle Orthod. 2007;77: Schäfer TE, Böhler E, Ruhdorfer S. Epidemiology of contact allergy in adults. Allergy. 2001;56: Amini F, Jafari A, Amini P, Sepasi S. Metal ion release from fixed orthodontic appliances an in vivo study. Eur J Orthod. 2012;34: Espinar E, Llamas JM, Michiardi A, Ginebra MP, Gil FJ. Reduction of Ni release and improvement of the friction behavior of NiTi orthodontic archwires by oxidation treatments. J Mater Sci Mater Med. 2011;22: Surmenev RA, Ryabtseva MA, Shesterikov EV, Pichugin VF, Peitsch T, Epple M. The release of nickel from nickel titanium (NiTi) is strongly reduced by a sub-micrometer thin layer of calcium phosphate. J Mater Sci Mater Med. 2010; 21: Clarkson JJ, McLoughlin J. Role of fluoride in oral health promotion. Int Dent J. 2000;50: Könönen MHO, Lavonius ET, Kivilahti JK. SEM observations on stress corrosion cracking of commercially pure titanium in a topical fluoride solution. Dent Mater. 1995;11: Walker MP, White RJ, Kula KS. Effect of fluoride prophylactic agents on the mechanical properties of nickeltitanium-based orthodontic wires. Am J Orthod Dentofacial Orthop. 2005;127: Li X, Wang J, Han E, Ke W. Influence of fluoride and chloride on corrosion behavior of NiTi orthodontic wire. Acta Biomater. 2007;3: Lee TH, Huang TK, Lin SY, Chen LK, Chou MY, Huang HH. Corrosion resistance of different nickel-titanium archwires in acidic fluoride-containing artificial saliva. Angle Orthod. 2010;80: Hunt NP, Cunningham SJ, Golden CG, Sheriff M. An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires. Angle Orthod. 1999;69: Wang J, Li N, Rao G, Han E, Ke W. Stress corrosion cracking of NiTi in artificial saliva. Dent Mater. 2007;23: Huang H. Variation in corrosion resistance of nickel-titanium wires from different manufacturers. Angle Orthod. 2005;75: Venugopalan R, Trépanier C. Assessing the corrosion behaviour of Nitinol for minimally-invasive device design. Minim Invasive Ther. 2000;9:67.

INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION

INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION Materials Science, Vol. 47, No. 6, May, 2012 (Ukrainian Original Vol. 47, No. 6, November December, 2011) INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION

More information

Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride

Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride Leonardo Journal of Sciences ISSN 1583-0233 Issue 11, July-December 2007 p. 33-40 Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride Latifa KINANI and Abdelilah CHTAINI* Equipe d

More information

Assessing the corrosion behaviour of Nitinol for minimally-invasive device design

Assessing the corrosion behaviour of Nitinol for minimally-invasive device design Min Invas Ther & Allied Technol 2000: 9(2) 67 74 Assessing the corrosion behaviour of Nitinol for minimally-invasive device design R. Venugopalan 1 and C. Trépanier 2 1 Department of Biomedical Engineering,

More information

Effect of Fluoride on Nickel-Titanium and Stainless Steel. Orthodontic Archwires: An In-Vitro Study

Effect of Fluoride on Nickel-Titanium and Stainless Steel. Orthodontic Archwires: An In-Vitro Study Original Article Effect of Fluoride on Nickel-Titanium and Stainless Steel Orthodontic Archwires: An In-Vitro Study Farzin Heravi 1, Mohamad Hadi Moayed 2, Nima Mokhber 3 1 Department of Orthodontics,School

More information

Faculty of Dentistry, National Yang-Ming University, Taipei, Taiwan, ROC.

Faculty of Dentistry, National Yang-Ming University, Taipei, Taiwan, ROC. Original Articles Corrosion behavior of titanium-containing orthodontic archwires in artificial saliva: effects of fluoride ions and plasma immersion ion implantation treatment HER-HSIUNG HUANG 1 CHIA-CHING

More information

Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys

Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys Original Article Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys Masahiro Iijima a ; Kazuhiko Endo b ; Toshihiro Yuasa c ; Hiroki Ohno d ; Kazuo Hayashi e ; Mitsugi

More information

Surface Protection of Niti- Shape Memory Alloy by Colgate Visible White Toothpaste

Surface Protection of Niti- Shape Memory Alloy by Colgate Visible White Toothpaste International Journal of ChemTech Research CODEN (USA): IJCRGG, ISSN: 0974-4290, ISSN(Online):2455-9555 Vol.10 No.5, pp 761-769, 2017 Surface Protection of Niti- Shape Memory Alloy by Colgate Visible White

More information

Department of Industrial Chemistry, Pukyong National University, Busan 48547, Republic of Korea

Department of Industrial Chemistry, Pukyong National University, Busan 48547, Republic of Korea Met. Mater. Int., Vol. 22, No. 5 (2016), pp. 781~788 doi: 10.1007/s12540-016-6124-4 Galvanic Corrosion of Cu Coupled to Au on a Print Circuit Board; Effects of Pretreatment Solution and Etchant Concentration

More information

Materials Science and Engineering C

Materials Science and Engineering C Materials Science and Engineering C 30 (2010) 1112 1117 Contents lists available at ScienceDirect Materials Science and Engineering C journal homepage: www.elsevier.com/locate/msec Biocompatibility and

More information

Surface Characterization of NiTi Superelastic and Shape Memory Alloys After Electrolytic Polishing. 1. Introduction. 2. Experimental. 2.1.

Surface Characterization of NiTi Superelastic and Shape Memory Alloys After Electrolytic Polishing. 1. Introduction. 2. Experimental. 2.1. Materials Research. DOI: http://dx.doi.org/10.1590/1980-5373-mr-2016-0933 Surface Characterization of NiTi Superelastic and Shape Memory Alloys After Electrolytic Polishing Natalia Isabel de Azevedo Lopes

More information

Effects of three different mouthwashes on the surface characteristics of nickel-titanium and Stainless steel archwires in orthodontics

Effects of three different mouthwashes on the surface characteristics of nickel-titanium and Stainless steel archwires in orthodontics Original Research Effects of three different mouthwashes on the surface characteristics of nickel-titanium and Stainless steel archwires in orthodontics Maryam Omidkhoda 1, Maryam Poosti 2, Zoha Sahebnasagh

More information

Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires

Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires Original Article Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires Allahyar Geramy 1, Tabassom Hooshmand 2, Tahura Etezadi 3 1 Professor, Dental Research Center, Dentistry

More information

ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE IN PHYSIOLOGICAL MEDIA OF NITINOL WIRE USED AS BIOIMPLANT

ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE IN PHYSIOLOGICAL MEDIA OF NITINOL WIRE USED AS BIOIMPLANT Digest Journal of Nanomaterials and Biostructures Vol. 8, No. 1, January - March 213, p. 35-41 ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE IN PHYSIOLOGICAL MEDIA OF NITINOL WIRE USED AS BIOIMPLANT DANIELA

More information

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets Original Research Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets Farzin Heravi 1, Nima Mokhber 2, Elnaz Shayan 3 1 Dental Materials Research Center,

More information

History of NiTinol. Ni = Nickel Ti = Titanium N = Naval O = Ordnance L = Laboratory

History of NiTinol. Ni = Nickel Ti = Titanium N = Naval O = Ordnance L = Laboratory History of NiTinol Ni = Nickel Ti = Titanium N = Naval O = Ordnance L = Laboratory NiTinol was discovered in a laboratory of the U.S. Marines in 1962 (US-Naval Ordnance Laboratory). The U.S. Marines wanted

More information

Trisodium Citrate As An Effective Corrosion Inhibitor For Carbon Steel In Chloride Environment

Trisodium Citrate As An Effective Corrosion Inhibitor For Carbon Steel In Chloride Environment _ Trisodium Citrate As An Effective Corrosion Inhibitor For Carbon Steel In Chloride Environment 1 J.Arockia selvi*, 2 P.Kamaraj, 3 M.Arthanareswari, 4 V.Saranya Department of chemistry, Faculty of Engineering

More information

Eosin as Corrosion Inhibitor for Carbon Steel in Well Water

Eosin as Corrosion Inhibitor for Carbon Steel in Well Water The Open Corrosion Journal, 2009, 2, 77-82 77 Eosin as Corrosion Inhibitor for Carbon Steel in Well Water Open Access J. Sathiyabama, Susai Rajendran *, J. Arockia Selvi and J. Jeyasundari Corrosion Research

More information

THE EFFECT OF TOPICAL FLUORIDE AGENTS ON COATED NICKEL-TITANIUM ARCHWIRES. A THESIS IN Oral and Craniofacial Sciences

THE EFFECT OF TOPICAL FLUORIDE AGENTS ON COATED NICKEL-TITANIUM ARCHWIRES. A THESIS IN Oral and Craniofacial Sciences THE EFFECT OF TOPICAL FLUORIDE AGENTS ON COATED NICKEL-TITANIUM ARCHWIRES A THESIS IN Oral and Craniofacial Sciences Presented to the Faculty of the University of Missouri Kansas City in partial fulfillment

More information

The Protection Performance of Polypyrrole Coating Doped with Different Counter Anions for the Corrosion of NiTi Alloy

The Protection Performance of Polypyrrole Coating Doped with Different Counter Anions for the Corrosion of NiTi Alloy 18 The Open Corrosion Journal, 2011, 4, 18-26 Open Access The Protection Performance of Polypyrrole Coating Doped with Different Counter Anions for the Corrosion of NiTi Alloy Kai Qi, Zhenyu Chen, Guoan

More information

Effects of Aluminum and Silicon as Additive Materials for the Zinc Anode in Zn-Air Batteries

Effects of Aluminum and Silicon as Additive Materials for the Zinc Anode in Zn-Air Batteries Journal of the Korean Electrochemical Society Vol. 21, No. 1, 2018, 12-20 https://doi.org/10.5229/jkes.2018.21.1.12 pissn 1229-1935 eissn 2288-9000 Effects of Aluminum and Silicon as Additive Materials

More information

INVITRO CORROSION STUDIES ON NICKEL TITANIUM SUPER ELASTIC ALLOY IN SYNTHETIC URINE IN PRESENCE OF D- GLUCOSE

INVITRO CORROSION STUDIES ON NICKEL TITANIUM SUPER ELASTIC ALLOY IN SYNTHETIC URINE IN PRESENCE OF D- GLUCOSE INVITRO CORROSION STUDIES ON NICKEL TITANIUM SUPER ELASTIC ALLOY IN SYNTHETIC URINE IN PRESENCE OF D- GLUCOSE R.Nagalakshmi 1, J.Sathiyabama 2, I.Ameeth Basha 2*, S.Johnmary 3 1,2* Aarupadai Veedu Institute

More information

Electrochemical Properties of Suprastructures Galvanically Coupled to a Titanium Implant

Electrochemical Properties of Suprastructures Galvanically Coupled to a Titanium Implant Electrochemical Properties of Suprastructures Galvanically Coupled to a Titanium Implant Keun-Taek Oh, Kyoung-Nam Kim Department of Dental Biomaterials and Bioengineering and Research Center for Orofacial

More information

EFFECTS OF TOPICAL FLUORIDE PROPHYLACTIC AGENTS ON THE MECHANICAL PROPERTIES OF ORTHODONTIC NICKEL-TITANIUM CLOSED COIL SPRINGS AND

EFFECTS OF TOPICAL FLUORIDE PROPHYLACTIC AGENTS ON THE MECHANICAL PROPERTIES OF ORTHODONTIC NICKEL-TITANIUM CLOSED COIL SPRINGS AND EFFECTS OF TOPICAL FLUORIDE PROPHYLACTIC AGENTS ON THE MECHANICAL PROPERTIES OF ORTHODONTIC NICKEL-TITANIUM CLOSED COIL SPRINGS AND STAINLESS STEEL CLOSED COIL SPRINGS A THESIS IN Oral and Craniofacial

More information

Ternary inhibitor system containing phosphonate, molybdate and Zn 2+ in corrosion control of carbon steel

Ternary inhibitor system containing phosphonate, molybdate and Zn 2+ in corrosion control of carbon steel Indian Journal of Chemical Technology Vol. 13, May 2006, pp. 275-282 Ternary inhibitor system containing phosphonate, molybdate and Zn 2+ in corrosion control of carbon steel B V Appa Rao* & K Christina

More information

Materials Chemistry and Physics

Materials Chemistry and Physics Materials Chemistry and Physics 115 (2009) 439 443 Contents lists available at ScienceDirect Materials Chemistry and Physics journal homepage: www.elsevier.com/locate/matchemphys Corrosion behavior of

More information

Tahereh Hosseinzadeh Nik 1, Tabassom Hooshmand 2*, Habibeh Farazdaghi 3, Arash Mehrabi 1 and Elham S Emadian Razavi 1

Tahereh Hosseinzadeh Nik 1, Tabassom Hooshmand 2*, Habibeh Farazdaghi 3, Arash Mehrabi 1 and Elham S Emadian Razavi 1 Hosseinzadeh Nik et al. Progress in Orthodontics 2013, 14:48 RESEARCH Open Access Effect of chlorhexidine-containing prophylactic agent on the surface characterization and frictional resistance between

More information

Nickel and Chromium Ions Release from Stainless Steel Bracket Immersed in Fluoridated Mouthwash

Nickel and Chromium Ions Release from Stainless Steel Bracket Immersed in Fluoridated Mouthwash from Stainless Steel Bracket Immersed in Fluoridated Mouthwash Ida Bagus Narmada 1 *, Ria Anbar Baya 2, Thalca Hamid 3 1. Departement of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga,

More information

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Fabio Schemann-Miguel 1, Flávio Cotrim-Ferreira 2, Alessandra Motta Streva 3, Alexander Viégas de

More information

MATERIAL CHARACTERISTICS OF THE ORTHODONTIC ARCHWIRES

MATERIAL CHARACTERISTICS OF THE ORTHODONTIC ARCHWIRES DAAAM INTERNATIONAL SCIENTIFIC BOOK 20 pp. 30-308 CHAPTER 2 MATERIAL CHARACTERISTICS OF THE ORTHODONTIC ARCHWIRES SZUHANEK, C. Abstract Our aim was to investigate the mechanical properties of coated superelastic

More information

Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires

Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires Original Article Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires Višnja Katić a ; Helena Otmačić Ćurković b ; Damir Semenski c ; Gorana Baršić d ;

More information

Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina Stoyanova-Ivanova 2

Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina Stoyanova-Ivanova 2 DOI: 10.18044/Medinform.201741.559 Studying the Effects of Autoclaving Process on Orthodontic Archwires Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina

More information

Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires

Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires Original Article Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires Theodosia N. Bartzela a ; Christiane Senn b ; Andrea Wichelhaus c ABSTRACT Objective: To determine the mechanical

More information

Corrosion inhibition of carbon steel by adipic acid Zn 2+ system

Corrosion inhibition of carbon steel by adipic acid Zn 2+ system Indian Journal of Chemical Technology Vol. 12, July 2005, pp. 472-476 Corrosion inhibition of carbon steel by adipic acid Zn 2+ system G Ruba Helen Florence a, A Noreen Anthony a, J Wilson Sahayaraj b,

More information

Titanium (Ti) is the most widespread

Titanium (Ti) is the most widespread RESEARCH Electrochemical Behavior of Titanium in Artificial Saliva: Influence of ph Savithri Abey, DDS 1 Mathew T. Mathew, PhD 2 Damian J. Lee, DDS, MS 3 Kent L. Knoernschild, DMD, MS 3 Markus A. Wimmer,

More information

The effect of surface treatment and clinical use on friction in NiTi orthodontic wires

The effect of surface treatment and clinical use on friction in NiTi orthodontic wires Dental Materials (2005) 21, 938 945 www.intl.elsevierhealth.com/journals/dema The effect of surface treatment and clinical use on friction in NiTi orthodontic wires Andrea Wichelhaus a, *, Marc Geserick

More information

Mutual Influence of HEDP and SDS - Zn 2+ System on Corrosion Inhibition of Carbon Steel

Mutual Influence of HEDP and SDS - Zn 2+ System on Corrosion Inhibition of Carbon Steel Transactions of the SAEST 40 (2005) 35-39 Transactions of the SAEST Mutual Influence of and SDS - Zn 2+ System on Corrosion Inhibition of Carbon Steel Susai Rajendran 1*, A. John Amalraj 1, J. Wilson Sahayaraj

More information

1 PG & Research Department of Chemistry, G.T.N. Arts College, Dindigul, Tamilnadu, India

1 PG & Research Department of Chemistry, G.T.N. Arts College, Dindigul, Tamilnadu, India ELECTROCHEMICAL AND GRAVIMETRIC STUDY ON THE CORROSION AND CORROSION CONTROL OF CARBON STEEL BY THE BINARY FORMULATION CONTAINING L-GLUTAMIC ACID AND ZINC IONS IN AQUEOUS ENVIRONMENT 1 Dr.A.Sahaya Raja,

More information

Effect of Recycling and Autoclave Sterilization on the Unloading Forces of NiTi Closed-Coil Springs: An In Vitro Study

Effect of Recycling and Autoclave Sterilization on the Unloading Forces of NiTi Closed-Coil Springs: An In Vitro Study Momeni Danaei Sh., et al. J Dent Shiraz Univ Med Sci., Dec. 0; (): 8-90. Original Article Effect of Recycling and Autoclave Sterilization on the Unloading Forces of NiTi Closed-Coil Springs: An In Vitro

More information

A NEW CONCEPT OF MANAGEMENT OF INTRACANAL SEPARATED INSTRUMENT BY ELECTROCHEMICAL DISSOLUTION: A REVIEW

A NEW CONCEPT OF MANAGEMENT OF INTRACANAL SEPARATED INSTRUMENT BY ELECTROCHEMICAL DISSOLUTION: A REVIEW Review Article International Journal of Dental and Health Sciences Volume 02,Issue 06 A NEW CONCEPT OF MANAGEMENT OF INTRACANAL SEPARATED INSTRUMENT BY ELECTROCHEMICAL DISSOLUTION: A REVIEW Akash Agrawal

More information

Key words: Fluoride, Corrosion, Orthodontic archwires,friction,surface topography,fracture resistance.

Key words: Fluoride, Corrosion, Orthodontic archwires,friction,surface topography,fracture resistance. Review Article Effects of Fluoride on Orthodontic Archwires Sharma K, Panda S, Patel K, Gupta G, Gupta S Abstract: Orthodontists often prescribe fluoride based prophylactic agents to prevent white spot

More information

Determination of glucose in human urine by cyclic voltammetry method using gold electrode

Determination of glucose in human urine by cyclic voltammetry method using gold electrode IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Determination of glucose in human urine by cyclic voltammetry method using gold electrode To cite this article: Riyanto and Muh.

More information

of the strain and of the temperature. Superelasticity in Orthodontics was first described for Japanese NiTi, which

of the strain and of the temperature. Superelasticity in Orthodontics was first described for Japanese NiTi, which ISSN: 0975-766X CODEN: IJPTFI Available Online through Research Article www.ijptonline.com SUPERELASTICITY OF NiTi Niha Naveed*, Dr. Sri Rengalakshmi Final Year BDS, Department of Orthodontics, Saveetha

More information

INHIBITIVE EFFECT BY PSIDIUM GUAJAVA LEAF EXTRACT ON THE CORROSION OF Al-Si-Mg (SSM-HPDC) ALLOY IN SIMULATED SEAWATER ENVIRONMENT

INHIBITIVE EFFECT BY PSIDIUM GUAJAVA LEAF EXTRACT ON THE CORROSION OF Al-Si-Mg (SSM-HPDC) ALLOY IN SIMULATED SEAWATER ENVIRONMENT Association of Metallurgical Engineers of Serbia AMES Scientific paper UDC: 669.715:62.193 62.197.3 665.528.277.63 INHIBITIVE EFFECT BY PSIDIUM GUAJAVA LEAF EXTRACT ON THE CORROSION OF Al-Si-Mg (SSM-HPDC)

More information

Synergistic effect of wire bending and salivary ph on surface properties and mechanical properties of orthodontic stainless steel archwires

Synergistic effect of wire bending and salivary ph on surface properties and mechanical properties of orthodontic stainless steel archwires Hobbelink et al. Progress in Orthodontics (2015) 16:37 DOI 10.1186/s40510-015-0109-6 RESEARCH Open Access Synergistic effect of wire bending and salivary ph on surface properties and mechanical properties

More information

Materials Science and Engineering C

Materials Science and Engineering C Materials Science and Engineering C 28 (2008) 1430 1434 Contents lists available at ScienceDirect Materials Science and Engineering C journal homepage: www.elsevier.com/locate/msec Surface structure and

More information

An Accurate Methodology to detect Leaching of Nickel and Chromium Ions in the Initial Phase of Orthodontic Treatment: An in vivo Study

An Accurate Methodology to detect Leaching of Nickel and Chromium Ions in the Initial Phase of Orthodontic Treatment: An in vivo Study JCDP ORIGINAL RESEARCH Leaching 10.5005/jp-journals-10024-1828 of Nickel and Chromium Ions An Accurate Methodology to detect Leaching of Nickel and Chromium Ions in the Initial Phase of Orthodontic Treatment:

More information

Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs: An in-vitro comparative study

Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs: An in-vitro comparative study ORIGINAL ARTICLE Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs: An in-vitro comparative study Gabriele Vidoni, a Giuseppe Perinetti,

More information

Research on Green Compound Corrosion Inhibitors of Carbon Steel. in Natural Seawater

Research on Green Compound Corrosion Inhibitors of Carbon Steel. in Natural Seawater International Conference on Manufacturing Science and Engineering (ICMSE 0) Research on Green Compound Corrosion Inhibitors of Carbon Steel in Natural Seawater Fu Qiang,a and Xiaogang Yang,b.Electric Power

More information

FABRICATION OF POLYMERIC FILMS AND COATINGS ON NICKEL-TITANIUM SHAPE MEMORY ALLOY AND THEIR BIOMEDICAL APPLICATIONS

FABRICATION OF POLYMERIC FILMS AND COATINGS ON NICKEL-TITANIUM SHAPE MEMORY ALLOY AND THEIR BIOMEDICAL APPLICATIONS FABRICATION OF POLYMERIC FILMS AND COATINGS ON NICKEL-TITANIUM SHAPE MEMORY ALLOY AND THEIR BIOMEDICAL APPLICATIONS LI PENGHUI DOCTOR OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG AUGUST 2014 CITY UNIVERSITY

More information

Synergistic effect of NTMP, Zn 2+ and ascorbate in corrosion inhibition of carbon steel

Synergistic effect of NTMP, Zn 2+ and ascorbate in corrosion inhibition of carbon steel Indian Journal of Chemical Technology Vol. 12, November 2005, pp. 629-634 Synergistic effect of NTMP, Zn 2+ and ascorbate in corrosion inhibition of carbon steel B V Appa Rao a, S Srinivasa Rao a & M Sarath

More information

Objectives: The shape memory resulting from the superelasticity and thermoelastic effect

Objectives: The shape memory resulting from the superelasticity and thermoelastic effect www.scielo.br/jaos Transition temperature range of thermally activated nickel-titanium archwires 1 1 1 FREITAS 1 2 1- Department of Orthodontics. Ingá Faculty, Maringá, PR, Brazil. 2- Department of Biomedical

More information

Comparative analysis of various corrosive environmental conditions for NiTi rotary files

Comparative analysis of various corrosive environmental conditions for NiTi rotary files Comparative analysis of various corrosive environmental conditions for NiTi rotary files Comparative analysis of various corrosive environmental conditions for NiTi rotary files Ji-Wan Yum, Jeong-Kil Park,

More information

GAC Archwire Collection

GAC Archwire Collection GAC Archwire Collection All the Metal That Matters Copper to Nickel and All Points In-Between Your choice in archwires is a critical decision in your quest for excellence. GAC has been recognized as a

More information

Plants Polyphenols: An Alternative Source for Green Corrosion Inhibitor

Plants Polyphenols: An Alternative Source for Green Corrosion Inhibitor Plants Polyphenols: An Alternative Source for Green Corrosion Inhibitor Mohd Jain Kassim, Tan Kang Wei 1 Materials and Corrosion Sciences Laboratory, School of Chemical Sciences, Universiti Sains Malaysia,

More information

Ghita Ouaziz 1, 2 and Oumarou Savadogo Introduction

Ghita Ouaziz 1, 2 and Oumarou Savadogo Introduction International Scholarly Research Network ISRN Materials Science Volume 212, Article ID 14624, 1 pages doi:1.542/212/14624 Research Article The Cathodic Breakdown Test to Assess Chromic Acid Anodized Aluminum

More information

Research Article Do Mechanical and Physicochemical Properties of Orthodontic NiTi Wires Remain Stable In Vivo?

Research Article Do Mechanical and Physicochemical Properties of Orthodontic NiTi Wires Remain Stable In Vivo? BioMed Volume 2016, Article ID 5268629, 5 pages http://dx.doi.org/10.1155/2016/5268629 Research Article Do Mechanical and Physicochemical Properties of Orthodontic NiTi Wires Remain Stable In Vivo? MichaB

More information

Corrosion inhibition and biocidal activity of a cationic surfactant

Corrosion inhibition and biocidal activity of a cationic surfactant Indian Journal of Chemical Technology Vol. 16, July 2009, pp. 328-333 Corrosion inhibition and biocidal activity of a cationic surfactant P Shanthy a, P Rengan a, A Thamarai Chelvan b, K Rathika c & S

More information

Presented by Sean Day, Stanley Gelin, Kristin O Connor, Chris Sullivan, and Brian Wilson

Presented by Sean Day, Stanley Gelin, Kristin O Connor, Chris Sullivan, and Brian Wilson Different corrosive effects on hydroxyapatite nanocrystals and amine fluoride-based mouthwashes on dental titanium brackets: a comparative in vitro study Presented by Sean Day, Stanley Gelin, Kristin O

More information

Synergistic effect of Fructose and Zn 2+ in controlling corrosion of carbon steel

Synergistic effect of Fructose and Zn 2+ in controlling corrosion of carbon steel A.LEEMA ROSE 1, A. PETER PASCAL REGIS 2, SUSAI RAJENDRAN 3,4, FELICIA RAJAMMAL SELVA RANI 1, A KRISHNAVENI 5 Scientific paper UDC:620.197.3:664.14 Synergistic effect of Fructose and Zn 2+ in controlling

More information

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION Dental Materials Journal 2015; 34(3): 388 393 Influences of archwire size and ligation method on the force magnitude delivered by nickel-titanium alloy archwires in a simulation of mandibular right lateral

More information

THE EFFECT OF ADDING TiO 2 NANOPARTICLES ON DENTAL AMALGAM PROPERTIES

THE EFFECT OF ADDING TiO 2 NANOPARTICLES ON DENTAL AMALGAM PROPERTIES THE EFFECT OF ADDING TiO 2 NANOPARTICLES ON DENTAL AMALGAM PROPERTIES N. Bahremandi Tolou 1*, M. H. Fathi 1,2, A. Monshi 3, V. S. Mortazavi 4, F. Shirani 4 and M. Mohammadi Sichani 5 * bahremandi.n@gmail.com

More information

Nickel-titanium (NiTi) endodontic files are particularly helpful for successful shaping

Nickel-titanium (NiTi) endodontic files are particularly helpful for successful shaping SEM Observations and Differential Scanning Calorimetric Studies of New and Sterilized Nickel-Titanium Rotary Endodontic Instruments Georgia B. Alexandrou,* Konstantinos Chrissafis, Leonidas P. Vasiliadis,*

More information

Corrosion Resistanne of the [TiN/CrN]n Coatings Deposited on Steel AISI 4140

Corrosion Resistanne of the [TiN/CrN]n Coatings Deposited on Steel AISI 4140 Int. J. Electrochem. Sci., 8 (2013) 10711-10719 International Journal of ELECTROCHEMICAL SCIENCE www.electrochemsci.org Corrosion Resistanne of the [TiN/CrN]n Coatings Deposited on Steel AISI 4140 W. Aperador

More information

Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions

Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions M. Darabara 1, L. Bourithis 1, S. Zinelis 2 & G. D. Papadimitriou 1 1 School of Mining and

More information

RBM dental implants by CST Process Technical Release September 2012

RBM dental implants by CST Process Technical Release September 2012 Page 1 of 7 RBM dental implants by CST Process Technical Release September 2012 Summary Finish Line operates technologically validated RBM (Resorbable Blasting Media) Process, based on its CST (Comprehensive

More information

Corrosion Inhibition of Mild Steel in Sulphuric acid medium by Thio Urea Zn 2+ system

Corrosion Inhibition of Mild Steel in Sulphuric acid medium by Thio Urea Zn 2+ system Corrosion Inhibition of Mild Steel in Sulphuric acid medium by Thio Urea Zn 2+ system Geetha M.B 1 1 Department of Chemistry, St.Michael College of Engineering & Technology, Kalayarkoil 630551, India K.Madhavan

More information

N REPORT DOCUMENTATION PAGE 1/30/2009-1/30/2011. Final 02/23/2011

N REPORT DOCUMENTATION PAGE 1/30/2009-1/30/2011. Final 02/23/2011 REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions,

More information

Effect of Artificial Salvia on Force Values of Two Types of Nickel Titanium Orthodontic

Effect of Artificial Salvia on Force Values of Two Types of Nickel Titanium Orthodontic ISSN: 1812 1217 Effect of Artificial Salvia on Force Values of Two Types of Nickel Titanium Orthodontic Arch Wires Afrah K Al -Hamadani BDS, MSc (Asst Prof.) Enas T Al-Jwary BDS, MSc (Lec.) Dept of Pedod,

More information

R J M E Romanian Journal of Morphology & Embryology

R J M E Romanian Journal of Morphology & Embryology Rom J Morphol Embryol 2015, 56(3):1119 1125 ORIGINAL PAPER R J M E Romanian Journal of Morphology & Embryology http://www.rjme.ro/ Assessment of orthodontic biomaterials cytotoxicity: an in vitro study

More information

Wear of NiTi coatings obtained by thermal spraying

Wear of NiTi coatings obtained by thermal spraying , 06007 (2009) DOI:10.1051/esomat/200906007 Owned by the authors, published by EDP Sciences, 2009 Wear of NiTi coatings obtained by thermal spraying N. Cinca 1a 2 1, I. G. Cano 1, S. Dosta 1, J. M. Guilemany

More information

Angiogenesis of Metal Ions by Components of Dental Gold-silver-palladium Alloys used by Dental Prosthetics in Vitro

Angiogenesis of Metal Ions by Components of Dental Gold-silver-palladium Alloys used by Dental Prosthetics in Vitro J Oral Tissue Engin 2013;11(1):79-84 ORIGINAL ARTICLE Angiogenesis of Metal Ions by Components of Dental Gold-silver-palladium Alloys used by Dental Prosthetics in Vitro Koichi IMAI 1, Kazuhiko SUESE 2,

More information

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System The Loading And Unloading roperties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System Authors: Thomas Mathew MDS Orthodontics, Lecturer, Faculty of Dentistry,

More information

Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study

Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 2005-372X http://dx.doi.org/10.4041/kjod.2012.42.3.129 Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry

More information

Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires

Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires Original Article Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires Takeshi Muguruma a ; Masahiro Iijima b ; William A. Brantley c ; Itaru Mizoguchi d ABSTRACT Objective:

More information

Investigation of adding fluoroapatite nanoparticles on compressive strength and corrosion behaviour of dental amalgams

Investigation of adding fluoroapatite nanoparticles on compressive strength and corrosion behaviour of dental amalgams Processing and Application of Ceramics 6 [4] (2012) 193 199 Investigation of adding fluoroapatite nanoparticles on compressive strength and corrosion behaviour of dental amalgams Fahimeh Mirlohi 1, Ali

More information

Surface Protection of Carbon Steel by Butanesulphonic Acid Zinc Ion System

Surface Protection of Carbon Steel by Butanesulphonic Acid Zinc Ion System Abstract Research Journal of Chemical Sciences ISSN 2231-606X Res.J.Chem. Sci. Surface Protection of Carbon Steel by Butanesulphonic Acid Zinc Ion System Mary Anbarasi C. 1 * and Susai Rajendran 2 1 PG

More information

Biomimetic deposition process of an apatite coating on NiTi shape memory alloy

Biomimetic deposition process of an apatite coating on NiTi shape memory alloy Materials Letters 60 (2006) 3002 3006 www.elsevier.com/locate/matlet Biomimetic deposition process of an apatite coating on NiTi shape memory alloy C.L. Chu a,,y.p.pu b, L.H. Yin b, C.Y. Chung c, K.W.K.

More information

A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems

A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems 10.5005/jp-journals-10015-1102 H ORIGINAL Jyothikiran et RESEARCH al A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems 1 H Jyothikiran,

More information

The effective parameters on the corrosion behavior of dental amalgam

The effective parameters on the corrosion behavior of dental amalgam The effective parameters on the corrosion behavior of dental amalgam Mortazavi V. DDS, MSc 1, Fathi M.H. PhD 2 1 Associate Prof., Dept. of Operative of Dentistry, Dental School, Isfahan University of Medical

More information

The mechanical properties of NiTi and biocompatibility implants in bone of albino rats

The mechanical properties of NiTi and biocompatibility implants in bone of albino rats Journal of Gene c and Environmental Resources Conserva on, 2016, 4(2):75-79. www.jgerc.com The mechanical properties of NiTi and biocompatibility implants in bone of albino rats Siham S. Abdullah 1, Jenan

More information

Effect of Topical Fluoride on Surface of Cast. Titanium and Nickel-Chromium: An In Vitro Study

Effect of Topical Fluoride on Surface of Cast. Titanium and Nickel-Chromium: An In Vitro Study Original Article Effect of Topical Fluoride on Surface of Cast Titanium and Nickel-Chromium: An In Vitro Study Gayatri Sheena Suvarna 1, Ramesh Khandurao Nadiger 2, Omkar Shetty 3 1 Associate Professor,

More information

A New Sacrificial Corrosion Protection Mechanism for High Performance Zinc/Aluminum Flake Coating Systems and Applications

A New Sacrificial Corrosion Protection Mechanism for High Performance Zinc/Aluminum Flake Coating Systems and Applications A New Sacrificial Corrosion Protection Mechanism for High Performance Zinc/Aluminum Flake Coating Systems and Applications Shusaku Ishikawa Senior Technical Manager, Engineering Yuken America Inc. Introduction

More information

Technion, Institute of Technology- Israel

Technion, Institute of Technology- Israel Micro surface Micro surface T.A.G Dental implant surface treatment is a result of extensive experience and research which resulted in obtaining the best biological response. The success and safety of dental

More information

INTRODUCTION TO ULTRASONIC IN-LINE INSPECTION OF CRA PIPELINES. Herbert Willems, Gerhard Kopp NDT Global, Stutensee, GERMANY

INTRODUCTION TO ULTRASONIC IN-LINE INSPECTION OF CRA PIPELINES. Herbert Willems, Gerhard Kopp NDT Global, Stutensee, GERMANY INTRODUCTION TO ULTRASONIC IN-LINE INSPECTION OF CRA PIPELINES Herbert Willems, Gerhard Kopp NDT Global, Stutensee, GERMANY PPSA Seminar, Aberdeen, November 16, 2016 OUTLINE BACKGROUND Application of CRA

More information

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires S1:1 170421 7390 SOLITAIRE Single Pack s OrthoQuest offers the highest quality wires available in the orthodontic industry. Our wires are designed to exact specifications by trained engineers and manufactured

More information

Niobium Wires as Space Holder and Sintering Aid for Porous NiTi**

Niobium Wires as Space Holder and Sintering Aid for Porous NiTi** DOI: 10.1002/adem.201000241 Niobium Wires as Space Holder and Sintering Aid for Porous NiTi** By Ampika Bansiddhi* and David C. Dunand When NiTi powder compacts containing Nb wires are heated above 1 170

More information

Review of Orthodontic Archwires

Review of Orthodontic Archwires Chapter 2 Review of Orthodontic Archwires 2.1 Introduction The archwire, through mechanical interaction with the bracket slots, are designed to move teeth from malocclusion to a preferred dental occlusion.

More information

Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires

Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires ORIGINAL ARTICLE Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires Dayanne Lopes da Silva, a Claudia Trindade Mattos, b Eduardo Franzotti Sant Anna, c Ant^onio

More information

A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial

A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial Original Article A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial Reem Sh. Abdelrahman a ; Kazem S. Al-Nimri b ; Emad F. Al Maaitah c ABSTRACT

More information

Electronic Supplementary Information. High-Yield Bottom-Up Synthesis of 2D Metal Organic Frameworks

Electronic Supplementary Information. High-Yield Bottom-Up Synthesis of 2D Metal Organic Frameworks Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry 2017 Electronic Supplementary Information High-Yield Bottom-Up Synthesis of

More information

Supporting Information. for. Cyclodextrin inhibits zinc corrosion by destabilizing point defect formation. in the oxide layer

Supporting Information. for. Cyclodextrin inhibits zinc corrosion by destabilizing point defect formation. in the oxide layer Supporting Information for Cyclodextrin inhibits zinc corrosion by destabilizing point defect formation in the oxide layer Abdulrahman Altin 1, Maciej Krzywiecki 1, 2, Adnan Sarfraz 1, Cigdem Toparli 1,

More information

Electrophysiology & Neurochemistry Sensor for Stroke Studies

Electrophysiology & Neurochemistry Sensor for Stroke Studies Electrophysiology & Neurochemistry Sensor for Stroke Studies Victor Nekrasov P.I. Professor Patrick J. Rousche Masters Student Peter Tek Neural Engineering Applications Lab UIC Bioengineering Purpose of

More information

Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, , P. R.

Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, , P. R. Electrochemical synthesis of p-type Zn-Doped α-fe 2 O 3 nanotube arrays for photoelectrochemical water splitting Xiaopeng Qi, a,b Guangwei She,* a Meng Wang, a,b Lixuan Mu, a and Wensheng Shi* a a Key

More information

Improving photovoltaic performance of solid-state ZnO/CdTe coreshell. nanorod array solar cells by a thin CdS interfacial layer

Improving photovoltaic performance of solid-state ZnO/CdTe coreshell. nanorod array solar cells by a thin CdS interfacial layer Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry 2014 Supplementary Information of Improving photovoltaic performance of solid-state

More information

SUPPLEMENTARY INFORMATION. Direct Observation of the Local Reaction Environment during the Electrochemical Reduction of CO 2

SUPPLEMENTARY INFORMATION. Direct Observation of the Local Reaction Environment during the Electrochemical Reduction of CO 2 Direct Observation of the Local Reaction Environment during the Electrochemical Reduction of CO 2 Ezra L. Clark 1,2 and Alexis T. Bell* 1,2 1 Joint Center for Artificial Photosynthesis Lawrence Berkeley

More information

Archwires & Accessories

Archwires & Accessories Archwires & Accessories Orthodontic products-catalog 01 55 Archwires and Accessories Summary Archwire Shapes 58 Initialloy 59 BioEdge 60 BioActive 61 Reverse Curve 62 Beta Titanium 62 Stainless Steel Archwires

More information

ORTHODONTIC WIRES. 1. Commercial name: Contour NiTi Memoflex NiTi Cuper NiTi Stainless Steel TMA Archwire Sequence Springs

ORTHODONTIC WIRES. 1. Commercial name: Contour NiTi Memoflex NiTi Cuper NiTi Stainless Steel TMA Archwire Sequence Springs PAGE 1 of 6 1. Commercial name: Contour NiTi Memoflex NiTi Cuper NiTi Stainless Steel TMA Archwire Sequence Springs 2. Manufacturer: Aditek do Brasil Ltda. Address: Cesário Mota, 14 ZIP: 14140-000 - Cravinhos

More information

wiirre e a a n n d d w wiirre e ffo orrms ms

wiirre e a a n n d d w wiirre e ffo orrms ms wire and wire forms wire and wire forms wire and wire forms Leone orthodontic wires are available in a range of alloys and different grades of elasticity and hardness to meet any therapeutic requirements.

More information

Clinpro Glycine Prophy Powder

Clinpro Glycine Prophy Powder Clinpro Glycine Prophy Powder 3M 2016. All Rights Reserved VIDEO 3M 2016. All Rights Reserved 2 Presentation Overview Air Polishing Procedure With Clinpro Glyciene Prophy Powder Use and Efficiency for

More information

Mechanical and Surface Properties of Initial and Working Aesthetic Orthodontic Archwires

Mechanical and Surface Properties of Initial and Working Aesthetic Orthodontic Archwires ANNALS OF DENTISTRY University of Malaya ORIGINAL ARTICLE Mechanical and Surface Properties of Initial and Working Aesthetic Orthodontic Archwires Tang YC 1, Peh XL 1, Zakaria N N 2, Radzi Z 2* 1 Faculty

More information