8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
|
|
- Colleen Willis
- 5 years ago
- Views:
Transcription
1 Report No: L Date: 8/17/ E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L Report Prepared For: Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI Model Number: MB1-2W-A Test: Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Catalog number is MB1-2W-A. Received in working and undamaged condition. No modifications were necessary. Testing Condition: Fixture is tested with no special conditions. Sample Arrival Date: Date of Tests: Seasoning of Sample: 8/9/16 8/15/16-8/17/16 No seasoning was performed in accordance with IESNA LM-79. Equipment List Equipment Used Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02 -- Yokogawa Digital Power Meter WT210 MT-EL06-S1 11/18/16 Xitron Power Analyzer 2503AH MT-EL01 11/30/16 ITECH DC Power Supply IT6122 PSDC-03-S1 11/17/16 Fluke Digital Thermometer 52k/J MT-TP02-GC 11/24/16 LLI Type C Goniophotometer System RMG-C-MKII CD-LL04-GC -- LLI 2M Sphere 2MR97 CD-SN03-S2 -- LLI Spectroradiometer SPR-3000 MT-SC01-S2 Before Use *All Results in accordance to IESNA LM : Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4
2 Report No: L Date: 8/17/ E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: Input Voltage (VAC/60Hz): Input Current (Amp): 0.26 Input Power (W): 2.24 Input Power Factor: 0.71 Current 12V(%): 89% Current 277V(%): N/A Efficacy: 2 Color Rendering Index (CRI): -23 Correlated Color Temperature (K): 1521 Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature ( o C): 25.0 Stabilization Time (Hours): 1:20 Total Operating Time (Hours): 2:25 Off State Power(W): 0.00 Beachside Lighting MB1-2W-A N/A 4.60 FIG. 1 LUMINAIRE *All Results in accordance to IESNA LM : Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4
3 Percent Output Report No: L Date: 8/17/ E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Spectral Power Wavelength(nm) Wavelength W/m 2 nm CRI & CCT x y u' v' CRI CCT 1521 Duv R Values R R R R R R R R R R R R R R Y CIE 1931 Chromaticity Diagram , X *All Results in accordance to IESNA LM : Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4
4 Report No: L Date: 8/17/ E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25 o C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 o C throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(cct) and the color rendering index(cri) for each sample. Ambient temperature is set to 25 o C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 o C throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 14 *All Results in accordance to IESNA LM : Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4
5 DESCRIPTIVE INFORMATION (From Photometric File) IESNA:LM [TEST] L [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 8/17/2016 [MANUFAC] Beachside Lighting [LUMCAT] MB1-2W-A [LUMINAIRE] Pathlight [BALLASTCAT] N/A [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [INPUT] 12VAC, 2.24W [TEST PROCEDURE] IESNA:LM CHARACTERISTICS IES Classification Type IV Longitudinal Classification Very Short Lumens Per Lamp N.A. (absolute) Total Lamp Lumens N.A. (absolute) Luminaire Lumens 5 Downward Total Efficiency N.A. (absolute) Total Luminaire Efficiency N.A. (absolute) Luminaire Efficacy Rating (LER) 2 Total Luminaire Watts 2.24 Ballast Factor 1.00 Upward Waste Light Ratio 0.01 Maximum Candela Maximum Candela Angle 0H 75V Maximum Candela (<90 Degrees Vertical) Maximum Candela Angle (<90 Degrees Vertical) 0H 75V Maximum Candela At 90 Degrees Vertical.104 (2.1% Luminaire Lumens) Maximum Candela from 80 to <90 Degrees Vertical (88.4% Luminaire Lumens) Cutoff Classification (deprecated) N.A. (absolute) Page 1
6 LUMINAIRE CLASSIFICATION SYSTEM (LCS) Lumens % Lamp % Luminaire FL - Front-Low (0-30) < 0.05 N.A. 0.2 FM - Front-Medium (30-60) 1.9 N.A FH - Front-High (60-80) 2.2 N.A FVH - Front-Very High (80-90) 0.3 N.A. 6.3 BL - Back-Low (0-30) < 0.05 N.A. 0.0 BM - Back-Medium (30-60) 0.1 N.A. 2.3 BH - Back-High (60-80) 0.1 N.A. 1.5 BVH - Back-Very High (80-90) < 0.05 N.A. 0.2 UL - Uplight-Low (90-100) < 0.05 N.A. 0.4 UH - Uplight-High ( ) < 0.05 N.A. 1.1 Total 4.6 N.A BUG Rating B0-U1-G0 ZONAL LUMEN SUMMARY Zone % Page 2
7 CANDELA TABULATION Vert. Horizontal Angles Angles Vert. Horizontal Angles Angles Page 3
8 CANDELA TABULATION - (Cont.) Vert. Horizontal Angles Angles Page 4
9 CANDELA TABULATION - (Cont.) Vert. Horizontal Angles Angles Page 5
10 CANDELA TABULATION - (Cont.) Page 6
11 COEFFICIENTS OF UTILIZATION SS Coeff. Of 0.5 Utiliz HS Street Width / Mounting Height FLUX DISTRIBUTION Lumens Percent Of Luminaire Downward Street Side Downward House Side Downward Total Upward Street Side Upward House Side Upward Total Total Flux Page 7
12 POLAR GRAPH Maximum Candela = Located At Horizontal Angle = 0, Vertical Angle = 75 # 1 - Vertical Plane Through Horizontal Angles (0-180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (75) (Through Max. Cd.) Page 8
13 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINANCE House Side Street Side Distance In Units Of Mounting Height Values Based On 1.42 Foot Mounting Height 1/2 Maximum Candela Trace Shown As Dashed Curve (+) = Maximum Candela Point Page 9
14 LUMINAIRE CLASSIFICATION SYSTEM (LCS) GRAPH Luminaire Lumens Uplight Back 0 Front Luminaire Lumens: Front: Low=0.0, Medium=1.9, High=2.2, Very High=0.3 Back: Low=0.0, Medium=0.1, High=0.1, Very High=0.0 Uplight: Low=0.0, High=0.0 BUG Rating : B0-U1-G0 Page 10
Test Report. Report Number: L17083 Date: Nov 28, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L1783 Date: Nov 28, 217 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one Vigilant Area Light Unit manufacturer: Dialight Corporation Unit model number: ALU7BC26-xxxxx-N
More informationTest Report. Report Number: L18055 Date: Jun 27, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L1855 Date: Jun 27, 218 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one High Output High Bay w/25ft cable Unit manufacturer: Dialight Corporation Unit model number:
More informationIES LM79-08 Sphere and Goniometer Test Report
Test results reported for: Customer Reference P/N: 701946-6WXLP2 Device Model: Orb Optronix report: - SLOD002-070 Original issue date: 18 May 2015 Prepared for: Testing performed by: SloanLED CSA GROUP
More informationTest Report. Report Number: L17028 Date: Jul 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L17028 Date: Jul 24, 2017 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Area Light Unit manufacturer: Dialight Corporation Unit model number: ALU5BC23-xxxxx-N
More informationTest Report. Report Number: L17029 Date: Jul 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L17029 Date: Jul 24, 2017 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Area Light Unit manufacturer: Dialight Corporation Unit model number: ALC7BC23-xxxxx-N
More informationREPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G102259484 Date: August 31, 2015 REPORT NO. 102259484CRT-002 TEST OF ONE LED
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101777651 Date: August 14, 2014 REPORT NO. 101777651LAX-001 TEST OF
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
REPORT 28 COMMERCENTRE DRIVE, LAKE FOREST, CA 926 Project No. G67677 Date: June 9, 2 REPORT NO. 67677LAX-2 TEST OF ONE FULL ON AT BEAM ANGLE MODEL NO. RAZOR Q2 ZOOM RENDERED TO ELATION PROFESSIONAL 622
More informationIES LM Test Report
IES LM 79 08 Test Report Test results reported for: B 3 DL report: LEAG002 010 Original issue date: 01 May 2012 Prepared for: Testing performed by: The Leader Leader Mfg., Inc 1003 7th Ave. 1540 Leader
More informationType C Goniometer. Used to measure lamp and luminaire output, efficiency/efficacy, intensity distribution and zonal lumen density
Type C Goniometer Used to measure lamp and luminaire output, efficiency/efficacy, intensity distribution and zonal lumen density Expertise Over 35 years of leadership in light metrology enable Labsphere
More informationMethods of optical measurement for directional light/led-sources and luminaires.
Methods of optical measurement for directional light/led-sources and luminaires. There are several normalized goniometric and other principles to measure the directional light output of LEDs, luminaires
More informationTHE LIGHTING SOLUTION for CONTROL ROOMS and 24/7 MISSION CRITICAL ENVIRONMENTS. Optimizes Performance, Productivity and Health
THE LIGHTING SOLUTION for CONTROL ROOMS and 24/7 MISSION CRITICAL ENVIRONMENTS Optimizes Performance, Productivity and Health DynamicBlu Spectrum Control for Optimal 24/7 Operator Performance, Productivity
More informationLMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps
LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps Description and Technical Specification of the Equipment List of Contents: 0 Introduction...- 3-0.1 Principle...-
More informationLIGHTING LABORATORY TESTING SERVICES EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS V1015W
LIGHTING LABORATORY TESTING SERVICES V1015W EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS ABOUT THE LAB The Energywise Lighting Laboratory is offering complete photometric, electric and thermal testing
More informationFortimo LED Strip Gen3
Strip Gen3 2 ft 2200 lm 1R HV3 Datasheet Fortimo LED Strip Gen3 Fortimo LED Strip systems are ideal for use in designer or miniaturized, slim linear luminaires for architectural applications, which were
More informationWe bring quality to light. LGS 350 Goniophotometer
We bring quality to light. LGS 350 Goniophotometer The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight Accurate determination
More informationFortimo LED Square. Datasheet
LED Square 380 mm 5000 lm HV1 Datasheet Fortimo LED Square Fortimo LED Square systems consist of white light LED modules with square outer dimensions delivering high energy efficiency and high quality
More informationProduct Family Part Number CCT. LUXEON D L130-xxyy003000W21 white
Philips Lumileds IESNA LM-80 Test Report Philips Lumileds IESNA LM-80 Test Report 1. Applicable LUXEON Series part number(s) This IESNA LM-80 Test Report applies to the following LUXEON part numbers: Product
More informationProduct Family Part Number Nominal CCT LUXEON D L W K LUXEON D L W K
Philips Lumileds IESNA LM-80 Test Report Philips Lumileds IESNA LM-80 Test Report 1. Applicable LUXEON Series part number(s) This IESNA LM-80 Test Report applies to the following LUXEON part numbers: Product
More informationWe bring quality to light. LGS 1000 Goniophotometer
We bring quality to light. LGS 1000 Goniophotometer Instrument description Measurement options Spatial radiation patterns Luminous flux integration Specifications Key features at a glance Goniophotometer
More informationAreamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.
Lighting HID NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE RATED FLOODLIGHT Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Pulp and paper mills Processing plants
More informationApplications. Projected Area: 1.9 Sq. Ft. Dimensions in Inches/Millimeters
NEC/CEC: Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Shopping malls Parking lots Sports areas New-car lot lighting Security lighting Industrial process lighting
More informationSENIOR LIVING LIGHTING SOLUTIONS FOR RESIDENTS & STAFF. Improving Health, Wellbeing, Safety & Staff Productivity
SENIOR LIVING LIGHTING SOLUTIONS FOR RESIDENTS & STAFF Improving Health, Wellbeing, Safety & Staff Productivity SENIOR LIVING LIGHTING SOLUTIONS FOR RESIDENTS & STAFF Improving Health, Wellbeing, Safety,
More informationAMS 200. Goniophotometer for small to medium-sized lamps and modules
AMS 200 Goniophotometer for small to medium-sized lamps and modules 02 \\ Equipment and function Ke features at a glance CIE Tpe A goniometer for small to medium-sized lamps and modules High-precision
More informationILLUMINATION SUMMARY. Field A S10 EQUIPMENT LIST FOR AREAS SHOWN GUARANTEED PERFORMANCE. North Tract Arlington County, VA
QTY LOCATION SIZE THIS GRID 1 S1 55' -7' ' 1500W MZ 5 5 0 1 S2.' - ' 1500W MZ 6 6 0 1 S3 55.5' -6' 49.5' 1500W MZ 9 5 4 1 S8 ' - 43.5' 1500W MZ 4 4 0 1 S9 43.5' - 43.5' 1500W MZ 6 6 0 1 S10 43.5' - 43.5'
More informationLED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE
Module ELA G1 SNC Modules ELA ESSENCE Product description Edgelit panel for direct recessed mount and surface or suspended mount with accessories Two luminous flux range variants 2,8 or 3,8 lm For suspended
More informationExperience bright and vivid colors
SLM PW 1204 L13 Gen5 Datasheet Experience bright and vivid colors Fortimo SLM PW 1204 L13 G5 Fortimo LED SLM Gen5 continues to focus on the combination of Quality of Light and performance. By offering
More informationExperience bright and vivid colors
SLM 1208 PW L15 Gen5 Datasheet Experience bright and vivid colors Fortimo LED SLM 1208 lm PW L15 Fortimo LED SLM Gen5 continues to focus on the combination of Quality of Light and performance. By offering
More informationLED Modules. Fortimo LED Line
LED Modules Fortimo LED Line 1ft 1100lm 3R Fortimo LED Line gen 4 will enable you to upgrade your linear LED luminaires to latest high-performance technology while offering the freedom to tune and differentiate
More informationFeatures CONSTANT WATTAGE AUTOTRANSFORMER 1.9 SQ FT Lamp Included 0 MOGUL BASE HIGH PRESSURE SODIUM
GAM671L48I2 250W HPS Flood Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category GAM671L48I2 Appleton/Oz Gedney Floodlight, Mogul Base High Pressure Sodium Lamp; Lamp
More informationSpecification for white LED
Specification for white LED Ergon COB 2530 62W maximum power capability High brightness LED Dimension : 23.85 x 23.85 x 2.35 mm Precondition : JEDEC Level 2a Lead-free reflow soldering application RoHS
More informationEnergy-saving policy and standard research for solid-state lighting in the United States
Interview Energy-saving policy and standard research for solid-state lighting in the United States [Translation from Synthesiology, Vol.2, No.2, p.170-175 (2009)] When Dr. Yoshi Ohno, who engages in the
More informationFit-for-use TL5 lamp. TL5 Essential HE Super 80. Benefits. Features. Application
Lighting Fit-for-use TL5 lamp TL5 Essential HE Super 80 Philips TL5 Essential Super80 is a new fluorescent lamp which provides home users and professional end-users an aesthetic miniaturized lighting solution
More informationPARATHOM PRO LEDspot 111
PARATHOM PRO LEDspot 111 LED reflector lamps AR111 with retrofit pin base Areas of application _ Shops _ Galleries _ Museums _ Shops and exhibition rooms _ Directional light sources Product benefits _
More informationPARATHOM PRO LEDspot 111
PARATHOM PRO LEDspot 111 LED reflector lamps AR111 with retrofit pin base Areas of application _ Shops _ Galleries _ Museums _ Shops and exhibition rooms _ Directional light sources Product benefits _
More informationWHITE PAPER. Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation
Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions
More informationStandards. n Built in accordance with NEMA, ANSI, UL and CSA standards
Drive Isolation 4 3 to 990 kva Applications n For industrial and commercial applications with SCR-controlled adjustable speed motor drives, and AC adjustable frequency or DC drives Specifications n NEMA1
More informationPARATHOM PRO LEDspot 111
PARATHOM PRO LEDspot 111 LED reflector lamps AR111 with retrofit pin base Areas of application _ Shops _ Galleries _ Museums _ Shops and exhibition rooms _ Directional light sources Product benefits _
More informationEfficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation
Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation Hubert Kostal*, Douglas Kreysar, Ronald Rykowski Radiant Imaging, Inc., 22908
More informationLINEAR FLUORESCENT 15
LINEAR FLUORESCENT 15 Advanced technologies and environmental focus have changed the face of ar Fluorescent lighting. From ultra thin and efficient to specialized applications, Halco has your lighting
More informationLIGHT + COLOR Final Report May 1, Introduction
LIGHT + COLOR Final Report May 1, 2016 Introduction The third Illuminating Engineering Society (IES) lighting research symposium, held in Gaithersburg MD in April 2016, took an in depth look at specific
More informationGoniophotometer RiGO 801
Goniophotometer RiGO 801 General specification Model series 1400, 1500, 1800, 2000 2018-03-13 TechnoTeam Bildverarbeitung GmbH Werner-von-Siemens-Straße 5 D-98693 Ilmenau http://www.technoteam.de Table
More informationSolar Illumination Study
Solar Illumination Study INTRODUCTION The angle of the sun in the sky relative to the horizon (vertical angle) changes throughout the day as the sun traverses from east to west. And the angle that the
More informationDefinition and measurement of circadian radiometric quantities
Gall, Dietrich; Bieske, Karin : Definition and measurement of circadian radiometric quantities Inhalt identisch mit: Light and health - non-visual effects : proceedings of the CIE symposium 4 : 3 September
More informationA novel method to set up and calibrate goniophotometer
A novel method to set up and calibrate goniophotometer Ziyi Wu University of Arizona (520) 258-8094 December 4 2016 Abstract In this report, I described a new method to set up and calibrate goniophotometer.
More informationLighting in Flux. Peter R. Boyce PhD.
Lighting in Flux Peter R. Boyce PhD. The Past For many decades, general lighting practice has been founded on: Two objectives good visual performance without discomfort Two systems of measurement photometry
More informationLINESCAPES SYSTEM. Made in Italy
LINESCAPES SYSTEM LINESCAPES SYSTEM Made in Italy 03 Linescapes is a modular system that is completely changing the approach to high performance diffused direct and indirect lighting. The singular modules
More informationEXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS
EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS It is generally accepted that proper use of indoor tanning methods may be safer for the tanner than the uncontrolled environment of outdoor tanning. However,
More informationSafeguard a hygienic environment
Safeguard a hygienic environment New Philips MASTER Actinic BL lamps - the most effective way to eliminate insects Hygiene and food safety are crucial in professional applications such as restaurants,
More information2. A light fixture mounted above the sign face may be installed with its bottom opening tilted toward the sign face, provided:
Section 20.132.090 Sign illumination. A. General. No temporary sign may be illuminated. No sign located in a residential zone may be illuminated, except that on parcels two (2) acres in size or greater,
More informationNOVEMBER 7, 2017 STREET LIGHT MASTER PLAN EXISTING CONDITIONS REPORT
NOVEMBER 7, 2017 STREET LIGHT MASTER PLAN EXISTING CONDITIONS REPORT 1 AGENDA EDUCATION & METHODOLOGY RESULTS POLICIES 2 WHAT WAS STUDIED? LOCATIONS 18 study areas chosen by Committee and City staff MEASUREMENTS
More informationJEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA
JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA TYPICAL APPLICATIONS All general loads, indoors or outdoors, including lighting, industrial & commercial Schools Hospitals Factories Office
More informationKRUT SYSTEMS LLC PRODUCT CATALOG
KRUT SYSTEMS LLC PRODUCT CATALOG www.krut-led.com KRUT SYSTEMS LLC COMPANY PROFILE Krut Systems LLC is an LED lighting company catering to a wide range of industrial and commercial customers, and customers
More informationDynamic Muscle Recorder
Dynamic Muscle Recorder Team 17 By: Michael Petrowicz Farrukh Rahman James Porteus Client: Biomedical Engineering Department Dr. Enderle Executive Summary The biomedical department requires a lab setup
More information8/20/ Identify the functions of common ECG machines. 3.3 Explain how each ECG machine control is used. 3.4 Recognize common electrodes.
1 2 Electrocardiography for Healthcare Professionals Chapter 3: The Electrocardiograph Learning Outcomes 3.1 Identify three types of leads, and explain how each is recorded. 3.2 Identify the functions
More informationAgilent 1220 Infinity LC System Performance Specifications
IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance
More informationDevelopment of an Electronic Glove with Voice Output for Finger Posture Recognition
Development of an Electronic Glove with Voice Output for Finger Posture Recognition F. Wong*, E. H. Loh, P. Y. Lim, R. R. Porle, R. Chin, K. Teo and K. A. Mohamad Faculty of Engineering, Universiti Malaysia
More informationCOLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES
FOR XMI MINERAL INSULATED (MI) HEATING CABLES PRODUCT OVERVIEW XMI with standard MI cold lead and Type X connector MI cable heated section PRODUCT OVERVIEW XMI with PyroFLX cold lead and Type K connector
More informationSome Thoughts on Calibrating LaModel
Some Thoughts on Calibrating LaModel Dr. Keith A. Heasley Professor Department of Mining Engineering West Virginia University Introduction Recent mine collapses and pillar failures have highlighted hli
More informationMS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type
ABB MS132-6.3 Manual Motor Starter General Information Extended Product Type Product ID MS132-6.3 1SAM350000R1009 EAN 4013614400094 Catalog Description Long Description MS132-6.3 Manual Motor Starter The
More informationMarket Acceptance Of Screwbase Compact Fluorescent Lamps (CFLs)
Market Acceptance Of Screwbase Compact Fluorescent Lamps (CFLs) Lighting Research Center Rensselaer Polytechnic Institute Sponsors: US Environmental Protection Agency US Department of Energy February 2004
More informationDEFORMATION TRANSDUCER CALIBRATOR OPERATION
The Calibration Company DEFORMATION TRANSDUCER CALIBRATOR OPERATION December 2011 doc#: EMS10 rev: 2 1 DEFORMATION TRANSDUCER CALIBRATOR OPERATION 1.1 Introduction The deformation transducer calibrator
More informationCommonwealth of Pennsylvania PA Test Method No. 423 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for
Commonwealth of Pennsylvania PA Test Method No. 423 Department of Transportation 10 Pages 1. SCOPE LABORATORY TESTING SECTION Method of Test for RETRO-DIRECTIVE REFLECTIVITY OF REFLECTIVE MATERIALS 1.1
More informationVerified. Learning. Their. Candidate. to Gauge. Candidate Course. Page 1
Coach s Review Assessment of Completion Module 1 Light Lighting Overview Cidate understs the WIIFM, How to Gauge Their Progress the Course Duration. Cidate understs the Principles, Practices, ett al of
More informationall cross-trainers are created
The Arc Training R R www.cybexintl.com all cross-trainers are created Having the Arc Training Advantage means having the only true cross-trainer on the market today. Cross-training in sports and fitness
More informationSupporting Information
Supporting Information Over cd/a Efficient Green Quantum Dot Electroluminescent Device Comprising Uniquely Large-Sized Quantum Dot Ki-Heon Lee, Jeong-Hoon Lee, Hee-Don Kang, Byoungnam Park, Yongwoo Kwon,
More informationMS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type
ABB Manual Motor Starter General Information Extended Product Type Product ID 1SAM250000R1008 EAN 4013614320316 Catalog Description Long Description Manual Motor Starter The manual motor starter (also
More informationCerus P-Series General Specifications Section 15172
Cerus P-Series s Section 15172 Variable Frequency Drives PART 1-GENERAL 1.01 SECTION INCLUDES A. Variable Frequency Drive(VFD) 1.02 RELATED SECTIONS A. Section 16195 1.03 REFERENCES A. NEMA250 B. EN 50178
More informationCP116. Mixed-Color LED Lighting with Circadian Benefits
Mixed-Color LED Lighting with Circadian Benefits Y. J. Tam, V. Kalavally, J. Parkkinen Department of Electrical and Computer Systems Engineering, School of Engineering, Monash University, Jalan Lagoon
More informationUnit 1: Fitness for Sport and Exercise. Fitness Testing
Unit 1: Fitness for Sport and Exercise Fitness Testing Importance of fitness testing Gives baseline data for monitoring/improving performance Can design training programmes based on test results and determine
More informationSign Retroreflectivity A Minnesota Toolkit
Sign Retroreflectivity A Minnesota Toolkit Mike Marti, Primary Author SRF Consulting Group June 2010 Research Project Final Report #2010RIC02 VISUAL NIGHTTIME INSPECTION Method Description: The retroreflectivity
More informationMS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type
ABB Manual Motor Starter Generell informasjon Extended Product Type Product ID 1SAM451000R1015 EAN 401614486098 Catalog Description Long Description Manual Motor Starter MS165 is a compact and powerful
More information1. Introduction. 2. API 5.7 Testing Protocol for Differential Pressure Flow Measurement Devices
Testing the Wafer V-Cone Flowmeters in accordance with API 5.7 Testing Protocol for Differential Pressure Flow Measurement Devices in the CEESI Colorado Test Facility Dr R.J.W.Peters Flow Measurement Technology
More informationKeylock switches for PCB
lock switch for PCB General data lock switch for PCB mounting. Matching with the RS 76 full-travel keyswitch and the RF 15 and RF 19 short-travel keyswitch. Content lock switch IP5, MICROMEC - 18 lock
More information9 TESTS TP4 SOLAR PERGOLAS
9 TESTS of TP4 SOLAR PERGOLAS Concentrated test report on TP4-enersol PV, TD and hybrid functions Athens May 1 215 Detailed graphs shown in.ppt and.pdf A) TP4-PV in East-West direction with solar tracking
More informationColour Fitting Formulae Used for Predicting Colour Quality of Light Sources
Óbuda University e-bulletin Vol. 3, No. 1, 01 Colour Fitting Formulae Used for Predicting Colour Quality of Light Sources Ferenc Szabó Virtual Environments and Imaging Technologies Research Laboratory,
More informationPerceptual Learning of Categorical Colour Constancy, and the Role of Illuminant Familiarity
Perceptual Learning of Categorical Colour Constancy, and the Role of Illuminant Familiarity J. A. Richardson and I. Davies Department of Psychology, University of Surrey, Guildford GU2 5XH, Surrey, United
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.
More informationLED Lighting and the AMA. Dr. Ronald B. Gibbons Director Center for Infrastructure-Based Safety Systems
LED Lighting and the AMA Dr. Ronald B. Gibbons Director Center for Infrastructure-Based Safety Systems Health Impacts and Subjective Color Circadian rhythm, hormone secretion: The hormones responsible
More informationTechnical Data Sheet SONOFLOW CO.55 V1.0
Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a
More informationInstruction Manual No A. Goniometer PS-2138, PS-2137
Instruction Manual No. 012-08904A Goniometer PS-2138, PS-2137 Goniometer Model No. PS-2138 Contents Introduction......................................................... 3 Probe Mounting......................................................
More informationPreferable illuminance under LED lighting for migraineurs aiming to relax
Preferable illuminance under LED lighting for migraineurs aiming to relax Akari Kagimoto 1, Shino Okuda 2, Muneto Tatsumoto 3, Katsunori Okajima 4, Koichi Hirata 3 1 Graduate School of Human Life and Science,
More informationSets: 3 Time: 30 seconds; ideally performed during cool-down; dynamic stretching for warm-up
Dan Christoffer, EdD, ATC, ATR Mayo Clinic Sports Medicine Charlton LC 200 First Street SW Rochester, MN 55905 Email: christoffer.daniel@mayo.edu https://sportsmedicine.mayoclinic.org 1. Sleeper Stretch
More informationHigher National Unit specification: general information
Higher National Unit specification: general information Unit code: H1S3 34 Superclass: MD Publication date: July 2012 Source: Scottish Qualifications Authority Version: 01 Unit purpose This Unit is designed
More informationHuman Centric Lighting needs new quantities for light intensity
Human Centric Lighting needs new quantities for light intensity Luc Schlangen Lighting Europe / Philips Lighting Research Light + Building, Frankfurt, March 15 th 2016 Luc.Schlangen@Philips.com Light for
More informationPara-Karate Functional Testing Manual for the European Championships
Para-Karate Functional Testing Manual for the European Championships Ivan Vivaracho, Classifier of Para-Karate WKF / EKF Karl Michael Schölz, WKF Chairman Para-Karate Commission 1 The classification session
More informationRe: ENSC 370 Project Gerbil Functional Specifications
Simon Fraser University Burnaby, BC V5A 1S6 trac-tech@sfu.ca February, 16, 1999 Dr. Andrew Rawicz School of Engineering Science Simon Fraser University Burnaby, BC V5A 1S6 Re: ENSC 370 Project Gerbil Functional
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationHuman Centric Lighting
Human Centric Lighting Daylight Related Metrics as prerequisite for assessment of light quality and for lighting design Dieter Lang OSRAM GmbH Light Affects Humans Light is Vision Brightness Information
More informationTAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM
TABLE OF CONTENTS TITLE PAGE # PURPOSE / INTRODUCTION / SCOPE 1, 2 ROLES AND RESPONSIBILITIES 2 EMPLOYEE TRAINING 3 ENGINEERING CONTROLS 4 NOISE EXPOSURE EVALUATION 4 SIGNAGE / POSTING 4-5 AUDIOMETRIC
More informationSeattle LED Adaptive Lighting Study
May 29, 2014 REPORT #E14-286 Seattle LED Adaptive Lighting Study Prepared by: Clanton & Associates, Inc. 4699 Nautilus Ct. So. #102 Boulder, CO 80301 Northwest Energy Efficiency Alliance PHONE 503-688-5400
More informationAcceptance testing of a large aperture dynamic wavefront sensor
Acceptance testing of a large aperture dynamic wavefront sensor David J. Fischer*, Alan Wertheimer, Laurie Hill Eastman Kodak Company, 1447 St. Paul St, Rochester, NY 14653 ABSTRACT A large aperture dynamic
More informationSearching for Fluorescent Colored Highway Signs: Bottom-Up versus Top-Down Mechanisms
Searching for Fluorescent Colored Highway Signs: Bottom-Up versus Top-Down Mechanisms Frank Schieber Heimstra Human Factors Laboratories University of South Dakota Vermillion, SD 57069 schieber@usd.edu
More informationCertificate of Accreditation to ISO/IEC 17025:2005
United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200454-0 National Standards of Puerto Rico Rio Piedras,
More informationSMART EquiTest. Physical Dimensions. Electrical Characteristics. Components. Performance Characteristics. Accessories Included
Balance Manager Systems Technical Specifications SMART EquiTest Physical Dimensions (W x D x H) in cm Assembled dimensions 53 x 61* x 94 135 x 155* x 239 Base 53 x 61 x 6 135 x 155 x 15 System cart 25
More informationDECEMBER 21, 2007 TEST REPORT # REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF
DECEMBER 21, 2007 TEST REPORT #207814 REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF8-025-05.0-L-DV SAMTEC, INC. APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR
More informationS202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.
ABB Miniature Circuit Breaker - S00MUC - P - K - ampere General Information Extended Product Type Product ID S0M-KUC CDS7061R077 EAN 4013614433146 Catalog Description Long Description Miniature Circuit
More informationInput Load (ma) Typ.
1. Features Wide 2 : 1 Input Range Low Ripple And Noise Input / Output Isolation 1.5K Vdc Or K Vdc 100% Burn-In Input - Filter Custom Design Available Net Weight : 12 g / g Typical RoHS Converter Certified
More informationHeinrich Berg. TestLab PV Modules Fraunhofer-Institute for Solar Energy Systems ISE in Freiburg. FUE14260
FRAUNHOFER-INSTITUTE FOR SOLAR ENERGY SYSTEMS, ISE REPORT FUE14260 Mechanical load test on PV-Modules with 0 and 20 inclination in combination with PowAR snap S mounting system from supplier ARaymond Energies
More information