IES LM Test Report

Size: px
Start display at page:

Download "IES LM Test Report"

Transcription

1 IES LM Test Report Test results reported for: B 3 DL report: LEAG Original issue date: 01 May 2012 Prepared for: Testing performed by: The Leader Leader Mfg., Inc th Ave Leader International Drive Kirkland, WA Port Orchard, WA Attn: Rick Flaherty rick@theleader.com (360) Test report prepared by: Test report approved by: Aaron Miller Laboratory Manager, Test and Measurement Services David Rush Director, Test and Measurement Services in full without permission of. Page 1 of 9

2 Report:LEAG TG 1.0 Description of test sample Orb test sample identificaton: LEAG Manufacturer specifications: Manufacturer: Leader Manufacturing Voltage (V): 120VAC Part number: B 3 DL Test Current (ma): Model Number: Wattage (W): Description: T8 LED Frequency (Hz): 60 Dimmable: Lamp Mounted on Goniometer as Tested Part number: B 3 DL φ θ Device under test as viewed from the position of the spectrometer. DUT is positioned at angle Φ=0, Θ=0 as defined in the graphic below. The device is rotated from Θ= 0 to Θ=+90 in 2.5 increments and from Φ=0 to Φ=337.5 in 22.5 increments. 2.0 Scope of testing Photometric and electrical testing in accordance with IES LM IES Approved Method for the Electrical and Photometric Measurements of Solid State Lighting Products. All measuremets are made using the goniometer spectroradiometer test method. in full without permission of. Page 2 of 9

3 Report:LEAG TG 2.1 Test protocol and data reduction 1. Data is reported for the 380nm to 800nm spectral range with a 1 nm resolution. 2. A spectral noise reduction algorithm is applied to the raw spectrometer counts to reduce the effects of sensor dark current. 3. The lamp is measured on a type C goniometer in the horizontal orientation. 3.0 Measurement Coordinates for Horizontal Type C Spectral Goniometer in full without permission of. Page 3 of 9

4 Report:LEAG TG 3.0 Results Goniometer Measurements Test Conditions Optical Measurements Test Date: 26 Apr 12 Theta Minimum: 0.0 ± 0.10 Method: goniometer spectroradiometer Theta Maximum: ± 0.10 x axis Alignment: 0.0 ± m Theta Step Size: 2.5 ± 0.10 y axis Alignment: 0.0 ± m Phi Minimum: 0.0 ± 0.10 z axis Alignment: 1 ± m Phi Maximum: ± 0.10 Phi Step Size: 22.5 ± 0.10 Total Integrated Luminous Flux (lm): Chromaticity Coordinates Luminous Efficacy (lm/w): Cx: Correlated Color Temperature CCT (K): 4447 Cy: Color Rendering Index CRI, Ra: 79 u: R9: 8.7 v: Color Purity (%): u': Dominant Wavelength(nm): v': Total Integrated Radiometric Flux (W): Duv: Peak Wavelength (nm): Δu'v': Electrical Measurements Thermal Measurements Active Power(W): Average Voltage(V): * Apparent Power (W): Average Current (A): Power Factor: 0.96 Frequency (Hz): 60.1 * Set point Ambient Temperature ( C): Ambient Humidity (%RH): Sample Temperature ( C): in full without permission of. Page 4 of 9

5 Report:LEAG TG 4.0 Charts 1.20E 03 Spectral Irradiance (θ=45, Φ=0) Spectral Irradiance (W/m 2 *nm) 1.00E E E E E E Wavelength (nm) 6.00E 01 Spectral Illuminance (θ=45, Φ=0) Spectral Illuminance (lm/m 2 /nm) 5.00E E E E E E Wavelength (nm) in full without permission of. Page 5 of 9

6 Report:LEAG TG 5.0 Candela Plots 80 Luminous Intensity (cd) vs Angle (θ) *2 Luminous intensity (cd) θ (degrees) in full without permission of. Page 6 of 9

7 Report:LEAG TG 6.0 Zonal Lumen Summary Zonal Lumen Summary Zone Lumens % Lamp % Luminaire % 25.40% 58.90% 21.70% 16.00% 13.00% 80.50% 19.30% 99.80% 11.70% 25.50% 59.00% 21.70% 16.00% 13.00% 80.70% 19.30% % Lumens Per Zone Zone Lumens % Total Zone Lumens % Total % 2.1% 9.6% 13.8% 18.6% % 4.4% 3.8% 3.1% 2.2% % 10.5% 6.1% 5.1% % 7.0 Illuminance Plots in full without permission of. Page 7 of 9

8 Report:LEAG TG 8.0 Chromaticity Diagram CIE1931 Chromaticity Diagram Plankian Average 45 in full without permission of. Page 8 of 9

9 Report:LEAG TG 9.0 Equipment and Reference Standard Description of Lamp Standard Operating Operating current Lamp standard type voltage (VDC) (A) Watts (W) Illuminance (lux) Calibration date Tungsten Halogen /05/2011 Name of calibration lab Gamma Scientific Lamp Calibration Chain: Irradiance measurements are traceable to NIST through a 2nd generation lamp of known Irradiance maintained at. The calibration chain is given below. Generation Standard Report/File Number Calibration Date Description 1 s/n F 626 NIST# 844/ /3/2011 NIST 1000W standard lamp Test Instrumentation Item Description /use Manufacturer Model Serial# Calibration due 2 Axis Type C Goniometer CA at use Spectroradiometer SP Mar 12 DC Power Supply Kikusui PCR500M RB Digital Power Meter Yokogawa L Mar Additional Information END OF REPORT in full without permission of. Page 9 of 9

IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report Test results reported for: Customer Reference P/N: 701946-6WXLP2 Device Model: Orb Optronix report: - SLOD002-070 Original issue date: 18 May 2015 Prepared for: Testing performed by: SloanLED CSA GROUP

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L061606201 Date: 8/17/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061606201 Report Prepared For: Beachside Lighting 905 Kalanianaole

More information

Test Report. Report Number: L17083 Date: Nov 28, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L17083 Date: Nov 28, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1783 Date: Nov 28, 217 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one Vigilant Area Light Unit manufacturer: Dialight Corporation Unit model number: ALU7BC26-xxxxx-N

More information

Test Report. Report Number: L18055 Date: Jun 27, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L18055 Date: Jun 27, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1855 Date: Jun 27, 218 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one High Output High Bay w/25ft cable Unit manufacturer: Dialight Corporation Unit model number:

More information

Test Report. Report Number: L17028 Date: Jul 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L17028 Date: Jul 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L17028 Date: Jul 24, 2017 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Area Light Unit manufacturer: Dialight Corporation Unit model number: ALU5BC23-xxxxx-N

More information

Test Report. Report Number: L17029 Date: Jul 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L17029 Date: Jul 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L17029 Date: Jul 24, 2017 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Area Light Unit manufacturer: Dialight Corporation Unit model number: ALC7BC23-xxxxx-N

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 28 COMMERCENTRE DRIVE, LAKE FOREST, CA 926 Project No. G67677 Date: June 9, 2 REPORT NO. 67677LAX-2 TEST OF ONE FULL ON AT BEAM ANGLE MODEL NO. RAZOR Q2 ZOOM RENDERED TO ELATION PROFESSIONAL 622

More information

Type C Goniometer. Used to measure lamp and luminaire output, efficiency/efficacy, intensity distribution and zonal lumen density

Type C Goniometer. Used to measure lamp and luminaire output, efficiency/efficacy, intensity distribution and zonal lumen density Type C Goniometer Used to measure lamp and luminaire output, efficiency/efficacy, intensity distribution and zonal lumen density Expertise Over 35 years of leadership in light metrology enable Labsphere

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G102259484 Date: August 31, 2015 REPORT NO. 102259484CRT-002 TEST OF ONE LED

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101777651 Date: August 14, 2014 REPORT NO. 101777651LAX-001 TEST OF

More information

We bring quality to light. LGS 350 Goniophotometer

We bring quality to light. LGS 350 Goniophotometer We bring quality to light. LGS 350 Goniophotometer The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight Accurate determination

More information

We bring quality to light. LGS 1000 Goniophotometer

We bring quality to light. LGS 1000 Goniophotometer We bring quality to light. LGS 1000 Goniophotometer Instrument description Measurement options Spatial radiation patterns Luminous flux integration Specifications Key features at a glance Goniophotometer

More information

Fortimo LED Square. Datasheet

Fortimo LED Square. Datasheet LED Square 380 mm 5000 lm HV1 Datasheet Fortimo LED Square Fortimo LED Square systems consist of white light LED modules with square outer dimensions delivering high energy efficiency and high quality

More information

LIGHTING LABORATORY TESTING SERVICES EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS V1015W

LIGHTING LABORATORY TESTING SERVICES EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS V1015W LIGHTING LABORATORY TESTING SERVICES V1015W EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS ABOUT THE LAB The Energywise Lighting Laboratory is offering complete photometric, electric and thermal testing

More information

Specification for white LED

Specification for white LED Specification for white LED Ergon COB 2530 62W maximum power capability High brightness LED Dimension : 23.85 x 23.85 x 2.35 mm Precondition : JEDEC Level 2a Lead-free reflow soldering application RoHS

More information

Product Family Part Number Nominal CCT LUXEON D L W K LUXEON D L W K

Product Family Part Number Nominal CCT LUXEON D L W K LUXEON D L W K Philips Lumileds IESNA LM-80 Test Report Philips Lumileds IESNA LM-80 Test Report 1. Applicable LUXEON Series part number(s) This IESNA LM-80 Test Report applies to the following LUXEON part numbers: Product

More information

Fortimo LED Strip Gen3

Fortimo LED Strip Gen3 Strip Gen3 2 ft 2200 lm 1R HV3 Datasheet Fortimo LED Strip Gen3 Fortimo LED Strip systems are ideal for use in designer or miniaturized, slim linear luminaires for architectural applications, which were

More information

Product Family Part Number CCT. LUXEON D L130-xxyy003000W21 white

Product Family Part Number CCT. LUXEON D L130-xxyy003000W21 white Philips Lumileds IESNA LM-80 Test Report Philips Lumileds IESNA LM-80 Test Report 1. Applicable LUXEON Series part number(s) This IESNA LM-80 Test Report applies to the following LUXEON part numbers: Product

More information

LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps

LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps Description and Technical Specification of the Equipment List of Contents: 0 Introduction...- 3-0.1 Principle...-

More information

THE LIGHTING SOLUTION for CONTROL ROOMS and 24/7 MISSION CRITICAL ENVIRONMENTS. Optimizes Performance, Productivity and Health

THE LIGHTING SOLUTION for CONTROL ROOMS and 24/7 MISSION CRITICAL ENVIRONMENTS. Optimizes Performance, Productivity and Health THE LIGHTING SOLUTION for CONTROL ROOMS and 24/7 MISSION CRITICAL ENVIRONMENTS Optimizes Performance, Productivity and Health DynamicBlu Spectrum Control for Optimal 24/7 Operator Performance, Productivity

More information

Methods of optical measurement for directional light/led-sources and luminaires.

Methods of optical measurement for directional light/led-sources and luminaires. Methods of optical measurement for directional light/led-sources and luminaires. There are several normalized goniometric and other principles to measure the directional light output of LEDs, luminaires

More information

LED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE

LED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE Module ELA G1 SNC Modules ELA ESSENCE Product description Edgelit panel for direct recessed mount and surface or suspended mount with accessories Two luminous flux range variants 2,8 or 3,8 lm For suspended

More information

Commonwealth of Pennsylvania PA Test Method No. 423 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Commonwealth of Pennsylvania PA Test Method No. 423 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for Commonwealth of Pennsylvania PA Test Method No. 423 Department of Transportation 10 Pages 1. SCOPE LABORATORY TESTING SECTION Method of Test for RETRO-DIRECTIVE REFLECTIVITY OF REFLECTIVE MATERIALS 1.1

More information

PARATHOM PRO LEDspot 111

PARATHOM PRO LEDspot 111 PARATHOM PRO LEDspot 111 LED reflector lamps AR111 with retrofit pin base Areas of application _ Shops _ Galleries _ Museums _ Shops and exhibition rooms _ Directional light sources Product benefits _

More information

Experience bright and vivid colors

Experience bright and vivid colors SLM PW 1204 L13 Gen5 Datasheet Experience bright and vivid colors Fortimo SLM PW 1204 L13 G5 Fortimo LED SLM Gen5 continues to focus on the combination of Quality of Light and performance. By offering

More information

PARATHOM PRO LEDspot 111

PARATHOM PRO LEDspot 111 PARATHOM PRO LEDspot 111 LED reflector lamps AR111 with retrofit pin base Areas of application _ Shops _ Galleries _ Museums _ Shops and exhibition rooms _ Directional light sources Product benefits _

More information

Experience bright and vivid colors

Experience bright and vivid colors SLM 1208 PW L15 Gen5 Datasheet Experience bright and vivid colors Fortimo LED SLM 1208 lm PW L15 Fortimo LED SLM Gen5 continues to focus on the combination of Quality of Light and performance. By offering

More information

PARATHOM PRO LEDspot 111

PARATHOM PRO LEDspot 111 PARATHOM PRO LEDspot 111 LED reflector lamps AR111 with retrofit pin base Areas of application _ Shops _ Galleries _ Museums _ Shops and exhibition rooms _ Directional light sources Product benefits _

More information

AMS 200. Goniophotometer for small to medium-sized lamps and modules

AMS 200. Goniophotometer for small to medium-sized lamps and modules AMS 200 Goniophotometer for small to medium-sized lamps and modules 02 \\ Equipment and function Ke features at a glance CIE Tpe A goniometer for small to medium-sized lamps and modules High-precision

More information

LED Modules. Fortimo LED Line

LED Modules. Fortimo LED Line LED Modules Fortimo LED Line 1ft 1100lm 3R Fortimo LED Line gen 4 will enable you to upgrade your linear LED luminaires to latest high-performance technology while offering the freedom to tune and differentiate

More information

CP116. Mixed-Color LED Lighting with Circadian Benefits

CP116. Mixed-Color LED Lighting with Circadian Benefits Mixed-Color LED Lighting with Circadian Benefits Y. J. Tam, V. Kalavally, J. Parkkinen Department of Electrical and Computer Systems Engineering, School of Engineering, Monash University, Jalan Lagoon

More information

PARATHOM PRO LEDspot 111

PARATHOM PRO LEDspot 111 PARATHOM PRO LEDspot 111 LED reflector lamps AR111 with retrofit pin base Areas of application Shops Galleries Museums Shops and exhibition rooms Directional light sources Product benefits Very low energy

More information

Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation

Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation Hubert Kostal*, Douglas Kreysar, Ronald Rykowski Radiant Imaging, Inc., 22908

More information

SENIOR LIVING LIGHTING SOLUTIONS FOR RESIDENTS & STAFF. Improving Health, Wellbeing, Safety & Staff Productivity

SENIOR LIVING LIGHTING SOLUTIONS FOR RESIDENTS & STAFF. Improving Health, Wellbeing, Safety & Staff Productivity SENIOR LIVING LIGHTING SOLUTIONS FOR RESIDENTS & STAFF Improving Health, Wellbeing, Safety & Staff Productivity SENIOR LIVING LIGHTING SOLUTIONS FOR RESIDENTS & STAFF Improving Health, Wellbeing, Safety,

More information

LIGHT + COLOR Final Report May 1, Introduction

LIGHT + COLOR Final Report May 1, Introduction LIGHT + COLOR Final Report May 1, 2016 Introduction The third Illuminating Engineering Society (IES) lighting research symposium, held in Gaithersburg MD in April 2016, took an in depth look at specific

More information

WHITE PAPER. Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation

WHITE PAPER. Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions

More information

Fit-for-use TL5 lamp. TL5 Essential HE Super 80. Benefits. Features. Application

Fit-for-use TL5 lamp. TL5 Essential HE Super 80. Benefits. Features. Application Lighting Fit-for-use TL5 lamp TL5 Essential HE Super 80 Philips TL5 Essential Super80 is a new fluorescent lamp which provides home users and professional end-users an aesthetic miniaturized lighting solution

More information

Noninvasive Blood Glucose Analysis using Near Infrared Absorption Spectroscopy. Abstract

Noninvasive Blood Glucose Analysis using Near Infrared Absorption Spectroscopy. Abstract Progress Report No. 2-3, March 31, 1999 The Home Automation and Healthcare Consortium Noninvasive Blood Glucose Analysis using Near Infrared Absorption Spectroscopy Prof. Kamal Youcef-Toumi Principal Investigator

More information

Energy-saving policy and standard research for solid-state lighting in the United States

Energy-saving policy and standard research for solid-state lighting in the United States Interview Energy-saving policy and standard research for solid-state lighting in the United States [Translation from Synthesiology, Vol.2, No.2, p.170-175 (2009)] When Dr. Yoshi Ohno, who engages in the

More information

ALYA K S-FX LUX 24-MONTH-GUARANTEE LED K* AVAILABLE COLOURS: * CRI = 95 * 6x3 mm ellipse* T E C H

ALYA K S-FX LUX 24-MONTH-GUARANTEE LED K* AVAILABLE COLOURS: * CRI = 95 * 6x3 mm ellipse* T E C H ALYA LED T E C H Medical Device complies to the directive 93/42/CE FARO SPA Ornago (Italy) CRI = 95 * K S-FX LUX for a better colour perception (maximum value = 100) 5.000 K* 6x3 mm ellipse* from 3.000

More information

Motorized Precision Goniometer

Motorized Precision Goniometer Motorized Precision Goniometer Compact, Clear Aperture WT-85 Rotation range 10 Repeatability to 8.7 µrad Load capacity to 2 kg Option: Direct position measurement with angle Combination with WT-100 with

More information

Mechanics and Stages for Light Measurement Applications

Mechanics and Stages for Light Measurement Applications for Light Measurement Applications Sphere Goniometer Detector Mount with Post Stand Two Meter Bench Gonio Photometer Post Mount Stands Bench Systems Rotary Stage Goniometers System and Application Services

More information

DECEMBER 21, 2007 TEST REPORT # REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF

DECEMBER 21, 2007 TEST REPORT # REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF DECEMBER 21, 2007 TEST REPORT #207814 REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF8-025-05.0-L-DV SAMTEC, INC. APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR

More information

Definition and measurement of circadian radiometric quantities

Definition and measurement of circadian radiometric quantities Gall, Dietrich; Bieske, Karin : Definition and measurement of circadian radiometric quantities Inhalt identisch mit: Light and health - non-visual effects : proceedings of the CIE symposium 4 : 3 September

More information

Goniophotometer RiGO 801

Goniophotometer RiGO 801 Goniophotometer RiGO 801 General specification Model series 1400, 1500, 1800, 2000 2018-03-13 TechnoTeam Bildverarbeitung GmbH Werner-von-Siemens-Straße 5 D-98693 Ilmenau http://www.technoteam.de Table

More information

Preferable illuminance under LED lighting for migraineurs aiming to relax

Preferable illuminance under LED lighting for migraineurs aiming to relax Preferable illuminance under LED lighting for migraineurs aiming to relax Akari Kagimoto 1, Shino Okuda 2, Muneto Tatsumoto 3, Katsunori Okajima 4, Koichi Hirata 3 1 Graduate School of Human Life and Science,

More information

STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES

STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES Purpose of this instrument: The Rigaku RU 300 XRD is used for phase analysis of polycrystalline films, characterizing single crystal, and

More information

Supporting Information

Supporting Information Supporting Information An efficient broadband and omnidirectional light-harvesting scheme employing the hierarchical structure based on ZnO nanorod/si 3 N 4 -coated Si microgroove on 5-inch single crystalline

More information

SPECTRAL SIGNATURE ANALYSIS USING A FIELD GONIOMETER MOUNTED SPECTRORADIOMETER

SPECTRAL SIGNATURE ANALYSIS USING A FIELD GONIOMETER MOUNTED SPECTRORADIOMETER SPECTRAL SIGNATURE ANALYSIS USING A FIELD GONIOMETER MOUNTED SPECTRORADIOMETER Michael E. Schaepman, Stefan Sandmeier, Klaus I. Itten, Peter Meyer and Tobias Kellenberger Remote Sensing Laboratories Department

More information

CS294-6 (Fall 2004) Recognizing People, Objects and Actions Lecture: January 27, 2004 Human Visual System

CS294-6 (Fall 2004) Recognizing People, Objects and Actions Lecture: January 27, 2004 Human Visual System CS294-6 (Fall 2004) Recognizing People, Objects and Actions Lecture: January 27, 2004 Human Visual System Lecturer: Jitendra Malik Scribe: Ryan White (Slide: layout of the brain) Facts about the brain:

More information

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial Model: IAQ Indoor PM2.5 -PM2.5 Particulate matter (PM) is a particle pollution, which is produced in a great number of ways that can be classified into either mechanical or chemical processes. Traditionally,

More information

XRDUG Session II Edward Laitila 2/7/2009

XRDUG Session II Edward Laitila 2/7/2009 XRDUG Session II Edward Laitila 2/7/2009 DMSNT-Software and Computer Basic Information: XRDUG SESSION II DMS-NT Software: All bold words in this handout and contained in the operation manual refer to actual

More information

Custom-Made Products / Scientific Research Instruments

Custom-Made Products / Scientific Research Instruments Synchrotron Radiation Instruments Double Crystal Monochromator A double crystal monochromator is an instrument that extracts light of a specific wavelength using crystal diffraction. Light of various wavelengths

More information

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS THOMAS R. WATKINS, O. BURL CAVIN, CAMDEN R. HUBBARD, BETH MATLOCK, AND ROGER

More information

SpiderX. Portable Residual Stress X-Ray Diffractometer.

SpiderX. Portable Residual Stress X-Ray Diffractometer. Portable Residual Stress X-Ray Diffractometer www.gnr.it About SpiderX GNR Analytical Instrument offers equipment based on X-Ray Diffraction to measure residual stress state and retained austenite content.

More information

Agilent 1220 Infinity LC System Performance Specifications

Agilent 1220 Infinity LC System Performance Specifications IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance

More information

Verified. Learning. Their. Candidate. to Gauge. Candidate Course. Page 1

Verified. Learning. Their. Candidate. to Gauge. Candidate Course. Page 1 Coach s Review Assessment of Completion Module 1 Light Lighting Overview Cidate understs the WIIFM, How to Gauge Their Progress the Course Duration. Cidate understs the Principles, Practices, ett al of

More information

DC Unbalance Tolerance Testing in PSE s

DC Unbalance Tolerance Testing in PSE s The PoE Impairment Much like cable attenuation, alien crosstalk, and impedance mismatches present physical layer impairments to packet traffic on 10/100/1000Base-T links, Power-over-Ethernet (PoE) also

More information

LED signalling luminaires / Lisu Series

LED signalling luminaires / Lisu Series / Lisu Series www.daisalux.com 1 Rectangular shape without a projection device and which has not been submitted to design convertions. It takes its aesthetics from a general monochromatic appearance through

More information

Solar Illumination Study

Solar Illumination Study Solar Illumination Study INTRODUCTION The angle of the sun in the sky relative to the horizon (vertical angle) changes throughout the day as the sun traverses from east to west. And the angle that the

More information

LIGHT, MOOD AND PERFORMANCE AT SCHOOL:- TRIPHOSPHOR PHASE #3

LIGHT, MOOD AND PERFORMANCE AT SCHOOL:- TRIPHOSPHOR PHASE #3 LIGHT, MOOD AND PERFORMANCE AT SCHOOL:- TRIPHOSPHOR PHASE #3 For: The Educational Facility Research Group DET/DPWS (NSW) by Robert Samuels Faculty of the Built Environment UNSW November, 2000 CONTENTS

More information

Prospective Design Implications of Recent Findings in Photobiology

Prospective Design Implications of Recent Findings in Photobiology Prospective Design Implications of Recent Findings in Photobiology May 13, 2009 Velux Daylight Symposium 2009 Prof. Marilyne Andersen Building Technology Program, MIT Department of Architecture work conducted

More information

Lighting in Flux. Peter R. Boyce PhD.

Lighting in Flux. Peter R. Boyce PhD. Lighting in Flux Peter R. Boyce PhD. The Past For many decades, general lighting practice has been founded on: Two objectives good visual performance without discomfort Two systems of measurement photometry

More information

Quantitative Radiometric Assessment of Neonatal Phototherapy Units used in the Treatment of Hyperbilirubinaemia

Quantitative Radiometric Assessment of Neonatal Phototherapy Units used in the Treatment of Hyperbilirubinaemia Quantitative Radiometric Assessment of Neonatal Phototherapy Units used in the Treatment of Hyperbilirubinaemia Michael Towey, Tom Cantwell* Dept. of Medical Physics and Bioengineering, Portiuncula Hospital

More information

ILLUMINATION SUMMARY. Field A S10 EQUIPMENT LIST FOR AREAS SHOWN GUARANTEED PERFORMANCE. North Tract Arlington County, VA

ILLUMINATION SUMMARY. Field A S10 EQUIPMENT LIST FOR AREAS SHOWN GUARANTEED PERFORMANCE. North Tract Arlington County, VA QTY LOCATION SIZE THIS GRID 1 S1 55' -7' ' 1500W MZ 5 5 0 1 S2.' - ' 1500W MZ 6 6 0 1 S3 55.5' -6' 49.5' 1500W MZ 9 5 4 1 S8 ' - 43.5' 1500W MZ 4 4 0 1 S9 43.5' - 43.5' 1500W MZ 6 6 0 1 S10 43.5' - 43.5'

More information

Biocard. 1. Troponin I

Biocard.  1. Troponin I Biocard http://www.anibiotech.fi Biocard Quant Reader is a quantitative desktop reader for all Biocard rapid cardiac tests: Troponin I, Myoglobin, CRP, hscrp, MPO and CK-MB. It has a embedded printer and

More information

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations. Lighting HID NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE RATED FLOODLIGHT Applications Powerful, efficient weatherproof lighting for medium and large areas such as: Pulp and paper mills Processing plants

More information

A low magnification SEM image of the fabricated 2 2 ZnO based triode array is

A low magnification SEM image of the fabricated 2 2 ZnO based triode array is Chapter 6 Characteristics of Field Emission Triode 6.1 Planar Gated Field Emission Triode 6.1.1 Structural and Electrical Analysis A low magnification SEM image of the fabricated 2 2 ZnO based triode array

More information

Certificate of Accreditation to ISO/IEC 17025:2005

Certificate of Accreditation to ISO/IEC 17025:2005 United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200454-0 National Standards of Puerto Rico Rio Piedras,

More information

EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS

EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS It is generally accepted that proper use of indoor tanning methods may be safer for the tanner than the uncontrolled environment of outdoor tanning. However,

More information

11/18/13 ECG SIGNAL ACQUISITION HARDWARE DESIGN. Origin of Bioelectric Signals

11/18/13 ECG SIGNAL ACQUISITION HARDWARE DESIGN. Origin of Bioelectric Signals ECG SIGNAL ACQUISITION HARDWARE DESIGN Origin of Bioelectric Signals 1 Cell membrane, channel proteins Electrical and chemical gradients at the semi-permeable cell membrane As a result, we get a membrane

More information

Human Centric Lighting

Human Centric Lighting Human Centric Lighting Daylight Related Metrics as prerequisite for assessment of light quality and for lighting design Dieter Lang OSRAM GmbH Light Affects Humans Light is Vision Brightness Information

More information

LINESCAPES SYSTEM. Made in Italy

LINESCAPES SYSTEM. Made in Italy LINESCAPES SYSTEM LINESCAPES SYSTEM Made in Italy 03 Linescapes is a modular system that is completely changing the approach to high performance diffused direct and indirect lighting. The singular modules

More information

Market Acceptance Of Screwbase Compact Fluorescent Lamps (CFLs)

Market Acceptance Of Screwbase Compact Fluorescent Lamps (CFLs) Market Acceptance Of Screwbase Compact Fluorescent Lamps (CFLs) Lighting Research Center Rensselaer Polytechnic Institute Sponsors: US Environmental Protection Agency US Department of Energy February 2004

More information

Development of a Goniometer with Nanoradian Accuracy

Development of a Goniometer with Nanoradian Accuracy Development of a Goniometer with Nanoradian Accuracy Basil Blank, Thomas Kupp, Eric Johnson, Alex Deyhim, Chi-Chang Kao*, Wolfgang Caliebe*, Gary Navrotski** Abstract Advanced Design Consulting, Inc. 126

More information

2. METHODS. 2.1 Apparatus

2. METHODS. 2.1 Apparatus Pupillary light reflex associated with melanopsin and cone photorecetors Sei-ichi Tsujimura, 1 Katsunori Okajima, 2 1 Faculty of Sciences and Engineering, Kagoshima University, Japan 2 Faculty of Environment

More information

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer HI 903 Karl Fischer Volumetric Titrator Measures 100 ppm to 100% water content Precision titrant delivery system 40,000 step, piston dosing pump Accurate to 0.1% Delivers as little as 0.125 µl of titrant

More information

Descriptions of NDT Projects Fall 2004 October 31, 2004

Descriptions of NDT Projects Fall 2004 October 31, 2004 Descriptions of NDT Projects Fall 2004 October 31, 2004 Introduction There are two separate NDT labs in Magister: ULTRA for ultrasound and EDDY for eddy current. Both labs are equipped with mechanical

More information

A new geometric and mechanical verification device for medical LINACs

A new geometric and mechanical verification device for medical LINACs JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 2, SPRING 2002 A new geometric and mechanical verification device for medical LINACs Keith T. Welsh,* Robert A. Wlodarczyk, and L. E. Reinstein

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

Move on from. based treatment

Move on from. based treatment Product class Test items Diseases Tn-l CK-MB Myoglobin Thrombosis hs-crp Cardiovascular Inflammation PSA Prostate cancer AFP Liver cancer CEA Colorectal cancer Microalbumin HbA1c Cortisol Metabolism Total

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 37-013 GARD Users Manual March 2005 Manual No. 37-013-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective

More information

Supplementary Figure 1. EL spectral characteristics. (a)

Supplementary Figure 1. EL spectral characteristics. (a) Supplementary Figure 1. EL spectral characteristics. (a) Angular dependence of normalized light intensity at 540 nm according to ZnO layers; Lambertian emission pattern (black square), ZnO-F (red circle),

More information

Acceptance testing of a large aperture dynamic wavefront sensor

Acceptance testing of a large aperture dynamic wavefront sensor Acceptance testing of a large aperture dynamic wavefront sensor David J. Fischer*, Alan Wertheimer, Laurie Hill Eastman Kodak Company, 1447 St. Paul St, Rochester, NY 14653 ABSTRACT A large aperture dynamic

More information

KRUT SYSTEMS LLC PRODUCT CATALOG

KRUT SYSTEMS LLC PRODUCT CATALOG KRUT SYSTEMS LLC PRODUCT CATALOG www.krut-led.com KRUT SYSTEMS LLC COMPANY PROFILE Krut Systems LLC is an LED lighting company catering to a wide range of industrial and commercial customers, and customers

More information

Shining a on restoration. Introducing first-of-its-kind Lares Fluoresce HD dual wavelength technology

Shining a on restoration. Introducing first-of-its-kind Lares Fluoresce HD dual wavelength technology Shining a on restoration Introducing first-of-its-kind Lares Fluoresce HD dual wavelength technology One handpiece. Two lights. Limitless possibility. Using innovative dual wavelengths, Fluoresce HD revolutionizes

More information

Filament Fusion Splicing Workstation

Filament Fusion Splicing Workstation FFS-2000 Filament Fusion Splicing Workstation An Integrated System for Production and Specialty Fiber Splicing The FFS-2000 System The FFS-2000 is a complete workstation with all fusion splicing procedures

More information

DO LIGHT-EMITTING DIODE CAP LAMPS ENABLE IMPROVEMENTS IN MINER SAFETY?

DO LIGHT-EMITTING DIODE CAP LAMPS ENABLE IMPROVEMENTS IN MINER SAFETY? DO LIGHT-EMITTING DIODE CAP LAMPS ENABLE IMPROVEMENTS IN MINER SAFETY? J. Sammarco, NIOSH, Pittsburgh, PA M. A. Reyes, NIOSH, Pittsburgh, PA S. Gallagher, NIOSH, Pittsburgh, PA ABSTRACT Proper illumination

More information

Let there be light. The benefits of natural sunlight. KenkoLight

Let there be light. The benefits of natural sunlight. KenkoLight Let there be light. The benefits of natural sunlight KenkoLight Brighten your day. Human beings weren t meant to be indoors all the time. Why? Because sunlight is good for us, physically and mentally.

More information

ON A MECHATRONIC SYSTEM TO DETERMINE DYNAMIC PARAMETERS OF THE HUMAN LIMB DURING LOCOMOTION USED FOR ARTIFICIAL MUSCLES AND IMPLANT DESIGN

ON A MECHATRONIC SYSTEM TO DETERMINE DYNAMIC PARAMETERS OF THE HUMAN LIMB DURING LOCOMOTION USED FOR ARTIFICIAL MUSCLES AND IMPLANT DESIGN 6th International DAAAM Baltic Conference INDUSTRIAL ENGINEERING 24-26 April 2008, Tallinn, Estonia ON A MECHATRONIC SYSTEM TO DETERMINE DYNAMIC PARAMETERS OF THE HUMAN LIMB DURING LOCOMOTION USED FOR

More information

S M A R T. tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free. Revolution in Diagnostics

S M A R T. tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free. Revolution in Diagnostics S M A R T tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free Revolution in Diagnostics Conventional Diagnosis Patient visits the lab's local sample

More information

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE PAK BULLET TRAIN (PBT) JFET 22(2) (2015) 39-44 Journal of Faculty of Engineering & Technology journal homepage: www.pu.edu.pk/journals/index.php/jfet/index DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH

More information

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer Audiometer AA-MC Ideal for clinical practice in otolaryngology clinic Space saving is achieved with a width of about 350 mm Easy operation with touch panel Audiogram can be printed by built-in printer

More information

Nail salon, professional-use only,

Nail salon, professional-use only, New Studies Examine Safety of UV Curing for Fingernail Coatings Feature By Doug Schoon Nail salon, professional-use only, UV artificial nail-curing lamps were recently evaluated in two independent studies

More information

Perceptual Learning of Categorical Colour Constancy, and the Role of Illuminant Familiarity

Perceptual Learning of Categorical Colour Constancy, and the Role of Illuminant Familiarity Perceptual Learning of Categorical Colour Constancy, and the Role of Illuminant Familiarity J. A. Richardson and I. Davies Department of Psychology, University of Surrey, Guildford GU2 5XH, Surrey, United

More information

RiGO801 Laboratory Requirements

RiGO801 Laboratory Requirements RiGO801 Laboratory Requirements 2015-11-25 Air Conditioning According to EN 13032 1 and LM-79-08 the temperature in the environment of the DUT needs to be 25 C +/- 1 C during the measurement. EN 13032-4

More information

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Radiation Safety Characteristics of the NOMAD Portable X-ray System Radiation Safety Characteristics of the NOMAD Portable X-ray System D. Clark Turner 1, Donald K. Kloos 1, Robert Morton 2 1 ARIBA X-Ray, Inc., 754 South 400 East, Orem, UT 84097 USA, www.aribaxray.com

More information

Performance Characteristics of a New Single-Sample Freezing Point Depression Osmometer

Performance Characteristics of a New Single-Sample Freezing Point Depression Osmometer AACC, July 2007 Performance Characteristics of a New Single-Sample Freezing Point Depression Osmometer E. Garry, M. Pesta, N. Zampa Advanced Instruments, Inc., Norwood, MA 02062 AbstracT The Advanced Model

More information

The Perception of Static Colored Noise: Detection and Masking Described by CIE94

The Perception of Static Colored Noise: Detection and Masking Described by CIE94 The Perception of Static Colored Noise: Detection and Masking Described by CIE94 Marcel P. Lucassen, 1 * Piet Bijl, 1 Jolanda Roelofsen 2 1 TNO Human Factors, Soesterberg, The Netherlands 2 Cognitive Psychology,

More information

Multi-Channel Film Dosimetry and Gamma Map Verification

Multi-Channel Film Dosimetry and Gamma Map Verification Multi-Channel Film Dosimetry and Gamma Map Verification Micke A International Specialty Products Ashland proprietary technology, patents pending Single Channel Film Dosimetry Calibration Curve X=R R ave

More information